2-SAISD Warehouse Repair - 100% CD Drawings.pdf
PDF 19 MB Posted
- Attached to
- 26-027 (BS) Summit Warehouse Repairs
- Solicitation number
- 26-027 (BS) Summit Warehouse Repairs
- Issued by
- Bexar County, Savannah CDP, Texas
About this file
This document is a 100% Construction Document (CD) set of architectural drawings and specifications prepared by LPA, Inc. for the San Antonio Independent School District (SAISD) to repair the Summit Warehouse facility located at 1270 W. Summit Avenue in San Antonio, Texas. The scope of work includes architectural, structural, electrical, technology, and security design services necessary to restore functionality to damaged portions of the warehouse, specifically limited to building envelope restoration, relocation of the IDF (Intermediate Distribution Frame) cabinet, restoration of the IDF/office room (Room 230), and restoration of warehouse bay 1 (Room 233). The design documents were submitted at 50% completion on March 20, 2026, 75% completion on April 15, 2026, and 100% completion on May 13, 2026. The project is being directed by SAISD with Kamal Elhabiri as the primary contact, and the design team includes LPA, Inc. as the architect and KCA as the structural engineer.
The construction documents comply with the 2024 International Building Code, 2024 International Existing Building Code, 2021 International Energy Conservation Code, 2024 National Electric Code, 2024 International Fire Code, and 2012 Texas Accessibility Standards. The drawings establish detailed requirements for fire and life safety systems, including automatic sprinkler systems, fire extinguishers, exit signage, fire lanes, and accessibility compliance throughout the restoration work. The contractor is responsible for all construction means, methods, site safety, and coordination with local authorities for lane closures and traffic control. All dimensions, materials, and specifications must conform to applicable codes and ordinances, with the structural engineer providing observation during construction and the contractor required to submit a surveyor's certificate prior to final project completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-Summit Warehouse Repairs - 100% CD Project Manual.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
PROJECT NUMBER
Submittal Date
50% CD 03/20/2026
75% CD 04/15/2026
100% CD 05/13/2026
33160
SAISD WAREHOUSE REPAIR
1270 W SUMMIT AVE.
SAN ANTONIO, TX 78201
G0.00
COVER SHEET
100% CD
03/23/2026
100% CD
05/13/2026
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C T
05/13/2026
DIRECTOR OF FACILITY
NAME: SAN ANTONIO ISD
CLIENT INFORMATION
CITY,STATE, ZIP: SAN ANTONIO, TX 78201
ADDRESS: 1270 W. SUMMIT
CONTACT: KAMAL ELHABIRI E-MAIL: KELHABR@saisd.net
NAME: LPA, INC.
ARCHITECT
CITY,STATE, ZIP: SAN ANTONIO, TX 78204
ADDRESS: 1811 SOUTH ALAMO STREET, SUITE 100
CONTACT: SARA FLOWERS E-MAIL: SFLOWERS@lpadesignstudios.com
NAME: LPA, INC.
CITY,STATE, ZIP: DALLAS, TX 75202
ADDRESS: 1801 NORTH LAMAR STREET #150
CONTACT: JOHN HOENIG E-MAIL: JHOENIG@lpadesignstudios.com
NAME: KCA
CITY,STATE, ZIP: SAN ANTONIO TX 78254
ADDRESS: 21718 CHAUCER HILL
CONTACT: LON CULBERTSON E-MAIL: LCULBERTSON@lpadesignstudios.com
STRUCTURAL ENGINEER
ELECTRICAL ENGINEER
N
PROJECT NORTH
RESTORATION SITE:
SAISD WAREHOUSE
ADDRESS:
3031 IH 10 WEST
SAN ANTONIO,TX 78201
N
TRUE NORTH
THE SCOPE OF WORK INCLUDES PROVIDING ARCHITECTURAL, STRUCTURAL,
ELECTRICAL, TECHNOLOGY, AND SECURITY DESIGN SERVICES NECESSARY TO
RESTORE FUNCTIONALITY TO THE DAMAGED PORTIONS OF THE SAISD
WAREHOUSE. WORK IS SPECIFICALLY LIMITED TO BUILDING ENVELOP
RESTORATION, RELOCATION OF IDF CABINET, THE IDF/OFFICE ROOM (230) AND
WAREHOUSE BAY 1 (233) RESTORATION .
THE LIMIT OF WORK IS THE RESTORATION OF FUNCTIONALITY TO THE
DAMAGED PORTIONS OF THE SAISD WAREHOUSE LIMITED AT THE IDF/OFFICE
ROOM (230) AND W AREHOUSE BAY 1 (233). SERVICES SHALL INCLUDE
ARCHITECTURAL, STRUCTURAL, ELECTRICAL, TECHNOLOGY.
1. IMP-1 BUILDING ENVELOP DESIGN
CAB CABINET
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CI CAST IRON
CIP CAST IN PLACE
CIV ENG CIVIL ENGINEER
CG CORNER GUARD
CJ CONTROL JOINT
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
CNTR COUNTER
CO CASED OPENING
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSUNK
DA DISABLED ACCESS
DBL DOUBLE
DEPT. DEPARTMENT
DESC DESCRIPTION
DF DRINKING FOUNTAIN
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DO DOOR OPENING
DR DOOR
DWR DRAW ER
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAW ING
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXPO EXPOSED
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FLASH FLASHING
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOV FACE OF VENEER (BRICK OR
PRECAST)
FOW FACE OF WALL
FR FIRE RETARDANT
FPRF FIREPROOF
FS FINISH SURFACE
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GI GALVANIZED IRON
GL GLASS
GND GROUND
GR GRADE
GYP GYPSUM
HB HOSE BIB
HC HOLLOW CORE
HDWD HARDWOOD
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HGT/HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE
LAND ARCH LANDSCAPE ARCHITECT
LAV LAVATORY
LKR LOCKER
LT LIGHT
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MUL MULLION
N NORTH
NIC NOT IN CONTRACT
NO/# NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OA OUTSIDE AIR
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
OSA OUTSIDE AIR
PA PLANTING AREA
PRCST PRECAST
PH PANIC HARDWARE
PL PLATE
P LAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
POT PATH OF TRAVEL
PR PAIR
PT PAINT
PTD PAPER TOWEL
DISPENSER
PTD/R COMBINATION PAPER
TOWEL DISPENSER
& RECEPTACLE
PTN PARTITION
PTR PAPER TOWEL
RECEPTACLE
QT QUARRY TILE
R RISER
RAD RADIUS
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
RGTR REGISTER
REINF REINFORCED
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RWD REDWOOD
RWL RAIN WATER LEADER
S SOUTH
SC SOLID CORE
SCD SEAT COVER
DISPENSER
SCHED SCHEDULE
SD SOAP DISPENSER
SECT SECTION
SF SQUARE FEET
SH SHELF
SHR SHOWER
SHT SHEET
SIM SIMILAR
SND SANITARY NAPKIN
DISPENSER
SNR SANITARY NAPKIN
RECEPTACLE
SPEC SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
S SK SERVICE SINK
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T TREAD
TB TOWEL BAR
TC TOP OF CURB
TEL TELEPHONE
TER TERRAZZO
T&G TONGUE & GROOVE
THK THICK
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOW TOP OF WALL
TOP TOP OF PARAPET
TPD TOILET PAPER
DISPENSER
TS TOP OF SLOPE
TV TELEVISION
TYP TYPICAL
UNF UNFINISHED
UNO UNLESS NOTED
OTHERWISE
UR URINAL
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VEST VESTIBULE
W WEST
W/ WITH
WC WATER CLOSET
WD WOOD
W/O WITHOUT
WP WATERPROOF
WR WATER RESISTANT
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
& AND
∠ ANGLE
@ AT
℄ CENTERLINE
∅ DIAMETER OR ROUND
# POUND OR NUMBER
(E) EXISTING
(P) PAINT
(R) REMOVE
+/- DIM TOLERANCE
AC ASPHALTIC CONCRETE
ACC ACCESSIBLE
ACOUS ACOUSTICAL
ACM ALUM COMPOSITE MATERIAL
ACT ACOUS CLG TILE
AD AREA DRAIN
AED AUTO EXT DEFIBRILLATOR
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGGR AGGREGATE
AHJ AUTHORITY HAVING
JURISDICTION
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASF ASSIGNABLE SF
ASPH ASPHALT
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLK'G BLOCKING
BM BEAM
BOC BACK OF CURB
BOT BOTTOM
BO BOTTOM OF
BOC BACK OF CURB
BOW BOTTOM OF WALL
BS BOTTOM OF SLOPE
COLUMN LINES
SURFACE DRAINAGE
ARROW INDICATES
DIRECTION OF FLOW
N
PROJECT NORTH
BUILDING SECTION
SECTION ID
SHEET NUMBER
WALL SECTION
SECTION ID
SHEET NUMBER
DETAIL CALLOUTS
DETAIL ID
SHEET NUMBER
DETAIL SECTION
DETAIL ID
SHEET NUMBER
DETAIL REFERENCE
DETAIL ID
SHEET NUMBER
INTERIOR ELEVATIONS
DETAIL ID
SHEET NUMBER
A
C
SIM
D BA101
DOOR DESIGNATION
ROOM DESIGNATION
ROOM NUMBER
ROOM AREA
1REVISION CLOUD &
TAG (OPTIONAL)
SA2U
1t
SHADED PORTION POINTS
TO SIDE REFERENCED
DATUM POINT
KEYNOTE
WALL TYPE
OPENING DESIGNATION
TYP.
