2-Quote.pdf

PDF 816 KB Posted

Attached to
eFemto Installations for new County Buildings
Solicitation number
SS-26-00421
Issued by
Hillsborough County, Florida

About this file

This is a detailed scope of work quote prepared by Source 1 Solutions for Hillsborough County, Florida, for the installation of a Verizon eFemto-based in-building cellular signal enhancement system at Fire Station 21. The project involves turnkey installation of a passive distributed antenna system (DAS) utilizing a Verizon-approved eFemto small cell unit connected to existing customer IP backhaul, with RF coaxial cabling, splitters, and ceiling-mounted service antennas distributed throughout the facility. Installation work includes running coaxial cable through ceiling spaces, mounting passive DAS service antennas on ceiling tiles or pedestals, installing RF splitters and couplers per design specifications, mounting the eFemto unit in a telecommunications or network closet, and connecting the unit to customer-provided power and IP backhaul. Work will be performed during normal business hours throughout multiple building areas including retail sales floors, office spaces, back-of-house areas, and electrical/network closets using ladders and scissor lifts as required.

The quote reflects hardware and installation costs totaling $47,730.55 as a one-time special procurement award. Key pricing components include a SM64-BLC eFemto3 Network Extender unit at $2,999.99, connector assemblies, antennas, and mounting hardware with associated labor. The scope explicitly excludes full-building coverage guarantees, support for carriers other than Verizon, architectural modifications, core drilling, fire-rated penetrations, conduit installation, asbestos abatement, and additional electrical work beyond basic power connection. System performance is contingent upon Verizon provisioning and activation, with the quote including only one post-installation walk test verifying basic signal presence without formal carrier certification or guaranteed performance metrics. Any changes to scope, coverage areas, or antenna configurations after design approval require formal change orders.

View the file

Other files

File Type Posted
1-SS Letter.pdf PDF
3-SS-26-00421 Completed Contract File.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Prepared for: Hillsborough County

Thursday, June 25, 2026

Hillsborough County Fire Station 21

Quote # 005882

Version 1

Prepared by:

Juan Escobedo

P: (727) 538-4114 | E: US.Sales@source1solutions.com

Scope of Work (SOW)

This Scope of Work (SOW) is for the installation of a Verizon eFemto-based In-Building Cellular Signal Enhancement

System utilizing a Passive Distributed Antenna System (DAS). The system is intended to improve Verizon Wireless LTE indoor coverage and capacity within the building for authorized users, including voice, data, and messaging services.

The solution utilizes a Verizon-approved eFemto (small cell) unit as the signal source, which connects to the Verizon core network via the customer’s existing IP backhaul. The eFemto output is passively distributed throughout the facility using coaxial cabling, splitters, and ceiling-mounted service antennas to provide enhanced indoor coverage in designated areas.

Source 1 Technicians will install the following for each building as specified by the approved design:

Installation Scope

• Install RF coaxial cable throughout the ceiling space to support the passive DAS

• Install passive DAS service antennas mounted to ceiling tiles or pedestals as required

• Install RF splitters, couplers, and terminations per RF design

• Install and mount Verizon eFemto unit in an approved telecommunications or network closet

• Connect eFemto unit to existing customer-provided power and IP backhaul

• Label all cabling and components in accordance with industry standards

Work Environment

Work will be performed throughout the building using ladders and/or scissor lifts as required. Work areas may include, but are not limited to:

• Retail sales floor

• Office and cubicle areas

• Back-of-house and receiving/stocking areas

• Electrical and network closets

• Above accessible ceiling spaces

All cabling and antenna installation will be performed during normal business hours unless otherwise specified. The eFemto unit installation will occur in a secure IT or network room and can be completed during normal business hours.

Assumptions & Caveats for Verizon eFemto / Passive DAS Installation Quote

Scope of Coverage

This quote includes coverage only for areas identified in the approved RF design. Full-building cellular coverage is not guaranteed unless explicitly stated in the design documents. Coverage is limited to Verizon Wireless services only; no other carriers are supported.

Carrier Dependency

System performance is dependent on Verizon provisioning, approval, and activation of the eFemto unit. Any delays or limitations imposed by Verizon (including device authorization, IP configuration, or capacity restrictions) are outside the installer’s control.

Quote #005882 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 2 of 6

Passive DAS Limitations

This design utilizes a passive DAS architecture with no active amplification or remote units. Signal levels are dependent on eFemto output power, antenna spacing, cable lengths, and building materials. Future expansion may require redesign, additional antennas, or conversion to an active or hybrid DAS.

