2018-05-407 Polvadera Fire Station Bid Set Drawings.pdf
PDF 13 MB Posted
- Attached to
- Polvadera Fire Station
- Solicitation number
- 2018-05-407
- Issued by
- Socorro County, New Mexico
About this file
The 2018-05-407 Polvadera Fire Station Bid Set Drawings represent a comprehensive construction project for the Midway Fire District in Socorro County, New Mexico. The project involves constructing a new 5,000 square foot fire station facility located on I-25 Frontage Road, designed by Studio Southwest Architects with a bid set dated February 8, 2018. The architectural plans detail a pre-engineered metal building structure with multiple service bays, administrative spaces, restrooms, and support areas, spanning approximately 50' x 100' with a 16' height. The project encompasses complete architectural, structural, mechanical, electrical, and plumbing designs, including site grading, utility connections, concrete foundations, metal building erection, interior finishes, and associated infrastructure.
The project documents indicate a type V-B non-sprinkled construction with mixed-use occupancy (B and S1), involving extensive site work including earthwork, site utilities, paving, and concrete foundations. The bid set includes detailed technical specifications for structural elements, mechanical systems, electrical installations, and site development, with provisions for specialized components like a septic system, water connections, and LP gas infrastructure. While specific budget details are not explicitly outlined in the drawings, the comprehensive nature of the documentation suggests a complex, purpose-built facility requiring specialized construction expertise. The project appears to be funded by Socorro County, with specific considerations for local and veteran contractor preferences, and compliance with New Mexico state procurement regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2018-05-407 Addendum #1.pdf | ||
| 2018-05-407 Polvadera Fire Station Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
��/0�'� �'�&/��&12�1��*3��'�&/��&12/� �"-�� !"��444&5!)+ (54*���&�(6 �6* ,��6* ,75!)+ (54*���&�(6
�������'��%��!)+ (��()!�4"5!����� !"�!5%��#�& �)8, �*! (#�(���"8�(+)�! (#�-9�*#9�6"*#5�4 !�()!�!�"�"38�"55�4� !!"# �(#5"#!�(:��!)+ (��()!�4"5!����� !"�!5%��#�&� 5�*�; (,*! (#�(:�:"+"�*, *#+��#!"�#*! (#*,�,*4&���"� #:(�6*! (#��(#!* #"+� #�!� 5�+(�)6"#!� 5�!�"� #!",,"�!)*,�8�(8"�!9�(:��!)+ (��()!�4"5!%��#�&�*#+�*,,�� $�!5�!�"�"!(�*�" �"5"�;"+&��(��"3�"8! (#5��":"��!(�!�"��4#"�<���� !"�!��$�""6"#!&
�5
=5
!5
���A����������
��B�������
�����C�
�0'�
�A��������%
''''B<''�&�A�
��10�'� ���D�'�E�/��<12�1 ��C��������D�'�E�/��<12/�
7����������
�����C���@���'����� ��/0'/� ���D�'�E�/��<'�/1
��C��������D�'�E�CCC<''''
���������������7
B� B ������A�� ��/0��' ���D�'�E����<0/'� ��C��������D�'�E����<01'�
���B���B��B� �F ��B��B� �F7��?� B&
��A�F<B���A�� �0''��� ��/0�'1 ���D�'�E����<�'/'
�����������D�'�E���1<0�0�
���B���B��������� �������B�������7 B<� B��&
B� B ������A�� ��/0��' ���D�'�E����<0/'� ��C��������D�'�E����<01'�
���B���B��B� �F ��B��B� �F7��?� B&
B� B ������A�� ��/0��' ���D�'�E����<0/'� ��C��������D�'�E����<01'�
���B���B��B� �F ��B��B� �F7��?� B&
B� B ������A�� ��/0��' ���D�'�E����<0/'� ��C��������D�'�E����<01'�
���B���B��B� �F ��B��B� �F7��?� B&
���A������ �����C�
| � | ����� | ���� |
| � | � |
��������/�G��<��� ��B������
B�� ��C
<�'� �����B���� B�� �B�����
�����B������
���������B�������
B���
B<''� �A��������%���� �
B<''� ���������������
�<��A�����
�������A��������� B����������
�������A��������� B�
�"; 5 (#����"+),"
( �*!" �"5�� 8! (#
�<''����������������������A����� ����B� �<''�����������������B� �<2'������������������
������A%��������%� ��C�G B�
�<��A�����
B����
�<��A�����
�<�'� �C������������� B����A����
���B������ B����B���
�<2'� ������ ������%������G������������%���B
B����������� B�����A�������������������� B� ����%��'�0
B���� B��������� ���G������� B��?�����
���G������� B���B� ��B�
�<''� ����������B� �������A����� �<''� B� �<�'� ��B��� B���� �<2'� ���B�������������
Digitally signed by Ron Burstein
DN: cn=Ron Burstein, o=Studio
Southwest Architects Inc., ou, email=rburstein@studioswarch.
com, c=US
Date: 2018.02.07 11:37:47 -07'00'
�0
�1�
���2�
�34-*+54+ �67*6553
"�86+,*6 �9� �:;8<853<85% /0��� � �/���1��1 � �/���1�/� �5;
�*+5' ===�>+89*�>=,34-�4�?
?,*:@>+89*�>=,34-�4�?
�+89*� ��8+-=5>+ �34-*+54+>% �64� �8A:*4,+*�6 �3 35A3�984+*�6 ;B ,6B ?5,6> =*+-�8+ +-5 5)A35>> =3*++56 4�6>56+ �C �+89*� ��8+-=5>+ �34-*+54+>% �64� D*�:,+*�6 �C C5953,:
,69 �6+536,+*�6,:
�-5 *6C�3?,+*�6 4�6+,*659 *6 9�48?56+ +-5
*6+5::54+8,:
A3�A53+B �C �+89*� ��8+-=5>+% �64� ,69 3*7-+> +-535+� ,35 �5>53D59� ��3 5)45A+*�6> 35C53 +-5 �=653&�34-*+54+ �7355?56+�
'E
3> E> E� E�
*9 B
*3
F
+3 :F �3 D
G� G�
�0��
�:,6 ��3+- �385 ��3+-
�G/� H
�5D*>*�6 �4-598:5
�� �,+5 �5>43*A+*�6
| �������� | � |
| �� |
#,>*4 �::�=,;:5 �35, 1%��� A53
�+�-$0
�BA5
�448A,64B ?,)*?8?
>+�3*5> ��I ?,)*?8?
-5*7-+�
!�.��!.����/�0�/1
�1����)� ��2� � �� ���2��� J�3 H
��65
�2���0�3�� ���
����3�3����� �1����*"� � �&���4�+$, C�3 9*>+,645 735,+53 +-,6 ��I
���� � �4 �� !���� � �4 ��
3����� ������ ���4$�$0
| $�% | 5� |
| �� |
��5����)���� �6� #8>*65>> �35, ��� >C 3�>>G�44� "54-,6*4,:G�+�3,75 ��� >C 3�>>G�44� �*35 �384K �,3K*67 ,3,75
>C 3�>>G�44�
| � | ����� | � ��*���� | |
| ��7 | � |
����6 !�������������������������"8
������*)���2���
� �1���/�2�(�� �55 �735>> A:,6 C�3 5)*+ =*9+- 4,:48:,+*�6>
Digitally signed by Ron Burstein
DN: cn=Ron Burstein, o=Studio
Southwest Architects Inc., ou, email=rburstein@studioswarch.c om, c=US
Date: 2018.02.07 11:38:30 -07'00'
Digitally signed by Ron Burstein
DN: cn=Ron Burstein, o=Studio
Southwest Architects Inc., ou, email=rburstein@studioswarch.c
Date: 2018.02.07 11:48:40 -07'00'
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
O H
E
O H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
E A
S T
F
R
O
N
T A
G
E
R
O
A D
I
P
A V
E D
DRIVE (UNIMPROVED)
N88°12'20"W
707.46'
N E
S89°37'27"E 1321.82'
GRAVEL
PILE
D R
IV
E
(G R
A V
E L
COUNTY OF SOCORRO
22.742 ACRES
TR 1-D
TR 1-C
TR 1-B
TR 1-A
T H
R
E
P
A
S
E
SINGLE PHASE
COUNTY TRANSFER STATION
6" WL
S S
S S
S
FF=96.98
G A
S
GAS GAS
W
WWWW
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
FF=96.98
2 SPACES
@ 9'x 20'
1 HC SP.
@ 8'x 20'
8'
1 HC SP.
@ 8'x 20'
24'
12'
R
R
G A
S
GAS GAS
E
KEYED NOTES
X
1" = 50'
5025 100
1. CONSTRUCT PAVED ROAD. SEE DETAIL 4/C-501 & 7/S501.
(NOT IN CONTRACT)
2. INSTALL CONCRETE PAVING PER DETAIL 5/C-501 & 6/S501.
3. INSTALL ACCESSIBLE PARKING SPACES. SEE DETAIL
1/C-501.
4. INSTALL ACCESSIBLE PARKING SIGNS PER DETAIL 2/C-501.
5. INSTALL WHEEL STOPS. SEE DETAIL 3/C-501.
6. CONSTRUCT 34 LF 21" x 15" CMP CULVERT AT 2%.
7. CONSTRUCT 45 LF 21" x 15" CMP CULVERT AT 1%.
8. LOCATION OF PROPANE TANK WITH 4" CONCRETE UTILITY
PAD.
9. LOCATION OF SEPTIC SYSTEM.
10. PROPOSED PONDING AREA APPROX. 5000CF OF STORAGE.
FROM ELEVATION 4680 TO 4681.
