2-Pine Grove Twp Ph 3 Plan Set - Issued for Construction.pdf

PDF 6 MB Posted

Attached to
Schuylkill County, PA - Pine Grove Township, CDBG Building ADA Improvement - Phase III (0326-609043.26)
Solicitation number
US.258250
Issued by
Somerset County, Pennsylvania

About this file

This file is a plan set issued for construction for the Pine Grove Township Building ADA Improvement Project – Phase III, located at 175 Oak Grove Road, Pine Grove, Pennsylvania 17963, involving Schuylkill County and Pine Grove Township. The project encompasses ADA improvements to the municipal building's bathroom facilities and transaction counter, along with ADA-compliant sidewalk installation extending from the existing sidewalk to the mailbox. The work includes demolition and renovation of toilet areas, creation of new accessible unisex facilities, lobby modifications, and concrete sidewalk construction with proper drainage and grading. The total building area is 3,884 square feet. Sealed bids are due online via the PennBid Program by 9:00 AM on Wednesday, October 28, 2026, with public opening and tentative award on November 11, 2026. A non-mandatory pre-bid meeting is scheduled for Tuesday, October 20, 2026, at 9:30 AM at the Pine Grove Township Municipal building. The entire project will be awarded to a single contractor, and all bidding documents are available at no cost through PennBid.

The successful bidder must provide a bid bond in the amount of 10 percent of the total bid and will be required to furnish performance and payment bonds each equal to 100 percent of the contract price with an acceptable corporate surety. The project is funded through CDBG (Community Development Block Grant) funds. Contractors must comply with applicable codes including the 2018 International Building Code, 2017 ANSI A117.1, and 2010 ADA standards. The project is classified as Use Group B with Construction Type VB. Contractors are responsible for all utility coordination, erosion and sedimentation control measures, subsurface verification, and compliance with Pennsylvania Act 287 regarding underground utilities. Temporary and permanent stabilization measures, seeding specifications, and proper fill placement are detailed in the erosion and sediment control notes and specifications included in the plan set.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Room name

Occupancy Type

Occupancy Load

Occupancy Type

Occupancy Load Occ.

Occupancy Ratio

Area

S03BW-20101

XX

P-1

CONTROL LINE GRID LINE

ROOM TAG

CALLOUT

DOOR TAG WINDOW TAG PARTITION

TYPE

LENGTH AND

DIRECTION OF

TRAVEL (CODE)

SPACE OCCUPANCY

TYPE AND LOAD

(CODE)

DIRECTIONAL

ARROW

CENTERLINE PLUMBING

FIXTURE TAG

REVISION

CLOUD

HEARING

IMPAIRED

ACCESSIBLE

A-102

ELEVATION

CALLOUT

NOTE: TEXT IN SYMBOLS MAY

DIFFER FROM EXAMPLES SHOWN

XX'

XX'

SPOT ELEVATION

(ELEVATION OR

SECTION VIEW)

SPOT ELEVATION

(PLAN VIEW)

LEVEL

DATUM

SECTION CEILING

ELEVATION

(PLAN VIEW)

Name

Elevation

MATERIAL

@ 1'-0"

A101

SIM

P L

A N

N O

R T

H

TRUE NORTH

PLAN NORTH

A101

SIM

EXISTING

LOBBY

EXISTING OPEN

OFFICE

OFFICE

EXISTING

STORAGE

EXISTING

KITCHEN

NEW

ACCESSIBLE

UNISEX TOILET

EXISTING

JANITOR

<E> MEETING

ROOM

STAIRWELLCORR.

OFFICE

CORR.

OFFICE

OFFICE

NEW ADA

TOILET

PLANA-102

EXISTING

(UNISEX) TOILET

A-101

A-102

2 DEMO

PLAN

NEW

LOBBY

PLAN

A-102

3 CEILING

PLAN

EXISTING

CORRIDOR

Date

Drawn By

Checked By

Project Number

GREENFIELD ARCHITECTS, LTD.

These plans are copyrighted and are subject to copyright protection as an "architectural work" under Section 102 of the Copyright Act, 17 U.S.O. as amended December 1990 and known as Architectural Copyright Protection Act of 1990. The protection includes but is not limited to the overall form as well as the arrangement and composition of spaces and elements of design. Under such protection, anauthorized use of these plans, or work represented, can legally result in the penalties provided.

Any reproduction of this document in part or whole without the express written permission of Greenfield Architects, Ltd. is strictly prohibited.

ABCDEFGH

ABCDEFGH

/3

/2

:2

:3

A

M

TM

MJD

05/29/2026

26015

CDBG TOWNSHIP

BUILDING

ADA IMPROVEMENT

PROJECT - PHASE 3

PINE GROVE TOWNSHIP

175 OAK GROVE ROAD

PINE GROVE, PA 17963

A-001

COVER AND DATA SHEET -

PHASE 3

PROJECT NAME/ LOCATION

CDBG TOWNSHIP BUILDING

ADA IMPROVEMENT PROJECT - PHASE 1

PINE GROVE TOWNSHIP

175 OAK GROVE ROAD

PINE GROVE, PA 17693

ARCHITECT'S PROJECT NO.: 23020

APPLICABLE CODES

2018 IBC

2017 ANSI A117.1

2010 ADA

USE GROUP CLASSIFICATION

USE GROUP: B

CONSTRUCTION CLASSIFICATION

CONSTRUCTION TYPE: VB

BUILDING HEIGHT, STORIES, AND AREA

40' PERMITTED > 28' ACTUAL = OK

2 STORIES PERMITTED = 2 STORIES ACTURAL = OK

BUILDING AREA

BASEMENT FLOOR 1,726 SF

FIRST FLOOR 2,158 SF

TOTAL BUILDING 3,884 SF

9,000 SF PERMITTED > 2,158 SF ACTUAL = OK

BENESCH

400 One Norwegian Plaza Pottsville, PA 17901 Phone: 570-622-4055

Ryan Fasnacht, P.E., Senior Project Manager / Principal Associate rfasnacht@benesch.com Direct Phone: 570-624-4275 Mobile Phone: 570-294-7778 Office Phone: 570-622-4055

James Tohill, P.E.

Project Manager jtohill@benesch.com Direct Phone: 570-624-4282 Office Phone: 570-622-4055

OWNER'S REPRESENTATIVE

DORMAKABA AMERICAS

Eastern PA / Southern NJ / Delaware / Eastern Shore MD Phone: 267-377-4174 Fax: 866-232-0509

Benjamin Gorton, DAHC, DHT, DHC, CFDAI, QFDI, QDOC / CSI

Architectural Consulting Representative / Architectural Services / National Accounts benjamin.gorton@dormakaba.com www.dormakaba.us

HARDWARE CONSULTANT

GREENFIELD ARCHITECTS, LTD.

1853 William Penn Way Lancaster, PA 17601 Phone: 717-293-4475 Fax: 717-293-4499

Thomas Marcinkoski, AIA, Senior Project Architect tmarcinkoski@high.net Phone: 717-390-4614