Near-Far Effect

Due to the nature of passive DAS systems, Near-Far effects may occur if antennas are unevenly spaced or if environmental conditions change. The design assumes proper antenna isolation and balance at the time of installation; however, changes to walls, shelving, or occupancy may affect performance.

RF Propagation Assumptions

RF propagation assumptions are based on typical commercial construction materials. Materials such as metallic shelving, low-E glass, concrete, or dense mechanical spaces may reduce coverage and require additional antennas or redesign. This quote does not include RF mitigation for shielded rooms, elevator shafts, stairwells, or exterior areas unless specifically noted.

Antenna Mounting Assumptions

Service antennas are assumed to be ceiling-mounted in accessible areas with standard ceiling heights. High ceilings, hard-lid ceilings, or restricted-access areas may require additional labor and materials. No decorative concealment or architectural modifications are included unless explicitly stated.

Power and IP Backhaul

Customer will provide: • Dedicated, code-compliant electrical power for the eFemto unit

• Active IP backhaul meeting Verizon eFemto bandwidth and latency requirements

Any additional electrical work, new circuits, UPS systems, or network upgrades are excluded unless noted and will require a change order.

Pathways and Construction

Existing cable pathways and ceiling access are assumed to be available and accessible. Core drilling, fire-rated penetrations, conduit installation, or asbestos abatement are not included unless specifically stated. Any unforeseen construction obstacles will be addressed via change order.

Testing and Acceptance

This quote includes one post-installation walk test to verify basic Verizon signal presence and usability. Formal carrier certification or guaranteed performance metrics (RSSI, RSRP, SINR) are not included unless specifically stated. Additional testing, rebalancing, or redesign required due to coverage changes or customer-requested expansion will be billed separately.

System Changes

Any changes to scope, coverage area, antenna count, or system layout requested after design approval will require a formal change order.

Quote #005882 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 3 of 6

Hardware

Description Price Qty Ext. Price

SM64-BLC (4G

LTE)

eFemto3 Network Extender (SKU: SM64-BLC) $2,999.99 1 $2,999.99

TC-CN-N-J-1/2-

PC

N Male Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NM-12

$33.64 12 $403.68

TC-CN-N-K-1/2

-PC

N Female Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NF-12

$32.48 2 $64.96

NM50C400 Connector, N male crimp for EC400 cable $38.79 2 $77.58

EZ-400-NF-X N-FEMALE (JACK)CRIMPCONNECTOR $24.22 2 $48.44

GPS-TMG-HR-

26NCM

GPS Timing Ant, 26dB,3.3-12Vdc N-Female w/ Red Collar Mount

$330.00 1 $330.00

WM4 4" Clearance Wall Mount $49.70 1 $49.70

TC-AI698-

2700V05i360B

Wide Band indoor Omni Antenna: Frequency Rang(MHz) 698~960/1710~2700,Impedance(O) 50,VSWR =1.8/1.5,PIM<- 153dBc@2x20W; Polarization Type Vertical,Gain(dBi) 2/5dBi,Horizontal Half Power Beam-width (°) 360,Maximum Input Power(W) 50,Connector Type N-F

$49.70 3 $149.10

TC-AI698-

2700V09iB

Indoor Directional Panel Antenna, 698-2700MHz, Gain 7-8dBi, VSWR <1.8, PIM -153dBc @ 2x20W, N-Female

$62.30 1 $62.30

TC-JP-RG402-

NM/NF-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NF, PIM < - 153dBc

$37.10 1 $37.10

T1RFC-13567-

CBL ASSY, N Male To SMA Male RA; RG-58/U; with Tessco Label

$42.12 3 $126.36

TC-JP-RG402-

NM/NM-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NM, PIM < - 153dBc

$35.35 2 $70.70

LMR-400 3/8IN LOW LOSSCOAX 50 OHMS $1.90 150 $285.00

ICA12-50JPLB 1/2", Corrugated Copper, Black Jacket, Plenum-Rated, Coaxial CableBulk, $3.64 250 $910.00

TC-PCCoM-

06DI

6dB Coupler, Frequency: 698-2700MHz; Coupling value:

6±0.7dB; Insertion Loss(dB)=2.15;VSWR:=1.3;PIM(dBc)=-153 (With 2×20W); Directivity(dB)=20;Power Capacity(W) 200;Connector Type N-F

$52.50 2 $105.00

Quote #005882 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 4 of 6

Description Price Qty Ext. Price

KOP Kit of Parts:Misc Hardware, Unistrut, conduit, Zipties, Velcro, Sealant, Grommets, Weatherhead.

