(2) WD-06-26_Cherry Ave Sewer Design Plans (SIGNED).pdf
PDF 8 MB Posted
- Solicitation number
- UD-26-361
- Issued by
- Los Angeles County, California
About this file
This document consists of construction plans for the Cherry Avenue Sewer Improvement Project (WD-06-26, Drawing File Number SC-0512) prepared by the Long Beach Public Utilities Department in Long Beach, California, with engineering services provided by DRP Engineering, Inc. under Project Manager Saik-Choon Poh. The project encompasses sewer main construction and rehabilitation work across multiple segments: Gardenia Avenue from Station 30+02 to Station 32+98, East Anaheim Street from Station 10+02 to Station 11+00 and Station 11+00 to Station 13+08, and Cherry Avenue from Station 49+82 to Station 52+00 through Station 68+00 to Station 74+55. The work involves removal and replacement of existing sewer lines with new vitrified clay pipe (VCP) and high-density polyethylene (HDPE) pipe of varying diameters (8-inch to 18-inch), construction of 48-inch and 60-inch diameter maintenance holes, installation of new sewer service laterals, and connection to existing Los Angeles County Sanitation Districts (LACSD) facilities. The plans were submitted in September 2026 and approved by Thomas Berele, Senior Director of Engineering, on September 15, 2026.
The plans establish comprehensive construction requirements and specifications for contractor performance, including traffic control measures maintaining minimum one-lane operation during construction, work hours from 7:00 a.m. to 4:00 p.m. on weekdays, mandatory pre-construction conferences, and provisions for sewer bypass operations to maintain service continuity. Contractors must comply with LACSD standard specifications and amendments, coordinate with utility companies for underground facility locating, obtain necessary permits from the City of Long Beach and Cal-OSHA, and maintain detailed video documentation of completed work. The project requires coordination with multiple utility providers including Southern California Edison, Verizon, AT&T, MCI, Spectrum, and the City of Long Beach departments. Backfill specifications allow for native earth with sand-cement slurry as an alternative, and compaction testing must be coordinated with Long Beach Public Utilities Department inspection staff and performed by certified laboratories. All sewer lines are specified as extra-strength VCP unless otherwise noted, with flexible joints required within 18 inches of LACSD manhole connections.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1111 Corporate Center Dr Suite 303, Monterey Park
CA 91754
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
N/ASCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
DN
CDR SEP/26
N/A
WD-06-26
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT CHERRY AVE SEWER
IMPROVEMENT PROJECT WASM KV
GENERAL
TITLE SHEET
LONG BEACH PUBLIC UTILITIES DEPARTMENT
LONG BEACH, CALIFORNIA
PLANS FOR THE CONSTRUCTION OF
GENERAL MANAGER
B. ANATOLE FALAGÁN
WD-06-26
THOMAS BEKELE - SENIOR DIRECTOR OF ENGINEERING DATE
LONG BEACH PUBLIC UTILITIES DEPARTMENT
APPROVED BY:
CHERRY AVENUE SEWER
IMPROVEMENT PROJECT
SEPTEMBER 2026
SUBMITTED BY:
DRP Engineering, Inc.
PROJECT MANAGER:
SAIK-CHOON POH R.C.E. 69223 DATE
COUNTY SANITATION DISTRICT NO. 2
OF LOS ANGELES COUNTY, CALIFORNIA
ROBERT C. FERRANTE - CHIEF ENGINEER AND GENERAL MANAGER
APPROVED BY: _______________________
OFFICE ENGINEER
DATE: ___________
S A
I K
- C H O O N P
O H
9/15/2026
9/11/2026
ROAD CENTERLINE AND STREET NAME
RIGHT-OF-WAY
LOT
CURB
EXISTING STORM DRAIN LINE, SDMH, AND SD CATCH BASIN
RIGHT-OF-WAY ADDITIONAL TAKE
DETAIL NUMBER
SHEET NUMBER10
SHEET BOUNDARY
HOUSE NUMBER AND WATER METER INFO
WATER ATLAS REFERENCE
N28 N27
SEWER MAINTENANCE HOLE
FIRE HYDRANT
WATER VALVE
STREET LIGHT
TRAFFIC CONTROL LOOP
CONNECTION DETAIL NUMBER
DRAWING NUMBER
VICINITY MAP
SHEET INDEX
SHEET NO.
1 G-001 TITLE SHEET
2 G-002 SHEET INDEX, VICINITY MAP & GENERAL NOTES
3 G-003 GENERAL NOTES, LEGEND AND SURVEY NOTES
4 G-004 ABBREVIATIONS, LACSD CONNECTION NOTES AND
PUBLIC AGENCIES
5 C-001 PLAN AND PROFILE
GARDENIA AVE - STA 30+02 TO STA 32+98 &
E ANAHEIM ST - STA 10+02 TO STA 11+00
6 C-002 PLAN AND PROFILE
E ANAHEIM ST - STA 11+00 TO STA 13+08 &
CHERRY AVE - STA 49+82 TO STA 52+00
DESCRIPTION
1111 Corporate Center Dr Suite 303, Monterey Park
CA 91754
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
N/ASCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
DN
CDR SEP/26
N/A
WD-06-26
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT CHERRY AVE SEWER
IMPROVEMENT PROJECT WASM KV
LOCATION MAP
SYMBOLS
NOTE TO CONTRACTOR
SHEET INDEX, VICINITY MAP
& GENERAL NOTES
SHEET NO.
7 C-003 PLAN AND PROFILE
CHERRY AVE - STA 52+00 TO STA 60+00
8 C-004 PLAN AND PROFILE
CHERRY AVE - STA 60+00 TO STA 68+00
9 C-005 PLAN AND PROFILE
CHERRY AVE - STA 68+00 TO STA 74+55
10 C-006 MISCELLANEOUS DETAILS
11 C-007 CONNECTION DETAILS
DESCRIPTION
THE EXISTENCE AND LOCATIONS OF ALL UNDERGROUND UTILITIES (UTILITIES, PIPES, STRUCTURES, ETC.)
SHOWN ON THE PLANS ARE APPROXIMATE AND WERE ASCERTAINED BY A REVIEW OF RECORDS
PROVIDED BY UTILITY COMPANIES. NEITHER THE OWNER NOR THE ENGINEER ASSUMES ANY
RESPONSIBILITY FOR UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN. THE CONTRACTOR SHALL
DETERMINE THE DEPTH AND LOCATION OF UNDERGROUND FACILITIES PRIOR TO THE START OF
CONSTRUCTION AND SHALL BE REQUIRED TO TAKE ANY PRECAUTIONARY MEASURES TO PROTECT ALL UTILITIES SHOWN AND/OR ANY OTHER UNDERGROUND UTILITY NOT OF RECORD OR NOT SHOWN ON THE
PLANS.