ARCHITECT

DRAWING INDEX

LOCATION MAP

PROJECT DATA PROJECT DIRECTORYABBREVIATIONS

SYMBOL LEGEND

ACC

ACT

AFF

AHU

ALUM

AS

BF

BLK

BLK'G

BS

BLD'G

BOT

CIP

CLG

COL

CJ

CO

CONC

CMU

CONT

CPT

CPT TL

CT

DIAG

DIA

DO

DS

DF

DR

E

EA

EIFS

ES

ELEC

ELEV

EP

EQ

EQPM

EXIST

EXP

ACCESSIBLE

ACOUSTICAL LAY-IN CEILING

ABOVE FINISHED FLOOR

AIR HANDLING UNIT

ALUMINUM

ACTUAL SIZE

BROOM FINISH

BLOCK

BLOCKING

BOTH SIDES

BUILDING

BOTTOM

CAST-IN-PLACE

CEILING

COLUMN

CONTROL JOINT

CASED OPENING

CONCRETE

CONCRETE MASONRY UNIT

CONTINUOUS

CARPET

CARPET TILE

CERAMIC TILE

DIAGONAL

DIAMETER

DITTO

DOWNSPOUT

DRINKING FOUNTAIN

DOOR

EPOXY

EACH

EXTERIOR INSULATION & FINISH SYSTEM

EACH SIDE

ELECTRICAL

ELEVATION

EPOXY PAINT

EQUAL

EQUIPMENT

EXISTING

EXPANSION

EX STL

ET

EXT

EXP JT

EWC

FG

FTG

FT

FLG

FD

FE

FRP

GA

GALV

GM

GS

GB

GB LL

HCW

HDW

HVAC

HT

HM

HOR

IAL

ID

IGHM

IHM

INSUL

INT

IPL

IPFGM

ITGL

IWGL

IWP

JT

KD

LAM

LAV

EXPOSED STEEL

EPOXY TERRAZZO

EXTERIOR

EXPANSION JOINT

ELECTRIC WATER COOLER

FIBERGLASS

FOOTING

FEET

FLASHING

FLOOR DRAIN

FIRE EXTINGUISHER

FIBERGLASS REINFORCED PANEL

GAUGE

GALVANIZED

GALVANIZED METAL

GALVANIZED STEEL

GYPSUM BOARD

GYPSUM BOARD - LEAD LINED

HOLLOW CORE WOOD

HARDWARE

HEATING, VENTILATING AND AIR CONDITIONING

HEIGHT

HOLLOW METAL

HORIZONTAL

INSULATED ACRYLIC LITE

INSIDE DIAMETER

INSULATED GALVANIZED HOLLOW METAL

INSULATED HOLLOW METAL

INSULATED/ INSULATION

INTERIOR

INSULATED PLYWOOD LAMINATE

INSULATED PREFINISHED GALVANIZED METAL

INSULATED TEMPERED GLASS

INSULATED WIRE GLASS

INSULATED WALL PANEL

JOINT

KNOCKED DOWN

LAMINATE

LAVATORY

LVL

MAN

MCW

MFR

MO

MOT

MLDG

MATL

MAX

MECH

MT

MTL

MLP

MISC

MR

NA

NIC

NTS

NO

OD

OPP

OH

PCT

PC

PF

PFB

PMF

PLYWD

PIP

PP

PCLN

PT

PTD

QT

RAF

REINF

RFM

RO

RM

RTU

LEVEL

MANUAL OPERATION

METAL CLAD WOOD

MANUFACTURER

MASONRY OPENING

MOTOR OPERATOR

MOULDING

MATERIAL

MAXIMUM

MECHANICAL

MARBLE THRESHOLD

METAL

METAL LINER PANEL

MISCELLANEOUS

MOISTURE RESISTANT

NOT APPLICABLE

NOT IN CONTRACT

NOT TO SCALE

NUMBER

OUTSIDE DIAMETER

OPPOSITE

OPPOSITE HAND

PERCENT

PRECAST

PREFINISHED

PREFABRICATED

PRE-MOLDED FILLER

PLYWOOD

POURED IN PLACE

PRIME PAINTED

PORCELAIN TILE

PRESSURE TREATED

PAINTED

QUARRY TILE

RAISED ACCESS FLOOR

REINFORCING

RECESSED FLOOR MAT

ROUGH OPENING

ROOM

ROOF TOP UNIT

SC

SG

SHT

SEC

SIM

SPEC

SCW

SQ

SPF

SS

STL

SUSP

SF

TB

TBD

TGL

THML

TFF

THK

T&G

TOC

TOM

TOS

TD

T

TT

UL

VB

VCT

VERT

VLC

VS

VTR

VWC

WGL

WWF

WIN

W/ W/O

WD

SEALED CONCRETE

STEEL GRATE

SHEET

SECTION

SIMILAR

SPECIFICATION

SOLID CORE WOOD

SQUARE

STAIN (PREFINISHED)

STAINLESS STEEL

STEEL

SUSPENDED

SQUARE FEET

TERRAZZO BASE

TO BE DETERMINED

TEMPERED GLASS

THERMAL BREAK

TOP OF FINISHED FLOOR

THICK

TONGUE AND GROOVE

TOP OF CONCRETE

TOP OF MASONRY

TOP OF STEEL

TRENCH DRAIN

TROWEL

TERAZZO TILE

UNDERWRITERS LAB.

VINYL BASE

VINYL COMPOSITION TILE

VERTICAL

VINYL LAY-IN CEILING

VINYL SHEET

VENT THROUGH ROOF

VINYL WALL COVERING

WIRE GLASS LITE

WELDED FIRE FABRIC

WINDOW

WITH

WITHOUT

WOOD

ARCHITECT'S PROJECT NUMBER: 26015

ISSUE DATE: 17 SEPTEMBER 2026

DRAWING

NO. TITLE

DATE

RELEASED

RELEASE

GENERAL

DRAWING

NO. TITLE

DATE

RELEASED

RELEASE

CIVIL

DRAWING

NO. TITLE

DATE

RELEASED

RELEASE

STRUCTURAL

DRAWING

NO. TITLE

DATE

RELEASED

RELEASE

ARCHITECTURAL

CDBG TOWNSHIP BUILDING ADA

IMPROVEMENT PROJECT - PHASE 3

PINE GROVE TOWNSHIP

175 OAK GROVE ROAD, PINE GROVE, PA 17963

DRAWING

NO. TITLE

DATE

RELEASED

RELEASE

MECHANICAL / ELECTRICAL

EXISTING

BUILDING SITE

NOT APPLICABLE IN PHASE 3

PINE GROVE TOWNSHIP

OWNER

SCHUYLKILL COUNTY

401 N 2nd Street Pottsville, PA 17901

Ron Zimmerman Grant Manager rzimmerman@schuylkillcounty.pa.gov Office Phone: 570-628-1208

Cheryl Fuss Assistant Coordinator / Compliance Officer cfuss@schuylkillcounty.pa.gov Office Phone: 570-628-1206

GRANT ADMINISTRATOR

MEP0.0 MECHANICAL, ELECTRICAL & PLUMBING

INFORMATION SHEET

05/29/2026 ISSUED FOR

CONSTRUCTION

MEP1.0 MECHANICAL, ELECTRICAL & PLUMBING FLOOR

PLANS

05/29/2026 ISSUED FOR

CONSTRUCTION

MEP2.0 MECHANICAL, ELECTRICAL & PLUMBING

SPECIFICATIONS

05/29/2026 ISSUED FOR

CONSTRUCTION

A-101 NEW LOBBY TRANSACTION COUNTER FLOOR PLAN

- PHASE 3

09/17/2026 ISSUED FOR

CONSTRUCTION

A-102 TOILET PLANS, NOTES & INTERIOR ELEVAIONS -

PHASE 3

09/17/2026 ISSUED FOR

CONSTRUCTION

3/16" = 1'-0"1

EXISTING FIRST FLOOR PLAN - PHASE 3

A-001 COVER AND DATA SHEET - PHASE 3 09/17/2026 ISSUED FOR

CONSTRUCTION

No. Description Date

1 ISSUED FOR CONSTRUCTION 09-17-2026

C-101 GENERAL NOTES 09/17/2026 ISSUED FOR

CONSTRUCTION

C-102 SIDEWALK DETAILS 09/17/2026 ISSUED FOR

CONSTRUCTION

C-103 E&S NOTES 09/17/2026 ISSUED FOR

CONSTRUCTION

C-104 E&S DETAILS 09/17/2026 ISSUED FOR

CONSTRUCTION

E

N

N S Y L V

A

N

I A

C O

M

M O

NW EALT

H

O

F

REGISTERED

PROFESSIONAL

ENGINEER

PE077612

JAMES STEVEN TOHILL

Sheet No.:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Pine Grove Township, Schuylkill County, Pennsylvania

ADA IMPROVEMENT PROJECT - PHASE III

CDBG TOWNSHIP BUILDING

PINE GROVE TOWNSHIP

9/17/2026 0326-609043.26

$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$

CONC M

ON

BM 101

CONC M

ON

SAN C

O

I PIN

(FND)

GV

SAN C

O

MIN

ICIP

AL BLDG

PINE GROVE TWP

PARKINGHANDICAP

PARKINGHANDICAP

PARKINGHANDICAP

PILL

AR

PILL

AR

BM "A

ELEV=605

.09'LIGHT POLEMAG SP

IKE SET IN

BM "A

0-S4

W/U

G

PPL

POST

LIGHT

POST

LIGHT

LIGHT

FLOOD

BOX

DROP

ELEV=608

.44

FINI

SHED FL

OOR

ELEV=608

.42'

FINI

SHED FL

OOR

ELEV=599

.66'

FINI

SHED FL

OOR

ELEV=599

.64'FINI

SHED FL

OOR

CONC W

ALK

CONC WALK

TANK

PROPANE

TANK

PROPANE

WALL

TIMBER

BARRIER

MUNICI

PAL BLDG

PINE GROVE TWP

LOT

BIT

PARKING

UNIT

AC

UNIT

HEAT/AC

GENERATOR

CP NO 1

WALK

PAVER

FLAG POLE

CP NO 2

CP NO 3

GENERAL NOTES

AND (3) TO AVOID ALL UNNECESSARY CONFLICTS THEREWITH.

OWNERS INDEPENDENTLY, (2) TO DETERMINE THE EXACT LOCATION OF ALL UNDERGROUND UTILITIES PRIOR TO EXCAVATION OR DEMOLITION

CONTRACTOR IS RESPONSIBLE AT ITS SOLE COST AND EXPENSE AND WITHOUT RELIANCE ON THESE PLANS: (1) TO CONTACT ALL UTILITY

UNDERGROUND UTILITIES IS FOR GENERAL INFORMATION AND GUIDANCE ONLY, AND IS NOT GUARANTEED TO BE COMPLETE OR ACCURATE.

NOTE: INFORMATION ON THESE PLANS CONCERNING THE CONDITIONS, DIMENSIONS, DEPTH, SIZE, LOCATION OR ANY OTHER FEATURE OF

SURFACE INFORMATION IS INDICATED ON THE DRAWINGS.

ALL UNDERGROUND INSTALLATION OR STRUCTURES ARE SHOWN ON THE PLANS. NO FIELD EXCAVATION HAS BEEN PERFORMED. AVAILABLE

ACCURACY OF THE LOCATION OF THE PRESENT UNDERGROUND UTILITY INSTALLATION OR STRUCTURES SHOWN ON THE PLANS, OR THAT

BENESCH FROM THE UTILITIES LISTED ABOVE. BENESCH DOES NOT GUARANTEE, REPRESENT, WARRANT OR ASSURE EITHER THE

WARNING! EXISTING UTILITIES, AS SHOWN ON THESE DRAWINGS, ARE IN ACCORDANCE WITH INFORMATION THAT HAS BEEN PROVIDED TO

AARON.RITTENBAUGH@OUTLOOK.COM

ATTN: AARON RITTENBAUGH

PINE GROVE, PA 17963

235 SUDEBURG RD

PINE GROVE JOINT TREATMENT AUTHORITY

DLHAUPT@PPLWEB.COM

ATTN: DOUG HAUPT

PAXINOS, PA 17860

437 BLUE CHURCH RD

PPL ELECTRIC UTILITIES CORPORATION

MADAMS@FIRSTENERGYCORP.COM

ATTN: MELLYSSA ADAMS

AKRON, OH. 44320

341 WHITE POND DR

METROPOLITAN EDISON CO/FIRST ENERGY CORPORATION

LIST OF UTILITIES:

PURPLE - NON-POTABLE WATER, IRRIGATION OR SLURRY LINES

WHITE - PROPOSED EXCAVATION

GREEN - SEWERS AND DRAIN LINES

BLUE - POTABLE WATER

ORANGE - COMMUNICATION, ALARM OR SIGNAL LINES, CABLES OR CONDUIT

YELLOW - GAS, OIL, STEAM, PETROLEUM OR GASEOUS MATERIALS

RED - ELECTRIC POWER LINES, CABLES, CONDUIT AND LIGHTING CODES

COLOR CODES. KNOW THEM!