MATCH LINE
SEE SHEET A101
LEVEL LINE, CONTROL POINT
EL: 12'-8" = ELEVATION/SECTION
STAIR DIRECTION
DN
UP
CENTER LINES, LEVEL LINES
HIDDEN CONSTRUCTION FEATURE
BREAK LINE
FINISH TAG XX-##
EQUIPMENT TAG 1i
N
TRUE NORTH
NORTH ARROW
EXTERIOR ASSEMBLY
REFER TO A8.11 R1
Room
A101
TYP
A101
TYP
A101
SIM
A101
SIM
A101
SIM
NOTICE TO PERSONS PERFORMING WORK ON JOB SITE, INCLUDING CONTRACTORS,
SUBCONTRACTORS, MATERIAL SUPPLIERS & ANY AGENTS OR EMPLOYEES THEREOF
THESE PLANS & SPECIFICATIONS DO NOT PROVIDE ANY DIRECTION OR
INSTRUCTIONS TO CONTRACTORS, SUBCONTRACTORS, MATERIAL SUPPLIERS OR
THEIR EMPLOYEES OR AGENTS RELATED TO CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES OR PROCEDURES, SAFETY PRECAUTIONS, MANNERS OR
METHODS OF EGRESS OR INGRESS, INCLUDING BUT NOT LIMITED TO JOB SITE
SAFETY, THE PHYSICAL CONDITION OF THE JOB SITE, THE MANNER OR METHOD IN
WHICH THE AREA WHERE WORK IS PERFORMED IS ACCESSED BY WORKERS, &
SAFETY PROGRAMS OR SAFETY PROTOCOLS OF ANY KIND IN CONNECTION WITH
THE WORK. ALL OF THE FOREGOING ARE SOLELY & EXCLUSIVELY THE
RESPONSIBILITY OF THE CONTRACTOR, SUBCONTRACTOR, MATERIAL SUPPLIERS,
OR ANY AGENTS OR EMPLOYEES THEREOF.
THE ARCHITECT EXPRESSLY DISCLAIMS ANY CONTROL OVER & RESPONSIBILITY FOR
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES,
SAFETY PRECAUTIONS, MANNERS OR METHODS OF EGRESS OR INGRESS,
INCLUDING BUT NOT LIMITED TO JOB SITE SAFETY, THE PHYSICAL CONDITION OF
THE JOB SITE, THE MANNER OR METHOD IN WHICH THE AREA WHERE WORK IS
PERFORMED IS ACCESSED BY WORKERS, & SAFETY PROGRAMS OR SAFETY
PROTOCOLS OF ANY KIND IN CONNECTION WITH THE WORK.
THE ARCHITECT HAS NOT CONDUCTED AN EVALUATION OR ANALYSIS OF SAFETY
PROCEDURES OR APPLICABLE LAW REGARDING OR RELATING TO ACCESSING THE
JOB SITE OR AREAS OF THE WORK DURING THE COURSE OF CONSTRUCTION.
THE ARCHITECT, THE ARCHITECT’S DESIGNS, & ANY OTHER WORK PERFORMED BY
THE ARCHITECT DO NOT ADDRESS, ANALYZE OR PROVIDE ANY DIRECTION OR
ADVICE TO ANY PERSON OR ENTITY ON WHETHER OR NOT THE USE OF EXG
LADDERS, DOORS, RAILINGS, INGRESS & INGRESS ROUTES OR THE LIKE ARE IN
COMPLIANCE OR NON-COMPLIANCE WITH OSHA, CAL-OSHA(CALIFORNIA ONLY), OR
ANY OTHER APPLICABLE STATUTE, REGULATION, OR STANDARD RELATED TO JOB
SITE SAFETY DURING THE COURSE OF CONSTRUCTION OF THE IMPROVEMENTS.
1. PLANS FOR THE FIRE SPRINKLER SYSTEMS MUST BE APPROVED BY THE
AUTHORITY HAVING JURISDICTION (AHJ) PRIOR TO INSTALLATION. SUBMIT
PLANS IN A MANNER WHICH WILL NOT IMPEDE THE PROGRESS OF
CONSTRUCTION.
2. FIRE SPRINKLER SYSTEMS & INSTALLATION SHALL CONFORM W/ THE
APPLICABLE STANDARDS AND CODES.
3. FIRE SPRINKLER SYSTEMS TO BE TIED INTO THE ALARM SYSTEM PER THE
APPLICABLE CODES.
4. AUTOMATIC SPRINKLER SYSTEM(S) SHALL BE SUPERVISED BY AN
APPROVED CENTRAL OR REMOTE STATION SERVICE, AND/OR SHALL BE
PROVIDED W/ A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL.
5. FIRE SPRINKLER SYSTEM(S) & ALL CONTROL VALVES SHALL BE
SUPERVISED BY A U.L. LISTED CENTRAL ALARM STATION OR PER THE
APPLICABLE CODES.
6. FIRE HYDRANT & FIRE SPRINKLER SYSTEM(S) SHALL BE FLUSHED
THOROUGHLY BEFORE CONNECTION IS MADE TO EXISTING SYSTEM
STUBOUTS & WITNESSED BY THE PROJECT INSPECTOR.
7. A HYDROSTATIC TEST (200 PSI PRESSURE FOR 2 HRS. OR @ 50 PSI IN
EXCESS OF THE MIN. STATIC PRESSURE WHEN IT IS IN EXCESS OF 150 PSI)
SHALL BE WITNESSED BY THE PROJECT INSPECTOR PRIOR TO COVERING
PIPING JOINTS.
8. A 3' CLR SPACE SHALL BE MAINTAINED AROUND THE CIRCUMFERENCE OF
FIRE HYDRANTS EXCEPT AS OTHERWISE REQ OR APPROVED PER THE
APPLICABLE CODES.
9. THRUST BLOCKS SHALL BE PROVIDED WHEREVER PIPE CHANGES
DIRECTION.
10. ALL PIPE SHALL BE UL LISTED FOR FIRE SERVICE SYSTEMS, CLASS 200 MIN.
11. FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED W /I 100' FROM A
PUBLIC FIRE HYDRANT PER THE APPLICABLE STANDARDS AND CODES.
12. FIRE SPRINKLER RISER SHALL BE LOCATED WITHIN 5 FT OF THE EXT WALL
(OR AS REQ BY THE AHJ) AND TERMINATE 6" ABV FF
13. AN ALL-WEATHER FIRE ACCESS ROAD SHALL BE IN PLACE BEFORE ANY
COMBUSTIBLE MATERIALS ARE PLACED ON THE SITE OR AS REQUIRED BY
THE AHJ.
