2019.08.09 NRCS 100% CD DRAWINGS.pdf

PDF 9 MB Posted

Attached to
Region 8 Indefinite Delivery Indefinite Quantity (IDIQ) Multiple Award Construction Contract (MACC)
Solicitation number
47PJ0020R0064
Issued by

About this file

This document provides details for a solicitation seeking proposals for an indefinite delivery indefinite quantity multiple award construction contract to provide construction services in Colorado, Montana, Utah, North Dakota, South Dakota, and Wyoming. The solicitation is for a total small business set-aside. The contract will have a one year base period and four one-year options periods and will be awarded to multiple awardees. Construction services will include new construction, renovations, repairs, alterations, and lease construction for federal buildings managed by the General Services Administration Public Buildings Service Region 8. Proposals are due by the date specified in the attached solicitation notice. The contract has an estimated value of $500 million over the five-year period.

View the file

Other files

File Type Posted
Revised 4 R8 MACC IDIQ Solicitation.docx DOCX document
Solicitation Amendment 47PJ0020R0064_0001 (1).pdf PDF
R8 IDIQ Prebid RFI Log - dated 5-6.pdf PDF
Revised IDIQquestionnaire.pdf PDF
Revised 47PJ0020R0064pdf.pdf PDF
Bid Sheet Template -.xls XLS spreadsheet
R8 IDIQ RFI Technical Questions.pdf PDF
Revised 3 R8 MACC IDIQ Solicitation.docx DOCX document
R8 MACC IDIQ RFI 4 03232020.docx DOCX document
R8 MACC IDIQ 3.docx DOCX document
Revised 03122020 R8 MACC IDIQ Solicitation.docx DOCX document
Revised 03122020 R8 MACC IDIQ - Reps and Certs.docx DOCX document
R8 MACC IDIQ RFI 2 .pdf PDF
Revised 2 R8 MACC IDIQ Solicitation.docx DOCX document
R8 MACC IDIQ RFIOne.docx DOCX document
Seed Project.pdf PDF
2019.08.09 NRCS 100% CD Specifications.pdf PDF
Vendor Fitness Determination .pdf PDF
Revised R8 MACC IDIQ Agreement.docx DOCX document
Revised 47PJ0020R0064.pdf PDF
Revised R8 MACC IDIQ Solicitation.docx DOCX document
IDIQquestionnaire.pdf PDF
R8 MACC IDIQ - Reps and Certs.docx DOCX document
USR_v2.1_6.8.18.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

ANDERSON HALLAS

ARCHITECTS, PC

SHEET OF

PROPERTY OF THE UNITED STATES GOVERNMENT

COPYING, DISSEMINATION, OR DISTRIBUTION OF THESE DRAWINGS,

PLANS, OR SPECIFICATIONS TO UNAUTHORIZED USERS

IS PROHIBITED

Do Not Remove This Notice Properly Destroy Documents When No Longer Needed

GENERAL SERVICES ADMINISTRATION ~ DENVER FEDERAL CENTER ~ BUILDING 56

/8

/2

:0

:0

P

M

1 50

7/25/2019

BUILDING 56 - 2ND FLOOR NRCS CONSOLIDATION

G 010

100% CD ISSUE JULY 25, 2019

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

GENERAL NOTES

1. DO NOT SCALE DRAWINGS

2. ALL WORK TO BE PERFORMED TO APPLICABLE BUILDING CODES.

3. ALL DIMENSIONS ARE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED. ALL DIMENSIONS INDICATING

REQUIRED CLEARANCES ARE TO FACE OF FINISH UNLESS OTHERWISE NOTED.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIM OR HERSELF WITH THE CONTRACT

DOCUMENTS, VERIFYING FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. CONTRACTOR SHALL NOTIFY GOVERNMENT & ARCHITECT IN WRITING OF ANY DISCREPANCY WITHIN THE CONTRACT DOCUMENTS AND REQUEST

CLARIFICATION PRIOR TO PROCEEDING WITH CONSTRUCTION.

5. SHOULD THERE BE ANY QUESTIONS CONCERNING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE GOVERNMENT & ARCHITECT PRIOR TO PROCEEDING WITH THE WORK, OR RELATED WORK IN QUESTION.

6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, SCHEDULE, AND DEADLINES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADVISING THE GOVERNMENT & ARCHITECT OF ALL ITEMS REQUIRING A LONG LEAD TIME UPON NOTICE TO PROCEED THAT WILL AFFECT THE SCHEDULE, AND SHALL SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR THE ITEMS IN QUESTION TO THE

GOVERNMENT.

7. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. THE CONTRACTOR SHALL FURNISH TO THE GOVERNMENT ALL WARRANTIES AND GUARANTEES REQUIRED AT THE CONCLUSION OF THE PROJECT.

8. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING TO THE GOVERNMENT & ARCHITECT WITHIN 14 DAYS OF NOTICE TO PROCEED, AND BE ACCOMPANIED WITH THE ALTERNATIVE PRODUCT INFORMATION. SUBSTITUTIONS WILL BE CONSIDERED ONLY IF IT DOES NOT

SACRIFICE QUALITY, APPEARANCE, DELIVERY TIME, OR FUNCTION.

9. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HOOK UPS / UTILITY CONNECTIONS, ETC. TO TEMPORARY TRAILERS.

A4.0

A8.0

ROOM

250 SF

A9.0

A5.0

N

FIRST FLOOR

100'-0"

5 1 6 75

KEY

NOTE

WALL

TYPE

WINDOW

TYPE/NUMBER

DOOR

NUMBER

ELEVATION MARK NORTH ARROW

DETAIL REFERENCE

BUILDING SECTION

EXTERIOR

ELEVATION

INTERIOR

ELEVATION

ROOM

TAG

SYMBOLS

PROJECT TEAM

Owner

General Services Administration, Region 8 DFC Building 41 Denver, CO 80225 303.236.0855 Ben Reko, Project Manager

720.412.2812 c benjamin.reko@gsa.gov

Architect

Anderson Hallas Architects, PC 715 14th St.

Golden, CO 80401 P: 303-278-4378 F: 303-278-0521 Principal in Charge: Dave Anderson Project Manager: Rebecca Silva email: rebeccasilva@andarch.com

Mechanical / Plumbing Engineer

360 Engineering 1600 Jackson Street, Suite 360 Golden, CO 80401 303.940.2050 Denise Dehle ddihle@360eng.com Travis Menard

720.619.1545 c tmenard@360eng.com

Electrical Engineer

AE Design 1900 Wazee Street #350 Denver, CO 80202 720.266.4755 Jon Brooks jbrooks@aedesign-inc.com Patrick Durham

303.444.1951 c pdurham@aedesign-inc.com

Parametrix, Inc.

J. R. Anzer, Cost Estimator 7186 South Highland Drive Salt Lake City, Utah 84121 Phone: 801-733-5900 Fax: 801-733-5500

Cost Estimator

Veritas Fire Engineer 12364 W. Alameda Pkwy Suite 135 Lakewood, CO 80228 Phone: 303.985.3300 Toll-Free: 1.866.985.2050 Fax: 303.985.5594 Kerry Madigan Kerry@veritasfire.com Bryan Echelberger Bryan@veritasfire.com

Protection Fire Engineer

G

LS

I A S M E

EP

EL

P

FA

FS

TC

TA

TE

SEC

GENERAL

LIFE SAFETY

INTERIORS

ARCHITECTURAL

STRUCTURAL

MECHANICAL/HVAC

ELECTRICAL

ELECTRICAL - POWER

ELECTRICAL - LIGHTING

PLUMBING

FIRE ALARM

FIRE SAFETY

TELECOMMUNCATIONS

AUDIO VISUAL

AUDIO VISUAL -

INFRASTRUCTURE

SECURTY

0 00 1 00 2 00 3 00 4 00 5 00 6 00 7 00 8 00 9 00

GENERAL INFORMATION

FLOOR PLANS

ELEVATIONS - EXTERIOR

SECTIONS

ENLARGED DWGS

DETAILS

SCHEDULES

REFLECTED CEILING PLAN (RCP)