ACT NO. 287 OF 1974 AS AMENDED STANDARDIZES THE COLOR-MARKING OF UNDERGROUND UTILITIES IN ACCORDANCE WITH UNIFORM

SERIAL NO.: 20261942896

THIS PROJECT HAS A SERIAL NUMBER REGISTERED WITH THE ONE CALL SYSTEM, INC. USE IT!

GENERAL NOTES

KEY MAP

REMOVE EXISTING PAVERS

SEE SHEET C-102 FOR MORE DETAIL

INSTALL ADA SIDEWALK TO EXISTING MAILBOX

C-101

OF PENNSYLVANIA.

THAN 90 WORKING DAYS NOTICE WHEN ENGAGED IN THE DESIGN PHASE. THESE REQUIREMENTS APPLY ANYWHERE IN THE COMMONWEALTH

RIP, SCRAPE, TRENCH, TUNNEL OR DEMOLISH. ACT NO. 187 REQUIRES DESIGNERS TO GIVE NO LESS THAN 10 WORKING DAYS NOR MORE

EARTH (WITH OR WITHOUT EXPLOSIVES), ANCHOR, AUGER, BACKFILL, BLAST, BORE, DIG, DITCH, DRILL, DRIVE-IN, GRADE, PLOW-IN, PULL-IN, DAYS NOTICE NOR MORE THAN 10 WORKING DAYS NOTICE FROM EXCAVATORS/DEMOLITION CONTRACTORS WHO ARE ABOUT TO MOVE

PENNSYLVANIA ACT NO. 287 OF 1974 AS AMENDED, THE UNDERGROUND UTILITY LINE PROTECTION LAW, REQUIRES NO LESS THAN 3 WORKING

1-800-242-1776

PENNSYLVANIA ONE CALL SYSTEM, INC.

STOP-CALL BEFORE YOU DIG!

THROUGHOUT THE PROJECT AREA.

CONTRACTOR SHALL BE MADE AWARE THAT LOW LYING OVERHEAD UTILITY LINES (POWER, TELEPHONE, CABLE TV, ETC.) MAY EXIST

UNDERGROUND UTILITIES IS ON THE CONTRACTOR AND NOT ON THE PROJECT OWNER, BENESCH, OR THEIR REPRESENTATIVES.

THE RISK OF FINANCIAL LOSS RESULTING FROM MISIDENTIFICATION, MISLOCATION OR MISUNDERSTANDING OF THE LOCATION OF THE

DAMAGE HAS OCCURRED.

THE CONTRACTOR SHALL REPAIR DAMAGED SEWER LATERALS AND/OR WATER SERVICE LINES WITHIN THE SAME WORKING DAY THAT THE

ALL SHORING FOR TRENCHES WILL BE IN ACCORDANCE WITH OSHA STANDARDS AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.

SEDIMENTATION CONTROL MANUAL" AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.

CONSTRUCTION. SEE SEDIMENT AND EROSION CONTROL NOTES AND DETAILS. ALL CONTROLS SHALL CONFORM TO "EROSION AND

ALL REQUIRED SOIL EROSION AND SEDIMENTATION CONTROLS SHALL BE PROVIDED, INSTALLED AND MAINTAINED DURING ALL PHASES OF

AMERICAN VERTICAL DATUM OF 1988.

HORIZONTAL CONTROL IS BASED ON PA STATE PLANE COORDINATE SYSTEM (SOUTH ZONE) NAD83. VERTICAL CONTROL IS BASED ON NORTH

RIGHT-OF-WAY FOR TOWNSHIP ROADWAYS ARE RECORDED FROM SCHUYLKILL COUNTY TAX MAPS AND ARE APPROXIMATE.

TO ANY WORK.

EXCEPT WHERE SPECIFICALLY SHOWN. CHANGES TO LIMIT OF WORK BY THE CONTRACTOR MUST BE APPROVED BY THE ENGINEER PRIOR

MATCH PROPOSED PAVING ELEVATION TO EXISTING PAVING ELEVATIONS WHEREVER THEY ADJOIN. LIMIT OF WORK SHOWN IS APPROXIMATE

AND SHALL BE INCIDENTAL TO ALL OTHER ITEMS OF WORK.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL STAKEOUTS BASED ON THE CONTRACT DRAWINGS AND SPECIFICATIONS

PROPER EXCAVATION SUPPORT SYSTEMS, BACKFILL, COVER, OR FENCE TO PROTECT EXCAVATION AREAS DURING NON-WORKING HOURS.

THIS PROJECT IS SUBJECT TO INSPECTION BY THE ENGINEER AND APPLICABLE CODE ENFORCEMENT AGENCIES. CONTRACTOR SHALL USE

THE OWNER RESERVES THE RIGHT TO ELIMINATE ANY OR ALL OF THIS WORK.

PUBLICATION 408 IN ITS LATEST REVISION.

PENNDOT SPECIFICATIONS SHALL MEAN COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION SPECIFICATIONS

CONSTRUCTION TO PREVENT DAMAGE TO PIPES AND APPURTENANCES.

IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT THERE IS SUFFICIENT COVER ON EXISTING PIPING DURING

PLAN LOCATIONS AND DIMENSIONS SHALL BE STRICTLY ADHERED TO UNLESS OTHERWISE DIRECTED BY THE OWNER OR THE ENGINEER.

THAT ALL SUBSURFACE STRUCTURES ARE SHOWN.

RESPONSIBILITY TO VERIFY AND ALLOW FOR THEIR LOCATIONS AND PROVIDE FOR THEIR PROTECTION. THE OWNER DOES NOT GUARANTEE

EXISTING UTILITIES ARE SHOWN IN ACCORDANCE WITH THE BEST AVAILABLE INFORMATION. IT SHALL BE THE CONTRACTOR'S

THE CONTRACTOR SHALL COORDINATE ALL WORK WITH UTILITY COMPANIES INVOLVED.

DIRECTED BY THE ENGINEER AT NO ADDITIONAL COST TO THE OWNER.

ALL AREAS DISTURBED OUTSIDE THE LIMITS OF CONSTRUCTION SHALL BE REPAIRED OR REPLACED TO THEIR ORIGINAL CONDITION AS

PRIOR TO CONSTRUCTION ACTIVITIES. ANY DISCREPENCIES SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ENGINEER.

ALL DIMENSIONS, EXISTING CONDITIONS AND PROPOSED QUANTITIES SHALL BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR

CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS AND PAY THE REQUIRED FEE.

THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS APPLICABLE TO CONSTRUCTION OF THIS SITE. THE

RESTORE AREA AROUND CONSTRUCTION

SEE ARCHITECTURAL PLANS FOR INTERIOR IMPROVEMENTS

POINT

CONTROL

TYPE ELEV.

COORDINATES

NORTH EAST

CP NO.1 MAG NAIL 604.77' 447726.93 2340388.73

2340263.19447657.40607.38'MAG NAILCP NO.2

CP NO.3 MAG NAIL 598.12' 447598.07 2340359.78

SURVEY TRAVERSE CONTROL POINT COORDINATES

GENERAL NOTES

SIDEWALK DETAILS

DESCRIPTION SHEET

C-102

C-103

C-104

C-101

E&S DETAILS

E&S NOTES

SHEET INDEX

0 200100 FEET

N

N S Y L V

A

N

I A

C O

M

M O

REGISTERED

PROFESSIONAL

ENGINEER

PE077612

JAMES STEVEN TOHILL

Sheet No.:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Pine Grove Township, Schuylkill County, Pennsylvania

ADA IMPROVEMENT PROJECT - PHASE III

CDBG TOWNSHIP BUILDING

PINE GROVE TOWNSHIP

9/17/2026 0326-609043.26

$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$

POINT NOTES

ME

ME

ME

LEGEND

MAILBOX SIDEWALK

NORTHING EASTING TS ELEV

A1

2340313.09447677.28

2340306.46447678.09

2340303.11447691.85

2340297.55447714.68

2340296.37447719.54

2340301.22447720.72

6.72'

0.45%

.2

.4

EXISTING MAILBOX TO REMAIN

4" SUBBASE

ITEM QUANTITY

TOPSOIL/SEEDING/MULCH

4" CONCRETE

19 SY

31 SY

31 SY

- LAWN RESTORATION

- PROPOSED CONCRETE SURFACE

- POINT & REFERENCE NUMBER

SIDEWALK DETAILS

A12

A11

A10

A9

A8

A7

A6

A5

A4

A3

A2

A1

ME

607.602340309.14447688.19

2340310.01447690.42

2340316.77447687.93

2340304.29447686.69

MAILBOX SIDEWALK SLOPES & ELEVATION DETAIL

ESTIMATE OF QUANTITIES (FOR INFORMATION ONLY)

REMOVE EXISTING PAVERS

EXISTING SIDEWALK

A2

A9

C-102

.1

.5

7.21'

1.80%

.2

5'

0.60%

5'

1.80%

447715.86

447693.03

2340302.41

2340307.96

607.60

607.47

607.63

607.60

607.55

607.53

607.47

607.46

607.37

607.44

607.50

5.00'

0.60%

NTS

SUBGRADE

PROOF ROLL

TO CONSTRUCTION)

PROCTOR (EXCAVATION INCIDENTAL

AND ROLLED TO 97% STANDARD

4" NO. 2A STONE COMPACTED

THE INSPECTOR-IN-CHARGE PRIOR TO CONCRETE PLACEMENT.

SUFFFICIENT LONGITUDINAL SLOPE. THESE LOCATIONS SHALL BE APPROVED BY

SIDEWALK CROSS SLOPE MAY BE 0% IN ISOLATED LOCATIONS WHICH HAVE 3.