14. STORAGE, DISPENSING, OR USE OF ANY FLAMMABLE & COMBUSTIBLE
LIQUIDS, FLAMMABLE & COMPRESSED GASES & OTHER HAZARDOUS
MATERIALS SHALL COMPLY W/ THE APPLICABLE CODES.
15. EXIT SIGNS SHALL BE POSTED OVER EXIT DOORS & DIRECTIONAL EXIT
SIGNS SHALL BE LOCATED TO DIRECT PERSONS TOWARD EXIT DOORS.
16. EXIT SIGNS SHALL BE SELF-LUMINOUS TYPE OR ELECTRONICALLY
ILLUMINATED & ENERGIZED FROM SEPARATE CIRCUITS, ONE OF W HICH
SHALL BE FROM STORAGE BATTERIES OR AN ON-SITE GENERATOR, FOR A
DURATION OF 90 MINUTES PER THE APPLICABLE CODES.
17. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF
A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.
18. ACCESS GATE(S) SHALL BE OPENABLE W / FIRE DEPT MASTER KEY FROM
THE EXTERIOR.
19. CURBS ALONG FIRE LANES SHALL BE PAINTED SAFETY RED & MARKED "FIRE
LANE NO PARKING" W/ 3" WHITE LETTERS ON THE TOP OF CURBING EVERY
30' AS INDICATED ON THE APPROVED DRAWINGS.
20. APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR BLDG IN
SUCH A POSITION AS TO BE PLAINLY VISIBLE & LEGIBLE FROM THE STREET
OR ROAD FRONTING THE PROPERTY PER THE APPLICABLE CODES.
21. PROVIDE PERMANENT OR TEMPORARY STANDPIPES WHILE BUILDING IS
UNDER CONSTRUCTION PER THE APPLICABLE CODES.
22. PROVIDE FIRE EXTINGUISHERS PER APPLICABLE STANDARDS AND CODES.
APPLICABLE CODES AND STANDARDS
2024 INTERNATIONAL BUILDING CODE (IBC)
2024 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2024 NATIONAL ELECTRIC CODE (NEC)
2024 INTERNATIONAL FIRE CODE
2012 TEXAS ACCESSIBILITY STANDARDS, INCLUSIVE OF ALL TECHNICAL
MEMORANDA. (TAS)
1. ALL CONSTRUCTION & MATERIALS SHALL BE AS SPECIFIED & IN ACCORDANCE
WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS & THE CONTRACT
DOCUMENTS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF
ALL NEW CONSTRUCTION ON THE SITE.
3. THE CONTRACTOR IS RESPONSIBLE FOR ALL EXG SURVEY MONUMENTS WHICH
MAY BE DISTURBED THROUGH CONSTRUCTION ACTIVITIES DEEMED NECESSARY
FOR PRESERVATION BY THE CIVIL ENGINEER. IF SUCH MONUMENTS WERE
DISTURBED, THE APPLICANT SHALL HAVE A LICENSED LAND SURVEYOR
QUALIFIED CIVIL ENGINEER REESTABLISH ANY SUCH MONUMENTATION
DAMAGED OR DESTROYED DURING THE CONSTRUCTION OF THE PROJECT &
SUBMIT "PRELIMINARY CORNER RECORDS" TO THE CIVIL ENGINEER AFTER
REPLACEMENT. AFTER APPROVAL BY THE CIVIL ENGINEER, THE APPLICANT
SHALL FILE THE CORNER RECORDS WITH THE COUNTY SURVEYOR. PRIOR TO
THE EXONERATION OF ANY SECURITY, EVIDENCE OF SUCH FILING SHALL BE
FURNISHED TO THE CIVIL ENGINEER.
4. THE CONTRACTOR IS RESPONSIBLE TO INSURE THAT TRUCK ROUTES SHALL BE
STEERED AWAY FROM RESIDENTIAL AREAS.
5. THE CONTRACTOR SHALL ENSURE THAT TRUCKS HAULING DIRT ON PUBLIC
ROADS TO & FROM THE SITE SHALL BE COVERED OR W ILL MAINTAIN A 6"
DIFFERENTIAL BETWEEN THE MAX HGT OF ANY HAULED MATERIAL & THE TOP OF
THE HAUL TRAILER. HAUL TRUCK DRIVERS SHALL WATER THE LOAD PRIOR TO
LEAVING THE SITE TO PREVENT SOIL LOSS DURING TRANSPORT.
6. THE CONTRACTOR SHALL ENSURE THAT GRADED SURFACES USED FOR OFF
ROAD PARKING, MATERIALS LAY-DOWN, OR AWAITING FUTURE CONSTRUCTION
SHALL BE STABILIZED FOR DUST CONTROL AS NEEDED. FREQUENTLY
ACCESSED UNPAVED AREAS SHALL BE PAVED AS EARLY AS POSSIBLE TO
MINIMIZE DIRT TRACKOUT TO PUBLIC RIGHTS-OF-WAY.
7. THE CONSTRACTOR SHALL COORDINATE ANY LANE CLOSURES OR DETOURS
WITH THE CITY/COUNTY. FLAG PERSONS & APPROPRIATE TRAFFIC CONTROL
DEVICES SHALL BE USED AS NEEDED TO MINIMIZE CONSTRUCTION ACTIVITY
INTERFERENCE WITH OFF-SITE-TRAFFIC.
8. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & SITE CONDITIONS BEFORE
STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT
DOCUMENTS OR BETWEEN THE CONTRACT DOCUMENTS & EXISTING
CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO
PROCEED.
9. SHOULD A CONFLICT OCCUR BETWEEN DWGS & SPECIFICATIONS, THE MORE
COSTLY CONDITION SHALL TAKE PRECEDENCE, UNLESS A WRITTEN DECISION
FROM THE ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A
CLARIFICATION OR ALTERNATE METHOD AND/OR MATERIALS.
10. THE CONTRACTOR SHALL CONFINE HIS OPERATION ON THE SITE TO AREAS
PERMITTED BY OWNER.
11. THE JOBSITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION FREE OF
DEBRIS & LITTER & SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY
MATERIALS OR EQUIPMENT. EACH SUBCONTRACTOR IMMEDIATELY UPON
COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL TRASH &
DEBRIS AS A RESULT OF HIS OPERATION.
12. ALL MATERIAL STORED ON THE SITE SHALL BE PROPERLY STACKED &
PROTECTED TO PREVENT DAMAGE & DETERIORATION. FAILURE TO PROTECT
MATERIALS MAY BE CAUSE FOR REJECTION OF WORK.
13. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, AND/OR PATCHING OF HIS
WORK THAT MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER
PROPERLY & SHALL NOT ENDANGER ANY OTHER WORK BY CUTTING,
EXCAVATING, OR OTHERWISE ALTERING THE TOTAL WORK OR ANY PART OF IT.
ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND SURFACES, CUT
OR DAMAGED IN EXECUTION OF WORK, SHALL BE DONE WITH APPLICABLE
MATERIALS SO THAT SURFACES REPLACED W ILL, UPON COMPLETION, MATCH
SURROUNDING SIMILAR SURFACES.
14. STRUCTURAL OBSERVATION WILL BE PERFORMED BY THE STRUCTURAL
ENGINEER. WHEN REQUIRED, A STATEMENT IN WRITING SHALL BE GIVEN TO THE
BUILDING OFFICIAL, STATING THAT THE SITE VISITS HAVE BEEN MADE &
WHETHER OR NOT ANY OBSERVED DEFICIENCIES HAVE BEEN CORRECTED TO
CONFORM TO THE APPROVED PLANS & SPECIFICATIONS.
15. SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITAL ITEMS SHALL BE SUBMITTED
TO THE ARCHITECT OR ENGINEER OF RECORD, WHO SHALL REVIEW THEM &
RETURN THEM TO THE CONTRACTOR (WITH A NOTIFICATION INDICATING THAT
THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED & THAT THEY
HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF
THE BUILDING) FOR PLAN CHECK APPROVAL. THE DEFERRED SUBMITTAL ITEMS
SHALL NOT BE INSTALLED UNTIL THEIR DESIGN & SUBMITTAL DOCUMENTS HAVE
BEEN APPROVED BY THE AUTHORITY HAVING JURISDICTION.
16. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL
CONCEALED SPACES, VOIDS, ATTICS, ETC. VERIFY TYPE REQ WITH ARCHITECT
PRIOR TO INSTALLATION.
17. NO PORTION OF WORK REQUIRING A SHOP DWG OR SAMPLE SUBMISSION SHALL
BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE
ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE
WITH CORRECTED SHOP DW GS. AND SAMPLES.
18. DIMENSIONS:
A. ALL DIMS SHALL TAKE PRECEDENCE OVER SCALE.
B. ALL DIMS ARE TO FACE OF STUD / CONCRETE / MASONRY UNO
C. CLG HGT DIMS ARE FROM FACE OF SLAB TO FACE OF FIN CLG MATERIAL UNO
19. DO NOT SCALE DRAWINGS
20. PROVIDE ALL NECESSARY BLOCKING, BACKING, & FRAMING FOR LIGHT
FIXTURES, ELECTRIC UNITS, AC EQUIP, RECESSED ITEMS, AND ALL OTHER ITEMS
AS REQUIRED.
21. WHERE LARGER STUDS OR FURRING ARE REQ TO COVER PIPING AND
CONDUITS, THE LARGER STUD SIZE OR FURRING SHALL EXTEND THE FULL
SURFACE OF THE WALL WIDTH AND LENGTH WHERE THE FURRING OCCURS,
UNO.
22. ALL DOORS SHALL BE OPERABLE FROM THE INSIDE W/O THE USE OF A KEY OR
SPECIAL KNOWLEDGE OF EFFORT. EXIT SIGNS SHALL BE PROVIDED AT ALL EXITS
AS REQ BY THE APPLICABLE CODES. ALL DOOR SWINGS SERVING AN OCCUPANT
LOAD OF 50 OR GREATER SHALL SWING IN THE DIRECTION OF TRAVEL.
23. ALL GLASS AND GLAZING SHALL COMPLY WITH THE APPLICABLE CODES.
24. WALL AND CLG MATERIALS SHALL NOT EXCEED THE FLAME SPREAD
CLASSIFICATIONS IN THE APPLICABLE CODES.
25. SURVEYORS CERTIFICATE REQUIRED PRIOR TO FINAL COMPLETION.
26. THE CONTRACTOR SHALL COMPLY WITH THE APPLICABLE CODES FOR FIRE
SAFETY DURING CONSTRUCTION AND DEMOLITION.
R e v is io n
D a te
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
D
/2
/2
C
D
/1
/2
C D
/1
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
1/8" = 1'-0"
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
S A
IS
D
S A
IS
D
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
GENERAL PROJECT
INFORMATION
G0.20
S A
IS
D
W A
R E
H O
U S
E R
E P
A
IR
Checker
Secondary Project #
PROJECT DIRECTORYVICINITY MAP
PROJECT SCOPE
LIMIT OF W ORK
DEFERRED APPROVALS
ABBREVIATIONSSYMBOLS
SHEET INDEX
I S
S U
E D
A T
E
S H
E E
T N
U M
B E
R
SHEET NAME
GENERAL
05/13/2026 G0.00 COVER SHEET
03/20/20206 G0.20 GENERAL PROJECT INFORMATION
03/20/20206 G0.30 ACCESSIBILITY DETAILS
TBD G2.01 CODE ANALYSIS
ARCHITECTURE
03/20/20206 A1.01 DEMOLITION PLAN
03/20/20206 A2.01 PROPOSED PLANS
03/20/20206 A3.01 EXTERIOR ELEVATION & WALL SECTION
RESPONSIBILITY FOR JOB SITE SAFETY
FIRE AND LIFE SAFETY NOTES
APPLICABLE CODES
CONSTRUCTION NOTES
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C T
05/13/2026
IS
SU
E D
AT
E
SH
EE
T N
U M
BE
R
SH
EE
T N
AM
E
GENERAL
5/13/2026 G0.00 COVER SHEET
5/13/2026 G0.20 GENERAL PROJECT INFORMATION
5/13/2026 G0.30 ACCESSIBILITY DETAILS
5/13/2026 A1.01 DEMOLITION PLAN
5/13/2026 A2.01 PROPOSED PLANS
5/13/2026 A3.01 EXTERIOR ELEVATION & WALL SECTION
5/13/2026 S0.01 GENERAL NOTES
5/13/2026 S0.02 SPECIAL INSPECTIONS
5/13/2026 S2.01 FOUNDATION PLAN AND DETAILS
5/13/2026 S2.02 ROOF FRAMING PLAN AND DETAILS
5/13/2026 E0.1 GENERAL NOTES & ABBREVIATIONS
5/13/2026 E1.1 ELECTRICAL DEMOLITION SITE PLAN
5/13/2026 E1.2 ELECTRICAL SITE PLAN
5/13/2026 E2.1 ELECTRICAL FLOOR PLANS
5/13/2026 E2.2 ELECTRICAL FLOOR PLANS
5/13/2026 E3.1 ELECTRICAL ONE LINE DIAGRAM
SHEET INDEX
ARCHITECTURE
STRUCTURE
ELECTRICAL
48" MIN 48" MIN
48" MIN
(A) (B)
(C)
TAS 404.2.6
/4
/4
/2
/4
M
A X
TAS 303.3
TAS 303.2
NOTE: ALIGN CENTER OF ALL WALL SWITCHES & WALL DEVICES @ CENTERLINES U.N.O.
WALL SWITCHES,
ELECTRICAL DEVICES &
THERMOSTAT WHERE
OCCURS; PROVIDE
BRIDGING FRAME AS
NEEDED
ELECTRICAL OUTLET
WHERE OCCURS1
A .F
.F
U .N
.O .4
A .F
.F
M A
X
TAS 308
M
A X
X
TAS 307.4
GUARDRAIL OR
OTHER BARRIER
M
IN
18" MIN
M
IN
12" MIN
M
IN
36" MIN 6
M
IN
M
IN
22" MIN
M
IN
22" MIN
M
IN
24" MIN
M
IN
24" MIN
M
IN
24" MIN
(A)
FRONT APPROACH, PULL SIDE
(C)
FRONT APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND LATCH
(B)
FRONT APPROACH, PUSH SIDE
(D)
HINGE APPROACH, PULL SIDE
(G)
HINGE APPROACH, PUSH SIDE, DOOR
PROVIDED WITH BOTH CLOSER AND LATCH
(F)
HINGE APPROACH, PUSH SIDE
(H)
LATCH APPROACH, PULL SIDE
(J)
LATCH APPROACH, PUSH SIDE
(K)
LATCH APPROACH, PUSH SIDE, DOOR
PROVIDED WITH CLOSER
ADD 6 INCHES AT
EXTERIOR SIDE OF
EXTERIOR DOOR.
TAS 404.2.4.1
M
IN
18" MIN
X
(A) PULL SIDE (B) PUSH SIDE
M
IN
X
(C) PUSH SIDE, DOOR
PROVIDED WITH
BOTH CLOSER AND
LATCH
M
IN
X
12" MIN
TAS 404.2.4.3
M
IN
18" MIN
MIN.
12"
(U.N.O.)
4" F.O.F.
PULL SIDE
PUSH SIDE
FRONT APPROACH
PROVIDE THIS
ADDITIONAL SPACE IF
DOOR IS EQUIPPED
WITH BOTH A LATCH
AND A CLOSER
FRONT APPROACH
TAS 404.2.3 & TAS 404.2.4.1
32" MIN CLR
M
IN
M
A X
M
A X
UNOBSTRUCTED FORWARD REACH
OBSTRUCTED HIGH FORWARD REACH OBSTRUCTED HIGH FORWARD REACH
20" MAX
M
A X
>20"-25" MAX
TAS 308.2.1 & TAS 308.2.2
X
0'-4"MAX
X
TAS 307.2
M
IN
M
A X
M
A X
M
A X
UNOBSTRUCTED SIDE REACH
OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH
M
A X
0'-10"MAX.