Scale: 1" = 50'
SITE GRADING AND DRAINAGE PLAN
Architect Engineer
P
M
Revision Schedule
No Date Description
Engineers Planners Construction Services
8102 Menaul Blvd. NE, Suite D
Albuquerque, NM 87110 tele: 505.255.7802 fax: 505.255.7902
Project No.: 17-006 www.abqeng.com
Scale: 1" = 20'
ENLARGED PLAN
SEE ENLARGED PLAN,
THIS SHEET FOR DETAILS
C-101
LEGEND
22.8
FF
EXISTING WATERLINE
EXISTING OVERHEAD ELECTRIC LINE
NEW ASPHALT PAVEMENT (N.I.C)
FINISH FLOOR ELEVATION
DIRECTION OF FLOW
NEW CONCRETE
NEW BUILDING
NEW SANITARY SEWER LINE
SS
WW
OHE
NEW STORM DRAIN
WW NEW WATERLINE
GAS
NEW GAS LINE
TT
EXISTING TELEPHONE LINE
NEW SIGN
NEW SANITARY SEWER CLEANOUTS
EXISTING INDEX CONTOUR
EXISTING INTERIM CONTOUR
NEW SPOT ELEVATION
NEW INDEX CONTOUR
NEW INTERIM CONTOUR
THE SITE IS LOCATED ON COUNTY OF SOCORRO PROPERTY, BEING A PORTION OF TRACT 42A NEAR
CHAMISAL, SOCORRO COUNTY, NM, LOCATED NEAR THE INTERSECTION OF INTERSTATE 25 AND NEW MEXICO
STATE HWY 408. NEW CONSTRUCTION ON THIS PROJECT WILL DISTURB APPROXIMATELY 2.7 ACRES.
WITH THIS DEVELOPMENT, ONE NEW STRUCTURE WILL BE CONSTRUCTED TO PROVIDE A FIRE STATION. THIS
SITE HISTORICALLY DRAINS FROM NORTH TO SOUTH. THE DIFFERENCE BETWEEN PRE-DEVELOPED AND
DEVELOPED RUNOFF FOR THE ENTIRE SITE WILL ME MINIMUM DUE TO THE SMALL 2.7 ACRES BEING
DEVEOLPED COMPARED TO THE ENTIRE 22.7 ACRES SITE. HOWEVER THE DEVELOPED RUNOFF FROM THE
PROPOSED IMPERVIOUS AREAS WILL BE DIRECTED BY SHEET FLOW IN A DIRECTION SIMILAR TO AND A
RATETHAT HONORS THE EXISTING DRAINAGE PATTERNS. THESE PATTERNS FLOW SOUTH FROM THE
PROPOSED BUILDING SITE. THE MAJORITY OF THIS DEVELOPED RUNOFF FROM NEW CONSTRUCTION, BUILDING AND PAVEMENT WILL BE DIRECTED TOWARDS AN EXISTING LOW POINT ON THE SITE, WHICH WILL
BE USED AS A PONDING AREA FOR THE DEVELOPED RUNOFF. THE PROPOSED PONDING AREA IS NEAR THE
SOUTHERN BOUNDARY OF THE SITE. THIS SITE ACCEPTS MINIMUL OFFSITE FLOWS FROM THE PROPERTIES
ALONG ITS WESTERN BOUNDARY, THE MAJORITY OF WHICH IS DIRECTED TOWARDS THE EXISTING PONDING
AREA. THIS SITE IS LOCATED WITHIN MINIMAL FLOOD HAZARD ZONE "X" FLOODPLAIN.
DRAINAGE NARRATIVE
GENERAL NOTES
A. DIGITAL FILE WILL BE PROVIDED TO OWNER AND
SURVEYOR FOR PURPOSES OF LAYOUT FOR THE
PROPOSED SITE ACCESS ROAD, DRIVES AND BUILDING.
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
OHE
O H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
O
H
E
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
E A
S T
F
R
O
N
T A
G
E
R
O
A D
I
P
A V
E D
DRIVE (UNIMPROVED)
707.46'
N E
S89°37'27"E 1321.82'
D R
IV
E
(G R
A V
E L
TR 1-D
TR 1-C
TR 1-B
TR 1-A
T H
R
P
A
S
E
SINGLE PHASE
COUNTY TRANSFER STATION
6" WL
S S
S S
S
T
Y P
63.33'
FF=96.98
G A
S
GAS GAS
W
WWWW
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
25'
E
E E E
E E
E
OHE
OHE
OHE
OHE
1" = 50'
5025 100
Scale: 1" = 50'
SITE UTILITY PLAN
Architect Engineer
P
M
Revision Schedule
No Date Description
Engineers Planners Construction Services
8102 Menaul Blvd. NE, Suite D
Albuquerque, NM 87110 tele: 505.255.7802 fax: 505.255.7902
Project No.: 17-006 www.abqeng.com
X
DESIGN PARAMETERS
KEYED NOTES
1. INSTALL DOUBLE CLEANOUT.
2. CONSTRUCT 18 LF 4" PVC SEWER LINE AT 2.08%. SEE PLUMBING
PLANS FOR CONTINUATION.
3. INSTALL 4" - 45° BEND.
4. INSTALL 2,000 GALLON H-20 SEPTIC TANK, PER REG. 20.7.3.
TANK AND EQUIPMENT TO BE PLACED IN NON-TRAFFIC AREA.
5. CONSTRUCT 149 LF 4" PVC SEWER LINE AT 2.08%.
6. INSTALL 60" x 60" DISTRIBUTION BOX. SEE DETAIL 2, THIS SHEET.
7. CONSTRUCT 3 -1600 BD BIODIFFUSER ARC 36 LEACHING
CHAMBERS AT 63.33' LF EACH WITH TRENCH SYSTEM
INSTALLATION. SEE DETAIL 1, THIS SHEET. INSTALL PER
MANUFACTURER'S SPECIFICATIONS.
8. CONSTRUCT 870' LF OF 1-1/2" WATER LINE.
9. INSTALL NEW 1" WATER METER PER LOCAL WATER AUTHORITY.
"WET TAP" NEW SERVICE INTO EXISTING OFF-SITE WATER LINE.
10. LP GAS REGULATOR AND TANK SIZE BY LP PROVIDER AND
OWNER. SEE LP TANK PAD DETAIL 8/C-501.
11. NEW OVERHEAD LINE, POLE AND TRANSFORMER BY PNM.
12. UNDERGROUND ELECTRICAL FROM TRANSFORMER. INSTALL
SECONDARY FEEDER AND CONDUIT FROM POLE MOUNTED
TRANSFORMER TO BUILDING. SEE E-601 FOR ONE-LINE
DIAGRAM.
SEPTIC TAKE DATA
1. TOTAL DRAINAGE FIXTURE UNITS = 27 NMAS 20.7.3.201.P.(2)
Uniform Plumbing Code
2. SEPTIC TANK SIZE = 2000 GAL. NMAS Table 201.2
ABSORPTION FIELD DESIGN DATA
1. SOIL PERCOLATION RATE = 8 MIN / IN
2. SOIL TYPE = Ib NMAC Table 703.1
3. APPLICATION RATE: AR = 2 sq.ft./gal/day NMAC Table 703.1
4. OFFICE OCCUPANCY: 22 EMPLOYEES @ 20 GPD EACH NMAS Table 201.1
( 11 Max Employees in 2 - 8hr shifts)
5. DESIGN FLOW: Q = 22 X 20 = 440 GPD NMAS Table 201.2
6. REQUIRED ABSORPTION AREA Aa = QxAR = 880 SQ.FT. NMAS 20.7.3.703.H
7. LEACH AREA PER FT OF TRENCH: La = 5 SQ. FT NMAC Product List
8. TOTAL TRENCH LENGTH REQUIRED: Aa / 5 = 176 FT
ABSORPTION FIELD CONSTRUCTION DATA
9. 3 ~ 63.33' LONG TRENCHES (10~MODULAR BIO-DIFUSSERS) = 190' FT.
10. TOTAL ABSORPTION FIELD PROVIDED = La X 190' = 950 SQ. FT. > 880 OK
VICINITY MAP
NOT TO SCALE
N.T.S.
BIODIFFUSER TRENCH DETAIL
N.T.S.
DISTRIBUTION BOX DETAIL
34"
C H
A M
B E
R
H E
I G
H T
BIODIFFUSER
FINISH
GRADE
TRENCH Aa WIDTH=36"
M I N
C
O V
E R
"WALK IN" FILL
PER BIODIFFUSER
MANUFACTURER
OUTLET OUTLET
INLET
OUTLET
OUTLET
OUTLET
OUTLET
60"
48"
60"
48"
36" HOLE
14"14"
PLAN SECTION
NATIVE SOIL
COMPACTED TO 95%
MAXIMUM DENSITY
T R
E N
C H
H E
I G
H T
TRENCH
ABSOPTION AREA
= 1'+1'+3'=5 SF/FT
A a
H E
I G
H T
C-102
Architect Engineer
P
M
Revision Schedule
No Date Description
Engineers Planners Construction Services
8102 Menaul Blvd. NE, Suite D
Albuquerque, NM 87110 tele: 505.255.7802 fax: 505.255.7902
Project No.: 17-006 www.abqeng.com
Scale: NTS
9'
HANDICAP ACCESSIBLE
SIGNAGE WITH "VAN
ACCESSIBLE" SIGNAGE
SEE DETAIL 2, THIS SHEET
12" x 18" SIGN WITH
INTERNATIONAL HANDICAP
SYMBOL AND "HANDICAP
PARKING" MESSAGE
"VAN ACCESSIBLE"
MESSAGE AS REQUIRED
SEE SITE PLAN FOR
LOCATIONS
2" GALVANIZED STEEL
PIPE, PAINTED
3" TYP
8"
8'
HANDICAP ACCESSIBLE
SIGNAGE
SEE DETAIL 2, THIS SHEET
W A
L K
Scale: NTS
Scale: NTS
PAVING SECTION (NOT IN CONTRACT)
ASPHALTIC CONCRETE
SURFACE COURSE
AGGREGATE BASE
COURSE WITH
PRIME COAT
SUBGRADE PREP
COMPACTED TO 95%
DENSITY, MIN.
R-VALUE OF 50 ≥
NOTE: SEE GEOTECHNICAL REPORT
PERFORMED AND COMPLETED BY
WESTERN TECHNOLOGIES INC., DATED
MARCH 24, 2017.
