2-Pine Grove Twp Ph 3 Plan Set - Issued for Construction.pdf
PDF 6 MB Posted
- Attached to
- Schuylkill County, PA - Pine Grove Township, CDBG Building ADA Improvement - Phase III (0326-609043.26)
- Solicitation number
- US.258250
- Issued by
- Somerset County, Pennsylvania
About this file
This file is a plan set issued for construction for the Pine Grove Township Building ADA Improvement Project – Phase III, located at 175 Oak Grove Road, Pine Grove, Pennsylvania 17963, involving Schuylkill County and Pine Grove Township. The project encompasses ADA improvements to the municipal building's bathroom facilities and transaction counter, along with ADA-compliant sidewalk installation extending from the existing sidewalk to the mailbox. The work includes demolition and renovation of toilet areas, creation of new accessible unisex facilities, lobby modifications, and concrete sidewalk construction with proper drainage and grading. The total building area is 3,884 square feet. Sealed bids are due online via the PennBid Program by 9:00 AM on Wednesday, October 28, 2026, with public opening and tentative award on November 11, 2026. A non-mandatory pre-bid meeting is scheduled for Tuesday, October 20, 2026, at 9:30 AM at the Pine Grove Township Municipal building. The entire project will be awarded to a single contractor, and all bidding documents are available at no cost through PennBid.
The successful bidder must provide a bid bond in the amount of 10 percent of the total bid and will be required to furnish performance and payment bonds each equal to 100 percent of the contract price with an acceptable corporate surety. The project is funded through CDBG (Community Development Block Grant) funds. Contractors must comply with applicable codes including the 2018 International Building Code, 2017 ANSI A117.1, and 2010 ADA standards. The project is classified as Use Group B with Construction Type VB. Contractors are responsible for all utility coordination, erosion and sedimentation control measures, subsurface verification, and compliance with Pennsylvania Act 287 regarding underground utilities. Temporary and permanent stabilization measures, seeding specifications, and proper fill placement are detailed in the erosion and sediment control notes and specifications included in the plan set.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Room name
Occupancy Type
Occupancy Load
Occupancy Type
Occupancy Load Occ.
Occupancy Ratio
Area
S03BW-20101
XX
P-1
CONTROL LINE GRID LINE
ROOM TAG
CALLOUT
DOOR TAG WINDOW TAG PARTITION
TYPE
LENGTH AND
DIRECTION OF
TRAVEL (CODE)
SPACE OCCUPANCY
TYPE AND LOAD
(CODE)
DIRECTIONAL
ARROW
CENTERLINE PLUMBING
FIXTURE TAG
REVISION
CLOUD
HEARING
IMPAIRED
ACCESSIBLE
A-102
ELEVATION
CALLOUT
NOTE: TEXT IN SYMBOLS MAY
DIFFER FROM EXAMPLES SHOWN
XX'
XX'
SPOT ELEVATION
(ELEVATION OR
SECTION VIEW)
SPOT ELEVATION
(PLAN VIEW)
LEVEL
DATUM
SECTION CEILING
ELEVATION
(PLAN VIEW)
Name
Elevation
MATERIAL
@ 1'-0"
A101
SIM
P L
A N
N O
R T
H
TRUE NORTH
PLAN NORTH
A101
SIM
EXISTING
LOBBY
EXISTING OPEN
OFFICE
OFFICE
EXISTING
STORAGE
EXISTING
KITCHEN
NEW
ACCESSIBLE
UNISEX TOILET
EXISTING
JANITOR
<E> MEETING
ROOM
STAIRWELLCORR.
OFFICE
CORR.
OFFICE
OFFICE
NEW ADA
TOILET
PLANA-102
EXISTING
(UNISEX) TOILET
A-101
A-102
2 DEMO
PLAN
NEW
LOBBY
PLAN
A-102
3 CEILING
PLAN
EXISTING
CORRIDOR
Date
Drawn By
Checked By
Project Number
GREENFIELD ARCHITECTS, LTD.
These plans are copyrighted and are subject to copyright protection as an "architectural work" under Section 102 of the Copyright Act, 17 U.S.O. as amended December 1990 and known as Architectural Copyright Protection Act of 1990. The protection includes but is not limited to the overall form as well as the arrangement and composition of spaces and elements of design. Under such protection, anauthorized use of these plans, or work represented, can legally result in the penalties provided.
Any reproduction of this document in part or whole without the express written permission of Greenfield Architects, Ltd. is strictly prohibited.
ABCDEFGH
ABCDEFGH
/3
/2
:2
:3
A
M
TM
MJD
05/29/2026
26015
CDBG TOWNSHIP
BUILDING
ADA IMPROVEMENT
PROJECT - PHASE 3
PINE GROVE TOWNSHIP
175 OAK GROVE ROAD
PINE GROVE, PA 17963
A-001
COVER AND DATA SHEET -
PHASE 3
PROJECT NAME/ LOCATION
CDBG TOWNSHIP BUILDING
ADA IMPROVEMENT PROJECT - PHASE 1
PINE GROVE TOWNSHIP
175 OAK GROVE ROAD
PINE GROVE, PA 17693
ARCHITECT'S PROJECT NO.: 23020
APPLICABLE CODES
2018 IBC
2017 ANSI A117.1
2010 ADA
USE GROUP CLASSIFICATION
USE GROUP: B
CONSTRUCTION CLASSIFICATION
CONSTRUCTION TYPE: VB
BUILDING HEIGHT, STORIES, AND AREA
40' PERMITTED > 28' ACTUAL = OK
2 STORIES PERMITTED = 2 STORIES ACTURAL = OK
BUILDING AREA
BASEMENT FLOOR 1,726 SF
FIRST FLOOR 2,158 SF
TOTAL BUILDING 3,884 SF
9,000 SF PERMITTED > 2,158 SF ACTUAL = OK
BENESCH
400 One Norwegian Plaza Pottsville, PA 17901 Phone: 570-622-4055
Ryan Fasnacht, P.E., Senior Project Manager / Principal Associate rfasnacht@benesch.com Direct Phone: 570-624-4275 Mobile Phone: 570-294-7778 Office Phone: 570-622-4055
James Tohill, P.E.
Project Manager jtohill@benesch.com Direct Phone: 570-624-4282 Office Phone: 570-622-4055
OWNER'S REPRESENTATIVE
DORMAKABA AMERICAS
Eastern PA / Southern NJ / Delaware / Eastern Shore MD Phone: 267-377-4174 Fax: 866-232-0509
Benjamin Gorton, DAHC, DHT, DHC, CFDAI, QFDI, QDOC / CSI
Architectural Consulting Representative / Architectural Services / National Accounts benjamin.gorton@dormakaba.com www.dormakaba.us
HARDWARE CONSULTANT
GREENFIELD ARCHITECTS, LTD.