K13 K12
K12 L12
K12 L11
CONSTRUCTION NOTES
CONSTRUCT 10-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
CONSTRUCT 12-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD. DWG WDS-511
9 CONSTRUCT 48-INCH DIAMETER MAINTENANCE HOLE PER LBUD STD. DWG WDS-502
REMOVE EXISTING 15-INCH SEWER MAIN AND CONSTRUCT 18-INCH VITRIFIED CLAY PIPE (VCP), EXTRA
STRENGTH WITH COMPRESSION JOINTS AND ENCASED
4 REMOVE EXISTING 10-INCH SEWER MAIN AND CONSTRUCT 12-INCH VITRIFIED CLAY PIPE (VCP), EXTRA
STRENGTH WITH COMPRESSION JOINTS
10 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND RELINE MAINTENANCE HOLE
11 PROTECT IN PLACE EXISTING MAINTENANCE HOLE
12 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND CONNECT TO EXISTING LACSD MH #03 0317
PER CONNECTION DETAIL A ON DRAWING C-001
REPLACE EXISTING HOUSE CONNECTION WITH NEW LATERAL PER LBUD STD DWG WDS-506 MODIFIED ON SHEET C-6, AND REPLACE LATERAL UP TO AND MAKE RECONNECTION AT THE PROPERTY LINE
17 CONSTRUCT 60-INCH DIAMETER DROP MAINTENANCE HOLE PER LBUD STD. DWG WDS-503
3 REMOVE EXISTING 8-INCH SEWER MAIN AND CONSTRUCT 10-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
13 ABANDON EXISTING MAINTENANCE HOLE PER DETAIL 2 ON SHEET 10
14 ABANDON EXISTING SEWER PIPELINE
15 REMOVE EXISTING MAINTENANCE HOLE
16 REMOVE EXISTING SEWER PIPELINE
18 CONSTRUCT COMPRESSIBLE BLANKET FOR UTILITY CROSSING PER DETAIL 4 ON SHEET 10
19 CONSTRUCT 10" HDPE SDR-21 (FUSION WELDED JOINTS) PIPE WRAPPED WITH POLYETHYLENE
LINER PPL-24 OR APPROVED EQUAL. POLYETHYLENE LINER SHALL BE HEAT WELDED
S A
I K
- C H O O N P O
H
GENERAL NOTES
OIL PIPELINES
TRAFFIC SIGNAL CONDUITS
SO. CAL EDISON CONDUITS
ENERGY RESOURCES
TELEPHONE CONDUITS (VERIZON/AT&T)
SANITARY SEWER
WASTE WATER
POTABLE WATER
UNDERGROUND UTILITY LEGEND
STREET LIGHT CONDUITS
STORM DRAIN
POTABLE WATER (ABANDONED)
PROPOSED SEWER
1111 Corporate Center Dr Suite 303, Monterey Park
CA 91754
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
N/ASCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
DN
CDR SEP/26
N/A
WD-06-26
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT CHERRY AVE SEWER
IMPROVEMENT PROJECT WASM KV
GENERAL NOTES, LEGEND
AND SURVEY NOTES
THE BASIS OF HORIZONTAL CONTROL FOR THIS PROJECT IS CALIFORNIA COORDINATE
SYSTEM NAD83 ZONE 5, (2010.00) DETERMINED LOCALLY BY THE FOLLOWING N.G.S.
CONTINUOUS OPERATING REFERENCE STATIONS (C.O.R.S):
N.G.S. C.O.R.S TORP:
NORTHING = 1748960.10' EASTING = 6461222.47'
N.G.S. C.O.R.S VDCY:
NORTHING = 1887437.07' EASTING = 6495130.69'
THE COMBINATION FACTOR FOR THIS PROJECT WAS APPLIED AT THE FOLLOWING POINT:
NORTHING = 1741959.57' EASTING = 6510742.98'
MAPPING ANGLE = -0°05'44" SCALE FACTOR = 0.99993128
BENCHMARK
ELEVATIONS SHOWN HEREON ARE BASED UPON CITY OF LONG BEACH BENCHMARK
22, ELEVATION 30.90 FEET (NAVD 88).
DESCRIPTION:
CORNER NE CHERRY AVE @ ANAHEIM ST
BRASS DISC FLUSH W/ PVMT; STAMPED "CLB BM 22
RE 3111 1970" 16.3' E / CURB; 1.1' N / CURB
BASIS OF BEARING
1. CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY
ACCEPTED CONSTRUCTION PRACTICES, CONTRACTOR WILL BE
REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR
JOB SITE CONDITIONS DURING THE COURSE OF THE CONSTRUCTION
OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS
AND CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND
HOLD HARMLESS THE CITY, LONG BEACH PUBLIC UTILITIES
DEPARTMENT (LBUD), ITS EMPLOYEES, AGENTS AND DRP
ENGINEERING FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN
CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF
THE STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION,
AND IN ACCORDANCE WITH THE CITY OF LONG BEACH AMENDMENTS
TO STANDARD SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION
(LATEST EDITION), LONG BEACH PUBLIC UTILITIES DEPARTMENT
WATER AND SEWER STANDARDS, ALL APPLICABLE AMERICAN WATER
WORKS ASSOCIATION (AWWA) STANDARDS, ALL APPLICABLE
NATIONAL ASSOCIATION OF SEWER SERVICE COMPANIES (NASSCO),
AND IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS, ALL
TO THE SATISFACTION OF THE LONG BEACH UTILITIES DEPARTMENT.
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT
DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS IMMEDIATELY
TO THE OWNER'S REPRESENTATIVE FOR RESOLUTION PRIOR TO
CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR DISCREPANCIES
NOT SO REPORTED AND RESOLVED.
4. THE CONTRACTOR SHALL PERFORM A UTILITY SEARCH FOR THE
PROJECT AREAS TO IDENTIFY ALL UTILITIES INCLUDING ONES NOT
SHOWN ON PLANS. THE CONTRACTOR IS REQUIRED TO TAKE ALL
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES SHOWN,
AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE
PLANS, AND IS RESPONSIBLE FOR ANY DAMAGE TO THESE LINES OR
STRUCTURES. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY EACH RESPECTIVE UTILITY AND UNDERGROUND SERVICE
ALERT OF SOUTHERN CALIFORNIA, 811 TO DETERMINE THE EXACT
FIELD LOCATION OF UTILITIES WHICH MAY CONFLICT WITH THE
WORK.
5. THE CONSTRUCTION DRAWINGS SHOW THE GENERAL LOCATION AND
DEPTH OF UNDERGROUND UTILITIES BASED ON THE BEST
INFORMATION AVAILABLE TO LBUD. LBUD DOES NOT GUARANTEE
THE LOCATION OR DEPTH OF UNDERGROUND UTILITIES AND IT
SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIND THE EXACT
LOCATION AND DEPTH OF UNDERGROUND UTILITIES IN AREAS
REQUIRING EXCAVATION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO
EXISTING UTILITIES, PAVEMENT, SIDEWALKS, PARKWAYS, CURBS,
TRAFFIC STRIPING, MARKER AND MARKINGS, TRAFFIC SIGNAL
DETECTOR LOOPS, STREET LIGHT CONDUITS, STRUCTURES, TREES,
AND IRRIGATION SYSTEMS AS A RESULT OF HIS OPERATION AND
WILL BE REQUIRED TO REPAIR OR REPLACE SAME TO THE
SATISFACTION OF AND AS DIRECTED BY, LONG BEACH UTILITY
DEPARTMENT, LOS ANGELES COUNTY FLOOD CONTROL DISTRICT,
THE ENGINEER, UTILITY COMPANY OR PROPERTY OWNER.
7. THE CONTRACTOR SHALL HAVE COPIES OF THE PLANS AND
SPECIFICATIONS FOR THE PROJECT ON THE PROJECT SITE AT ALL
TIMES, AND HE SHALL BE FAMILIAR WITH ALL APPLICABLE
STANDARDS AND SPECIFICATIONS.
8. SANITARY FACILITIES SHALL BE MAINTAINED ON THE SITE.
9. THE CONTRACTOR SHALL COOPERATE WITH CONTRACTORS
PERFORMING OTHER CONSTRUCTION WORK IN AREAS ADJACENT TO
THE PROJECT SITE.
10. THE CONTRACTOR SHALL MAINTAIN DUST CONTROL AT ALL TIMES.
DUST SHALL BE CONTROLLED PER SPECIFICATION 01 50 00.
11. THE WALLS AND FACE OF ALL EXCAVATION FIVE (5) FEET OR
GREATER IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A SHORING
SYSTEM, SLOPING OF THE GROUND, OR OTHER EQUIVALENT MEANS.
TRENCHES OR EXCAVATION LESS THAN FIVE (5) FEET IN DEPTH
SHALL BE GUARDED WHEN EXAMINATION BY A COMPETENT PERSON
INDICATED THAT HAZARDOUS GROUND MOVEMENT MAY BE
EXPECTED. THE CONTRACTOR SHALL OBTAIN A PERMIT TO PERFORM
EXCAVATION OR TRENCH WORK AS DESCRIBED FROM CAL-OSHA.
12. STREET PAVING SHALL BE PER PLANS, SPECIFICATIONS, LBUD STD
DWG WDS-406, UNLESS OTHERWISE STATED OR DIRECTED BY LBUD.
13. A MAXIMUM OF 500 LINEAL FEET OF STEEL TRENCH PLATES SHALL BE
USED ON THE PROJECT AT ANY GIVEN TIME. GRIND PAVEMENT
UNDER EDGES OF STEEL TRENCH PLATES TO RECESS TRENCH
PLATES FLUSH WITH PAVEMENT, TEMPORARY STEEL PLATE
BRIDGING PER LBUD STD DWG WDS-128.
14. STREET CENTERLINE AND SURVEY MONUMENTS THAT MUST BE
REMOVED FOR CONSTRUCTION SHALL BE REPLACED BY A
CALIFORNIA LICENSED LAND SURVEYOR, OR PROTECTED IN PLACE.
