Clio High School Cafeteria Renovation – Construction Drawings
This file contains the complete construction drawing set for the Clio Area School District (CASD) High School Cafeteria Renovation project located at 1 Mustang Drive, Clio, Michigan 48420. The project, identified as 20116-1000, encompasses mechanical, electrical, and architectural renovation work for the first floor cafeteria and food service areas. The construction drawings were issued for bids on June 12, 2020, following a 50% Owner Review on March 20, 2020, and Quality Management Review on April 3, 2020. The scope includes demolition of existing systems, installation of new mechanical and electrical equipment, interior partition modifications, ceiling system replacement, flooring transitions, and new food service equipment installations. The drawings provide detailed specifications for partition types, door and frame schedules, room finish schedules, mechanical systems (including HVAC diffusers, plumbing connections, and fire protection), and electrical systems (including lighting fixtures, power distribution, fire alarm devices, and communications outlets).
The project adheres to the 2015 Michigan Building Code and 2015 Michigan Rehabilitation Code for Existing Buildings, with additional compliance required for mechanical, plumbing, electrical, and fire protection systems per state standards. Building classification is Use Group E (Educational) with Construction Type IIB, utilizing a partial fire suppression system in limited areas. The architectural documents indicate specific material selections including linoleum flooring (Forbo Marmoleum), ceramic tile, acoustical ceiling panels, gypsum board partitions, and hollow metal doors and frames. Electrical work includes LED lighting fixtures with 0-10V dimming controls, dual technology occupancy sensors, and a lighting control gateway system. The mechanical scope encompasses supply and return air diffusers, fire protection head installation, and plumbing connections for kitchen sinks and floor drains. Cost information is not provided in the drawing set; rather, the documents serve as the technical basis for contractor bidding and project execution.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADDENDUM NO.1.pdf | ||
| 20116-1000_Project Manual_Bids.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL
MR.0 Mechanical Reference Information
M1.1 First Floor Demolition Plan
M2.1 First Floor Mechanical Plan
ELECTRICAL
ER.0 Electrical Reference Information
E1.1 First Floor Demolition Plan
E2.1 First Floor Lighting Plan
E3.1 First Floor Power Plan
E6.1 Lighting Fixture and Panelboard Schedules
ARCHITECTURAL
AR.0 Architectural Reference Information
A1.1 First Floor Demolition Plan
A2.1 First Floor New Work Plan
A3.1 First Floor Reflected Ceiling Plan
A3.1a First Floor Reflected Ceiling Plan - Alternate 1
A9.1 Room Finish Schedule, Door Schedule and Details
A9.2 Partition Types, Interior Details and Interior Elevations
A10.1 First Floor - Finish Plan
F2.1 First Floor Furniture Plan
Cover
N O
R T
H
Project Number
Issue DateList of Drawings Code Information
Registration Seal
Date
Signature
Issued for
Date
Signature
Date
Signature
Site Map c 2020 , LLCI N TEG ETRA D SOLU T SNIO i D s architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
PROJECT SITE
VIENNA ST
N . M
IL
L
S T
N . S
AG
IN
A W
R D
TU
SC
O
LA
R D
MUSTANG D
R
BIM 360://CASD Clio High School Cafeteria Reno/20116 CASD HS Cafeteria Renovation-A20.rvt
6/12/2020 11:45:47 AM
20116-1000
Clio Area School District
1 Mustang Drive Clio, Michigan 48420
Clio High School Cafeteria Renovation
Building: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, 2015 Michigan Building Code, Incorporating the 2015 Edition of the International Building Code
Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, 2015 Michigan Rehabilitation Code for Existing Buildings, Incorporating the 2015 Edition of the International Existing Building Code
Michigan Department of Licensing and Regulatory Affairs, Bureau of Fire Services, 2016 Fire Safety Rules for Schools, Colleges and Universities, Incorporating the 2012 Edition of the NFPA 101 Life Safety Code
Barrier Free: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, 2015 Michigan Building Code, Incorporating the 2015 Edition of the International Building Code
Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, 2009 ICC A117.1 - Accessible and Usable Buildings and Facilities
Mechanical: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, Mechanical Division, 2015 Michigan Mechanical Code, Incorporating the 2015 Edition of the International Mechanical Code
Plumbing: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, Plumbing Division, 2015 Michigan Plumbing Code, Incorporating the 2015 Edition of the International Plumbing Code
Fire Protection: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, 2015 Michigan Building Code, Incorporating the 2013 Edition of NFPA 13 - Installation of Sprinkler Systems
Electrical: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, Electrical Division, 2017 Michigan Electrical Code, Incorporating the 2017 Edition of the National Electrical Code
Fire Alarm: Michigan Department of Licensing and Regulatory Affairs, Bureau of Construction Codes, Electrical Division, Incorporating the 2013 Edition of NFPA 72 - National Fire Alarm and Signaling Code
Building Information Use Group Classification: E (Educational) Construction Type: IIB - MBC
II(000) - NFPA 2020
Fire Suppression System: Partial (Limited Areas) Building Height: Unchanged Area Calculations: Unchanged Occupant Loads: Unchanged Exit Capacity: Unchanged
50% Owner Review 03-20-2020
Quality Management Review 04-03-2020
Bids 06-12-2020
S T
D
M A
X B
F
M A
X B
F
7"
M
IN
M A
X B
F
M
A X
M
A X
M
A X
U
O N
M
IN
0"
M
IN 8
2"
M A
X
12" MIN TO
M A
X
M
IN
M A
X
M A
X
17"
17"
4"
" 4"
BF
30" MIN
/2
M
18"
60" CLEAR
30" MIN
S T
D
M A
36"
4"
60" CLEAR
BF
36" MIN
15"
/2
M A
X
M
36" CLEAR
M
IN
M A
X
BF
36" CLEAR
T O
W E
L D
IS
P
E N
S E
R W
A S
E
R
C
E P
T A
C
LE
W A
S T
E R
E C
E P
T A
C
LE
S A
N
IT
A R
Y N
A P
K
IN
D
IS
P E
N S
S
H E
LF
T O
W E
L D
IS
P
E N
S E
R
F
IR
E E
X T
IN
G
U
IS
H E
R C
A B
IN
E
T
W A
LL
M
T D
F
IR
E E
X T
IN
G
U
IS
H
W
LL
O
R E
M E
R G
E N
C Y
T E
LE
P
H O
N E
T O
W E
L B
A R
F
IR
E H
O S
E O
R V
A
LV
E C
A B
IN
E
T
H O
O K
S T
R
IP
S H
E
LF
W / M
O P
A N
D R
O O
M
H
LD
E
R S
A N
D H
O O
K S
E W
C O
R D
R
IN
K
IN
G F
O U
N T
A
IN
(S P
O U
T O
U T
LE
T
F U
LL
H
E
IG
H T
M
IR
R
(1 8" x6 0"
M
IN
C H
A
LK
B O
A R
D M
A R
K E
R B
O A
R D
O R
T A
C K
B O
A R
D
BF WATER CLOSET
SIDE WALL
STD WATER CLOSET
SIDE WALL
F
LO
O R
D E
S
IG
N A
T
IO
N B
O T
H J
A M
B S
E
LE
V A
T O
R L
A N
D
IN
G C
A
LL
B U
T T
O N
S
B
LD
G E
N T
R A
N C
E S
Y M
B O
L
F
C
C E
S S
IB
IL
IT
Y
E X
T E
R
IO
R P
O S
T M
T D
S
IG
N
E X
T E
R
IO
R W
A
LL
M T
D S
IG
N
H A
LL
L
A N
T E
R N
IN
T
E R
IO
R
W A
LL
M
T D
S
IG
N
B F
A U
T O
D O
O R
A C
T U
A T
B
U T
T O
N
BF WATER CLOSET
BACK WALL
MOUNTING HEIGHTS
MOUNTING HEIGHTS SHOWN ARE BASED UPON
RECOGNIZED DESIGN STANDARDS AND/OR BARRIER
FREE CODE REQUIREMENTS. IT IS INTENDED THAT LIKE
DEVICES ALL BE MOUNTED AT THE SAME HEIGHT
THROUGHOUT THE ENTIRE PROJECT. RECESSED
DEVICES IN MASONRY WALLS MAY DICTATE A DEVIATION
(± 2") FROM THESE HEIGHTS (WHEN PERMITTED BY
CODE) SO AS TO ALLOW THE BOTTOM OR THE TOP OF
THE DEVICE RECESS TO ALIGN WITH MASONRY
COURSING. COORDINATE THESE DEVIATIONS WITH THE
ARCHITECT'S/OWNER'S REPRESENTATIVE.
MOUNTING HEIGHTS ARE TYPICAL UNLESS OTHERWISE
NOTED ON DRAWINGS.