1853 William Penn Way Lancaster, PA 17601 Phone: 717-293-4475 Fax: 717-293-4499
Thomas Marcinkoski, AIA, Senior Project Architect tmarcinkoski@high.net Phone: 717-390-4614
ARCHITECT
DRAWING INDEX
LOCATION MAP
PROJECT DATA PROJECT DIRECTORYABBREVIATIONS
SYMBOL LEGEND
ACC
ACT
AFF
AHU
ALUM
AS
BF
BLK
BLK'G
BS
BLD'G
BOT
CIP
CLG
COL
CJ
CO
CONC
CMU
CONT
CPT
CPT TL
CT
DIAG
DIA
DO
DS
DF
DR
E
EA
EIFS
ES
ELEC
ELEV
EP
EQ
EQPM
EXIST
EXP
ACCESSIBLE
ACOUSTICAL LAY-IN CEILING
ABOVE FINISHED FLOOR
AIR HANDLING UNIT
ALUMINUM
ACTUAL SIZE
BROOM FINISH
BLOCK
BLOCKING
BOTH SIDES
BUILDING
BOTTOM
CAST-IN-PLACE
CEILING
COLUMN
CONTROL JOINT
CASED OPENING
CONCRETE
CONCRETE MASONRY UNIT
CONTINUOUS
CARPET
CARPET TILE
CERAMIC TILE
DIAGONAL
DIAMETER
DITTO
DOWNSPOUT
DRINKING FOUNTAIN
DOOR
EPOXY
EACH
EXTERIOR INSULATION & FINISH SYSTEM
EACH SIDE
ELECTRICAL
ELEVATION
EPOXY PAINT
EQUAL
EQUIPMENT
EXISTING
EXPANSION
EX STL
ET
EXT
EXP JT
EWC
FG
FTG
FT
FLG
FD
FE
FRP
GA
GALV
GM
GS
GB
GB LL
HCW
HDW
HVAC
HT
HM
HOR
IAL
ID
IGHM
IHM
INSUL
INT
IPL
IPFGM
ITGL
IWGL
IWP
JT
KD
LAM
LAV
EXPOSED STEEL
EPOXY TERRAZZO
EXTERIOR
EXPANSION JOINT
ELECTRIC WATER COOLER
FIBERGLASS
FOOTING
FEET
FLASHING
FLOOR DRAIN
FIRE EXTINGUISHER
FIBERGLASS REINFORCED PANEL
GAUGE
GALVANIZED
GALVANIZED METAL
GALVANIZED STEEL
GYPSUM BOARD
GYPSUM BOARD - LEAD LINED
HOLLOW CORE WOOD
HARDWARE
HEATING, VENTILATING AND AIR CONDITIONING
HEIGHT
HOLLOW METAL
HORIZONTAL
INSULATED ACRYLIC LITE
INSIDE DIAMETER
INSULATED GALVANIZED HOLLOW METAL
INSULATED HOLLOW METAL
INSULATED/ INSULATION
INTERIOR
INSULATED PLYWOOD LAMINATE
INSULATED PREFINISHED GALVANIZED METAL
INSULATED TEMPERED GLASS
INSULATED WIRE GLASS
INSULATED WALL PANEL
JOINT
KNOCKED DOWN
LAMINATE
LAVATORY
LVL
MAN
MCW
MFR
MO
MOT
MLDG
MATL
MAX
MECH
MT
MTL
MLP
MISC
MR
NA
NIC
NTS
NO
OD
OPP
OH
PCT
PC
PF
PFB
PMF
PLYWD
PIP
PP
PCLN
PT
PTD
QT
RAF
REINF
RFM
RO
RM
RTU
LEVEL
MANUAL OPERATION
METAL CLAD WOOD
MANUFACTURER
MASONRY OPENING
MOTOR OPERATOR
MOULDING
MATERIAL
MAXIMUM
MECHANICAL
MARBLE THRESHOLD
METAL
METAL LINER PANEL
MISCELLANEOUS
MOISTURE RESISTANT
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
NUMBER
OUTSIDE DIAMETER
OPPOSITE
OPPOSITE HAND
PERCENT
PRECAST
PREFINISHED
PREFABRICATED
PRE-MOLDED FILLER
PLYWOOD
POURED IN PLACE
PRIME PAINTED
PORCELAIN TILE
PRESSURE TREATED
PAINTED
QUARRY TILE
RAISED ACCESS FLOOR
REINFORCING
RECESSED FLOOR MAT
ROUGH OPENING
ROOM
ROOF TOP UNIT
SC
SG
SHT
SEC
SIM
SPEC
SCW
SQ
SPF
SS
STL
SUSP
SF
TB
TBD
TGL
THML
TFF
THK
T&G
TOC
TOM
TOS
TD
T
TT
UL
VB
VCT
VERT
VLC
VS
VTR
VWC
WGL
WWF
WIN
W/ W/O
WD
SEALED CONCRETE
STEEL GRATE
SHEET
SECTION
SIMILAR
SPECIFICATION
SOLID CORE WOOD
SQUARE
STAIN (PREFINISHED)
STAINLESS STEEL
STEEL
SUSPENDED
SQUARE FEET
TERRAZZO BASE
TO BE DETERMINED
TEMPERED GLASS
THERMAL BREAK
TOP OF FINISHED FLOOR
THICK
TONGUE AND GROOVE
TOP OF CONCRETE
TOP OF MASONRY
TOP OF STEEL
TRENCH DRAIN
TROWEL
TERAZZO TILE
UNDERWRITERS LAB.
VINYL BASE
VINYL COMPOSITION TILE
VERTICAL
VINYL LAY-IN CEILING
VINYL SHEET
VENT THROUGH ROOF
VINYL WALL COVERING
WIRE GLASS LITE
WELDED FIRE FABRIC
WINDOW
WITH
WITHOUT
WOOD
ARCHITECT'S PROJECT NUMBER: 26015
ISSUE DATE: 17 SEPTEMBER 2026
DRAWING
NO. TITLE
DATE
RELEASED
RELEASE
GENERAL
DRAWING
NO. TITLE
DATE
RELEASED
RELEASE
CIVIL
DRAWING
NO. TITLE
DATE
RELEASED
RELEASE
STRUCTURAL
DRAWING
NO. TITLE
DATE
RELEASED
RELEASE
ARCHITECTURAL
CDBG TOWNSHIP BUILDING ADA
IMPROVEMENT PROJECT - PHASE 3
PINE GROVE TOWNSHIP
175 OAK GROVE ROAD, PINE GROVE, PA 17963
DRAWING
NO. TITLE
DATE
RELEASED
RELEASE
MECHANICAL / ELECTRICAL
EXISTING
BUILDING SITE
NOT APPLICABLE IN PHASE 3
PINE GROVE TOWNSHIP
OWNER
SCHUYLKILL COUNTY
401 N 2nd Street Pottsville, PA 17901
Ron Zimmerman Grant Manager rzimmerman@schuylkillcounty.pa.gov Office Phone: 570-628-1208
Cheryl Fuss Assistant Coordinator / Compliance Officer cfuss@schuylkillcounty.pa.gov Office Phone: 570-628-1206
GRANT ADMINISTRATOR
MEP0.0 MECHANICAL, ELECTRICAL & PLUMBING
INFORMATION SHEET
05/29/2026 ISSUED FOR
CONSTRUCTION
MEP1.0 MECHANICAL, ELECTRICAL & PLUMBING FLOOR
PLANS
05/29/2026 ISSUED FOR
CONSTRUCTION
MEP2.0 MECHANICAL, ELECTRICAL & PLUMBING
SPECIFICATIONS
05/29/2026 ISSUED FOR
CONSTRUCTION
A-101 NEW LOBBY TRANSACTION COUNTER FLOOR PLAN
- PHASE 3
09/17/2026 ISSUED FOR
CONSTRUCTION
A-102 TOILET PLANS, NOTES & INTERIOR ELEVAIONS -
PHASE 3
09/17/2026 ISSUED FOR
CONSTRUCTION
3/16" = 1'-0"1
EXISTING FIRST FLOOR PLAN - PHASE 3
A-001 COVER AND DATA SHEET - PHASE 3 09/17/2026 ISSUED FOR
CONSTRUCTION
No. Description Date
1 ISSUED FOR CONSTRUCTION 09-17-2026
C-101 GENERAL NOTES 09/17/2026 ISSUED FOR
CONSTRUCTION
C-102 SIDEWALK DETAILS 09/17/2026 ISSUED FOR
CONSTRUCTION
C-103 E&S NOTES 09/17/2026 ISSUED FOR
CONSTRUCTION
C-104 E&S DETAILS 09/17/2026 ISSUED FOR
CONSTRUCTION
E
N
N S Y L V
A
N
I A
C O
M
M O
NW EALT
H
O
F
REGISTERED
PROFESSIONAL
ENGINEER
PE077612
JAMES STEVEN TOHILL
Sheet No.:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Pine Grove Township, Schuylkill County, Pennsylvania
ADA IMPROVEMENT PROJECT - PHASE III
CDBG TOWNSHIP BUILDING
PINE GROVE TOWNSHIP
9/17/2026 0326-609043.26
$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$
CONC M
ON
BM 101
CONC M
ON
SAN C
O
I PIN
(FND)
GV
SAN C
O
MIN
ICIP
AL BLDG
PINE GROVE TWP
PARKINGHANDICAP
PARKINGHANDICAP
PARKINGHANDICAP
PILL
AR
PILL
AR
BM "A
ELEV=605
.09'LIGHT POLEMAG SP
IKE SET IN
BM "A
0-S4
W/U
G
PPL
POST
LIGHT
POST
LIGHT
LIGHT
FLOOD
BOX
DROP
ELEV=608
.44
FINI
SHED FL
OOR
ELEV=608
.42'
FINI
SHED FL
OOR
ELEV=599
.66'
FINI
SHED FL
OOR
ELEV=599
.64'FINI
SHED FL
OOR
CONC W
ALK
CONC WALK
TANK
PROPANE
TANK
PROPANE
WALL
TIMBER
BARRIER
MUNICI
PAL BLDG
PINE GROVE TWP
LOT
BIT
PARKING
UNIT
AC
UNIT
HEAT/AC
GENERATOR
CP NO 1
WALK
PAVER
FLAG POLE
CP NO 2
CP NO 3
GENERAL NOTES
AND (3) TO AVOID ALL UNNECESSARY CONFLICTS THEREWITH.
OWNERS INDEPENDENTLY, (2) TO DETERMINE THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION OR DEMOLITION
CONTRACTOR IS RESPONSIBLE AT ITS SOLE COST AND EXPENSE AND WITHOUT RELIANCE ON THESE PLANS: (1) TO CONTACT ALL UTILITY
UNDERGROUND UTILITIES IS FOR GENERAL INFORMATION AND GUIDANCE ONLY, AND IS NOT GUARANTEED TO BE COMPLETE OR ACCURATE.
NOTE: INFORMATION ON THESE PLANS CONCERNING THE CONDITIONS, DIMENSIONS, DEPTH, SIZE, LOCATION OR ANY OTHER FEATURE OF
SURFACE INFORMATION IS INDICATED ON THE DRAWINGS.