0'-10"MAX. >10"-24" MAX
M
A X
TAS 308.3.2
T O
H A
N D
L E
O R
C O
N T
R O
L S
M
A X
M
A X
FIRE EXTINGUISHER
CABINET
(SURFACE MOUNTED -
PROTRUDING <= 4")
FIRE EXTINGUISHER
CABINET
(RECESSED)
L E
V E
R H
A N
D L
E
P U
L L
H A
N D
L E
P
A N
IC
E
X
IT
P U
S H
P L
A T
E
EXIT
SIGNAGE
EXIT LIGHTS
DOOR HARDWARE
LIGHT SWITCH
THERMOSTAT PUSH
BUTTON PULL
STATION CARD
READER CALL
SWITCH DOOR
SWITCH
GROUP & ALIGN
WALL MOUNTED
LIGHT SWITCHES,
THERMOSTATS,
SPEAKER VOLUME
CONTROL, ETC.
C E
N T
E R
L
IN
E O
F B
O X
0'-4"
ELECTRICAL,
TELEPHONE OR
DATA OUTLET
ELECTRICAL,
TELEPHONE OR
DATA OUTLET
O F
B O
X
C
L
CHBD, MKBD & TKBD (MEASURED FLR. TO
BOTT. OF BOARD)
NOTE: EXCEPT WHERE
THERE IS A SIDELITE
NEXT TO THE DOOR,
LOCATE CONTROLS ON
ADJ. WALL CLOSEST
TO THE DOOR, CLEAR
OF DOOR SWING,
U.O.N.
TAS 307.2, TAS 308.2.1, TAS 308.3.1
R e v is io n
D a te
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
D
/2
/2
C
D
/1
/2
C D
/1
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
As indicated
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
S A
IS
D
S A
IS
D
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
ACCESSIBILITY DETAILS
G0.30
S A
IS
D
W A
R E
H O
U S
E R
E P
A
IR
Checker
Secondary Project #
08DOOR CLEARANCES - DOORS IN SERIES
23CHANGES IN LEVEL
18TYPICAL DEVICE INSTALLATION22VERTICAL CLEARANCE
05DOOR CLEARANCES13RECESSED DOOR CLEARANCES
14TYPICAL CLEARANCES AT DOOR
15ACCESSIBLE FORW ARD REACH
REQUIREMENTS
ACCESSIBLE PATH OF TRAVEL
PROTRUDING OBJECT LIMITS
19ACCESSIBLE SIDE REACH
REQUIREMENTS
1/2" = 1'-0"
G0.30 16ACCESSIBLE MOUNTING HEIGHTS
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C
1. BACKGROUND DRAWINGS ARE BASED ON ORIGINAL CONSTRUCTION
DOCUMENTS, NOT AS-BUILT DRAWINGS. PLEASE VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES
TO THE ARCHITECT.
2. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ALL
DISCREPANCIES TO THE ARCHITECT.
3. PROTECT ALL AREAS NOT SCHEDULED FOR DEMOLITION.
4. ALL PHYSICAL STRUCTURE AND FEATURES OF BUILDING THAT ARE NOT
ILLUSTRATED BY 'DASHED' LINE, OR OTHERWISE SPECIFICALLY DESIGNATED
TO BE REMOVED, SHALL REMAIN 'AS IS'.
5. WHERE NEW WORK ABUTS EXISTING, GENERAL CONTRACTOR AND ALL
AFFECTED SUBCONTRACTORS SHALL STRIVE TO CREATE UNNOTICEABLE
SURFACES / PLANE TRANSITIONS.
6. EXISTING CONDITIONS DAMAGED OR REMOVED AS A RESULT OF ALL WORK
REQUIRED TO BE DONE UNDER THIS CONTRACT SHALL BE PREPARED OR
REPLACED TO THE ORIGINAL CONDITION AND FINISHED TO MATCH
ADJACENT SURFACES.
7. REPAIR AND/OR REPLACE DAMAGE TO ANY PARTITIONS NOT DESIGNATED TO
BE DEMOLISHED DURING DEMOLITION AND/OR CONSTRUCTION. ALL
SURFACES THAT ARE SCHEDULED TO RECEIVE NEW FINISHES SHALL BE
PREPARED ACCORDINGLY AND APPROPRIATELY. REFER TO FINISH PLAN.
8. EACH AREA OF DEMOLITION IS TO BE CLEAR OF DEBRIS AND IS TO BE SWEPT
CLEAN. METHOD OF DEBRIS REMOVAL MUST BE IDENTIFIED BY THE
CONTRACTOR AND APPROVED BY THE BUILDING OWNER.
9. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OR TAPING OF EQUIPMENT,
MARKER BOARDS, MECHANICAL / ELECTRICAL / TECHNOLOGY EQUIPMENT,
CASEWORK, AND ALL MOUNTED EQUIPMENT LOCATED ON WALLS TO BE
PAINTED.
10. ALL EXISTING FIRE SYSTEM DEVICES AND SPRINKLER HEADS TO REMAIN.
COORDINATE WITH NEW CEILING TILE.
11. ALL EXISTING TECHNOLOGY/SECURITY DEVICES TO REMAIN. COORDINATE
WITH NEW WORK.
SCOPE OF WORK
EXISTING NON-RATED WALL TO REMAIN
EXISTING CONCRETE WALL TO REMAIN
CONCRETE WALL TO BE DEMOLISHED
MILLWORK TO BE DEMOLISHED
WALL TO BE DEMOLISHED
NOT IN SCOPE OF WORK
DOOR TO BE DEMOLISHED
EXISTING GYP. CEILING
TO REMAIN
DEMOLISH 2 X 4 ACT
CLG, SEE NOTE #A
EXPOSED TO BOTTOM OF DECKEX
CONC. WALL TO
BE DEMOLISHED
STEEL COLUMN TO
BE DEMOLISHED,
REF. STRUCTURE
EXISTING WALL TO
BE DEMOLISHED
AND REMOVE
WALL BASE
22'-0"
IDF/OFFICE
WAREHOUSE
BAY
EXISTING WALL TO BE
DEMOLISHED
REMOVE DAMAGED
FLOOR TILES (EST. 25%)
AND W ALL BASE IN THIS
ROOM
A1.01
WAREHOUSE
BAY
OFFICE
SPACE
T/R
IDF/OFFICE
WAREHOUSE
BAYS
WAREHOUSE
BAY
IDF/OFFICE
EX
PREPARE ALL MECHANICAL,
LIGHTING, TECHNOLOGY, AND
FIRE PROTECTION SYSTEMS TO
RECEIVE THE NEW CEILING,
REF. ELECTRICAL
REMOVE AND REINSTALL CEILING
TILES, GRID, AND ALL CEILING
MOUNTED SYSTEMS IN THIS AREA
AS REQUIRED TO ACCOMMODATE
INSTALLATION OF NEW
STRUCTURAL ELEMENTS.
REMOVE DAMAGED CEILING TILES
AND GRID (EST. 25%), AND PREPARE
THE AREA FOR INSTALLATION OF THE
NEW CEILING TILE SYSTEM. PROTECT
ALL EXISTING CEILING MOUNTED
SYSTEMS THAT WILL BE REINSTALLED
AT THE NEW CEILING.
EXISTING FIXTURES TO REMAIN
DEMO EXISTING FIXTURES,
SALVAGE AND RETURN TO
OWNER.
REF. ELECTRICAL
A 1.01
A 1.01
A 1.01
1" = 20'-0"
A1.01 0500 - SEGMENT A FLOOR PLAN
KEYPLAN
R e v is io n
D a te
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
AB
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
D
/2
/2
C
D
/1
/2
C D
/1
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
As indicated
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
S A
IS
D
S A
IS
D
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
DEMOLITION PLAN
A1.01
S A
IS
D
W A
R E
H O
U S
E R
E P
A
IR
Checker
Secondary Project #
KEYNOTES
GENERAL NOTES
LEGEND
1/8" = 1'-0"
A1.01
0601 - FLOOR DEMOLITION PLAN
1/8" = 1'-0"
A1.01
0701 - FLOOR DEMOLITION REFLECTED CEILING PLAN
1 1/2" = 1'-0"
A1.01 13IDF OFFICE
1 1/2" = 1'-0"
A1.01 17W AREHOUSE BAY 1
1 1/2" = 1'-0"
A1.01
18W AREHOUSE BAY 1
1 1/2" = 1'-0"
A1.01
14IDF OFFICE
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C
SA2U
WALL TYPE. LETTER INDICATES WALL TYPE. SEE A8.11.