DEPTH (TYP)

TOPSOIL AND SEED DISTURBED AREAS AS NECESSARY. MINIMUM 4" TOPSOIL 2.

CONSTRUCTION OF SIDEWALK.

RANGE SHALL BE REPORTED TO THE INSPECTOR IN CHARGE PRIOR TO

AND 2% MAXIMUM TOWARD CURB. ANY SIDEWALK AREAS THAT DO NOT MEET THIS

A 4'-0" (MIN) SIDEWALK ACCESSIBLE ROUTE SHALL SLOPE 0.5% MINIMUM 1.

NOTES:

SCORED JOINTS AT 5'-0" O.C.

20'-0" MAXIMUM

½" PREMOLDED EXPANSION MATERIAL AT

VARIABLE WIDTH - SEE DETAIL

GROUND

EXISTING

ACCESS PATH DETAIL

A1

A12

A3

A4

A11

A10

A8

A7

A6

A5

EXISTING SIDEWALK

EXPANSION JOINT

REPLACE TO EXISTING

EXPANSION JOINT

REPLACE TO EXISTING

.8

.0

.0

.4

.0

.0

5.00'

1.00%

.5

.2

.5

.2

ME = MATCH EXISTING

TS ELEV = TOP OF SIDEWALK ELEVATION

4" CONCRETE CLASS AAA

.4

EXISTING PAVER REMOVAL 9 SY

½" = 1'-0"

1 0 1 2 FEET

½" = 1'-0"

1 0 1 2 FEET

N

N S Y L V

A

N

I A

C O

M

M O

REGISTERED

PROFESSIONAL

ENGINEER

PE077612

JAMES STEVEN TOHILL

Sheet No.:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Pine Grove Township, Schuylkill County, Pennsylvania

ADA IMPROVEMENT PROJECT - PHASE III

CDBG TOWNSHIP BUILDING

PINE GROVE TOWNSHIP

9/17/2026 0326-609043.26

$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$

E&S NOTES

C-103

EROSION CONTROL POLICIES AND MAINTENNANCE PROGRAM

$25,000 IN MISDEMEANOR CRIMINAL PENALTIES FOR EACH VIOLATION.

UP TO $10,000 PER DAY IN CIVIL PENALTIES, UP TO $10,000 IN SUMMARY CRIMINAL PENALTIES, AND UP TO

DEFINED IN SECTION 602 OF THE PENNSYLVANIA CLEAN STREAMS LAW. THE CLEAN STREAMS LAW PROVIDES FOR

MAY RESULT IN ADMINISTRATIVE, CIVIL, AND/OR CRIMINAL PENALTIES BEING INSTITUTED BY THE DEPARTMENT AS

CONSTRUCTION SITE, OR FAILURE TO TAKE IMMEDIATE CORRECTIVE ACTION TO RESOLVE FAILURE OF E&S BMPS

FAILURE TO CORRECTLY INSTALL E&S BMPS, FAILURE TO PREVENT SEDIMENT-LADEN RUNOFF FROM LEAVING THE 31.

GERMINATING SEASON.

RAPID REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE ONLY DURING THE

DURING REMOVAL OR CONVERSION OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO ENSURE

CONVERTED TO PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS DISTURBED

AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY E&S BMPS MUST BE REMOVED OR 30.

INSPECTION PRIOR TO REMOVAL/CONVERSION OF THE E&S BMPS.

AREAS, THE OWNER AND/OR OPERATOR SHALL CONTACT THE LOCAL CONSERVATION DISTRICT OR PADEP FOR AN

UPON COMPLETION OF ALL EARTH DISTURBANCE ACTIVITIES AND PERMANENT STABILIZATION OF ALL DISTURBED 29.

STABILIZED OR UNTIL THEY ARE REPLACED BY ANOTHER BMP APPROVED BY THE COUNTY.

E&S BMPS MUST REMAIN FUNCTIONAL AS SUCH UNTIL ALL AREAS TRIBUTARY TO THEM ARE PERMANENTLY 28.

FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.

PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND

PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER 27.

STABILIZED IN ACCORDANCE WITH THE PERMANENT STABILIZATION SPECIFICATIONS.

STABILIZATION SPECIFICATIONS. THOSE AREAS WHICH WILL NOT BE REACTIVATED WITHIN 1 YEAR SHALL BE

WHICH WILL BE REACTIVATED WITHIN 1 YEAR, MAY BE STABILIZED IN ACCORDANCE WITH THE TEMPORARY

PROTECTIVE BLANKETING SHALL BE APPLIED AS DESCRIBED IN THE PLAN. AREAS NOT AT FINISHED GRADE, OPERATOR SHALL STABILIZE ALL DISTURBED AREAS. DURING NON-GERMINATING MONTHS, MULCH OR

IMMEDIATELY AFTER EARTH DISTURBANCE ACTIVITIES CEASE IN ANY AREA OR SUBAREA OF THE PROJECT, THE 26.

THE STANDARDS OF THIS PLAN.

A SURFACE WATER, OR AS OTHERWISE SHOWN ON THE PLAN DRAWINGS, SHALL BE BLANKETED ACCORDING TO

SLOPES IN COMPETENT BEDROCK AND ROCK FILLS NEED NOT BE VEGETATED. SEEDED AREAS WITHIN 50 FEET OF

ALL GRADED AREAS SHALL BE PERMANENTLY STABILIZED IMMEDIATELY UPON REACHING FINISHED GRADE. CUT 25.

STANDARD SPECIFICATION FOR SUBSURFACE DRAIN OR OTHER APPROVED METHOD.

SEEPS OR SPRINGS ENCOUNTERED DURING CONSTRUCTION SHALL BE HANDLED IN ACCORDANCE WITH THE 24.

FILLS SHALL NOT BE PLACED ON SATURATED OR FROZEN SURFACES.23.

FILLS.

FROZEN MATERIALS OR SOFT, MUCKY, OR HIGHLY COMPRESSIBLE MATERIALS SHALL NOT BE INCORPORATED INTO 22.

OBJECTIONABLE MATERIALS THAT WOULD INTERFERE WITH OR PREVENT CONSTRUCTION OF SATISFACTORY FILLS.

FILL MATERIALS SHALL BE FREE OF FROZEN PARTICLES, BRUSH, ROOTS, SOD, OR OTHER FOREIGN OR 21.

ALL EARTHEN FILLS SHALL BE PLACED IN COMPACTED LAYERS NOT TO EXCEED 9 INCHES IN THICKNESS.20.

BE COMPACTED IN ACCORDANCE WITH LOCAL REQUIREMENTS OR CODES.

OTHER RELATED PROBLEMS. FILL INTENDED TO SUPPORT BUILDINGS, STRUCTURES AND CONDUITS, ETC. SHALL

ALL FILLS SHALL BE COMPACTED AS REQUIRED TO REDUCE EROSION, SLIPPAGE, SETTLEMENT, SUBSIDENCE OR 19.

MINIMUM OF 2 INCHES OF TOPSOIL.

MINIMUM 4 INCHES OF TOPSOIL IN PLACE PRIOR TO SEEDING AND MULCHING. FILL OUTSLOPES SHALL HAVE A

INCHES ON COMPACTED SOILS - PRIOR TO PLACEMENT OF TOPSOIL. AREAS TO BE VEGETATED SHALL HAVE A

AREAS WHICH ARE TO BE TOPSOILED SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 3 TO 5 INCHES - 6 TO 12 18.

DRAWINGS.

ALL SEDIMENT REMOVED FROM BMPS SHALL BE DISPOSED OF IN THE MANNER DESCRIBED ON THE PLAN 17.

SURFACE WATER.

SHALL THE SEDIMENT BE WASHED, SHOVELED, OR SWEPT INTO ANY ROADSIDE DITCH, STORM SEWER, OR

SITE BY THE END OF EACH WORK DAY AND DISPOSED IN THE MANNER DESCRIBED IN THIS PLAN. IN NO CASE

SEDIMENT TRACKED ONTO ANY PUBLIC ROADWAY OR SIDEWALK SHALL BE RETURNED TO THE CONSTRUCTION 16.

OFFICIALS AT THE TIME OF INSPECTION.

THEY WERE CORRECTED SHALL BE MAINTAINED ON THE SITE AND BE MADE AVAILABLE TO REGULATORY AGENCY

A LOG SHOWING DATES THAT E&S BMPS WERE INSPECTED AS WELL AS ANY DEFICIENCIES FOUND AND THE DATE 15.

REPLACEMENT BMPS, OR MODIFICATIONS OF THOSE INSTALLED WILL BE REQUIRED.

REMULCHING AND RENETTING MUST BE PERFORMED IMMEDIATELY. IF E&S BMPS FAIL TO PERFORM AS EXPECTED, REMEDIAL MAINTENANCE WORK, INCLUDING CLEAN OUT, REPAIR, REPLACEMENT, REGRADING, RESEEDING, INSPECTIONS OF ALL E&S BMPS AFTER EACH RUNOFF EVENT AND ON A WEEKLY BASIS. ALL PREVENTATIVE AND

UNTIL THE SITE IS STABILIZED, ALL E&S BMPS MUST BE MAINTAINED PROPERLY. MAINTENANCE MUST INCLUDE 14.

NOT BE DISTURBED IN 4 DAYS.

THE CONTRACTOR MUST IMPLEMENT TEMPORARY STABILIZATION MEASURES IN ANY DISTURBED AREA THAT WILL 13.

THIS PLAN, OVER UNDISTURBED VEGETATED AREAS.

ALL PUMPING OF WATER FROM ANY WORK AREA SHALL BE DONE ACCORDING TO THE PROCEDURE DESCRIBED IN 12.

OF A REGULATED SUBSTANCE BUT QUALIFYING AS CLEAN FILL DUE TO ANALYTICAL TESTING.

FP-001 MUST BE RETAINED BY THE PROPERTY OWNER FOR ANY FILL MATERIAL AFFECTED BY A SPILL OR RELEASE

THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ANY MATERIAL BROUGHT ON SITE IS CLEAN FILL. FORM 11.