ALL UNDERGROUND INSTALLATION OR STRUCTURES ARE SHOWN ON THE PLANS. NO FIELD EXCAVATION HAS BEEN PERFORMED. AVAILABLE
ACCURACY OF THE LOCATION OF THE PRESENT UNDERGROUND UTILITY INSTALLATION OR STRUCTURES SHOWN ON THE PLANS, OR THAT
BENESCH FROM THE UTILITIES LISTED ABOVE. BENESCH DOES NOT GUARANTEE, REPRESENT, WARRANT OR ASSURE EITHER THE
WARNING! EXISTING UTILITIES, AS SHOWN ON THESE DRAWINGS, ARE IN ACCORDANCE WITH INFORMATION THAT HAS BEEN PROVIDED TO
AARON.RITTENBAUGH@OUTLOOK.COM
ATTN: AARON RITTENBAUGH
PINE GROVE, PA 17963
235 SUDEBURG RD
PINE GROVE JOINT TREATMENT AUTHORITY
DLHAUPT@PPLWEB.COM
ATTN: DOUG HAUPT
PAXINOS, PA 17860
437 BLUE CHURCH RD
PPL ELECTRIC UTILITIES CORPORATION
MADAMS@FIRSTENERGYCORP.COM
ATTN: MELLYSSA ADAMS
AKRON, OH. 44320
341 WHITE POND DR
METROPOLITAN EDISON CO/FIRST ENERGY CORPORATION
LIST OF UTILITIES:
PURPLE - NON-POTABLE WATER, IRRIGATION OR SLURRY LINES
WHITE - PROPOSED EXCAVATION
GREEN - SEWERS AND DRAIN LINES
BLUE - POTABLE WATER
ORANGE - COMMUNICATION, ALARM OR SIGNAL LINES, CABLES OR CONDUIT
YELLOW - GAS, OIL, STEAM, PETROLEUM OR GASEOUS MATERIALS
RED - ELECTRIC POWER LINES, CABLES, CONDUIT AND LIGHTING CODES
COLOR CODES. KNOW THEM!
ACT NO. 287 OF 1974 AS AMENDED STANDARDIZES THE COLOR-MARKING OF UNDERGROUND UTILITIES IN ACCORDANCE WITH UNIFORM
SERIAL NO.: 20261942896
THIS PROJECT HAS A SERIAL NUMBER REGISTERED WITH THE ONE CALL SYSTEM, INC. USE IT!
GENERAL NOTES
KEY MAP
REMOVE EXISTING PAVERS
SEE SHEET C-102 FOR MORE DETAIL
INSTALL ADA SIDEWALK TO EXISTING MAILBOX
C-101
OF PENNSYLVANIA.
THAN 90 WORKING DAYS NOTICE WHEN ENGAGED IN THE DESIGN PHASE. THESE REQUIREMENTS APPLY ANYWHERE IN THE COMMONWEALTH
RIP, SCRAPE, TRENCH, TUNNEL OR DEMOLISH. ACT NO. 187 REQUIRES DESIGNERS TO GIVE NO LESS THAN 10 WORKING DAYS NOR MORE
EARTH (WITH OR WITHOUT EXPLOSIVES), ANCHOR, AUGER, BACKFILL, BLAST, BORE, DIG, DITCH, DRILL, DRIVE-IN, GRADE, PLOW-IN, PULL-IN, DAYS NOTICE NOR MORE THAN 10 WORKING DAYS NOTICE FROM EXCAVATORS/DEMOLITION CONTRACTORS WHO ARE ABOUT TO MOVE
PENNSYLVANIA ACT NO. 287 OF 1974 AS AMENDED, THE UNDERGROUND UTILITY LINE PROTECTION LAW, REQUIRES NO LESS THAN 3 WORKING
1-800-242-1776
PENNSYLVANIA ONE CALL SYSTEM, INC.
STOP-CALL BEFORE YOU DIG!
THROUGHOUT THE PROJECT AREA.
CONTRACTOR SHALL BE MADE AWARE THAT LOW LYING OVERHEAD UTILITY LINES (POWER, TELEPHONE, CABLE TV, ETC.) MAY EXIST
UNDERGROUND UTILITIES IS ON THE CONTRACTOR AND NOT ON THE PROJECT OWNER, BENESCH, OR THEIR REPRESENTATIVES.
THE RISK OF FINANCIAL LOSS RESULTING FROM MISIDENTIFICATION, MISLOCATION OR MISUNDERSTANDING OF THE LOCATION OF THE
DAMAGE HAS OCCURRED.
THE CONTRACTOR SHALL REPAIR DAMAGED SEWER LATERALS AND/OR WATER SERVICE LINES WITHIN THE SAME WORKING DAY THAT THE
ALL SHORING FOR TRENCHES WILL BE IN ACCORDANCE WITH OSHA STANDARDS AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.
SEDIMENTATION CONTROL MANUAL" AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.
CONSTRUCTION. SEE SEDIMENT AND EROSION CONTROL NOTES AND DETAILS. ALL CONTROLS SHALL CONFORM TO "EROSION AND
ALL REQUIRED SOIL EROSION AND SEDIMENTATION CONTROLS SHALL BE PROVIDED, INSTALLED AND MAINTAINED DURING ALL PHASES OF
AMERICAN VERTICAL DATUM OF 1988.
HORIZONTAL CONTROL IS BASED ON PA STATE PLANE COORDINATE SYSTEM (SOUTH ZONE) NAD83. VERTICAL CONTROL IS BASED ON NORTH
RIGHT-OF-WAY FOR TOWNSHIP ROADWAYS ARE RECORDED FROM SCHUYLKILL COUNTY TAX MAPS AND ARE APPROXIMATE.
TO ANY WORK.
EXCEPT WHERE SPECIFICALLY SHOWN. CHANGES TO LIMIT OF WORK BY THE CONTRACTOR MUST BE APPROVED BY THE ENGINEER PRIOR
MATCH PROPOSED PAVING ELEVATION TO EXISTING PAVING ELEVATIONS WHEREVER THEY ADJOIN. LIMIT OF WORK SHOWN IS APPROXIMATE
AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL STAKEOUTS BASED ON THE CONTRACT DRAWINGS AND SPECIFICATIONS
PROPER EXCAVATION SUPPORT SYSTEMS, BACKFILL, COVER, OR FENCE TO PROTECT EXCAVATION AREAS DURING NON-WORKING HOURS.
THIS PROJECT IS SUBJECT TO INSPECTION BY THE ENGINEER AND APPLICABLE CODE ENFORCEMENT AGENCIES. CONTRACTOR SHALL USE
THE OWNER RESERVES THE RIGHT TO ELIMINATE ANY OR ALL OF THIS WORK.
PUBLICATION 408 IN ITS LATEST REVISION.
PENNDOT SPECIFICATIONS SHALL MEAN COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS
CONSTRUCTION TO PREVENT DAMAGE TO PIPES AND APPURTENANCES.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THERE IS SUFFICIENT COVER ON EXISTING PIPING DURING
PLAN LOCATIONS AND DIMENSIONS SHALL BE STRICTLY ADHERED TO UNLESS OTHERWISE DIRECTED BY THE OWNER OR THE ENGINEER.
THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.
RESPONSIBILITY TO VERIFY AND ALLOW FOR THEIR LOCATIONS AND PROVIDE FOR THEIR PROTECTION. THE OWNER DOES NOT GUARANTEE
EXISTING UTILITIES ARE SHOWN IN ACCORDANCE WITH THE BEST AVAILABLE INFORMATION. IT SHALL BE THE CONTRACTOR'S
THE CONTRACTOR SHALL COORDINATE ALL WORK WITH UTILITY COMPANIES INVOLVED.
DIRECTED BY THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER.
ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR REPLACED TO THEIR ORIGINAL CONDITION AS
PRIOR TO CONSTRUCTION ACTIVITIES. ANY DISCREPENCIES SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ENGINEER.
ALL DIMENSIONS, EXISTING CONDITIONS AND PROPOSED QUANTITIES SHALL BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR
CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS AND PAY THE REQUIRED FEE.
THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS APPLICABLE TO CONSTRUCTION OF THIS SITE. THE
RESTORE AREA AROUND CONSTRUCTION
SEE ARCHITECTURAL PLANS FOR INTERIOR IMPROVEMENTS
POINT
CONTROL
TYPE ELEV.
COORDINATES
NORTH EAST
CP NO.1 MAG NAIL 604.77' 447726.93 2340388.73
2340263.19447657.40607.38'MAG NAILCP NO.2
CP NO.3 MAG NAIL 598.12' 447598.07 2340359.78
SURVEY TRAVERSE CONTROL POINT COORDINATES
GENERAL NOTES
SIDEWALK DETAILS
DESCRIPTION SHEET
C-102
C-103
C-104
C-101
E&S DETAILS
E&S NOTES
SHEET INDEX
0 200100 FEET
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE077612
JAMES STEVEN TOHILL
Sheet No.:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Pine Grove Township, Schuylkill County, Pennsylvania
ADA IMPROVEMENT PROJECT - PHASE III
CDBG TOWNSHIP BUILDING
PINE GROVE TOWNSHIP
9/17/2026 0326-609043.26
$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$
POINT NOTES
ME
ME
ME
LEGEND
MAILBOX SIDEWALK
NORTHING EASTING TS ELEV
A1
2340313.09447677.28
2340306.46447678.09
2340303.11447691.85
2340297.55447714.68
2340296.37447719.54
2340301.22447720.72
6.72'
0.45%
.2
.4
EXISTING MAILBOX TO REMAIN
4" SUBBASE
ITEM QUANTITY
TOPSOIL/SEEDING/MULCH
4" CONCRETE
19 SY
31 SY
31 SY
- LAWN RESTORATION
- PROPOSED CONCRETE SURFACE
- POINT & REFERENCE NUMBER
SIDEWALK DETAILS
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
ME
607.602340309.14447688.19
2340310.01447690.42
2340316.77447687.93
2340304.29447686.69
MAILBOX SIDEWALK SLOPES & ELEVATION DETAIL
ESTIMATE OF QUANTITIES (FOR INFORMATION ONLY)
REMOVE EXISTING PAVERS
EXISTING SIDEWALK
A2
A9
C-102
.1
.5
7.21'
1.80%
.2
5'
0.60%
5'
1.80%
447715.86
447693.03
2340302.41
2340307.96
607.60
607.47
607.63
607.60
607.55
607.53
607.47
607.46
607.37
607.44
607.50
5.00'
0.60%
NTS
SUBGRADE
PROOF ROLL
TO CONSTRUCTION)
PROCTOR (EXCAVATION INCIDENTAL
AND ROLLED TO 97% STANDARD
4" NO. 2A STONE COMPACTED
THE INSPECTOR-IN-CHARGE PRIOR TO CONCRETE PLACEMENT.
