20-R-88JA Synopsis AB-18008-8JA.pdf

PDF 91 KB Posted

Attached to
A-E HVAC Design Services Federal contract opportunity
Solicitation number
W911S2-20-R-88JA
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum

About this file

This notice solicits Architect and Engineering design services for HVAC upgrades at the Child Development Center at Fort Drum, New York. The Mission and Installation Contracting Command at Fort Drum will award a single firm-fixed price contract for design services with a 130-day period of performance, to be followed by an estimated 210-day construction period. The requirement is reserved exclusively for Women-Owned Small Businesses. Interested parties must submit Standard Form 330 qualifications by August 6th, with evaluation criteria focusing on experience with military construction projects, staff qualifications, and past performance. The selected firm may receive a request for proposal within 10 business days of qualification evaluation.

View the file

Other files for this federal contract opportunity

Other files attached to A-E HVAC Design Services, newest first.
File Type Posted
RFI Response 1.pdf PDF
20-R-88JA Synopsis AB-18008-8JA(Amendment 1).pdf PDF
SF330-16f.pdf PDF
20-R-88JA PWS AB-18000-8JA.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Mission and Installation Contracting Command (MICC) – Fort Drum, NY is issuing this notice for the procurement of Architect and Engineering (A-E) Design Services for the Child Development Center (CDC) HVAC Fort Drum, NY.

This notice constitutes a special situation in accordance with FAR 5.205(d). Firms wishing to be considered for evaluation in response to this notice shall submit a SF 330, Architect-Engineer Qualifications, as detailed below section, Submission Requirements.

This procurement is being conducted in accordance with the Brooks Act, as implemented in Federal Acquisition Regulation (FAR) Subpart 36.6. The North American Industry Classification System (NAICS) code for this action is 541330, Engineering Services, with a Size Standard of $16.5M. The service code is C1QA, Architect and Engineering- Construction: Restoration of Real Property (Public or Private). The requirement is being set-aside 100% for Women Owned Small Business (WOSB) concerns in accordance with FAR 19.502-2. Interested firms must be registered in the System for Award Management (SAM), https://www.sam.gov.

Registration must be complete prior to the end date of this notice.

CONTRACT INFORMATION: The Government intends to award no more than one (1) firm-fixed price contract. The magnitude of the construction project is between $1,000,000 and $5,000,000. The contract will have a design period of performance that shall not exceed 130 calendar days from contract award. The estimated construction period of performance shall not exceed 210 days from Notice to Proceed.

PROJECT INFORMATION: A-E services, as defined in in 40 USC 1101 and FAR 2.101, to support CDC HVAC design at Fort Drum. The general scope of work is detailed in the PWS attached to this notice.

All A-E firms responding to this notice are advised of the restrictions in FAR 36.209 which prohibits a contract for a construction project being awarded to the firm that designed the project or that firm’s subsidiaries or affiliates. Additionally, FAR Part 9.5, Organizational and Consultant Conflicts of Interest, prohibits an A-E firm being subcontracted to provide services to a Construction vendor on a project where the A-E firm previously completed work.

SELECTION CRITERIA: The source selection factors for this procurement are listed below in descending order of importance. Factors 1 through 5 are primary. Factors 6 and 7 are listed in descending order of importance and are secondary and will only be used as a tie-breaker among technically equal firms. Primary factors will be assigned a rating as follows:

Rating Description Outstanding Proposal meets requirements and indicates an exceptional approach and understanding of the requirements. Strengths far outweigh any weaknesses.

Risk of unsuccessful performance is very low.

Good Proposal meets requirements and indicates a thorough approach and understanding of the requirements.

Proposal contains strengths which outweigh any weaknesses. Risk of unsuccessful performance is low.

Acceptable Proposal meets requirements and indicates an adequate approach and understanding of the requirements.

Strengths and weaknesses are offsetting or will have little or no impact on contract performance. Risk of unsuccessful performance is no worse than moderate.