15. BACKFILL TRENCH ZONE WITH NATIVE EARTH BACKFILL OR
IMPORTED BACKFILL PER SPECIFICATION SECTION 31 23 33 -
TRENCHING AND BACKFILLING. INSTALL SAND-CEMENT SLURRY
BACKFILL WHERE NOTED ON PLANS. THE CONTRACTOR HAS THE
OPTION OF BACKFILLING WITH SAND-CEMENT SLURRY IN LIEU OF
NATIVE OR IMPORTED MATERIALS AT HIS DISCRETION ELSEWHERE.
16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE
EXISTING SEWER MAIN IN SERVICE DURING CONSTRUCTION AND
SHALL SUBMIT A SEWER BYPASS PLAN FOR APPROVAL BY LBUD
PRIOR TO CONSTRUCTION. THE BYPASS PLAN SHALL INCLUDE
TEMPORARY TRAFFIC CONTROL. TRAFFIC CONTROL SHALL BE
MAINTAINED AT ALL TIMES AND SHALL BE PROTECTED WITH
ADEQUATE BARRICADES, LIGHTS, SIGNS AND WARNING DEVICES,
PER THE CORRECT STATE OF CALIFORNIA DEPARTMENT OF
TRANSPORTATION MANUAL OF TRAFFIC CONTROLS AND PER THE
DIRECTION OF THE CITY OF LONG BEACH PUBLIC WORKS.
17. IF GROUNDWATER IS ENCOUNTERED, CONTRACTOR SHALL BE
RESPONSIBLE FOR DEWATERING ACCESS PITS AND TRENCHES AND
DISPOSING OF WATER AS REQUIRED BY THE CONTRACT DOCUMENTS
AND APPLICABLE NPDES PERMITS AND FEDERAL, STATE, AND LOCAL
GOVERNMENT REQUIREMENTS. FOR THE PURPOSE OF PREPARING
BIDS AND DEWATERING PLANS, CONTRACTOR SHALL ASSUME
GROUNDWATER TO BE PRESENT 10' BELOW GROUND SURFACE.
18. PROVIDE TRAFFIC CONTROL AS NEEDED PER THESE TRAFFIC
CONTROL PLANS AND THE CITY OF LONG BEACH STANDARD PLAN
340-386. MAINTAIN PUBLIC ACCESS ON PUBLIC STREETS AND SAFETY
AROUND CONSTRUCTION SITE. IF ANY OF THE PROPOSED WORK
REQUIRES TRAFFIC CONTROL CONFIGURATIONS NOT SHOWN ON
THESE PLANS, THE CONTRACTOR'S BID SHALL INCLUDE THIS WORK
AS PART OF THE TOTAL BID PRICE.
19. ALL CONCRETE PAVING, INCLUDING SIDEWALKS, CURBS AND
GUTTERS REQUIRING REMOVAL, SHALL BE SAWCUT AND REPLACED
IN KIND TO THE NEAREST CONSTRUCTION JOINT.
20. THE CONTRACTOR SHALL PROVIDE FOR PUBLIC SAFETY AND
CONVENIENCE DURING ALL PHASES OF THE WORK, CONTRACTOR
SHALL ESTABLISH ADEQUATE ACCESS TO ALLEYS AND GARAGES AT
THE END OF EACH WORKING DAY TO THE SATISFACTION OF THE CITY
OF LONG BEACH AND LBUD. CONTRACTOR WILL ALSO
ACCOMMODATE GARBAGE TRUCK ACCESS ON ALL PICKUP DAYS.
21. SERVICE LATERALS CROSSING THE PIPELINE HAVE NOT BEEN
SHOWN ON THE PIPELINE PROFILES, THE CONTRACTOR SHALL
ASSUME EACH HOUSE OR BUSINESS WILL HAVE THE FOLLOWING
SERVICES CROSSING THE PIPELINE: WATER, SEWER, GAS, AND
ELECTRIC. THE CONTRACTOR SHALL TAKE ADEQUATE MEASURES TO
PROTECT THE EXISTING SERVICE LATERALS.
22. TRAFFIC LOOPS HAVE BEEN SHOWN ON THE PLANS BASED ON THE
BEST AVAILABLE INFORMATION. THE CONTRACTOR'S BID SHALL
ASSUME ALL AFFECTED TRAFFIC LOOPS AND ASSOCIATED CONDUIT
(SHOWN OR NOT SHOWN ON THE PLANS MUST BE REPLACED AS
PART OF THE PROJECT.
23. JETTING SHALL NOT BE ALLOWED UNDER ANY CIRCUMSTANCES.
24. CENTERLINES AND RIGHT-OF-WAY LINES SHOWN ARE BASED ON LOS
ANGELES COUNTY ASSESSORS MAPS AND INFORMATION PROVIDED
BY LONG BEACH PUBLIC UTILITIES DEPARTMENT.
25. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF ONE TRAFFIC
LANE IN EACH DIRECTION DURING CONSTRUCTION. FULL STREET
CLOSURE MAY BE ALLOWED IF CONTRACTOR OBTAINS APPROVAL
FROM LBUD AND CITY OF LONG BEACH. CONTACT LONG BEACH
TRANSIT AT (562) 599-8570 PRIOR TO CLOSING ANY BUS STOPS PER
SPECIFICATION 01 55 26.
26. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, LOCAL
AND CAL/OSHA SAFETY REGULATIONS. THE CONTRACTOR'S
PERSONNEL SHALL BE CERTIFIED FOR CONFINED SPACE ENTRY.
27. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND
DISPOSAL OF ALL DEBRIS REMOVED DURING THE SEWER MAIN
CLEANING AND REHABILITATION PROCESS. THE CONTRACTOR SHALL
COMPLY WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS
REGARDING DISPOSAL OF DEBRIS.
28. CONTRACTOR SHALL USE EXTREME CAUTION WORKING NEAR
OVERHEAD UTILITIES.
29. ALL SEWER LINES CONSTRUCTED SHALL BE EXTRA STRENGTH VCP
BELL AND SPIGOT UNLESS NOTED OTHERWISE.
30. THE CONTRACTOR SHALL BE FAMILIAR WITH THE PROJECT'S
GEOTECHNICAL EVALUATION REPORT TITLED "GEOTECHNICAL
EVALUATION: CHERRY AVENUE SEWER IMPROVEMENT PROJECT
(SC-0512)" BY SOCOTEC, DATED JULY 15, 2026.
31. CONTRACTOR SHALL SET ALL MAINTENANCE HOLE FRAMES AND
COVERS TO FINISH GRADE (AFTER PLACING FINAL LIFT OF ASPHALT).
32. PRIOR TO FINAL ACCEPTANCE, THE CONTRACTOR SHALL PROVIDE A
PRECONSTRUCTION AND POST CONSTRUCTION DVD VIDEO RECORD
OF ALL SEWER MAINS, WHICH INCLUDES A LOG OF ALL
CONSTRUCTIONS AND MAINTENANCE HOLE.
33. 48 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION
ACTIVITIES, CONTRACTOR TO ARRANGE FOR FIELD MARKINGS OF
PLANS FACILITIES. THIS NOTIFICATION IS IN ADDITION TO
NOTIFICATION THROUGH UNDERGROUND SERVICE ALERT.
34. CONTRACTOR SHALL OBTAIN REQUIRED PERMITS INCLUDING, BUT
NOT LIMITED TO, THOSE FROM THE CITY OF LONG BEACH, CAL-OSHA,
AND OTHERS AS REQUIRED, SEE PROJECT SPECIFICATIONS.
35. CONSTRUCTION SHALL NOT BEGIN UNTIL AFTER A
PRE-CONSTRUCTION CONFERENCE IS HELD AT LEAST ONE WEEK
PRIOR TO ANY CONSTRUCTION. IN ADDITION, LONG BEACH PUBLIC
UTILITIES DEPARTMENT SHALL BE NOTIFIED A MINIMUM OF 48 HOURS
PRIOR TO ANY CONSTRUCTION ACTIVITIES. CONTACT LONG BEACH
PUBLIC UTILITIES DEPARTMENT CHIEF CONSTRUCTION INSPECTOR
ANGEL MARQUEZ AT 562-244-9334 48 HOURS PRIOR TO
CONSTRUCTION ACTIVITIES.
