This is a bid pack document for razor ribbon enhancements at the Earnest C. Brooks Correctional Facility in Muskegon, Michigan, managed by Matrix Consulting Engineers, Inc. The project (Index #37180, File #472/17405.SMD, Matrix Project #17297.00) involves security fence enhancements at 2500 South Sheridan Road, Muskegon, MI 49444. The technical drawings show detailed plans for installing new detainer hook razor ribbon with 12" loop spacing along existing interior and exterior security fences, including multiple fence sections ranging from 28" to 40" in height.

The site plan drawings illustrate the facility's layout and proposed fence modifications, with specific installation details for different fence sections and attachment methods. The project includes multiple fence types (labeled as "A" and "B" fences) and includes specifications for approach paths and existing infrastructure integration. The drawings provide comprehensive technical details for contractors, including exterior fence details, wall fence details, and specific mounting requirements for the razor ribbon security enhancements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-000

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

37180 consultant job no.

17297.00 sheet title

472/17405.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

50% REVIEW SET 03/19/2018

BID PACK #3A 04/13/2018

C-100

JKB

JFS

N file no.

checked by drawn by consultant issue date index no.

contract order no.

37180 consultant job no.

17297.00 sheet title

472/17405.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FENCING AND GATES NOTES

1. ALL FABRIC, RAILS, POSTS, GATES AND FITTINGS SHALL BE HOT-DIPPED GALVANIZED

STEEL WITH ZINC COATING, UNLESS NOTED OTHERWISE. ALL FABRIC SHALL BE 2"

DIAMOND MESH.

2. ALL CHAIN LINK FENCE, GATE AND COMPONENTS SHALL HAVE GALVANIZED FINISH.

3. ALL FENCING TO BE KNUCKLED TOP AND BOTTOM.

4. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL FENCING.

5. ALL FRAMES SHALL BE CONSTRUCTED IN SHOP. CONTRACTOR SHALL FIELD-MEASURE

POSTS PRIOR TO CONSTRUCTION.

6. ALL GATE FRAMES SHALL BE CONSTRUCTED WITH WELD CUPPED JOINTS (FISH MOUTH).

7. ALL WELDS SHALL BE CLEAN, UNIFORM, CONTINUOUS AND FREE OF RUST. GRIND

WELDS SMOOTH AND CLEAN PRIOR TO APPLICATION OF GALVANIZED FINISH.

GRADE

EXISTING INTERIOR

"A" FENCE

EXISTING EXTERIOR

"B" FENCE

EXISTING SPOOLS,

TYP

16'-0" x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

EXISTING SPOOLS,

TYP

x x x x x x x x x x x x x x x x x x x x x x x x x x

11'-6" x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING 36

x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

ADD DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

ADD INSTABARRIER

RAZOR RIBBON w/ 12"

LOOP SPACING

APPROACH

6'-4"

GATOR

x x x x x x x x x x x x xGRADE

EXISTING

INTERIOR

FENCE

x x x x x x x x x x x x x x x x x x x x x x x x x x

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x

GRADE

EXISTING

INTERIOR

FENCE

x x x x x x x x x x x x x x x x x x x x x x x x x x

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x

GRADE

EXISTING

INTERIOR

FENCE

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x

DETAINER HOOK

RAZOR RIBBON w/ 12"

LOOP SPACING

x x x x x x x x x x x x x x x x x x x x x x x x x x

NEW 31" DETAINER

HOOK RAZOR RIBBON

@ 12" OC

x x x x x x x x x x x

EXISTING BUILDING

x x x x x x x x x x x x x

EXISTING SPOOLS

x

C-200

JKB

JFS

file no.

checked by drawn by consultant issue date index no.

contract order no.

37180 consultant job no.

17297.00 sheet title

472/17405.SMD

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

R O

B

ER

T C

. H A

LL

, R

A , N

C A

R B

, D

IR

EC

TO

R

ST

A

TE

F

A C

IL

IT

IE

S

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

File details come from the government source that posted it. Updated .