H
A N
LE
H
A N
D
LE
MASONRY COURSING
ELEC DEVICE
STD & BF LAVATORY
S O
A P
D
IS
P E
N S
E R
D
IA
P E
R C
H A
N G
IN
G
S T
A T
IO
N
S E
A T
C O
V E
R D
IS
P
E N
S E
R
B F
F R
A M
E D
M
IR
R
(1 8" x
M
IN
H A
N D
D R
Y E
R
H A
IR
D
R Y
E R
H A
N D
S A
N
IT
IZ
E
R
BF WATER CLOSET
BACK WALL
BF ROLL-IN SHOWER WITH BENCH BACK WALL / CONTROL WALL
CLEAR
M A
X B
F
URINAL AMBULATORY STALL
BACK WALL
AMBULATORY STALL SIDE WALL ALT BF ROLL-IN SHOWER BENCH SIDE WALL / CONTROL WALL BF TRANSFER SHOWER SIDE WALL / CONTROL WALL
S
IN
K H
E
IG
H T
T O
P O
F T
O
IL
E T
S E
A T
G R
A B
B A
R
T Y
P E
P
IE
C
E
F
LU
S H
V A
LV
E
H A
N D
LE
T O
P O
F T
O
IL
E T
S E
A T
F
LU
S H
V A
LV
E
H A
N D
LE
G R
A B
B A
R
T Y
P E
G R
A B
B A
R
T Y
P E
G R
A B
B A
R
T Y
P E
B F
T O
IL
E
T P
A P
E R
H O
LD
E
R
JU
M
B O
T O
IL
E
T P
A P
E R
H O
LD
E
R
B F
S A
N
IT
A R
Y N
A P
K
IN
D
IS
P O
S A
L
S T
D T
O
IL
E T
P A
P E
R H
O
LD
E R
JU
M
B O
T O
IL
E
T P
A P
E R
H O
LD
E
R
S T
D S
A N
IT
A
R Y
N A
P K
IN
D
IS
P
O S
A L
G R
A B
B A
R
T Y
P E
W A
T E
R C
O N
T R
O L
/ H A
N D
S H
O W
E R
G R
A B
B A
R
T Y
P E
2)
S H
O W
E R
B E
N C
H
W A
T E
R C
O N
T R
O L
F
IX
E D
S H
O W
E R
H E
A D
S H
O W
E R
C U
R T
A
IN
R O
D
F
LU
S H
V A
LV
E
H A
N D
LE
R
IM
H E
IG
H
T
U R
IN
A
L S
C R
E E
N
P A
R T
IT
IO
N H
E
IG
H T
G R
A B
B A
R
T Y
P E
T O
P O
F T
O
IL
E T
S E
A T
F
LU
S H
V A
LV
E
H A
N D
LE
G R
A B
B A
R
T Y
P E
G R
A B
B A
R
T Y
P E
B F
T O
IL
E
T P
A P
E R
H O
LD
E
R
JU
M
B O
T O
IL
E
T P
A P
E R
H O
LD
E
R
B F
S A
N
IT
A R
Y N
A P
K
IN
D
IS
P O
S A
L
S H
O W
E R
C U
R T
A
IN
R O
D
G R
A B
B A
R
T Y
P E
F
IX
E D
S H
O W
E R
H E
A D
G R
A B
B A
R
T Y
P E
W A
T E
R C
O N
T R
O L
W A
T E
R C
O N
T R
O L
/ H A
N D
S H
O W
E R
S H
O W
E R
C U
R T
A
IN
R O
D
S H
O W
E R
B E
N C
H
G R
A B
B A
R
T Y
P E
W A
T E
R C
O N
T R
O L
/ H A
N D
S H
O W
E R
W A
T E
R C
O N
T R
O L
G R
A B
B A
R
T Y
P E
G R
A B
B A
R
T Y
P E
F
IX
E D
S H
O W
E R
H E
A D
THIS PROJECT MAY NOT UTILIZE ALL THE
SYMBOLS, MATERIALS, ABBREVIATIONS AND
STANDARD INFORMATION SHOWN ON THIS SHEET
17"-19"
40"
42" 12"
7"
6" MAX
6" MAX
6" MAX
30"
18"72
IN
M A
X B
B F
6" MAX 36"
5" MAX
6" MAX 36"
42" 12"
40"
7" 7"
6" MAX
42"
M
IN
6" MAX
C
LE
A R
B F
S T
D
S T
D
M E
N
S
T D
W
O M
E N
SEE PLAN
C L C L
SECTION OR DETAIL
DETAIL SCALE
SECTION OR DETAIL IDENTIFICATION
A2.1
DRAWING WHERE DETAIL
IS REFERENCED OR CUT
SECTION OR DETAIL TITLE
SECTION OR DETAIL IDENTIFICATION
A9.1
DRAWING WHERE SECTION OR DETAIL
IS DRAWN
SECTION OR DETAIL LOCATOR
ELEVATION IDENTIFICATION
DRAWING WHERE ELEVATION
IS DRAWN
3 A8.1
SYMBOL LEGEND
INTERIOR ELEVATION SYMBOL
EXTERIOR ELEVATION SYMBOL
ELEVATION IDENTIFICATION
DRAWING WHERE ELEVATION
IS DRAWN
MATERIAL KEYNOTE
PROJECT MANUAL SECTION
IDENTIFICATION
08 1113
A101
ROOM NAME
ROOM
FLOOR
BUILDING OR UNIT (IF ANY)
ROOM NAME AND NUMBER
PARTITION TYPE
0B3
PARTITION TYPE IDENTIFICATION
(REFER TO FLOOR PLAN)
DOOR NUMBER
A101
ROOM
FLOOR
BUILDING OR UNIT (IF ANY)
NEW DOOREXISTING DOOR
A
DRAWING WHERE BUILDING SECTION IS DRAWN
A4.2
A4.2
BUILDING SECTION LOCATOR
LARGE SCALE PLAN OR DETAIL
PLAN OR DETAIL
IDENTIFICATION
DRAWING WHERE
PLAN OR DETAIL
IS DRAWN
COLUMN DESIGNATION/CENTERLINE
EXISTING
NEW
A6.1
BUILDING SECTION IDENTIFICATION
DRAWING WHERE WALL SECTION IS DRAWN
A5.1
EXTERIOR WALL SECTION LOCATOR
WALL SECTION IDENTIFICATION
A4.1
MATERIAL LEGEND
SOIL
GRANULAR FILL
GRAVEL
CONCRETE
CONCRETE MASONRY UNIT
BRICK
GLAZED CMU
STRUCTURAL GLAZED
FACING TILE
MARBLE
METALS
FINISH WOOD
PLYWOOD
RIGID INSULATION
CAVITY WALL
INSULATION
ROOF INSULATION
PREMOLDED EXPANSION
JOINT OR COMPRESSIBLE
FILLER STRIP
GLASS OR PLASTIC
GLAZING
PLASTER OR GYPSUM
BOARD
CERAMIC OR QUARRY TILE
ACOUSTICAL PANEL OR
ACOUSTICAL TILE
STONE
BATT INSULATION
TERRAZZO
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
As Noted
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
AR.0
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
20116-1000
1 Mustang Drive Clio, Michigan 48420
Architectural Reference Information
Clio High School Cafeteria Renovation
CUH CABINET UNIT HEATER
CSK COUNTERSINK (SUNK) FH FIRE HYDRANT
CT CERAMIC TILE FIN FLR FINISH FLOOR JST JOIST
CSWK CASEWORK FEC FIRE EXTINGUISHER CABINET JT JOINT
T TEE
COORD COORDINATE FEB FIRE EXTINGUISHER AND BRACKET JC JANITOR CLOSET
CORR CORRUGATED FE FIRE EXTINGUISHER RFG ROOFING
PLATE
COR CORRIDOR FDTN FOUNDATION J REV REVISED, REVISION TYP TYPICAL
CONV CONVERTOR FDC FIRE DEPARTMENT CONNECTION RESIL RESILENT TOW TOP OF WALL
# NUMBER OR POUND
CONTR CONTRACTOR FD FLOOR DRAIN INT INTERIOR NTS NOT TO SCALE REQD REQUIRED TV TELEVISION
CONT CONTINUE, CONTINUOUS FACP FIRE ALARM CONTROL PANEL IR IMPACT RESISTANT NRC NOICE REDUCTION COEFFICIENT REINFORCING TRANS TRANSOM
" INCH, INCHES
CONSTR CONSTRUCTION FAC FACTORY INSUL INSULATE, INSULATION NOM NOMINAL REINF REINFORCE, REINFORCEMENT, TOS TOP OF STEEL
CONN CONNECT, CONNECTION IN INCH, INCHES NO NUMBER REFRIG REFRIGERATOR TOM TOP OF MASONRY
' FEET, FOOT
CONF CONFERENCE F INFO INFORMATION NIC NOT IN CONTRACT REFL REFLECTED, RELECTIVE TKSP TACK STRIP
CONC CONCRETE INCL INCLUDE, INCLUDING REF REFER, REFERENCE THK THICK, THICKNESS
Ø DIAMETER
COMPO COMPOSITION EXT EXTERIOR IE INVERT ELEVATION N RC RAIN CONDUCTOR T/F TOP OF FOOTING
COMP COMPACTED EXP BT EXPANSION BOLT ID INSIDE DIAMETER RAD RADIUS TER TERRAZZO
° DEGREE OR DEGREES
COL COLUMN EXP EXPANDED, EXPANSION MULL MULLION R RISER TEMP GL TEMPERED GLASS
CO CLEAN OUT EXIST EXISTING I MTD MOUNTED TEL TELEPHONE [ CHANNEL
CMU CONCRETE MASONRY UNIT EWC ELECTRICAL WATER COOLER MRT MARBLE THRESHOLD R T/C TOP OF COVER OR CURB
CLG CEILING EW EACH WAY HR HOUR MO MASONRY OPENING TKBD TACKBOARD
CENTERLINE
CJ CONTROL OR CONSTRUCTION JOINT EQUIP EQUIPMENT HP HIGH POINT MLDG MOULDING QT QUARRY TILE T & G TONGUE AND GROOVE
CHKD PL CHECKERED PLATE EQ EQUAL HORIZB HORIZONTAL BLINDS MKBD MARKERBOARD T & B TOP AND BOTTOM
X BY
CHBD CHALKBOARD EP ELECTRICAL PANEL HORIZ HORIZONTAL, HORIZONTALLY MISC MISCELLANEOUS Q T TREAD
CG CORNER GUARD ENTR ENTRANCE, ENTRY HM HOLLOW METAL MIN MINIMUM
L ANGLE
CCT CUBICLE CURTAIN TRACK ENCL ENCLOSURE HDWE HARDWARE MH MANHOLE PVW PROTECTIVE VINYL WALL COVERING T CBB CEMENT BACKER BOARD ELEV ELEVATOR HDWD HARDWOOD MFR MANUFACTURER PVF POLYVINYL FLUORIDE COATING (KYNAR)
CB CATCH BASIN ELEC ELECTRIC, ELECTRICAL HC HOLLOW CORE MEZZ MEZZANINE PVC POLYVINYLCHLORIDE SYMM SYMMETRICAL
CAB CABINET EL ELEVATION HB HOSE BIBB MT METAL THRESHOLD PTN PARTITION SYM SYMBOL WWF WELDED WIRE FABRIC
EJ EXPANSION JOINT H HIGH, HEIGHT MET METAL OR METALLIC PT PAINT SUSP SUSPEND, SUSPENSION WSTPG WEATHERSTRIPPINGC EIFS EXTERIOR INSULATION FINISH SYSTEM MECH MECHANICAL PSI POUNDS PER SQUARE INCH SURF SURFACE WSCT WATERSTOP