$200.00 1 $200.00

Subtotal: $5,919.91

Additions

Description Price Qty Ext. Price

Service - Fixed Fee

Installation Services for hardware equipment, passive devices, cabling and connections.

$3,155.00 1 $3,155.00

Service - Fixed Fee eFemto Commissioning, Testing, closeout Data collection $1,500.00 1 $1,500.00

“Services are invoiced as milestones upon completion of each service. Installation and commissioning are billed separately, as commissioning may be completed at a later stage depending on customer system and network readiness.”

$0.00

Subtotal: $4,655.00

Quote #005882 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 5 of 6

Hillsborough County Fire Station 21

Quote Information: Prepared for: Prepared by:

Quote #: 005882 Hillsborough County Source 1 Solutions

Version: 1 Delivery Date: 06/25/2026 Expiration Date: 09/30/2026

PO Box 1110 Tampa, FL 33601 PO will be accepted in lieu of signature

(813) 853-1127 CutlerR@hcfl.gov

Juan Escobedo 1 (727) 538 4114 Fax +1 (727) 683 9683 jescobedo@source1solutions.com

Quote Summary

Description Amount

Hardware $5,919.91

Additions $4,655.00

Total: $10,574.91

Taxes, shipping, handling and other fees may apply. We reserve the right to cancel orders arising from pricing or other errors.

Source 1 Solutions Hillsborough County

Signature:

Name: Juan Escobedo

Title: RF Department Manager

Date: 06/25/2026

Signature:

Name: PO will be accepted in lieu of signature

Date:

Quote #005882 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 6 of 6

Hillsborough County Fire Station 47

Quote # 005883

Version 1

This Scope of Work (SOW) is for the installation of a Verizon eFemto-based In-Building Cellular Signal Enhancement

System utilizing a Passive Distributed Antenna System (DAS). The system is intended to improve Verizon Wireless LTE indoor coverage and capacity within the building for authorized users, including voice, data, and messaging services.

The solution utilizes a Verizon-approved eFemto (small cell) unit as the signal source, which connects to the Verizon core network via the customer’s existing IP backhaul. The eFemto output is passively distributed throughout the facility using coaxial cabling, splitters, and ceiling-mounted service antennas to provide enhanced indoor coverage in designated areas.

Source 1 Technicians will install the following for each building as specified by the approved design:

Installation Scope

• Install RF coaxial cable throughout the ceiling space to support the passive DAS

• Install passive DAS service antennas mounted to ceiling tiles or pedestals as required

• Install RF splitters, couplers, and terminations per RF design

• Install and mount Verizon eFemto unit in an approved telecommunications or network closet

• Connect eFemto unit to existing customer-provided power and IP backhaul

• Label all cabling and components in accordance with industry standards

Work Environment

Work will be performed throughout the building using ladders and/or scissor lifts as required. Work areas may include, but are not limited to:

• Retail sales floor

• Office and cubicle areas

• Back-of-house and receiving/stocking areas

• Electrical and network closets

• Above accessible ceiling spaces

All cabling and antenna installation will be performed during normal business hours unless otherwise specified. The eFemto unit installation will occur in a secure IT or network room and can be completed during normal business hours.

Assumptions & Caveats for Verizon eFemto / Passive DAS Installation Quote

Scope of Coverage

This quote includes coverage only for areas identified in the approved RF design. Full-building cellular coverage is not guaranteed unless explicitly stated in the design documents. Coverage is limited to Verizon Wireless services only; no other carriers are supported.

Carrier Dependency

System performance is dependent on Verizon provisioning, approval, and activation of the eFemto unit. Any delays or limitations imposed by Verizon (including device authorization, IP configuration, or capacity restrictions) are outside the installer’s control.

Quote #005883 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 2 of 6

This design utilizes a passive DAS architecture with no active amplification or remote units. Signal levels are dependent on eFemto output power, antenna spacing, cable lengths, and building materials. Future expansion may require redesign, additional antennas, or conversion to an active or hybrid DAS.

Near-Far Effect

Due to the nature of passive DAS systems, Near-Far effects may occur if antennas are unevenly spaced or if environmental conditions change. The design assumes proper antenna isolation and balance at the time of installation; however, changes to walls, shelving, or occupancy may affect performance.

RF Propagation Assumptions

RF propagation assumptions are based on typical commercial construction materials. Materials such as metallic shelving, low-E glass, concrete, or dense mechanical spaces may reduce coverage and require additional antennas or redesign. This quote does not include RF mitigation for shielded rooms, elevator shafts, stairwells, or exterior areas unless specifically noted.

