2-WWTP Influent Pump Improvements Project Drawings 4603.017.pdf
PDF 14 MB Posted
- Attached to
- WWTP Influent Pump Improvements
- Solicitation number
- Not on record
- Issued by
- Schuylkill County, Pennsylvania
About this file
WWTP Influent Pump Improvements Project Drawings Summary
This file comprises the project drawings and technical specifications for the Porter-Tower Joint Municipal Authority WWTP Influent Pump Improvements project located at 860 W. Grand Ave, Tower City, Pennsylvania 17980. The project consists of two separate contracts: Contract No. 01 (General/Process Mechanical) and Contract No. 02 (Electrical). The primary scope of work includes the installation of a new 15 horsepower jockey influent pump with variable frequency drive (VFD) in the Operations building, modifications to existing piping systems, upgrades to the existing WWTP control panel for VFD integration and new process instrumentation, and SCADA system integration to be performed by the owner's integrator, Martz Technologies, Inc. The project requires replacement of existing influent pumps with Weil vertical sewage pumps and includes demolition activities, structural modifications, and comprehensive electrical installations. Bids are due electronically via the PennBid Program by Monday, February 9, 2026 at 1:00 pm local time. A pre-bid conference is scheduled for Monday, January 26, 2026 at 11:00 am at the project site. The wastewater treatment plant must remain fully operational throughout all construction activities, and all underground utilities must be located prior to earth-moving activities in compliance with Pennsylvania Act No. 287.
The drawings include general project notes, aerial site plans, operations building demolition and construction plans, process and instrumentation diagrams, and detailed electrical plans spanning multiple levels of the facility. Key specifications include the installation of an Altivar 630 Process AC Drive rated at 15 horsepower within Motor Control Center 100, magnetic flow meter installation with remote-mounted indicators and transmitters, level sensing equipment with float switches and pressure transducers, and comprehensive conduit and wiring systems routed throughout the facility. The electrical work requires new NEMA 12/4X stainless steel disconnect switches, conduit installation with minimum three-foot cover depth for underground electric conduit, and compliance with the 2017 National Electrical Code. All work must follow prevailing wage requirements as determined by the Pennsylvania Department of Labor and Industry, and contractors must maintain facility access while restoring all property to original condition upon project completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-WWTP Influent Pump Improvements Project Manual 4603.017.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL PROJECT NOTESPORTER TOWER JOINT MUNICIPAL AUTHORITY
WWTP INFLUENT PUMP IMPROVEMENTS
CONTRACT NO. 01 GENERAL / PROCESS MECHANICAL
CONTRACT NO. 02 ELECTRICAL
G
EN
ER
AL
P R
O
JE
C T
N O
TE
S, D R
AW
IN
G
IN
D
EX
, D R
AW
IN
G C
O N
VE
N
TI
O
N S
AN
D
M
AP
S G
EN
ER
AL
DRAWING CONVENTIONS
A. DESIGN DRAWINGS MUST BE WORKED IN CONJUNCTION WITH THE
PROJECT MANUAL AND SPECIFICATIONS.
B. ALL UNDERGROUND UTILITIES SHALL BE LOCATED BY THE
CONTRACTOR PRIOR TO ANY EARTH MOVING ACTIVITIES PURSUANT TO
PA ACT NO. 287. UNDERGROUND UTILITIES MUST BE VERIFIED BY
CONTACTING THE “ONE CALL SYSTEM” AT 1-800-242-1776. THE SERIAL
NUMBER(S) INDICATED ON THIS COVER SHEET AND THE ONE CALL
CHART WAS IN RESPONSE TO THE ENGINEERS' REQUEST DURING
DESIGN AND IS PROVIDED FOR REFERENCE ONLY. CONTRACTOR SHALL
ALSO PROVIDE THIRD PARTY LINE LOCATION SERVICE IN ACCORDANCE
WITH SPECIFICATIONS.
C. ELECTRIC CONDUIT SHALL BE INSTALLED WITH A MINIMUM COVER OF
THREE FEET (3”-0”) UNLESS NOTED OTHERWISE.
D. CONTRACTOR SHALL MAINTAIN FACILITY ACCESS AT ALL TIMES AND
RESTORE ALL PROPERTY TO ORIGINAL CONDITION.
E. WASTEWATER TREATMENT PLANT SHALL REMAIN FULLY OPERATIONAL
DURING CONSTRUCTION ACTIVITIES.
SCALE:2 NONE
VICINITY MAP
PROJECT SITE
00 2000' 4000'
SCALE:1 1" = 2000'
LOCATION / TOPOGRAPHICAL MAP
SECTION INDICATOR
DETAIL INDICATOR
ELEVATION INDICATOR1
X-201
A X-301
A X-301
X-501
SCALE:1 1" = 1'-0"
DRAWING TITLE
DRAWING NUMBER
SECTION LETTER
DRAWING NUMBER
ELEVATION LETTER
IDENTIFICATION NUMBER/LETTER
DRAWING TITLE
A
SHEET KEYNOTE SYMBOL
DEMOLITION KEYNOTE
SYMBOL
PHOTOGRAPH INDICATOR
PHOTOGRAPH
IDENTIFICATION
DRAWING NUMBER
DETAIL NUMBER
A
TEXT
INDICATES EXIST
CONDITIONS/FEATURES
INDICATES NEW
WORK/FEATURES
DENOTES REFERENCE TO ENLARGED
PLANS WITH DRAWING NUMBER
INDICATED
X
XXX
REFERENCE DRAWINGS
1. EXISTING WASTEWATER TREATMENT PLANT DRAWINGS REFERENCE
LARSON DESIGN GROUP "WATER TREATMENT PLANT UPGRADE"
PROJECT # 5941-018 DATED NOVEMBER 2012.
REFERENCE: USGS 7.5 MINUTE SERIES (TOPOGRAPHIC MAP) TOWER CITY, PENNSYLVANIA
JANUARY 16, 2026
ISSUED FOR
BIDDING
PLANT ADDRESS:
860 W. GRAND AVE.
TOWER CITY, PA. 17980
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\G-001.dwgLa st
E di te d by : p m cc ar ty
G-001
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
PTJMA WWTP
LAT: 40° 35' 01.8"N
LONG: -76° 34' 50.7"W
DRAWING INDEX CONTRACT NO. 01
DWG. NO. DRAWING DESCRIPTION/TITLE
GENERAL
G-001 GENERAL PROJECT NOTES, DRAWING INDEX, DRAWING CONVENTIONS AND MAPS
G-002 DRAWING LEGENDS, SYMBOLS AND ABBREVIATIONS
G-101 AERIAL SITE PLAN - EXISTING CONDITIONS
G-601 PARTIAL FORWARD FLOW PROCESS AND INSTRUMENTATION DIAGRAM
DEMOLITION
GED-401 OPERATIONS BUILDING DEMOLITION PLANS, KEYED NOTES AND PHOTOGRAPHS
PROCESS MECHANICAL
D-101 OPERATIONS BUILDING INTERMEDIATE AND LOWER LEVEL PLANS AND NOTES
D-301 OPERATIONS BUILDING SECTIONS
D-501 INSTRUMENTATION DETAILS
DRAWING INDEX CONTRACT NO. 02
DWG. NO. DRAWING DESCRIPTION/TITLE
GENERAL
G-001 GENERAL PROJECT NOTES, DRAWING INDEX, DRAWING CONVENTIONS AND MAPS
G-002 DRAWING LEGENDS, SYMBOLS AND ABBREVIATIONS
G-101 AERIAL SITE PLAN - EXISTING CONDITIONS
G-601 PARTIAL FORWARD FLOW PROCESS AND INSTRUMENTATION DIAGRAM
DEMOLITION
GED-401 OPERATIONS BUILDING DEMOLITION PLANS, KEYED NOTES AND PHOTOGRAPHS
ELECTRICAL
E-101 OPERATIONS BUILDING UPPER LEVEL PLAN AND NOTES
E-102 OPERATIONS BUILDING INTERMEDIATE AND LOWER LEVEL PLANS AND NOTES
E-501 ELECTRICAL LEGEND
E-502 ELECTRICAL DETAILS