FINISH PLANS

ELEVATIONS - INTERIOR

DISIPLINE INDEX

CONTEXT INDEX

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:0

P

M

G 0 02 2 50

DCA/ RS

DAM / LB 07/25/2019

22X34

2ND FLOOR

INDEX & GENERAL INFORMATION

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

OD OUTSIDE DIAMETER

OH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OSB ORIENTED STRAND BOARD

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLUMB PLUMBING

PT PAINT

PTD PAINTED

PWD PLYWOOD

QT QUARRY TILE

RAD RADIUS

RB RUBBER BASE

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

REF REFER TO or REFERENCE

REINF REINFORCED

RELOC RELOCATE(D)

REQ REQUIRED

REV REVISE, REVISED or REVISION

RM ROOM

RO ROUGH OPENING

RS ROUGH SAWN

(S) SEALANT

S SOUTH

SCHED SCHEDULE

SF SQUARE FEET

SHTG SHEATHING

SIM SIMILAR

SL SHEET LINOLEUM

SOG SLAB ON GRADE

SPEC SPECIFICATION(S)

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

STL STEEL

STN STAIN

STRUC STRUCTURE or STRUCTURAL

(T) TEMPERED

T&G TONGUE AND GROOVE

T.O. TOP OF

TD THRESHOLD

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VIF VERIFY IN FIELD

VIN VINYL

VTR VENT THROUGH ROOF

W WEST

W/ WITH

W/O WITHOUT

WD WOOD

WIN WINDOW

EXT EXTERIOR

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FIN FINISH(ED)

FIXT FIXTURE

FLR FLOOR(ING)

FO FACE OF

FP FIRE PROTECTION

FRP FIBERGLASS REINFORCED PANEL(ING)

FT FEET

FTG FOOTING

FURR FURRING

GA GAUGE OR GYPSUM ASSOCIATION

GALV GLAVANIZED

GC GENERAL CONTRACTOR

GD GRADE

GL GLASS or GLAZING

GND GROUND

GWB GYPSUM WALLBOARD

HM HOLLOW METAL

HAZMAT HAZARDOUS MATERIAL

HDR HEADER

HDW HARDWARE

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION and AIR

CONDITIONING

IBC INTERNATIONAL BUILDING CODE

ID INSIDE DIAMETER

INFO INFORMATION

INS INSULATION or INSULATED

INT INTERIOR

JT JOINT

LAV LAVATORY

LIN LINOLEUM

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MEP MECHANICAL, ELECTRICAL and

PLUMBING

MFG MANUFACTURING

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

<N> NEW

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO. NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

# POUND(S) or NUMBER

& AND

< ANGLE

@ AT

A/V AUDIO VISUAL

ABV ABOVE

ACM ASBESTOS CONTAINING MATERIAL

ACT ACCOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDENDUM

ADJ ADJACENT or ADJUSTABLE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AL ALUMINUM

ALT ALTERNATE

APPROX APPROXIMATE(LY)

ARCH ARCHITECTURAL

ASPH ASPHALT

B.O. BOTTOM OF

BLDG BUILDING

BLKG BLOCKING

BR BACKER ROD

BTWN BETWEEN

CAB CABINET

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CT CERAMIC TILE

CTBB CEMENTITIOUS TILE BACKER BOARD

CTR CENTER

DBL DOUBLE

DEMO DEMOLITION

DET DETAIL

DF DRINKING FOUNTAIN

DIAM DIAMETER

DIM DIMENSION

DN DOWN

DS DOWNSPOUT

<E> EXISTING

E EAST

EA EACH

EG FOR EXAMPLE

ELEC ELECTRICAL

ELEV ELEVATION

EMER EMERGENCY

ENGR ENGINEER

EQ EQUAL

EQP EQUIPMENT

ETR EXISTING TO REMAIN

INDEX

ABBREVIATIONS

SHEET SUB. SHEET Sheet Name

GENERAL

1 01 COVER SHEET

2 G 0 02 INDEX & GENERAL INFORMATION

3 G 0 03 CODE AND EGRESS INFORMATION

4 G 0 04 WALL TYPES CEILING TYPES

STATE VICINITY MAP CITY LOCATION MAP

N N

NTS NTS

CITY LOCATION

MAP PROJECT AREA:

DENVER FEDERAL CENTER

PROJECT AREA STREET MAP

N

NTS

K

IP

L

IN

G S

T R

E E

T

WEST 6TH AVE.

PROJECT AREA:

DENVER FEDERAL CENTER

BUILDING 56

6TH STEET

DENVER, COLORADO 80215

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

ARCHITECTURAL

5 A 4 01 ENLARGED DEMO FLOOR PLAN - PART 'A'

6 A 4 02 ENLARGED DEMO FLOOR PLAN - PART 'B'

7 A 4 03 ENLARGED NEW FLOOR PLAN - PART 'A'

8 A 4 04 ENLARGED NEW FLOOR PLAN - PART 'B'

9 A 5 01 CASEWORK DETAILS

10 A 6 01 DOOR AND WINDOW SCHEDULES

11 A 6 02 ROOM FINISH SCHEDULE AND DETAILS

12 A 7 01 ENLARGED DEMO REFLECTED CEILING PLAN - PART 'A'

13 A 7 02 ENLARGED DEMO REFLECTED CEILING PLANS - PART 'B'

14 A 7 03 ENLARGED NEW REFLECTED CEILING PLAN - PART 'A'

15 A 7 04 ENLARGED NEW REFLECTED CEILING PLAN - PART 'B'

16 A 9 01 INTERIOR ELEVATIONS - OPEN OFFICE

MECHANICAL

17 M 0 MECHANICAL COVER SHEET

18 MD 1 MECHANICAL DEMO PLAN PART A

19 M 1 MECHANICAL FLOOR PLAN PART A

20 M 2 MECHANICAL FLOOR PLAN PART B

PLUMBING

21 P 1 PLUMBING FLOOR PLAN

ELECTRICAL

22 E 0 01 ELECTRICAL COVER SHEET

23 E 0 00 ELECTRICAL COVER SHEET

24 ED 2 01 ELECTRICAL DEMO POWER PLAN-AREA A

25 ED 2 02 ELECTRICAL DEMO POWER PLAN-AREA B

26 ED 2 03 ELECTRICAL DEMO POWER PLAN-AREA C

27 ED 3 01 ELECTRICAL DEMO LIGHTING PLAN-AREA A

28 ED 3 02 ELECTRICAL DEMO LIGHTING PLAN-AREA B

29 ED 3 03 ELECTRICAL DEMO LIGHTING PLAN-AREA C

30 E 2 01 ELECTRICAL POWER PLAN-AREA A

31 E 2 02 ELECTRICAL POWER PLAN-AREA B

32 E 2 03 ELECTICAL POWER PLAN-AREA C

33 E 3 01 ELECTRICAL LIGHTING PLAN-AREA A

34 E 2 04 ELECTRICAL POWER PLAN- AREA D

35 E 3 02 ELECTRICAL LIGHTING PLAN-AREA B

36 E 3 03 ELECTRICAL LIGHTING PLAN-AREA C

37 E 6 00 ELECTRICAL ONE LINE DIAGRAM

38 E 7 00 ELECTRICAL SCHEDULES

39 E 7 10 ELECTRICAL PANEL SCHEDULES

40 E 7 20 ELECTRICAL PANEL SCHEDULES

FIRE PROTECTION

41 FP 1 01 FP NOTES AND DETAILS

42 FP 1 02 FIRE SPRINKLER DEMO PART-A

43 FP 1 03 FIRE SPRINKLER DEMO PART-B

44 FP 1 04 FIRE SPRINKLER PART-A

45 FP 1 05 FIRE SPRINKLER PART-B

46 FA 1 01 FA NOTES AND DETAILS

47 FAD 1 02 FIRE ALARM DEMO PART-A

48 FAD 1 03 FIRE ALARM DEMO PART-B

49 FA 1 04 FIRE ALARM PART-A

50 FA 1 05 FIRE ALARM PART-B

MARK DATE DESCRIPTION

ALTERNATES:

1. ACOUSTIC WALL PANELS PER SHEET A 9 01.

FIRE SAFETY/EGRESS LEGEND

- EGRESS DOOR W/ EXIT SIGNAGE

- EGRESS PATH

- ASSUMED (E) 2HR RATED PARTITION

- DIRECTION OF EGRESS TRAVEL

- FIRE EXTINGUISHER CABINET

- EXIT SIGNAGE

- EMERGENCY LIGHT

FEC

- AREA OF WORK

AREA OF WORK

~ PARTS 'A' & 'B'

18.1

C

D

E

F

G

H

I

13 14 15 16 17 1816.112.1

STORAGE & IT

WAITING /

RECEPTION

MEETING ROOM 1

MEETING ROOM 2

BREAK ROOM

CLOSET /

STORAGE

N.I.C.