36. COMPACTION TESTS SHALL BE COORDINATED BY LONG BEACH
PUBLIC UTILITIES DEPARTMENT INSPECTION STAFF AND PERFORMED
BY A CERTIFIED LABORATORY AS DESCRIBED IN THE
SPECIFICATIONS. CONTRACTOR IS RESPONSIBLE TO NOTIFY LONG
BEACH PUBLIC UTILITIES DEPARTMENT 48 HOURS IN ADVANCE FOR
SCHEDULING TESTING.
37. THE CONTRACTOR IS TO PROVIDE THE LONG BEACH UTILITIES
DEPARTMENT WITH A "RECORD DRAWING" SET OF JOB PRINTS WITH
TIE-DOWN MEASUREMENTS FOR ALL LATERALS AND MAINTENANCE
HOLE.
38. THE CONTRACTOR SHALL MAINTAIN THE WORK AREA IN A NEAT,
SAFE, CLEAN, AND SANITARY CONDITION AT ALL TIMES, AND TO THE
SATISFACTION OF THE LONG BEACH UTILITIES DEPARTMENT AND
THE CITY OF LONG BEACH. STREETS SHALL BE KEEP FREE OF
DEBRIS, WITH DUST AND NUISANCE BEING CONTROLLED AT ALL
TIMES. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR ANY
CLEANUP ON ADJACENT STREETS AFFECTED BY HIS CONSTRUCTION.
CONTRACTOR TO CLEAN STREET WITH SWEEPER PRIOR TO END OF
EACH WORK DAY AT A MINIMUM.
39. CONSTRUCTION WORK HOURS SHALL BE FROM 7:00 A.M. TO 4:00 P.M.
EXCLUSIVE OF SATURDAYS, SUNDAYS OR HOLIDAYS, EXCEPT AS
MODIFIED BY THE APPROVED TRAFFIC CONTROL PLANS OR CITY
PERMITS. REFER TO SPECIFICATIONS FOR CONSTRUCTION WORK
HOURS INVOLVING LANE CLOSURE OR BLOCKAGE WITHIN PAVED
RIGHT-OF-WAY. CONTRACTOR CAN PROPOSE TO PERFORM
NIGHTWORK, BUT WILL REQUIRE APPROVAL FROM LBUD AND THE
CITY OF LONG BEACH.
40. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT
(DIG ALERT) AT LEAST TWO WORKING DAYS, BUT NOT MORE THAN 14
DAYS PRIOR TO ANY EXCAVATION.
41. ALL CONSTRUCTION ACTIVITIES SHALL COMPLY WITH THE CURRENT
CITY OF LONG BEACH NOISE REGULATIONS AS DEFINED IN THE LONG
BEACH MUNICIPAL CODE CHAPTER.
PROPOSED SEWER LATERAL
S A
I K
- C H O O N P O
H
(LACSD) GENERAL NOTES
1. NO CONNECTION FOR THE DISPOSAL OF INDUSTRIAL WASTES SHALL BE MADE TO SEWERS
SHOWN ON THESE PLANS UNTIL A PERMIT FOR INDUSTRIAL WASTEWATER DISCHARGE HAS
BEEN ISSUED BY LACSD FOR SAID CONNECTION.
2. LACSD WILL NOT OWN/OPERATE ANY FACILITIES SHOWN ON THE PLANS UNLESS ALREADY
OWNED BY LACSD OR UNLESS OTHERWISE SPECIFIED OR NOTED ON THESE PLANS.
3. SEE LACSD MANHOLE DETAIL ON THESE SEWER PLANS.
4. ALL WORK INVOLVING LACSD SEWERS OR MANHOLES SHALL BE IN ACCORDANCE WITH THE
LATEST APPROVED EDITION OF THE "STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION" (GREENBOOK) AND LACSD "AMENDMENTS TO THE STANDARD SPECIFICATIONS
FOR PUBLIC WORKS CONSTRUCTION AND STANDARD DRAWINGS FOR CONSTRUCTION". AN
ELECTRONIC COPY OF THE AMENDMENTS AND STANDARD DRAWINGS CAN BE DOWNLOADED
FROM THE LACSD WEBSITE AT WWW.LACSD.ORG.
5. LACSD IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE RELATING TO
THE WORK ON THESE SEWER PLANS. THE PROJECT OWNER SHALL INDEMNIFY AND HOLD
HARMLESS LACSD FROM ANY CLAIMS, DAMAGE OR LOSSES RELATING TO THE WORK ON THESE
SEWER PLANS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO LACSD FACILITIES AT ITS
EXPENSE.
LOS ANGELES COUNTY SANITATION DISTRICTS
ABBREVIATIONS
P
LONG RADIUS
POWER
VERT
FIRE HYDRANT FH
LAT
HIGHPOINT
HYD HYDRANT
HP
LATERAL
WJ
SCH
SD
SS
SHT
SCE
S
R/W OR ROW
VCP
UG
TS
TYP
STA
STD
STL
HORIZONTAL
LF
M
MG
GALV
IRR
LBUD
MIN
NTS
OC
OD
NAP
MJ
MH
MV
ID
HMW/PE HIGH MOLECULAR WEIGHT
GB
POLYETHYLENE
HORIZ
INSUL INSULATION
GRADE BREAK
H
HWY
GV
G
MW MONITORING WELL
GA
SERVICE
STORM DRAIN
SCHEDULE
SHEET
SANITARY SEWER
SIGNAL
SOUTHERN CALIFORNIA EDISON
RADIUS
REQUIRED
REINFORCED CONCRETE PIPE
POINT OF VERTICAL INTERSECTION
SLOPE (GRADIENT OF PIPELINE)
RECYCLED WATER
RIGHT-OF-WAY
PUBLIC WORKS CONSTRUCTION
VITRIFIED CLAY PIPE
UNDERGROUND
UNKNOWN
VERTICAL
WATER SERVICE
WELDED JOINTS
TYPICAL
STANDARD
STATION
STANDARD SPECIFICATIONS FOR
STEEL
TRAFFIC SIGNAL CONDUIT
TOP OF PIPE
TELEPHONE
REINFORCED CONCRETE BOX
UNK
PRC
PT
TOP
SSPWC
WS
PVC
RJ
REQ'D
RW
RCP
PVMT
R
RCB
TEL
POLYVINYL CHLORIDE
POINT OF REVERSE CURVE
PP
PAVEMENT
RESTRAINED JOINT
POINT
POWER POLE
RSGV
PVI
SIG/SL
PI
PL
CONC
BF
BFV
DC
CI CML
CML&C
BOP
BO
CI
CO
CP
C
APPROX
AIR-VAC
BC
AWG
BEGIN CURVE
BLIND FLANGE
BEGIN VERTICAL CURVE
APPROXIMATE
AIR RELEASE & VACUUM RELIEF VALVE
BLOW-OFF ASSEMBLY
BUTTERFLY VALVE
FL
COND
DI
C&G
DET
FLG
ASSY
BFP
CB
ACP
ASPHALT CONCRETE OR ASBESTOS CEMENT
AGGREGATE BASE AB
ABANDONED
AC
FG FINISHED GRADE
PLASTIC LINE
POINT OF INTERSECTION
FINISHED FLOOR FF
ABN OR ABD
EC
DIP
DIA
E OR ELEC
BVC
LC
DWG
EVC
ESMNT
FO
CS
F
EX
NOT TO SCALE
NOT A PART
ON CENTER
METERING VAULT
GALVANIZED
METER
MINIMUM
NOT IN CONTRACT
MAINTENANCE HOLE
POINT OF COMPOUND CURVE
PLAIN END
MILLION GALLONS
MECHANICAL JOINT
OUTSIDE DIAMETER
LINEAR FEET
HIGHWAY
FUT
FINISHED SURFACE
FUTURE
FS
NIC
PCC
PE
GAUGE
LONG BEACH PUBLIC UTILITIES DEPARTMENT
GATE VALVE
IRRIGATION
GAS
HOUSE
INSIDE DIAMETER
FLANGE
CEMENT MORTAR LINED AND COATED
CAST IRON CEMENT MORTAR LINED
CAST IRON
CLEAN OUT (SEWER)
CONCRETE PIPE
CONDUIT
CONCRETE
CATCH BASIN
BACK FLOW PREVENTER
AMERICAN WIRE GAUGE
BOTTOM OF PIPE
ASSEMBLY
CURB AND GUTTER
COPPER PIPE
ASBESTOS CEMENT PIPE
CORPORATION STOP
END VERTICAL CURVE
EASEMENT
END CURVE
EXISTING
FLOWLINE
FLARE
FIBER OPTICS
ELECTRIC
DETAIL
DOUBLE CHECK DETECTOR ASSEMBLY
CENTERLINE
DUCTILE IRON
DRAWING
DUCTILE IRON PIPE
DIAMETER
RESILIENT SEATED GATE VALVE
LR
NRCP NON-REINFORCED CONCRETE PIPE
SERV
CL/
INVERT ELEVATION IE/INV (EL)