E-601 PROPOSED MCC ONE LINE
356.00
360 PROPOSED GRADE (MAJOR)
PROPOSED STORM DRAIN
PROPOSED WATER LATERAL
PROPOSED PAVED SURFACE
ROCK CONSTRUCTION ENTRANCE
PROPOSED CHAIN LINK FENCE
PROPOSED INLET
PROPOSED STORM DRAIN MANHOLE
PROPOSED YARD HYDRANT
PROPOSED GATE VALVE
PROPOSED PLUG VALVE
PROPOSED MECHANICAL JOINT FITTING
LIMIT OF DISTURBANCE
B-5
EXISTING FACILITY TO BE REMOVED
EXISTING FACILITY TO BE MODIFIED
NEW BUILDING FACILITIES
SUPER SILT FILTER FABRIC FENCE
PROPOSED MACADAM ACCESS
ROAD/ STONE DRIVEWAY
EROSION CONTROL BLANKET STEEP SLOPES
PROPOSED WATER MAINW W
PROPOSED HYDRANT
RIP RAP OUTLET PROTECTION
SILT SACK INLET PROTECTION
PROPOSED CURB STOP
PROPOSED WATER METER & METER BOXWMB
CS
WAS-SC WAS-SC PROPOSED WASTE ACTIVATED SLUDGE / SCUM LINE
PROPOSED SANITARY MAINSAN SAN
FILTER FABRIC FENCE - 30"
FILTER FABRIC FENCE - 18"
PROPOSED ELECTRIC
PROPOSED SANITARY MANHOLE
356 PROPOSED GRADE (MINOR)
EROSION CONTROL SWALE MATTING
NPDES PERMIT BOUNDARY
CB
YH
D
S
TEXT PROPOSED TEXT
PROPOSED SANITARY FORCE MAINFM FM
MATCHLINE
MATCH LINE REFER TO DWG C-101
TRENCH PLUG
PROPOSED UTILITY WATER LINE
PROPOSED WASTEWATER LINE
RAS RAS PROPOSED RETURN ACTIVATED SLUDGE LINE
WAS WAS PROPOSED WASTE ACTIVATED SLUDGE LINE
PROPOSED SLUDGE LINE
PROPOSED SCUM LINE
PROPOSED DRAIN LINE
PROPOSED CLEAN OUTCO
PROPOSED AIR LINE
SwD Bh
SwD Bh
18" COMPOST FILTER SOCK
24" COMPOST FILTER SOCK
32" COMPOST FILTER SOCK
12" COMPOST FILTER SOCK
IN
ST
R U
M
EN
T
SY
M
BO
LS
MOUNTED BEHIND PANEL DOOR
ALARM LIGHT
NOT ACCESSIBLE TO OPERATOR
ACCESSIBLE TO OPERATOR
AUXILLIARY LOCATION
NOT ACCESSIBLE TO OPERATOR
ACCESSIBLE TO OPERATOR
COMPLEX OR UNDEFINED INTERLOCKI
D
IS
TR
IB
U
TE
D C
O N
TR
O
L
SH
AR
ED
IN
ST
R
U M
EN
TS
SY
M
BO
LS
PR
O
G R
AM
M
AB
LE
C O
N
TR
O
LL
ER
LO
C K
IN
TE
R
SY
M
BO
LS
SY
M
BO
LS
O R
MOUNTED LOCALLY
MOUNTED ON FACE OF PANEL
INDICATE
SCAN
LOW/LIGHT
CONTROL STATION
ORIFICE
SWITCH
RECORD/PRINT
TRANSMIT
INTEGRATE/TOTALIZE
VALVE
RELAY
MULTIFUNCTION
DRIVE/ACTUATE
MIDDLE
COMPUTING OR SIGNAL CONVERTING
SPEED/FREQUENCY
TEMPERATURE/TORQUE
POSITION
VISCOSITY/VIBRATION
MULTIVARIABLE
EVENT, STATE PRESENCE
W
X
Z
Y
WEIGHT
STATUS
R
S
T
V
U
REMOTE
QUANTITY
TURBIDITY
PRESSURE / VACUUM
MOISTURE/MALFUNCTIONM
O
P
N
Q
I
K
L
J
CURRENT
POWER
TIME
LEVEL
INSTRUMENTATION DEVICE SCHEDULE
ALARM
CONTROL
PRIMARY ELEMENT
HIGH
GLASS/GAUGE
MEASURED
VOLTAGE
DENSITY DIFFERENTIAL
CHLORINE
ANALYSIS
VARIABLE
FLOW RATE
D
E
G
H
F
HAND
A
B
C
BURNER
DELAY
FIRST LETTER
DISPLAY OR
OUTPUT FUNCTION
SUCCEEDING LETTERS
CIVIL LEGEND ABBREVIATIONS LEGEND
REFRIGERATOR
RESILIENT BASE
REINFORCE(D), REINFORCING
RISER, RADIUS
PAPER TOWEL DISPENSER
POINT, PRESSURE TREATED
PAPER TOWEL RECEPTACLE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PLUMBING CONTRACTOR
SOLID SURFACE MATERIAL
SPECIAL WALL COVERING
RAIN WATER CONDUCTOR
ROUGH OPENING, ROOF OPENING
SOLID POLYMER FABRICATIONS
SQUARE FOOT
SPECIFICATION
TOILET PARTITION
VENT THROUGH ROOF
VINYL COMPOSITION TILE
VINYL COVE BASE
VENEER PLASTER, VAPOR PROOF
UNLESS NOTED OTHERWISE
TOILET PAPER DISPENSER
TOP OF SLAB
TOP OF STEEL
TOP OF WALL
TOP OF MASONRY
FINISHED
ABOVE
PLUMBING
MOUNTING
ESTIMATE
EQUIPMENT
EXHAUST
EXISTING
EQUAL
EACH WAY
FIRE ALARM
FLOOR DRAIN
EXTERIOR
EXPANSION
ELECTRIC WATER COOLER
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FINISHED BY OTHERS
FINISH FLOOR ELEVATION
FIRE HOSE CABINET
CONTRACTOR INSTALLED
NON-FUSED DISCONNECT SWITCH
OPPOSITE
NUMBER / NORMALLY OPEN
NOMINAL
NOT IN CONTRACT
NOT TO SCALE
NOT APPLICABLE
OPENING
OVERHEAD
OVERALL / OUTSIDE AIR
OUTSIDE DIAMETER
OWNER FURNISHED
ON CENTER
WITHOUT
WOOD
WITH
UNDERCUT
VERTICAL
TYPICAL
AMERICAN STANDARD TESTING MATERIAL
CEILING
CLOSET
COLUMN
CONCRETE
CONSTRUCTION
CORRIDOR
COURSE(S)
CURB STOP, CORPORATION STOP
CARPET
CONTRACTOR
CONTINUOUS
CLEAN ROOM WALL PANEL
CONCRETE MASONRY UNIT
DOWN SPOUT
DRAWING
DOOR, DRAIN
DIAMETER
DIMENSION
EMERGENCY
ELECTRIC(AL)
ELEVATION
EACH
DRINKING FOUNTAIN
EXPANSION JOINT
EXPANSION JOINT
ELECTRICAL CONTRACTOR
DETAIL
ADJUSTABLE
ALTERNATE
ACOUSTIC
ABANDON
ASPHALT
APPROXIMATE
ALUMINUM
ACOUSTIC TILE CEILING
ABOVE FINISHED FLOOR
ARCHITECTURAL WOOD INSTITUTE
BOTTOM FOUNDATION ELEVATION
ARCHITECTURAL
BEAM
BRICK
BASEMENT
BOTTOM
BUILDING
BLOCKING
BITUMINOUS
BUILT UP ROOF
CENTERLINE
CATCH BASIN
CONTROL JOINT
CABINET
CENTER TO CENTER
AIR CONDITIONING
MECHANICAL/ELECTRICAL/PLUMBING
LOW POINT, LIGHTING PANEL
MEDIUM DENSITY OVERLAY
JANITOR, JANITOR'S CLOSET
LOUVER
MAXIMUM
METAL
MECHANICAL
MINIMUM
MECHANICAL JOINT
MOUNT(ED)
MISCELLANEOUS
MANUFACTURER
MANUFACTURING
INTERIOR
INSIDE DIAMETER
INFORMATION
ISOLATION JOINT
JOINT
LENGTH, LONG
LAMINATE(D)
LINEAR FOOT
HVAC CONTRACTOR
INSULATE, INSULATION
SUSPENDED
SYSTEM
TREAD, TOP
THICK(NESS)
TERRAZZO
TELEPHONE
TEMPERED
STEEL
STANDARD
STRUCTURAL
SHEET VINYL
STORAGE
SECTION
SIMILAR
SQUARE
SHOWER
ROOM
RUBBER TILE
SANITARY
SCHEDULE
GROUND
HEADER
HANDICAP(PED)
HOLLOW METAL
HARDWARE
HIGH
HEIGHT
HIGH POINT / HORSEPOWER
HANDRAIL
HORIZONTAL
GYPSUM WALLBOARD
HEATING, VENTILATING &
FLOOR
FIXTURE
FACE OF FINISH
FOUNDATION
FOOTING
GAUGE
FIREPROOF(ING)
GALVANIZED
GRAB BAR
FACE OF STUDS
GENERAL CONTRACTOR
FACE OF CONCRETE
FACE OF MASONRY
RETURN
REFERENCE
REQUIRED
REVISION
RESILIENT
RADIUS
QUANTITY
QUARRY TILE
RETURN AIR
ROOF DRAIN
PAIR
PARTITION
PAINTED
PLATE
PLASTER
PLACES
CLEAN-OUT
PREMOLDED JOINT FILLER
LEVEL / LAMINATED VENEER LUMBER
DEPARTMENT
BALANCING VALVE
CUBIC FEET PER MINUTE
AIR CONDITIONING CONDENSATE
CHLORINATED PVC PIPE
DOMESTIC COLD WATER
DOWN
ENTERING AIR TEMPERATURE
ENTERING DRY BULB
EXTERNAL STATIC PRESSURE
ENTERING WET BULB
ENTERING WATER TEMPERATURE
INVERT
JUNCTION BOX
KILOWATT
LEAVING AIR TEMPERATURE
MECHANICAL CONTRACTOR
NORMALLY CLOSED
PANEL
PRESSURE REGULATING VALVE
POLYVINYL CHLORIDE
REVOLUTIONS PER MINUTE
SUPPLY AIR
UNIT HEATER
VARIABLE SPEED DRIVE
VARIABLE FREQUENCY DRIVE
AIR HANDLING UNIT
ACCESS PANEL
FLEXIBLE CONNECTOR
FIN
PLBG
ABV
MTG
TOM
EST
FHC
FEE
FEC
FBO
EXP
FE
FD
FA
EXT
EQUIP
EXIST
EWC
EXH
EQ
EW
OPP
OFCI
OPNG
OC
OD
OA
OH
NFDS
NA
NO
NOM
NTS
NIC
W/O
WD
W/
TOW, TW
TYP
TOS
TPTN
VERT
VTR
UNO
VCT
VCB
UC
VP
TSL
TP
CLG
DET
EA
EMER
ELEC
EJ
EC
EL/ELEV
EXP JT
DIA,Ø
DWG
DR
DS
DIM
DF
CONT
CORR
CRWP
CPT
CRS
CS
CONTR
CONC
COL
CLO
CMU
CONST
CAB
BUR
CJ
LC
CC
CB
BRK
BSMT
BLDG
BLKG
BOT, BTM
BM
BIT
ALUM
ARCH
ASPH
ASTM
BFE
AWI
APPROX
ACT
ADJ
AFF
ALT
ATC
ABDN
LVR
MFG
MISC
MT(D)
MJ
MIN
MANUF.