DN

EXISTING MEN'S

RR (N.I.C.)

N.I.C.

EXISTING

WOMEN'S RR

(N.I.C.)

N.I.C.

EXISTING OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. HALL (N.I.C.)

N.I.C.

EXT. COMM /

ELEC. RM. (N.I.C.)

N.I.C.

MECHANICAL

ECS OFFICE

OPEN OFFICE

OPEN OFFICE

STATE CONSERV.

OFFICE

PROGRAMS

OFFICE

SNOW OFFICE

PHONE BOOTH

PHONE BOOTH

OPEN OFFICE

CLOSET

SOILS OFFICE

MGT & STRAT.

OFFICE

ENG. OFFICE

PHONE BOOTH

PHONE BOOTH

JEFFCO STG

MAX EXIT

ACCESS TRAVEL

DISTANCE: 96' - 0"

91'-5"

TRAVEL

DISTANCE

BUILDING CODE ANALYSIS

Code analysis is based on the 2015 International Building Code, and the 2015 International Existing Building Code. Refer to Mechanical, Plumbing, Electrical & Fire Protection sheets for additional information.

Date: 02.15.2019 Analysis By: RAS Project Number: 2017360 Project Name: NRCS Consolidation Address: Building 56 6th Street

Denver, CO 80255

SCOPE OF WORK:

This project is a tenant finish to a small portion of the 2nd floor of Building 56, located in the Federal Center. The scope includes minor wall reconfiguration, new interior finishes, a new break room, and minor reconfiguration of mechanical, electrical and fire protection systems.

No work to the building envelope is included.

PROJECT OCCUPANCY: B

CONSTRUCTION TYPE:

Type IIB, with a fully automatic NFPA 13 sprinkler system

PROJECT AREA: 9750sf

OCCUPANT LOAD:

Business(100sf/person): 8265sf = 83 Mechanical/ Support (300sf/person): 810sf = 3 Total Occupant Load: 86

BUILDING HEIGHT AND NUMBER OF STORIES: Unchanged

BUILDING AREA: Unchanged

FIRE PROTECTION:

Existing fire sprinkler system to be upgraded to comply with Section 903.

Portable fire extinguishers required per section 906, and located per GSA P100 in mechanical, electrical, IT and Break Rooms. Contractor to verify existing extinguishers are present, code compliant, and in working order. If not, replace.

Existing fire alarm system to be upgraded to comply with Section 907.

EGRESS:

Egress width: 32" + 64" provided. Required width = 32" min.

Two exits provided. - Required # = 2

Exit Access Travel Distance: 96' max. provided. 300' max. required.

Common Path of Egress Travel Distance: 58' max. provided. 100' max. provided.

PLUMBING FIXTURE COUNT: unchanged

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:1

P

M

G 0 03 3 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

CODE AND EGRESS INFORMATION

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

2nd FLOOR KEY PLAN

N

3/32" = 1'-0"

EGRESS - SECOND LEVEL FLOOR PLAN - PART 'A' AND 'B'

AREA OF WORK

AREA OF WORK

N

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

MATCH LINE

MARK DATE DESCRIPTION

18 GA. BOTTOM TRACK

~ ANCHOR WITH

POWER ACTUATED

FASTENERS AT 24" O.C.

RESILIENT BASE, RE:

ROOM FINISH SCHEDULE

FOR LOCATION

18 GA. METAL STUDS

AT 24" O.C.5/8" GYPSUM BOARD AT

EACH FACE OF STUD

18 GA. METAL TOP TRACK

~ ANCHOR TO EXISTING

CEILING TRACK, SET IN

BED OF SEALANT (AT

TRACK LOCATION ONLY)

MODIFY <E> CEILING TILE

TO ACCOMMODATE NEW

WALL, TILE SHALL LAY

LEVEL AND

UNINTERRUPTED

PROVIDE METAL L-BEAD,

TYP EACH SIDE OF WALL

<E> CEILING TILE

PROVIDE METAL STUD

DIAGONAL BRACING TO

STRUCTURE AT 48" O.C.,

ALTERNATE DIRECTION

PROVIDE ACOUSTIC

BATT INSULATION FROM

FLOOR TO CEILING

ABOVE BETWEEN

STUDS, FULL DEPTH OF

WALL

<E> SUPPORT

HANGERS TO REMAIN

SECTION

3-5/8" x 18 GA. METAL

STUDS AT 16" O.C. WITH

18GA. TOP AND BOTTOM

TRACK

5/8" GYPSUM BOARD AT

EACH FACE OF STUD

PLANPROVIDE ACOUSTIC BATT INSULATION

FROM FLOOR TO CEILING ABOVE

BETWEEN STUDS, FULL DEPTH OF

WALL

WALL

TYPE

WALL

TYPE

1.1 = SAME AS WALL TYPE WT1, WALL CONSTRUCTED WITH 6" 18GA.

METAL STUDS AT 16" O.C. WITH TOP AND BOTTOM TRACKS

UN-

RATED

UN-

RATED

WALL

TYPE

3.1 = SAME AS WALL TYPE WT1, WALL ~ NO ACOUSTIC BATT

INSULATION

UN-

RATED

INSTALL 12" MIN. ACOUSTIC

BATT INSULATION OVER

<N> AND <E> WALL

LOCATIONS TO A MINIMUM

OF 4-0" FROM WALL, EACH

SIDE.

WALL

TYPE

3.0

NOTE: CONTRACTOR TO

VERIFY (E) WALL ASSEMBLY

IN FIELD. NOTIFY ARCHITECT

IF DIFFERENT THAN DRAWN.

3-5/8" x 18 GA. METAL

STUDS AT 16" O.C. WITH

18GA. TOP AND BOTTOM

TRACK

2 LAYERS OF 5/8"

GYPSUM BOARD AT

EACH FACE OF STUD

PLAN

PROVIDE ACOUSTIC BATT INSULATION

FROM FLOOR TO CEILING ABOVE

BETWEEN STUDS, FULL DEPTH OF

WALL

18 GA. BOTTOM TRACK

~ ANCHOR WITH

POWER ACTUATED

FASTENERS AT 24" O.C.

RESILIENT BASE, RE:

ROOM FINISH SCHEDULE

FOR LOCATION

18 GA. METAL STUDS

AT 24" O.C.5/8" GYPSUM BOARD AT

EACH FACE OF STUD

18 GA. METAL TOP TRACK

~ ANCHOR TO CEILING

TRACK, SET IN BED OF

SEALANT (AT TRACK

LOCATION ONLY)

PROVIDE METAL L-BEAD,

TYP EACH SIDE OF WALL

<N> CEILING TILE

PROVIDE METAL STUD

DIAGONAL BRACING TO

STRUCTURE AT 48" O.C.,

ALTERNATE DIRECTION

PROVIDE ACOUSTIC

BATT INSULATION FROM

FLOOR TO CEILING

ABOVE BETWEEN

STUDS, FULL DEPTH OF

WALL

SUPPORT HANGERS

SECTION

INSTALL 12" MIN. ACOUSTIC

BATT INSULATION OVER

<N> AND <E> WALL

LOCATIONS TO A MINIMUM

OF 4-0" FROM WALL, EACH

SIDE.