Marginal Proposal does not clearly meet requirements and has not demonstrated an adequate approach and understanding of the requirements. The proposal has one or more weaknesses which are not offset by strengths. Risk of unsuccessful performance is high.

Unacceptable Proposal does not meet requirements and contains one or more deficiencies. Proposal is not awardable.

Ratings are based on the risk to the Government that the Offeror will successfully perform that evaluated factor. An overall rating will also be applied to the proposal submission using the same rating scale. Proposals failing to respond or provide complete information for each factor as required by this notice will be determined non-responsive and will be removed from further consideration.

NOTE: For purposes of responses to this notice, a stand-alone contract or task order is considered one project. Listing differing activities performed under a stand-alone contract or task order will not be considered multiple projects. Conversely, combining activities performed under separate contracts or task orders to produce a single project will not be considered. Projects in which A-E Service is not complete will not be evaluated.

Factor 1. Professional Qualifications (SF330, Part I, Sections E and G)

Part A - Resumes of Key Personnel (Section E, Blocks 12 - 18): Firms must have, either in-house or through consultants or subcontractors, the disciplines listed below. To demonstrate qualifications, resumes for persons filling these disciplines are to be provided in Section E. Each resume shall not exceed three page in length. In Block 13, the role listed must use the exact same discipline nomenclature as listed below. If an individual will serve in more than one role, then all disciplines shall be clearly indicated in Block 13. The format of Section E is not to be altered. Additionally, all Key Personnel must be shown on the organizational chart in Section D.

The firm agrees to assign to the contract those persons whose resumes are submitted.

If assigned personnel become unavailable for work under the contract for a continuous period exceeding 30 working days, or are expected to devote substantially less effort to the work than indicated in the proposal, the firm shall propose a substitution of such personnel. All proposed personnel substitutions shall be submitted, in writing, to the Contracting Officer at least 15 calendar days prior to the proposed substitution. All proposed substitutes shall have qualifications equal to or higher than the qualifications of the individual being replaced.

Primary disciplines:

(1) Project Manager – Demonstrate experience using a Critical Path Method (CPM)

(2) Mechanical Engineer - Professional Engineer, provide licensure/certification number and date

(3) Electrical Engineer - Professional Engineer, provide licensure/certification number and date

(4) Fire Protection Engineer - Professional Fire Protection Engineer, provide licensure/certification number and date; demonstrate two years design experience with sprinkler fire protection systems; demonstrate four years of design experience with current nationally recognized codes such as National Fire Protection Agency (NFPA), with special emphasis on NFPA 101 Life Safety

Secondary disciplines:

(1) Architect - Registered Architect or Interior Designer with NCIDQ certification, provide licensure/certification number and date;

(2) Cost Estimator - Certified AACE, ICEC, PCEA, or equivalent; provide licensure/certification number and date; Resumes are required for the firm's and/or consultant's cost engineering or estimating specialist(s) for the each of the following disciplines: architectural, structural, civil, mechanical, and electrical; A single resume may demonstrate experience in one or more disciplines, however, competence and experience for each assigned discipline must be clearly demonstrated

(3) Specification and Technical Writing

(4) Construction Quality Assurance

(5) Drawings of Existing Structures

(6) Drafting/Computer Aided Design and Drafting

(7) Provide scanned digital PDF copies of existing construction document

(8) Provide scanned digital DGN or DWG copies of existing construction drawings

Part B - Relevant Projects (Section E, Block 19): All Key Personnel are required to have a minimum of five (5) years of project experience in their discipline demonstrated by projects with scope, magnitude, and complexity comparable to this notice. The definition of a project is as noted in ‘Selection Criteria' above. Relevant projects are those that reflect experience performing the respective discipline. Relevant Project information should be brief and highlight specific roles and tasks performed by the Key Personnel, Project Type, Scope, and Costs. No more than five projects should be listed for each resume, and each project listed must have been completed within five (5) years of publication of this announcement. (Note: The projects provided for this factor may also be used to address Factor 2).