MAX
MECH
MDO
MEP
MET
JAN
L
LAM
LF
LP
JT
INSUL
IJ
INFO
HC
INT
ID
SSM
STOR
SWC
STR
STD
TMPD
THK
TER
SYS
SUSP
T
TEL
STL
SV
SAN
SCH
RWC
SPEC
SHR
SPF
SECT
SIM
SQ
SF
RO
RT
RM
HORIZ
HVAC
HR
HT
H
HP
GWB
HDWR
GND
H/C
HM
HDR
FOS
GALV
FTG
FP
GC
GB
GA
FIXT
FOF
FOM
FOC
FDN
FLR
QTY
RAD
REFR.
REQD
REINF
REF
REV
RET
RES
RB
RD
QT
RA
R
PNT(D)
PLCS
PTR
PTN
PTD
PSF
PR
PT
PSI
P
PL
PC
CO
PMJF
LVL
DEPT
AHU
AP
FLEX
BV
CFM
COND
CPVC
CW
DN
EAT
DB
ESP
EWT
EWB
INV
JB
KW
LAT
MC
NC
PNL
PRV
PVC
RPM
SA
UH
VSD
VFD
MACADAMMAC
WASTE WATERWW
GALLONGAL
PLYWOODPLY
LEVEL SENSORLS
LEVEL ELEMENTLE
LEVEL TRANSDUCER / TRANSMITERLT
MASONRY OPENINGMO
DUCTILE IRON PIPEDI, DIP
CAST IRON PIPECI, CIP
UNNAMED TRIBUTARYUNT
MOTOR CONTROL PANELMCP
MICRO SCREEN CONTROL PANELMSCP
HAND SWITCHHS
FLOW INDICATING TRANSMITTERFIT
ANALYSIS INDICATING TRANSMITTERAIT
PLUG VALVEPV
STOP GATESG
D R
AW
IN
G L
EG
EN
D S, S
YM
BO
LS
A N
D A
BB
R
EV
IA
TI
O
N S
G
EN
ER
AL
M
S
WASTEWATER P&ID LEGEND
8"
GATE VALVE
CHECK VALVE
BUTTERFLY VALVE
BALL VALVE
PLUG VALVE EXISTING PIPING
NEW PIPINGE VALVE W/ ACTUATOR
E - ELECTRIC
P - PNEUMATIC
KNIFE GATE VALVE
SOLENOID VALVE
Mg(OH)2
PIPING DOWN
PIPING UP
PIPE REDUCER
CHEMICAL PIPING
ELECTRICAL SIGNALS
(ANALOG & DIGITAL)
SCADA SYSTEM COMM. LINK
(RADIO, DATA HIGHWAY)
FIBER OPTIC CABLE
F.O.
AIR PIPING
INSTRUMENTATION
AIR TUBING
AIR RELEASE VALVE
BACK PRESSURE
SUSTAINING VALVE
RELIEF VALVE
PIPING NOT CONNECTED
INSTRUMENTATION /
SENSOR
ULTRASONIC SENSOR
RADAR SENSOR
LEVEL (FLOAT) SWITCH
OIL FILLED GAUGE
PIPE TO FLOOR DRAIN
SPRAY NOZZLES
WATER SURFACE
MOTOR
GAUGE WITH DIAPHRAM
FLEX COUPLER
M
FE-XX
0-XXX GPM
INLINE "FLOW ELEMENT" METER
SLIDE GATE
CENTRIFUGAL PUMP
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\G-002.dwgLa st
E di te d by : A
A tti ck
G-002
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
PROCESS & INSTRUMENTATION SYMBOL SCHEDULE
PINCH VALVE
PLANT CONTROL PANELPCP
VENDOR CONTROL PANELVCP
GRIT CONTROL PANELGRCP
GRIT POWER PANELGRPP
PIPE CAP
INFLUENT PUMP
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\G-101.dwgLa st
E di te d by : A
A tti ck
G-101
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
00 30' 60'
SCALE:1 1" = 30'
AERIAL SITE PLAN - EXISTING CONDITIONS
AE
R
IA
L
SI
TE
P
LA
N
EX
IS
TI
N
G C
O N
D
IT
IO
N
S G
EN
ER
AL
OPERATIONS
BUILDING PLAN
D-101
1. INSTALLATION OF NEW 15 HP JOCKEY INFLUENT PUMP WITH VFD.
2. MODIFICATIONS TO EXISTING PIPING SYSTEMS.
3. UPGRADES TO EXISTING WWTP CONTROL PANEL FOR THE
INTEGRATION OF VFD AND NEW PROCESS INSTRUMENTATION.
4. FACILITATE INTEGRATION OF THE NEW EQUIPMENT INTO EXISTING
SCADA SYSTEM. INTEGRATION TO BE PERFORMED BY OWNER'S
INTEGRATOR - MARTZ TECHNOLOGIES, INC.
PROJECT SCOPE NOTES
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\G-601.dwgLa st
E di te d by : p m cc ar ty
G-601
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
PA
R
TI
AL
F O
R W
AR
D
F
LO
W P
R O
C
ES
S
AN
D
IN
ST
R
U M
EN
TT
IO
N
D
IA
G R
AM
G
EN
ER
AL
SCALE:1 NONE
SLUDGE PROCESS FLOW DIAGRAM
FE-122
0-2000 GPM
M
LS-101
PUMP
OFF 4.5' LE-101
(0-15FT)
LS-102
PUMP
ON 7.25'
VFD
P123
ASD LINE
REACTOR
P-123
SPARE
P-123 VFD
ASD OUTPUT
FILTER FOR
P-123
SCALE:2 NONE
MCC-100
LE-102
(0-15FT)
LS-103
PUMP
OFF 4.5'
LS-104
PUMP
ON 7.25
HOA
0-100%
HS
P123
-15-15
PSI
0-30
PSI
P-123
700 GPM @
38 FT TDH 15 HP
6"
8"
1-1/2"
LIT
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
3. PROCESS INSTRUMENTATION ARE FURNISHED AND INSTALLED BY THE
GC, WITH WIRING AND CONDUIT BY THE EC AND INTEGRATED BY THE
OWNERS INTEGRATOR MARTZ TECHNOLOGIES INC.
4. OWNERS INTEGRATOR (MARTZ) TO MODIFY EXISTING WWCP WITH
LEVEL INDICATING TRANSMITTER MOUNTED ON THE FACE OF THE
PANEL. AND PROVIDE A HOA AND P-123 VFD SPEED POTENTIOMETER.
5. OWNERS INTEGRATOR (MARTZ) TO MODIFY EXISTING WW PUMP
CONTROL CABINET WITH SPEED POTENTIOMETER FOR P-121 AND
P-122 VFDS.
ARV
6"
1/ 2"
SP-01 & SP-02
250 GPM 15 TDH
2 HP 208-230/460-3-60
FIT
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
D
EM
O
LI
TI
O
N P
LA
N
S, K
EY
ED
N O
TE
S
AN
D
P H
O
TO
G R
AP
H
S D
EM
O
LI
TI
O N
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\GED-401.dwgLa st
E di te d by : A
A tti ck
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
SCALE:1 3/16" = 1'-0"
UPPER LEVEL DEMOLITION PLAN
OPERATIONS BUILDING
0 8'4'2'1'
GED-401
SCALE:2 3/16" = 1'-0"
INTERMEDIATE LEVEL DEMOLITION PLAN
OPERATIONS BUILDING
0 8'4'2'1'
SCALE:3 3/16" = 1'-0"
LOWER LEVEL DEMOLITION PLAN
OPERATIONS BUILDING
0 8'4'2'1'
- GENERAL / MECHANICAL
DEMOLITION KEYNOTES
A. CORE HOLE WET WELL WALL FOR 8" DI SUCTION PIPE WITH LINK SEAL.
B. CORE HOLE WALL FOR NEW 1-1/2" AIR RELEASE DRAIN PIPE WITH LINK
SEAL.
C. REPLACE EXISTING 10" HEADER SPOOL PIECE WITH 10"x6" TEE FOR
CONNECTION TO 6" JOCKEY PUMP DISCHARGE PIPING.
D. CORE HOLE FLOOR FOR 6" DI SUCTION PIPE WITH LINK SEAL.
E. REPLACE EXISTING 10" WET WEATHER MAG METER.
F. DEMO EXISTING SUMP PUMPS IN THERE ENTIRETY FOR IN KIND
REPLACEMENTS.
G. DEMO EXISTING WET WELL BUBBLER (AIR-PURGE) LEVEL
MEASUREMENT EQUIPMENT. PULL POWER AND CONTROL WIRING
BACK TO IS SOURCE.