STUD SIZE. NUMBER INDICATES STUD SIZE. SEE A8.11.
STUD WALL CONSTRUCTION
NOT IN SCOPE OF WORK
SCOPE OF WORK
2 X 4 ACT CLG, SEE
DETAIL XX/XXX
CENTER DEVICES ON CLG TILE - TYP
INCLUDED BUT NOT LIMITED TO THE FOLLOWING:
SPRINKLER, FIRE STROBE, SPEAKERS, DAYLIGHT &
OCCUPANCY SENSORS.
9'-0"
XXX-1
TYP CLG HEIGHT, UNO
TYP CLG TYPE, UNO
EQ EQ
E Q
E Q
EXISTING NON-RATED WALL TO REMAIN
EXISTING CONCRETE WALL TO REMAIN
CONCRETE WALL TO BE DEMOLISHED
WALL TO BE DEMOLISHED
1. ALL WALLS TO BE WALL TYPE "SE4", UNO
2. REFER TO G0.30 FOR TYP CLEARANCE @ DOOR LOCATIONS.
3. ALL NEW INTERIOR WALLS TO RECEIVE TAPE, LEVEL, FINISH, PRIMER AND
TWO COATS OF PAINT (OR AS NECESSARY FOR A UNIFORM FINISH).
4. FOR TYP SWITCH & DEVICE ALIGNMENTS, REFER TO G0.30
5. BACKGROUND DRAWINGS ARE BASED ON ORIGINAL CONSTRUCTION
DOCUMENTS, NOT AS-BUILT DRAWINGS. PLEASE VERIFY ALL CONDITIONS
AND DIMENSIONS PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES
TO THE ARCHITECT.
6. EXISTING CONDITIONS DAMAGED OR REMOVED AS A RESULT OF ALL WORK
REQUIRED TO BE DONE UNDER THIS CONTRACT SHALL BE REPAIRED OR
REPLACED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT
SURFACES.
7. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND REPORT ALL
DISCREPANCIES TO THE ARCHITECT.
8. WHERE NEW W ORK ABUTS EXISTING, GENERAL CONTRACTOR AND ALL
AFFECTED SUBCONTRACTORS SHALL STRIVE TO CREATE UNNOTICEABLE
SURFACES / PLANE TRANSITIONS.
9. UPON COMPLETION OF ALL REMODEL OPERATIONS, GENERAL
CONTRACTORS SHALL REMOVE ALL PAINT SPATTERS FROM ALL EXISTING
EXTERIOR CURTAIN WALL ALUMINUM (INTERIOR SURFACES), AS WELL AS ALL
EXISTING INTERIOR GLAZED AND FRAMED WINDOW AND SIDELIGHT
ASSEMBLIES, ETC. ALL EXISTING ALUMINUM FRAMING SURFACES SHALL BE
COMPLETELY AND THOROUGHLY WIPED CLEAN AND FREE OF DRYWALL
DUST AND CLEANING RESIDUE, TO THE SATISFACTION OF THE OWNER AND
ARCHITECT.
10. FLOOR PLAN DIMENSIONS ARE FROM COLUMN CENTERLINES, FACE OF
CONCRETE AND / OR MASONRY WALLS, OR FACE OF METAL STUDS. U.N.O.
EXTERIOR WALLS ARE DIMENSIONED TO THE FACE OF THE STRUCTURAL
BACKUP WALL AND STUDS OR FACE OF CONCRETE.
11. PROVIDE RATED BLOCKING AS REQUIRED FOR ANY WALL MOUNTED ITEMS
OR ACCESSORIES. PROVIDE 2X BLOCKING AS REQUIRED FOR PROPER
SUPPORT OF ALL CEILING MOUNTED EQUIPMENT.
12. ALL EXPOSED STEEL AND GALVANIZED STEEL TO BE PAINTED, COORDINATE
FINAL COLOR SELECTIONS WITH ARCHITECT.
13. ANY DISCREPANCIES BETWEEN STRUCTURAL, ARCHITECTURAL, OR MEP
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
14. ALL CLG HEIGHT TO MATCH EXISTING HEIGHT.
15. FOR ALL LIGHTING SPECIFICATIONS, REFER TO ELECTRICAL
16. CONFIRM MTG HEIGHTS W/ ARCHITECT IN FIELD PRIOR TO INSTALLATIONS
FOR ALL NON -RECESSED FIXTURES
17. REFER TO MECHANICAL FOR SUPPLY & RETURN AIR SPECIFICATIONS
18. REFER TO TECHNOLOGY FOR ADDL CLG ELEMENTS
A
WAREHOUSE
BAY
IDF/OFFICE
22'-0"
6'-8" 15'-0" 15'-0"
B
2 3
4" 11'-4" 10'-4"
/4
A3.01
A3.01
A3.01
OFFICE
SPACE
A3.01
IDF CABINET, PROVIDE
WOOD BLOCKING OR
PLYWOOD BACKING AS
REQUIRED TO SUPPORT
INSTALLATION.
REF. ELECTRICAL
A
B
2 3 4
WAREHOUSE
BAY
9' - 0"
ACT-1
FIELD VERIFY
IDF/OFFICE
FIELD VERIFY
9' - 0"
ACT-1
NOTE: REF. MEPT FOR
CEILING BASED SYSTEMS
NEW LIGHT
FIXTURES,
REF. ELECTRICAL
S L
O P
E S
L O
P E
EXISTING ROOF SYSTEM TO REMAIN
EXISTING GUTTER TO REMAIN
NEW GUTTER TO MATCH
EXISTING IN COLOR AND PROFILE
PREPARE TO RECEIVE NEW GUTTER
22'-0"
A3.01
REPLACE DAMAGED FLOOR
TILES (EST. 25%) AND WALL
BASE, MATCH EXISTING IN
COLOR, TEXTURE AND
PROFILE IN THIS ROOM
REPLACE WALL BASE,
MATCH EXISTING IN COLOR,
TEXTURE AND PROFILE
ALONG THIS WALL
FLOOR TRANSITION
TO REMAIN
1/8" = 1'-0"
A2.01 07ROOF PLAN
KEYPLAN
R e v is io n
D a te
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
AB
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
D
/2
/2
C
D
/1
/2
C D
/1
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
1/8" = 1'-0"
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
S A
IS
D
S A
IS
D
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
PROPOSED PLANS
A2.01
S A
IS
D
W A
R E
H O
U S
E R
E P
A
IR
Checker
Secondary Project #
KEYNOTES
LEGEND
GENERAL NOTES
1/8" = 1'-0"
A2.01 0501 - FLOOR PLAN
1/8" = 1'-0"
A2.01 1301 - FLOOR FINISHES PLAN
1/8" = 1'-0"
A2.01
0601 - FLOOR REFLECTED CEILING PLAN
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C
EXISTING TILT-UP CONCRETE WALL
TO REMAIN (C-1)
INSULATED METAL PANEL (IMP-1)
01 - FLOOR
0'-0"
DEMO CONC. WALL TO RECEIVE NEW ENVELOPE SYSTEM
22'-0"
EXISTING CONC. WALL TO REMAIN
EXISTING ROOF SYSTEM TO REMAIN
EXISTING GUTTER TO REMAIN
NEW GUTTER TO MATCH
EXISTING IN COLOR AND PROFILE
EXISTING CONC. WALL
TO REMAIN
EXISTING SECURITY DEVICE TO
BE REMOVED, PROPERLY
STORED, AND REINSTALLED
ABOVE GROUND
PVC CONDUIT W/ CIRCUIT TO BE
REPLACED AS REQUIRED, TO MATCH
EXISTING.