The evaluation of Factor 1 will take into consideration the education and current registration, licensure or certification(s), as applicable, of each person named for each discipline and that person's longevity with the firm named in Block 15. It will also take into consideration the person's relevant project experience provided in Block 19. More weight will be given to experience with full-design type projects, on military installations, that are of scope, magnitude, and complexity similar to that described above in the paragraph titled Project Information. This factor may be assessed Strengths or Weaknesses, as appropriate. Only the Key Personnel disciplines requested in this notice will be evaluated.

Factor 2. Specialized Experience and Technical Competence (SF330, Part I, Sections F and G)

Demonstrate specialized experience and technical competence for the design of facilities and infrastructure for construction which meets the definition of A-E Services as defined in 40 U.S.C. 1101 and FAR 2.101. This factor considers specialized experience and technical competence to support construction activities similar to those described above in the paragraph titled Project Information.

Submit up to ten (10) projects that best illustrate the proposed team's qualifications for award of a contract. Please note that the projects provided for Factor 1 may also be used to address this factor. The definition of a project is noted in ‘Selection Criteria' above. For each project use only one page and note the contract or task order number, as applicable.

All projects must have been completed within five (5) years of publication of this announcement. At least five (5) of the projects presented must show that the respondent (the firm submitting the SF330 as the prime contractor), performed the majority (>50%) of the work on the project, either as a prime contractor or subcontractor. If a proposed subcontractor also worked on the project, state the percentage of work it performed. Clearly identify the Project Type and the Firm's role on the project, for example, Full Design, Design Build RFP Developer, or Contractor's Designer of Record. In Block 24, "cost" is the total value of the project, not simply the value of the work performed by the Offeror and/or any proposed subcontractor. To demonstrate quality of past performance, for each project the Firm must provide a Contractor Performance Assessment Report System (CPARS). Quality of past performance information for key projects may be placed in Part II. The Government reserves the right to review any official performance evaluation system of records to inform its source selection decision. When completing Section G, in Block 26, along with the name of key personnel, include the firm with whom the person is or was associated at the time the project was performed.

Firms submitting as Joint Ventures (JV) must follow the same procedures as any other respondent with the following exception: If the JV cannot provide at least five (5) projects that demonstrate performance by the JV of 50% or more of a project, either as a prime contractor or subcontractor, the JV may provide projects performed by any partner of the offering JV that reflects performance of 50% or more of a project, either as a prime contractor or subcontractor.

Of the projects submitted as prescribed above, relevant projects are those that reflect the specialized experience and technical competence of the respondent and/or proposed subcontractor, as prime contractors or subcontractors, performing services similar to those described above in the paragraph titled Project Information. More weight will be given to project designs that are full-design type projects, on military installations, and that are of scope, magnitude, and complexity similar to that described above in the paragraph titled Project Information.

Factor 3. Capacity to Accomplish the Work (SF330, Part I, Section D and H)

Demonstrate capacity, experience, and an effective organizational structure. The project team must demonstrate capability to accomplish up to an estimated three (3) task orders simultaneously in a 180-day period. The evaluation will include a review of project specific descriptions to determine the extent to which the A-E firm has proven their ability to work on multiple projects, large scale projects, complex projects, and provide an adequate number of personnel in key disciplines.

In addition, Section D of SF 330 should include an organization chart. The SF 330 shall clearly indicate the primary office where the work will be performed, and the staff at this office.

Factor 4. Past Performance (SF330, Part I, Section H)

Provide evidence of recent projects performed by the prime and key subcontractors demonstrating experience. Relevant experience is experience with full-design type projects, on military installations, that are of scope, magnitude, and complexity similar to that described above in the paragraph titled Project Information. Recent experience is experience on projects that have been completed within five (5) years of publication of this announcement.

Demonstrate in narrative (or other format) a history of customer satisfaction with the respondent’s quality of work, cost control and scheduling. Past Performance history is not to be limited to information presented in Factor 2. The Government may use data provided in the Contractor Past Performance Reporting System (CPARS), Federal Awardee Performance and Integrity Information System (FAPIIS), or other similar project evaluation systems in conducting an assessment of Government confidence in the firm’s past performance. Customer excerpts or quotes from prior evaluations for the purposes of substantiating the narrative should not be provided. Indication of favorable performance ratings, awards, and repeat clientele in Section H of SF 330 is recommended.