SUFFFICIENT LONGITUDINAL SLOPE. THESE LOCATIONS SHALL BE APPROVED BY
SIDEWALK CROSS SLOPE MAY BE 0% IN ISOLATED LOCATIONS WHICH HAVE 3.
DEPTH (TYP)
TOPSOIL AND SEED DISTURBED AREAS AS NECESSARY. MINIMUM 4" TOPSOIL 2.
CONSTRUCTION OF SIDEWALK.
RANGE SHALL BE REPORTED TO THE INSPECTOR IN CHARGE PRIOR TO
AND 2% MAXIMUM TOWARD CURB. ANY SIDEWALK AREAS THAT DO NOT MEET THIS
A 4'-0" (MIN) SIDEWALK ACCESSIBLE ROUTE SHALL SLOPE 0.5% MINIMUM 1.
NOTES:
SCORED JOINTS AT 5'-0" O.C.
20'-0" MAXIMUM
½" PREMOLDED EXPANSION MATERIAL AT
VARIABLE WIDTH - SEE DETAIL
GROUND
EXISTING
ACCESS PATH DETAIL
A1
A12
A3
A4
A11
A10
A8
A7
A6
A5
EXISTING SIDEWALK
EXPANSION JOINT
REPLACE TO EXISTING
EXPANSION JOINT
REPLACE TO EXISTING
.8
.0
.0
.4
.0
.0
5.00'
1.00%
.5
.2
.5
.2
ME = MATCH EXISTING
TS ELEV = TOP OF SIDEWALK ELEVATION
4" CONCRETE CLASS AAA
.4
EXISTING PAVER REMOVAL 9 SY
½" = 1'-0"
1 0 1 2 FEET
½" = 1'-0"
1 0 1 2 FEET
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE077612
JAMES STEVEN TOHILL
Sheet No.:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Pine Grove Township, Schuylkill County, Pennsylvania
ADA IMPROVEMENT PROJECT - PHASE III
CDBG TOWNSHIP BUILDING
PINE GROVE TOWNSHIP
9/17/2026 0326-609043.26
$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$
E&S NOTES
C-103
EROSION CONTROL POLICIES AND MAINTENNANCE PROGRAM
$25,000 IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH VIOLATION.
UP TO $10,000 PER DAY IN CIVIL PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND UP TO
DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW. THE CLEAN STREAMS LAW PROVIDES FOR
MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL PENALTIES BEING INSTITUTED BY THE DEPARTMENT AS
CONSTRUCTION SITE, OR FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE FAILURE OF E&S BMPS
FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT SEDIMENT-LADEN RUNOFF FROM LEAVING THE 31.
GERMINATING SEASON.
RAPID REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE ONLY DURING THE
DURING REMOVAL OR CONVERSION OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE
CONVERTED TO PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS DISTURBED
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY E&S BMPS MUST BE REMOVED OR 30.
INSPECTION PRIOR TO REMOVAL/CONVERSION OF THE E&S BMPS.
AREAS, THE OWNER AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT OR PADEP FOR AN
UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED 29.
STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER BMP APPROVED BY THE COUNTY.
E&S BMPS MUST REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO THEM ARE PERMANENTLY 28.
FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND
PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER 27.
STABILIZED IN ACCORDANCE WITH THE PERMANENT STABILIZATION SPECIFICATIONS.
STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE
WHICH WILL BE REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY
PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, OPERATOR SHALL STABILIZE ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH OR
IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR SUBAREA OF THE PROJECT, THE 26.
THE STANDARDS OF THIS PLAN.
A SURFACE WATER, OR AS OTHERWISE SHOWN ON THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO
SLOPES IN COMPETENT BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS WITHIN 50 FEET OF
ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON REACHING FINISHED GRADE. CUT 25.
STANDARD SPECIFICATION FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.
SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN ACCORDANCE WITH THE 24.
FILLS SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.23.
FILLS.
FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL NOT BE INCORPORATED INTO 22.
OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.
FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR OTHER FOREIGN OR 21.
ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9 INCHES IN THICKNESS.20.
BE COMPACTED IN ACCORDANCE WITH LOCAL REQUIREMENTS OR CODES.
OTHER RELATED PROBLEMS. FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC. SHALL
ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, SETTLEMENT, SUBSIDENCE OR 19.
MINIMUM OF 2 INCHES OF TOPSOIL.
MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A
INCHES ON COMPACTED SOILS - PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A
AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3 TO 5 INCHES - 6 TO 12 18.
DRAWINGS.
ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER DESCRIBED ON THE PLAN 17.
SURFACE WATER.
SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR
SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO CASE
SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO THE CONSTRUCTION 16.
OFFICIALS AT THE TIME OF INSPECTION.
THEY WERE CORRECTED SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE TO REGULATORY AGENCY
A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY DEFICIENCIES FOUND AND THE DATE 15.
REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.
REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF E&S BMPS FAIL TO PERFORM AS EXPECTED, REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, INSPECTIONS OF ALL E&S BMPS AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND
UNTIL THE SITE IS STABILIZED, ALL E&S BMPS MUST BE MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE 14.
NOT BE DISTURBED IN 4 DAYS.
THE CONTRACTOR MUST IMPLEMENT TEMPORARY STABILIZATION MEASURES IN ANY DISTURBED AREA THAT WILL 13.
THIS PLAN, OVER UNDISTURBED VEGETATED AREAS.
ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE ACCORDING TO THE PROCEDURE DESCRIBED IN 12.
OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING.
FP-001 MUST BE RETAINED BY THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE
THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN FILL. FORM 11.
PRIOR TO BEING ACTIVATED.
ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY PADEP FULLY IMPLEMENTED 10.
BURNED, BURIED, DUMPED, OR DISCHARGED AT THE SITE.
SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS, WASTES, OR UNUSED BUILDING MATERIALS SHALL BE
ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA. CODE 260.1 ET
ALL BUILDING MATERIALS AND WASTES MUST BE REMOVED FROM THE SITE AND RECYCLED OR DISPOSED OF IN 9.
THE REGIONAL OFFICE OF THE DEPARTMENT.
POTENTIAL FOR EROSION AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION DISTRICT AND/OR
EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BMPS TO MINIMIZE THE
IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR ACCELERATED 8.
2H:1V OR FLATTER.
SHOWN ON THE PLAN DRAWINGS. STOCKPILE HEIGHTS MUST NOT EXCEED 35 FEET. STOCKPILE SLOPES MUST BE
AREAS THAT ARE TO BE STABILIZED BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE MANNER
APPROVED BY THE TOWNSHIP IN THE AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL EXPOSED
TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED AT THE LOCATION 7.
DESCRIBED IN THIS E&S PLAN.
SPECIFIED BY THE BMP SEQUENCE FOR THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING AS
COMMENCE IN ANY STAGE OR PHASE OF THE PROJECT UNTIL THE E&S BEST MANAGEMENT PRACTICES (BMPS)
OF THE CONSTRUCTION SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT
CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN EACH STAGE 6.
VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.
AREAS TO BE FILLED SHOULD BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE TREES, 5.
TO IMPLEMENTATION.
PLAN DRAWINGS. DEVIATION FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE COUNTY PRIOR
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE SEQUENCE PROVIDED ON THE 4.
THE LOCATION OF EXISTING UNDERGROUND UTILITIES.
PREVIOUSLY UNMARKED, THE PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT 1-800-242-1776 FOR
AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR EXPANDING INTO AN AREA 3.
MUNICIPAL OFFICIALS AND THE E&S PLAN PREPARER TO AN ON-SITE PRECONSTRUCTION MEETING.
GRUBBING, THE OWNER AND/OR OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER, APPROPRIATE
AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, INCLUDING CLEARING AND 2.
THOSE CHANGES FOR REVIEW AND APPROVAL AT ITS DISCRETION.