- ELECTRICAL / CONTROL
DEMOLITION KEYNOTES
A. JOCKEY PUMP (P-123) VARIABLE FREQUENCY DRIVE (VFD) LOCATION.
SCALE:A NONE
SUCTION PIPE WALL PENETRATION
WET WELL JOCKEY PUMP
SCALE:B NONE
DISCHARGE PIPE PENETRATION
SUMP AIR RELEASE VALVE
SCALE:C NONE
DISCHARGE PIPE CONNECTION
JOCKEY PUMP
SCALE:D NONE
PIPE FLOOR PENETRATION
JOCKEY PUMP SUCTION
SCALE:G NONE
MOTOR CONTROL CENTER (MCC-100)
A
A
C
D
G
C
D
A
A
C
D
A
B
E
B
SCALE:E NONE
WET WEATHER MAG METER (FE-122)
E
B
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
F
SCALE:F NONE
SUMP PUMPS
F
E
F
G
R
AT
IO
N
S
BU
IL
D
IN
G
IN
TE
R M
ED
IA
TE
A
N D
L O
W
ER
L
EV
EL
P
LA
N
S
AN
D N
O
TE
S
PR
O C
ES
S
M
EC
H
AN
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\D-101.dwgLa st
E di te d by : p m cc ar ty
D-101
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
A D-301
SHEET KEYNOTES
1. REPLACE IN KIND IN THEIR ENTIRETY THE TWO (2) WEIL VERTICAL
SEWAGE PUMPS MODEL NO. 2108 STAINLESS STEEL SHAFT, 3"
DISCHARGE, L46 BLUE 600 316SS IMPELLER 2 HP, 1750 RPM 3PH 60HZ,
205-230/480V TEFC: SERIAL NO. 2108J513.004. CONTRACTOR TO FIELD
VERIFY PUMP EQUIPMENT AND ALL OTHER CONNECTION.
SCALE:1 1/4" = 1'-0"
OPERATIONS BUILDING INTERMEDIATE LEVEL PLAN
0 4' 8'2'
SCALE:2 1/4" = 1'-0"
OPERATIONS BUILDING LOWER LEVEL PLAN
0 4' 8'2'
A D-301
B D-301
B D-301
10"x6"
REDUCING
TEE
LE-101
LS-101 &
LS-102
LE-102
LS-103 &
LS-104
6" 45° BEND
6" 90° BEND
6" D
I
8" PLUG VALVE
P-123
8" D
I
12"Ø CORE DRILL
WITH LINK SEAL.
GROUT BOTH SIDES.
8" 90° BEND
WITH BASE
8" DI
1 1/2" 90° LONG
RADIUS BEND
8" 90° FLARED
BEND
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
3. GC TO PROVIDE AND INSTALL PROCESS INSTRUMENTATION PER DIV 11
SPECIFICATION. EC TO PROVIDE POWER AND CONTROL WIRING.
FE-122
1.5" SCH 80 PVC
@ 2% SLOPE
D-501
C D-301
8" 45° BEND
8" D
I
C D-301
1 1/2" 90° LONG
RADIUS BEND
R
AT
IO
N
S
BU
IL
D
IN
G
S
EC
TI
O
N S
PR
O
C
ES
S M
EC
H
AN
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\D-301.dwgLa st
E di te d by : p m cc ar ty
D-301
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
SCALE:A 1/4" = 1'-0"
OPERATIONS BUILDING SECTION
0 4' 8'2'
SCALE:B 1/4" = 1'-0"
OPERATIONS BUILDING SECTION
0 4' 8'2'
6" D
I
6" DI
10"x6"
REDUCING TEE
10" FLANGE ADAPTER
6" CHECK VALVE
10"Ø CORE DRILL
WITH LINK SEAL.
GROUT BOTH SIDES.
8" DI
8" 90° BEND W/ BASE
8" PLUG VALVE
8" DI
P-123
6" DI
1.5" SCH 80 PVC
@ 2% SLOPE
5" CORE DRILL HOLE
WITH LINK SEAL
12"Ø CORE DRILL
WITH LINK SEAL.
GROUT BOTH SIDES.
10"x6" REDUCING TEE
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
D-501
D-501
D-501
D-501
D-501
PIPE SUPPORT
D-501
8" FLARED
90° BEND
8"x6" REDUCER
6" 90° BEND
(TYP. 4 PLCS.)
6" PLUG VALVE
SCALE:C 1/4" = 1'-0"
OPERATIONS BUILDING SECTION
0 4' 8'2'
8" 90° BEND W/ BASE
8"x6" REDUCER 6"
D I
6" D
I
6" 90° BEND
(TYP. 3 PLCS.)
6" PLUG VALVE
6" CHECK VALVE
10"Ø CORE DRILL
WITH LINK SEAL.
GROUT BOTH SIDES.
6" D
I
6" D
I
HOSE BIB
1% SLOPE
SHEET KEYNOTES
1. CONTRACTOR TO LOCATE EXISTING REINFORCING STEEL IN FLOOR
PRIOR TO CORING THE FLOOR. EXISTING REINFORCEMENT STEEL SHALL
NOT BE CUT.
2. PROVIDE EQUIPMENT PAD (4" HIGH). VERIFY PAD SIZE WITH EQUIPMENT
MANUFACTURER. ROUGHEN CONCRETE SURFACE. COAT WITH EPOXY
ADHESIVE PRIOR TO PLACEMENT OF CONCRETE REINFORCEMENT: #4 "U"
BAR DOWELS @ 12"(TYP. EACH WAY). DRILL (3/4" DIAM.) HOLES MINIMUM
(4") DEPTH. EPOXY ADHESIVE REINFORCEMENT IN-PLACE USING HILTI HIT
RE-500 V3. GEL TIME AND FULL CURE TIME PER MANUFACTURER'S
RECOMMENDATIONS. ALL EXPOSED EDGES SHALL HAVE (3/4") CHAMFERS.
EQUIPMENT ANCHORING PER MANUFACTURES RECOMMENDATIONS.
3. VERIFY PAD SIZE WITH EQUIPMENT MANUFACTURER. ROUGHEN
CONCRETE SURFACE. COAT WITH EPOXY ADHESIVE PRIOR TO
PLACEMENT OF CONCRETE REINFORCEMENT: #4 "U" BAR DOWELS @
12"(TYP. EACH WAY). DRILL (3/4" DIAM.) HOLES MINIMUM (4") DEPTH.
EPOXY ADHESIVE REINFORCEMENT IN-PLACE USING HILTI HIT RE-500 V3.
GEL TIME AND FULL CURE TIME PER MANUFACTURER'S
RECOMMENDATIONS. ALL EXPOSED EDGES SHALL HAVE (3/4") CHAMFERS.
EQUIPMENT ANCHORING PER MANUFACTURES RECOMMENDATIONS.
4. PROVIDE REPLACEMENT PARTS FOR EXISTING INFLUENT PUMPS P-121
AND 122 GORMAN RUPP PUMP MODEL:T10A-B-7, AT A MINIMUM
REPLACEMENT PARTS SHALL INCLUDE TWO (2) SET OF EACH OF THE
FOLLOWING: MECHANICAL SEAL KIT, IMPELLER, WEAR PLATE, AND COVER
PLATE, AND COVER PLATE O-RING, BACK COVER O-RING, BEARINGS, AND
SHAFT SLEEVE. PUMP SERIAL NUMBER SHALL BE FIELD VERIFIED AND
REPLACEMENT PARTS TO BE PROVIDED BY THE ORIGINAL
MANUFACTURER.
5. PROVIDE REPLACEMENT PARTS FOR EXISTING INFLUENT PUMPS CHECK
VALVES, AT A MINIMUM REPLACEMENT PARTS SHALL INCLUDE: FLAP,
HINGE PIN, AND SEAL. CHECK VALVE SERIAL NUMBER SHALL BE FIELD
VERIFIED AND REPLACEMENT PARTS TO BE PROVIDED BY THE ORIGINAL
MANUFACTURE.
4 4
2 2
6" 90° BEND
(TYP. 3 PLCS.)
8" DI
8" 45° BEND
IN
ST
R U
M
EN
TA
TI
O N
D
ET
AI
LS
PR
O
C
ES
S M
EC
H
AN
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\D-501.dwgLa st
E di te d by : A
A tti ck
D-501
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
ARA
DBK
BJM
/1
6/
D
BI
D
D
IN
G
BJ
M
F O
HTLAEWNOM
M O
C
AI
NAVLYSNNE
P
ERIC JULIAN MOORE
ENGINEER
056852-E
PROFESSIONAL
REGISTERED
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
SCALE:1 NONE
MAGNETIC FLOW METER (FE-122)
RACK, HANDRAIL OR WALL
REMOTE MOUNTED
INDICATOR/TRANSMITTER
FIT-XXX
TRANSMITTER OR JUNCTION BOX
FOR REMOTE MOUNTED TRANSMITTER
GROUNDING RING (TYP.)
GROUNDING WIRE (TYP.)
SCALE:5 NONE
FLOAT MOUNTING DETAIL (LS-XX)
FLOAT SWITCH
(TYP.)
FLOAT MOUNTING BRACKET
S.S. HOOK (TYP.)
PUMP STATION / TANKS
PRESSURE
TRANSDUCER
LE-XXX
6"
4" SCH. 80 PVC
STILLING PIPE W/
1/2"Ø HOLES
POTTED CABLE W/ 30' MIN.