Antenna Mounting Assumptions

Service antennas are assumed to be ceiling-mounted in accessible areas with standard ceiling heights. High ceilings, hard-lid ceilings, or restricted-access areas may require additional labor and materials. No decorative concealment or architectural modifications are included unless explicitly stated.

Power and IP Backhaul

Customer will provide: • Dedicated, code-compliant electrical power for the eFemto unit

• Active IP backhaul meeting Verizon eFemto bandwidth and latency requirements

Any additional electrical work, new circuits, UPS systems, or network upgrades are excluded unless noted and will require a change order.

Pathways and Construction

Existing cable pathways and ceiling access are assumed to be available and accessible. Core drilling, fire-rated penetrations, conduit installation, or asbestos abatement are not included unless specifically stated. Any unforeseen construction obstacles will be addressed via change order.

Testing and Acceptance

This quote includes one post-installation walk test to verify basic Verizon signal presence and usability. Formal carrier certification or guaranteed performance metrics (RSSI, RSRP, SINR) are not included unless specifically stated. Additional testing, rebalancing, or redesign required due to coverage changes or customer-requested expansion will be billed separately.

System Changes

Any changes to scope, coverage area, antenna count, or system layout requested after design approval will require a formal

Quote #005883 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 3 of 6

Description Price Qty Ext. Price

SM64-BLC (4G

LTE)

eFemto3 Network Extender (SKU: SM64-BLC) $2,999.99 1 $2,999.99

TC-CN-N-J-1/2-

PC

N Male Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NM-12

$33.64 12 $403.68

TC-CN-N-K-1/2

-PC

N Female Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NF-12

$32.48 2 $64.96

NM50C400 Connector, N male crimp for EC400 cable $38.79 2 $77.58

EZ-400-NF-X N-FEMALE (JACK)CRIMPCONNECTOR $24.22 2 $48.44

GPS-TMG-HR-

26NCM

GPS Timing Ant, 26dB,3.3-12Vdc N-Female w/ Red Collar Mount

$330.00 1 $330.00

WM4 4" Clearance Wall Mount $49.70 1 $49.70

TC-AI698-

2700V05i360B

Wide Band indoor Omni Antenna: Frequency Rang(MHz) 698~960/1710~2700,Impedance(O) 50,VSWR =1.8/1.5,PIM<- 153dBc@2x20W; Polarization Type Vertical,Gain(dBi) 2/5dBi,Horizontal Half Power Beam-width (°) 360,Maximum Input Power(W) 50,Connector Type N-F

$49.70 3 $149.10

TC-AI698-

2700V09iB

Indoor Directional Panel Antenna, 698-2700MHz, Gain 7-8dBi, VSWR <1.8, PIM -153dBc @ 2x20W, N-Female

$62.30 1 $62.30

TC-JP-RG402-

NM/NF-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NF, PIM < - 153dBc

$37.10 1 $37.10

T1RFC-13567-

CBL ASSY, N Male To SMA Male RA; RG-58/U; with Tessco Label

$42.12 3 $126.36

TC-JP-RG402-

NM/NM-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NM, PIM < - 153dBc

$35.35 2 $70.70

LMR-400 3/8IN LOW LOSSCOAX 50 OHMS $1.90 150 $285.00

ICA12-50JPLB 1/2", Corrugated Copper, Black Jacket, Plenum-Rated, Coaxial CableBulk, $3.64 250 $910.00

TC-PCCoM-

06DI

6dB Coupler, Frequency: 698-2700MHz; Coupling value:

6±0.7dB; Insertion Loss(dB)=2.15;VSWR:=1.3;PIM(dBc)=-153 (With 2×20W); Directivity(dB)=20;Power Capacity(W) 200;Connector Type N-F

$52.50 2 $105.00

Quote #005883 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 4 of 6

Description Price Qty Ext. Price

KOP Kit of Parts:Misc Hardware, Unistrut, conduit, Zipties, Velcro, Sealant, Grommets, Weatherhead.

$200.00 1 $200.00

Subtotal: $5,919.91

Additions

Description Price Qty Ext. Price

Service - Fixed Fee

Installation Services for hardware equipment, passive devices, cabling and connections.

$3,120.00 1 $3,120.00

Service - Fixed Fee eFemto Commissioning, Testing, closeout Data collection $1,500.00 1 $1,500.00

“Services are invoiced as milestones upon completion of each service. Installation and commissioning are billed separately, as commissioning may be completed at a later stage depending on customer system and network readiness.”