PLAN PRIOR TO IMPLEMENTATION OF THOSE CHANGES. THE OWNER MAY REQUIRE A WRITTEN SUBMITTAL OF
BE AVAILABLE AT THE PROJECT SITE AT ALL TIMES. THE OWNER SHALL BE NOTIFIED OF ANY CHANGES TO THE
ACCORDANCE WITH THE EROSION AND SEDIMENTATION CONTROL (E&S) PLAN. A COPY OF THE DRAWINGS MUST
ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS AND FILL SHALL BE DONE IN 1.
DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THE ENGINEERS REPRESENTATIVE:
FOLLOWING GUIDELINES AS THEY ARE APPLICABLE AND IN ACCORDANCE TO THE INSTRUCTIONS OF THE
CONTROL EROSION, IT IS REQUIRED THAT THE CONTRACTOR FOR THIS PROJECT CONFORMS WITH THE
IN ACCORDANCE WITH THE CURRENT POLICIES AND PRACTICES IN THE COMMONWEALTH OF PENNSYLVANIA TO
DURING THE GERMINATING SEASON.
ENSURE RAPID REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE ONLY
DISTURBED DURING REMOVAL OR CONVERSION OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO
REMOVED OR CONVERTED TO PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS
AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT BMPS MUST BE 11.
FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.
PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND
PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER 10.
REMOVE TRAFFIC CONTROL DEVICES. 9.
STABILIZE ALL REMAINING DISTURBED AREAS.8.
SUBBASE PRIOR TO A FORECASTED SIGNIFICANT RAINFALL EVENT.
EXCAVATE AND CONSTRUCT SIDEWALK ADDITION. IN NO CASE SHALL AN AREA EXCAVATED BE WITHOUT STONE 7.
INSTALL REQUIRED TRAFFIC CONTROL DEVICES. 6.
COMPOST FILTER SOCK.
CONTROL SEDIMENT DURING THESE OPERATIONS. TEMPORARY CONTROLS INCLUDE CONCRETE WASHOUT, PRIOR TO THE START OF GRUBBING AND EXCAVATION, PLACE TEMPORARY EROSION CONTROL FEATURES TO 5.
AND ARE FUNCTIONING AS DESCRIBED IN THIS DOCUMENT.
TOPSOIL STRIPPING UNTIL THE E&S BMPS SPECIFIED BY THE CONSTRUCTION SEQUENCE HAVE BEEN INSTALLED
DESCRIBED IN THE CONSTRUCTION SEQUENCE. DO NOT COMMENCE GENERAL SITE CLEARING, GRUBBING AND
CLEAR THE SITE AS REQUIRED. LIMIT CLEARING, GRUBBING, AND TOPSOIL STRIPPING TO THOSE AREAS 4.
UTILITIES.
ACTIVITIES SHOULD NOTIFY THE PENNSYLVANIA ONE-CALL SYSTEM, INC. AT 1-800-242-1776 TO LOCATE BURIED
LEAST 3 DAYS BEFORE STARTING ANY EARTH DISTURBING ACTIVITIES, ALL CONTRACTORS INVOLVED IN THOSE
PLAN PREPARER, A REPRESENTATIVE OF THE COUNTY, FOR AN ON-SITE RECONSTRUCTION MEETING. ALSO, AT
INVITE ALL CONTRACTORS INVOLVED IN THOSE ACTIVITIES, THE EROSION AND SEDIMENT POLLUTION CONTROL
AT LEAST 7 DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, THE GENERAL CONTRACTOR SHALL 3.
CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED ONLY TO THOSE AREAS IN EACH STAGE.
STAGE SHALL BE COMPLETED AND IMMEDIATELY STABILIZED BEFORE ANY FOLLOWING STAGE IS INITIATED.
ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH 1.
CONSTRUCTION SEQUENCE
N
N S Y L V
A
N
I A
C O
M
M O
REGISTERED
PROFESSIONAL
ENGINEER
PE077612
JAMES STEVEN TOHILL
Sheet No.:
Rev Date By Chk'd Description
Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.
Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or
570-622-4055
Pottsville, Pennsylvania 17901
400 One Norwegian Plaza
Pine Grove Township, Schuylkill County, Pennsylvania
ADA IMPROVEMENT PROJECT - PHASE III
CDBG TOWNSHIP BUILDING
PINE GROVE TOWNSHIP
9/17/2026 0326-609043.26
$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$
E&S DETAILS
C-104
(LB/ACRE)
LB/1000 SQ YD
SEEDING RATE
WEED SEED
MAX. %
GERMINATIONPURITY
MINIMUM %
FORMULA AND SPECIES
TABLE A
WEIGHT
% BY
FORMULA B RESIDENTIAL MIX:
VARIETY EXCEEDING 50% OF THE TOTAL BLUEGRASS COMPONENT.
COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE
KENTUCKY BLUEGRASS MIXTURE (POA PRATENSIS). A
OR SSP COMMUTATE) (IMPROVED AND CERTIFIED)
CREEPING RED FESCUE OR CHEWINGS FESCUE (FESTUCA RUBRA
VARIETY EXCEEDING 50% OF THE TOTAL RYEGRASS COMPONENT.
COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE
PERENNIAL RYEGRASS MIXTURE (LOLIUM PERENNE). A
0.15
0.10
0.10
21.0 (105)
12.5 (62.5)
8.5 (42.5)
42.0 (210) TOTAL
FORMULA T TEMPORARY GRASS MIX:
CEREAL RYE (SECALE CEREALE) (FALL)
OATS (AVENA SATIVA) (SPRING)
0.1
0.1
6 (30)
6 (30)
6 (30) TOTAL
*IF A SPECIES IS UNAVAILABLE IN THIS MIX, SUBSTITUTE BY INCREASING THE PERCENTAGE OF OTHER ITEMS IN THE MIX.
SEEDING SEASON DATES:
MULCHING RATE:
MULCH TYPE:
LIMING RATE:
FERTILIZER APPL RATE
FERTILIZER TYPE:
APPLICATION RATE:
% PURE LIVE SEED:
SPECIES:
/15 TO 6/1 & 8/1 TO 10/153
HAY
6.0
SEE TABLE A
FORMULA T TEMPORARY GRASS MIX(TEMPORARY)
LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
SEEDING SEASON DATES:
ANCHORING METHOD:
RATE OF ANCHOR MATERIAL APPL:
ANCHOR MATERIAL:
MULCHING RATE:
MULCH TYPE:
LIMING RATE:
FERTILIZER APPL RATE
FERTILIZER TYPE:
APPLICATION RATE:
% PURE LIVE SEED:
SPECIES:(PERMANENT, <3:1 SLOPES)
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
LB/1000 SY
(X-X-X)
LB/1000 SY
/15 TO 6/1 & 8/1 TO 10/153
PER MANUFACTURERS' INSTRUCTIONS
STRAW
42.0
SEE TABLE A
FORMULA B RESIDENTIAL MIX
10-20-20
38-0-0 UREAFORM
59 TO 50 AS DIRECTED
32-0-0 TO 38-0-0 SULFER COATED UREA
31-0-0
10-20-20
38-0-0 UREAFORM
59 TO 50 AS DIRECTED
32-0-0 TO 38-0-0 SULFER COATED UREA
31-0-0
PER MANUFACTURERS' INSTRUCTIONS
POLYVINYL ACETATE
RECYCLED CELLULOSE FIBER/WOOD FIBER MIXTURE
RECYCLED CELLULOSE FIBER
WOOD FIBER
PER MANUFACTURERS' INSTRUCTIONS
NONASPHALTIC EMULSION
AND OROR
AND OR OR
ORAND
OR OR
SCHEDULE OF SEEING AND SOIL SUPPLEMENTS
TABLE B
T
B
FORMULA
TEMPORARY SEEDING
NON-STEEP, HIGHLY MAINTAINED SURFACES, LAWN
APPLICATION
NTS
SECTION VIEW
PLAN VIEW
AREA
UNDISTURBED
UNDISTURBED AREADISTURBED AREA
AREA
DISTURBED
M
IN
BLOWN / PLACED FILTER MEDIA COMPOST FILTER SOCK
2" x 2" WOODEN STAKES PLACED 10' OC
PLACED 10' OC (TYP)
2" x 2" WOODEN STAKES COMPOST FILTER SOCK
F L O
W F L O
W
CONTOURS
EXISTING
JOINING DETAIL
MIN
12"
STAKE
COMPOST FILTER SOCK
COMPOST SOCK FABRIC MINIMUM SPECIFICATIONS
TWO-PLY SYSTEMS
SOCK FABRICS COMPOSED OF BURLAP MAY BE USED ON PROJECTS LASTING 6 MONTHS OR LESS
MATERIAL TYPE
CHARACTERISTICS
MATERIAL
DIAMETERS
SOCK
MESH OPENING
STRENGTH
TENSILE
(ASTM-G-155)
STRENGTH
ORIGINAL
STABILITY %
ULTRAVIOLET
LONGEVITY
FUNCTIONAL
MINIMUM
3 MIL HDPE
DEGRADABLE
PHOTO-
18"
12"
3/8"
1000 HR
23% AT
6 MONTHS
5 MIL HDPE
DEGRADABLE
PHOTO-
32"
24"
18"
12"
3/8"
26 PSI
1000 HR
23% AT
9 MONTHS
5 MIL HDPE
DEGRADABLE
BIO-
32"
24"
18"
12"
3/8"
26 PSI
6 MONTHS
(MFPP)
POLYPROPYLENE
MULTI-FILAMENT
DEGRADABLE
PHOTO-
32"
24"
18"
12"
3/8"
44 PSI
1000 HR
100% AT
1 YEAR
(HDMFPP)
POLYPROPYLENE
MULTI-FILAMENT
HEAVY DUTY
DEGRADABLE
PHOTO-
32"
24"
18"
12"
1/8"
202 PSI
1000 HR
100% AT
2 YEARS
INNER CONTAINMENT NETTING
OUTER FILTRATION MESH
HDPE BIAXIAL NET
CONTINUOUSLY WOUND
FUSION-WELDED JUNCTURES
3/4" X 3/4" MAX APERTURE SIZE
MECHANICALLY FUSED VIA NEEDLE PUNCH)
(WOVEN LAYER AND NON-WOVEN FLEECE
COMPOSITE POLYPROPYLENE FABRIC
3 /16" MAX APERTURE SIZE
ALTERNATIVE.