Factor 5. Location in the General Geographical area of the Project and Knowledge of the Locality (SF330, Part I, Section H)

Demonstrate a familiarity with Fort Drum, NY. This includes items such as geological features, climatic conditions, and unique or unusual construction methods.

Factor 6. Geographic Proximity

The firm’s principal office in relation to distance (miles) from Fort Drum, NY. This factor is secondary and will only be evaluated as a tie-breaker among technically equal firms.

Factor 7. Volume of DOD Contract Awards (SF330, Part I, Section H)

Provide the volume of work awarded by DOD agencies during the previous 12 months.

Volume of work shall be demonstrated in a table format and be categorized by contract/task order, project award and completion dates, and dollar amount. This factor is secondary and will only be evaluated as a tie-breaker among technically equal firms.

SUBMISSION REQUIREMENTS: Interested A-E firms with the capabilities to perform this work shall submit a Standard Form (SF) 330, Architect-Engineer Qualifications, Part I and Part II. All information must be submitted on the SF 330, and shall not include other formats referencing the SF330 in lieu of submitting the SF 330. A fully completed Part I and Part II sections of the SF 330 must be submitted. An incomplete SF 330 will not be considered for evaluation.

Submissions shall be in electronic format (Microsoft Word or searchable Adobe Acrobat Portable Document File) only. Email or CD/DVD attachments are acceptable. Email submissions should be sent to Mr. A. Milan Sanchez at alfredo.m.sanchez.civ@mail.mil.

CD/DVD submissions should be sent to Mr. A. Milan Sanchez at the address identified at the end of this notice.

All fonts shall be at least 12 point or smaller in Arial (not Arial Narrow) to include text, tables and figures. Pages shall be 8-1/2 inches by 11 inches. The Organization Chart required in Part I, Section D, and the Matrix required by Part I, Section G, may be presented on a sheet up to 11 inches by 17 inches. Submissions are to be organized as follows:

Part I of the SF330 shall not exceed 100 pages, front side only, excluding tabs, separators and blank sheets, and shall be organized as follows:

Tab A - SF330, Part I, Sections A, B, C and D.

Tab B - SF330, Part I, Section E.

Tab C - SF330, Part I, Section F, CPARS.

Tab D - SF330, Part I, Section G.

Tab E - SF330, Part I, Sections H and I.

Part II of the SF330 shall have no limitation. A SF330, Part II submission, is required for each branch office of the firm and any subcontractor that will perform a key role under the contract. Part II shall be organized as follows:

Tab F - SF330, Part II.

Tab G - Joint Venture Agreement (if applicable).

Tab H - Additional Information (if applicable).

All respondents must be registered in the System for Award Management (SAM). For instructions on registering with the SAM, go to https://www.sam.gov/portal/public/SAM/.

NOTE: This is NOT a Request for Proposal. Respondents are hereby notified that, if designated as one of the most highly qualified firms, the response time for the issued Request for Proposal (RFP) is anticipated to be 10 business days from the date of RFP issue.

SUBMISSIONS MUST BE RECEIVED NO LATER THAN August 6, 2020, 3:00 p.m., E.S.T. Submissions received after this time will be viewed as late and not considered.

ALL QUESTIONS SHALL BE SUBMITTED NO LATER THAN July 22, 2020, 3:00 p.m., E.S.T. to Mr. A. Milan Sanchez at alfredo.m.sanchez.civ@mail.mil. Questions submitted after this time may not be considered for response. All timely submitted questions and/or comments will be addressed through subsequent amendments posted to this notice. No other means of communication (telephone, fax, etc.) will be accepted.

Contracting Office Address:

P31 Quartermaster Road Fort Road, NY 13602

File details come from the government source that posted it. Updated .