EF EXHAUST FAN H MDS METAL DIVING STRIP PSF POUNDS PER SQUARE FOOT STN STAIN WP WORKING POINT
B/D BOTTOM OF DECK EA EACH MCC MULTI COLOR COATING PS PROJECTION SCREEN ST STL STAINLESS STEEL WPF WEATHERPROOF
BUR BUILT UP ROOFING SYSTEM GYP BD GYPSUM BOARD MAX MAXIMUM PREFAB PREFABRICATION STRUCT STRUCTURAL WP WATERPROOF
BSMT BASEMENT E GRL GRILLE MATL MATERIAL PR PAIR STL STEEL W/O WITHOUT
BRKT BRACKET GRG GLASS REINFORCED GYPSUM MAINT MAINTENANCE PORC PORCELAIN STD STANDARD WO WINDOW OPENING
BRG BEARING DWR DRAWER GR GRADE POC POROUS STC SOUND TRANSMISSION CLASS WM WIRE MESH
BOT BOTTOM DWL DOWEL GL GLASS M POL POLISH, POLISHED STAG STAGGERED WD WOOD
BN BULLNOSE DT DRAIN TILE GI GALVANIZED IRON PLYWD PLYWOOD SS SERVICE SINK W/ WITH
BLKG BLOCKING DWG DRAWING GRFG GLASS FIBER REINFORCED GYPSUM LT WT LIGHT WEIGHT P LAM PLASTIC LAMINATED SQ SQUARE WSCT WAINSCOTT
BLDG BUILDING DR DOOR GRFC GLASS FIBER REINFORCED CONCRETE LPRF LIGHT PROOF PLAS PLASTER SPEC SPECIFICATION WBR WALL BUMPER RAIL
BF BARRIER FREE DR OPNG DOOR OPENING GALV GALVANIZED LP LOW POINT PLBG PLUMBING SIM SIMILAR W WIDE, WIDTH
BEV BEVEL, BEVELED DN DOWN GA GAGE, GAUGE LO LOUVER OPENING PRKG PARKING SH/P SHELF AND POLE
BD BOARD DMT DEMOUNTABLE LLV LONG LEG VERTICAL PERIM PERIMETER SGFT STRUCTURAL GLAZED FACING TILE W DMPF DAMPPROOFING SYSTEM G LLH LONG LEG HORIZONTAL PERF PERFORATED SF SQUARE FEET (FOOT)B DEFS DIRECT APPLIED EXT FINISH SYSTEM LKR LOCKER PORC EN PORCELAIN ENAMEL SECT SECTION VWC VINYL WALL COVERING
DIR DIRECTORY FWC FABRIC WALL COVERING LHR LEFT HAND REVERSE PC PIECE SCR SHOWER CURTAIN ROD VTR VENT THRU ROOF
AUTO AUTOMATIC DIM DIMENSION FVC FIRE VALVE CABINET LH LEFT HAND P/C PRECAST SCHED SCHEDULE VRS VINYL REDUCER STRIP
ARCH ARCHITECT, ARCHITECTURAL DIFF DIFFUSER FTR FIN TUBE RADIATION LF LINEAR FOOT PBD PARTICLEBOARD SC SOLID CORE VR VAPOR RETARDER
APPROX APPROXIMATELY DIAG DIAGONAL FTG FOOTING LBS POUNDS PA PUBLIC ADDRESS VIT VITREOUS
ACS PNL ACCESS PANEL DIA DIAMETER FT FEET, FOOT LBL LABEL S VIF VERIFY IN FIELD
ANOD ANODIZED DF DRINKING FOUNTAIN FRP FIBERGLASS REINFORCED PANEL LAV LAVATORY P VERTB VERTICAL BLINDS
ALUM ALUMINUM DET DETAIL FRGM FIRE RATED GLAZING MARKINGS LAM LAMINATE, LAMINATED RT RUBBER TILE VERT VERTICAL, VERTICALLY
ALT ALTERNATE DEPT DEPARTMENT FR FRAME LAB LABORATORY OZ OUNCE RSD ROLLER SHADE VCT VINYL COMPOSITION TILE
AFF ABOVE FINISH FLOOR DEPR DEPRESSED FPRFG FIREPROOFING L LONG, LENGTH ORN ORNAMENTAL RS ROOF SUMP
ADJ ADJACENT, ADJUSTABLE DEMO DEMOLISH, DEMOLITION FLR FLOOR OPP HD OPPOSITE HAND RR RAILROAD V ACU AIR CONDITIONING UNIT DT DR DUTCH DOOR FLASH FLASHING L OPNG OPENING ROW RIGHT OF WAY
ACOUS ACOUSTIC, ACOUSTICAL DWTR DUMBWAITER FIN FINISH, FINISHED O/H OVERHEAD RO ROUGH OPENING UON UNLESS OTHERWISE NOTED
ABRSV ABRASIVE DBL DOUBLE FHR FIRE HOSE RACK KIT KITCHEN OD OUTISDE DIAMETER RHR RIGHT HAND REVERSE UL UNDERWRITERS LABORATORIES,INC.
AB ABUSE RESISTANT D DEPTH FHC FIRE HOSE CABINET KD KNOCK DOWN OC ON CENTER RH RIGHT HAND UC UNDERCUT
A D F (CONT) K O R (CONT) U
ABBREVIATIONS
50% Owner Review 03-20-2020
DEMOLITION PLAN
A. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED TO
WHAT IS SHOWN ON THE DEMOLITION PLAN. THE INTENT IS TO
REMOVE ALL MECHANICAL, ELECTRICAL, AND ARCHITECTURAL ITEMS
AS REQUIRED TO FACILITATE NEW CONSTRUCTION.
B. CONTRACTOR SHALL PROVIDE TEMPORARY DUSTPROOF PARTITIONS
WITH DOORS AT LOCATIONS INDICATED AND/OR AS REQUIRED TO
ADEQUATELY SEPARATE OCCUPIED AREAS FROM CONSTRUCTION
HAZARDS, NOISE AND/OR DUST. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION. COORDINATE ALL LOCATIONS WITH
ARCHITECT'S/OWNER'S REPRESENTATIVE.
C. CONTRACTOR SHALL PROVIDE DUST MATS AT ALL CONSTRUCTION
AREA ENTRANCES AND EXIT LOCATIONS. COORDINATE ALL
LOCATION'S WITH ARCHITECT'S/OWNER'S REPRESENTATIVES.
D. CONTRACTOR SHALL CONTINUOUSLY MAINTAIN ALL MEANS OF
EGRESS AND ALL FIRE PROTECTION FEATURES FOR PORTIONS OF
THE BUILDING THAT REMAIN OCCUPIED DURING CONSTRUCTION.
E. COORDINATE SCOPE AND EXTENT OF DEMOLITION WITH NEW WORK
PLANS AND DETAILS.
F. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS
FOR ADDITIONAL INFORMATION.
G. IDS HAS NOT IDENTIFIED ASBESTOS CONTAINING MATERIAL (ACM) ON
THE DEMOLITION DRAWINGS. CONTRACTORS SHOULD VERIFY ACM
PRESENT WITH THE UPDATED ACM REPORT PROVIDED BY CLIO AREA
SCHOOL DISTRICT.
GENERAL NOTES
LEGEND
DEMOLITION PLAN
NOTE: NOT ALL SYMBOLS MAY BE USED
EXISTING TO REMAIN
EXISTING CEILING TO BE REMOVED
AS NOTED BY KEYNOTE
EXISTING FLOOR/FINISH TO BE REMOVED
AS NOTED BY KEYNOTE
EXISTING TO BE REMOVED
SAWCUT AND REMOVE PORTION OF CONC SLAB
AS NOTED BY KEYNOTE
X
X
X
D1
D2
D5
D3
D3
D2
D4
D4
D7
D8
D9
D10
D11
D11
D12 D13
SERVING
SERVING
CAFETERIA
STORAGE
JANITOR
CLOSET
STORAGE
JANITOR
CLOSET
100A
WOMEN'S
TOILET
ROOM
PLUMBING
CHASE
MEN'S
TOILET
ROOM
STORAGE
STORAGE
OFFICE
DISHWASH
CORRIDOR
CORRIDOR
VESTIBULE
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
A1.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
1/4" = 1' - 0"
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor Demolition Plan
Clio High School Cafeteria Renovation
LEGEND SYMBOL INDICATOR
NOTE: NOT ALL KEYNOTES MAY BE USED
SHADED ITEMS HAVE BEEN REVISED FROM PREVIOUS
DEMOLITION PLAN
KEYNOTES
D1 REMOVE GYPSUM BOARD / METAL STUD PARTITION. COORDINATE WITH
NEW WORK PLANS
D2 REMOVE VCT FLOORING, BASE AND ADHESIVE DOWN TO STRUCTURAL
SLAB
D3 REMOVE PLASTER / METAL LATH CEILING AND SUSPENSION SYSTEM
D4 REMOVE ACOUSTICAL CEILING PANELS, GRID AND SUSPENSION
SYSTEM
D5 REMOVE DOOR, FRAME AND SILL IN ITS ENTIRETY
D7 REMOVE BASE CABINETS, COUNTERTOP, WALL PEGBOARD, SHELVING
AND STANDARDS IN THEIR ENTIRETY
D8 REMOVE OVERHEAD COUNTER SHUTTER, COUNTER AND STORAGE IN
THEIR ENTIRETY
D9 REMOVE WALL-MOUNTED TV SUPPORT BRACKET
D10 REMOVE 4" CMU KNEE WALL (±2'-8" HIGH, VIF)
D11 REMOVE WOOD CLEAT WITH HOOKS
D12 REMOVE WHITEBOARD. RETURN TO OWNER
D13 REMOVE BASE CABINETS, COUNTERTOP, SINK AND CHASE WALL IN
THEIR ENTIRETY
50% Owner Review 03-20-2020
LEGEND
NEW WORK PLAN
NOTE: NOT ALL SYMBOLS MAY BE USED
SHALL COMPLY WITH BARRIER FREE REQUIREMENTS
PARTITION TYPE - REFER TO PARTITION DETAILS
DRAWING A9.2
EXISTING CONSTRUCTION
NEW CONSTRUCTION
XXX
CASEWORK/ MILLWORK TAG
CORNER GUARD
XXXX
NEW WORK PLAN
A. REFER TO DRAWING A9.1 FOR DOOR SCHEDULE AND COLORS.
B. REFER TO DRAWING A9.1 FOR FINISH SCHEDULE AND COLORS.
C. REFER TO LIFE SAFETY PLANS FOR PARTITION RATINGS.
D. PARTIAL WALL POCHEING IS SHOWN THROUGHOUT THIS PLAN AND
THE TERMINATION OF SAME SHALL NOT BE CONSTRUED TO
REPRESENT A CHANGE IN WALL MATERIAL. VERIFY WALL MATERIALS
WITH PARTITION TYPES AND SCHEDULES.