$0.00

Subtotal: $4,620.00

Quote #005883 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 5 of 6

Hillsborough County Fire Station 47

Quote Information: Prepared for: Prepared by:

Quote #: 005883 Hillsborough County Source 1 Solutions

Version: 1 Delivery Date: 06/25/2026 Expiration Date: 09/30/2026

PO Box 1110 Tampa, FL 33601 PO will be accepted in lieu of signature

(813) 853-1127 CutlerR@hcfl.gov

Juan Escobedo 1 (727) 538 4114 Fax +1 (727) 683 9683 jescobedo@source1solutions.com

Quote Summary

Description Amount

Hardware $5,919.91

Additions $4,620.00

Total: $10,539.91

Taxes, shipping, handling and other fees may apply. We reserve the right to cancel orders arising from pricing or other errors.

Source 1 Solutions Hillsborough County

Signature:

Name: Juan Escobedo

Title: RF Department Manager

Date: 06/25/2026

Signature:

Name: PO will be accepted in lieu of signature

Quote #005883 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 6 of 6

Hillsborough County Fire Station 48

Quote # 005884

Version 1

This Scope of Work (SOW) is for the installation of a Verizon eFemto-based In-Building Cellular Signal Enhancement

System utilizing a Passive Distributed Antenna System (DAS). The system is intended to improve Verizon Wireless LTE indoor coverage and capacity within the building for authorized users, including voice, data, and messaging services.

The solution utilizes a Verizon-approved eFemto (small cell) unit as the signal source, which connects to the Verizon core network via the customer’s existing IP backhaul. The eFemto output is passively distributed throughout the facility using coaxial cabling, splitters, and ceiling-mounted service antennas to provide enhanced indoor coverage in designated areas.

Source 1 Technicians will install the following for each building as specified by the approved design:

Installation Scope

• Install RF coaxial cable throughout the ceiling space to support the passive DAS

• Install passive DAS service antennas mounted to ceiling tiles or pedestals as required

• Install RF splitters, couplers, and terminations per RF design

• Install and mount Verizon eFemto unit in an approved telecommunications or network closet

• Connect eFemto unit to existing customer-provided power and IP backhaul

• Label all cabling and components in accordance with industry standards

Work Environment

Work will be performed throughout the building using ladders and/or scissor lifts as required. Work areas may include, but are not limited to:

• Retail sales floor

• Office and cubicle areas

• Back-of-house and receiving/stocking areas

• Electrical and network closets

• Above accessible ceiling spaces

All cabling and antenna installation will be performed during normal business hours unless otherwise specified. The eFemto unit installation will occur in a secure IT or network room and can be completed during normal business hours.

Assumptions & Caveats for Verizon eFemto / Passive DAS Installation Quote

Scope of Coverage

This quote includes coverage only for areas identified in the approved RF design. Full-building cellular coverage is not guaranteed unless explicitly stated in the design documents. Coverage is limited to Verizon Wireless services only; no other carriers are supported.

Carrier Dependency

System performance is dependent on Verizon provisioning, approval, and activation of the eFemto unit. Any delays or limitations

Quote #005884 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 2 of 6 imposed by Verizon (including device authorization, IP configuration, or capacity restrictions) are outside the installer’s control.

Passive DAS Limitations

This design utilizes a passive DAS architecture with no active amplification or remote units. Signal levels are dependent on eFemto output power, antenna spacing, cable lengths, and building materials. Future expansion may require redesign, additional antennas, or conversion to an active or hybrid DAS.

Near-Far Effect

Due to the nature of passive DAS systems, Near-Far effects may occur if antennas are unevenly spaced or if environmental conditions change. The design assumes proper antenna isolation and balance at the time of installation; however, changes to walls, shelving, or occupancy may affect performance.

RF Propagation Assumptions

RF propagation assumptions are based on typical commercial construction materials. Materials such as metallic shelving, low-E glass, concrete, or dense mechanical spaces may reduce coverage and require additional antennas or redesign. This quote does not include RF mitigation for shielded rooms, elevator shafts, stairwells, or exterior areas unless specifically noted.

Antenna Mounting Assumptions

Service antennas are assumed to be ceiling-mounted in accessible areas with standard ceiling heights. High ceilings, hard-lid ceilings, or restricted-access areas may require additional labor and materials. No decorative concealment or architectural modifications are included unless explicitly stated.