(E) CMU WALL

(N) RESILIENT FURRING

CHANNELS

PLAN

(N) 5/8" GYPSUM BOARD

WALL

TYPE

2.0UN-

RATED

ASSUMED (E) 3 5/8"

FURRING & INSULATION

2 HR FIRE RATED

UL UL404B

SUSPENDED ACOUSTIC TILE (ACT) ~

MATCH EXISTING ADJACENT CEILING TILE

RE: CEILING PLAN AND ROOM FINISH SCHEDULE

FOR CEILING ELEVATIONS

SUSPENDED SUPPORT HANGERS ~

ATTACH TO STRUCTURE ABOVE AT

EACH INTERSECTIONS OF CROSS TEE'S

SUSPENDED CEILING

CROSS TEE'S ~ NEW TEE'S

TO MATCH ADJACENT <E>

TEE'S

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:1

P

M

G 0 04 4 50

DCA / RS

DAM / LB 04/15/2019

22X34

WALL TYPES CEILING TYPES

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

1 1/2" = 1'-0"

WALL TYPES

1 1/2" = 1'-0"

CEILING TYPE C1 - Typical ACT Ceiling

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

AREA OF

WORK ~ PART

'A'

18.1

G

H

I

J

13 14 15 16 17 1816.112.1

REMOVE <E> FLOORING

<E> FLOORING TO REMAIN

DF1 DF1

DF3

DF3

DF5

1197 1198

11401141

DF7

DF8

DF6

/2

/2

R.O

3' - 2" 15' - 3 5/8"

R.O

3' - 2" 5" 3' - 2" 5"

DF9

/8

STATE

CONSERVATIONIST

DEPUTY

2403 STATE

CONSERVATIONIST

RECEPTION AREA

2405A

HALL WAY

2405B

COMM/ ELEC.

N.I.C.

MEN'S TOILET

NO. 3

N.I.C.

WOMEN'S TOILET

NO. 3

N.I.C.

MAIL ROOM

OFFICE PAS

OFFICE

OPERATIONS

OFFICE

PROGRAMS

OFFICE ECS

OFFICE AREA

OFFICE ADMIN.

OFFICE ADMIN.

OFFICE ADMIN.

N.I.C.

OFFICE ADMIN.

N.I.C.

HALL WAY

N.I.C.

HALL WAY

N.I.C.

EXECUTIVE

LARGE MEETING

ROOM

MATCH LINE

WALL TO BE REMOVED IN ITS

ENTIRETY

DEMO LEGEND

DOOR TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

KEYNOTE TAGXX

XX DOOR TAG - DOOR TO BE

SALVAGED FOR REUSE

MATCH LINE

GENERAL AND SALVAGE NOTES:

1. CAREFULLY REMOVE ALL <E> INTERIOR DOOR LEAVES FOR REINSTALLATION (13 TOTAL DOORS).

2. COORDINATE REMOVAL AND REINSTALLATION OF MISC WALL MOUNTED ITEMS WITH OWNER

3. CONTRACTOR TO COORDINATE REMOVAL/REUSE OF (E) CUBICLES, FURNITURE, & CASEWORK WITH NRCS & GSA

4. REMOVE ALL FLOORING WITHIN AREA. SALVAGE <E> CARPET TO PATCH WHERE WALL REMOVED AT ADJACENT

SPACE TO SOUTH.

5. CAREFULLY REMOVE ALL <E> WINDOW COVERINGS. PROTECT & STORE FOR REINSTALLATION IN SAME LOCATION.

6. ALL <E> EXTERIOR WINDOWS TO REMAIN, PROTECT IN PLACE.

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:4

P

M

A 4 01 5 50

DCA / RS

DAM / LB 04/15/2019

22X34

2nd FLOOR

ENLARGED DEMO FLOOR PLAN - PART 'A'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

2nd FLOOR KEY PLAN

N

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1/8" = 1'-0"

DEMO - SECOND LEVEL FLOOR PLAN - PART 'A'

N

N

DEMO KEYNOTES

Key Value Keynote Text

DF1 REMOVE <E> INTERIOR WINDOW

DF3 <E> FINISHES TO REMAIN

DF5 COORDINATE RELOCATION OF IT EQUIPMENT WITH NRCS IT

STAFF, RE: ELEC.

DF6 REMOVE (E) GWB. THIS SIDE

DF7 REMOVE (E) PORTION OF (E) MASONRY WALL (E) BEAM TO

REMAIN

DF8 (E) SOFFIT TO REMAIN

DF9 (E) COLUMN TO REMAIN

0 8' 16'

C

D

E

F

G

15 16 16.1

DF3

DF3

AREA OF

WORK ~ PART

'B'

FILE/STORAGE

ROOM

PROGRAMS

CLOSET

OFFICE AREA

ECS PLOT AREA

& SUPPORT

SPACE

OFFICE AREA

EXISTING MECH.

EQUIP/FURN

STORAGE PAS

FILE STORAGE

LIBRARY

STAIR

N.I.C.

MATCH LINE

WALL TO BE REMOVED IN ITS

ENTIRETY

DEMO LEGEND

DOOR TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

KEYNOTE TAGXX

XX DOOR TAG - DOOR TO BE

SALVAGED FOR REUSE

MATCH LINE

GENERAL AND SALVAGE NOTES:

1. CAREFULLY REMOVE ALL <E> INTERIOR DOOR LEAVES FOR REINSTALLATION (13 TOTAL DOORS).

2. COORDINATE REMOVAL AND REINSTALLATION OF MISC WALL MOUNTED ITEMS WITH OWNER

3. CONTRACTOR TO COORDINATE REMOVAL/REUSE OF (E) CUBICLES, FURNITURE, & CASEWORK WITH NRCS & GSA

4. REMOVE ALL FLOORING WITHIN AREA. SALVAGE <E> CARPET TO PATCH WHERE WALL REMOVED AT ADJACENT

SPACE TO SOUTH.

5. CAREFULLY REMOVE ALL <E> WINDOW COVERINGS. PROTECT & STORE FOR REINSTALLATION IN SAME LOCATION.

6. ALL <E> EXTERIOR WINDOWS TO REMAIN, PROTECT IN PLACE.

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:4

P

M

A 4 02 6 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

ENLARGED DEMO FLOOR PLAN - PART 'B'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

N

1/8" = 1'-0"

DEMO - SECOND LEVEL FLOOR PLAN - PART 'B'

2nd FLOOR KEY PLAN

N

DEMO KEYNOTES

Key Value Keynote Text

DF3 <E> FINISHES TO REMAIN

R E

F

D W

GENERAL PLAN NOTES

1. REFER TO RCP, MECH, ELEC, AND PLUMBING FOR ADDITIONAL INFORMATION

2. REINSTALL <E> WINDOW COVERINGS IN SAME LOCATION. PROTECT IN PLACE.

TYP. ALL WINDOWS

3. ALL FURNISHINGS AND SYSTEMS FURNITURE BY OWNER CONSULTANT. SHOWN

FOR REFERENCE ONLY.

4. COORDINATE RELOCATION OF IT EQUIPMENT W/ NRCS STAFF. REFER TO

ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.

5. DIMENSIONS TO CL OF DOORS IN (N) WALLS

6. PREP SUB FLOOR FOR <N> FLOORING

18.1

G

H

I

J

13 14 15 16 17 1816.112.1

STORAGE & IT

WAITING /

RECEPTION

MEETING ROOM 1

MEETING ROOM 2

BREAK ROOM

CLOSET /

STORAGE

N.I.C.