FM FORCE MAIN
PH POTHOLE
PO PUSH ON
SSMH SANITARY SEWER MANHOLE
SR SHORT RADIUS
AH AHEAD
BK BACK
POB POINT OF BEGINNING
POE POINT OF END
1111 Corporate Center Dr Suite 303, Monterey Park
CA 91754
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
N/ASCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
DN
CDR SEP/26
N/A
WD-06-26
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT CHERRY AVE SEWER
IMPROVEMENT PROJECT WASM KV
ABBREVIATIONS, LACSD CONNECTION NOTES
AND PUBLIC AGENCIES
ES EXTRA STRENGTH
PUBLIC AGENCIES & UTILITIES
(562) 570-2525
LONG BEACH, CA 90808
CROWN CASTLE
3205 LAKEWOOD BLVD.
CITY OF LONG BEACH - FIRE DEPARTMENT
1800 EAST WARDLOW ROAD
CITY OF LONG BEACH - TRAFFIC SIGNALS / LIGHTS
(562) 570-2300
LONG BEACH, CA 90806
LONG BEACH PUBLIC UTILITIES DEPARTMENT
2400 E SPRING ST.
(562) 570-3264
LONG BEACH, CA 90807
CITY OF LONG BEACH ENERGY RESOURCE DEPARTMENT (562) 570-2000
MCI VERIZON (800) 289-2427
(800) 654-3110
CANONSBURG, PA
1500 CORPORATE DRIVE
(562) 570-2300
LONG BEACH, CA 90807
1800 EAST WARDLOW ROAD
SPECTRUM - BELLFLOWER (562) 383-9963
JUAN GUARADO
SCE METRO WEST (909) 308-6320
CHINO, CA 91710
1400 S BENSON AVE
SCE TRANS TELECOM (626) 308-6320
ALHAMBRA, CA 91803
501 S MARENGO BLDG E RALPH AGUIRRE
FRONTIER (323) 308-6320
CATHY BROWN
AT&T (888) 290-3111
AT&T DISTRIBUTION
(562) 908-4288
COMPTON, CA 90221
920 S. ALAMEDA ST.
L.A. COUNTY - SANITATION DISTRICT
(626) 458-7822
ALHAMBRA, CA 91803-1331
900 S. FREMONT AVE., 8TH FLOOR
L.A. COUNTY - FLOOD CONTROL DISTRICT
HARRY CONG
LOS ANGELES COUNTY SANITATION DISTRICTS (LACSD) CONNECTION NOTES
1. NOTIFY THE LOS ANGELES COUNTY SANITATION DISTRICTS (LACSD) CONSTRUCTION MANAGEMENT SECTION HEAD AT (562) 908-4288, EXT. 2106 AT LEAST 5 WORKING DAY PRIOR TO START OF WORK ON THE LACSD MANHOLE
(MH) TO ARRANGE FOR INSPECTION.
2. VERIFY EXISTING SEWER INVERTS PRIOR TO CONSTRUCTION.
3. SEND MH SHORING (SEE NOTE 9), NON SHRINK GROUT PER SECTION 201-7.2 OF THE GREEN BOOK AND AMENDMENTS, TRAFFIC PLATING (WHEN APPLICABLE, SEE NOTE 4), CONTROLLED LOW-STRENGTH MATERIAL (CLSM) (TO BE USED AS NON-STRUCTURAL BACKFILL PER SECTION 201-6.1.1 OF THE GREEN BOOK AND AMENDMENTS), NON-SAG POLYMER-MODIFIED MORTAR PER SECTION 502-5.5.4 OF THE GREEN BOOK AND AMENDMENTS, BONDING PRIMER (MUST BE COMPATIBLE WITH THE NON-SAG POLYMER-MODIFIED MORTAR), AND FLOW THRU PLUG TO THE LACSD SEWER DESIGN SECTION FOR APPROVAL PRIOR OF THE START OF
CONSTRUCTION. ALLOW 3 WEEKS FOR REVIEW OF EACH SUBMITTAL.
4. WHENEVER VEHICULAR TRAFFIC IS REQUIRED TO BE RESTORED OVER AN EXCAVATION, STEEL PLATE BRIDGING SHALL BE INSTALLED AND MAINTAINED BY THE CONTRACTOR TO THE SATISFACTION OF THE ENGINEER. FOR EXCAVATION WIDTHS LESS THAN 4'-0", THE STEEL PLATE BRIDGING SHALL BE PER STANDARD DRAWING S-a-231 OR S-a-232 (WHERE APPLICABLE). FOR EXCAVATION WIDTHS GREATER THAN 4'-0", THE STEEL PLATE BRIDGING SHALL BE DESIGNED AND STAMPED BY A CIVIL ENGINEER OR STRUCTURAL ENGINEER CURRENTLY REGISTERED IN THE STATE OF CALIFORNIA AND SHALL BE SUBMITTED TO LACSD FOR ACCEPTANCE PRIOR TO START OF
WORK.
5. WHEN ALLOWED BY THE LACSD INSPECTOR, CORE-DRILL THE MH BASE, INSTALL THE PROPOSED SEWER PIPE, INSERT A FLEXIBLE FLOW-THRU PLUG IN THE MH TO CONTAIN THE FLOW, AND COMPLETE CHANNELIZATION OF THE MH BASE IN THE DRY. THE CONTRACTOR MAY BE REQUIRED TO REMOVE THE MH CONE IN ORDER TO INSTALL THE FLEXIBLE FLOW THRU PLUG. AS OF 2023, THE PEAK FLOW IN THE 30-INCH TRUNK SEWER WAS 15.5 CFS, AND THE LOW FLOW WAS 7.74 CFS DURING THE HOURS OF 06:15 AND 10:15 DURING WET WEATHER. THIS WORK MAY HAVE TO BE PERFORMED DURING OVERNIGHT HOURS WHEN FLOWS ARE LOWER. WHEN USING A FLOW THRU PLUG, THE CONTRACTOR SHALL TAKE BEFORE AND AFTER PICTURES OF THE FLOW THRU PLUG
INSTALLATION INSIDE THE MH TO DOCUMENT THE MH CONDITION.
6. PROTECT EXISTING BRICK OR CONCRETE MH SHAFT DURING CONSTRUCTION. BACKFILL AROUND MANHOLE USING CLSM AS TRENCH BACKFILL PER SECTION 201-6.1.1 OF THE GREEN BOOK AND AMENDMENTS, EXTENDING A MINIMUM OF 2 FEET BEYOND THE OUTSIDE OF THE MH. WHEN APPLICABLE, RECONSTRUCTION OF BRICK MH SHALL BE PER LACSD STANDARD DRAWING S-a-219.
7. PERFORM VIDEO INSPECTION OF THE COMPLETED CONNECTION INSIDE THE MH AND PROVIDE VIDEO TO LACSD INSPECTOR TO CONFIRM SATISFACTORY COMPLETION OF THE WORK. PERFORM VIDEO INSPECTION OF THE COMPLETED CONNECTION INSIDE THE MH AND PROVIDE VIDEO TO LACSD INSPECTOR TO CONFIRM
SATISFACTORY COMPLETION OF THE WORK.
8. NOTE THAT THE MH DETAIL IS A SCHEMATIC AND MAY NOT BE A TRUE REPRESENTATION OF THE EXISTING MH IN
THE FIELD.
9. THE MH SHORING SUBMITTAL SHALL INCLUDE THE FOLLOWING: A) THE ANTICIPATED LOADS ON THE SHORING, INCLUDING SURCHARGE; B) DRAWINGS AND DETAILS, INCLUDING THE MANUFACTURER'S DATA SHEET, INDICATING ONLY THE SHORING BRACES/PLATES TO BE USED; AND C) ENGINEERING CALCULATIONS TO SHOW THE SHORING IS APPROPRIATE FOR THE DEPTH, TRENCH WIDTH, AND ANTICIPATED LOADS. THE DRAWINGS AND CALCULATIONS SHALL BE STAMPED AND SIGNED BY A CIVIL OR STRUCTURAL ENGINEER CURRENTLY
REGISTERED TO PRACTICE IN THE STATE OF CALIFORNIA.
10. PER SECTION 306-7.4.2.5 OF THE GREEN BOOK AND AMENDMENTS, A FLEXIBLE JOINT SHALL BE INSTALLED IN THE PIPELINE WITHIN 18 INCHES OF THE OUTSIDE WALL OF THE LACSD MANHOLE, AND AN ADDITIONAL FLEXIBLE
JOINT SHALL BE INSTALLED 2 FEET FROM THE FIRST JOINT.
S A
I K
- C H O O N P O
H
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
PLAN AND PROFILE - GARDENIA AVE STA 30+02 TO STA 32+98
& E ANAHEIM ST STA 10+02 TO STA 11+00
31+00
EL
EV
AT
IO
N (F
EE
T)
32+00 33+00 9+00 10+00 11+00
EL
EV
AT
IO
N (F
EE
T)
EL
EV
AT
IO
N (F
EE
T)
30+00
GARDENIA AVE
G A
R D
E N
IA
A
V E
E ANAHEIM ST
EL
EV
AT
IO
N (F
EE
T)
K12K13
M A
TC
H
LI
N
E S
TA
. 1
1+
S E
E S
H E
E T
C -0
10 10
35 35
15 15
NOTES TO CONTRACTOR
CONSTRUCTION NOTES
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD.
DWG WDS-511
REMOVE EXISTING 15-INCH SEWER MAIN AND CONSTRUCT 18-INCH VITRIFIED CLAY
PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
4 REMOVE EXISTING 10-INCH SEWER MAIN AND CONSTRUCT 12-INCH VITRIFIED CLAY
PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
10 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND RELINE MAINTENANCE HOLE
MATCHLINE STA. 11+00
ANAHEIM ST - SHEET C-002
EX. LACSD MH (03 0317) AT STA. 30+00.00 =
LACSD STA. 104+74.00 PER 03-P-0062
CONNECTION DETAIL
SECTION VIEW
4 6
EL
EV
AT
IO
N (F
EE
T)
1. FOR CONSTRUCTION AT OR RELATED TO LACSD'S
FACILITY, CONTRACTOR SHALL ADHERE TO LACSD
CONNECTION NOTES ON SHEET 4
DETAIL NOTE
EL
EV
AT
IO
N (F
EE
T)
12 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND CONNECT TO EXISTING
LACSD MH #03 0317 PER CONNECTION DETAIL A ON DRAWING C-001
1. INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF EXISTING SEWER LATERALS
SHALL COMPLY WITH SPECIFICATIONS AND INSPECTION BY LBUD.
2. SEWER LATERALS SHOWN ON THE PLANS ARE APPROXIMATE IN LOCATION BASED ON AVAILABLE INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING LATERALS PRIOR TO EXCAVATION
AND LATERAL REINSTATEMENT OR REPLACEMENT.
3. CONTRACTOR SHALL CONDUCT A CCTV INSPECTION AND REVIEW PRIOR TO THE START OF WORK
TO DETERMINE THE EXACT LOCATIONS OF SEWER LATERALS. CONTRACTOR SHALL POTHOLE OR
EXCAVATE AS NEEDED TO DETERMINE ELEVATIONS AND VERIFY THAT RECONNECTIONS WILL MEET
LBUD SPECIFICATIONS.
4. ALL UTILITIES SHOWN ON THE PLANS ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE
ENGINEER DURING DESIGN. CONTRACTOR TO POTHOLE TO VERIFY LOCATION (HORIZONTAL AND
VERTICAL) PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IMMEDIATELY OF ANY CONFLICT.
5. PRIOR TO MAKING SEWER MAIN CONNECTIONS AND BEFORE BEGINNING
OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THE LOCATION AND
ELEVATION OF EXISTING SEWER MAINS AND ADJACENT UTILITIES.
6. CONTRACTOR TO MATCH EXISTING INVERT ELEVATIONS WHERE NOTED.
7. CONTRACTOR TO VERIFY INVERT ELEVATION OF EXISTING LACSD AT
MH#03 0317 AND PROVIDE INFORMATION IN AS-BUILT.
8. IF 1-SACK CEMENT-SAND SLURRY IS APPROVED AND UTILIZED BY
CONTRACTOR FOR TRENCH BACKFILLING, CONTRACTOR SHALL TAKE
ALL CAUTION WHEN BACKFILLING TO PREVENT MISALIGNMENT OR
FLOATING OF THE INSTALLED PIPELINE. CONTRACTOR SHALL BACKFILL
IN APPROPRIATE LIFT DEPTHS AND MEET REQUIREMENTS PER
SPECIFICATIONS SECTION 31 23 00, 31 23 33, AND OTHER CONTRACT
DOCUMENTS.
PLAN AND PROFILE - E ANAHEIM ST STA 11+00 TO STA 13+08
& CHERRY AVE STA 49+82 TO STA 52+00
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
12+00
EL
EV
AT
IO
N (F
EE
T)
13+00 14+00 50+00 51+00 52+00
EL
EV
AT
IO
N (F
EE
T)
EL
EV
AT
IO
N (F
EE
T)
11+00
M A
TC
H
LI
N
E S
TA
. 1
1+
E A
N A
H E
IM
S
T
- S
H E
E T
C -0
MATCHLINE STA. 52+00
CHERRY AVE - SHEET C-003
49+00
EL
EV
AT
IO
N (F
EE
T)
E A
N A
H E
IM
S
T
E ANAHEIM ST
CHERRY AVE
L12K12
M A
TC
H
LI
N
E S
TA
. 5
2+
S E
E S
H E
E T
C -0
S E
E S
H E
E T
C -0
M
A
TC
H
LI
N E
S
TA
. 1 1+
1010 10 10
CONSTRUCTION NOTES
2 CONSTRUCT 12-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH
COMPRESSION JOINTS
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
9 CONSTRUCT 48-INCH DIAMETER MAINTENANCE HOLE PER LBUD STD. DWG WDS-502
REMOVE EXISTING 15-INCH SEWER MAIN AND CONSTRUCT 18-INCH VITRIFIED CLAY
PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
10 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND RELINE MAINTENANCE HOLE
10 17 9 9
NOTES TO CONTRACTOR
1. INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF EXISTING SEWER LATERALS SHALL
COMPLY WITH SPECIFICATIONS AND WILL REQUIRE A SEWER PERMIT AND INSPECTION BY LBUD.
2. SEWER LATERALS SHOWN ON THE PLANS ARE APPROXIMATE IN LOCATION BASED ON AVAILABLE
INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING LATERALS PRIOR TO EXCAVATION AND
LATERAL REINSTATEMENT OR REPLACEMENT.
3. CONTRACTOR SHALL CONDUCT A CCTV INSPECTION AND REVIEW PRIOR TO THE START OF WORK TO DETERMINE THE EXACT LOCATIONS OF SEWER LATERALS. CONTRACTOR SHALL POTHOLE OR EXCAVATE
AS NEEDED TO DETERMINE ELEVATIONS AND VERIFY THAT RECONNECTIONS WILL MEET LBUD
SPECIFICATIONS.
4. ALL UTILITIES SHOWN ON THE PLANS ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE
ENGINEER DURING DESIGN. CONTRACTOR TO POTHOLE TO VERIFY LOCATION (HORIZONTAL AND
VERTICAL) PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IMMEDIATELY OF ANY CONFLICT.
5. PRIOR TO MAKING SEWER MAIN CONNECTIONS AND BEFORE BEGINNING OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF EXISTING SEWER MAINS AND ADJACENT UTILITIES.
6. CONTRACTOR TO MATCH EXISTING INVERT ELEVATIONS WHERE NOTED.
7. IF 1-SACK CEMENT-SAND SLURRY IS APPROVED AND UTILIZED BY CONTRACTOR FOR TRENCH BACKFILLING, CONTRACTOR SHALL TAKE ALL CAUTION WHEN BACKFILLING TO PREVENT MISALIGNMENT OR FLOATING OF THE INSTALLED PIPELINE. CONTRACTOR SHALL BACKFILL IN APPROPRIATE LIFT DEPTHS AND MEET REQUIREMENTS PER SPECIFICATIONS SECTION 31 23 00, 31 23 33, AND OTHER CONTRACT DOCUMENTS.
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD.
DWG WDS-511
17 CONSTRUCT 60-INCH DIAMETER DROP MAINTENANCE HOLE PER LBUD STD. DWG
WDS-503
14 ABANDON EXISTING SEWER PIPELINE
C H
E R
R Y
A V
E
8 REPLACE EXISTING HOUSE CONNECTION WITH NEW LATERAL PER LBUD STD DWG WDS-506
MODIFIED ON SHEET C-6, AND REPLACE LATERAL UP TO AND MAKE RECONNECTION AT THE
PROPERTY LINE
PLAN AND PROFILE
CHERRY AVE STA 52+00 TO STA 60+00
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
53+00
EL
EV
AT
IO
N (F
EE
T)
54+00 55+00 56+00
EL
EV
AT
IO
N (F
EE
T)
52+00
M A
TC
H
LI
N
E S
TA
. 6
0+
C H
E R
R Y
S
H E
E T
C -0
M A
TC
H
LI
N
E S
TA
. 5
2+
C H
E R
R Y
A V
E
S H
E E
T C
-0
57+00 58+00 59+00 60+00
CHERRY AVE
S E
E S
H E
E T
C -0
M
A
TC
H
LI
N E
S
TA
. 5 2+
M A
TC
H
LI
N
E S
TA
. 6
0+
S E
E S
H E
E T
C -0
CONSTRUCTION NOTES
CONSTRUCT 10-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH
COMPRESSION JOINTS
CONSTRUCT 12-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH
COMPRESSION JOINTS
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
REPLACE EXISTING HOUSE CONNECTION WITH NEW LATERAL PER LBUD STD DWG WDS-506
MODIFIED ON SHEET C-6, AND REPLACE LATERAL UP TO AND MAKE RECONNECTION AT THE
PROPERTY LINE
9 CONSTRUCT 48-INCH DIAMETER MAINTENANCE HOLE PER LBUD STD. DWG WDS-502
3 REMOVE EXISTING 8-INCH SEWER MAIN AND CONSTRUCT 10-INCH VITRIFIED CLAY
PIPE (VCP), EXTRA STRENGTH WITH COMPRESSION JOINTS
62 61 63
6NOTES TO CONTRACTOR
1. INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF EXISTING SEWER LATERALS SHALL
COMPLY WITH SPECIFICATIONS AND WILL REQUIRE A SEWER PERMIT AND INSPECTION BY LBUD.
2. SEWER LATERALS SHOWN ON THE PLANS ARE APPROXIMATE IN LOCATION BASED ON AVAILABLE
INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING LATERALS PRIOR TO EXCAVATION AND
LATERAL REINSTATEMENT OR REPLACEMENT.
3. CONTRACTOR SHALL CONDUCT A CCTV INSPECTION AND REVIEW PRIOR TO THE START OF WORK TO DETERMINE THE EXACT LOCATIONS OF SEWER LATERALS. CONTRACTOR SHALL POTHOLE OR EXCAVATE
AS NEEDED TO DETERMINE ELEVATIONS AND VERIFY THAT RECONNECTIONS WILL MEET LBUD
SPECIFICATIONS.
4. ALL UTILITIES SHOWN ON THE PLANS ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE
ENGINEER DURING DESIGN. CONTRACTOR TO POTHOLE TO VERIFY LOCATION (HORIZONTAL AND
VERTICAL) PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IMMEDIATELY OF ANY CONFLICT.
5. PRIOR TO MAKING SEWER MAIN CONNECTIONS AND BEFORE BEGINNING OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF EXISTING SEWER MAINS AND ADJACENT UTILITIES.
6. CONTRACTOR TO MATCH EXISTING INVERT ELEVATIONS WHERE NOTED.
8 8 8
7 7 7 7
7 7
8 7
88 87 8
7 8 8 7 7 7 7
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD.
DWG WDS-511
14 13
13 ABANDON EXISTING MAINTENANCE HOLE PER DETAIL 2 ON SHEET 10
14 ABANDON EXISTING SEWER PIPELINE
16 REMOVE EXISTING SEWER PIPELINE
CHERRY AVE STA 60+00 TO STA 68+00
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
61+00 62+00 63+00 64+0060+00 65+00 66+00 67+00 68+00
M A
TC
H
LI
N
E S
TA
. 6
8+
C H
E R
R Y
A V
E
S H
E E
T C
-0
M A
TC
H
LI
N
E S
TA
. 6
0+
C H
E R
R Y
A V
E
S H
E E
T C
-0
10TH STREET
10TH STREET
CHERRY AVE
L11K12
S E
E S
H E
E T
C -0
M
A
TC
H
LI
N E
S
TA
. 6 0+
M A
TC
H
LI
N
E S
TA
. 6
8+
S E
E S
H E
E T
C -0
EL
EV
AT
IO
N (F
EE
T)
EL
EV
AT
IO
N (F
EE
T)
20 20
CONSTRUCTION NOTES
1 CONSTRUCT 10-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH
COMPRESSION JOINTS
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
REPLACE EXISTING HOUSE CONNECTION WITH NEW LATERAL PER LBUD STD DWG WDS-506
MODIFIED ON SHEET C-6, AND REPLACE LATERAL UP TO AND MAKE RECONNECTION AT THE
PROPERTY LINE
9 CONSTRUCT 48-INCH DIAMETER MAINTENANCE HOLE PER LBUD STD. DWG WDS-502
61 61 61
77878
NOTES TO CONTRACTOR
1. INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF EXISTING SEWER LATERALS SHALL
COMPLY WITH SPECIFICATIONS AND WILL REQUIRE A SEWER PERMIT AND INSPECTION BY LBUD.
2. SEWER LATERALS SHOWN ON THE PLANS ARE APPROXIMATE IN LOCATION BASED ON AVAILABLE
INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING LATERALS PRIOR TO EXCAVATION AND
LATERAL REINSTATEMENT OR REPLACEMENT.
3. CONTRACTOR SHALL CONDUCT A CCTV INSPECTION AND REVIEW PRIOR TO THE START OF WORK TO DETERMINE THE EXACT LOCATIONS OF SEWER LATERALS. CONTRACTOR SHALL POTHOLE OR EXCAVATE
AS NEEDED TO DETERMINE ELEVATIONS AND VERIFY THAT RECONNECTIONS WILL MEET LBUD
SPECIFICATIONS.
4. ALL UTILITIES SHOWN ON THE PLANS ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE
ENGINEER DURING DESIGN. CONTRACTOR TO POTHOLE TO VERIFY LOCATION (HORIZONTAL AND
VERTICAL) PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IMMEDIATELY OF ANY CONFLICT.
5. PRIOR TO MAKING SEWER MAIN CONNECTIONS AND BEFORE BEGINNING OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF EXISTING SEWER MAINS AND ADJACENT UTILITIES.
6. CONTRACTOR TO MATCH EXISTING INVERT ELEVATIONS WHERE NOTED.
8 8 8 8
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD.
DWG WDS-511
13 ABANDON EXISTING MAINTENANCE HOLE PER DETAIL 2 ON SHEET 10
14 ABANDON EXISTING SEWER PIPELINE
15 REMOVE EXISTING MAINTENANCE HOLE
18 CONSTRUCT COMPRESSIBLE BLANKET FOR UTILITY CROSSING PER DETAIL 4 ON
SHEET 10
CHERRY AVE STA 68+00 TO STA 74+55
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
69+00 70+00 71+00 72+0068+00 73+00 74+00 75+00
M A
TC
H
LI
N
E S
TA
. 6
8+
C H
E R
R Y
A V
E
S H
E E
T C
-0
8TH STREET
8TH STREET
CHERRY AVE
C H
ER
R
Y
AV
E
S
E E
S H
E E
T C
-0
M A
TC
H
LI
N
E S
TA
. 6
8+
EL
EV
AT
IO
N
(F
EE
T)
EL
EV
AT
IO
N (F
EE
T)
50 50
CONSTRUCTION NOTES
1 CONSTRUCT 10-INCH VITRIFIED CLAY PIPE (VCP), EXTRA STRENGTH WITH
COMPRESSION JOINTS
EXCAVATE, BACKFILL AND COMPACT TRENCH PER LBUD STD. DWG WDS-406
REPLACE EXISTING HOUSE CONNECTION WITH NEW LATERAL PER LBUD STD DWG WDS-506
MODIFIED ON SHEET C-6, AND REPLACE LATERAL UP TO AND MAKE RECONNECTION AT THE
PROPERTY LINE
9 CONSTRUCT 48-INCH DIAMETER MAINTENANCE HOLE PER LBUD STD. DWG WDS-502
10 PROTECT IN PLACE EXISTING MAINTENANCE HOLE AND RELINE MAINTENANCE HOLE
6 6
9 9
9 10
61 61
1 1
88 8
NOTES TO CONTRACTOR
1. INSTALLATION OF SEWER SERVICE CONNECTIONS AND CAPPING OF EXISTING SEWER LATERALS SHALL
COMPLY WITH SPECIFICATIONS AND WILL REQUIRE A SEWER PERMIT AND INSPECTION BY LBUD.
2. SEWER LATERALS SHOWN ON THE PLANS ARE APPROXIMATE IN LOCATION BASED ON AVAILABLE
INFORMATION. CONTRACTOR SHALL FIELD LOCATE ALL EXISTING LATERALS PRIOR TO EXCAVATION AND
LATERAL REINSTATEMENT OR REPLACEMENT.
3. CONTRACTOR SHALL CONDUCT A CCTV INSPECTION AND REVIEW PRIOR TO THE START OF WORK TO DETERMINE THE EXACT LOCATIONS OF SEWER LATERALS. CONTRACTOR SHALL POTHOLE OR EXCAVATE AS NEEDED TO DETERMINE ELEVATIONS AND VERIFY THAT RECONNECTIONS WILL MEET LBUD SPECIFICATIONS.
4. ALL UTILITIES SHOWN ON THE PLANS ARE BASED ON THE BEST INFORMATION AVAILABLE TO THE ENGINEER DURING DESIGN. CONTRACTOR TO POTHOLE TO VERIFY LOCATION (HORIZONTAL AND VERTICAL) PRIOR TO
CONSTRUCTION AND INFORM THE ENGINEER IMMEDIATELY OF ANY CONFLICT.
5. PRIOR TO MAKING SEWER MAIN CONNECTIONS AND BEFORE BEGINNING OF CONSTRUCTION, CONTRACTOR SHALL VERIFY THE LOCATION AND ELEVATION OF EXISTING SEWER MAINS AND ADJACENT UTILITIES.
6. CONTRACTOR TO MATCH EXISTING INVERT ELEVATIONS WHERE NOTED.
7. CONTRACTOR SHALL CONSTRUCT CONCRETE BLANKET PER LBUD STD. DWG WDS-129
CONNECT EXISTING LATERAL TO NEW PROPOSED SEWER MAIN PER LBUD STD.
DWG WDS-511
13 14
13 ABANDON EXISTING MAINTENANCE HOLE PER DETAIL 2 ON SHEET 10
14 ABANDON EXISTING SEWER PIPELINE
CONSTRUCT 10" HDPE SDR-21 (FUSION WELDED JOINTS) PIPE WRAPPED WITH
POLYETHYLENE LINER PPL-24 OR APPROVED EQUAL. POLYETHYLENE LINER SHALL
BE HEAT WELDED
6" 6"
COMPRESSIBLE BLANKET
NOTES FOR COMPRESSIBLE BLANKET:
1. COMPRESSIBLE BLANKET IS REQUIRED WHEN THE CLEARANCE BETWEEN THE BOTTOM OF THE NEW PIPE AND THE
TOP OF THE CROSSING CONDUIT (BOX OR ARCH) IS LESS THAN 18".
2. THE BLANKET SHALL EXTEND LONGITUDINALLY FOR THE FULL CROSSING CONDUIT TRENCH WIDTH.
STREET CENTERLINE
3 TO 6 INCHES
6"
MIN.
18"
SEE
NOTES 1 & 2
CONCRETE COLLAR -
SEE NOTE 3
CAST IRON CLEANOUT
FRAME AND COVER,
SEE SHEET 4 OF WDS-506
6" PVC PIPE
6" PVC BEND MIN S=2%*
6"
SEWER MAIN
3/4" CRUSHED
ROCK BEDDING
12"
SEWER PIPE IN
PRIVATE PROPERTY
CUSTOMER CONNECT HERE
6" PVC PIPE
ELEVATION A-A
STREET CENTERLINE
6" VITRIFIED CLAY
PIPE 1/8 BEND
PIPE SIZE x 6" VCP WYE
SEWER MAIN
A
A
CLEANOUT COVER
SEE NOTES 1 & 2
PROPERTY LINE
6" X 6" PVC WYE
6" CLEANOUT PER DETAIL B
PROPERTY LINE
FINISH GRADE
BELL & SPIGOT
JOINT (TYP)
PLAN
NOTES:
1. IF THE CLEANOUT IS WITHIN OR IS IN CONFLICT WITH THE SIDEWALK AREA OR WALKING ZONE, IT SHALL BE
RELOCATED TO AN AREA WHEREAS THE BOX WILL NOT POSE A TRIPPING HAZARD.
2. ACTUAL LOCATION OF CLEANOUT TO BE VERIFIED WITH LBUD INSPECTION.
3. CONCRETE COLLAR SHALL BE 20" IN DIAMETER AND SHALL BE CLASS A2 CONCRETE (600-C-2500).
4. FOR LATERALS > 6", UPSIZE CLEANOUT TO MATCH LATERAL DIAMETER, SUBMIT SHOP DRAWING FOR CLEANOUT
FRAME AND COLLAR.
5. PVC AND ABS JOINTS SHALL BE GLUED OR JOINED TO BE WATERTIGHT.
6. USE OF ABS PIPE IN LIEU OF PVC SUBJECT TO LBUD APPROVAL.
7. REFER TO LBUD STD WDS-506 FOR STANDARD DETAIL NOT OUTLINED IN WDS-506 MODIFIED DETAIL
SOLVENT WELD x F.I.P.T.
PVC COUPLING
6" PVC PIPE
PVC STOPPER M.I.P.T.
PLUG WITH MALE
SQUARE NUT
DETAIL B
* OR AS APPROVED BY LBUD IN FIELD
3'
MIN.
6" PVC PIPE
6" VCP PIPE
6" TRANSITION COUPLING
6" PVC PIPE
6" TRANSITION COUPLING
MISCELLANEOUS DETAILS
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
MAINTENANCE HOLE ABANDONMENT
2CONNECTION DETAIL
1 ABANDONMENT DETAIL
COMPRESSIBLE BLANKET
4LBUD STD DWG WDS-129 MODIFIED
EXISTING SEWER PIPE MAINTENANCE HOLE
SEWER CLEANOUT - LATERAL
LBUD STD DWG WDS-506 MODIFIED
CONNECTION DETAILS
CHERRY AVE SEWER
IMPROVEMENT PROJECT
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
1"= 40'SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE SEP/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGÁN
GENERAL MANAGER
LONG BEACH PUBLIC
UTILITIES DEPARTMENT
DN
CDR SEP/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
WD-06-26
S A
I K
- C H O O N P O
H
DRAWING / FILE NUMBER:
SC-0512
FAMIS PROJECT:
MUNIS PROJECT:
6517050001
WASM KV
MAINTENANCE HOLE CONNECTION DETAIL
GARDENIA AVE: STA 33+00.68
MAINTENANCE HOLE CONNECTION DETAIL
GARDENIA AVE: STA 30+28.51
MAINTENANCE HOLE CONNECTION DETAIL
ANAHEIM ST: STA 10+00.00
MAINTENANCE HOLE CONNECTION DETAIL
ANAHEIM ST: STA 13+38.02
MAINTENANCE HOLE CONNECTION DETAIL
CHERRY AVE: STA 61+54.51
MAINTENANCE HOLE CONNECTION DETAIL
CHERRY AVE: STA 74+56.86
MAINTENANCE HOLE CONNECTION DETAIL
ANAHEIM ST: STA 13+08.53
| SHEET_01_00G-_001-G2 |
| Sheets and Views |
| G2 |
| SHEET_02_00G-_002-G2 |
| Sheets and Views |
| G2 |
| SHEET_03_G03-G3 |
| Sheets and Views |
| G3 |
| SHEET_04_G04-G3 |
| Sheets and Views |
| G3 |
| SHEET_05_C01-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_06_C02-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_07_C03-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_08_C04-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_09_C05-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_10_C06-C-1 |
| Sheets and Views |
| C-1 |
| SHEET_11_C07-C-1 |
| Sheets and Views |
| C-1 |
File details come from the government source that posted it. Updated .