LENGTH TO TERMINAL BOX
SCALE:4 NONE
DETAIL (LE-XXX)
PRESSURE TRANSDUCER
SCALE:6 NONE
PRESSURE DIAPHRAGM GAUGE DETAIL
1/2" FULL PORT
BALL VALVE
DIAPHRAGM SEAL
4-1/2"Ø OIL FILLED
PRESSURE GAUGE
VA
R
IE
S
(R
EF
ER
T
O P
LA
N
S)
-BASIS OF DESIGN: TAYLOR WALRAVEN #87, HOT DIPPED GALVANIZED-SCALE:3 NONE.
ADJUSTABLE SADDLE CLAMP PIPE SUPPORT PS-4
PROCESS PIPING
(SIZE VARIES)SADDLE STRAP
*V
AR
IE
S*
FI
EL
D V
ER
IF
Y
SCALE:2 NONE.
ADJUSTABLE CLEVIS / HILTI PIPE SUPPORT
PROCESS PIPING
(SIZE VARIES)
3/4"Ø HILTI HDI CONCRETE
ANCHORS, 5" EMBEDMENT
CONTINUOUS THREADED ROD
(GALV.) ANVIL FIG. 146 (TYP.)
CONTINUOUS THREADED ROD
(GALV.) ANVIL FIG. 146 (TYP.)
ADJUSTABLE CLEVIS HANGER
(GALV.) ANVIL FIG. 590
HEX JAM NUTS (GALV.) TYP.
LC
-BASIS OF DESIGN: STANDON C-92, STAINLESS STEEL-SCALE:7 NONE.
ADJUSTABLE SADDLE CLAMP PIPE SUPPORT PS-3
4" S.S. AIR PIPING
VE
R
IF
Y
IN
F
IE
LD
1/2"x2"
SADDLE STRAP
1"x6" THREAD STUD
SCH. 40 S.S. PIPE
1"Ø HEX JAM NUT
3/4" GROUT
PROVIDE (4) 1/2"Ø HILTI KWIK BOLT 3
STAINLESS STEEL EXPANSION ANCS.
INTO CONCRETE (3 1/4" EMBEDMENT).
S.S. BASE PLATE
12" DIA. SONOTUBE
3' -6
2"
2" CL.
(TYP. ALL AROUND)
#4 TIES @ 12 O.C.
(8) #5's EQ. SPA.
(VERT.)
GRADE.
NOTE:
4000 PSI CONCRETE.
GRADE.
VFD
123 3
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
U
PP
ER
L
EV
EL
P
LA
N A
N D
N O
TE
S
EL
EC
TR
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\E-101.dwgLa st
E di te d by : A
A tti ck
E-101
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
JED
DEM
DEM
/1
6/
D
BI
D
D
IN
G
BJ
M
P
E N N S Y L V A N
I A056260NO.
DAVID E. MACE
C O
M
M O N W E A L T H
O F
ENGINEER
PROFESSIONAL
REGISTERED
SCALE:1 1/4" = 1'-0"
OPERATIONS BUILDING UPPER LEVEL PLAN
0 4' 8'2'
SHEET KEYNOTES
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS
3. REFER TO TECHNICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL
PROJECT REQUIREMENTS.
4. REFER TO DRAWING E-502 FOR ELECTRICAL LEGEND.
1. THE JOCKEY PUMP (P-123) VARIABLE FREQUENCY DRIVE (VFD) SHALL BE
INSTALLED WITHIN MCC-100, IN SECTION 3, USING THE MODEL 6 MCC
STANDARD PACKAGE. THE DRIVE SHALL BE AN ALTIVAR 630 PROCESS
AC DRIVE, RATED AT 15 HORSEPOWER, COMPLETE WITH AN INTEGRAL
CIRCUIT BREAKER AND DESIGNED FOR NORMAL-DUTY OPERATION WITH
AN OVERCURRENT CAPACITY OF 110% FOR 60 SECONDS. THE DRIVE
SHALL HAVE A CATALOG DESIGNATION OF ATV630D11 AND BE SUITABLE
FOR USE WITH A SYSTEM IMPEDANCE OF 5 PERCENT. THE VFD SHALL
INCLUDE A MOTOR-PROTECTING FILTER, A 100 VA CONTROL POWER
TRANSFORMER, #16 AWG MTW CONTROL WIRING, AND FISHTAPE UNIT
PLUGS. THE OVERALL DEVICE HEIGHT SHALL NOT EXCEED 24 INCHES.
1.1. ASSOCIATED MISCELLANEOUS DEVICES SHALL INCLUDE A LINE
REACTOR AND A MOTOR-PROTECTING FILTER, BOTH SUITABLE FOR
USE WITH THE SPECIFIED DRIVE. ALL COMPONENTS SHALL BE
FACTORY ASSEMBLED, TESTED, AND INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE
CODES AND STANDARDS.
1.2. CONTRACTOR SHALL COORDINATE WITH SQUARE D ON THE
PACKAGE TO FIT THE EXISTING MCC ENCLOSURE. THE FO NUMBER
FOR THE EXISTING MCC IS: 31840059-003.
3. RUN POWER CONDUIT FROM MCC-100 (LOCATED IN OPERATIONS
BUILDING UPPER LEVEL PLAN) TO P-123 DISCONNECT IN OPERATIONS
BUILDING INTERMEDIATE LEVEL PLAN (REFER TO SHEET E-102). PROVIDE
NEW NEMA 12/4X STAINLESS STEEL, 3-POLE, 60A NON-FUSIBLE
DISCONNECT SWITCH FOR LOCAL LOCKOUT OF MOTOR. WHERE USED
ON VFD-CONTROLLED MOTOR, PROVIDE AUXILIARY CONTACT WIRED TO
BREAK BEFORE BLADES OPEN TO DROP OUT VFD PRIOR TO OPENING
MOTOR LEADS.
3.1. THIS INSTALLATION WILL REQUIRE NEW CONDUIT. CONDUIT SHALL
BE FIELD ROUTED DUE TO MULTIPLE OBSTRUCTIONS IN THE AREA.
A TOTAL OF FOUR (4) CONDUITS SHALL BE PROVIDED FROM
MCC-100 AS FOLLOWS:
• ONE (1) CONDUIT FOR POWER AND AUX CONTACT TO THE P-123
DISCONNECT.
• ONE (1) CONDUIT FOR CONTROL WIRING TO THE WET WELL
CONTROL PANEL (WWCP).
• ONE (1) CONDUIT FOR DATA WIRING TO THE WET WELL CONTROL
PANEL (WWCP).
• ONE (1) SPARE CONDUIT TO THE WET WELL CONTROL PANEL
(WWCP).
3.2. ALL CONDUITS SHALL BE SIZED PER 2017 NEC REQUIREMENTS AND
PROJECT SPECIFICATIONS. PROVIDE CONDUIT AS APPROPRIATE
FOR THE INSTALLATION ENVIRONMENT. INSTALL IN ACCORDANCE
WITH 2017 NEC AND PROJECT STANDARDS.
NOTES:
1. COORDINATE W/APPROPRIATE EQUIPMENT MANUFACTURER BEFORE
CONNECTING COMPONENT
2. S.T.P = SHIELDED TWISTED PAIR
3. V.S.C. = VENDOR PROVIDED CABLE
4. #14AWG = #14 AWG, THHN INSULATED COPPER CONDUCTORS
5. ALL ANALOG WIRING SHALL BE INSTALLED IN RGS CONDUIT
6. CAT.6 = CATEGORY 6 RATED DATA CABLE, WITH RJ-45 JACK FITTED TO
EACH END.
1A P-123 VFD C WWCP 14AWG 6 1"
1B P-123 VFD C WWCP S.T.P 2 1"
1C P-123 VFD C WWCP CAT 6 1 3/4"
1D P-123 VFD C WWCP SPARE 3/4"
* = EXPOSED RACEWAY ONLY, 1 INCH MINIMUM EMBEDDED SIZE. SIZE
SHOWN IS MINIMUM FOR SINGLE CIRCUIT. CIRCUITS OF LIKE NOISE
LEVEL MAY BE COMBINED.
** = INTRINSICALLY SAFE WIRING MUST BE HOUSED IN SEPARATE RACEWAY
PER NEC.
DATA/CONTROL SCHEDULE
KEYNOTE FROM TO CABLE No. OF RACEWAY
TYPE CABLES SIZE *
1A 1B 1C 1D
FE
122 2H
P-123
DISC 2I
2G
LS
103 2E
LS
104 2F
LS
101 2C
LS
102 2D
LE
1022B
LE
1012A
O
PE
R
AT
IO
N
S
BU
IL
D
IN
G
IN
TE
R M
ED
IA
TE
A
N D
L O
W
ER
L
EV
EL
P
LA
N
S
AN
D N
O
TE
S
EL
EC
TR
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\E-102.dwgLa st
E di te d by : A
A tti ck
E-102
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
JED
DEM
DEM
/1
6/
D
BI
D
D
IN
G
BJ
M
P
E N N S Y L V A N
I A056260NO.
DAVID E. MACE
C O
M
M O N W E A L T H
O F
ENGINEER
PROFESSIONAL
REGISTERED
SCALE:1 1/4" = 1'-0"
OPERATIONS BUILDING INTERMEDIATE LEVEL PLAN
0 4' 8'2'
6" D
I
P-123
SHEET KEYNOTES
GENERAL SHEET NOTES
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS
3. REFER TO TECHNICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL
PROJECT REQUIREMENTS.