DN

EXISTING MEN'S

RR (N.I.C.)

N.I.C.

EXISTING

WOMEN'S RR

(N.I.C.)

N.I.C.

EXISTING OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. HALL (N.I.C.)

N.I.C.

EXT. COMM /

ELEC. RM. (N.I.C.)

N.I.C.

STATE CONSERV.

OFFICE

B

2403A

3 3

3.13.1

SNOW OFFICE

PROGRAMS

OFFICE

JEFFCO STG

OPEN OFFICE

PHONE BOOTH

PHONE BOOTH

NF3

3.1

FIN. TO STUD

36' - 5 3/8" 8' - 1 5/8"

10' - 11 1/4"

H O

L D

/8

F

IN

T O

S T

U D

/4

/8

/8

/8

/8

F

IN

T O

S T

U D

/8

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

COPY/ FILE/

STORAGE

/4

CUBICLE PARTITIONS BY

GSA FURNITURE SUPPLIER

5 5/8" 11' - 1 3/4" 6' - 4 7/8"

ADA CABINET FOR

30" X 48" FRONT

APPROACH

A5 011

A L

IG

N

A4 03

A9 01 45

NF5

NF6

CL

2' - 0"

CL

2' - 0"

CL

2' - 0"

NF2

MATCH LINE

NF2

NF6NF6

6' - 7 5/8" 5' - 10" 2' - 3 5/8"

1' - 11 1/2"

AREA OF

WORK ~ PART

'A'

PHONE BOOTH

PHONE BOOTH

18" DEEP ABA COUNTER

ON BRACKETS, RE: A5 01

A5 01

Sim

A5 01

Sim

(N) WALL, RE: TAG FOR TYPE

PLAN LEGEND

KEYNOTE TAGXX

DOOR TAG

MATCH LINE

2.0 WALL TYPE TAG

XXX

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:5

P

M

A 4 03 7 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

ENLARGED NEW FLOOR PLAN - PART 'A'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017N

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1/8" = 1'-0"

NEW - SECOND LEVEL FLOOR PLAN - PART 'A'

2nd FLOOR KEY PLAN

N

NEW KEYNOTES

Key Value Keynote Text

NF2 PATCH END OF WALL MATCH (E) ADJACENT FINISH

NF4 INFILL (E) OPENING WHERE DOOR WAS REMOVED. MATCH

(E) ADJACENT WALL ASSEMBLY; ASSUMED WALL TYPE 3.

NF6 PATCH/REPAIR EXISTING FLOORING AND CEILING TO

MATCH (E) FINISH WHERE WALL IS REMOVED. USE

SALVAGED CARPET FROM DEMO.

0 8' 16'

1/4" = 1'-0"

ENLARGED PLAN - PHONE BOOTHS

ROOMS 2425 & 2427 SIMILAR

E

F

G

15 16 16.1

MECHANICAL

OPEN OFFICE

ECS OFFICE

OPEN OFFICE

DN

CLOSET

SOILS OFFICE

MGT & STRAT.

OFFICE

ENG. OFFICE

OPEN OFFICE

PHONE BOOTH

PHONE BOOTH

FIN TO STUD

11' - 3 1/2" 6' - 4 7/8"

/8

/8

/8

/2

FIN TO STUD

13' - 10 1/2"

/8

/8

F

IN

T O

S T

U D

/8

PLOTTER/ COPY

ECS &

ENGINEERING

STORAGE

/4

NF4

A4 03

Sim

HOLD

8' - 4"

HOLD

4' - 9 3/8"

A9 013 2

A9 01

A9 01 45

NF5

2' - 1"

2' - 1"

MATCH LINE

ALIGN

AREA OF

WORK ~ PART

'B'

GENERAL PLAN NOTES

1. REFER TO RCP, MECH, ELEC, AND PLUMBING FOR ADDITIONAL INFORMATION

2. REINSTALL <E> WINDOW COVERINGS IN SAME LOCATION. PROTECT IN PLACE.

TYP. ALL WINDOWS

3. ALL FURNISHINGS AND SYSTEMS FURNITURE BY OWNER CONSULTANT. SHOWN

FOR REFERENCE ONLY.

4. COORDINATE RELOCATION OF IT EQUIPMENT W/ NRCS STAFF. REFER TO

ELECTRICAL SHEETS FOR ADDITIONAL INFORMATION.

5. DIMENSIONS TO CL OF DOORS IN (N) WALLS

6. PREP SUB FLOOR FOR <N> FLOORING

(N) WALL, RE: TAG FOR TYPE

PLAN LEGEND

KEYNOTE TAGXX

DOOR TAG

MATCH LINE

2.0

WALL TYPE TAG

XXX

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:5

P

M

A 4 04 8 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

ENLARGED NEW FLOOR PLAN - PART 'B'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1/8" = 1'-0"

NEW - SECOND LEVEL FLOOR PLAN - PART 'B'

N

2nd FLOOR KEY PLAN

N

NEW KEYNOTES

Key Value Keynote Text

NF2 PATCH END OF WALL MATCH (E) ADJACENT FINISH

NF4 INFILL (E) OPENING WHERE DOOR WAS REMOVED. MATCH

(E) ADJACENT WALL ASSEMBLY; ASSUMED WALL TYPE 3.

NF6 PATCH/REPAIR EXISTING FLOORING AND CEILING TO

MATCH (E) FINISH WHERE WALL IS REMOVED. USE

SALVAGED CARPET FROM DEMO.

AREA OF

WORK ~ PART

'A'

SECOND LEVEL

114' - 6"

<E> WALL BUMP OUT TO REMAIN

18" DEEP PLASTIC

LAMINATE MICROWAVE

SHELVES TO MATCH

CABINETRY ON HIDDEN

COUNTERTOP BRACKETS

PLASTIC LAMINATE COUNTERTOP

W/ 4" INTEGRAL BACKSPLASH

36" CLEAR MIN.

WC24

2' - 0"

WC24

2' - 0"

WC36

3' - 0"

WC36

3' - 0"

WC18

1' - 6" 4' - 6"

PROVIDE 4" TOE KICK

W/ RUBBER BASE

REF.

BC24

2' - 0"

DW

2' - 0"

SB36 (ADA)

3' - 0"

BC36

3' - 0"

BC36

3' - 0"

BC36

3' - 0"

FILLER V.I.F.

5 1/8"

A5 01

A5 01

A5 01

A5 01

A5 01

A5 01

C L E

A R

(N) SINK,

RE: PLUMB

XX-XXX

= CASEWORK TYPE TAG

BC = BASE CABINET

SB = SINK BASE

TC = TALL CABINET

WC = WALL CABINET

DR = DRAWER

DO = DOOR

RF = REFRIGERATOR

DW = DISH WASHER

CASEWORK TYPE CASEWORK INDICATOR

= KEYED NOTE

GENERAL LEGEND:

GENERAL CASEWORK NOTES

1. PROVIDE PLAM FINISHED END PANELS AT ALL EXPOSED CABINET SURFACES

2. REFRIGERATOR, DW AND MICROWAVES PROVIDED BY NRCS. INSTALLED BY

CONTRACTOR

SECOND LEVEL

114' - 6"

HIDDEN COUNTER

BRACKETS, TYP AT EACH

STUD LOCATION AND

WITHIN 3" OF

COUNTERTOP ENDS

PLAM COUNTER

1/4" RADIUS EDGE

1' - 6"

A D

J A

C E

N T

C A

B 'S

M

A T

C H

H E

IG

H

T O

F

PLAM FLAT PANEL DOOR

RUBBER

BASE

BLOCKING

MELAMINE INTERIOR

FINISH (WHITE)

WIRE DOOR PULL

CABINET DOOR

1/4" RADIUS EDGE

/2

SINK, RE:

MECHANICAL

/2

4"

8"

KNEE SPACE OUTLINE11"

BLOCKING

INTEGRAL TOE KICK.