TABLE BELOW. THE STANDARDS CONTAINED IN THE PENNDOT PUBLICATION 408 ARE AN ACCEPTABLE
THE PHYSICAL PARAMETERS OF THE COMPOST SHOULD COMPLY WITH THE STANDARDS AS SHOWN IN THE
ACCEPTABLE AS THE ORGANIC COMPONENT OF THE MIX.
AND BARK CHIPS, GROUND CONSTRUCTION DEBRIS OR REPROCESSED WOOD PRODUCTS ARE NOT
COMPOST PRODUCT SHOULD NOT RESEMBLE THE RAW MATERIAL FROM WHICH IT WAS DERIVED. WOOD
ODORS AND SHOULD BE SEASONABLY FREE (<1% BY DRY WEIGHT) OF MAN-MADE FOREIGN MATTER. THE
COMPOST SHOULD BE AEROBICALLY COMPOSTED. THE COMPOST SHOULD POSSESS NO OBJECTIONABLE
AGRICULTURE, FOOD, STUMP GRINDINGS, AND YARD OR WOOD/BARK ORGANIC MATTER SOURCES. THE
COMPOST SHOULD BE A WELL DECOMPOSED, WEED-FREE ORGANIC MATTER DERIVED FROM
COMPOST STANDARDS
SOLUBLE SALT CONCENTRATION
PARTICLE SIZE
MOISTURE CONTENT
pH
ORGANIC PORTION
ORGANIC MATTER CONTENT
5.0 DS/M (MMHOS/CM) MAXIMUM
30% - 50% PASS THROUGH 3/8" SCREEN
30% - 60%
5.5 - 8.5
FIBROUS AND ELONGATED
25% - 100% (DRY WEIGHT BASIS)
NOT TO SCALE
HEIGHT.
FILTER SOCK MAY BE STACKED ONTO DOUBLE 24" DIAMETER SOCKS IN PYRAMIDAL CONFIGURATION FOR ADDED
COMPOST SOCKS MAY BE STACKED AND STAKED SO AS TO FORM A TRIANGULAR CROSS SECTION. 18-INCH DIAMETER
PLASTIC LINERS SHOULD BE REPLACED WITH EACH CLEANING OF THE WASHOUT FACILITY.
ACCUMULATED MATERIALS SHOULD BE REMOVED WHEN THEY REACH 75% CAPACITY.
IMMEDIATELY.
INSPECT WASHOUT FACILITIES DAILY. DEACTIVATE AND REPAIR OR REPLACE DAMAGE OR LEAKING WASHOUTS
OF WHEN THEY REACH THE CLEANOUT LEVEL.
THAT THEY ARE WATERTIGHT, AND APPROPRIATELY SIZED. ACCUMULATED MATERIALS MUST BE PROPERLY DISPOSED
ENSURE THAT THE CONTAINERS ARE INTENDED BY THE MANUFACTURER FOR USE AS CONCRETE WASHOUT BMPS, PREFABRICATED WASHOUT CONTAINERS MAY BE USED AS A SUITABLE ALTERNATIVE. CARE SHOULD BE TAKEN TO
NOTES:
PLAN VIEW
SPACED 5' OC (TYP)
2" x 2" x 36" WOOD STAKES
FILTER RING
ON UPSLOPE SIDE OF
SOCK 4' MIN OVERLAP
24" COMPOST FILTER
INTO FILTER RING
WASHOUT WATER
DIRECT CONCRETE
COMPOST SOCK CONRETE WASHOUT
SUPPLEMENT.
AND VEGETATED OR REMOVED. IN THE LATTER CASE, THE MESH SHALL BE CUT OPEN AND THE MULCH SPREAD AS A SOIL
UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE REMOVED. THE SOCK MAY BE LEFT IN PLACE 7.
POLYPROPYLENE SOCKS SHALL BE REPLACED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
BIODEGRADABLE FILTER SOCKS SHALL BE REPLACED AFTER 6 MONTHS; PHOTODEGRADABLE SOCKS AFTER 1 YEAR. 6.
MANUFACTURER'S SPECIFICATIONS OR REPLACED WITHIN 24 HOURS OF INSPECTION.
SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. DAMAGED SOCKS SHALL BE REPAIRED ACCORDING TO 5.
DISPOSED IN THE MANNER DESCRIBED ELSEWHERE IN THE PLAN.
ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE ABOVEGROUND HEIGHT OF THE SOCK AND 4.
TRAFFIC SHALL NOT BE PERMITTED TO CROSS FILTER SOCKS.3.
SPECIFIED BY THE MANUFACTURER.
CONTROL PROGRAM MANUAL (363-2134-008). STAKES MAY BE INSTALLED IMMEDIATELY DOWNSLOPE OF THE SOCK IF SO
EXCEED THAT IN THE EROSION AND SEDIMENT CONTROL REPORT AND/OR THE PADEP EROSION AND SEDIMENT POLLUTION
8 FEET UP SLOPE AT 45 DEGREES TO THE MAIN SOCK ALIGNMENT. MAXIMUM SLOPE LENGTH ABOVE ANY SOCK SHALL NOT
COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF THE SOCK SHALL BE EXTENDED AT LEAST 2.
TABLE BELOW.
SOCK FABRIC SHALL MEET STANDARDS AS SHOWN IN TABLE BELOW. COMPOST SHALL MEET THE STANDARDS AS SHOWN IN 1.
NOTES:
A-102
7 5
NEW
ACCESSIBLE
UNISEX TOILET
EXISTING
(UNISEX) TOILET
EXISTING
LOBBY
<E> MEETING
ROOM
EXISTING
JANITOR
1' - 4" +/- 4' - 7 3/4" +/-
E X
IS
T
IN
G
L E
N G
T H
T O
R E
M A
IN
V .I
.F
EXISTING
STORAGE
EXISTING OPEN
OFFICE M
IN
2'-0" W x 5'-6" L x 34" H
LOW ADA COUNTERTOP
(LIGHT SHADED)
1'-10" W x 4'-4" L x 34" H
LOW ADA COUNTERTOP
(LIGHT SHADED)
60" x 60" CLEAR
SPACE AT DOOR
30" x 48" FORWARD
APPROACH
30" x 48" PARALLEL
APPROACH
30" x 48" FORWARD
APPROACH
NEW STUD WALL,
DOOR / FRAME AND
HARDWARE
1'-0" W x 4'-5" L x 42" H
HIGH COUNTERTOP
(DARK SHADED)
4' - 5" 1' - 10"
V .I
.F
48" x 60" CLEAR SPACE
AT SIDE APPROACH
5'-0" DIAMETER TURNING
SPACE AT CORRIDOR
A-102
A-101 2
A-1013
INFILL OPENING w/
WOOD STUD WALL
30" x 48" PARALLEL
APPROACH
A-101
LIMIT OF NEW
FLOOR FINISHES
LIMIT OF NEW
FLOOR FINISHES
IF TOTAL
REPLACEMENT
OF EXISTING
<E> FLOOR FINISHES
TO REMAIN
EXISTING
CORRIDOR
<E> FLOOR FINISHES
TO REMAIN
<E> FLOOR FINISHES
TO REMAIN
W01B
W01B
W01B
W01B
A-101
SIGN TYPE A
SIGN
TYPE B
A-101
SIGN
TYPE A1
SLIDER
C E
IL
IN
G H
E
IG
H T
V
.I .F
V A
R
IF
Y I N
F
IE
L D
H E
IG
H
T
MIN.
1' - 6"
WINDOW WIDTH
3' - 4" 1' - 0"
C O
U N
T E
R T
O P
H
IG
H
P A
T R
O N
C O
U N
T E
R T
O P
L O
W A
D A
1'-0" W x 4'-5" L x 42" HIGH PATRON COUNTERTOP w/
4" HIGH BACKSPLASH
CONTINUOUS CLEAT
RAXX COUNTER SUPPORT
MOUNTED WITHIN WALL
2'-0" W x 5'-6" L x 34" H
LOW ADA COUNTERTOP
3'-4" W x 4'-0" L SLIDER
TRANSACTION WINDOW
NEW BASE TO
MATCH EXISTING
PAINTED NEW DRYWALL -
COLOR TO BE SELECTED
BY OWNER
A-101
SIGN TYPE B
First Floor 8' - 8"
C O
U N
T E
R T
O P
H
IG
H
P A
T R
O N
2' - 0"1' - 10"
EXISTING WINDOW
TO REMAIN
1'-10" W x 4'-4" L x 34"H
LOW ADA
COUNTERTOP
CONTINUOUS CLEAT -
BOTH SIDES
RAXX COUNTER
SUPPORT MOUNTED
WITHIN WALL
(BOTH SIDES)
NEW BASE TO MATCH
EXISTING
BRACKET SUPPORTS AT
3'-0" (MAX.)