4. REFER TO DRAWING E-502 FOR ELECTRICAL LEGEND.
1. PROVIDE AN APPROPRIATELY SIZED JUNCTION BOX (JB-1A), RATED FOR
THE INSTALLATION AREA, TO TRANSITION VENDOR-FURNISHED LEVEL
SWITCH CABLES AND LEVEL INSTRUMENT CABLE TO BUILDING WIRING.
BUILDING WIRING SHALL BE ROUTED BACK TO THE WET WELL CONTROL
PANEL (WWCP). UTILIZE EXISTING CONDUIT WHERE FEASIBLE TO
MINIMIZE NEW CONDUIT INSTALLATION. VERIFY EXISTING CONDUIT SIZE,
CONDITION, AND ROUTING TO ENSURE ADEQUATE CAPACITY FOR NEW
WIRING IN ACCORDANCE WITH NEC FILL REQUIREMENTS. IF EXISTING
CONDUIT IS UNDERSIZED, DAMAGED, OR OTHERWISE UNSUITABLE,
PROVIDE NEW CONDUIT OF ADEQUATE SIZE AND TYPE AS REQUIRED.
ALL NEW CONDUIT SHALL BE RATED FOR THE INSTALLATION
ENVIRONMENT AND INSTALLED IN ACCORDANCE WITH THE 2017 NEC.
REFER TO G-601 FOR ADDITIONAL INFORMATION ON TRANSMITTER
WIRING.
2. PROVIDE AN APPROPRIATELY SIZED JUNCTION BOX (JB-1B), RATED FOR
THE INSTALLATION AREA, TO TRANSITION VENDOR-FURNISHED LEVEL
SWITCH CABLES AND LEVEL INSTRUMENT CABLE TO BUILDING WIRING.
BUILDING WIRING SHALL BE ROUTED BACK TO THE WET WELL CONTROL
PANEL (WWCP). UTILIZE EXISTING CONDUIT WHERE FEASIBLE TO
MINIMIZE NEW CONDUIT INSTALLATION. VERIFY EXISTING CONDUIT SIZE,
CONDITION, AND ROUTING TO ENSURE ADEQUATE CAPACITY FOR NEW
WIRING IN ACCORDANCE WITH NEC FILL REQUIREMENTS. IF EXISTING
CONDUIT IS UNDERSIZED, DAMAGED, OR OTHERWISE UNSUITABLE,
PROVIDE NEW CONDUIT OF ADEQUATE SIZE AND TYPE AS REQUIRED.
ALL NEW CONDUIT SHALL BE RATED FOR THE INSTALLATION
ENVIRONMENT AND INSTALLED IN ACCORDANCE WITH THE 2017 NEC.
REFER TO G-601 FOR ADDITIONAL INFORMATION ON TRANSMITTER
WIRING.
3. PROVIDE A VENDOR-FURNISHED MAGNETIC FLOW METER WITH A
REMOTE-MOUNTED INDICATOR/TRANSMITTER (FIT-122). THE VENDOR
SHALL SUPPLY AND INSTALL THE INTERCONNECTING CABLE BETWEEN
THE REMOTE-MOUNTED TRANSMITTER AND THE FLOW METER. BUILDING
WIRING SHALL BE PROVIDED FROM THE REMOTE-MOUNTED
TRANSMITTER TO THE WET WELL CONTROL PANEL (WWCP). A SEPARATE
JUNCTION BOX IS NOT REQUIRED, AS THE TRANSMITTER WILL SERVE AS
THE TRANSITION POINT BETWEEN THE VENDOR-FURNISHED CABLE AND
THE BUILDING WIRING. UTILIZE EXISTING CONDUIT WHERE FEASIBLE TO
MINIMIZE NEW CONDUIT INSTALLATION. VERIFY THE SIZE, CONDITION,
AND ROUTING OF EXISTING CONDUIT TO ENSURE IT CAN
ACCOMMODATE NEW WIRING IN ACCORDANCE WITH NEC CONDUIT FILL
REQUIREMENTS. IF EXISTING CONDUIT IS UNDERSIZED, DAMAGED, OR
OTHERWISE UNSUITABLE, PROVIDE NEW CONDUIT OF ADEQUATE SIZE
AND TYPE RATED FOR THE INSTALLATION ENVIRONMENT. ALL NEW
CONDUIT AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH
THE 2017 NEC AND APPLICABLE PROJECT SPECIFICATIONS.REFER TO
G-601 FOR ADDITIONAL INFORMATION ON TRANSMITTER WIRING.
NOTES:
1. COORDINATE W/APPROPRIATE EQUIPMENT MANUFACTURER BEFORE
CONNECTING COMPONENT
2. S.T.P = SHIELDED TWISTED PAIR
3. V.S.C. = VENDOR PROVIDED CABLE
4. #14AWG = #14 AWG, THHN INSULATED COPPER CONDUCTORS
5. ALL ANALOG WIRING SHALL BE INSTALLED IN RGS CONDUIT
6. CAT.6 = CATEGORY 6 RATED DATA CABLE, WITH RJ-45 JACK FITTED TO
EACH END.
7. F.O.C. = FIBER OPTIC CABLE
2A LE-101 WWCP V.S.C 6 3/4"
2B LE-102 WWCP V.S.C 2 3/4"
2C LS-101 WWCP V.S.C 1 3/4"
2D LS-102 WWCP V.S.C 1 3/4"
2E LS-103 WWCP V.S.C 1 3/4"
2F LS-104 WWCP V.S.C 1 3/4"
2G FE-122 FIT-122 V.S.C 1 N/A
2H FIT-122 WWCP S.T.P 2 3/4"
2I P-123 DISC MCC-100 14 AWG 2 3/4"
* = EXPOSED RACEWAY ONLY, 1 INCH MINIMUM EMBEDDED SIZE. SIZE
SHOWN IS MINIMUM FOR SINGLE CIRCUIT. CIRCUITS OF LIKE NOISE
LEVEL MAY BE COMBINED.
** = INTRINSICALLY SAFE WIRING MUST BE HOUSED IN SEPARATE RACEWAY
PER NEC.
DATA/CONTROL SCHEDULE
KEYNOTE FROM TO CABLE No. OF RACEWAY
TYPE CABLES SIZE *
SCALE:2 1/4" = 1'-0"
OPERATIONS BUILDING LOWER LEVEL PLAN
0 4' 8'2'
8" D
I
1 1/2" 90° LONG
RADIUS BEND
6" DI
EL
EC
TR
IC
AL
L
EG
EN
D
EL
EC
TR
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\E-501.dwgLa st
E di te d by : A
A tti ck
E-501
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
JED
DEM
DEM
/1
6/
D
BI
D
D
IN
G
BJ
M
P
E N N S Y L V A N
I A056260NO.
DAVID E. MACE
C O
M
M O N W E A L T H
O F
ENGINEER
PROFESSIONAL
REGISTERED
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS
3. REFER TO TECHNICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL
PROJECT REQUIREMENTS.
GENERAL SHEET NOTES
OL
G
HP
J
NEW EXPOSED WIRING IN RACEWAY
NEW WIRING CONCEALED IN CEILING, WALL OR
UNDERGROUND
CONDUIT TURNING DOWN
CONDUIT TURNING UP
JUNCTION BOX
MOTOR, HORSEPOWER AS INDICATED ON PLANS
EQUIPMENT DESIGNATION REFER TO GENERAL,
MECHANICAL & PLUMBING DRAWINGS FOR
SCHEDULES
FUSE
CIRCUIT BREAKER
FUSED DISCONNECT SWITCH
NON-FUSED DISCONNECT SWITCH
PULL OUT DISCONNECT
TRANSFORMER
GENERATOR
GROUND
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
OVERLOAD RELAY
CONDUCTORS NOT CONNECTED
CONDUCTORS CONNECTED
DISTRIBUTION PANELBOARD, SWITCHBOARD OR
MOTOR CONTROL CENTER, SHOWN TO SCALE
ON PLANS
DISCONNECT SWITCH, TYPE AND SIZE AS
INDICATED ON DRAWINGS
HEAT TRACE POWER CONNECTION KIT
CONTROL STATION (TYPE AS SHOWN)
PHOTO CELL
ELECTRICAL SYMBOL LEGEND
LP1-14
A,b
EXISTING EXPOSED WIRING IN RACEWAY
EXPLOSION PROOFXP
P
PC
LUMINAIRE, TYPE AS INDICATED ON LUMINAIRE
SCHEDULE ON SHEET E-501. LETTER = LUMINAIRE TYPE,
lower case letter = SWITCH DESIGNATION
A,b
IN-WALL, ON/OFF W/ 0-10V DIMMING
LUTRON: DVSCSTV, OR APPROVED EQUAL, CONNECT 0-10V DIMMING
WIRE TO ALL LOCAL LUMINAIRES IN ROOM OR AREA NOTED.
IN-WALL, SINGLE POLE SWITCH
IN-WALL, THREE-WAY SWITCH
IN-WALL, ON/OFF W/ OCCUPANCY SENSOR
LUTRON: MRF2S-8SS-WH, OR APPROVED EQUAL, CONNECT TO
LOCAL LUMINAIRES IN ROOM OR AREA NOTED. AUTO ON, AUTO OFF,
SET TO VACANCY MODE IN ALL PRIVATE OFFICES AND SMALL ROOMS.
SD,a
SM
S3
S
CEILING MOUNTED WIRELESS MOTION SENSOR, LUTRON
LRF2-OCR2B-P-WH, OR APPROVED EQUAL , PAIR TO LOCAL
CONTROL MODULE/SWITCH
WALL MOUNTED MOTION SENSOR 90°, PROVIDE
LUTRON:LRF2-OKLB-P-WH, OR APPROVED EQUAL, PAIR TO LOCAL
CONTROL MODULE/SWITCH MOUNT AT 8'-0" A.F.F.