ATTACH TO DOOR WITH

CONT. METAL ANGLES.

PIPE SHIELDING

INSULATION ON ALL

PLUMBING LINES

BELOW SINK

WOOD FALSE DRAWER

PANEL

/2

M A

X

PLAM COUNTERTOP

/2

PLAM COUNTERTOP

W/ 4" INTEGRAL

BACKSPLASH

BLOCKING BY G.C.

CABINET BACK

BLOCKING BY G.C.

FINISHED FLOOR

LINE

DISHWASHER,

RE: SPEC

/2

/2

7/8"

2'-1 1/2" U.N.O.

PLAM COUNTERTOP

W/ 4" INTEGRAL

BACKSPLASH

CLOSURE PIECE AS

NECESSARY FOR

DISHWASHER

RUBBER BASE

PLAM FLAT PANEL

LOCKABLE DOOR

LOCKABLE DRAWER

PLAM COUNTERTOP

& BACKSPLASH W/

4" INTEGRAL

BACKSPLASH

2X BLOCKING

BLOCKING

BLOCKING

CABINET BACK

"4"

WIRE DRAWER

PULL.

ADJUSTABLE

MELAMINE SHELF

2'-1 1/2" U.N.O.

PREMANUFACTURED

PLAM BASE CABINET

WITH MELAMINE

INTERIOR

/4

/4

LOCK

RUBBER BASE

LOCKABLE DRAWER

PLAM COUNTERTOP

& BACKSPLASH

2X BLOCKING

BLOCKING

BLOCKING

CABINET BACK

WIRE DRAWER

PULL.

2'-1 1/2" U.N.O.

4"

LOCKABLE

DRAWER

LOCKABLE DRAWER

PREMANUFACTURED PLAM

BASE CABINET WITH

MELAMINE INTERIOR

4" INTEGRAL PLAM

BACKSPLASH

LOCK

WIRE DOOR PULL

(2) ADJUSTABLE SHELVES:

MELAMINE ON 3/4" SUBSTRATE

MELAMINE CABINET

BACK

LOCKABLE PLAM FLAT

PANEL CABINET DOOR

BLOCKING IN WALL

CABINET BLOCKING

1' - 0"

NOTE: MILLWORK PER CURRENT

EDITION OF AWI STANDARDS

CUSTOM GRADE

3/4" PLYWOOD PLAM

SHELF TO MATCH

CABINETRY

PLAM COUNTERTOP

4" INTEGRAL PLAM

BACKSPLASH

C L E

A R

HIDDEN COUNTER

BRACKET, TYP AT EACH

STUD AND W/ IN 3" OF

COUNTERTOP ENDS

1' - 6"

CHAMFER CORNER 6"

TO MEET WALL

CABINET

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:5

P

M

A 5 01 9 50

DAM / RS

DAM / LB 04/15/2019

22X34

CASEWORK DETAILS

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

2nd FLOOR KEY PLAN

N

1/2" = 1'-0"

Break Room 2405 Elevation- South

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1 1/2" = 1'-0"

SECTION @ PHONE BOOTH COUNTER

1 1/2" = 1'-0"

ADA SINK

1 1/2" = 1'-0"

BASE CABINET @ DISHWASHER

1 1/2" = 1'-0"

BASE CABINET W/ DRAWER

1 1/2" = 1'-0"

BASE CABINET - 3 DRAWERS

1 1/2" = 1'-0"

UPPER CABINET

1 1/2" = 1'-0"

WALL SHELVES

3' - 0"

DOOR: RE

SCHEDULE

2"3' - 0"2"1' - 0"2"

4' - 6"

2" 3' - 0" 2"

3' - 4"

DOOR, RE:

SCHEDULE

= DOOR APPROACH DIRECTION

24" MIN

M

IN

*48" MIN (1220) IF

CLOSER IS PROVIDED

(G) LATCH APPROACH,

PUSH SIDE

24" MIN

*54" MIN (1370) IF

CLOSER IS PROVIDED

(F) LATCH APPROACH,

PULL SIDE

M

IN

22" MIN

*IF BOTH CLOSER & LATCH

ARE PROVIDED

**48" MIN (1220) IF BOTH

CLOSER & LATCH

PROVIDED

(E) HINGE APPROACH,

PUSH SIDE

M

IN

12" MIN*

X

(C&D) HINGE APPROACH,

PULL SIDE

Y

22" MIN

(B) FRONT APPROACH,

PUSH SIDE

M

IN

12" MIN*

*IF BOTH CLOSER &

LATCH ARE PROVIDED

18" MIN

(A) HINGE APPROACH,

PULL SIDE

M

IN

X = 36" (915) MIN IF Y = 60"

(1525); X = 42" (1065) MIN

IF Y = 54" (1370)

WALL: SEE WALL TYPES

STEEL STUD

H.M. FRAME

PANEL AS

SCHEDULED

SECOND LAYER OF 5/8"

TYPE 'X' GWB EACH

SIDE TO ACHIEVE

REQUIRED RATING

WALL: SEE WALL TYPES

HEADER --

LIGHT GAGE

STEEL

H.M. FRAME

PANEL, AS

SCHEDULED

NEW OR EXISTING

SECOND LAYER OF 5/8"

TYPE 'X' GWB EACH

SIDE TO ACHIEVE

REQUIRED RATING

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:5

P

M

A 6 01 10 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

DOOR AND WINDOW SCHEDULES

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

DOOR SCHEDULE

NUMBER

ROOM

NUMBER

NEW

DOOR

SALVAGE /

RELOCATE

SALVAGED

DOOR #

DOOR

TYPE

FRAME

MATERIAL

FRAME

TYPE

LEAF

MATERIAL

SIZE FIRE

RATING

HARDWARE

SET COMMENTSTHICKNESS WIDTH HEIGHT

2403A 2403 Yes 1148 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2403B 2403 Yes No A Hollow Metal Steel 1 3/4" 3' - 0" 7' - 0" 1.5 hr 1 CLOSER- adjust door opener so door shall open with a force not to exceed 5 ft lbs

2405 2405 Yes No A Hollow Metal Steel 1 3/4" 3' - 0" 7' - 0" 1.5 hr 1 CLOSER- adjust door opener so door shall open with a force not to exceed 5 ft lbs

2406 2406 Yes No A Hollow Metal Steel 1 3/4" 3' - 0" 7' - 0" 1.5 hr 1 CLOSER- adjust door opener so door shall open with a force not to exceed 5 ft lbs

2408 2408 Yes 1140 EXIST. Hollow Metal (E) 1 3/4" 3' - 0" 7' - 0" 3

2409 2409 Yes No A Hollow Metal Solid Core Wood 1 3/4" 3' - 0" 7' - 0" 3

2411 2411 Yes 1139 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2413 2413 Yes 1151 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2414 2414 Yes 1141 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 2

2415 2415 Yes 1150 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2416 2416 Yes 1149 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 2

2418 2418 No Yes 1128 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2419 2419 Yes 2410 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2424 2424 Yes 1198 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2425 2425 Yes 1197 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 2

2426 2426 Yes 2419 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 4

2427 2427 Yes 2418 EXIST. Hollow Metal B (E) 1 3/4" 3' - 0" 7' - 0" 2

1/2" = 1'-0"

DOOR LEAF TYPE A

1/2" = 1'-0"

DOOR FRAME TYPE B

1/2" = 1'-0"

DOOR FRAME TYPE A 1/4" = 1'-0"

DOOR CLEARANCES

3" = 1'-0"

TYP. PARTITION DOOR JAMB

3" = 1'-0"

TYP. PARTITION DOOR HEAD

MARK DATE DESCRIPTION

NOTE: CONTRACTOR TO VERIFY DIMENSIONS OF EXISTING DOORS TO BE REUSED. PROMPTLY NOTIFY GOVERNMENT & ARCHITECT IF DIMENSIONS VARY FROM SHOWN ABOVE.