Power and IP Backhaul

Customer will provide: • Dedicated, code-compliant electrical power for the eFemto unit

• Active IP backhaul meeting Verizon eFemto bandwidth and latency requirements

Any additional electrical work, new circuits, UPS systems, or network upgrades are excluded unless noted and will require a change order.

Pathways and Construction

Existing cable pathways and ceiling access are assumed to be available and accessible. Core drilling, fire-rated penetrations, conduit installation, or asbestos abatement are not included unless specifically stated. Any unforeseen construction obstacles will be addressed via change order.

Testing and Acceptance

This quote includes one post-installation walk test to verify basic Verizon signal presence and usability. Formal carrier certification or guaranteed performance metrics (RSSI, RSRP, SINR) are not included unless specifically stated. Additional testing, rebalancing, or redesign required due to coverage changes or customer-requested expansion will be billed separately.

System Changes

Any changes to scope, coverage area, antenna count, or system layout requested after design approval will require a formal

Quote #005884 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 3 of 6

Hardware

Description Price Qty Ext. Price

SM64-BLC (4G

LTE)

eFemto3 Network Extender (SKU: SM64-BLC) $2,999.99 1 $2,999.99

TC-CN-N-J-1/2-

PC

N Male Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NM-12

$33.64 12 $403.68

TC-CN-N-K-1/2

-PC

N Female Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NF-12

$32.48 2 $64.96

NM50C400 Connector, N male crimp for EC400 cable $38.79 2 $77.58

EZ-400-NF-X N-FEMALE (JACK)CRIMPCONNECTOR $24.22 2 $48.44

GPS-TMG-HR-

26NCM

GPS Timing Ant, 26dB,3.3-12Vdc N-Female w/ Red Collar Mount

$330.00 1 $330.00

WM4 4" Clearance Wall Mount $49.70 1 $49.70

TC-AI698-

2700V05i360B

Wide Band indoor Omni Antenna: Frequency Rang(MHz) 698~960/1710~2700,Impedance(O) 50,VSWR =1.8/1.5,PIM<- 153dBc@2x20W; Polarization Type Vertical,Gain(dBi) 2/5dBi,Horizontal Half Power Beam-width (°) 360,Maximum Input Power(W) 50,Connector Type N-F

$49.70 3 $149.10

TC-AI698-

2700V09iB

Indoor Directional Panel Antenna, 698-2700MHz, Gain 7-8dBi, VSWR <1.8, PIM -153dBc @ 2x20W, N-Female

$62.30 1 $62.30

TC-JP-RG402-

NM/NF-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NF, PIM < - 153dBc

$37.10 1 $37.10

T1RFC-13567-

CBL ASSY, N Male To SMA Male RA; RG-58/U; with Tessco Label

$42.12 3 $126.36

TC-JP-RG402-

NM/NM-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NM, PIM < - 153dBc

$35.35 2 $70.70

LMR-400 3/8IN LOW LOSSCOAX 50 OHMS $1.90 150 $285.00

ICA12-50JPLB 1/2", Corrugated Copper, Black Jacket, Plenum-Rated, Coaxial CableBulk, $3.64 250 $910.00

Quote #005884 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 4 of 6

Description Price Qty Ext. Price

TC-PCCoM-

06DI

6dB Coupler, Frequency: 698-2700MHz; Coupling value:

6±0.7dB; Insertion Loss(dB)=2.15;VSWR:=1.3;PIM(dBc)=-153 (With 2×20W); Directivity(dB)=20;Power Capacity(W) 200;Connector Type N-F

$52.50 2 $105.00

KOP Kit of Parts:Misc Hardware, Unistrut, conduit, Zipties, Velcro, Sealant, Grommets, Weatherhead.

$200.00 1 $200.00

Subtotal: $5,919.91

Additions

Description Price Qty Ext. Price

Service - Fixed Fee

Installation Services for hardware equipment, passive devices, cabling and connections.

$3,315.00 1 $3,315.00

Service - Fixed Fee eFemto Commissioning, Testing, closeout Data collection $1,560.00 1 $1,560.00

“Services are invoiced as milestones upon completion of each service. Installation and commissioning are billed separately, as commissioning may be completed at a later stage depending on customer system and network readiness.”