NOTE: PROVIDE TRANSVERSE CONTROL JOINTS AT INTERVALS NOT
EXCEEDING 6'-0" ON CENTER, PROVIDE CENTERLINE CONTROL JOINTS IN
SIDEWALK WIDER THAN 8'-0". SPACING OF CENTERLINE CONTROL JOINTS
SHALL NOT EXCEED 6'-0" OR AS SHOWN ON PLANS. PROVIDE EXPANSION
JOINTS AT INTERVALS NOT EXCEEDING 20'-0" ON CENTER WHERE WALK
DOES NOT ABUT CURB.
Scale: NTS
CONCRETE PAVING DETAIL
BEVEL CORNERS
AS SHOWN
3~#5 CONTINUOUS
HORIZONTALLY
#5 REBAR DOWELED 2'-0" MINIMUM
THRU CONCRETE PAVING
BEVEL
CORNERS
AS SHOWN
6"x 6" PRECAST CONCRETE
WHEEL STOP
M
I N
24"
ASPHALTIC CONCRETE
SURFACE COURSE
1800# STABILITY
AGGREGATE BASE
COURSE WITH
PRIME COAT
6" COMPACTED
SUBGRADE
8" THICK X 24" WIDE
ABC SHOLDER
SUBGRADE PREP
COMPACTED TO 95%
DENSITY, MIN.
R-VALUE OF 50
AGGREGATE BASE
COURSE WITH
PRIME COAT
CONCRETE
SURFACE
Scale: NTS
Scale: NTS
(NOT IN CONTRACT)
C-501
6"
ASPHALTIC CONCRETE
SURFACE COURSE
1800# STABILITY
AGGREGATE BASE
COURSE WITH
PRIME COAT
6" COMPACTED
SUBGRADE
4" THICK CONCRETE
SIDEWALK
Scale: NTS
CONCRETE TO ASPHALT TRANSITION
EXISTING
GRADE
#3 @ 12" O.C.
EACH WAY
SCARIFIED &
RECOMPACTED
SOIL, DOWN TO 18"
BELOW GRADE
45° CHAMFER EDGE (TYP)
PAD SIZE TO ACCOMMODATE
TANK
2-#3 BOTTOM (TYP)
LP GAS TANK BY LP
PROVIDER AND OWNER
Scale: NTS
LP TANK PAD DETAIL
8"
GRADE TO ASPHALT TRANSITION
STRUCTURAL GRAPHIC SYMBOLS
SECTION CROSS-REFERENCE SYMBOL
EXTERIOR ELEVATION CROSS-REFERENCE SYMBOL
INTERIOR ELEVATION CROSS-REFERENCE SYMBOL
PLAN DETAIL CROSS-REFERENCE SYMBOL
DETAIL CROSS-REFERENCE SYMBOL
DRAWING TITLE SYMBOL
GRAPHIC BAR SCALE SYMBOL
NORTH ARROW SYMBOL
KEYNOTE SYMBOL
CONTINUOUS FOOTING MARK SYMBOL
ELEVATION TARGET SYMBOL
STRUCTURAL GRID REFERENCE SYMBOL
REVISION INDICATOR SYMBOL
BASE PLATE MARK SYMBOL
A3
S-311
SECTION NUMBER
SHEET SECTION IS DRAWN ON
B5
S-201
ELEVATION NUMBER
SHEET ELEVATION IS DRAWN ON
C4
S-203
ELEVATION NUMBER
SHEET ELEVATION IS DRAWN ON
C4
S-312
DETAIL NUMBER
SHEET DETAIL IS DRAWN ON
AREA TO
BE DETAILED
C4
S-312
DETAIL NUMBER
SHEET DETAIL IS DRAWN ON
J7
DRAWING TITLE
SCALE: 3/4"=1'-0"
DRAWING TITLE
GRAPHIC BAR SCALE
DRAWING SCALE
DRAWING NUMBER
FIN FLR EL=
100'-0"
DESCRIPTION
ELEVATION
STRUCTURAL GRID INDICATOR
STRUCTURAL GRID LINE
1 2
B
A
REVISION AREA
REVISION NUMBER SYMBOL
1 BASE PLATE MARK
SPOT FOOTING MARK SYMBOL
F1
BP1
SPOT FOOTING MARK
BASE PLATE MARK
CF1 CONTINUOUS FOOTING MARK
WALL MARK SYMBOL
W1 WALL MARK
16'0 4' 8'
16'0 4' 8'
STRUCTURAL MATERIALS LEGEND
STEEL
CAST-IN-PLACE CONCRETE
LIGHTWEIGHT CONCRETE
PRECAST CONCRETE
COMPACTED EARTH
CMU (IN SECTION)
CMU (IN PLAN)
BAR GRATING
CHECKERED PLATE
MASONRY GROUT
GRATING (IN SECTION)
PLYWOOD (IN SECTION)
RIGID INSULATION
GLULAM
COMPACTED EARTH
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABAN ABANDON
ABBRV ABBREVIATION
AC ASPHALTIC CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACP ASPHALTIC CONCRETE PAVING
ACR ACROSS
ACST ACOUSTIC
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADDM ADDENDUM
ADJ ADJACENT/ADJOINING
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHR ANCHOR
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION
ALNMT ALIGNMENT
ALT ALTERNATE, ALTERNATIVE
ALUM ALUMINUM
AMT AMOUNT
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APPX APPENDIX
AR AS REQUIRED
ARCH ARCHITECT
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASPH ASPHALT
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATCH ATTACHMENT
ATTN ATTENTION
AWS AMERICAN WELDING SOCIETY
AZ AZIMUTH
B&F BELL AND FLANGE
BAL BALANCE
B/B BACK TO BACK
BC BOTTOM CHORD
BD BOARD
BDRY BOUNDARY
BEV BEVEL
BFF BELOW FINISH FLOOR
BKG BACKING
BKGD BACKGROUND
BLD BUILD
BLDG BUILDING
BLK BLOCK/BLOCKING
BLT BUILT
BLVD BOULEVARD
BLW BELOW
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
B PL BASE PLATE
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRG PL BEARING PLATE
BS BOTH SIDES
BSMT BASEMENT
BT WLD BUTT WELD
BTWN BETWEEN
C CHANNEL
C/C CENTER TO CENTER
CAM CAMBER
CAN CANOPY
CD CONSTRUCTION DOCUMENTS,
CONTRACT DOCUMENTS
CEM CEMENT
CHFR CHAMFER
CHKD CHECKED/CHECKERED
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONSTRUCTION JOINT
CJ CONTRACTION JOINT
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
cm CENTIMETER
CMU CONCRETE MASONRY UNIT
CO COMPANY
COA CITY OF ALBUQUERQUE
COL COLUMN
COM COMMON
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS , CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CRSI CONCRETE REINFORCING STEEL INSTITUTE
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
CTR CENTER
CTRL CONTROL
CU CUBIC
CU YD CUBIC YARD
D DEEP, DEPTH
D-B DESIGN-BUILD
DAT DATUM
DBL DOUBLE
DEG DEGREE
DEL DELETE
DEMO DEMOLITION
DET DETAIL
DEV DEVELOPMENT
DFTG DRAFTING
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFERENCE, DIFFERENTIAL
DIM DIMENSION
DIST DISTANCE
ABBREVIATIONSABBREVIATIONSABBREVIATIONSABBREVIATIONS
DJ DOUBLE JOIST
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DSGN DESIGN
DWG DRAWING
DWL/DWLS DOWELS
E EAST, MODULUS OF ELASTICITY
EA EACH
EE EACH END
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEM ELEMENTARY
ELEV ELEVATOR
EMBED EMBEDDED/EMBEDMENT
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EPA ENVIRONMENTAL PROTECTION AGENCY
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
ESMT EASEMENT
EST ESTIMATE
ETC ET CETERA
EW EACH WAY
EX EXAMPLE
EXC EXCAVATE
EXCL EXCLUDE
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
F/F FACE TO FACE
FAB FABRIC
FACIL FACILITY
FB FLAT BAR
FD FLOOR DRAIN
FDTN FOUNDATION
FF FAR FACE
FF EL FINISH FLOOR ELEVATION
FIN GR FINISH GRADE
FH FLAT HEAD
FIN FINISH
FIN FLR FINISH FLOOR
FLG FLANGE
FLR FLOOR
FLR SK FLOOR SINK
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB
FOS FACE OF STUD
FOW FACE OF WALL
FR FRAME
FRMG FRAMING
FS FAR SIDE
FSTNR FASTENER
FT FOOT / FEET
FT/LB FOOT/POUND
FT/LBF FOOT/POUND FORCE
FTG FOOTING
FUT FUTURE
G GIRDER
GA GAGE
GALV GALVANIZED
GALV STL GALVANIZED STEEL
GR BM GRADE BEAM
GC GENERAL CONTRACTOR
GEN GENERAL
GLU LAM GLUED LAMINATED WOOD
GLZ GLAZING
GOVT GOVERNMENT
GRTG GRATING
GT GROUT
H HIGH
HAS HEADED ANCHOR STUD
HC HOLLOW-CORE
HCP HANDICAPPED
HD HEAVY DUTY
HGR HANGER
HLDN HOLDDOWN
HORIZ HORIZONTAL
HS HIGH STRENGTH
HSKPG HOUSEKEEPING
HSS HOLLOW STRUCTURAL SECTIONS
HST HOIST
HT HEIGHT
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IF INSIDE FACE
IFS INSIDE FACE OF STUD
IN INCH
INCL INCLUDED
INFO INFORMATION
IN-LB INCH-POUND
IN-LBF INCH-POUND FORCE
INSTL INSTALL
INSUL INSULATION
INT INTERIOR
IR INSIDE RADIUS
k KIP
K THOUSAND
KB KNEE BRACE
KCJ KEYED CONTROL JOINT
KIP THOUSAND POUNDS
KIP FT THOUSAND FOOT/POUNDS
KLF KIPS PER LINEAL FOOT
KO KNOCK OUT
KOP KNOCK OUT PANEL
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L ANGLE
LAM LAMINATE
LATL LATERAL
LBF POUND-FORCE
LBR LUMBER
LBS POUND
LD BRG LOAD BEARING
LF LINEAR FEET (FOOT)
LIN LINEAR
LL LIVE LOAD
LLBB LONG LEG BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LT GA LIGHT GAGE
LT WT LIGHT WEIGHT
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
M MOMENT
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MACHINE BOLT
MC MOMENT CONNECTION
MCJ MASONRY CONTROL JOINT
MD METAL DECK
ME MECHANICAL ENGINEER
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
ML MICRO-LAMINATED
ML MONOLITHIC
MO MASONRY OPENING
MS MACHINE SCREW
MSL MEAN SEA LEVEL
MTL METAL
N NORTH
NA NOT APPLICABLE
NF NEAR FACE
NIC NOT IN CONTRACT
NM NEW MEXICO
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NTS NOT TO SCALE
O/O OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFS OUTSIDE FACE OF STUD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
OR OUTSIDE RADIUS
PAR PARALLEL, PARAPET
PART PARTIAL
PC PIECE, PORTLAND CEMENT
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCI PRECAST/PRESTRESSED CONCRETE
INSTITUTE
PED PEDESTAL
PEN PENETRATE
PERIM PERIMETER
PERP PERPENDICULAR
PH PHASE
PIL PILASTER
PL PLATE
PLAT PLATFORM
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLM PARALLAM
PLYWD PLYWOOD
POS POSITION
PP PANEL POINT
PRCST PRECAST
PREFAB PREFABRICATE
PRELIM PRELIMINARY
PREV PREVIOUS
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POST-TENSIONED
PT CONC POST-TENSIONED CONCRETE
PTN PARTITION
PVG PAVING
QTY QUANTITY
QUAD QUADRANT
R RADIUS, RISER
RC REINFORCED CONCRETE
RD ROAD, ROOF DRAIN
REC RECESSED
REF REFERENCE
REINF REINFORCE/REINFORCEMENT
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
REV REVISION
RGD INS RIGID INSULATION
RFI REQUEST FOR INFORMATION
RND ROUND
RO ROUGH OPENING
RT RIGHT
RVL REVEAL
S SOUTH
SCHEM SCHEMATIC
SCHED SCHEDULE
SD SHOP DRAWINGS
SDI STEEL DECK INSTITUTE
SDL SADDLE
SE STRUCTURAL ENGINEER
SECT SECTION
SF SQUARE FEET (FOOT)
SHT SHEET, SHAFT
SHTHG SHEATHING
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SLNT SEALANT
SM SMOOTH
SP SUMP PIT
SPA SPACE/SPACES
SPEC SPECIFICATION
SPRT SUPPORT
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SSPC STRUCTURAL STEEL PAINTING COUNCIL
ST STAIRS
STAG STAGGERED
STD STANDARD
STIF STIFFENER
STIR STIRRUP
STL STEEL
STL LNTL STEEL LINTEL
STL JST STEEL JOIST
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STR STRINGERS
STAG STAGGERED
STD STANDARD
STIF STIFFENER
STIR STIRRUP
STL STEEL
STL LNTL STEEL LINTEL
STL JST STEEL JOIST
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STR STRINGERS
STRUCT STRUCTURAL
SUB SUBSTITUTE
SUF SUFFICIENT
SUP SUPPLEMENTARY
SUPPL SUPPLEMENT
SYM SYMBOL
SYMM SYMMETRICAL
SYS SYSTEM
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TAN TANGENT
TB THRU BOLT
TEMP TEMPORARY
THD THREAD
THK THICKNESS
THRU THROUGH
TJI TRUSS JOIST INSTITUTE
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOC FTG TOP OF CONCRETE FOOTING
TOC WALL TOP OF CONCRETE WALL
TOF TOP OF FOOTING
TOG TOP OF GRATE
TOJ TOP OF JOIST
TOL TOLERANCE
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB
TOS TOP OF STEEL
TOW TOP OF WALL
TRANS TRANSVERSE
TRNBKL TURNBUCKLE
TYP TYPICAL
UBC UNIFORM BUILDING CODE
UNO UNLESS NOTED OTHERWISE
VAR VARIES
VERT VERTICAL
VIF VERIFY IN FIELD
VNR VENEER
VR VAPOR RETARDER
VRFY VERIFY
W WEST, WIDE
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WD WOOD
WF WIDE FLANGE
WF BM WIDE FLANGE BEAM
WL WIND LOAD
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
X BRACE CROSS BRACING
XXH DOUBLE EXTRA HEAVY
YD YARD
ISSUE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DATE:
FILE:
SHEET TITLE
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Architect Engineer
CONSULTANTS
STUDIO SOUTHWEST ARCHITECTS, INC.
2101 Mountain Rd. NW, Albuquerque, NM 87104
505.843.9639 Fax 505.843.9683
Web Site: www.studioswarch.com Email: mail@studioswarch.com
2013, Studio Southwest Architects, Inc.
Duplication or reproduction by any means without the express written consent of Studio Southwest Architects, Inc. is a violation of federal and International law. The information contained in this document is the intellectual property of Studio Southwest, Inc. and all rights thereto are Reserved. For exceptions refer to the Owner-Architect Agreement.
c
C U s e rs
\a m o n to y a
\D o c u m e n ts \D
P
O L V
A D
E R
A F
IR
E
S T
A T
IO
N
C G
S T
R U
C T v a m o n to y a c g
.r v t
/3
/2
:5 :5
A
M
POLVADERA FIRE
STATION
I-25 FRONTAGE ROAD NORTHBOUND
SOCORRO, COUNTY
NEW MEXICO
D062892017
6/30/2017
GHB
ADM
ABBREVIATIONS AND
LEGEND
S-001
0000S-001.RVT
Revision Schedule
No Date Description
ISSUE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DATE:
FILE:
SHEET TITLE
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Architect Engineer
CONSULTANTS
STUDIO SOUTHWEST ARCHITECTS, INC.
2101 Mountain Rd. NW, Albuquerque, NM 87104
505.843.9639 Fax 505.843.9683
Web Site: www.studioswarch.com Email: mail@studioswarch.com
2013, Studio Southwest Architects, Inc.
Duplication or reproduction by any means without the express written consent of Studio Southwest Architects, Inc. is a violation of federal and International law. The information contained in this document is the intellectual property of Studio Southwest, Inc. and all rights thereto are Reserved. For exceptions refer to the Owner-Architect Agreement.
c
C U s e rs
\a m o n to y a
\D o c u m e n ts \D
P
O L V
A D
E R
A F
IR
E
S T
A T
IO
N
C G
S T
R U
C T v a m o n to y a c g
.r v t
/3
/2
:5 :5
A
M
POLVADERA FIRE
STATION
I-25 FRONTAGE ROAD NORTHBOUND
SOCORRO, COUNTY
NEW MEXICO
D062892017
6/30/2017
GHB
ADM
GENERAL STRUCTURAL
NOTES
S-002
0000S-002.RVT
GENERAL FOUNDATION NOTES GENERAL STRUCTURAL NOTES GENERAL STRUCTURAL NOTES GENERAL STRUCTURAL NOTES
FOUNDATION NOTES
GENERAL:
A SUBSURFACE SOIL INVESTIGATION HAS BEEN MADE BY WESTERN TECHNOLOGIES, PROJECT NO. 3227JD077.
A REPORT OF THAT INVESTIGATION DATED MARCH 24, 2017 IS AVAILABLE FOR VIEWING IN THE PROJECT
MANUAL.
THE FOUNDATION SYSTEM FOR THIS PROJECT IS CONCRETE SLAB-ON-GRADE WITH TURNED DOWN PERIMETER
FOOTINGS OVER ENGINEERED FILL.
ADDITIONAL INFORMATION CONCERNING SPECIFIC SOIL CONDITIONS TO BE ENCOUNTERED IS AVAILABLE IN
THE SOILS REPORTS AND SHALL BE REVIEWED BY THE CONTRACTOR.
FIELD OBSERVATION AND TESTS:
THE OWNER SHALL EMPLOY THE SERVICES OF A REGISTERED, LICENSED GEOTECHNICAL ENGINEER TO OBSERVE ALL CONTROLLED EARTHWORK. THE GEOTECHNICAL ENGINEER SHALL PROVIDE CONTINUOUS ON- SITE OBSERVATION BY EXPERIENCED PERSONNEL DURING CONSTRUCTION OF CONTROLLED EARTHWORK.
THE CONTRACTOR SHALL NOTIFY THE GEOTECHNICAL ENGINEER AT LEAST TWO WORKING DAYS IN ADVANCE
OF ANY FIELD OPERATIONS OF THE CONTROLLED EARTHWORK.
TESTS OF MATERIALS SHALL BE MADE AT THE FOLLOWING MINIMUM RATES. THE ON-SITE GEOTECHNICAL
ENGINEER SHALL DETERMINE THE ACTUAL TESTING RATES:
ONE FIELD DENSITY TEST PER 2500 SQUARE FEET OF COMPACTED SUBGRADE, PRIOR TO PLACING
STRUCTURAL FILL OR SLAB-ON-GRADE, WITH A MINIMUM OF 3 TESTS.
ONE FIELD DENSITY TEST PER 2500 SQUARE FEET OF STRUCTURAL FILL PLACED OR EACH HORIZONTAL
LAYER OF STRUCTURAL FILL, WHICHEVER IS GREATER.
ONE MOISTURE-DENSITY CURVE FOR EACH TYPE OF MATERIAL USED, AS INDICATED BY THE SIEVE
ANALYSIS AND THE PLASTICITY INDEX.
THE GEOTECHNICAL ENGINEER SHALL SUBMIT THE RESULTS OF ALL REQUIRED TESTS.
CLEARING AND GRUBBING:
REMOVE ALL BRUSH, RUBBISH, GRASS, AND GRASS ROOTS FROM THE CONSTRUCTION AREA.
REMOVE STUMPS, MATTED ROOTS AND ROOTS LARGER THAN 2 INCHES IN DIAMETER WITHIN 6 INCHES OF THE
SURFACE OF AREAS ON WHICH FILL AND/OR FOOTINGS ARE TO BE CONSTRUCTED.
REMOVE ALL TOPSOIL FROM THE CONSTRUCTION AREA. THIS MATERIAL SHALL NOT BE USED AS FILL MATERIAL, BUT MAY BE STOCKPILED AND LATER USED IN THE TOP 6 INCHES OF FILL OUTSIDE THE BUILDING
PAD.
SITE, SUBFLOOR AND BEARING SURFACE PREPARATION:
A REPRESENTATIVE OF THE GEOTECHNICAL ENGINEER SHALL BE PRESENT TO CONFIRM COMPLETE
EXCAVATION OF ANY UNCONTROLLED FILL.
OVEREXCAVATE ALL SOILS UNDERLYING FOOTINGS AND ALL UNCONTROLLED FILL TO A MINIMUM DEPTH OF 2
FEET, OR 2 FEET BELOW EXISTING SITE GRADES, WHICHEVER IS GREATER.
SCARIFY ALL EXPOSED SUBGRADE SOILS TO A DEPTH OF 10 INCHES, MOISTEN TO OPTIMUM MOISTURE
CONTENT AND COMPACT TO THE DENSITY SPECIFIED HEREINAFTER.
PLACE ALL STRUCTURAL FILL IN APPROXIMATELY HORIZONTAL LAYERS NOT GREATER THAN 10 INCHES IN LOOSE THICKNESS, MOISTEN TO OPTIMUM MOISTURE CONTENT (+3%/-2%) AND COMPACT TO DENSITY
SPECIFIED HEREINAFTER.
ALL EARTHWORK FOR THE BUILDING PAD SHALL EXTEND A MINIMUM OF 2 FEET BEYOND THE PERIMETER
FOOTINGS.
STRUCTURAL FILL REQUIREMENTS:
GRADATION (ASTM D422):
SIEVE SIZE PERCENT PASSING BY WEIGHT
6" 100 4” 85-100 3/4" 70-100
NO. 4 50-100
NO. 200 15 MAXIMUM
PLASTICITY INDEX (ASTM D4318): NON-PLASTIC
MAXIMUM SOLUBLE SULFATES: 0.10%
MATERIAL LARGER THAN 6 INCHES SHALL NOT BE PLACED IN THE STRUCTURAL FILL, AND MATERIAL LARGER THAN 4 INCHES SHALL NOT BE PLACED WITHIN TWELVE INCHES OF THE BEARING SURFACES OF SLABS OR
FOUNDATIONS.
NO BRUSH, SOD, FROZEN MATERIAL OR OTHER UNSUITABLE MATERIAL SHALL BE PLACED IN THE STRUCTURAL FILL. MATERIAL SHALL BE PLACED IN SUCH A MANNER AS TO RESULT IN A UNIFORMLY COMPACTED FILL.
IMPORTED FILL OR EXISTING SOILS MAY BE USED FOR THE STRUCTURAL FILL. HOWEVER, IN ORDER TO MEET THE ABOVE CRITERIA, THE ON SITE SOILS WILL PROBABLY NEED TO BE MIXED WITH IMPORTED FILL. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE MOST APPROPRIATE METHOD TO PROVIDE THE
REQUIRED STRUCTURAL FILL.
COMPACTION REQUIREMENTS:
IN ACCORDANCE WITH ASTM D1557 (MODIFIED PROCTOR), SUBGRADE SOILS AND STRUCTURAL FILL MATERIALS SHALL BE COMPACTED TO THE FOLLOWING PERCENTAGES OF THE MAXIMUM DRY DENSITY AT OPTIMUM
MOISTURE CONTENT:
MINIMUM
MATERIAL PERCENT COMPACTION
STRUCTURAL FILL IN THE BUILDING AREA 95
SUBBASE FOR SLAB SUPPORT 95
SUBGRADE BELOW STRUCTURAL FILL 95
MISCELLANEOUS BACKFILL 90
Revision Schedule
No Date Description
CODES AND MANUALS:
IBC-09 INTERNATIONAL BUILDING CODE 2009
ASCE/SEI 7-05 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
AISC 360-05 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
AISC MANUAL OF STEEL CONSTRUCTION 13TH EDITION
ACI 318-08 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
AWS D1.1-04 STRUCTURAL WELDING CODE – STEEL
AWS D1.3-08 STRUCTURAL WELDING CODE – SHEET STEEL
DESIGN CRITERIA:
VERTICAL:
ROOF LIVE LOAD: LR = 20*R1*R2 20 PSF
REDUCTION FACTOR BASED ON TRIB AREA R1=1.0
REDUCTION FACTOR BASED ON ROOF SLOPE R2=1.0
SNOW LOAD
GROUND SNOW LOAD PG=10 PSF
FLAT ROOF SNOW LOAD** PF=15 PSF
SNOW EXPOSURE FACTOR CE=1.0
SNOW LOAD IMPORTANCE FACTOR IS=1.0
THERMAL FACTOR CT=1.0
**INCLUDES 5 PSF RAIN-ON SNOW SURCHARGE LOAD
HORIZONTAL:
WIND
BASIC WIND SPEED 90 MPH
WIND IMPORTANCE FACTOR IW = 1.25
BUILDING CATEGORY IV
EXPOSURE C
SEISMIC
SEISMIC IMPORTANCE FACTOR IS = 1.5
MAPPED SPECTRAL RESPONSE ACCELERATIONS
SHORT PERIOD SS=0.500G
1 SECOND PERIOD S1=0.138G
SITE CLASS D
SPECTRAL RESPONSE COEFFICIENTS
SHORT PERIOD SDS=0.467G
1 SECOND PERIOD SD1=0.207G
SEISMIC DESIGN CATEGORY D
RESPONSE MODIFICATION FACTOR R = [5]
DESIGN BASE SHEAR V = 0.000W
ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF
FROST DEPTH = 18 INCHES
FUTURE BUILDING EXPANSION: NONE
GENERAL:
STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN
CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS
INTO THE SHOP DRAWINGS AND FIELD WORK.
COORDINATE DIMENSIONS OF ALL OPENINGS, DEPRESSIONS, BLOCKOUTS, ETC. WITH ARCHITECTURAL DRAWINGS, DRAWINGS FROM OTHER DISCIPLINES, PROJECT SHOP DRAWINGS, AND FIELD CONDITIONS PRIOR TO SHOP DRAWING SUBMITTAL THE STRUCTURAL DRAWINGS ONLY REPRESENT A PORTION OF THE
REQUIREMENTS FOR THE PROJECT.
SEE ARCHITECTURAL PLANS FOR INTERIOR NON-BEARING PARTITION WALLS. PARTITION FRAMING SHALL BE CONNECTED TO THE PRIMARY STRUCTURE TO ALLOW FOR VERTICAL LIVE LOAD DEFLECTIONS OF SPAN/360
FOR FLOOR FRAMING AND SPAN/240 FOR ROOF FRAMING.
CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD.
SHOP DRAWINGS SHALL BE FURNISHED AND REVIEWED BEFORE ANY FABRICATION OR ERECTION IS STARTED. THE CONTRACTOR SHALL REVIEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO THE ARCHITECT FOR REVIEW. POORLY EXECUTED SHOP DRAWINGS WILL BE REJECTED AND SHALL BE
RESUBMITTED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SAFE AND ADEQUATE SHORING FOR ALL PARTS
OF THE STRUCTURE DURING CONSTRUCTION.
TEMPORARY PROVISIONS SHALL BE MADE FOR STRUCTURAL STABILITY DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION.
NOTCHING OR CUTTING ANY STRUCTURAL MEMBER IN THE FIELD IS PROHIBITED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADHERING TO ALL APPLICABLE STANDARDS SET FORTH BY
OSHA
PROTECTION: PROPER PRECAUTIONS SHALL BE TAKEN AT ALL TIMES TO PROTECT VEHICULAR AND PEDESTRIAN TRAFFIC FROM ANY DAMAGE OR INJURY WHICH MAY BE CAUSED, EITHER DIRECTLY OR INDIRECTLY, BY THE WORK INCLUDED ON THESE DRAWINGS. SUCH PRECAUTIONS SHALL INCLUDE THE ERECTION AND MAINTENANCE OF FENCES, BARRICADES, RAILINGS, GUARDS, SIGNS, COVERINGS, LIGHTS, AND OTHER PRECAUTIONS AS MAY BE REQUIRED. IF AT ANY TIME, IN THE OPINION OF THE OWNER OR THE OWNER’S REPRESENTATIVE, PROPER PRECAUTIONS ARE NOT BEING TAKEN TO SECURE THIS PROTECTION, THE CONTRACTOR SHALL AT NO ADDITIONAL COST TO THE OWNER, INSTALL AND MAINTAIN SUCH
ADDITIONAL PROTECTION AS MAY BE DIRECTED BY THE OWNER.
POLLUTION CONTROLS: USE WATER SPRINKLING, TEMPORARY ENCLOSURES, AND OTHER SUITABLE METHODS TO LIMIT DUST AND DIRT RISING AND SCATTERING IN THE AIR TO LOWEST PRACTICAL LEVEL.
COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION.
DO NOT SCALE DRAWINGS.
CAST-IN-PLACE CONCRETE:
ALL CONCRETE SHALL CONFORM TO THE SPECIFICATIONS FOR STRUCTURAL CONCRETE, ACI 301-05.
ALL EXPOSED EDGES OF CONCRETE SHALL HAVE A 3/4" CHAMFER UNLESS NOTED OTHERWISE.
NORMALWEIGHT CONCRETE:
A. F'C = 4500 PSI @ 28 DAYS - ALL EXPOSED EXTERIOR CONCRETE FLAT WORK AND RETAINING WALLS (I.E., SLABS, EQUIPMENT PADS, WALLS, ETC.).
EXTERIOR CONCRETE SHALL MEET EXPOSURE CATEGORY AND CLASS F1 ACCORDING TO ACI 318 TABLE 4.2.1.
B. F'C = 3000 PSI @ 28 DAYS - ALL INTERIOR CONCRETE (I.E. FOOTINGS, PEDESTALS, TIE BEAMS, GRADE
BEAMS, RETAINING WALLS, ETC.).
C. F'C = 3000 PSI @ 28 DAYS - ALL INTERIOR SLABS ON GRADE, UNLESS NOTED OTHERWISE.
CONCRETE MIX DESIGNS (INCLUDING AIR CONTENT, WATER TO CEMENT RATIOS, AND OTHER CRITERIA) SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN ACI 318 TABLE 4.3.1, BASED ON THE EXPOSURE CATEGORIES AND CLASSES DEFINED IN ACI 318 TABLE 4.2.1. USE AIR ENTRAINING ADMIXTURE IN ALL EXTERIOR CONCRETE. AIR CONTENT IN FIRE RATED SLABS SHALL ALSO COMPLY WITH THE REQUIREMENTS
IN THE SPECIFIED UL LISTING.
COLD WEATHER CONCRETING: PROTECT CONCRETE WORK FROM PHYSICAL DAMAGE OR REDUCED
STRENGTH CAUSED BY FROST, FREEZING OR LOW TEMPERATURES. COMPLY WITH ACI 306.1.
HOT WEATHER CONCRETING: WHEN HOT WEATHER CONDITIONS EXIST THAT WOULD IMPAIR THE QUALITY AND STRENGTH OF THE CONCRETE, REDUCE DELIVERY TIME OF READY MIX CONCRETE, LOWER THE TEMPERATURE OF MATERIALS, OR ADD RETARDER TO ENSURE THAT THE CONCRETE IS PLASTIC.
RETEMPERING WITH WATER IS NOT ALLOWED. COMPLY WITH ACI 305R.
THE CONTRACTOR SHALL NOT CAST CONCRETE STEM WALLS OR RETAINING WALLS AGAINST EXCAVATED
VERTICAL SOIL SURFACES.
ALL CONCRETE EXPOSED TO GROUND SHALL BE MANUFACTURED WITH PORTLAND CEMENT TYPE II OR TYPE V.
REINFORCING STEEL:
ALL REINFORCING STEEL SHALL BE FABRICATED AND PLACED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-08), AND DETAILS AND DETAILING OF CONCRETE
REINFORCEMENT (ACI 315-99).
ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60; EXCEPT STIRRUPS, TIES AND INDICATED
FIELD-BENT BARS, WHICH SHALL CONFORM TO ASTM A615 GRADE 40.
ALL WELDED WIRE FABRIC SHALL BE DEFORMED AND SHALL CONFORM TO ASTM A479. PROVIDE IN FLAT
SHEETS ONLY.
TENSION AND COMPRESSION LAPS IN REINFORCING SHALL CONFORM TO THE LAP SPLICE SCHEDULE ON SHEET [S-601] AND BE IN ACCORDANCE WITH ACI 318, CHAPTER 12, UNLESS NOTED OTHERWISE.
ALL HORIZONTAL REINFORCING IN FOOTINGS, WALLS AND BEAMS SHALL BE CONTINUOUS AROUND CORNERS OR HAVE BENT (CORNER) BARS OF THE SAME SIZE AND SPACING AS THE HORIZONTAL BARS AND LAP 30 BAR
DIAMETERS (24" MINIMUM).
CONCRETE COVER FOR REINFORCING SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: {Fire Rated Slabs May Require Additional Cover}
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3"
B. CONCRETE CAST AGAINST FORMS BUT EXPOSED TO EARTH OR WEATHER:
1. BARS LARGER THAN NO. 5: 2"
2. BARS NO. 5 OR SMALLER: 1 1/2"
C. SLAB ON GRADE: 2 1/2" FROM TOP OF SLAB
FORM TIES SHALL BE EITHER OF THE THREADED OR SNAP-OFF TYPE SO THAT NO METAL WILL BE LEFT WITHIN 1 INCH OF THE SURFACE OF THE WALL. FOLLOWING REMOVAL OF FORM TIES, RECESSES ARE TO BE
CAREFULLY FILLED AND POINTED WITH MORTAR.
REINFORCING SHALL NOT BE TACK WELDED OR WELDED IN ANY MANNER UNLESS SPECIFICALLY DETAILED
ON THE STRUCTURAL PLANS.
BAR SUPPORTS AND SPACERS FOR REINFORCING SHALL BE PROVIDED IN ACCORDANCE WITH ACI 315-99.
REINFORCING SHALL BE SECURELY TIED TO SUPPORTS.
CHAIRS WITH 22 GAGE SAND PLATES OR PRECAST BLOCKS SHALL BE PROVIDED FOR ALL REINFORCING OF
CONCRETE IN CONTACT WITH GRADE.
PRE-ENGINEERED METAL BUILDING:
FOUNDATION CONFIGURATION AND SIZES SHOWN ON THESE DRAWINGS ARE BASED ON PRELIMINARY DESIGN CALCULATIONS. THESE SIZES MAY REQUIRE MODIFICATIONS PER THE METAL BUILDING
MANUFACTURER'S FINAL GRAVITY AND LATERAL DESIGN CALCULATIONS.
THE METAL BUILDING MANUFACTURER SHALL PROVIDE FINAL GRAVITY AND LATERAL DESIGN CALCULATIONS
FOR APPROVAL PRIOR TO THE COMMENCEMENT OF FOUNDATION EARTHWORK.
THE BUILDING SHALL BE A MANUFACTURER'S STANDARD PREFABRICATED METAL STRUCTURE OF THE APPROXIMATE INSIDE AREA SHOWN, EXCEPT AS NOTED. RIGID FRAMES SHALL BE SPACED AS SPECIFIED ON
THE DRAWINGS, BUT OVERALL DIMENSIONS AND CONSTRUCTION DETAILS MAY VARY TO SUIT
MANUFACTURER'S STANDARD DESIGN. MINIMUM WEB THICKNESS OF RIGID FRAMES SHALL BE 3/16".
THE BUILDING SHALL BE DESIGNED AND FABRICATED ACCORDING TO AISC, MBMA AND AISI SPECIFICATIONS.
THE DIMENSIONAL TOLERANCES APPLICABLE TO ROLLED FORM STEEL UNDER THE LATEST EDITION OF THE AISC "STANDARD MILL PRACTICE" SECTION SHALL BE REQUIRED IN THE FABRICATION OF THE STEEL
BUILDING FRAMES.
THE BUILDING FRAME SHALL BE DESIGNED TO LIMIT THE LATERAL DEFLECTION TO H/120 INCH AT THE
BUILDING EAVE FOR THE SPECIFIED BASIC WIND SPEED.
THE BUILDING SHALL BE DESIGNED TO SUPPORT ALL MECHANICAL EQUIPMENT INCLUDING HEATERS, SPRINKLERS, EXHAUST SYSTEMS AND ALL OTHER DEVICES. ADDITIONAL GIRTS OR PURLINS SHALL BE PLACED IN CONVENIENT LOCATIONS FOR ATTACHMENT OF ALL MECHANICAL EQUIPMENT. THE CONTRACTOR SHALL COORDINATE THE MECHANICAL LOADS WITH THE METAL BUILDING MANUFACTURER AND THE
MECHANICAL DRAWINGS.
DESIGN LOADS SHALL CONFORM WITH THESE GENERAL NOTES. LOAD COMBINATIONS SHALL COMPLY WITH
MBMA SPECIFICATIONS.
ANCHOR BOLTS SHOWN ON THESE DRAWINGS ARE BASED ON PRELIMINARY DESIGN CALCULATIONS. THESE SIZES MAY REQUIRE MODIFICATIONS PER THE METAL BUILDING MANUFACTURER'S FINAL GRAVITY AND
LATERAL DESIGN CALCULATIONS.
PREPARE THE SHOP DRAWINGS AND CALCULATIONS UNDER THE SEAL OF A PROFESSIONAL STRUCTURAL
ENGINEER REGISTERED IN THE STATE OF NEW MEXICO.
COORDINATE WITH ARCHITECTURAL DRAWINGS.
SPECIAL INSPECTION:
THE OWNER SHALL PROVIDE FOR SERVICES OF A CERTIFIED INSPECTOR (APPROVED BY THE BUILDING OFFICIAL OR THE ENGINEER OF RECORD) IN ACCORDANCE WITH CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE FOR THE SPECIAL INSPECTION ITEMS NOTED ON SHEET S-003.
DEFERRED SUBMITTALS:
THE DEFERRED SUBMITTALS LISTED BELOW ARE THOSE PORTIONS OF THE DESIGN THAT ARE NOT COMPLETED AT THE TIME OF APPLICATION AND ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL AND APPROVED PRIOR TO THE INSTALLATION OF THOSE ITEMS. THE MANUFACTURER, CONSULTANT, OR CONTRACTOR, AS APPROPRIATE, SHALL PROVIDE SUBMITTALS TO THE ENGINEER OF RECORD FOR REVIEW
FOR THE FOLLOWING ITEMS:
PRE-ENGINEERED METAL BUILDING
VERIFICATION AND INSPECTION TASK
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH
AND HAVE REACHED PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF CONTROLLED
FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT
THICKNESS DURING PLACEMENT AND COMPACTION OF
CONTROLLED FILL.
5. PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE
SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED
PROPERLY.
SPECIAL
INSPECTION
REQUIRED
Y/N
CONTINUOUS
DURING TASK
LISTED
PERIODICALLY
DURING
TASK
LISTED
IBC
REFERENCE
SPECIAL INSPECTION AND VERIFICATION OF SOILS
----- X 1704.7
----- X 1704.7
----- X 1704.7
X ----- 1704.7
----- X 1704.7
Y
Y
Y
Y
Y
SCHEDULE OF STRUCTURAL SPECIAL INSPECTIONS
1. SPECIAL INSPECTIONS / TESTING -“SPECIAL STRUCTURAL INSPECTION” SHALL NOT RELIEVE THE OWNER OR THEIR AGENT FROM
HAVING THE INSPECTIONS OF THE JURISDICTION BUILDING DEPARTMENT PER SECTION 110 OF THE IBC PERFORMED. BOTH THE JURISDICTION BUILDING DEPARTMENT INSPECTIONS AND “SPECIAL STRUCTURAL INSPECTION” SHALL BE PERFORMED.
2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE JURISDICTION BUILDING OFFICIAL AND SPECIAL
INSPECTOR WHEN WORK IS READY FOR INSPECTION.
3. REPORTING FOR SPECIAL INSPECTION - SPECIAL INSPECTION AND TESTING REPORTS SHALL BE COMPLETED AND DISTRIBUTED AT THE COMPLETION OF EACH TASK. IF A TASK IS TO TAKE LONGER THAN (3) DAYS, PROVIDE REPORTS FOR EACH DAY. PROVIDE COPIES OF REPORTS TO: CONTRACTOR, OWNER, ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. SPECIAL INSPECTOR TO KEEP A NON- COMPLIANCE LIST DOCUMENTING ITEMS INSPECTED NOT MEETING APPROVED CONSTRUCTION DOCUMENTS AND
WHEN / HOW RESOLVED.
4. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING CONSTRUCTION DOCUMENTS FOR ADDITIONAL NON-STRUCTURAL
SPECIAL INSPECTION ITEMS.
5. SPECIAL INSPECTION OF SHOP FABRICATED MEMBERS AND ASSEMBLIES SHALL BE IN ACCORDANCE WITH SECTION 1704.2, UNLESS
FABRICATOR IS APPROVED TO PERFORM WORK WITHOUT SPECIAL INSPECTION.
6. IN ACCORDANCE WITH IBC CHAPTER 17, THE WORK IN THE FOLLOWING TABLES REQUIRE SPECIAL INSPECTIONS AND TESTING:
7. DEFINITIONS:
SPECIAL INSPECTION: INSPECTION AS HEREIN REQUIRED BY A QUALIFIED SPECIAL INSPECTOR COMPETENT WITH THE MATERIALS, INSTALLATION, FABRICATION, ERECTION OR PLACEMENT OF COMPONENTS AND CONNECTIONS REQUIRING SPECIAL EXPERTISE TO ENSURE COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED STANDARDS ( SEE SECTION 1704).
CONTINUOUS SPECIAL INSPECTION: FULL-TIME OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED
SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED.
PERIODIC SPECIAL INSPECTION: THE PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT
THE COMPLETION OF THE WORK.
1. INSPECTION OF REINFORCING STEEL,
INCLUDING PRESTRESSING TENDONS
AND PLACEMENT.
2. INSPECTION OF REINFORCING STEEL
WELDING IN ACCORDANCE WITH TABLE
1704.3, ITEM 5b.
3. INSPECT BOLTS TO BE INSTALLED IN
CONCRETE PRIOR TO AND DURING
PLACEMENT OF CONCRETE WHERE
ALLOWABLE LOADS HAVE BEEN
INCREASED OR WHERE STRENGTH
DESIGN IS USED.
5. VERIFYING USE OF REQUIRED DESIGN
MIX.
6. AT THE TIME FRESH CONCRETE IS
SAMPLED TO FABRICATE SPECIMENS
FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS AND
DETERMINE THE TEMPERATURE OF THE
CONCRETE.
7. INSPECTION OF CONCRETE AND
SHOTCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
8. INSPECTION FOR MAINTENANCE OF
SPECIFIED CURING TEMPERATURE
AND TECHNIQUES.
9. INSPECTION OF PRESTRESSED
CONCRETE:
a. APPLICATION OF PRESTRESSING
FORCES.
b. GROUTING OF BONDED
PRESTRESSING TENDONS IN THE
SEISMIC-FORCE RESISTING
SYSTEM.
10. ERECTION OF PRECAST CONCRETE
MEMBERS.
11. VERIFICATION OF IN-SITU CONCRETE
STRENGTH, PRIOR TO STRESSING OF
TENDONS IN POST-TENSIONED
CONCRETE AND PRIOR TO REMOVAL
OF SHORES AND FORMS FROM BEAMS
AND STRUCTURAL SLABS.
12. INSPECT FORMWORK FOR SHAPE,
LOCATION AND DIMENSIONS OF THE
CONCRETE MEMBER BEING FORMED.
VERIFICATION AND INSPECTION
SPECIAL
INSPECTION
REQUIRED Y/N
Y
Y
Y
Y
Y
Y
Y
N
N
N
Y
Y
1911.5, 1912.1
ACI318: 8.1.3,
21.2.8
4. INSPECTION OF ANCHORS INSTALLED
IN HARDENED CONCRETE.
Y 1912.1
ACI318: 3.8.6, 8.1.3,
21.2.8
1913.6, 1913.7, 1913.8
1913.9
ACI 318: 18.20
ACI 318: 18.18.4
SPECIAL INSPECTION AND VERIFICATION OF
CONCRETE CONSTRUCTION
FREQUENCY OF INSPECTION
CONTINUOUS
DURING
TASK LISTED
PERIODICALLY
DURING TASK
LISTED
IBC SECTION
REFERENCE FOR CRITERIA
REFERENCED
STANDARD
----- X 1913.4
ACI 318: 3.5,
7.1-7.7
AWS D1.4
ACI 318: 3.5.2
X -----
----- X
----- X 1904.2.2, 1913.2, 1913.3
ACI 318: CH. 4,
5.2-5.4
X ----- 1913.10
ASTM C 172
ASTM C 31
ACI 318: 5.6, 5.8
X ----- ACI 318: 5.9,
5.10
----- X ACI 318: 5.11- 5.13
X
X
----- X ----- ACI 318: CH. 16
----- X ----- ACI 318: 6.2
----- X ----- ACI 318: 6.1.1
VERIFICATION AND INSPECTION
1. MATERIAL VERIFICATION OF HIGH-STRENGTH BOLTS, NUTS AND WASHERS:
a. IDENTIFICATION OF ASTM
STANDARDS SPECIFIED IN THE
APPROVED CONSTRUCTION
DOCUMENTS.
b. MANUFACTURER'S CERTIFICATE OF
COMPLIANCE REQUIRED.
2. INSPECTION OF HIGH-STRENGTH BOLTING:
a. SNUG-TIGHT JOINTS.
b. PRETENSIONED AND SLIP-CRITICAL
JOINTS USING TURN-OF-NUT
MATCHMARKING, TWIST-OFF BOLT
OR DIRECT TENSION INDICATOR
METHODS OF INSTALLATION.
3. MATERIAL VERIFICATION OF STRUCTURAL STEEL AND COLD-FORMED STEEL DECK:
a. FOR STRUCTURAL STEEL, IDENTIFICATION MARKINGS TO
CONFORM TO AISC 360.
b. FOR OTHER STEEL, IDENTIFICATION MARKING TO
CONFORM TO ASTM STANDARDS
SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS.
4. MATERIAL VERIFICATION OF WELD FILLER MATERIALS:
a. IDENTIFICATION MARKINGS TO
CONFORM TO AWS SPECIFICATION
IN THE APPROVED CONSTRUCTION
DOCUMENTS.
b. MANUFACTURER'S CERTIFICATE OF
COMPLIANCE REQUIRED.
5. INSPECTION OF WELDING:
a. STRUCTURAL STEEL AND COLD FORMED STEEL DECK :
1) COMPLETE AND PARTIAL
PENETRATION GROOVE WELDS.
2) MULTIPASS FILLET WELDS.
3) SINGLE-PASS FILLET WELDS >5/16"
5) SINGLE-PASS FILLET WELDS≤5/16"
6) FLOOR AND ROOF DECK WELDS.
c. REINFORCING STEEL:
1) WELDABILITY OF REINFORCING
STEEL OTHER THAN ASTM A 706.
2) REINFORCING STEEL RESISTING
FLEXURAL AND AXIAL FORCES IN
INTERMEDIATE AND SPECIAL
MOMENT FRAMES, AND BOUNDARY
ELEMENTS OF SPECIAL REIN-
FORCED CONCRETE SHEAR WALLS.
3) SHEAR REINFORCEMENT.
4) OTHER REINFORCING STEEL.
6. INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE :
SPECIAL
INSPECTION
REQUIRED Y/N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
Y
Y
Y
a. DETAILS SUCH AS BRACING AND
STIFFENING.
b. MEMBER LOCATIONS.
c. APPLICATION OF JOINT DETAILS AT
EACH CONNECTION.
AISC 360, SEC. A3.3
AND APPLICABLE
ASTM MATERIALS
AND STANDARDS.
c. PRETENSIONED AND SLIP-CRITICAL
JOINTS USING TURN-OF-NUT
WITHOUT MATCHMARKING OR
CALIBRATED WRENCH METHODS OF
INSTALLATION.
Y
AISC 360, SECTION
M2.5
APPLICABLE ASTM
MATERIAL
STANDARDS
Y
AISC 360,
SECTION M2.5
c. MANUFACTURER'S CERTIFIED
TEST REPORTS.
AISC 360, SEC. A3.5
AND APPLICABLE
AWS A5
DOCUMENTS
4) PLUG AND SLOT WELDS.Y
AWS D1.4
ACI 318:
SECTION 3.5.2
b. STEEL HEADED SHEAR STUDS (TYPE B STUDS IN COMPOSITE BEAM CONSTRUCTION) :
2) STUD SIZE AND COUNT
N
3) STUD LOCATION ON BEAM AND
WITHIN DECK VALLEYS
4) WELD VERIFICATION
1) QUALIFICATION OF WELD
APPLICATION PROCEDURE
N
N
N
AWS D1.1
AISC 360 P.
16.1-88
CONTINUOUS
DURING TASK
LISTED
PERIODICALLY
DURING
TASK
LISTED
SPECIAL INSPECTION AND VERIFICATION OF STEEL CONSTRUCTION
FREQUENCY OF INSPECTION
IBC
SECTION
REFERENCED
STANDARD
REFERENCE FOR CRITERIA
----- X -----
----- X ----- -----
----- X
----- X
X -----
1704.3.3
AISC 360, SECTION
M2.5
----- X
----- X
----- X
----- X -----
----- X ----- -----
X -----
X -----
X -----
X -----
----- X
----- X
1704.3.1 AWS D1.1
----- AWS D1.3
X ----- ----- AWS D1.1
SEC 7.6
----- X ----- -----
----- X -----
----- X ----- AWS D1.1
SEC 7.8
----- X
X ----- -----
X -----
----- X
----- X
----- X
----- X
1704.3.2 -----
1. WHERE REINFORCEMENT COMPLYING WITH ASTM A 615 IS USED
TO RESIST EARTHQUAKE-INDUCED FLEXURAL AND AXIAL FORCES
IN SPECIAL MOMENT FRAMES, SPECIAL STRUCTURAL WALLS AND
COUPLING BEAMS CONNECTING SPECIAL STRUCTURAL WALLS, IN
STRUCTURES ASSIGNED TO SDC = B, C, D, E, OR F AS DEFINED IN
SECTION 1613, THE REINFORCEMENT SHALL COMPLY WITH
SECTION 21.1.5.2 OF ACI 318. CERTIFIED MILL TEST REPORTS SHALL
BE PROVIDED FOR EACH SHIPMENT OF SUCH REINFORCEMENT.