A

A

A

A

A

F .D

W

CPT = CARPET TILE

SL = SHEET LINOLEUM

<E> = EXISTING

RB = RUBBER BASE - ALL WALLS

ACT = ACOUSTIC CEILING TILE

PT = PAINT

- EGGSHELL COLOR SELECTED BY OWNER

- 20% OF ALL WALLS ARE ACCENT.

FINISH SCHEDULE LEGEND

GENERAL FINISH PLAN NOTES

1. REMOVE (E) FINISHES IN ALL LOCATIONS NOTED TO RECIEVE NEW FINISH.

2. IF HAZARDOUS MATERIALS ARE DISCOVERED DURING DEMOLITION, STOP WORK

AND NOTIFY GOVERNMENT.

3. ALLOW FOR TWO ACCENT PAINT COLORS (APPOX. 20% OF WALLS). COLOR TO BE

SELECTED BY OWNER.

4. PROVIDE STAINLESS STEEL ABA TRANSITION STRIPS AT ALL ADJACENT

DISSIMILAR FLOORING.

5. PROVIDE CORNER GUARDS AT ALL OUTSIDE CORNERS OF GYP BOARD WALLS.

6. PATCH AND REPAIR ALL FINISHES DAMAGED BY DEMOLITION OR INSTALLATION

OF EQUIPMENT. MATCH (E) ADJACENT FINISH.

7. PROVIDE SMOOTH AND FLUSH TRANSITION BETWEEN (N) AND (E) GWB.

18.1

C

D

E

F

G

H

I

J

13 14 15 16 17 1816.112.1

STORAGE & IT

WAITING /

RECEPTION

MEETING ROOM 1

MEETING ROOM 2

BREAK ROOM

CLOSET /

STORAGE

N.I.C.

DN

EXISTING MEN'S

RR (N.I.C.)

N.I.C.

EXISTING

WOMEN'S RR

(N.I.C.)

N.I.C.

EXISTING OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. HALL (N.I.C.)

N.I.C.

EXT. COMM /

ELEC. RM. (N.I.C.)

N.I.C.

STATE CONSERV.

OFFICE

SNOW OFFICE

PROGRAMS

OFFICE

JEFFCO STG

PHONE BOOTH

PHONE BOOTH

COPY/ FILE/

STORAGE

ECS OFFICE

ENG. OFFICE

ECS &

ENGINEERING

STORAGE

PLOTTER/ COPY

OPEN OFFICE

OPEN OFFICE

MECHANICAL

SOILS OFFICE

MGT & STRAT.

OFFICE

OPEN OFFICE

CLOSET

PHONE BOOTH

PHONE BOOTH

NF6

NF6NF6

NF2

NF4 NF4

LEGEND:

CARPET

SHEET LINOLEUM

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:5

P

M

A 6 02 11 50

DCA / RS

DAM / LB 10/06/2017

22X34

2ND FLOOR

ROOM FINISH SCHEDULE AND DETAILS

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

ROOM FINISH SCHEDULE

ROOM

NUMBER Area NAME

FLOOR

FINISH BASE

CEILING

FINISH

WALL

FINISH COMMENTS

2401 327 SF WAITING / RECEPTION CPT RB ACT PT

2402 79 SF COPY/ FILE/ STORAGE CPT RB ACT PT

2403 483 SF MEETING ROOM 1 CPT RB ACT PT

2405 321 SF MEETING ROOM 2 CPT RB ACT PT

2406 332 SF BREAK ROOM SL RB <E> ACT PT

2408 80 SF JEFFCO STG SL RB OPEN PT

2409 389 SF STORAGE & IT SL RB OPEN PT

2411 127 SF STATE CONSERV. OFFICE CPT RB ACT PT

2412 2891 SF OPEN OFFICE CPT RB ACT PT

2413 113 SF PROGRAMS OFFICE CPT RB ACT PT

2414 34 SF PHONE BOOTH CPT RB ACT PT

2415 113 SF SNOW OFFICE CPT RB ACT PT

2416 34 SF PHONE BOOTH CPT RB ACT PT

2417 18 SF CLOSET <E> <E> <E> ACT PT

2418 113 SF MGT & STRAT. OFFICE CPT RB ACT PT

2419 113 SF SOILS OFFICE CPT RB ACT PT

2420 291 SF MECHANICAL <E> <E> <E> PT

2421 1514 SF OPEN OFFICE CPT RB ACT PT

2422 106 SF PLOTTER/ COPY CPT RB ACT PT

2423 250 SF ECS & ENGINEERING STORAGE CPT RB ACT PT

2424 114 SF ENG. OFFICE CPT RB ACT PT

2425 30 SF PHONE BOOTH CPT RB ACT PT

2426 114 SF ECS OFFICE CPT RB ACT PT

2427 30 SF PHONE BOOTH CPT RB ACT PT

2428 824 SF OPEN OFFICE CPT RB ACT PT

1/16" = 1'-0"

NEW - SECOND LEVEL FINISH PLAN - OVERALL

MARK DATE DESCRIPTION

NEW KEYNOTES

Key Value Keynote Text

NF2 PATCH END OF WALL MATCH (E) ADJACENT FINISH

NF4 INFILL (E) OPENING WHERE DOOR WAS REMOVED. MATCH

(E) ADJACENT WALL ASSEMBLY; ASSUMED WALL TYPE 3.

NF6 PATCH/REPAIR EXISTING FLOORING AND CEILING TO

MATCH (E) FINISH WHERE WALL IS REMOVED. USE

SALVAGED CARPET FROM DEMO.

P

= SHADED AREA

INDICATED AREA OF

CEILING DEMOLITION

= 2x4 LIGHT FIXTURE TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

= MECHANICAL 2X2 RETURN AIR

FIXTURE TO BE REMOVED OR

RELOCATED, RE: MECHANICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

= CEILING MOUNTED EXIT SIGN WITH

ALUMINATED DIRECTIONAL ARROWS TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

= 2x2 - ACOUSTIC

CEILING TILE (ACT) &

TRACK

TO REMAIN

= 2x4 - ACOUSTIC CEILING TILE

(ACT) SCORED TO LOOK LIKE

2X2 & TRACK TO BE REMOVED

= SEMI RESSED FIRE SPRINKLER (DOWN) TO BE

REMOVED OR RELOCATED,

RE: FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= CEILING MOUNTED FIRE STROBE AND

SPEAKER TO BE REMOVED OR RELOCATED, RE:

FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= CEILING MOUNTED SMOKE DETECTOR TO BE

REMOVED OR RELOCATED,

RE: FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= RESSED CANLIGHT FIXTURE TO BE REMOVED

OR RELOCATED

RE: ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION

= GYPSUM BOARD

CEILING TO REMAIN

CEILING LEGEND:

= MECHANICAL 2x2 AIR SUPPLY

FIXTURE TO BE REMOVED OR

RELOCATED, RE: MECHANICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

= WALL MOUNTED EMERGENCY SIGN WITH

LUMINATED DIRECTIONAL ARROWS TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

G

H

I

J

13 14 15 16 17 1816.112.1

DC1

DC1

DC2

DC3

DC1

DC2

MATCH LINE

AREA OF

WORK ~ PART

'A'

EXECUTIVE

LARGE MEETING

ROOM

STATE

CONSERVATIONIST

DEPUTY

STATE

CONSERVATIONIST

RECEPTION AREA

2405A

HALL WAY

2405B

COMM/ ELEC.

N.I.C.

MEN'S TOILET

NO. 3

N.I.C.

WOMEN'S TOILET

NO. 3

N.I.C.

MAIL ROOM

OFFICE PAS

OFFICE

OPERATIONS

OFFICE

PROGRAMS

OFFICE ECS

OFFICE AREA

OFFICE ADMIN.

OFFICE ADMIN.

OFFICE ADMIN.

N.I.C.

OFFICE ADMIN.

N.I.C.

HALL WAY

N.I.C.