$0.00

Subtotal: $4,875.00

Quote #005884 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 5 of 6

Hillsborough County Fire Station 48

Quote Information: Prepared for: Prepared by:

Quote #: 005884 Hillsborough County Source 1 Solutions

Version: 1 Delivery Date: 06/25/2026 Expiration Date: 09/30/2026

PO Box 1110 Tampa, FL 33601 PO will be accepted in lieu of signature

(813) 853-1127 CutlerR@hcfl.gov

Juan Escobedo 1 (727) 538 4114 Fax +1 (727) 683 9683 jescobedo@source1solutions.com

Quote Summary

Description Amount

Hardware $5,919.91

Additions $4,875.00

Total: $10,794.91

Taxes, shipping, handling and other fees may apply. We reserve the right to cancel orders arising from pricing or other errors.

Source 1 Solutions Hillsborough County

Signature:

Name: Juan Escobedo

Title: RF Department Manager

Date: 06/25/2026

Signature:

Name: PO will be accepted in lieu of signature

Quote #005884 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 6 of 6

Fire Rescue Warehouse HC - eFemto

Quote # 004959

Version 1

This Scope of Work (SOW) is for the installation of a Verizon eFemto-based In-Building Cellular Signal Enhancement

System utilizing a Passive Distributed Antenna System (DAS). The system is intended to improve Verizon Wireless LTE indoor coverage and capacity within the building for authorized users, including voice, data, and messaging services.

The solution utilizes a Verizon-approved eFemto (small cell) unit as the signal source, which connects to the Verizon core network via the customer’s existing IP backhaul. The eFemto output is passively distributed throughout the facility using coaxial cabling, splitters, and ceiling-mounted service antennas to provide enhanced indoor coverage in designated areas.

Source 1 Technicians will install the following for each building as specified by the approved design:

Installation Scope

• Install RF coaxial cable throughout the ceiling space to support the passive DAS

• Install passive DAS service antennas mounted to ceiling tiles or pedestals as required

• Install RF splitters, couplers, and terminations per RF design

• Install and mount Verizon eFemto unit in an approved telecommunications or network closet

• Connect eFemto unit to existing customer-provided power and IP backhaul

• Label all cabling and components in accordance with industry standards

Work Environment

Work will be performed throughout the building using ladders and/or scissor lifts as required. Work areas may include, but are not limited to:

• Retail sales floor

• Office and cubicle areas

• Back-of-house and receiving/stocking areas

• Electrical and network closets

• Above accessible ceiling spaces

All cabling and antenna installation will be performed during normal business hours unless otherwise specified. The eFemto unit installation will occur in a secure IT or network room and can be completed during normal business hours.

Assumptions & Caveats for Verizon eFemto / Passive DAS Installation Quote

Scope of Coverage

This quote includes coverage only for areas identified in the approved RF design. Full-building cellular coverage is not guaranteed unless explicitly stated in the design documents. Coverage is limited to Verizon Wireless services only; no other carriers are supported.

Carrier Dependency

System performance is dependent on Verizon provisioning, approval, and activation of the eFemto unit. Any delays or limitations imposed by Verizon (including device authorization, IP configuration, or capacity restrictions) are outside the installer’s control.

Quote #004959 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 2 of 6

This design utilizes a passive DAS architecture with no active amplification or remote units. Signal levels are dependent on eFemto output power, antenna spacing, cable lengths, and building materials. Future expansion may require redesign, additional antennas, or conversion to an active or hybrid DAS.

Near-Far Effect

Due to the nature of passive DAS systems, Near-Far effects may occur if antennas are unevenly spaced or if environmental conditions change. The design assumes proper antenna isolation and balance at the time of installation; however, changes to walls, shelving, or occupancy may affect performance.

RF Propagation Assumptions

RF propagation assumptions are based on typical commercial construction materials. Materials such as metallic shelving, low-E glass, concrete, or dense mechanical spaces may reduce coverage and require additional antennas or redesign. This quote does not include RF mitigation for shielded rooms, elevator shafts, stairwells, or exterior areas unless specifically noted.

Antenna Mounting Assumptions

Service antennas are assumed to be ceiling-mounted in accessible areas with standard ceiling heights. High ceilings, hard-lid ceilings, or restricted-access areas may require additional labor and materials. No decorative concealment or architectural modifications are included unless explicitly stated.

Power and IP Backhaul

Customer will provide: • Dedicated, code-compliant electrical power for the eFemto unit

• Active IP backhaul meeting Verizon eFemto bandwidth and latency requirements

Any additional electrical work, new circuits, UPS systems, or network upgrades are excluded unless noted and will require a change order.

Pathways and Construction

Existing cable pathways and ceiling access are assumed to be available and accessible. Core drilling, fire-rated penetrations, conduit installation, or asbestos abatement are not included unless specifically stated. Any unforeseen construction obstacles will be addressed via change order.