E. PATCH AND/OR REPAIR ALL EXISTING FLOOR, WALL AND OR CEILING
FINISHES AS REQUIRED TO MATCH EXISTING OR TO ACCEPT NEW
FINISHES AS SCHEDULED AT ALL AREAS AFFECTED BY THE
DEMOLITION WORK. REFER TO MECHANICAL AND ELECTRICAL
DRAWINGS FOR ADDITIONAL SCOPE OF WORK.
F. INFILL ALL OPENINGS IN EXISTING WALLS ABOVE CEILINGS THAT ARE
THE RESULT OF MECHANICAL OR ELECTRICAL DEMOLITION.
OPENINGS IN MASONRY WALLS SHALL BE FILLED WITH MASONRY OF
SIMILAR TYPES AND THICKNESS AS EXISTING. OPENINGS IN OTHER
TYPES OF WALL CONSTRUCTION SHALL MATCH EXISTING
MATERIALS, FINISHES AND WALL THICKNESS. REFER TO
MECHANICAL AND ELECTRICAL DRAWINGS FOR SCOPE OF WORK.
G. PROVIDE POSITIVE SLOPE TO ALL FLOOR DRAINS WHILE KEEPING
FLOOR LEVEL AT WALL BASE.
H. COORDINATE SIZE AND LOCATION OF ALL ACCESS DOORS WITH
TRADES REQUIRING SAME. QUANTITIES SHOWN DO NOT
NECESSARILY REPRESENT ALL ACCESS DOORS REQUIRED FOR
ACCESSIBILITY.
GENERAL NOTES
2b
102a
FOOD
SERVICE
AREA
JANITORS
CLOSET
SERVING
SERVING
CAFETERIA
JANITOR
CLOSET
JANITOR
CLOSET
100A
WOMEN'S
TOILET
ROOM
PLUMBING
CHASE
MEN'S
TOILET
ROOM
STORAGE
STORAGE
OFFICE
DISHWASH
VESTIBULE
'-4
H
IG
H
V
IF
3/ 8"
V
IF
1B6
7'
R O
6'
3'
8 " C
M U
R
E F
T O
IN
T
E R
IO
R
E
LE
V A
T
IO
N
1'
6'
C L
A1
A1
A2
A2
A9.23
A9.2
0a
A9.2
0B1
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
A2.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
1/4" = 1' - 0"
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor New Work Plan
Clio High School Cafeteria Renovation
LEGEND SYMBOL INDICATOR
NOTE: NOT ALL KEYNOTES MAY BE USED
SHADED ITEMS HAVE BEEN REVISED FROM PREVIOUS
NEW WORK FLOOR PLAN
KEYNOTES
A1 TOOTH-IN 04 2000 8" CMU (MIN 8")
A2 PATCH EXIST CMU AT AREA OF REMOVED WALL. MATCH EXISTING
FINISH
50% Owner Review 03-20-2020
F F F
F F F
L L L
L L L
L L L
L
S S S
S S S
S
L
L
F
F F
F
L
REFLECTED CEILING PLAN
A. CEILING HEIGHT 9'-0" AFF UNLESS OTHERWISE NOTED.
B. ACOUSTICAL CEILING PANELS AND/OR TILES SHALL BE CENTERED
WITHIN THE ROOM OR BORDER UNLESS OTHERWISE NOTED.
C. REFER TO FLOOR PLANS FOR PARTITION TYPE DESIGNATION.
D. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER CEILING
SPACE EQUIPMENT SUPPORTING DEVICES.
E. UNLESS OTHERWISE NOTED LOCATION OF ITEMS SHOWN IN AREAS
WITHOUT FINISH CEILINGS IS APPROXIMATE. COORDINATE EXACT
LOCATION BETWEEN TRADES.
F. COORDINATE SIZE AND LOCATION OF ALL ACCESS DOORS WITH
TRADES REQUIRING SAME. QUANTITIES SHOWN DO NOT
NECESSARILY REPRESENT ALL ACCESS DOORS REQUIRED FOR
ACCESSIBILITY.
GENERAL NOTES
RECESSED DOWNLIGHT
RECESSED LINEAR LIGHT FIXTURE
PENDANT LIGHT FIXTURE
PENDANT LINEAR LIGHT FIXTURE
LIGHT FIXTURE
LINEAR RETURN DIFFUSER
LINEAR SUPPLY DIFFUSER
RETURN AIR REGISTER/GRILLS
EXHAUST AIR DIFFUSER
LIGHTING OCCUPANCY SENSOR
FIRE ALARM DEVICE
SPEAKER
SPRINKLER HEAD
LAY-IN CEILING
GYPSUM BOARD CEILING
LEGEND
REFLECTED CEILING PLAN
NOTE: NOT ALL SYMBOLS MAY BE USED
INDUSTRIAL LIGHT FIXTURE
MICROPHONE
ACOUSTIC METAL DECK
PHOTOELECTRIC SWITCH
EXIT SIGN
ACCESS PANEL (24X24 UON)
WIRELESS ACCESS POINT
RADIANT CEILING PANEL
EXISTING LAY-IN CEILING
SUPPLY AIR REGISTER/GRILLS
11' - 0"
10' - 0"
FOOD
SERVICE
AREA
JANITORS
CLOSET
SERVING
SERVING
CAFETERIA
JANITOR
CLOSET
JANITOR
CLOSET
100A
WOMEN'S
TOILET
ROOM
PLUMBING
CHASE
MEN'S
TOILET
ROOM
STORAGE
STORAGE
OFFICE
DISHWASH
VESTIBULE
A3.1a
ALT 1
DEMO
ALT 1
NEW
WORK
A3.1a
C1
EQ EQ
6'
3'
R 18' - 4"
EXIST 1-HR RATED
PARTITION (ASSUMED)
C L
O F
LG
G
ID
A
LU
F
T E
R A
N
Y P
B D
P
IE
R
LEGEND
LIFE SAFETY
NOTE: NOT ALL SYMBOLS MAY BE USED
1-HR FIRE-RATED PARTITION
2-HR FIRE-RATED PARTITION
EXIT
000/000
EXIT CAPACITY / TABULAR OCCUPANT LOAD
SMOKE TIGHT PARTITION
1 HR FIRE RATED CEILING CONSTRUCTION
3-HR FIRE-RATED PARTITION
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
A3.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
1/4" = 1' - 0"
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor Reflected Ceiling Plan
Clio High School Cafeteria Renovation
LEGEND SYMBOL INDICATOR
NOTE: NOT ALL KEYNOTES MAY BE USED
SHADED ITEMS HAVE BEEN REVISED FROM PREVIOUS
REFLECTED CEILING PLAN
KEYNOTES
C1 POCHE INDICATES EXTENT OF 09 5113 ACOUSTICAL LAY-IN CEILING
PANELS AC-02
C2 09 2900 5/8" GYPSUM BOARD ON 09 2216 GRID SUSPENSION
SYSTEM. 09 9600 PAINT (BLACK)
C3 PATCH/REPAIR GYP BD AT PREVIOUS LOCATION OF ALUMINUM
RAFTER BEARING 50% Owner Review 03-20-2020
L
L
F
L
REFLECTED CEILING PLAN
A. CEILING HEIGHT 9'-0" AFF UNLESS OTHERWISE NOTED.
B. ACOUSTICAL CEILING PANELS AND/OR TILES SHALL BE CENTERED
WITHIN THE ROOM OR BORDER UNLESS OTHERWISE NOTED.
C. REFER TO FLOOR PLANS FOR PARTITION TYPE DESIGNATION.
D. COORDINATE CEILING SUSPENSION SYSTEMS WITH OTHER CEILING
SPACE EQUIPMENT SUPPORTING DEVICES.
E. UNLESS OTHERWISE NOTED LOCATION OF ITEMS SHOWN IN AREAS
WITHOUT FINISH CEILINGS IS APPROXIMATE. COORDINATE EXACT
LOCATION BETWEEN TRADES.
F. COORDINATE SIZE AND LOCATION OF ALL ACCESS DOORS WITH
TRADES REQUIRING SAME. QUANTITIES SHOWN DO NOT
NECESSARILY REPRESENT ALL ACCESS DOORS REQUIRED FOR
ACCESSIBILITY.