REF. ELECTRICAL
A3.01
C-1 IMP-1 C-1
MATCH EXISTING
T.O.S
EXISTING STRAPS TO REMAIN NEW SUPPORT STRAPS TO
MATCH EXISTING IN SHAPE
AND COLOR
EQEQ
TYP.
6'-0"
DS
01 - FLOOR
0'-0"
A
T.O.S
13'-9"
B
FIELD VERIFY
STEEL COLUMN,
REF. STRUCTURE
A3.01
A3.01
F
IE
L D
V E
R
IF
Y
A
B
MIN. 4 PCF COMPRESSED
MINERAL FIBER
SEALANT AND BACKER ROD
EXISTING CONCRETE WALL TO REMAIN.
CONTRACTOR SHALL PREPARE WALL
SURFACE TO RECEIVE IMP-1 PRIOR TO
INSTALLATION, INCLUDING CLEANING AND
REMOVAL OF IRREGULARITIES AS REQUIRED.
PROVIDE STRAIGHT, CLEAN EDGES.
TWO PIECE JAMB EXTRUSION
CAP TO MATCH PANEL COLOR
CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM
FASTENERS W/ BONDED
WASHER AT 12" O.C. PER MANUF.
NEW STEEL COLUMN,
REF. STRUCTURE
EXISTING INT. PARTITION
TO REMAIN
SE4
F
IE
L D
V E
R
IF
Y
ALIGN
4"
STEEL ANGLE AND PLATE,
REF. STRUCTURE
4" INSULATED METAL PANEL
(IMP-1)
R-13 BATT INSULATION
Z-GIRT,
REF. STRUCTURE
NEW DOWNSPOUT TO
MATCH EXISTING PROFILE
AND COLOR,
TO BE CENTERED AT IMP-1
PANEL
A
B
STAINLESS STEEL HIDDEN
FASTENER CLIP PER MANUF.
SET IN BUTYL SEALANT
CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
SE4
A
IR
G A
P
/8
/2
R-13 BATT INSULATION
4" INSULATED METAL PANEL (IMP-1)
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD , TO MATCH
ADJACENT WALL IN COLOR
AND TEXTURE
4" METAL STUD FRAMING
CONTINUOUS SEALANT
CONTINUOUS TRACK TO
MATCH STUD SIZE
STRAP OR BRIDGING
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
AB 2X TREATED BLOCKING
EXISTING ROOF SYSTEM
EXISTING METAL FLASHING,
REMOVE AND REPLACE AS NEEDED
NEW GUTTER TO MATCH
EXISTING PROFILE AND COLOR
CAP TRIM W/ POP RIVETS AT
8" O.C. SET IN CONTINUOUS
BUTYL SEALANT
CONTINUOUS BUTYL SEALANT
FASTENERS W/O BONDED WASHER
PER MANUF.
STAINLESS STEEL FASTENER
CLIP PER MANUF. SET CLIP IN
BUTYL SEALANT
JOINT FILLER GASKET PER
MANUF.
VINYL FACED LAMINATED
INSULATION W/ W IRE
SUPPORT, REMOVE AND
REINSTALL AS NEEDED
STEEL BEAM,
REF. STRUCTURE
STEEL COLUMN,
REF. STRUCTURE
4" INSULATED METAL PANEL (IMP-1)
HIGH TEMP SELF ADHEARING
MEMBRANE FLASHING
R-13 BATT INSULATION
EAVE STRUT,
REF. STRUCTURE
MATCH EXISTING
T.O.S
Z-GIRT,
REF. STRUCTURE
REF. FLOOR PLAN FOR
WALL TYPE AND LOCATION
01 - FLOOR
0'-0"
AB
CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
FASTENER W /O WASHER
AT 12" O.C., PER MANUF.
STEEL ANGLE W/ MIN. 3" VERT.
LEG, SET IN CONTINUOUS BED
OF SEALANT
REF. STRUCTURE
BASE TRIM W/ POP RIVETS AT 8" O.C.,
COLOR TO MATCH PANEL
STEEL COLUMN,
REF. STRUCTURE
EXISTING GRADE TO REMAIN AS IS
EXISTING FOUNDATION TO REMAIN,
REF. STRUCTURE
5/8" 4"
AIR GAP
4" 4 1/2" 4"
4" INSULATED METAL PANEL (IMP-1)
R-13 BATT INSULATION
SE4
PRE-FINISHED METAL FLASHING IN A
CONTINUOUS BED OF SEALANT PER
MANUF. COLOR TO MATCH PANEL
A
B
EXISTING CONCRETE WALL
TO REMAIN.
MIN. 4 PCF COMPRESSED
MINERAL FIBER
SEALANT AND BACKER ROD
TWO PIECE JAMB EXTRUSION
CAP TO MATCH PANEL COLOR
CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM
FASTENERS W/ BONDED
WASHER AT 12" O.C. PER MANUF.
PTD. GYP TO ALIGN W/
EXISTING INT. PARTITION.
Z-GIRT,
REF. STRUCTURE
STEEL ANGLE,
REF. STRUCTURE
4" INSULATED METAL PANEL
(IMP-1)
R-13 BATT INSULATION
SE4
SE Walls
WALL
TYPE
STUD
SIZE
SE4 4" STUDS
3" = 1'-0"
A3.01 20W ALL TYPE "SE"
KEYPLAN
R e v is io n
D a te
210-829-1737 Office
1811 South Alamo Street, Suite 100
San Antonio, Texas 78204
AB
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
ARCHITECTURE ENGINEERING INTERIOR DESIGN
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
D e v e lo p e d f o r
Checked By
Scale
Job Number
S u b m it ta l D a te
C
D
/2
/2
C
D
/1
/2
C D
/1
/2
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.
Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.
© LPA, Inc.
As indicated
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
S A
IS
D
S A
IS
D
W S
U M
M
IT
A V
E
S A
N A
N T
O N
IO
T X
EXTERIOR ELEVATION &
W ALL SECTION
A3.01
S A
IS
D
W A
R E
H O
U S
E R
E P
A
IR
Checker
Secondary Project #
KEYNOTES
LEGEND
1/4" = 1'-0"
A3.01 05EXTERIOR ELEVATION
1/2" = 1'-0"
A3.01 17W ALL SECTION
3" = 1'-0"
A3.01 19END W ALL TERMINATION
3" = 1'-0"
A3.01
18PANEL JOINT
3" = 1'-0"
A3.01
07ROOF DETAIL
3" = 1'-0"
A3.01 08LUG DETAIL
3" = 1'-0"
A3.01
12END W ALL TERMINATION
AT
T S
XETE FO
S A
S A
RA FLOWER
S
2 0 5 14
R E G
IS
TE
RED ARCHITE
C
1.
2.
3.
4.
5.
6.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
7.
A.
8.
A.
B.
C.
D.
E.
F.
9.
10.
11.
12.
A.
B.
C.
a.
b.
c.
d.
e.
GENERAL
Authority Having Jurisdiction (AHJ): City of San Antonio Applicable Building Code 2024 International Building Code (IBC), as modified by AHJ. References to industry standards herein shall be the latest edition as adopted by the Applicable Code.
Field Verification: Field verify the existing conditions and dimensions prior to construction. Promptly notify the Architect (Structural Engineer) in case of discrepancies.
Design Intent: Contract Documents indicate the design intent for the structure in its completed state. They do not indicate the method of construction. Promptly notify the Architect (Structural Engineer) prior to proceeding with the Work if the design intent requires further clarification.
Deviations, Modifications and Substitutions to Approved Structural Drawings: Must be accepted in writing by the Architect (Structural Engineer) and approved by AHJ. No deviation, modification or substitution will be accepted via shop drawing review.
When there is a conflict between the general notes, specifications, plans and details the most stringent shall apply.
Procedures of Construction: The contractor is responsible for procedures of construction that comply with national, state and local safety ordinances. Site visits (including Structural Observation) by the Architect (Structural Engineer) do not constitute supervision of the methods of construction.