PRIOR TO BEING ACTIVATED.

ALL OFF-SITE WASTE AND BORROW AREAS MUST HAVE AN E&S PLAN APPROVED BY PADEP FULLY IMPLEMENTED 10.

BURNED, BURIED, DUMPED, OR DISCHARGED AT THE SITE.

SEQ., 271.1, AND 287.1 ET. SEQ. NO BUILDING MATERIALS, WASTES, OR UNUSED BUILDING MATERIALS SHALL BE

ACCORDANCE WITH THE DEPARTMENT'S SOLID WASTE MANAGEMENT REGULATIONS AT 25 PA. CODE 260.1 ET

ALL BUILDING MATERIALS AND WASTES MUST BE REMOVED FROM THE SITE AND RECYCLED OR DISPOSED OF IN 9.

THE REGIONAL OFFICE OF THE DEPARTMENT.

POTENTIAL FOR EROSION AND SEDIMENT POLLUTION AND NOTIFY THE LOCAL CONSERVATION DISTRICT AND/OR

EROSION AND/OR SEDIMENT POLLUTION, THE OPERATOR SHALL IMPLEMENT APPROPRIATE BMPS TO MINIMIZE THE

IMMEDIATELY UPON DISCOVERING UNFORESEEN CIRCUMSTANCES POSING THE POTENTIAL FOR ACCELERATED 8.

2H:1V OR FLATTER.

SHOWN ON THE PLAN DRAWINGS. STOCKPILE HEIGHTS MUST NOT EXCEED 35 FEET. STOCKPILE SLOPES MUST BE

AREAS THAT ARE TO BE STABILIZED BY VEGETATION. EACH STOCKPILE SHALL BE PROTECTED IN THE MANNER

APPROVED BY THE TOWNSHIP IN THE AMOUNT NECESSARY TO COMPLETE THE FINISH GRADING OF ALL EXPOSED

TOPSOIL REQUIRED FOR THE ESTABLISHMENT OF VEGETATION SHALL BE STOCKPILED AT THE LOCATION 7.

DESCRIBED IN THIS E&S PLAN.

SPECIFIED BY THE BMP SEQUENCE FOR THAT STAGE OR PHASE HAVE BEEN INSTALLED AND ARE FUNCTIONING AS

COMMENCE IN ANY STAGE OR PHASE OF THE PROJECT UNTIL THE E&S BEST MANAGEMENT PRACTICES (BMPS)

OF THE CONSTRUCTION SEQUENCE. GENERAL SITE CLEARING, GRUBBING AND TOPSOIL STRIPPING MAY NOT

CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED TO THOSE AREAS DESCRIBED IN EACH STAGE 6.

VEGETATION, ROOTS AND OTHER OBJECTIONABLE MATERIAL.

AREAS TO BE FILLED SHOULD BE CLEARED, GRUBBED, AND STRIPPED OF TOPSOIL TO REMOVE TREES, 5.

TO IMPLEMENTATION.

PLAN DRAWINGS. DEVIATION FROM THAT SEQUENCE MUST BE APPROVED IN WRITING FROM THE COUNTY PRIOR

ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE SEQUENCE PROVIDED ON THE 4.

THE LOCATION OF EXISTING UNDERGROUND UTILITIES.

PREVIOUSLY UNMARKED, THE PENNSYLVANIA ONE CALL SYSTEM INC. SHALL BE NOTIFIED AT 1-800-242-1776 FOR

AT LEAST 3 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, OR EXPANDING INTO AN AREA 3.

MUNICIPAL OFFICIALS AND THE E&S PLAN PREPARER TO AN ON-SITE PRECONSTRUCTION MEETING.

GRUBBING, THE OWNER AND/OR OPERATOR SHALL INVITE ALL CONTRACTORS, THE LANDOWNER, APPROPRIATE

AT LEAST 7 DAYS PRIOR TO STARTING ANY EARTH DISTURBANCE ACTIVITIES, INCLUDING CLEARING AND 2.

THOSE CHANGES FOR REVIEW AND APPROVAL AT ITS DISCRETION.

PLAN PRIOR TO IMPLEMENTATION OF THOSE CHANGES. THE OWNER MAY REQUIRE A WRITTEN SUBMITTAL OF

BE AVAILABLE AT THE PROJECT SITE AT ALL TIMES. THE OWNER SHALL BE NOTIFIED OF ANY CHANGES TO THE

ACCORDANCE WITH THE EROSION AND SEDIMENTATION CONTROL (E&S) PLAN. A COPY OF THE DRAWINGS MUST

ALL EARTH DISTURBANCES, INCLUDING CLEARING AND GRUBBING AS WELL AS CUTS AND FILL SHALL BE DONE IN 1.

DEPARTMENT OF ENVIRONMENTAL PROTECTION AND THE ENGINEERS REPRESENTATIVE:

FOLLOWING GUIDELINES AS THEY ARE APPLICABLE AND IN ACCORDANCE TO THE INSTRUCTIONS OF THE

CONTROL EROSION, IT IS REQUIRED THAT THE CONTRACTOR FOR THIS PROJECT CONFORMS WITH THE

IN ACCORDANCE WITH THE CURRENT POLICIES AND PRACTICES IN THE COMMONWEALTH OF PENNSYLVANIA TO

DURING THE GERMINATING SEASON.

ENSURE RAPID REVEGETATION OF DISTURBED AREAS, SUCH REMOVAL/CONVERSIONS SHOULD BE DONE ONLY

DISTURBED DURING REMOVAL OR CONVERSION OF THE BMPS SHALL BE STABILIZED IMMEDIATELY. IN ORDER TO

REMOVED OR CONVERTED TO PERMANENT POST CONSTRUCTION STORMWATER MANAGEMENT BMPS. AREAS

AFTER FINAL SITE STABILIZATION HAS BEEN ACHIEVED, TEMPORARY EROSION AND SEDIMENT BMPS MUST BE 11.

FILL SLOPES SHALL BE CAPABLE OF RESISTING FAILURE DUE TO SLUMPING, SLIDING, OR OTHER MOVEMENTS.

PERMANENT NON-VEGETATIVE COVER WITH A DENSITY SUFFICIENT TO RESIST ACCELERATED EROSION. CUT AND

PERMANENT STABILIZATION IS DEFINED AS A MINIMUM UNIFORM, PERENNIAL 70% VEGETATIVE COVER OR OTHER 10.

REMOVE TRAFFIC CONTROL DEVICES. 9.

STABILIZE ALL REMAINING DISTURBED AREAS.8.

SUBBASE PRIOR TO A FORECASTED SIGNIFICANT RAINFALL EVENT.

EXCAVATE AND CONSTRUCT SIDEWALK ADDITION. IN NO CASE SHALL AN AREA EXCAVATED BE WITHOUT STONE 7.

INSTALL REQUIRED TRAFFIC CONTROL DEVICES. 6.

COMPOST FILTER SOCK.

CONTROL SEDIMENT DURING THESE OPERATIONS. TEMPORARY CONTROLS INCLUDE CONCRETE WASHOUT, PRIOR TO THE START OF GRUBBING AND EXCAVATION, PLACE TEMPORARY EROSION CONTROL FEATURES TO 5.

AND ARE FUNCTIONING AS DESCRIBED IN THIS DOCUMENT.

TOPSOIL STRIPPING UNTIL THE E&S BMPS SPECIFIED BY THE CONSTRUCTION SEQUENCE HAVE BEEN INSTALLED

DESCRIBED IN THE CONSTRUCTION SEQUENCE. DO NOT COMMENCE GENERAL SITE CLEARING, GRUBBING AND

CLEAR THE SITE AS REQUIRED. LIMIT CLEARING, GRUBBING, AND TOPSOIL STRIPPING TO THOSE AREAS 4.

UTILITIES.

ACTIVITIES SHOULD NOTIFY THE PENNSYLVANIA ONE-CALL SYSTEM, INC. AT 1-800-242-1776 TO LOCATE BURIED

LEAST 3 DAYS BEFORE STARTING ANY EARTH DISTURBING ACTIVITIES, ALL CONTRACTORS INVOLVED IN THOSE

PLAN PREPARER, A REPRESENTATIVE OF THE COUNTY, FOR AN ON-SITE RECONSTRUCTION MEETING. ALSO, AT

INVITE ALL CONTRACTORS INVOLVED IN THOSE ACTIVITIES, THE EROSION AND SEDIMENT POLLUTION CONTROL

AT LEAST 7 DAYS BEFORE STARTING ANY EARTH DISTURBANCE ACTIVITIES, THE GENERAL CONTRACTOR SHALL 3.

CLEARING, GRUBBING, AND TOPSOIL STRIPPING SHALL BE LIMITED ONLY TO THOSE AREAS IN EACH STAGE.

STAGE SHALL BE COMPLETED AND IMMEDIATELY STABILIZED BEFORE ANY FOLLOWING STAGE IS INITIATED.

ALL EARTH DISTURBANCE ACTIVITIES SHALL PROCEED IN ACCORDANCE WITH THE FOLLOWING SEQUENCE. EACH 1.

CONSTRUCTION SEQUENCE

N

N S Y L V

A

N

I A

C O

M

M O

REGISTERED

PROFESSIONAL

ENGINEER

PE077612

JAMES STEVEN TOHILL

Sheet No.:

Rev Date By Chk'd Description

Scale: AS NOTED Date: Project No.:modification of this plan or design information, or any part thereof, is strictly prohibited, except by written permission of this firm.