GENERAL NOTES
RECESSED DOWNLIGHT
RECESSED LINEAR LIGHT FIXTURE
PENDANT LIGHT FIXTURE
PENDANT LINEAR LIGHT FIXTURE
LIGHT FIXTURE
LINEAR RETURN DIFFUSER
LINEAR SUPPLY DIFFUSER
RETURN AIR REGISTER/GRILLS
EXHAUST AIR DIFFUSER
LIGHTING OCCUPANCY SENSOR
FIRE ALARM DEVICE
SPEAKER
SPRINKLER HEAD
LAY-IN CEILING
GYPSUM BOARD CEILING
LEGEND
REFLECTED CEILING PLAN
NOTE: NOT ALL SYMBOLS MAY BE USED
INDUSTRIAL LIGHT FIXTURE
MICROPHONE
ACOUSTIC METAL DECK
PHOTOELECTRIC SWITCH
EXIT SIGN
ACCESS PANEL (24X24 UON)
WIRELESS ACCESS POINT
RADIANT CEILING PANEL
EXISTING LAY-IN CEILING
SUPPLY AIR REGISTER/GRILLS
DASHED LINE REPRESENTS LINE OF
SOFFIT DROP IN ACOUSTIC PLASTER
CEILING ABOVE EXIST LAY-IN. REF TO
TAG FOR EXIST ELEVATIONS
REMOVE AND SALVAGE
2X8 ALUMINUM RAFTERS
AND MOUNTING
HARDWARE. REF TO
NEW WORK FOR
REINSTALLATION (TYP 5)
14'-0" 12'-0"
LINE OF EXIST
STRUCTURAL
STEEL JOIST
19' - 0"
REMOVE PORTION
ACOUSTIC PLASTER
CEILING, LIGHT FIXTURES,
ETC. WITHIN DASHED
AREA AS INDICATED
SERVING
105 101
CAFETERIA
8' - 8 1/2" ± VIF 9' - 4" ± VIF
12' - 2"
11' - 0"
SERVING
105 101
CAFETERIA
A9.2
E P
O X
Y P
A
IN
T E
X
IS
T C
M U
T O
M A
T C
H E
X
IS
T U
P T
O
2'
A F
F
/4
X
R
O 6'
/4
X
R O
LINE OF EXIST
STRUCTURAL
STEEL JOIST
10 3/4" TYP
C L
O F
LG
ID
A
LU
F
T E
R A
Y P
B D
P
IE
R
R 18' - 4"
05 5000 SLOTTED
CHANNEL
FRAMING - TYP
4'
3'
4'
4'
3'
4'
3' - 0" 4' - 0" 4' - 0"
5'
/8
1/ 2"
5'
/8
/4
10 3/4"
10 3/4"
/4
C2
C3
C3
C3
C3
C3
LINE OF EXIST
STRUCTURAL
STEEL JOIST
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
As Noted
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
A3.1a
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor Reflected Ceiling Plan - Alternate 1
Clio High School Cafeteria Renovation
LEGEND SYMBOL INDICATOR
NOTE: NOT ALL KEYNOTES MAY BE USED
SHADED ITEMS HAVE BEEN REVISED FROM PREVIOUS
REFLECTED CEILING PLAN
KEYNOTES
C1 POCHE INDICATES EXTENT OF 09 5113 ACOUSTICAL LAY-IN CEILING
PANELS AC-02
C2 09 2900 5/8" GYPSUM BOARD ON 09 2216 GRID SUSPENSION
SYSTEM. 09 9600 PAINT (BLACK)
C3 PATCH/REPAIR GYP BD AT PREVIOUS LOCATION OF ALUMINUM
RAFTER BEARING
1/2" = 1'-0"A3.1
ALTERNATE 1 REFLECTED CEILING PLAN - DEMOLITION1
1/2" = 1'-0"A3.1
ALTERNATE 1 REFLECTED CEILING PLAN - NEW WORK2
NOTE: DEMOLITION WORK SHOWN ON THIS PLAN IS IN ADDITION TO THAT WORK SHOWN ON A1.1
50% Owner Review 03-20-2020
U R
S
IN
G D
IM
E
N S
IO
TOP OF FLOOR SLAB
O R
O P
E N
IN
G
S
E E
S C
H E
D U
O R
O P
E N
IN
G
S
E E
S C
H E
D U
DOOR SCHEDULE
A. REFER TO THE DRAWINGS FOR DOOR LOCATIONS
B. "DOOR NUMBER" CORRESPONDS TO THE DOOR NUMBER INDICATED
ON THE DRAWINGS. NOTE: AT EXISTING WALL OPENINGS, FIELD
VERIFY SIZE OF DOORS AND FRAMES.
C. (DOOR) "SIZE" INDICATES THE NOMINAL WIDTH AND HEIGHT OF THE
DOOR IN FEET AND INCHES. ALL DOORS ARE 1 3/4" THICK UNLESS
OTHERWISE NOTED.
D. "DOOR AND FRAME TYPE/MATL/FINISH" INDICATES THE CODES FOR
TYPE (INDICATED ON THE DRAWINGS), MATERIAL AND FINISH.
E. "CC" INDICATES THE COLOR CODE FOR FINISHES OF DOORS AND
FRAMES, SEE "SCHEDULE - COLOR CODES".
F. "DETAILS HEAD- JAMB-SILL" INDICATES THE DETAIL NUMBER
INDICATED ON THE DRAWINGS.
G. "HARDWARE SET" INDICATES HARDWARE SET NUMBERS SPECIFIED IN
08 7100 - DOOR HARDWARE.
H. "DOOR ASSEMBLY RATING" INDICATES THE MINIMUM FIRE
RESISTANCE RATING FOR FIRE DOORS AND/OR SIDELITES.
I. "WALL RATING" INDICATES THE FIRE RESISTANCE RATING OF THE
WALL CONTAINING THE DOOR.
J. "FRGM" INDICATES FIRE-RATED GLAZING MARKINGS.
K. "REMARKS" INDICATES ANY SPECIAL REQUIREMENTS FOR A DOOR
AND FRAME - SEE "DOOR SCHEDULE - REMARKS".
DOOR SCHEDULE
1. ACCESS CONTROL SYSTEM
2. REMOVABLE MULLION
3. LOW ENERGY POWER OPERATED DOOR
4. POWER OPERATED DOOR PACKAGE DOOR ASSEMBLY (ALL
HARDWARE BY DOOR MANUFACTURER)
5. HOLLOW METAL ASTRAGAL
GENERAL REMARKS
REMARKS
08 1416 FLUSH WOOD
08 3326 OVERHEAD COILING GRILLE
NOTE: ALL GLASS TO BE 1/4" SAFETY GLASS EXCEPT USE FIRE RATED GLASS AT FIRE RATED DOORS, SIDELITES, ETC., UON
DOOR TYPE
OHG
08 3326
DOOR TYPE
N 08 1416
3" 6"
3'
2'
5/ 8"
2"
7/16"
4 7/8" AT CMU
PARTITION
WIDTH - SEE PLAN
7/16"
08 1113 HM
FRAME
2 1/4"1 15/16"
FRAME TYPE
08 1113 A
NOTE: ALL GLASS TO BE 1/4" SAFETY GLASS EXCEPT USE FIRE RATED GLASS AT FIRE RATED DOORS, SIDELITES, ETC., UON
A9.1
A9.1
SEE SCHED
W MEETS WALL ASSEMBLY CRITERIA
OH MEETS FIRE WINDOW ASSEMBLY CRITERIA INCLUDING THE HOSE
STREAM TEST
D MEETS FIRE DOOR ASSEMBLY CRITERIA
H MEETS FIRE DOOR ASSEMBLY "HOSE STREAM" TEST
T MEETS 450 DEG F TEMPERATURE RISE CRITERIA FOR 30 MINUTES
NT DOES NOT MEET 450 DEG F TEMPERATURE RISE CRITERIA FOR 30
MINUTES
XXX TIME IN MINUTES OF THE FIRE RESISTANCE OR FIRE PROTECTION
RATING OF THE GLAZING ASSEMBLY
FIRE-RATED GLAZING ASSEMBLIES MARKING
5/ 8"
4"
7/16"
4 7/8" AT CMU
PARTITION
WIDTH - SEE PLAN
7/16"
08 1113 HM
FRAME
2 1/4"1 15/16"
04 2000 CMU
04 2000 BOND BEAM
OR 04 2000 PRECAST
CONCRETE LINTEL
(REF TO SPECIFICATIONS)
3/16"
3/ 8"
VARIES WIDTH -SEE PLAN
07 9200 SEALANT
(BOTH SIDES)
08 1113 HOLLOW METAL FRAME
(REFER TO FRAME TYPE FOR
FRAME PROFILE)
04 2000 GROUT
3/16"
VARIES WIDTH - SEE PLAN
INTERSECTING
WALL CONDITION
4" M
IN
U
O N
07 9200 SEALANT
(BOTH SIDES)
08 1113 HOLLOW METAL FRAME
(REFER TO FRAME TYPE FOR
FRAME PROFILE)
04 2000 GROUT
08 1113 TEE ANCHOR
(08 1113 UL TYPE
ANCHOR AT FIRE
RATED ASSEMBLIES)
04 2000 CMU
09 6543 LINOLEUM
FLOORING
DOOR AND FRAME AS
SCHEDULED
SEE NOTES BELOW
09 3000 METAL
RAMP TRANSITION
09 3000 CERAMIC
TILE (THIN SET)
DOOR STOP
04 2000 8" CMU
08 3326 HOOD
05 5000 STEEL CHANNEL
DOOR FRAME (BEYOND)
08 3326 OVERHEAD
COILING GRILLE
08 3326 DOOR TRACK
07 9200 SEALANT
(BOTH SIDES)
05 5000 STEEL CHANNEL
DOOR FRAME WITH
MITERED
CORNERS. 09 9100 PAINT
(BLACK)
05 5000 GALV STEEL LINTEL
(REFER TO SPECIFICATIONS)
04 2000 CMU
(REFER TO
PLAN). GROUT
SOLID AT
JAMBS
08 3326
OVERHEAD
COILING
GRILLE
08 3326
DOOR TRACK
07 9200 SEALANT
(BOTH SIDES)
05 5000 STEEL CHANNEL
DOOR FRAME WITH MITRED
CORNERS. 09 9100 PAINT (BLACK)
SEE PLAN
04 2000
GROUT
05 5000 STEEL STRAP
ANCHOR (1/8" x 2" x 12"
2'-8" OC VERTICALLY)
8 2
04 2000 #4
VERTICAL
REINFORCING
W/ MATCHING
DOWELS INTO
CONC SLAB.
PROVIDE (2)
BARS AT
JAMB
09 6543 LINOLEUM
FLOORING
09 3000 METAL
RAMP TRANSITION
09 3000 CERAMIC
TILE (THIN SET)
08 3326 OVERHEAD
COILING GRILLE AND
TRACK
FACE OF CMU WALL
(BEYOND)
DOOR STOP
09 6543 LINOLEUM
FLOORING
DOOR AND FRAME AS
SCHEDULED
SEE NOTES BELOW
09 6513 RESILIENT
EDGE STRIP
EXIST CONCRETE
DOOR STOP
09 6543 LINOLEUM
FLOORING
DOOR AND FRAME AS
SCHEDULED
SEE NOTES BELOW
09 6513 RESILIENT
EDGE STRIP
EXIST TERRAZZO
ROOM FINISH SCHEDULE
* REFER TO ABBREVIATIONS LIST FOR MATERIAL CODE DESCRIPTIONS
A. "ROOM NUMBER AND ROOM NAME" CORRESPOND TO THE NUMBER
AND NAMES INDICATED ON THE DRAWINGS.
B. "MATERIAL/FINISH" INDICATE THE SPECIFIC MATERIALS AND FINISHES
TO BE USED TO CONSTRUCT AND FINISH THE FLOORS, BASE, WALLS
AND CEILINGS.
C. "CC" INDICATES THE COLOR CODE FOR EACH MATERIAL AND/OR
FINISH, REFER TO "COLOR CODES".
D. "REMARKS" INDICATES ANY SPECIAL REQUIREMENTS FOR THE
MATERIAL AND FINISH IN A ROOM - SEE "ROOM FINISH SCHEDULE
REMARKS".
E. "CEILING" IS THE MATERIAL AND FINISH AT THE UNDERSIDE OF THE
FLOOR OR ROOF ABOVE. "SOFFIT" IS THE MATERIAL AND FINISH AT
THE UNDERSIDE OF THE STAIR RUN.
F. REFER TO A10 SERIES FOR MATERIAL LOCATION WHERE MULTIPLE
FLOOR OR WALL FINISHES ARE INDICATED ON FINISH SCHEDULE.
G. REFER TO A8 SERIES FOR INTERIOR ELEVATIONS.
H. "E" PREFIX TO THE "PT" CODE REFER TO EPOXY PAINT MATERIAL
(E PT-XX).
ROOM FINISH SCHEDULE
1. GROUT TO BE GRT-01
2. EXTENT OF NEW BASE TO MATCH EXTENT OF NEW FLOORING
3. INSTALL NEW RESILIENT BASE TO MATCH EXISTING.
GENERAL REMARKS
REMARKS
09 6543
LINOLEUM
FLOORING
EXIST TERAZZO
FLOORING
09 6513
RESILIENT
EDGE STRIP
1' - 0" 1' - 0"
2'
2'
4'
2' - 0"
PROVIDE (4) 09 3000 12" X 24"
TILE UNITS AS INDICATED TO
CREATE 24" X 48" FIELD, TYP
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
As Noted
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas, E. Trevarrow
A9.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
20116-1000
1 Mustang Drive Clio, Michigan 48420
Room Finish Schedule, Door Schedule and Details
Clio High School Cafeteria Renovation
1/4" = 1'-0"
DOOR TYPES
3" = 1'-0"
FRAME - HM1
1/4" = 1'-0"
FRAME TYPES
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME DETAILS
HARDWARE
SET
DOOR
ASSEMBLY
RATING
WALL
RATING REMARKS
SIZE
TYPE MATERIAL FINISH/ CC FRGM TYPE MATERIAL FINISH / CC FRGM HEAD JAMB SILLWIDTH LEAF 1 LEAF 2 HEIGHT
100a 3' - 0" 3' - 0" 7' - 0" F (E) - (E) - - - 9/A9.1 -
101 3' - 0" 3' - 0" 7' - 0" F (E) - (E) - - - 10/A9.1 -
102a 3' - 0" 3' - 0" 7' - 0" N WD WD-01 - A HM PT-02 - 3/A9.1 5/A9.1 7/A9.1 1 - -
102b 7' - 4" 8' - 0" OHG AL AL-01 - - AL AL-01 - 4/A9.1 6/A9.1 8/A9.1 2 - -
WM WIRE MESH
WD WOOD
STL STEEL
ST STL STAINLESS STEEL
STN STAIN
PVF POLYVINYL FLUORIDE COATING (KYNAR)
PT PAINT
P LAM PLASTIC LAMINATE
MATL MATERIAL
HDWE HARDWARE
HM HOLLOW METAL
20 20 MINUTES
E/45 E LABEL / 45 MINUTES (EXTERIOR)
D/90 D LABEL / 90 MINUTES (EXTERIOR)
C/45 C LABEL / 45 MINUTES
B/60 B LABEL / 60 MINUTES
B/90 B LABEL / 90 MINUTES
A/180 A LABEL / 180 MINUTES
FAC FACTORY
FRP FIBERGLASS REINFORCED PANEL
(E) EXISTING
CC COLOR CODES
ANOD ANODIZED
ALUM ALUMINUM
DOOR SCHEDULE
ABBREVIATIONS
3" = 1'-0"
FRAME - HM2
3" = 1'-0"
HEAD3
3" = 1'-0"
JAMB5
3" = 1'-0"
SILL7
3" = 1'-0"
HEAD - OVERHEAD COILING GRILLE4
3" = 1'-0"
JAMB - OVERHEAD COILING DOOR6
DR SCH
A9.1
A9.1DR SCHDR SCH
DR SCH
DR SCH3" = 1'-0"
SILL8
DR SCH
3" = 1'-0"
SILL9
DR SCH
3" = 1'-0"
SILL10
DR SCH
WDF WOOD FLOOR (ATHLETIC/T&G)
WD WOOD
WC WALL COVERING
VCT VINYL COMPOSITION TILE
TP TOILET PARTITIONS
TK TACKBOARD
TER TERRAZZO
TC TRAFFIC COATING
ST STL STAINLESS STEEL
ST STAIN
SS SOLID SURFACE MATERIAL
SC SHADE CLOTH
RT RESILIENT TILE
RS RESILIENT SHEET
RTR RESILIENT TREAD/RISED (RUBBER/VINYL)
QZ QUARTZ SURFACE
QT QUARRY TILE
PT PAINT
PL PLASTIC LAMINATE
PC PRIVACY CURTAIN
MBL MARBLE
MTL METAL
LVT LUXURY VINYL TILE
LN LINOLEUM
LK LOCKER
GRT GROUT
GYP GYP BOARD CEILING
GF GROUND FACE CMU
FP FABRIC WRAPPED PANEL
FC FLOOR COATING (EPOXY)
FT FLOOR TILE
FF ARCHITECTURAL FINISH FILM (GLAZING)
EXP EXPOSED CONST/PAINTED
ER EPOXY RESIN
ENT ENTRY MAT/CARPET
E PT EPOXY PAINTED
CPT CARPET (TILE/BROADLOOM)
CONC CONCRETE
CK CORK
CG CORNER GUARD
BR BRICK
BB BURNISHED BLOCK
B BASE
AL ANODIZED ALUMINUM
AF ACOUSTICAL FABRIC CELING
AC ACOUSTICAL CEILING PANEL
AB ACOUSTICAL BAFFLE
ROOM FINISH SCHEDULE
ABBREVIATIONS
SCHEDULE - COLOR CODES
COLOR CODES PRODUCT / MATERIAL MANUFACTURER PRODUCT NAME / NUMBER COLOR NAME / NUMBER SIZE FINISH NOTES
AC-01 ACOUSTICAL CEILING PANEL ARMSTRONG SCHOOL ZONE - FINE FISSURED / 1714 WHITE 24 X 48 PRELUDE XL GRID
AC-02 ACOUSTICAL CEILING PANEL ARMSTRONG CLEAN ROOM VL UNPERFORATED / 870 WHITE 24 X 48 PRELUDE XL GRID
AC-03 ACOUSTICAL CEILING PANEL ARMSTRONG CLEAN ROOM VL UNPERFORATED / 868 WHITE 24 X 24 PRELUDE PLUS XL ALUM GRID
AL-01 ANODIZED ALUMINUM REFER TO SPEC - CLEAR ANODIZED - OVERHEAD COILING GRILLE
B-01 RESIL BASE JOHNSONITE TRADITIONAL VINYL WALL BASE (1/8") BLACK / 40 6" MATCH EXISTING
B-02 TILE BASE MARAZZI MODERN FORMATION SMOKY RIDGE / P-36C9T 6 X 12 COVE BASE
E PT-01 PAINT BENJAMIN MOORE - LATTE / SW 6108 - GENERAL
FT-01 FLOOR TILE MARAZZI MODERN FORMATION CANYON TAUPE / MF03 12 x 24 STEPWISE
FT-02 FLOOR TILE MARAZZI MODERN FORMATION MESA POINT / MF06 12 x 24 STEPWISE
FT-03 FLOOR TILE MARAZZI MODERN FORMATION SMOKY RIDGE / MF05 12 x 24 STEPWISE
GRT-01 GROUT TEC INCOLOR / 575 SABLE / 925 -
GYP-01 GYPSUM BOARD CEILING
LN-01 LINOLEUM SHEET FORBO MARMOLEUM MARBLE / 2939 BLACK FRESCO / 2939
LN-02 LINOLEUM SHEET FORBO MARMOLEUM MARBLE / 3246 SHRIKE / 3246
PT-01 PAINT SHERWIN WILLIAMS - ELECTRIC ORANGE / 2015-10 - ACCENT - ORANGE
PT-02 PAINT BENJAMIN MOORE - LATTE / SW 6108 - HM DOOR FRAMES
WD-01 WOOD DOOR REFER TO SPEC - MATCH EXISTING - MATCH EXISTING
SCHEDULE - ROOM FINISH
NUMBER NAME
FLOOR BASE WALL CEILING
REMARKSMATERIAL/FINISH MATERIAL/FINISH
101 CAFETERIA LN-01, LN-02 (E) B-01 (E), PT-01 AC-01 2,3
102 FOOD SERVICE AREA FT-01, FT-02, FT-03 B-02 E PT-01 AC-03 1
104 JANITORS CLOSET - - - GYP-01, PT-02 3
105 SERVING - - - AC-02
6" = 1'-0"A10.1
TERAZZO TO LINOLEUM TRANSITION11
50% Owner Review 03-20-2020
Quality Management Review 04-03-2020
Bids 06-12-2020
1/2" = 1'-0"A10.1
FLOOR TILE INSTALLATION12
INTERIOR PARTITIONS
1. "WALL" AND "PARTITION" ARE USED TO DENOTE EITHER WALLS OR
PARTITIONS INTERCHANGEABLY.
2. REFER TO DRAWING AR.0 - ARCHITECTURAL REFERENCE
INFORMATION FOR ABBREVIATIONS, SYMBOLS, AND GRAPHIC
INDICATIONS.
3. REFER TO COMPOSITE LIFE SAFETY PLANS FOR PARTITION FIRE
RATINGS.
4. REFER TO ROOM FINISH SCHEDULE FOR WALL FINISHES AND WALL
BASE.
GENERAL NOTES
ASSEMBLY RATING
S = SMOKE PARTITION
0 = NON-RATED
1 = 1-HR FIRE RATED
2 = 2-HR FIRE RATED
3 = 30 MIN FIRE RATED
PARTITION TYPE
GRAPHIC TAG
PARTITION SERIES
SIZE DESIGNATOR
(SEE TABLE BELOW)
MATERIAL
MASONRY
STEEL STUDS
FURRING
SHAFTWALL
C-H STUDS
DESIGNATION SIZE ACTUAL SIZE SPACING
N/A
16" OC
16" OC
24" OC
3 5/8 " 5 5/8 " 7 5/8 "
11 5/8 "
1 5/8 " 2 1/2 " 3 5/8 "
4" 6"
7/8 " 1 5/8 " 2 1/2 " 3 5/8 "
2 1/2 " 4" 6"
5. SUBSTITUTE 09 2900 - TILE BACKING BOARD AT LOCATIONS TO
RECEIVE A TILE WALL FINISH.
6. ALL NON-LOAD BEARING METAL WALL FRAMING SHALL BE BASED ON
TOTAL STUD HEIGHT. REFER TO SPECIFICATION SECTIONS 05 4000 -
COLD-FORMED METAL FRAMING, 09 2116 - GYPSUM BOARD SHAFT
WALL ASSEMBLIES AND 09 2216 - NON-STRUCTURAL METAL FRAMING
FOR ADDITIONAL REQUIREMENTS.
7. WHERE ROOMS WITH DIFFERENT PARTITION REQUIREMENTS ARE
ADJACENT, THE PARTITION WITH THE GREATER FIRE-RATING AND/OR
STC SHALL BE USED BETWEEN THEM.
8. AT INTERSECTIONS OF DIS-SIMILAR PARTITON TYPES, THE HIGHEST
RATED PARTITION IS TO RUN THROUGH THE INTERSECTION TO
MAINTAIN ENCLOSURE. MAINTAIN RATING OF RATED PARTITION AT
INTERSECTION WITH COLUMN ENCLOSURES BY EXTENDING RATED
CLOSURE AS REQUIRED.
9. FIRE-RATED PARTITIONS SHALL BE CONSTRUCTED ACCORDING TO
THE FIRE TEST INDICATED. NO SUBSTITUTIONS OF MATERIALS OR
DEVIATIONS FROM CONSTRUCTION ARE ALLOWED. ADDITIONAL
LAYERS MAY BE REQUIRED FOR ACOUSTICAL OR OTHER REASONS
AND MUST BE EXECUTED AS SHOWN.
10. STC RATINGS ARE MINIMUM ACOUSTICAL PERFORMANCE
REQUIREMENT. SPECIFIC ACOUSTICAL TESTS ARE GIVEN FOR
REFERENCE ONLY. SOUND ATTENUATION BLANKET THICKNESS
SHALL BE AS FOLLOWS:
A. 1 1/2 " FOR PARTITIONS WITH 1 5/8 " AND 2 1/2 " STUDS
(INCLUDING SHAFTWALLS).
B. 3" FOR PARTITIONS WITH 3 5/8 ", 4" OR 6" STUDS.
C. 3" FOR SHAFTWALLS WITH 4" OR 6" STUDS UNO.
D. AS REQUIRED FOR FIRE RATING.
11. DETAILS ARE DIAGRAMMATIC - PRECISE REQUIREMENTS OF TESTS
ASSEMBLIES SHALL GOVERN.
XXX
FIRST FLOOR
100' - 0"
V
IF
EXIST CONC DECK
PARTITION TYPE AS
INDICATED ON FLOOR
PLAN
BASE AS SCHEDULED
CEILING AS
SCHEDULED. REF TO
REF CLG PLAN AND
FINISH SCHEDULE
REF TO PARTITION
SERIES FOR HEAD
OF WALL DETAIL
DASHED AREA
REPRESENTS 04 2000 8"
CMU INFILL. PROVIDE #4
VERTICAL REINFORCING
AND MATCHING DOWELS
AT 48" OC
08 1600 WD DOOR AND
08 1113 HM FRAME
26 0000 ELEC DEVICE.
REF TO ELEC DRAWINGS
05 5000 STEEL CHANNEL
JAMBS. 09 9100 PAINT
(BLACK)
05 5000 GALV STEEL
LINTEL. REF TO
SPECIFICATIONS
08 3326 OVERHEAD
COILING GRILLE
09 9100 PAINT (PT-01) ON
NEW/EXIST CMU
0B
1B
3"
1/2"
PARTITION TYPE -
REF TO FLOOR PLAN
09 2900 ALUM J-TRIM
07 9200 JOINT
SEALANT
07 8413 MINERAL
FIBER INSULATION
PACKED IN STUD
CAVITY
07 8413 FIRESTOPPING
SEALANT
RETURN 09 2900
GYPSUM BOARD TO
MAINTAIN FIRE RATING
PARTITION TYPE -
REF TO FLOOR PLAN
FACE OF EXIST CMU
WALL
SB2
05 3100 STEEL DECK CLOSURE
(CONT) WHERE EXPOSED TO VIEW
UNDERSIDE OF DECK
3/4" STRUCTURAL
DEFLECTION ALLOWANCE
CEILING AS SCHEDULED
BASE AS SCHEDULED
07 8413 HEAD OF WALL FIRE
RESISTIVE JOINT SYSTEM AT
RATED PARTITIONS
CONSTRUCTION AT VOIDS
OF STEEL DECK ONLY
09 2216 SLOTTED DEFLECTION
TRACK (SECURED TO DECK)
UL U419
UL U419
UL U419
UL U419
2B2
SB3
SB4
SB6
2B3
2B4
2B6
UL U411
UL U411
UL U411
UL U411
0B2 1B2 3B2
0B3 1B3 3B3
0B4 1B4 3B4
0B6 1B6 3B6
5"
6 1/8"
6 1/2"
8 1/2"
09 2216 METAL STUDS
09 2900 5/8" GYPSUM BOARD
(2 LAYERS @ 2-HR FIRE
RATED PARTITION)
09 2216 METAL RUNNER
CHANNEL (SECURED TO
FLOOR)
09 2900 ACOUSTICAL SEALANT
(CONT BOTH SIDES - OMIT
WHEN CARPET RUNS UNDER
PARTITION)
09 2900 SOUND ATTENUATION
INSULATION TO DECK ABOVE
09 2900 SOUND
ATTENUATION INSULATION
3 3/4"
4 7/8"
5 1/4"
7 1/4"
1'
EXTEND 09 2900 GYPSUM
BOARD PAST FASCIA
EDGE 3"
CLG HT
REF TO REF CLG PLAN
CLG HT
REF TO REF CLG PLAN
TOP OF EXIST WALL
9' - 4" AFF ±, VIF
CL
OF THREADED ROD AND
EXIST WALL BELOW
REINSTALL SALVAGED 2X8
ALUM RAFTERS AND WALL
MOUNTING PLATE. MATCH
EXIST CONFIGURATION AND
LOCATION
09 2900 5/8" GYPSUM BOARD
ON 09 2216 GRID
SUSPENSION SYSTEM
09 2900 EDGE TRIM
07 9200 SEALANT
9' - 4" ± VIF
EXIST STRUCTURAL STEEL JOIST
05 5000 SLOTTED CHANNEL FRAMING
ATTACHED TO BTM CHORD OF EXIST
STRUCTURAL STEEL JOIST
05 5000 1/2" THREADED ROD. PROVIDE
07 9200 SEALANT AT GYPSUM BOARD
PENETRATION
DRILL HOLE THROUGH EXIST ALUM
RAFTER FOR THREADED ROD
09 5113 ACOUSTICAL LAY-IN CEILING
PANELS IN EXPOSED METAL
SUSPENSION SYSTEM W/ 14"
PREFINISHED METAL PERTIMETER
FASCIA TRIM
EXIST CMU W/ 09 9600 PAINT
TO MATCH EXIST
ALIGN
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
As Noted
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas
A9.2
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
20116-1000
1 Mustang Drive Clio, Michigan 48420
Partition Types, Interior Details and Interior Elevations
Clio High School Cafeteria Renovation
3/4" = 1'-0"A2.1
INTERIOR WALL SECTION2
1/4" = 1'-0"A2.1
INTERIOR ELEVATION - CAFETERIA 101 EAST3
1 1/2" = 1'-0"A2.1
PLAN DETAIL1
PARTITION SERIES 'B'
1" = 1'-0"A3.1a
SECTION THRU SERVING 105 CEILING - ALTERNATE 14
50% Owner Review 03-20-2020
LEGEND
FINISH PLAN
NOTE: NOT ALL SYMBOLS MAY BE USED
FLOOR TILES FT-03
XX-XX
FLOOR COLOR CODE TAG- REFER TO ROOM FINISH SCHEDULE
DRAWING A9.1
09 6813 TILE CARPETING INSTALLATION METHOD - ASHLAR
09 6813 TILE CARPETING INSTALLATION METHOD - MONOLITHIC
FLOOR MATERIAL TRANSITION TAG
REFER TO A.XX FOR TRANSITION/ SILL DETAILS
FLOOR TILES FT-01
FLOOR TILES FT-02
09 6813 TILE CARPETING INSTALLATION METHOD - QUARTER TURN
N-D
09 6813 TILE CARPETING INSTALLATION METHOD -
NON-DIRECTIONAL
LINOLEUM FLOORING LN-01
LINOLEUM FLOORING LN-02
X X
FLOORING INSTALATION DIRECTION
XX-XX ACCENT MATERIAL, REFER TO COLOR CODES
A. REFER TO ROOM FINISH SCHEDULE AND COLOR CODES FOR MORE
INFORMATION.
FINISH PLAN
GENERAL NOTES
FT LN
(E
T E
R R
LN
LN
(E
CAFETERIA
FOOD
SERVICE
AREA
FT LN
JANITORS
CLOSET
PT-01
PT-01
ALIGN
5' - 4" ±
SERVING
11' - 6 3/4" 35' - 0" ±
EXTENT OF NEW
CAFETERIA
FLOORING
ALTERNATE NO. 2
A9.1
T Y
P
4'
TYP
2' - 0"
A9.1
1' - 6"
1'
1' - 6" 1' - 6"
1'
1' - 6"
1'
EXIST
TERRAZZO
FLOORING
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
E. Trevarrow
A10.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
1/4" = 1' - 0"
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor - Finish Plan
Clio High School Cafeteria Renovation
50% Owner Review 03-20-202050% Owner Review 03-20-2020
A. ITEMS SHOWN IN GRAYSCALE ARE FOR REFERENCE ONLY.
B. COORDINATE THE INTERFACING OF ALL TRADES WITH RESPECT TO
DELIVERY AND INSTALLATION OF ALL FURNITURE, FIXTURES AND
EQUIPMENT
C. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS BEFORE
INSTALLATION. CONSULT ARCHITECT WHEN ACTUAL FIELD
CONDITIONS VARY FROM THOSE SHOWN ON CONSTRUCTION
DOCUMENTS.
D. COORDINATE LOCATIONS OF ALL REQUIRED UTILITIES WITH THE
TRADE PROVIDING THE SAME. REFER TO MECHANICAL AND
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
FURNITURE FIXTURE AND EQUIPMENT PLAN
GENERAL NOTES
FSE-5
FSE-1
FSE-3
FSE-4
FSE-1
FSE-1
FSE-2
FOOD
SERVICE
AREA
JANITORS
CLOSET
SERVING
SERVING
CAFETERIA
JANITOR
CLOSET
JANITOR
CLOSET
100A
WOMEN'S
TOILET
ROOM
PLUMBING
CHASE
MEN'S
TOILET
ROOM
STORAGE
STORAGE
OFFICE
VESTIBULE
FSE-9
FSE-6
FSE-7
FSE-8
FSE-10
ST1 (24)
T1 (6)
N O
R T
H
Project Title
Key Plan c
Project Designer
Q.M. Review
Approved
Drawing Scale
Project Number
Project Architect / Engineer
Drawn By
Project Administrator
2020 , LLC
Drawing Number
Issued for Issue Date
IDS Drawing Title
1441 west long lake, suite 200 troy, michigan 48098
5211 cascade road SE, suite 300 grand rapids, michigan 49546
248.823.2100 www.ids-michigan.com
For Reference Only architecture engineering interiors & technology
I N T E G ETR A D SOLUT SNIO
I N TEG ETRA D SOLU T SNIO
i D s
B
IM
C
A S
D C lio H ig h
S ch oo l C af et er ia
R en o/
C A
S D
H S
C af et er ia R en ov at io n- A
.rv t 6/
/2
:4
5:
A M
B. Sundberg
B. Sundberg
C. Haas, E. Trevarrow
F2.1
C. Haas, E. Trevarrow
B. Snyder
C. Haas
Clio Area School District
1/4" = 1' - 0"
20116-1000
1 Mustang Drive Clio, Michigan 48420
First Floor Furniture Plan
Clio High School Cafeteria Renovation
SCHEDULE - KITCHEN EQUIPMENT (EQUIPMENT BY OWNER)
EQUIPMENT TAG (REF TO PLAN) MANUFACTURER MODEL NO. PRODUCT DESCRIPTION DIMENSIONS ELECTRICAL REQUIREMENTS
MECHANICAL/PLUMBING
REQUIREMENTS NOTES
FSE-1 VOLLRATH 37023 SIGNATURE SERVER UTILITY SERVING COUNTER 74"W X 28"D X 34"H N/A N/A
FSE-2 TURBO-AIR M3F47-2-N 2-DOOR TOP MOUNT REACH-IN FREEZER 51-3/4"W X 30-3/4"D X 78"H 115V/60HZ/1-PH, 6.3 AMPS N/A
FSE-3 DONPER XC336 THREE FLAVOR FROZEN BEVERAGE MACHINE 23.6"W X 18.9"D X 31.75"H 115V/60HZ/1-PH
FSE-4 NOR-LAKE CTB71-17 CURVED LID DISPLAY FREEZER WITH SLIDING GLASS DOORS 66-1/2"W X 27-3/8"D X 33-1/2"H 115V/60HZ/1-PH, 2.8 AMPS N/A
FSE-5 HOWARDS-MCCRAY SC-OD30E-5L-B-L
ED
OPEN DAIRY MERCHANDISER DISPLAY CASE 63"W X 30"D X 60"H 115/208-230V/60HZ/1-PH, 11.3 AMPS N/A
FSE-6 HATCO GR2SDH-42D GLO-RAY DESIGNER COUNTERTOP HORIZONTAL DISPLAY WARMER 48-1/4"W X 27"D X 18.11"H 120/208V/60HZ/1-PH, 12.4 AMPS N/A
FSE-7 WINCO EDM-2 HOT FOOD DISPLAY MERCHANDISER 17-3/5"W X 18-1/10"D X 30-9/10"H 120V/60HZ/1-PH, 7.2 AMPS N/A
FSE-8 VOLLRATH 37015 SIGNATURE SERVER CASH REGISTER STAND 28"W X 28"D X 34"H N/A N/A POINT OF SALE REGISTER NOT INCLUDED. CART TO
BE STORED WITHIN FOOD SERVICE ARE AND
WHEELED OUT TO CAFETERIA WHEN OPERATING
FSE-9 AMANA RMS10TSA 0.8 CU FT 1000 WATT COMMERCIAL MICROWAVE OVER WITH TOUCH
PAD
20"W X 15.9"D X 12.25"H 120V/60HZ/1-PH, 15 AMPS N/A
FSE-10 BK RESOURCES BKHS-D-1410 STAINLESS STEEL HAND SINK 17"W X 17"D X 13"H N/A BKF-4DM-5G-G OPTIFLOW
HEAVY DUTY SOLID BODY
FAUCET, DECK MOUNT
50% Owner Review 03-20-2020
AIR ADMITTANCE VALVE
AAV
AC
ACU
AD
AE
AFF
AFT
AHU
APD
APPROX
ARCH
ASR
AIR COMPRESSOR
AIR CONDITIONING UNIT
ACCESS DOOR
AIR EXTRACTOR
ABOVE FINISHED FLOOR
AIR FLOW TRANSMITTED
AIR HANDLING UNIT
AIR PRESSURE DROP
APPROXIMATELY
ARCHITECTURAL
AUTOMATIC SPRINKLER RISER
ABBREVIATIONS
BUILDING AUTOMATION SYSTEM
B
BAS
BBD
BF
BFP
BHP
BP
BWV
BOILER BLOWDOWN
BARRIER FREE
BOILER FEEDWATER PUMP
BRAKE HORSEPOWER
BACKFLOW PREVENTER
BACKWATER VALVE
CAPACITY
C
CAP
CC
CD
CFH
CFM
CI
CLG
COILING COIL
COLD DECK
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CAST IRON
CEILING
CO
COND
CONN
CON'T
CONTR
CONV
CLEANOUT
CONDENSATE
CONNECTION
CONTINUATION
CONTRACTOR
CONVECTOR
CPU
CR
CT
CUH
CV
CW
CENTRAL PROCESSING UNIT
CONDENSATE RETURN
COOLING TOWER
CABINET UNIT HEATER
CONTROL VALVE
COLD WATER
D
DRY BULBDB
DDC
DEG
DN
D/N
DPR
D&T
DTC
DIRECT DIGITAL CONTROL
DEGREES
DOWN
DAY/NIGHT
DAMPER
DRIP & TRAP
DRAIN TILE CONNECTION
EXHAUST AIR
E
EA
EAT
EDB
EF
EG
EHC
EIH
ENTERING AIR TEMPERATURE
ENTERING DRY BULB
EXHAUST FAN
EXHAUST GRILLE
ELECTRIC HEATING COIL
ELECTRIC INFRARED HEATER
EJ
EV
ELEC
EMCS
ENT
ER
EXPANSION JOINT
ELEVATION
ELECTRICAL
ENERGY MONITORING AND CONTOL SYSTEM
ENTERING
EXHAUST REGISTER
ERC
ES
ESP
ET
EWB
EWC
ENERGY RECOVERY UNIT
EMERGENCY SHOWER
EXTERNAL STATIC PRESSURE
EXPANSION TANK
ENTERING WET BULB
ELECTRIC WATER COOLER
EWT
EXH
(E)
EXP
ENTERING WATER TEMPERATURE
EXHAUST
EXISTING
EXPANSION
FARENHEIT
F F
FA
F & BD
FC
FCO
FACE AREA
FACE AND BYPASS DAMPER
FLEXIBLE CONNECTION
FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
F CONT
FIRE DAMPERFDAMP
FH
FHC
FHV
FL
FIRE HYDRANT
FIRE HOSE CABINET
FIRE HOSE VALVE
FIRE LINE
FLA FULL LOAD AMPS
FMS FLOW MEASUREMENT STATION
FPM
FT
F&T
FTR
FEET PER MINUTE
FOOT/FEET
FLOAT & THERMOSTATIC STEAM TRAP
FINNED TUBE RADIATION
FVC FIRE VALVE CABINET
GAGE/GAUGE
G
GA
GALV
GPM
GPH
GR
GV
GALVANIZED
GALLONS PER MINUTE
GALLONS PER HOUR
GRILLE
GATE VALVE
HUMIDIFIER
H
HUMD
HB
HD
HO
HOA
HP
HOSE BIBB
HOT DECK
HUB OUTLET
HAND-OFF-AUTO
HORSEPOWER
HP STM
HV
HVAC
HYD
HIGH PRESSURE STEAM
HEATING AND VENTILATION UNIT
HEATING, VENTILATION & AIR CONDITIONING
HYDRANT
INSIDE DIAMETER
I
ID
IE
IW
INVERT ELEVATION
INDIRECT WASTE
L
LAVATORYLAV
LBS/HR
LL
LP
LP STM
POUNDS PER HOUR
LOW LIMIT
LIGHTING PANEL
LOW PRESSURE STEAM
LRA LOCKED ROTOR AMPS
LWT LEAVING WATER TEMPERATURE
MIXED AIR
M
MA
MAV
MAX
MBH
MCC
MECH
MANUAL AIR VENT
MAXIMUM
THOUSAND BRITISH THERMAL UNITS PER HOUR
MOTOR CONTROL CENTER
MECHANICAL
MFR
MGV
MH
MIN
MANUFACTURER
MASTER GAS VALVE
MAN HOLE
MINIMUM
MS
MZ
MOTOR STARTER
MULTI-ZONE UNIT
NORMALLY CLOSED
N
NC
NCR
NIC
NO
No.
NTS
NOISE CRITERION
NOT IN CONTRACT
NORMALLY OPEN
NUMBER
NOT TO SCALE
OUTSIDE AIR
O
OA
OD
OED
OS&Y
OV
OUTSIDE DIAMETER
OPEN ENDED DUCT
OUTSIDE SCREW AND YOKE
OUTLET VELOCITY
P
PUMPP
PA
PAC
PCR
PD
PIPE ANCHOR
PACKAGED AIR…
This is the start of the file's text. The full file is on GovTribe.