NEW BASE TO MATCH
EXISTING
EXISTING BASE
TO REMAIN
2'-0" W x 5'-6" L x 34" H
LOW ADA
COUNTERTOP
1'-0" W x 4'-5" L x 42" H HIGH PATRON COUNTERTOP w/ 4"
HIGH BACKSPLASH
EXISTING ENTRANCE
DOORS TO REMAIN
A-101
A-101
A-101
A-101
First Floor 8' - 8"
SLIDER
W
IN
D O
W H
E
IG
H T
C O
U N
T E
R T
O P
L O
W A
D A
2'-0" W x 4'-4" L x 34" H
LOW ADA COUNTERTOP
RAXX COUNTER
SUPPORT MOUNTED
WITHIN WALL
NEW BASE TO MATCH
EXISTING
V
E R
IF
Y
I N
F
IE
L D
C E
IL
IN
G H
E
IG
H T
A-101
PHASE 3 - GENERAL NOTES
GENERAL NOTES:
1.1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES,
AND SHALL CONFORM TO ALL APPLICABLE MUNICIPAL, STATE, AND FEDERAL
REGULATIONS HAVING JURISDICTION. (INCLUDING ACCESSIBILITY STANDARDS AND ADA
REQUIREMENTS).
1.2. NOT USED.
1.3. THE CONTRACTOR SHALL VISIT THE SITE AND BE KNOWLEDGEABLE OF CONDITIONS
THEREON. THEY SHALL INVESTIGATE, VERIFY, AND BE RESPONSIBLE FOR ALL CONDITIONS
OF THE PROJECT AND SHALL NOTIFY THE OWNER OF ANY SITE CONDITIONS REQUIRING
MODIFICATION BEFORE PROCEEDING WITH THE WORK.
1.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION AND CONTINUOUS
MAINTENANCE OF ALL WORK FROM DAMAGE AND SHALL PROTECT THE OWNERS’ PROPERTY
FROM DAMAGE OR LOSS BY DUST, DIRT, WATER, THEFT, FIRE OR ANY OTHER PHYSICAL
DAMAGE IN CONNECTION WITH THE CONTRACT.
1.5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL KNOWN UTILITIES AND
TO COORDINATE CONSTRUCTION AROUND KNOWN OR UNKNOWN UTILITIES.
1.6. THE ARCHITECT SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE,
HANDLING, REMOVAL, DISPOSAL, OR EXPOSURE OF PEOPLE TO HAZARDOUS MATERIALS IN
ANY FORM, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED
BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.
1.7. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE OF ANY CHANGES THAT INVOLVE
ADDITIONAL MONEY AND/OR TIME TO THE ARCHITECT AND OWNER WITHIN FIVE DAYS OF ITS
DISCOVERY AND BEFORE PROCEEDING WITH THE WORK. THIS SHALL BE SUBMITTED IN THE
FORM OF A UNIT COST, AND DETAILED LUMP SUM BREAKDOWN. COST EVENTS WITHOUT AN
ACCOMPANYING BREAKDOWN WILL NOT BE CONSIDERED FOR REVIEW AND APPROVAL.
PROCEED WITH WORK ONLY AFTER OWNER HAS APPROVED LUMP SUM.
1.8. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY BUILDING PERMITS
AND MUST BE LICENSED TO WORK WITHIN THE TOWNSHIP OR MUNICIPALITY WHERE THE
PROJECT IS LOCATED.
1.9. THE CONTRACT DOCUMENTS ARE A COMPLETE SET. GENERAL CONTRACTOR IS
RESPONSIBLE FOR ALL WORK REGARDLESS OF WHICH SHEET THE WORK IS SHOWN ON.
THE ARCHITECT RESERVES THE RIGHT TO SELECT WHICH WORK APPLIES WHEN
DISCREPANCIES OCCUR BETWEEN SHEETS EVEN IF THE SELECTION IS MORE STRINGENT.
1.10. ALL COLORS TO BE SELECTED BY OWNER FROM MANUFACTURERS FULL RANGE OF
COLORS INCLUDING NON-STANDARD COLORS.
1.11. INSTALL ALL MATERIALS IN ACCORDANCE WITH MANUFACTURERS INSTALLATION
REQUIREMENTS AND DETAILS INCLUDING ALL PREPARATION REQUIREMENTS AND PROVIDE
MANUFACTURERS FULL WARRANTIES.
1.12. ARCHITECT RESERVES THE RIGHT TO REQUIRE REPLACEMENT OF ANY MATERIAL NOT
PROPERLY INSTALLED OR DAMAGED DURING INSTALLATION.
1.13. FIELD PAINTING OR TOUCH-UP PAINTING OF PRE-FINISHED MATERIALS IS NOT
ACCEPTABLE WITHOUT PRIOR APPROVAL OF THE ARCHITECT.
1.14. PROVIDE JOINT SEALANT ADHESION TESTING FOR ALL JOINT SEALANT APPLICATIONS.
1.15. THE CONTRACTOR MUST NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES
AND ERRORS WITH ANY AND ALL OF THE CONSTRUCTION DOCUMENTS PRIOR TO BEGINNING
THE WORK.
1.16. THE CONTRACTOR SHALL COMPLY WITH, AND PERFORM ITS WORK IN ACCORDANCE
WITH ALL APPLICABLE LAWS, STATUTES, ORDINANCES,LAWFUL ORDERS OF
GOVERNMENTAL AUTHORITIES, BUILDING CODES, RULES AND REGULATIONS, UNLESS THE
CONTRACT DOCUMENTS REQUIRE A HIGHER OR GREATER STANDARD, IN WHICH CASE THE
CONTRACTOR SHALL CONFORM TO SUCH HIGHER OR GREATER STANDARD. IF THE
CONTRACTOR RECOGNIZES THAT PORTIONS OF THE CONTRACT DOCUMENTS DO NOT MEET
THE STANDARDS ESTABLISHED THEREBY, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE
ARCHITECT, THE CONSTRUCTION MANAGER (IF APPLICABLE) AND THE OWNER IN WRITING
BEFORE PROCEEDING WITH THE WORK.
1.17. EACH CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE WORK TO BE DONE AND
MATERIALS AND EQUIPMENT TO BE INSTALLED BY HIMSELF AND OTHERS, AND COORDINATE
IN ADVANCE, PRIOR TO INSTALLING ANY SYSTEM OR PORTION THEREOF.
1.18. EACH CONTRACTOR WHO FAILS TO COORDINATE THE INSTALLATION OF HIS WORK
WITH THE OTHER TRADES SHALL BEAR ALL COSTS OF EACH TRADE FOR DISCONNECTING,
REMOVAL AND RE-INSTALLATION OF AFFECTED SYSTEMS, EQUIPMENT OR PORTION
THEREOF.
1.19. CONTRACTOR TO COORDINATE ALL WORK WITH OWNER SUPPLIED ITEMS.
1.20. CLOSE OPENINGS AT DOORS AND FRAMES.
1.21. NOT USED.
1.22. GENERAL CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED IN WALLS TO
SUPPORT WALL-MOUNTED ITEMS, AND ACCESSORIES. COORDINATE REQUIREMENTS WITH
OWNER.
1.23. GENERAL CONTRACTOR TO REPLACE ANY DEFECTIVE MATERIALS AT THE DISCRETION
OF THE ARCHITECT.
1.24. ALL INTERIOR FINISH MATERIALS AND COLOR SELECTIONS ARE BY OWNER.
1.25. GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERALL PROJECT SCHEDULE AND
COORDINATING WORK WITH ALL SUB-CONTRACTORS.
1.26. PROVIDE SEALANT AS DIRECTED BY ARCHITECT FOR ALL BUILDING JOINTS. SEALANT
COLOR TO MATCH ADJACENT MATERIAL COLOR AND APPROVED BY ARCHITECT FROM FIELD
SAMPLE AND MAY REQUIRE CUSTOM COLOR.
1.27. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN
OVER ALL SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE PROFESSIONAL IN
WRITING OF ANY DISCREPANCIES, OMISSIONS AND / OR CONFLICTS BEFORE
COMMENCEMENT OF THE WORK.
1.28. THE CONTRACTOR SHALL PROTECT EXISTING WORK AND OTHER NEW WORK BY
OTHER CONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO
EXISTING WORK OR WORK BY OTHERS INCURRED WHILE FULFILLING THE OBLIGATION OF
THE CONTRACT.
1.29. THE CONTRACTOR SHALL PERFORM ALL NEW WORK IN ACCORDANCE WITH ALL
APPLICABLE CURRENT BUILDING CODES, ORDINANCES, REGULATIONS, AND ALL
ACCESSIBILITY AGENCIES, AND REQUIREMENTS BY AHJ.