Copyright 2026, of Benesch. All rights reserved. This plan and design content is the property of Benesch. Use, reuse, reproduction or

570-622-4055

Pottsville, Pennsylvania 17901

400 One Norwegian Plaza

Pine Grove Township, Schuylkill County, Pennsylvania

ADA IMPROVEMENT PROJECT - PHASE III

CDBG TOWNSHIP BUILDING

PINE GROVE TOWNSHIP

9/17/2026 0326-609043.26

$USERCFG$ $USER$ $DATE$ $TIME$ $FILE$

E&S DETAILS

C-104

(LB/ACRE)

LB/1000 SQ YD

SEEDING RATE

WEED SEED

MAX. %

GERMINATIONPURITY

MINIMUM %

FORMULA AND SPECIES

TABLE A

WEIGHT

% BY

FORMULA B RESIDENTIAL MIX:

VARIETY EXCEEDING 50% OF THE TOTAL BLUEGRASS COMPONENT.

COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE

KENTUCKY BLUEGRASS MIXTURE (POA PRATENSIS). A

OR SSP COMMUTATE) (IMPROVED AND CERTIFIED)

CREEPING RED FESCUE OR CHEWINGS FESCUE (FESTUCA RUBRA

VARIETY EXCEEDING 50% OF THE TOTAL RYEGRASS COMPONENT.

COMBINATION OF IMPROVED CERTIFIED VARIETIES WITH NO ONE

PERENNIAL RYEGRASS MIXTURE (LOLIUM PERENNE). A

0.15

0.10

0.10

21.0 (105)

12.5 (62.5)

8.5 (42.5)

42.0 (210) TOTAL

FORMULA T TEMPORARY GRASS MIX:

CEREAL RYE (SECALE CEREALE) (FALL)

OATS (AVENA SATIVA) (SPRING)

0.1

0.1

6 (30)

6 (30)

6 (30) TOTAL

*IF A SPECIES IS UNAVAILABLE IN THIS MIX, SUBSTITUTE BY INCREASING THE PERCENTAGE OF OTHER ITEMS IN THE MIX.

SEEDING SEASON DATES:

MULCHING RATE:

MULCH TYPE:

LIMING RATE:

FERTILIZER APPL RATE

FERTILIZER TYPE:

APPLICATION RATE:

% PURE LIVE SEED:

SPECIES:

/15 TO 6/1 & 8/1 TO 10/153

HAY

6.0

SEE TABLE A

FORMULA T TEMPORARY GRASS MIX(TEMPORARY)

LB/1000 SY

LB/1000 SY

LB/1000 SY

(X-X-X)

LB/1000 SY

SEEDING SEASON DATES:

ANCHORING METHOD:

RATE OF ANCHOR MATERIAL APPL:

ANCHOR MATERIAL:

MULCHING RATE:

MULCH TYPE:

LIMING RATE:

FERTILIZER APPL RATE

FERTILIZER TYPE:

APPLICATION RATE:

% PURE LIVE SEED:

SPECIES:(PERMANENT, <3:1 SLOPES)

LB/1000 SY

LB/1000 SY

LB/1000 SY

LB/1000 SY

LB/1000 SY

(X-X-X)

LB/1000 SY

/15 TO 6/1 & 8/1 TO 10/153

PER MANUFACTURERS' INSTRUCTIONS

STRAW

42.0

SEE TABLE A

FORMULA B RESIDENTIAL MIX

10-20-20

38-0-0 UREAFORM

59 TO 50 AS DIRECTED

32-0-0 TO 38-0-0 SULFER COATED UREA

31-0-0

10-20-20

38-0-0 UREAFORM

59 TO 50 AS DIRECTED

32-0-0 TO 38-0-0 SULFER COATED UREA

31-0-0

PER MANUFACTURERS' INSTRUCTIONS

POLYVINYL ACETATE

RECYCLED CELLULOSE FIBER/WOOD FIBER MIXTURE

RECYCLED CELLULOSE FIBER

WOOD FIBER

PER MANUFACTURERS' INSTRUCTIONS

NONASPHALTIC EMULSION

AND OROR

AND OR OR

ORAND

OR OR

SCHEDULE OF SEEING AND SOIL SUPPLEMENTS

TABLE B

T

B

FORMULA

TEMPORARY SEEDING

NON-STEEP, HIGHLY MAINTAINED SURFACES, LAWN

APPLICATION

NTS

SECTION VIEW

PLAN VIEW

AREA

UNDISTURBED

UNDISTURBED AREADISTURBED AREA

AREA

DISTURBED

M

IN

BLOWN / PLACED FILTER MEDIA COMPOST FILTER SOCK

2" x 2" WOODEN STAKES PLACED 10' OC

PLACED 10' OC (TYP)

2" x 2" WOODEN STAKES COMPOST FILTER SOCK

F L O

W F L O

W

CONTOURS

EXISTING

JOINING DETAIL

MIN

12"

STAKE

COMPOST FILTER SOCK

COMPOST SOCK FABRIC MINIMUM SPECIFICATIONS

TWO-PLY SYSTEMS

SOCK FABRICS COMPOSED OF BURLAP MAY BE USED ON PROJECTS LASTING 6 MONTHS OR LESS

MATERIAL TYPE

CHARACTERISTICS

MATERIAL

DIAMETERS

SOCK

MESH OPENING

STRENGTH

TENSILE

(ASTM-G-155)

STRENGTH

ORIGINAL

STABILITY %

ULTRAVIOLET

LONGEVITY

FUNCTIONAL

MINIMUM

3 MIL HDPE

DEGRADABLE

PHOTO-

18"

12"

3/8"

1000 HR

23% AT

6 MONTHS

5 MIL HDPE

DEGRADABLE

PHOTO-

32"

24"

18"

12"

3/8"

26 PSI

1000 HR

23% AT

9 MONTHS

5 MIL HDPE

DEGRADABLE

BIO-

32"

24"

18"

12"

3/8"

26 PSI

6 MONTHS

(MFPP)

POLYPROPYLENE

MULTI-FILAMENT

DEGRADABLE

PHOTO-

32"

24"

18"

12"

3/8"

44 PSI

1000 HR

100% AT

1 YEAR

(HDMFPP)

POLYPROPYLENE

MULTI-FILAMENT

HEAVY DUTY

DEGRADABLE

PHOTO-

32"

24"

18"

12"

1/8"

202 PSI

1000 HR

100% AT

2 YEARS

INNER CONTAINMENT NETTING

OUTER FILTRATION MESH

HDPE BIAXIAL NET

CONTINUOUSLY WOUND

FUSION-WELDED JUNCTURES

3/4" X 3/4" MAX APERTURE SIZE

MECHANICALLY FUSED VIA NEEDLE PUNCH)

(WOVEN LAYER AND NON-WOVEN FLEECE

COMPOSITE POLYPROPYLENE FABRIC

3 /16" MAX APERTURE SIZE

ALTERNATIVE.

TABLE BELOW. THE STANDARDS CONTAINED IN THE PENNDOT PUBLICATION 408 ARE AN ACCEPTABLE

THE PHYSICAL PARAMETERS OF THE COMPOST SHOULD COMPLY WITH THE STANDARDS AS SHOWN IN THE

ACCEPTABLE AS THE ORGANIC COMPONENT OF THE MIX.

AND BARK CHIPS, GROUND CONSTRUCTION DEBRIS OR REPROCESSED WOOD PRODUCTS ARE NOT

COMPOST PRODUCT SHOULD NOT RESEMBLE THE RAW MATERIAL FROM WHICH IT WAS DERIVED. WOOD

ODORS AND SHOULD BE SEASONABLY FREE (<1% BY DRY WEIGHT) OF MAN-MADE FOREIGN MATTER. THE

COMPOST SHOULD BE AEROBICALLY COMPOSTED. THE COMPOST SHOULD POSSESS NO OBJECTIONABLE

AGRICULTURE, FOOD, STUMP GRINDINGS, AND YARD OR WOOD/BARK ORGANIC MATTER SOURCES. THE

COMPOST SHOULD BE A WELL DECOMPOSED, WEED-FREE ORGANIC MATTER DERIVED FROM

COMPOST STANDARDS

SOLUBLE SALT CONCENTRATION

PARTICLE SIZE

MOISTURE CONTENT

pH

ORGANIC PORTION

ORGANIC MATTER CONTENT

5.0 DS/M (MMHOS/CM) MAXIMUM

30% - 50% PASS THROUGH 3/8" SCREEN

30% - 60%

5.5 - 8.5

FIBROUS AND ELONGATED

25% - 100% (DRY WEIGHT BASIS)

NOT TO SCALE

HEIGHT.

FILTER SOCK MAY BE STACKED ONTO DOUBLE 24" DIAMETER SOCKS IN PYRAMIDAL CONFIGURATION FOR ADDED

COMPOST SOCKS MAY BE STACKED AND STAKED SO AS TO FORM A TRIANGULAR CROSS SECTION. 18-INCH DIAMETER

PLASTIC LINERS SHOULD BE REPLACED WITH EACH CLEANING OF THE WASHOUT FACILITY.

ACCUMULATED MATERIALS SHOULD BE REMOVED WHEN THEY REACH 75% CAPACITY.

IMMEDIATELY.

INSPECT WASHOUT FACILITIES DAILY. DEACTIVATE AND REPAIR OR REPLACE DAMAGE OR LEAKING WASHOUTS

OF WHEN THEY REACH THE CLEANOUT LEVEL.

THAT THEY ARE WATERTIGHT, AND APPROPRIATELY SIZED. ACCUMULATED MATERIALS MUST BE PROPERLY DISPOSED

ENSURE THAT THE CONTAINERS ARE INTENDED BY THE MANUFACTURER FOR USE AS CONCRETE WASHOUT BMPS, PREFABRICATED WASHOUT CONTAINERS MAY BE USED AS A SUITABLE ALTERNATIVE. CARE SHOULD BE TAKEN TO

NOTES:

PLAN VIEW

SPACED 5' OC (TYP)

2" x 2" x 36" WOOD STAKES

FILTER RING

ON UPSLOPE SIDE OF

SOCK 4' MIN OVERLAP

24" COMPOST FILTER

INTO FILTER RING

WASHOUT WATER

DIRECT CONCRETE

COMPOST SOCK CONRETE WASHOUT

SUPPLEMENT.

AND VEGETATED OR REMOVED. IN THE LATTER CASE, THE MESH SHALL BE CUT OPEN AND THE MULCH SPREAD AS A SOIL

UPON STABILIZATION OF THE AREA TRIBUTARY TO THE SOCK, STAKES SHALL BE REMOVED. THE SOCK MAY BE LEFT IN PLACE 7.

POLYPROPYLENE SOCKS SHALL BE REPLACED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.

BIODEGRADABLE FILTER SOCKS SHALL BE REPLACED AFTER 6 MONTHS; PHOTODEGRADABLE SOCKS AFTER 1 YEAR. 6.

MANUFACTURER'S SPECIFICATIONS OR REPLACED WITHIN 24 HOURS OF INSPECTION.

SOCKS SHALL BE INSPECTED WEEKLY AND AFTER EACH RUNOFF EVENT. DAMAGED SOCKS SHALL BE REPAIRED ACCORDING TO 5.

DISPOSED IN THE MANNER DESCRIBED ELSEWHERE IN THE PLAN.

ACCUMULATED SEDIMENT SHALL BE REMOVED WHEN IT REACHES HALF THE ABOVEGROUND HEIGHT OF THE SOCK AND 4.

TRAFFIC SHALL NOT BE PERMITTED TO CROSS FILTER SOCKS.3.

SPECIFIED BY THE MANUFACTURER.

CONTROL PROGRAM MANUAL (363-2134-008). STAKES MAY BE INSTALLED IMMEDIATELY DOWNSLOPE OF THE SOCK IF SO

EXCEED THAT IN THE EROSION AND SEDIMENT CONTROL REPORT AND/OR THE PADEP EROSION AND SEDIMENT POLLUTION

8 FEET UP SLOPE AT 45 DEGREES TO THE MAIN SOCK ALIGNMENT. MAXIMUM SLOPE LENGTH ABOVE ANY SOCK SHALL NOT

COMPOST FILTER SOCK SHALL BE PLACED AT EXISTING LEVEL GRADE. BOTH ENDS OF THE SOCK SHALL BE EXTENDED AT LEAST 2.

TABLE BELOW.

SOCK FABRIC SHALL MEET STANDARDS AS SHOWN IN TABLE BELOW. COMPOST SHALL MEET THE STANDARDS AS SHOWN IN 1.

NOTES:

A-102

7 5

NEW

ACCESSIBLE

UNISEX TOILET

EXISTING

(UNISEX) TOILET

EXISTING

LOBBY

<E> MEETING

ROOM

EXISTING

JANITOR

1' - 4" +/- 4' - 7 3/4" +/-

E X

IS

T

IN

G

L E

N G

T H

T O

R E

M A

IN

V .I

.F

EXISTING

STORAGE

EXISTING OPEN

OFFICE M

IN

2'-0" W x 5'-6" L x 34" H

LOW ADA COUNTERTOP

(LIGHT SHADED)

1'-10" W x 4'-4" L x 34" H

LOW ADA COUNTERTOP

(LIGHT SHADED)

60" x 60" CLEAR

SPACE AT DOOR

30" x 48" FORWARD

APPROACH

30" x 48" PARALLEL

APPROACH

30" x 48" FORWARD

APPROACH

NEW STUD WALL,

DOOR / FRAME AND

HARDWARE

1'-0" W x 4'-5" L x 42" H

HIGH COUNTERTOP

(DARK SHADED)

4' - 5" 1' - 10"

V .I

.F

48" x 60" CLEAR SPACE

AT SIDE APPROACH

5'-0" DIAMETER TURNING

SPACE AT CORRIDOR

A-102

A-101 2

A-1013

INFILL OPENING w/

WOOD STUD WALL

30" x 48" PARALLEL

APPROACH

A-101

LIMIT OF NEW

FLOOR FINISHES

LIMIT OF NEW

FLOOR FINISHES

IF TOTAL

REPLACEMENT

OF EXISTING

<E> FLOOR FINISHES

TO REMAIN

EXISTING

CORRIDOR

<E> FLOOR FINISHES

TO REMAIN

<E> FLOOR FINISHES

TO REMAIN

W01B

W01B

W01B

W01B

A-101

SIGN TYPE A

SIGN

TYPE B

A-101

SIGN

TYPE A1

SLIDER

C E

IL

IN

G H

E

IG

H T

V

.I .F

V A

R

IF

Y I N

F

IE

L D

H E

IG

H

T

MIN.

1' - 6"

WINDOW WIDTH

3' - 4" 1' - 0"

C O

U N

T E

R T

O P

H

IG

H

P A

T R

O N

C O

U N

T E

R T

O P

L O

W A

D A

1'-0" W x 4'-5" L x 42" HIGH PATRON COUNTERTOP w/

4" HIGH BACKSPLASH

CONTINUOUS CLEAT

RAXX COUNTER SUPPORT

MOUNTED WITHIN WALL

2'-0" W x 5'-6" L x 34" H

LOW ADA COUNTERTOP

3'-4" W x 4'-0" L SLIDER

TRANSACTION WINDOW

NEW BASE TO

MATCH EXISTING

PAINTED NEW DRYWALL -

COLOR TO BE SELECTED

BY OWNER

A-101

SIGN TYPE B

First Floor 8' - 8"

C O

U N

T E

R T

O P

H

IG

H

P A

T R

O N

2' - 0"1' - 10"

EXISTING WINDOW

TO REMAIN

1'-10" W x 4'-4" L x 34"H

LOW ADA

COUNTERTOP

CONTINUOUS CLEAT -

BOTH SIDES

RAXX COUNTER

SUPPORT MOUNTED

WITHIN WALL

(BOTH SIDES)

NEW BASE TO MATCH

EXISTING

BRACKET SUPPORTS AT

3'-0" (MAX.)

NEW BASE TO MATCH

EXISTING

EXISTING BASE

TO REMAIN

2'-0" W x 5'-6" L x 34" H

LOW ADA

COUNTERTOP

1'-0" W x 4'-5" L x 42" H HIGH PATRON COUNTERTOP w/ 4"

HIGH BACKSPLASH

EXISTING ENTRANCE

DOORS TO REMAIN

A-101

A-101

A-101

A-101

First Floor 8' - 8"

SLIDER

W

IN

D O

W H

E

IG

H T

C O

U N

T E

R T

O P

L O

W A

D A

2'-0" W x 4'-4" L x 34" H

LOW ADA COUNTERTOP

RAXX COUNTER

SUPPORT MOUNTED

WITHIN WALL

NEW BASE TO MATCH

EXISTING

V

E R

IF

Y

I N

F

IE

L D

C E

IL

IN

G H

E

IG

H T

A-101

PHASE 3 - GENERAL NOTES

GENERAL NOTES:

1.1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES,

AND SHALL CONFORM TO ALL APPLICABLE MUNICIPAL, STATE, AND FEDERAL

REGULATIONS HAVING JURISDICTION. (INCLUDING ACCESSIBILITY STANDARDS AND ADA

REQUIREMENTS).

1.2. NOT USED.

1.3. THE CONTRACTOR SHALL VISIT THE SITE AND BE KNOWLEDGEABLE OF CONDITIONS

THEREON. THEY SHALL INVESTIGATE, VERIFY, AND BE RESPONSIBLE FOR ALL CONDITIONS

OF THE PROJECT AND SHALL NOTIFY THE OWNER OF ANY SITE CONDITIONS REQUIRING

MODIFICATION BEFORE PROCEEDING WITH THE WORK.

1.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION AND CONTINUOUS

MAINTENANCE OF ALL WORK FROM DAMAGE AND SHALL PROTECT THE OWNERS’ PROPERTY

FROM DAMAGE OR LOSS BY DUST, DIRT, WATER, THEFT, FIRE OR ANY OTHER PHYSICAL

DAMAGE IN CONNECTION WITH THE CONTRACT.

1.5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL KNOWN UTILITIES AND

TO COORDINATE CONSTRUCTION AROUND KNOWN OR UNKNOWN UTILITIES.

1.6. THE ARCHITECT SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE,

HANDLING, REMOVAL, DISPOSAL, OR EXPOSURE OF PEOPLE TO HAZARDOUS MATERIALS IN

ANY FORM, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED

BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES.

1.7. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE OF ANY CHANGES THAT INVOLVE

ADDITIONAL MONEY AND/OR TIME TO THE ARCHITECT AND OWNER WITHIN FIVE DAYS OF ITS

DISCOVERY AND BEFORE PROCEEDING WITH THE WORK. THIS SHALL BE SUBMITTED IN THE

FORM OF A UNIT COST, AND DETAILED LUMP SUM BREAKDOWN. COST EVENTS WITHOUT AN

ACCOMPANYING BREAKDOWN WILL NOT BE CONSIDERED FOR REVIEW AND APPROVAL.

PROCEED WITH WORK ONLY AFTER OWNER HAS APPROVED LUMP SUM.

1.8. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY BUILDING PERMITS

AND MUST BE LICENSED TO WORK WITHIN THE TOWNSHIP OR MUNICIPALITY WHERE THE

PROJECT IS LOCATED.

1.9. THE CONTRACT DOCUMENTS ARE A COMPLETE SET. GENERAL CONTRACTOR IS

RESPONSIBLE FOR ALL WORK REGARDLESS OF WHICH SHEET THE WORK IS SHOWN ON.

THE ARCHITECT RESERVES THE RIGHT TO SELECT WHICH WORK APPLIES WHEN

DISCREPANCIES OCCUR BETWEEN SHEETS EVEN IF THE SELECTION IS MORE STRINGENT.

1.10. ALL COLORS TO BE SELECTED BY OWNER FROM MANUFACTURERS FULL RANGE OF

COLORS INCLUDING NON-STANDARD COLORS.