Testing and Acceptance

This quote includes one post-installation walk test to verify basic Verizon signal presence and usability. Formal carrier certification or guaranteed performance metrics (RSSI, RSRP, SINR) are not included unless specifically stated. Additional testing, rebalancing, or redesign required due to coverage changes or customer-requested expansion will be billed separately.

System Changes

Any changes to scope, coverage area, antenna count, or system layout requested after design approval will require a formal

Quote #004959 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 3 of 6

Hardware & Materials

Description Price Qty Ext. Price

SM64-BLC (4G

LTE)

eFemto3 Network Extender (SKU: SM64-BLC) $2,999.99 1 $2,999.99

GPS-TMG-HR-

26NCM

GPS Timing Ant, 26dB,3.3-12Vdc N-Female w/ Red Collar Mount

$330.00 1 $330.00

WM4 4" Clearance Wall Mount $49.70 1 $49.70

TC-AI698-

2700V05i360B

Wide Band indoor Omni Antenna: Frequency Rang(MHz) 698~960/1710~2700,Impedance(O) 50,VSWR =1.8/1.5,PIM<- 153dBc@2x20W; Polarization Type Vertical,Gain(dBi) 2/5dBi,Horizontal Half Power Beam-width (°) 360,Maximum Input Power(W) 50,Connector Type N-F

$49.70 2 $99.40

T1RFC-13567-

CBL ASSY, N Male To SMA Male RA; RG-58/U; with Tessco Label

$42.12 2 $84.24

TC-JP-RG402-

NM/NF-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NF, PIM < - 153dBc

$37.10 1 $37.10

TC-JP-RG402-

NM/NM-3 (5G)

RG402(small size) Blue cable, 3 feet Jumper NM to NM, PIM < - 153dBc

$35.35 1 $35.35

LMR-400 3/8IN LOW LOSSCOAX 50 OHMS $1.90 200 $380.00

ICA12-50JPLB 1/2", Corrugated Copper, Black Jacket, Plenum-Rated, Coaxial CableBulk, $3.64 250 $910.00

P2RFC-2068-

SMA Male to N Male;TFT-402-LF cable, plenum and PIM rated; $46.50 3 $139.50

NM50C400 Connector, N male crimp for EC400 cable $38.79 2 $77.58

EZ-400-NF-X N-FEMALE (JACK)CRIMPCONNECTOR $24.22 2 $48.44

TC-CN-N-J-1/2-

PC

N Male Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NM-12

$33.64 4 $134.56

TC-CN-N-K-1/2

-PC

N Female Straight Connector for 1/2" Annular Plenum cable, LOW PIM < -161dBc, DC-6GHz, 50ohm; Equivalent to JMA Wireless UPL-NF-12

$32.48 2 $64.96

Subtotal: $5,390.82

Quote #004959 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 4 of 6

Services

Description Price Qty Ext. Price

LIFT RENTAL LIFT RENTAL $1,250.00 1 $1,250.00

Service - Fixed Fee

Installation Services for hardware equipment, passive devices, cabling and connections.

$4,680.00 1 $4,680.00

Service - Fixed Fee eFemto Commissioning, Testing, closeout Data collection $1,500.00 1 $1,500.00

“Services are invoiced as milestones upon completion of each service. Installation and commissioning are billed separately, as commissioning may be completed at a later stage depending on customer system and network readiness.”

$0.00

Subtotal: $7,430.00

Quote #004959 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 5 of 6

Fire Rescue Warehouse HC - eFemto

Quote Information: Prepared for: Prepared by:

Quote #: 004959 Hillsborough County Source 1 Solutions

Version: 1 Delivery Date: 06/25/2026 Expiration Date: 09/30/2026

PO Box 1110 Tampa, FL 33601 PO will be accepted in lieu of signature

(813) 853-1127 CutlerR@hcfl.gov

Juan Escobedo 1 (727) 538 4114 Fax +1 (727) 683 9683 jescobedo@source1solutions.com

Quote Summary

Description Amount

Hardware & Materials $5,390.82

Services $7,430.00

Total: $12,820.82

Taxes, shipping, handling and other fees may apply. We reserve the right to cancel orders arising from pricing or other errors.

Source 1 Solutions Hillsborough County

Signature:

Name: Juan Escobedo

Title: RF Department Manager

Date: 06/25/2026

Signature:

Name: PO will be accepted in lieu of signature

Quote #004959 v1 16331 Bay Vista Dr Clearwater, FL 33760 Page: 6 of 6

Quote - FS21
Quote - FS47
Quote - FS48
Quote - WH