Protection of Utilities: Locate existing utilities, including those not shown on Contract Documents, and protect them from damage. The contractor bears the expense of repair or replacement of utilities in conjunction with the execution of Work.
Protection of Structure: Provide necessary measures to protect the structure and adjacent buildings during the execution of Work.
Contractor Proposed Revisions: Where a revision of structural design or connection is proposed by the Contractor to accommodate construction tolerances, construction sequence and/or dimension modifications, the Contractor shall retain a structural engineer licensed in the State having jurisdiction to perform design. Submit stamped and signed design drawings and calculations to the Architect (Structural Engineer) for review and to the AHJ for approval.
Erection Plans: Determine phases of Work requiring erection plans according to applicable safety regulations. Maintain certified copies of erection plans at the site during construction.
Shoring, Bracing, and Other Temporary Supports: Design and erect shoring, bracing, and other temporary supports where the structure has not attained design strength and as required for safe erection. Ensure floor, roof, and wall members are securely shored and braced during construction. Provide shoring at elevated beams and slabs supporting concrete or masonry walls during and after the wall pour until the wall attains design strength.
Temporary Loading: Ensure construction loads do not exceed indicated design live load values. Notify affected sub-contractor trades of these design load limits.
Fabrication, Shipment, and Erection of Structural Steel: Ensure stresses occurring during fabrication, shipment, and erection of structural steel are temporary and are less than the design and allowable stress capacities of individual members. Do not impair the full design and load-carrying capacity of members due to fabrication, shipment, or erection. The contractor is responsible for controlling the erection sequence, erection procedure, temperature differentials and weld shrinkage to minimize residue stresses. Provide additional materials for the erection of structural steel, such as temporary bracing and guy cables, as may be necessary at no additional cost.
Remove these materials unless approved in writing by the Owner. Do not tighten bolts in typical beam to column connections for erection purposes.
Securing Reinforcing Steel, Dowels, Anchor Bolts and Embeds: Firmly support and accurately place complying with ACI standards prior to casting concrete or grout in masonry walls. Use ties and support bars in addition to reinforcing steel shown where necessary. No welding of reinforcing steel, including tack welding, is permitted unless otherwise accepted in writing by the Architect (Structural Engineer). Provide plastic or plastic-coated chairs and spacers when resting on exposed surfaces.
Coordination Responsibility: The Contractor is responsible for the coordination of Work, including that of sub-contractor trades.
Core drilling of hardened concrete shall only be done after a specific review by the Architect (Structural Engineer). Core drilling shall not cut any reinforcing. Concrete coverage for reinforcement, as described in these notes, shall be maintained at the locations of cores.
Submittals: Submit to the Architect (Structural Engineer) as indicated on structural drawings and specifications. The General Contractor shall review the submittal for completeness and compliance with Contract Documents prior to submission.
Request for Information (RFI) Submittals: Accompany RFI's with partial structural foundation or framing plans showing the location in question and affected structural members. Copy partial plan from structural drawings and indicate grid line locations and floor level.
Also, provide properly drawn engineering sketches illustrating issues and the Contractor's proposed solutions. Photographs are not acceptable substitutes for engineering sketches.
Contract Documents Use: Review Contract Documents in their entirety before performing structural-related Work and before developing shop drawings. Bring discrepancies to the immediate attention of the Architect (Structural Engineer) before starting Work.
Scaling of Drawings: Not permitted.
Do not reproduce Contract Documents to create shop drawings.
Additional Structural Requirements: See specifications.
Building Geometry: See architectural drawings for building geometry including, but not limited to, top of floor and roof elevations;
depressions; slopes; curbs; drains; trenches; slab and deck edge locations; wall overall dimensions; and size and locations of openings in floors, roof, and walls.
Non-structural Items Requiring Special Provisions: See architectural, mechanical, plumbing, and electrical drawings for non-structural items requiring special provisions during construction. They include but are not limited to, non-structural walls; size and locations of openings and sleeves penetrating structure; size and location of concrete curbs and pads; and size and location of piping, ductwork, and equipment anchorages mounted or suspended from the structure. Verify the exact size and location of equipment with the equipment manufacturer.
Work shown is new unless noted as existing thus, (E).
Materials: Furnish and install in compliance with legally constituted public authorities having jurisdiction, including county and local ordinances and safety orders of the State Industrial Accident Commission, OHSA. The Architect (Structural Engineer) and Owner accept no responsibility for the contractor's failure to comply with these requirements.
Penetrations, Embedments, and Openings in Structural Members: No penetration, embedment, opening, sleeve, pipe, or conduit shall occur in structural members, including footings, slabs, walls, columns, and beams unless specifically shown or indicated on structural drawings.
Typical Details: Details on sheets indicated as typical are applicable throughout the Project wherever the described condition occurs and may or may not be specifically referenced on structural drawings. The contractor is responsible for identifying these details and understanding the extent of their application prior to performing Work. Details not shown or noted shall be similar to those shown for similar construction. The contractor shall submit RFI's for details such as this to the Architect (Structural Engineer) prior to proceeding with work.
Evaluation Report:
References to Evaluation Reports for proprietary materials herein shall be the latest edition as adopted by Authority Having Jurisdiction
(AHJ).
For proprietary structural elements and products, the product is to hold an Evaluation Report in compliance with the applicable code for the product's intended use.
Approved Evaluation Report Agencies:
ICC (ICC-ES)
IAPMO (IAPMO-ES)
OSHPD (OPA / OPM / OSP / OPD)
City Of Los Angeles (COLA/RR) Miami-Dade (NOA)
1.
A.
a.
b.
B.
a.
b.
c.
d.
e.
f.
A.
a.
B.
a.
b.
c.
d.
e.
f.
DESIGN LOADING
Loading and Design Parameters:
Live Load
Floor / Roof Live Load:
Ground Floor: 100 psf Roof: 20 psf
Live Load Reduction:
Floor Live Load of 100 psf and below: General (Section 1607.12.1) Floor Live Load over 100 psf: unreduced Roof Live Load: General (Section 1607.14.1)
Wind Design Parameters Wind Speed Strength level, V: 107 MPH (STRENGTH) Wind Speed Allowable Stress, Vasd 75 MPH (ASD) Risk Category: II Exposure: B Enclosure Classification: Enclosed
Internal Pressure Coefficient, GCPi: +/- 0.18 Components and Cladding Wind Pressure:
EFFECTIVE AREA
ZONE 10 SF 100 SF 500 SF
1 +11.2 +8.0 +6.9 -31.2 -16.9 -9.7 2 +11.2 +8.0 +6.9 -41.2 -22.6 -16.9 3 +11.2 +8.0 +6.9 -54.1 -28.4 -28.4 4 +11.7 +14.0 +12.6 -19.3 -17.6 -14.0 5 +11.7 +14.0 +12.6 -22.6 -17.6 -14.0 Loads indicated in the table are strength-level loads and are indicated in pounds per square foot (psf).
Rain Loads Rain Intensity (15-minute), i: 9.1 (in/hr)
Snow Loads Parameters:
Ground snow load, pg 8 PSF Flat-roof snow load, pf 6 PSF Risk Category: II Snow load importance factor, Is 1.0 Thermal factor, Ct 1.20 Slope factor, Cs 1.00
1.
2.
3.
A.
B.
C.
D.
a.
b.
DEFERRED SUBMITTAL ITEMS ANCHORED OR SUPPORTED BY STRUCTURE
Design Responsibility: Contractor to design and obtain separate AHJ approval for deferred approval items noted on Gx series sheets.
Shop Drawings and Structural Calculations: Submit design plans, details and calculations of deferred submittal items signed and sealed by a registered structural engineer registered in the state having jurisdiction to Architect (Structural Engineer) for acceptance and to AHJ for approval prior to fabrication.
Design: Design components for imposed forces, including lateral restraint, complying with the Applicable Code, Contract Documents, and applicable portions of AISI Specifications. If the building Lateral Force Resisting System (LFRS) is used for lateral restraint, indicate load paths to the building lateral resisting system in the calculations and show the connection forces on the shop drawings.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .