10 kW REV Dryer Expected Utility and Footprint Requirements
(Not Intended for Construction)
Installation located in USA Project: US Army CCDC SC
August 25, 2020
Confidential Proprietary
The REV dryer described in this document is not intended for pharma GMP applications.
If the dryer is expected to be part of a GMP installation, please contact Brent Charleton at bcharleton@enwave.net
Revision 0 (A Valerio 2020) Please contact service@enwave.net for any questions or concerns related to the contents of this document mailto:bcharleton@enwave.net mailto:service@enwave.net
10 kW REV Confidential Proprietary
Description: Possible equipment distribution.
Drawing units: NA.
View: Isometric view / footprint.
Model: nutraREV-Test-2450-10 Description: REV dryer with Magnetrons on the side.
The room temperature where the 10kW REV dryer is installed needs to be >19C but not higher than 30C. It is highly recommended to install the REV dryer in a temperature controlled room.
Description: Possible equipment distribution.
Drawing units: Inches.
View: Top view / footprint. 3
10 kW REV Confidential Proprietary
A minimum unobstructed clearance equal to 3 ft. between and around every components is recommended (pump skid, main chamber and electrical cabinet).
Door opening direction
MW head opening direction
Description: Possible equipment distribution.
View: Front view / footprint.
HMI (Human Machine Interface)
.5
Process Status Lights
A minimum unobstructed ceiling height equal to 10 ft. is recommended.
10 kW REV Confidential Proprietary
Description: Drying drum detail.
View: Selected views.
3 drying drums provided with the nutraREV basket system
- Material: Food grade rotary molded PP.
- Weight: Approx. 17.5 lb. each when empty.
10 kW REV
Proprietary
Description: Drying tray detail.
View: Selected views.
10 units provided with the Ferris wheel tray-handling system
- Material: Food grade co-poly PP.
- Weight: Approx. 3.5 lb. each when empty.
10 kW REV
List of pipes/conduit/hoses provided by EnWave to interface the components of the 10kW REV dryer
• Pump Skid to Main Chamber:
• (1) Cooling water to condenser: Water hose (3/4”) [2 hoses 15 ft. long]
• (2) Cooling water to magnetrons: 2 x Water hose (3/4”) [2 hoses 15 ft. long]
• (3) Vacuum line: 2” Vacuum hose (tri-clamp) [1 hose 15 ft. long]
• Pump Skid to Electrical Cabinet:
• (4) Power/control wires: 1” electrical conduit [2 conduits 30 ft. long]
• Electrical Cabinet to Vacuum Chamber:
• (5) Power/control wires: 5 x 1” electrical conduit [5 conduits 15 ft. long]
• (6) Plastic tubing: 1 x ¼” plastic tubing [1 plastic tubing 15 ft. long]
Pump Skid
Main Chamber
Electrical Cabinet
10 kW REV
The connections and utilities that US Army CCDC SC needs to procure:
• (A) Power to the electrical cabinet: 208V/3phase/80A/60Hz. More details in page 14.
• (B) Cooling water to the pump skid: 15GPM at 45PSI (5C to 15C) cooling capacity of at least 6 Ref Tons (>21 kW). The standard pump skid is equipped with 1” NPT female supply and return connections. Please specify if a different connection standard is required. We can supply 1” male BSPT converters or 1.5” TC fittings if requested. Please request these by email to avalerio@enwave.net. More details in pages 15 and 16.
• (C) Compressed air to the pump skid: 1 CFM at 90 PSI (we provide a ¼” plastic tubing to connect the compressed air supply). Please specify if a different connection standard is required. More details in page 17.
• (D) Wired Internet connection to the electrical cabinet: Ethernet cable connection. Highly recommended for maintenance and troubleshooting but not critical for operation. More details in page 18.
• (E) Water to fill the buffer tank in the pump skid: This is not a continuous water supply. The buffer tank may need to be top-up every week or every time the level is too low. This does not need to be a permanent installation (e.g. a water hose can be used for this purpose). An example in page 19.
B
C
A D
Pump Skid
Main Chamber
Electrical Cabinet
List of drainage points in the REV dryer
• (G) Drying chamber (washing water) [2” TC connection]: This drainage is used to drain washing fluids form the main chamber. Shown in pages 9 and 10.
• (H) Surge tank / condenser (condensation water from the product and washing fluids) [1.5” TC connection]: This drainage point is used to drain the condensed water of the drying process. Shown in pages 9 and 11.
• (I) Pump skid (cooling water) [1.5” TC connection]: This drain is used to remove the excess of cooling water in the pump skid.
Shown in pages 12 and 13.
NOTE: The drainage segregation should be done in accordance to local regulations by US Army CCDC
SC.
H
IG
E
10 kW REV Confidential mailto:avalerio@enwave.net
Drain (G)
Drain (H)
Drains on the Main Chamber 10 kW REV Confidential
Drain (G)
10 kW REV
Drain (H)
10 kW REV
Drain (I)
Drains on the Pump Skid
10 kW REV Confidential
Drain (I)
10 kW REV
Utility Requirements Specification
(A) Power to the electrical cabinet
• Single connection point procured by US Army CCDC SC: 208V/60Hz/3phase/80A.
• The connection of the electrical cabinet to the electrical mains of the installation facility is out of EnWave’s scope of work (not procured by EnWave). US Army CCDC SC should provide a professional electrician to perform this connection in accordance to local standards.
• The main circuit breaker where the electrical connection needs to be done is in the electrical cabinet (as shown in the picture). Cables are fed from the top of the cabinet.
Ground
Mains connection
10 kW REV
(B) Cooling water to the pump skid
• Single connection point procured by US Army CCDC SC: 5°C to
15°C. Minimum required flow rate: 15 GPM. Minimum pressure:
45 psi. Clean filtered water in accordance to local standards.
• If sufficient cooling water supply is not available at the installation facilities. This requirement could be covered with a chiller with a cooling capacity larger than 6 Ref Tons (>21 kW) (conceptual example in page 16). EnWave does not provide this chiller or any other means to supply this cooling water requirement (e.g. chiller, filter, expansion tank, etc.).
• The connection of the REV pump skid to your cooling water supply (e.g. chiller) is out of EnWave’s scope of work. US Army CCDC SC should provide a technician to perform this connection.
• The standard connection supplied with the REV pump skid is 1” NPT female. US Army CCDC SC needs to specify if a different connection is needed (email to avalerio@enwave.net).
Supply
Return
10 kW REV Confidential
Note: The components in the green dotted rectangle (including the blue and red hoses) are not supplied by EnWave and need to be procured/supplied by US Army CCDC SC.
This is a possible conceptual sketch of the interface between the pump skid (EnWave’s dryer) and the chiller (provided by US Army CCDC SC). The sketch does not show the detail of the valves and regulators needed in accordance to local regulations.
10 kW REV Confidential
(5C to 15C)
(C) Compressed air to the pump skid
• Single connection point procured by US Army CCDC SC: 1CFM @ 90 psi. Filtered dry air in accordance with local standards.
• The compressed air supply needs to be connected to the compressed air connection provided with the pump skid. This compressed air connection is a 1/4” OD plastic tubing. US Army CCDC SC needs to specify if a different connection is needed (please send an email to avalerio@enwave.net).
• The required compressor, filter and connection of the compressed air line is out of EnWave’s scope of work (not procured by EnWave).
Most of our partners use 1/4” OD push in fitting
Compressed air tube in the pump skid that needs to be connected to the compressed air supply (1/4” OD plastic tubing at the right).
10 kW REV Confidential
(D) Wired Internet connection to the electrical cabinet
• This connection is highly recommended but not mandatory for the operation of the REV dryer.
• Single connection point procured by US Army CCDC SC: Hard wired
Internet connection (5, 5e, 6, 6a).
• US Army CCDC SC needs to procure the connection of the electrical cabinet to the IT infrastructure.
• The Ethernet receiver is located in the electrical cabinet as shown in the photograph. The internet connection is only used for remote access and service.
• The connection will use eWon Cosy 131 (static IP). Some ports may be open for that static IP.
Ethernet connection
10 kW REV
Note: The components in the green dotted rectangle are not supplied by EnWave and need to be procured/supplied by US Army
CCDC SC.
10 kW REV
Anchoring points for the main chamber
Holes compatible with ½” threaded bars/anchors
Anchoring analysis and materials not provided by EnWave
10 kW REV
Confidential Proprietary
Anchoring points for the main chamber (detail)
Anchoring analysis and materials not provided by EnWave
Main chamber side view
Anchoring points for the pump skid
Holes compatible with ½” threaded bars/anchors
Anchoring analysis and materials not provided by EnWave
10 kW REV
Confidential Proprietary
Anchoring points for the pump skid (detail)
Anchoring analysis and materials not provided by EnWave
Pump skid side view
Anchoring points for the electrical cabinet
Holes compatible with ½” threaded bars/anchors
Anchoring analysis and materials not provided by EnWave
10 kW REV
Expected Packing list for Shipping
• This is a tentative list that will be confirmed 2 weeks before shipping.
• A FCL 20’ container can be used to ship this unit.
10 kW REV
Tentative Installation Plan
Assuming that all utilities are readily available and there is sufficient product for testing, the installation/commissioning process of the REV dryer takes approx. 3 to 4 days. Please find below an estimate of the expected schedule and required materials:
• Day 1 (and maybe day 2): Our field engineer works with your team on the installation of the REV dryer. During day 1 and day 2 US Army CCDC SC needs to provide the following resources:
• All utilities described in page 8 of this document including sufficient product for testing.
• Electrician available during day 1 to connect the REV dryer to the electrical mains.
• Technician available during day 1 to connect the pump skid of the REV dryer to the cooling water supply (e.g. chiller), and the compressed air supply.
• IT personnel available during day 1 to connect the REV dryer to the Internet infrastructure.
• One technical assistant should be available during days 1 and 2 to help our engineer. The assistant should have access to a basic mechanical/electrical toolkit. We recommend that the person assisting our engineer is the person that will oversee service and maintenance for the dryer (maintenance personnel).
• A +5,000 lb. forklift, gantry or lifting table.
• A +5,000 lb. pallet jack.
• Day 2: Our field engineer and our process scientist will test the functionalities of the REV dryer to confirm that everything is operating according to specifications. If the testing of the machine results ideal, our process scientist could start training your team on day 2. During day 2 and day 3 US Army CCDC SC needs to provide the following resources:
• Sufficient product to test.
• Top loading scale.
• Small coffee grinder.
• Moisture analyzer.
• Water activity meter.
• IR thermometer.
• Day 3 (and if necessary day 4): Our process scientist trains your team and confirms commissioning of the REV dryer.
10 kW REV
| Slide Number 1 |
| Slide Number 2 |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
| Slide Number 12 |
| Slide Number 13 |
| Slide Number 14 |
| Slide Number 15 |
| Slide Number 16 |
| Slide Number 17 |
| Slide Number 18 |
| Slide Number 19 |
| Slide Number 20 |
| Slide Number 21 |
| Slide Number 22 |
| Slide Number 23 |
| Slide Number 24 |
| Slide Number 25 |
| Slide Number 26 |
File details come from the government source that posted it. Updated .