OS
OS
NEW 120VOLT, 20AMP,DUPLEX RECEPTACLE, NEMA 5-20R
MOUNTED AT 18" AFF; UNLESS NOTED OTHERWISE. PROVIDE
TYPED LABEL ON EACH RECEPTACLE COVERPLATE
W/PANELBOARD NAME AND CIRCUIT NUMBER. CLEAR LABEL W/
BLACK LETTER, 3/32" HIGH. CONNECT TO CIRCUIT SHOWN.
NO DENOTE=NEW OUTLET AT MOUNTED 18",
# = CIRCUIT NUMBER
##" = HEIGHT ABOVE FINISH FLOOR
AC = NEW OUTLET, MOUNT 8" ABOVE COUNTER TOP,
GFI = INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER.
WP = WEATHER PROOF WHILE IN USE ENCLOSURE W/
WEATHER RESISTANT RECEPTACLE.
ETR = EXISTING LOCATION TO REMAIN, REPLACE W/ NEW
RECEPTACLE AND COVERPLATE.
TV = INSTALL FOR WALL MOUNTED TV, MOUNT BEHIND TV
USB = PROVIDE W/ ONE USB-A AND ONE USB-C PORT
WM = PROVIDE DECORATOR RECEPTACLE IN WIREMOLD
ALDS4000 SYSTEM W/ALDS4047R RACEWAY FITTING.
A,b
LIGHT SWITCH W/ WET LOCATION/WEATHER PROOF COVER PLATE.SWP
VC
EX
VIDEO CAMERA, MARCH NETOWRKS
EX = EXISTING VIDEO CAMERA AND CAMERA MOUNT,
RELOCATED TO NEW LOCATION SHOWN. PROVIDE 3/4"
CONDUIT W/ CAT5E CABLE AND PULL STRING BACK TO
DATA CLOSET SWITCH.
N = PROVIDE NEW VIDEO CAMERA, PROVIDE MARCH
NETWORKS VA4 OUTDOOR IR DOME W/ 1.5" NPT WALL
MOUNT & 1.5" NPT SUNSHIELD. PROVIDE 3/4" CONDUIT
W/ CAT5E CABLE AND PULL STRING BACK TO DATA
CLOSET SWITCH.
PTZ = EXISTING PTZ VIDEO CAMERA AND CAMERA MOUNT
RELOCATED FROM CONTROL BUILDING TO NEW
ADMIN BUILDING. AIM TOWARDS ENTRANCE
GATE. PROVIDE 3/4"CONDUIT W/ CAT5E CABLE AND
PULL STRING BACK TO DATA CLOSET SWITCH.
F
AVF
S
CM CARBON MONOXIDE DETECTOR
SMOKE DETECTOR
AUDIO/VISUAL DEVICE
PULL STATION
VF VISUAL DEVICE
2 DATA/PHONE OUTLET, MOUNTED AT 18" AFF UNLESS OTHERWISE
NOTED. PROVIDE SINGLE GANG J-BOX, 3/4" CONDUIT WITH
NUMBER OF CAT 6 CABLES NOTED FROM LOCATION TO DATA
CLOSET. PROVIDE RJ45 JACKS AND COVER PLATE. TERMINATE
CAT6 CABLING ON PATCH PANEL. NUMBER NOTES QUANTITY OF
CAT6 CABLES AT LOCATION.
NO DENOTE=NEW OUTLET AT MOUNTED 18",
# = NUMBER OF OUTLETS
##" = HEIGHT ABOVE FINISH FLOOR
AC = NEW OUTLET, MOUNT 8" ABOVE COUNTER TOP
WM = PROVIDE IN WIREMOLD ALDS4000 SYSTEM
W/ ALDS4047R RACEWAY FITTING. PROVIDE
REQUIRED ACCESSORIES FOR MOUNTING RJ45
JACKS.
IN-WALL, MOTION SENSOR W/ 0-10V DIMMING (VACANCY)
LUTRON: MRF2S-8SD010-WH, OR APPROVED EQUAL, CONNECT
0-10V DIMMING WIRE TO ALL LOCAL LUMINAIRES IN ROOM OR
AREA NOTED. SET TO VACANCY MODE IN ALL PRIVATE OFFICES
AND SMALL ROOMS. TIME DELAY MAX 20 MINUTES.
SWITCH ID/ZONE CONTROLLED, CONNECT TO CORRESPONDING
LUMINAIRES. BLANK CONNECT TO LOCAL LUMINAIRES IN THE
SAME ROOM. TYPICAL FOR ALL SWITCHES.
SDM,a
PROVIDE WIREMOLD ALDS4000 SERIES (OR APPROVED EQUAL),
ALUMINUM RACEWAY SYSTEM W/ DUAL CHANNELS, TWIN
COVERS AND BUILT IN DIVIDER THAT PROVIDES FULL ISOLATION
BETWEEN DATA AND POWER. PROVIDE WITH FRONT FACING
DATA AND POWER ACTIVATIONS. MOUNT ABOVE COUNTERTOP
BACK SPLASH. COORDINATE LIVE END FEEDS WITH EXISTING
CONDITIONS. PROVIDE END PLATES, CORNERS, ELBOWS AS
REQUIRED. PROVIDE DS4000WC WIRE CLIPS FOR CABLE
MANAGEMENT IN BOTH DATA AND POWER CHANNELS.
PD PROPANE DETECTOR
BRANCH CIRCUIT HOMERUN TO PANEL ,
NUMBER OF ARROWS = NUMBER OF
RACEWAYS. ALPHA-NUMERIC DESIGNATION =
PANEL - CIRCUIT #
NEW 120VOLT, 20AMP, QUAD RECEPTACLE, TWO NEMA 5-20R
MOUNTED AT 18" AFF; UNLESS NOTED OTHERWISE. PROVIDE
TYPED LABEL ON EACH RECEPTACLE COVERPLATE
W/PANELBOARD NAME AND CIRCUIT NUMBER. CLEAR LABEL W/
BLACK LETTER, 3/32" HIGH. CONNECT TO CIRCUIT SHOWN.
DENOTES SAME AS ABOVE.
EL
EC
TR
IC
AL
D
ET
AI
LS
EL
EC
TR
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\E-502.dwgLa st
E di te d by : A
A tti ck
E-502
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
JED
DEM
DEM
/1
6/
D
BI
D
D
IN
G
BJ
M
P
E N N S Y L V A N
I A056260NO.
DAVID E. MACE
C O
M
M O N W E A L T H
O F
ENGINEER
PROFESSIONAL
REGISTERED
CABLE SEAL (TYP.) CROUSE-HINDS #CGB,
OR APPROVED EQUIVALENT
ROUND HOLE STOCK (ALUMINUM
3003H14)-.125" THICK 1/4" DIAMETER,
40% OPEN AREA WITH MARGIN (TYP.)FINISHED
GRADE
CORE DRILL HOLES SIZED FOR
CONDUIT SLEEVES. SEAL
PENETRATION BY APPROVED MEANS.
DO NOT CUT REBAR. (TYP)
WET WELL COVER
BUSHING (TYP)
WET WELL
SCALE:1 NONE
TYPICAL AIR-GAP ASSEMBLY DETAIL
PUMP DISC SWITCH
(MOTOR/SENSOR CABLES)
CLASS 1, DIV. 1, GROUP D
HAZARDOUS ENVIRONMENT
1' -8
" M
IN
BO
TT
O
M O
F
EN
C L
3/8" S.S. OPEN EYE BOLT
S.S. KELLEMS TYPE CABLE GRIP
PUMP/SENSOR POWER CORDS
UNISTRUT WALL STAND-OFF
(TYP. TOP AND BOTTOM/EQUIP.)
1' -8
" M
IN
BO
TT
O
M O
F
EN
C L
3/8" S.S. OPEN EYE BOLT
S.S. KELLEMS TYPE CABLE GRIP
TERM.
BOX
'WWTB'
GENERAL ELECTRICAL NOTES
1. ALL BRANCH CIRCUIT WIRING SHALL BE 2#12 & 1#12 GRD., 3/4" CONDUIT,
UNLESS NOTED OTHERWISE (PROVIDED SEPARATE NEUTRALS AND
SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR
FOR ALL FEEDER AND BRANCH CIRCUITS). TERMINATE EACH GROUNDING
CONDUCTOR ON A GROUNDING LUG, BUS, OR BUSHING. ALL BRANCH
CIRCUIT WIRING IS SHOWN DIAGRAMMATIC. CONTRACTOR SHALL
COORDINATE ACTUAL CIRCUIT ROUTING WITH OTHER TRADES AND
BUILDING CONSTRUCTION.
2. SEAL ALL CONDUIT PENETRATIONS THROUGH WALLS AND SLABS
WATERTIGHT.
3. ALL NEW WIRING SHALL BE ROUTED PLUMB AND SQUARE, IN RACEWAY.
PROVIDE PULL BOXES AT LOCATIONS NEEDED, AND ADEQUATELY SIZED
AS REQUIRED FOR THE EQUIPMENT SERVED.
4. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL EQUIPMENT/DEVICE
REQUIREMENTS FOR EQUIPMENT PROVIDED. CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL ASSOCIATED EQUIPMENT & TERMINATIONS TO
EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS.
5. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED, AND
SHALL MEET THE REQUIREMENTS OF BOTH THE NATIONAL ELECTRICAL
CODE (NEC 2017, ARTICLE 250), AND THE EQUIPMENT/SYSTEM
MANUFACTURER'S REQUIREMENTS FOR TYPES, SIZES, AND QUANTITIES
OF EQUIPMENT GROUNDING CONDUCTORS, EXCEPT WHERE SPECIFIC
TYPES, LARGER SIZES, OR MORE CONDUCTORS THAN REQUIRED BY NEC
ARE INDICATED.
6. THE CONTRACTOR SHALL VERIFY DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO THE START OF THE WORK, NOTIFY THE ENGINEER
OF ANY SIGNIFICANT CHANGES IN DIMENSIONS AND CONDITIONS.
7. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, TOOLS, EQUIPMENT,
AND NECESSARY FACILITIES, AND PERFORM ALL LABOR AND SERVICES
OF EVERY DESCRIPTION AS MAY BE NECESSARY TO COMPLETE THE
SCOPE OF THE WORK DEFINED IN THE CONTRACT DOCUMENTS.
8. FABRICATE AND INSTALL ALL WORK IN STRICT ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE (NEC 2017), THE NATIONAL ELECTRICAL
SAFETY CODE (NESC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA),
INTERNATIONAL BUILDING CODE (IBC2015), AMERICANS WITH
DISABILITIES ACT (ADA), NECA STANDARD OF INSTALLATION, OSHA, ALL
APPLICABLE STATE AND LOCAL CODES, GENERAL CONDITIONS AND
SUPPLEMENTAL TERMS OF THE CONTRACT. ALL EQUIPMENT SHALL BE
UNDERWRITERS LABORATORIES (U.L.) LISTED FOR ITS APPLICATION
WHERE SUCH ITEMS ARE REQUIRED.
9. ALL CONTRACTORS AND SUBCONTRACTORS SHALL BE RESPONSIBLE
FOR THE PROPER PERFORMANCE OF THEIR WORK, COORDINATION WITH
OTHER TRADES, MEANS AND METHODS OF CONSTRUCTION, AND SAFETY
AND SECURITY WHILE ON SITE.
10. PROTECT EXISTING PROPERTY DURING CONSTRUCTION. REPAIR OR
REPLACE, WITHOUT ADDITIONAL CHARGE TO THE OWNER, ANY EXISTING
WORK DAMAGED DURING THE COURSE OF CONSTRUCTION.
11. THE CONTRACT DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO
CONVEY, IN A GENERAL WAY, THE SCOPE OF THE WORK. THEY ARE NOT
INTENDED TO ILLUSTRATE ALL CONDITIONS WHICH MAY BE
ENCOUNTERED AT THE SITE.
12. UNDERGROUND RACEWAYS SHALL BE SCHEDULE 40 PVC, UNLESS
OTHERWISE NOTED. UNDERGROUND RACEWAYS SHALL TRANSITION TO
RIGID GALVANIZED STEEL PRIOR TO EMERGING FROM THE GROUND. ALL
EXPOSED RACEWAYS SHALL BE RIGID GALVANIZED STEEL.
13. DEVICE LOCATIONS AS DESIGNATED ON THE ELECTRICAL PLANS ARE
DIAGRAMMATIC. FINAL LOCATIONS SHALL BE DETERMINED BY FIELD
CONDITIONS.
14. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER
CONDUCTORS, AS NOTED IN SPECIFICATIONS, WITHIN RACEWAYS.
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS
2. REFER TO DRAWING G-002 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS
3. REFER TO DRAWING E-501 FOR ELECTRICAL LEGEND.
4. REFER TO TECHNICAL SPECIFICATIONS FOR ADDITIONAL ELECTRICAL
PROJECT REQUIREMENTS.
GENERAL SHEET NOTES
PR
PO
SE
D M
C C
O N
E-
LI
N E
EL
EC
TR
IC
AL
4603.017
A
B
2 3
C
D
1 2 3
4 5 6
PROJECT NO.
APPROVED BY:
SCALE:
CHECKED BY:
PREPARED BY:
A
B
D
AT
E R
EV
4 5
IS
SU
ED
F
O R
/R
EV
IS
ED
C
AP
PD
D
DRAWING NO.
Entech Engineering - Printed: Jan. 16, 2026 H:\0004603.017\04-CAD\SheetFiles\E-601.dwgLa st
E di te d by : A
A tti ck
E-601
PO
R
TE
R
T O
W
ER
J O
IN
T
M U
N
IC
IP
AL
A U
TH
O
R
IT
Y
TO
W
ER
C
IT
Y, S
C H
U
YL
KI
LL
C O
U N
TY
, P
EN
N
SY
LV
AN
IA
W W
TP
IN
FL
U
EN
T
PU
M
P
IM
PR
O
VE
M
EN
TS
AS NOTED
JED
DEM
DEM
/1
6/
D
BI
D
D
IN
G
BJ
M
P
E N N S Y L V A N
I A056260NO.
DAVID E. MACE
C O
M
M O N W E A L T H
O F
ENGINEER
PROFESSIONAL
REGISTERED
FEED FROM PANEL 'OPH'
MAIN
LUGS
1A
SECTION #1 SECTION #2
MOTOR CONTROL CENTER MCC-100
1B 1C 1D 2A 2D 2E
SECTION #3
3P/
XXA
3P/
XXA
3A 3B 3C 3D
SECTION #4
3P/
XXA
3P/
XXA
4A 4B 4C 4D
OUTPUT
FILTER
SECTION #5
5A 5B 5C 5D
CP-100 CP-120
CONDUCTOR SIZE KEY-
a. PROVIDE (3) #6 & (1) #8 GRD, 1"C.
GENERAL SHEET NOTES
3P/ 40A
CB
JOCKEY
PUMP
P-123
VFD
W/BYP.
3P/ 60A a a
LINE
REACTOR
OUTPUT
FILTER
SHEET KEYNOTES
1. PROVIDE NEW, NEMA 12/4X STAINLESS STEEL, 3P/60A NON-FUSIBLE
DISCONNECT SWITCH FOR LOCAL LOCK-OUT OF MOTOR. WHERE
USED ON VFD-CONTROLLED MOTOR - PROVIDE AUX CONTACT, WIRED
TO BREAK BEFORE BLADES OPEN - TO DROP OUT VFD PRIOR TO
OPENING MOTOR LEADS
2. COORDINATE WITH SQUARE D TO FURNISH AND INSTALL ONE (1) 15 HP
VFD WITH ASD-RATED LINE REACTOR AND ASD OUTPUT FILTER,
LOCATED IN MCC-100. PROVIDE ALL ACCESSORIES FOR A COMPLETE,
CODE-COMPLIANT, COMMISSIONED INSTALLATION.
3. RUN POWER CONDUIT FROM MCC-100 (LOCATED IN OPERATIONS
BUILDING UPPER LEVEL PLAN) TO P-123 DISCONNECT IN OPERATIONS
BUILDING INTERMEDIATE LEVEL PLAN (REFER TO SHEET E-102).
PROVIDE NEW NEMA 12/4X STAINLESS STEEL, 3-POLE, 60A
NON-FUSIBLE DISCONNECT SWITCH FOR LOCAL LOCKOUT OF MOTOR.
WHERE USED ON VFD-CONTROLLED MOTOR, PROVIDE AUXILIARY
CONTACT WIRED TO BREAK BEFORE BLADES OPEN TO DROP OUT VFD
PRIOR TO OPENING MOTOR LEADS.
3.1. THIS INSTALLATION WILL REQUIRE NEW CONDUIT. CONDUIT SHALL
BE FIELD ROUTED DUE TO MULTIPLE OBSTRUCTIONS IN THE AREA.
A TOTAL OF FOUR (4) CONDUITS SHALL BE PROVIDED FROM
MCC-100 AS FOLLOWS:
• ONE (1) CONDUIT FOR POWER AND AUX CONTACT TO THE P-123
DISCONNECT.
• ONE (1) CONDUIT FOR CONTROL WIRING TO THE WET WELL
CONTROL PANEL (WWCP).
• ONE (1) CONDUIT FOR DATA WIRING TO THE WET WELL CONTROL
PANEL (WWCP).
• ONE (1) SPARE CONDUIT TO THE WET WELL CONTROL PANEL
(WWCP).
3.2. ALL CONDUITS SHALL BE SIZED PER NEC REQUIREMENTS AND
PROJECT SPECIFICATIONS. PROVIDE RIGID PVC OR STAINLESS
STEEL CONDUIT AS APPROPRIATE FOR THE INSTALLATION
ENVIRONMENT. INSTALL IN ACCORDANCE WITH NEC AND PROJECT
STANDARDS
1. REFER TO DRAWING G-001 FOR GENERAL PROJECT NOTES, DRAWING
INDEX, DRAWING CONVENTIONS AND MAPS.
2. REFER TO DRAWING G-003 FOR DRAWING LEGENDS, SYMBOLS AND
ABBREVIATIONS.
| Sheets and Views |
| 4 G-001 - G-001 |
| 4mvplot |
| G-002 - 24x36 |
| 5 G-101 - Layout1 |
| G-601 - Layout1 |
| GED-401 - 24x36 |
| 1 D-101 - 24x36 |
| 3 D-301 - 24x36 |
| D-501 - 24x36 |
| E-101 - 24x36 |
| 4mvplot |
| E-102 - 24x36 |
| 4mvplot |
| E-501 - 24x36 |
| 4mvplot |
| E-502 - 24x36 |
| 4mvplot |
E-601 - 24x36
File details come from the government source that posted it. Updated .