1.30. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL INSPECTIONS AND
CERTIFICATES AND SHALL GIVE ALL LEGAL NOTICES.
1.31. ALL WORK SHALL CONFORM WITH APPLICABLE INDUSTRY AND MANUFACTURERS
PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS ALL
REQUIREMENTS IN THE DRAWINGS AND SPECIFICATIONS, ANY CONFLICTING REQUIREMENTS
OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE PROFESSIONAL'S ATTENTION
PRIOR TO PROCEEDING WITH THE WORK.
1.32. NO SUBSTITUTIONS FOR ITEMS SPECIFIED WILL BE ACCEPTED WITHOUT PRIOR
WRITTEN ACCEPTANCE FROM THE DESIGN PROFESSIONAL. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR SUPPLYING THE DESIGN PROFESSIONAL WITH ALL SAMPLES AND
COMPARATIVE PRODUCT DATA REQUIRED TO EVALUATE PROPOSED SUBSTITUTIONS IN A
TIMELY MANNER SO AS NOT TO PRECLUDE PROCUREMENT OF THE PRODUCT ORIGINALLY
SPECIFIED OR ANY PROPOSED SUBSTITUTE.
1.33. WHERE REFERENCE IS MADE IN THESE DOCUMENTS TO BUILDING / SUB-CONTRACTOR,
IT SHALL REFER TO BUILDER, GENERAL CONTRACTOR, AND ALL SUB-CONTRACTORS AND
THEIR EMPLOYEES.
1.34. SUB-CONTRACTOR OR BUILDER UNDERSTANDS THAT DRAWINGS GRAPHICALLY
DEPICT DESIGN INTENT OF THE PROJECT. LOCATIONS AND DIMENSIONS SHOWN ON
DRAWING ARE DIAGRAMMATIC. BUILDER/CONTRACTOR UNDERSTAND THAT DRAWINGS
SHOWN THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF WORK AND ARE NOT
INTENDED TO BE SCALED FOR MEASUREMENT OR SERVE AS SHOP DRAWINGS.
1.35. SUB-CONTRACTOR/BUILDER SHALL PROPERLY FABRICATE, TRANSPORT, INSTALL
ERECT, CONSTRUCT AND TEST, FURNISH AND SUPPLY ALL LABOR MATERIALS, EQUIPMENT,
APPARATUS, APPLIANCES, AND ALL OTHER ITEMS AND EXPENSES NECESSARY TO
PROPERLY COMPLETE THE WORK IN PLACE AND READY FOR OPERATION OR USE AS
INTENDED FOR BY THE ARCHITECT.
1.36. SUB-CONTRACTOR/BUILDER SHALL BE FAMILIAR WITH PROVISION OF ALL APPLICABLE
CODES, SHALL ENSURE COMPLIANCE WITH SAME AND SHALL BE RESPONSIBLE FOR AND BE
REQUIRED TO DISCOVER, THROUGH EXERCISING CARE, SKILL AND DILIGENCE IN REVIEWING
THE CONSTRUCTION DRAWINGS, ANY OMISSION, AND DISCREPANCIES AND SHALL BRING
SAME TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION.
1.37. BY EXECUTING THE CONTRACT, THE SUB-CONTRACTOR/BUILDER WARRANTS THAT HE
SHALL CLOSELY INSPECTED BUILDING, AND HAS DETERMINED TO HIS SATISFACTION THE
PHYSICAL CONDITION OF SUCH, FAMILIARIZED HIMSELF WITH THE LOCAL CONDITIONS
UNDER WHICH THE WORK IS TO BE PERFORMED, CORRELATED HIS OBSERVATIONS WITH
THE REQUIREMENTS OF THE CONSTRUCTION DRAWINGS, AND KNOWS OF NO OTHER
INFORMATION REQUIRED TO COMPLETE THE WORK AS INTENDED FOR BY THE ARCHITECT,
AND AS PER LOCAL JURISDICTION REQUIREMENTS.
1.38. IF ANY ITEM OR MATERIALS IS NOT KNOWN OR OMITTED ON THE DRAWINGS, BUT IS
OTHERWISE REASONABLY INFERABLE THEREFROM, THE SUB-CONTRACTOR/ BUILDER SHALL
INFORM ARCHITECT, AND BE REQUIRED TO FURNISH AND INSTALL SUCH ITEM OR MATERIAL
WHICH CONFORM TO THE TYPE AND QUALITY OF SIMILAR ITEMS OTHERWISE ESTABLISHED
IN THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS.
1.39. WHERE A TYPICAL DETAIL IS SHOWN OR INDICATED ON THE DRAWINGS, THAT
CONDITION SHALL BE REPRESENTATIVE OF AND SHALL CONSTITUTE THE STANDARD FOR
WORKMANSHIP, MATERIALS, AND PERFORMANCE FOR CONDITIONS AND MATERIALS AND
WORKMANSHIP THROUGHOUT CORRESPONDING CONDITION THROUGHOUT THE WORK.
1.40. THE SUB-CONTRACTOR/BUILDER ARE RESPONSIBLE FOR THOROUGHLY EXAMINING
ALL DRAWINGS, SPECIFICATIONS AND APPLICABLE CODES, AS WELL AS MAKING ALL ACTUAL
MEASUREMENTS AND ESTABLISHING ALL ACTUAL DIMENSIONS FOR EACH PARTICULAR TYPE
OF WORK, AND FOR CO-COORDINATING THE WORK DESCRIBED, AND ALSO RESPONSIBLE
FOR DETERMINING THE EXACT SCOPE OF WORK FOR EACH SECTION, AS WELL AS
CHECKING CROSS REFERENCES OF WORK, AND ANY WORK EXCLUDED FROM ANY SECTION.
ELECTRONIC DOCUMENTS:
1.1. GREENFIELD ARCHITECTS LTD. IS PROVIDING BY AGREEMENT, MATERIALS STORED
ELECTRONICALLY. THE PARTIES RECOGNIZE THAT DATA, PLANS, SPECIFICATIONS, REPORTS,
DOCUMENTS, OR OTHER INFORMATION RECORDED ON OR TRANSMITTED AS ELECTRONIC
MEDIA ARE SUBJECT TO UNDETECTABLE ALTERATION, EITHER INTENTIONAL OR
UNINTENTIONAL, DUE TO, AMONG OTHER CAUSES, TRANSMISSION, CONVERSION, MEDIA
DEGRADATION, SOFTWARE ERROR, OR HUMAN ALTERATION, ACCORDINGLY, ALL SUCH
DOCUMENTS ARE PROVIDED TO THE PARTIES FOR INFORMATIONAL PURPOSES ONLY AND NOT
AS AN END PRODUCT NOR AS A RECORD DOCUMENT. ANY RELIANCE THEREON IS DEEMED
TO BE UNREASONABLE AND UNENFORCEABLE. THE SIGNED AND/OR SEALED HARD COPIES OF
THE ARCHITECT'S INSTRUMENTS OF SERVICE ARE THE ONLY TRUE CONTRACT DOCUMENTS OF
RECORD.
DOCUMENTS, GENERAL:
1.1. PRIME CONTRACTORS FOR EACH TRADE ARE ADVISED THAT INFORMATION PERTINENT TO
THEIR WORK MAY OCCUR IN OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
1.2. SHOULD THERE BE ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS THAT
WOULD CAUSE AN AWKWARD OR IMPROPER OR EXPOSED INSTALLATION, IT SHALL BE
BROUGHT TO THE ARCHITECT’S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF
SAID WORK.
1.3. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE
CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR’S EXPENSE, AND AT NO ADDITIONAL
COST TO THE OWNER OR ARCHITECT.
1.4. ALL NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED BUILDING COMPONENTS.
NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. NOTES ON
ANY ONE SHEET ARE TO BE APPLIED TO RELATED DRAWING SHEETS AND DETAILS.
1.5. ANY DETAILS, SYSTEMS, OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST
FIRST BE REVIEWED BY THE OWNER, ARCHITECT, AND GENERAL CONTRACTOR PRIOR TO THE
PREPARATION OF SHOP DRAWINGS.
1.6. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND COORDINATE
ALL TRADES AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES
ARE FOUND, THEY SHALL BE BROUGHT TO THE ARCHITECT’S ATTENTION FOR CLARIFICATION
BEFORE COMMENCING WITH THE WORK.
1.7. DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS.
1.8. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC
DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT
BEFORE PROCEEDING WITH THE WORK.
1.9. PROVIDE ENTIRE SETS OF DRAWINGS TO SUB-CONTRACTORS FOR COORDINATION.
1.10. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION
SAFETY PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SAFETY
AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH STATE AND FEDERAL SAFETY GUIDE
LINES.
1.11. THE GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID THE HIGHEST QUALITY AND
GREATEST QUANTITY FOR RESOLVING ALL CONFLICTS IN THE CONSTRUCTION
DOCUMENTATION WHICH IS IMPLIED OR DEFINED.
1.12. NO CHANGES SHALL BE MADE TO THESE DOCUMENTS EITHER IN WHOLE OR IN PART
WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT.
MISCELLANEOUS NOTES:
1.1. ALL DISSIMILAR…
This is the start of the file's text. The full file is on GovTribe.