WHERE REINFORCEMENT COMPLYING WITH ASTM A 615 IS WELDED,
CHEMICAL TESTS SHALL BE PERFORMED TO DETERMINE
WELDABILITY IN ACCORDANCE WITH SECTION 3.5.2 OF ACI 318.
VERIFICATION AND INSPECTION TASK
3. REINFORCING AND PRESTRESSING STEEL CERTIFIED MILL
TEST REPORTS SHALL BE PROVIDED FOR EACH SHIPMENT
OF REINFORCING STEEL.
4. STRUCTURAL STEEL
SPECIAL
INSPECTION
REQUIRED
Y/N
N
N
Y
2. STRUCTURAL STEEL IN STRUCTURES IN SDC = C, D, E, OR FY
CONTINUOUS
DURING TASK
LISTED
PERIODICALLY
DURING
TASK
LISTED
STRUCTURAL TESTING FOR SEISMIC RESISTANCE
OF SEISMIC FORCE RESISTING SYSTEMS
FREQUENCY OF INSPECTION
REFERENCE
FOR
CRITERIA
IBC SECTION
X ----- 1708.2
PER AISC 341 PER AISC 341 1708.3
----- X
1708.2 &
1708.3
PER AISC 341 PER AISC 341
1708.2 &
1708.4
ISSUE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DATE:
FILE:
SHEET TITLE
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Architect Engineer
CONSULTANTS
STUDIO SOUTHWEST ARCHITECTS, INC.
2101 Mountain Rd. NW, Albuquerque, NM 87104
505.843.9639 Fax 505.843.9683
Web Site: www.studioswarch.com Email: mail@studioswarch.com
2013, Studio Southwest Architects, Inc.
Duplication or reproduction by any means without the express written consent of Studio Southwest Architects, Inc. is a violation of federal and International law. The information contained in this document is the intellectual property of Studio Southwest, Inc. and all rights thereto are Reserved. For exceptions refer to the Owner-Architect Agreement.
c
C U s e rs
\a m o n to y a
\D o c u m e n ts \D
P
O L V
A D
E R
A F
IR
E
S T
A T
IO
N
C G
S T
R U
C T v a m o n to y a c g
.r v t
/3
/2
:5 :5
A
M
POLVADERA FIRE
STATION
I-25 FRONTAGE ROAD NORTHBOUND
SOCORRO, COUNTY
NEW MEXICO
D062892017
6/30/2017
GHB
ADM
SPECIAL INSPECTION
TABLES
S-003
0000S-003.RVT
1. DIMENSIONS ARE TO THE FACE OF CONCRETE AND GRIDLINES
UNLESS NOTED OTHERWISE.
2. SEE SHEET S-601 FOR SCHEDULES AND TYPICAL FRAMING
DETAILS.
G
F
E
D
C
B
A
1 2 3 4 5 6
20' - 0" 20' - 0" 20' - 0" 20' - 0" 20' - 0"
100' - 0"
/4
4"
SG8
A4
S-601
SG8
A4
S-601
SG8
A4
S-601
10" 38' - 4" 10"
/2
10" 78' - 4" 10"
/2
FIN FLR= 100' - 0"
S
LO
P E
S
LO
P E
F36 F60F60F60
F60
F36
F60 F60 F60 F60 F36
7'
/2
F36
BP1
F36
BP1
S-301
B3 TYP
C4
S-301
B4
S-301
TYP
A4
S-301
TYP
A4
S-301
TYP
B4
S-301
TYP
C3
S-301
C3
S-301
F36
F36
C J
CJ
C J
C J
C J
CJ
C J
CJ
C J
C J
C J
CJ
CJ
F36
CJ
CJ
CJ
C J
C J
C J
C J
C J
C J
C J
C J
ISSUE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DATE:
FILE:
SHEET TITLE
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Architect Engineer
CONSULTANTS
STUDIO SOUTHWEST ARCHITECTS, INC.
2101 Mountain Rd. NW, Albuquerque, NM 87104
505.843.9639 Fax 505.843.9683
Web Site: www.studioswarch.com Email: mail@studioswarch.com
2013, Studio Southwest Architects, Inc.
Duplication or reproduction by any means without the express written consent of Studio Southwest Architects, Inc. is a violation of federal and International law. The information contained in this document is the intellectual property of Studio Southwest, Inc. and all rights thereto are Reserved. For exceptions refer to the Owner-Architect Agreement.
c
C U s e rs
\a m o n to y a
\D o c u m e n ts \D
P
O L V
A D
E R
A F
IR
E
S T
A T
IO
N
C G
S T
R U
C T v a m o n to y a c g
.r v t
/3
/2
:5 :5
A
M
POLVADERA FIRE
STATION
I-25 FRONTAGE ROAD NORTHBOUND
SOCORRO, COUNTY
NEW MEXICO
D062892017
6/30/2017
GHB
ADM
FOUNDATION PLAN
S-101
0000S-101.RVT
GENERAL SHEET NOTES
SHEET KEYNOTE
SCALE: 1/8" = 1'-0"A1
FOUNDATION PLAN
30° TYP
#6 REBAR
DOWEL
CENTERED
IN SLAB
PLAN
2' - 0"
4"
9' - 0" M
IN
9'
0" M
IN
#4 DWLS @ 18" OC
4 - 18" EMBED AHR BOLTS W/
STD WASHER AND DBL
NUTS. AHR BOLT DIAMETER
& LOCATION BY METAL BLDG
MFR
SEE SCHED FOR SIZE AND REINF
GRID
1/2" EXP MATL W/
CONT SEALANT
EXT SLAB SEE
ARCH
S E
E S
C H
E D
GRID
2" NON-SHRINK GROUT
1/2" EXP MATL W/
CONT SEALANT TYP
BASE PLATE AND
ANCHOR BOLTS PER
STEEL BLDG MFR
EQ EQ
SEE PLAN FOR SIZE AND REINF
3" C
LR
TO CONC EL
SEE CIVIL
COLUMN PER
STEEL BLDG MFR
M
IN
1'
3" C
LR
2 - #4 CONT T&B W/ #
3 STIRRUPS @ 32"
OC
1/2" EXP MATL W/
CONT SEALANT
SEE ARCH FOR
EXT SLAB
FIN FLR EL
SEE PLAN
1' - 0"
2'
3" C
LR
2 - #4 CONT T&B W/ #
3 STIRRUPS @ 32"
OC
FIN FLR EL
SEE PLAN
1' - 6"1' - 6"
1 ' - 0"
2 - #5 CONT
SLOPE
1' - 0"
DIAMOND PLATE DOWELS
@ 18"OC
1/2" EXP MATL W/
CONT SEALANT
ISSUE:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
DATE:
FILE:
SHEET TITLE
A
B
C
D
A
B
C
D
1 2 3 4 5
1 2 3 4 5
Architect Engineer
CONSULTANTS
STUDIO SOUTHWEST ARCHITECTS, INC.
2101 Mountain Rd. NW, Albuquerque, NM 87104
505.843.9639 Fax 505.843.9683
Web Site: www.studioswarch.com Email: mail@studioswarch.com
2013, Studio Southwest Architects, Inc.
Duplication or reproduction by any means without the express written consent of Studio Southwest Architects, Inc. is a violation of federal and International law. The information contained in this document is the intellectual property of Studio Southwest, Inc. and all rights thereto are Reserved. For exceptions refer to the Owner-Architect Agreement.
c
C U s e rs
\a m o n to y a
\D o c u m e n ts \D
P
O L V
A D
E R
A F
IR
E
S T
A T
IO
N
C G
S T
R U
C T v a m o n to y a c g
.r v t
/3
/2
:5 :5
A
M
POLVADERA FIRE
STATION
I-25 FRONTAGE ROAD NORTHBOUND
SOCORRO, COUNTY
NEW MEXICO
D062892017
6/30/2017
GHB
ADM
FOUNDATION
SECTIONS
S-301
0000S-301.RVT
SCALE: 3/4" = 1'-0"B3
REBAR DOWEL AT PERIMETER COL
SCALE: 3/4" = 1'-0"B4
FOUNDATION SECTION
SCALE: 3/4" = 1'-0"C4
EXTERIOR COLUMN SECTION
SCALE: 3/4" = 1'-0"A4
FOUNDATION SECTION
SCALE: 3/4" = 1'-0"C3
FOUNDATION SECTION
BASE PLATE SCHEDULE
MARK TYPE
A
SIZE
"T"x"A"x"B"
PL 3/4" x12"x1'-0"
BASE PLATE ANCHOR BOLTS
F1554
ANCHOR BOLTS
BP1 4 - 3/4" DIA x 9"
EQ EQ2" 2"
1' - 2"SCHED 'B'
E Q
E Q
2" 2"
1'
S C
H E
D 'A
TYPE 'A'
1'
S C
H E
D E
M B
E D
TYPICAL ANCHOR BOLT
DBL HEX NUTS
TOP OF
CONCRETE
STD WASHER W/
DBL HEX NUTS
1/8" x 1/4 DEPTH OF SLAB SAWCUT
FILL W/ EXTERIOR GRADE SEALANT
AT EXTERIOR CONDITIONS
CONTROL JOINT
CONSTRUCTION JOINT
DIAMOND PLATE DOWELS
@ 18"OC
DISCONTINUE ALTERNATE
REINF AT JOINT
1/
2" C
LR
1/ 2"
C
LR
Z BARS TO MATCH
SLAB REINF
FIN FLR EL
SEE PLAN
S E
E A
R C
H
REQUIRED LAP SPLICES
REINFORCEMENT TYPE
CON…
This is the start of the file's text. The full file is on GovTribe.