GENERAL DEMO CEILING NOTES

1. REFER TO MECH., ELEC., FIRE PROTECTION SHEETS FOR DEMO OR

RELOCATION OF FIXTURES.

2. <E> ANGLED GYP. SOFFIT TO REMAIN.

3. PATCH AND REPAIR ALL CEILING SURFACES THROUGHOUT AREA OF WORK

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:0

P

M

A 7 01 12 50

DCA / RS

DAM / LB 04/152019

22X34

2ND FLOOR

ENLARGED DEMO REFLECTED CEILING PLAN - PART 'A'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1/8" = 1'-0"

DEMO - SECOND LEVEL RCP - PART 'A'

N

2nd FLOOR KEY PLAN

N

DEMO RCP KEYNOTES

Key Value Keynote Text

DC1 (E) ANGLED GYP. SOFFIT TO REMAIN

DC2 (E) SOFFIT TO REMAIN

DC3 REMOVE PORTION OF (E) MASONRY WALL, (E) BEAM TO

REMAIN

MATCH LINE

= SHADED AREA

INDICATED AREA OF

CEILING DEMOLITION

= 2x4 LIGHT FIXTURE TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

= MECHANICAL 2X2 RETURN AIR

FIXTURE TO BE REMOVED OR

RELOCATED, RE: MECHANICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

= CEILING MOUNTED EXIT SIGN WITH

ALUMINATED DIRECTIONAL ARROWS TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

= 2x2 - ACOUSTIC

CEILING TILE (ACT) &

TRACK

TO REMAIN

= 2x4 - ACOUSTIC CEILING TILE

(ACT) SCORED TO LOOK LIKE

2X2 & TRACK TO BE REMOVED

= SEMI RESSED FIRE SPRINKLER (DOWN) TO BE

REMOVED OR RELOCATED,

RE: FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= CEILING MOUNTED FIRE STROBE AND

SPEAKER TO BE REMOVED OR RELOCATED, RE:

FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= CEILING MOUNTED SMOKE DETECTOR TO BE

REMOVED OR RELOCATED,

RE: FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION

= RESSED CANLIGHT FIXTURE TO BE REMOVED

OR RELOCATED

RE: ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION

= GYPSUM BOARD

CEILING TO REMAIN

CEILING LEGEND:

= MECHANICAL 2x2 AIR SUPPLY

FIXTURE TO BE REMOVED OR

RELOCATED, RE: MECHANICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

= WALL MOUNTED EMERGENCY SIGN WITH

LUMINATED DIRECTIONAL ARROWS TO BE

REMOVED OR RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

C

D

E

F

G

15 16 16.1

DC1

DC1

DC1

DC1

DC1

MATCH LINE

AREA OF

WORK ~ PART

'B'

FILE/STORAGE

ROOM

PROGRAMS

2410CLOSET

OFFICE AREA

ECS PLOT AREA

& SUPPORT

SPACE

OFFICE AREA

EXISTING MECH.

EQUIP/FURN

STORAGE PAS

FILE STORAGE

LIBRARY

STAIR

N.I.C.

GENERAL DEMO CEILING NOTES

1. REFER TO MECH., ELEC., FIRE PROTECTION SHEETS FOR DEMO OR

RELOCATION OF FIXTURES.

2. <E> ANGLED GYP. SOFFIT TO REMAIN.

3. PATCH AND REPAIR ALL CEILING SURFACES THROUGHOUT AREA OF WORK

715 FOURTEENTH STREET

GOLDEN, COLORADO 80401

(303) 278-4378

FAX (303) 278-0521

Principal: Dave Anderson

AIA, LEED AP

daveanderson@andarch.com

D R

A W

IN

G

DRAWING NO.

CHECKED BY

DRAWN BY

FLOOR NO.

FILE NAME

DRAWING TITLE

SUB. DATE

SUBMISSION

GSA PM

PROJECT NO.

PROJECT

DESCRIPTION

PROJECT

TITLE

FACILITY CODE

OTHER

BUILDING NOs

BUILDING NO.

CITY/ST./ZIP

STREET

NAME

CONSTR. CON.

SUB A/E

PRIM A/E

CONS. WORK

CONS. CONTR.

A/E TASK NO.

A/E CON. NO.

P R

O

JE

C T

B U

IL

D

IN

G

C O

N T

R A

C T

O R

S G

R

AP

H

IC

S C

AL

E

R E

V

IS

IO

N

N O

T E

S K

E Y

P

LA

N C

E R

T

IF

IC

A

T

IO

N S

Ben Reko

Project Manager

D.F.C. BUILDING 41 ~ SUITE 246

DENVER, COLORADO ~ 80255

303.236.0855 Phone | 720.412.2812 Cell

benjamin.reko@gsa.gov

GENERAL SERVICES

ADMINISTRATION

SHEET OF

DISCIPLINE SHEET TYPE SEQUENCE

SHEET SIZE:

DATE DRAFTED:

ANDERSON HALLAS

ARCHITECTS, PC

PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.8 /8

/2

:0

:0

P

M

A 7 02 13 50

DCA / RS

DAM / LB 04/15/2019

22X34

2ND FLOOR

ENLARGED DEMO REFLECTED CEILING PLANS - PART 'B'

07/25/2019

100 CD ISSUE

BEN REKO

EP-GS-P-08-16-JB-7053

BUILDING 56 - 2ND FLOOR NRCS

CONSOLIDATION

BUILDING 56 - NRCS

BUILDING 56

DENVER, COLORADO 80255

6TH STEET

BUILDING 56

ANDERSON HALLAS ARCHITECTS PC

GS-08P-13-JB-D-0032

EP-GS-P-08-16-JB-7053

GS-08P-JB-D-0017

100% CONSTRUCTION DOCUMENTS

BUILDING 56 - 2ND FLOOR

NRCS CONSOLIDATION

-- FOR CONSTRUCTION --

1/8" = 1'-0"

DEMO - SECOND LEVEL RCP - PART 'B'

N

2nd FLOOR KEY PLAN

N

DEMO RCP KEYNOTES

Key Value Keynote Text

DC1 (E) ANGLED GYP. SOFFIT TO REMAIN

DC2 (E) SOFFIT TO REMAIN

DC3 REMOVE PORTION OF (E) MASONRY WALL, (E) BEAM TO

REMAIN

G

H

I

J

13 14 15 16 17 1816.112.1

NC1

A7 03

NC5

NC4

NC7

NC7

NC7

NC7

AREA OF

WORK ~ PART

'A'

STORAGE & IT

WAITING /

RECEPTION

MEETING ROOM 1

BREAK ROOM

CLOSET /

STORAGE

N.I.C.

EXISTING MEN'S

RR (N.I.C.)

N.I.C.

EXISTING

WOMEN'S RR

(N.I.C.)

N.I.C.

EXISTING OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. OFFICE

(N.I.C.)

N.I.C.

EXT. HALL (N.I.C.)

N.I.C.

EXT. COMM /

ELEC. RM. (N.I.C.)

N.I.C.

STATE CONSERV.

OFFICE

JEFFCO STG

MEETING ROOM 2

COPY/ FILE/

STORAGE

OPEN OFFICE

PROGRAMS

OFFICE

SNOW OFFICE

PHONE BOOTH

PHONE BOOTH

GENERAL CEILING NOTES

1. REFER TO MECH., ELEC., FIRE PROTECTION SHEETS FOR

CEILING FIXTURE LOCATIONS AND ADDITIONAL

INFORMATION

2. REINSTALL <E> WINDOW COVERINGS IN SAME LOCATION.

PROTECT IN PLACE. TYP. ALL WINDOWS

= 2x4 LIGHT FIXTURE NEW OR

RELOCATED, RE:

ELECTRICAL DRAWINGS

FOR ADDITIONAL INFORMATION

= MECHANICAL 2X2 RETURN AIR

FIXTURE NEW OR RELOCATED, RE:

MECHANICAL DRAWINGS FOR

ADDITIONAL…