1.11. INSTALL ALL MATERIALS IN ACCORDANCE WITH MANUFACTURERS INSTALLATION

REQUIREMENTS AND DETAILS INCLUDING ALL PREPARATION REQUIREMENTS AND PROVIDE

MANUFACTURERS FULL WARRANTIES.

1.12. ARCHITECT RESERVES THE RIGHT TO REQUIRE REPLACEMENT OF ANY MATERIAL NOT

PROPERLY INSTALLED OR DAMAGED DURING INSTALLATION.

1.13. FIELD PAINTING OR TOUCH-UP PAINTING OF PRE-FINISHED MATERIALS IS NOT

ACCEPTABLE WITHOUT PRIOR APPROVAL OF THE ARCHITECT.

1.14. PROVIDE JOINT SEALANT ADHESION TESTING FOR ALL JOINT SEALANT APPLICATIONS.

1.15. THE CONTRACTOR MUST NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES

AND ERRORS WITH ANY AND ALL OF THE CONSTRUCTION DOCUMENTS PRIOR TO BEGINNING

THE WORK.

1.16. THE CONTRACTOR SHALL COMPLY WITH, AND PERFORM ITS WORK IN ACCORDANCE

WITH ALL APPLICABLE LAWS, STATUTES, ORDINANCES,LAWFUL ORDERS OF

GOVERNMENTAL AUTHORITIES, BUILDING CODES, RULES AND REGULATIONS, UNLESS THE

CONTRACT DOCUMENTS REQUIRE A HIGHER OR GREATER STANDARD, IN WHICH CASE THE

CONTRACTOR SHALL CONFORM TO SUCH HIGHER OR GREATER STANDARD. IF THE

CONTRACTOR RECOGNIZES THAT PORTIONS OF THE CONTRACT DOCUMENTS DO NOT MEET

THE STANDARDS ESTABLISHED THEREBY, THE CONTRACTOR SHALL PROMPTLY NOTIFY THE

ARCHITECT, THE CONSTRUCTION MANAGER (IF APPLICABLE) AND THE OWNER IN WRITING

BEFORE PROCEEDING WITH THE WORK.

1.17. EACH CONTRACTOR SHALL ACQUAINT HIMSELF WITH THE WORK TO BE DONE AND

MATERIALS AND EQUIPMENT TO BE INSTALLED BY HIMSELF AND OTHERS, AND COORDINATE

IN ADVANCE, PRIOR TO INSTALLING ANY SYSTEM OR PORTION THEREOF.

1.18. EACH CONTRACTOR WHO FAILS TO COORDINATE THE INSTALLATION OF HIS WORK

WITH THE OTHER TRADES SHALL BEAR ALL COSTS OF EACH TRADE FOR DISCONNECTING,

REMOVAL AND RE-INSTALLATION OF AFFECTED SYSTEMS, EQUIPMENT OR PORTION

THEREOF.

1.19. CONTRACTOR TO COORDINATE ALL WORK WITH OWNER SUPPLIED ITEMS.

1.20. CLOSE OPENINGS AT DOORS AND FRAMES.

1.21. NOT USED.

1.22. GENERAL CONTRACTOR SHALL PROVIDE WOOD BLOCKING AS REQUIRED IN WALLS TO

SUPPORT WALL-MOUNTED ITEMS, AND ACCESSORIES. COORDINATE REQUIREMENTS WITH

OWNER.

1.23. GENERAL CONTRACTOR TO REPLACE ANY DEFECTIVE MATERIALS AT THE DISCRETION

OF THE ARCHITECT.

1.24. ALL INTERIOR FINISH MATERIALS AND COLOR SELECTIONS ARE BY OWNER.

1.25. GENERAL CONTRACTOR IS RESPONSIBLE FOR OVERALL PROJECT SCHEDULE AND

COORDINATING WORK WITH ALL SUB-CONTRACTORS.

1.26. PROVIDE SEALANT AS DIRECTED BY ARCHITECT FOR ALL BUILDING JOINTS. SEALANT

COLOR TO MATCH ADJACENT MATERIAL COLOR AND APPROVED BY ARCHITECT FROM FIELD

SAMPLE AND MAY REQUIRE CUSTOM COLOR.

1.27. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN

OVER ALL SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE PROFESSIONAL IN

WRITING OF ANY DISCREPANCIES, OMISSIONS AND / OR CONFLICTS BEFORE

COMMENCEMENT OF THE WORK.

1.28. THE CONTRACTOR SHALL PROTECT EXISTING WORK AND OTHER NEW WORK BY

OTHER CONTRACTORS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO

EXISTING WORK OR WORK BY OTHERS INCURRED WHILE FULFILLING THE OBLIGATION OF

THE CONTRACT.

1.29. THE CONTRACTOR SHALL PERFORM ALL NEW WORK IN ACCORDANCE WITH ALL

APPLICABLE CURRENT BUILDING CODES, ORDINANCES, REGULATIONS, AND ALL

ACCESSIBILITY AGENCIES, AND REQUIREMENTS BY AHJ.

1.30. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL INSPECTIONS AND

CERTIFICATES AND SHALL GIVE ALL LEGAL NOTICES.

1.31. ALL WORK SHALL CONFORM WITH APPLICABLE INDUSTRY AND MANUFACTURERS

PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS ALL

REQUIREMENTS IN THE DRAWINGS AND SPECIFICATIONS, ANY CONFLICTING REQUIREMENTS

OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE PROFESSIONAL'S ATTENTION

PRIOR TO PROCEEDING WITH THE WORK.

1.32. NO SUBSTITUTIONS FOR ITEMS SPECIFIED WILL BE ACCEPTED WITHOUT PRIOR

WRITTEN ACCEPTANCE FROM THE DESIGN PROFESSIONAL. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR SUPPLYING THE DESIGN PROFESSIONAL WITH ALL SAMPLES AND

COMPARATIVE PRODUCT DATA REQUIRED TO EVALUATE PROPOSED SUBSTITUTIONS IN A

TIMELY MANNER SO AS NOT TO PRECLUDE PROCUREMENT OF THE PRODUCT ORIGINALLY

SPECIFIED OR ANY PROPOSED SUBSTITUTE.

1.33. WHERE REFERENCE IS MADE IN THESE DOCUMENTS TO BUILDING / SUB-CONTRACTOR,

IT SHALL REFER TO BUILDER, GENERAL CONTRACTOR, AND ALL SUB-CONTRACTORS AND

THEIR EMPLOYEES.

1.34. SUB-CONTRACTOR OR BUILDER UNDERSTANDS THAT DRAWINGS GRAPHICALLY

DEPICT DESIGN INTENT OF THE PROJECT. LOCATIONS AND DIMENSIONS SHOWN ON

DRAWING ARE DIAGRAMMATIC. BUILDER/CONTRACTOR UNDERSTAND THAT DRAWINGS

SHOWN THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF WORK AND ARE NOT

INTENDED TO BE SCALED FOR MEASUREMENT OR SERVE AS SHOP DRAWINGS.

1.35. SUB-CONTRACTOR/BUILDER SHALL PROPERLY FABRICATE, TRANSPORT, INSTALL

ERECT, CONSTRUCT AND TEST, FURNISH AND SUPPLY ALL LABOR MATERIALS, EQUIPMENT,

APPARATUS, APPLIANCES, AND ALL OTHER ITEMS AND EXPENSES NECESSARY TO

PROPERLY COMPLETE THE WORK IN PLACE AND READY FOR OPERATION OR USE AS

INTENDED FOR BY THE ARCHITECT.

1.36. SUB-CONTRACTOR/BUILDER SHALL BE FAMILIAR WITH PROVISION OF ALL APPLICABLE

CODES, SHALL ENSURE COMPLIANCE WITH SAME AND SHALL BE RESPONSIBLE FOR AND BE

REQUIRED TO DISCOVER, THROUGH EXERCISING CARE, SKILL AND DILIGENCE IN REVIEWING

THE CONSTRUCTION DRAWINGS, ANY OMISSION, AND DISCREPANCIES AND SHALL BRING

SAME TO THE ATTENTION OF THE ARCHITECT PRIOR TO CONSTRUCTION.

1.37. BY EXECUTING THE CONTRACT, THE SUB-CONTRACTOR/BUILDER WARRANTS THAT HE

SHALL CLOSELY INSPECTED BUILDING, AND HAS DETERMINED TO HIS SATISFACTION THE

PHYSICAL CONDITION OF SUCH, FAMILIARIZED HIMSELF WITH THE LOCAL CONDITIONS

UNDER WHICH THE WORK IS TO BE PERFORMED, CORRELATED HIS OBSERVATIONS WITH

THE REQUIREMENTS OF THE CONSTRUCTION DRAWINGS, AND KNOWS OF NO OTHER

INFORMATION REQUIRED TO COMPLETE THE WORK AS INTENDED FOR BY THE ARCHITECT,

AND AS PER LOCAL JURISDICTION REQUIREMENTS.

1.38. IF ANY ITEM OR MATERIALS IS NOT KNOWN OR OMITTED ON THE DRAWINGS, BUT IS

OTHERWISE REASONABLY INFERABLE THEREFROM, THE SUB-CONTRACTOR/ BUILDER SHALL

INFORM ARCHITECT, AND BE REQUIRED TO FURNISH AND INSTALL SUCH ITEM OR MATERIAL

WHICH CONFORM TO THE TYPE AND QUALITY OF SIMILAR ITEMS OTHERWISE ESTABLISHED

IN THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS.

1.39. WHERE A TYPICAL DETAIL IS SHOWN OR INDICATED ON THE DRAWINGS, THAT

CONDITION SHALL BE REPRESENTATIVE OF AND SHALL CONSTITUTE THE STANDARD FOR

WORKMANSHIP, MATERIALS, AND PERFORMANCE FOR CONDITIONS AND MATERIALS AND

WORKMANSHIP THROUGHOUT CORRESPONDING CONDITION THROUGHOUT THE WORK.

1.40. THE SUB-CONTRACTOR/BUILDER ARE RESPONSIBLE FOR THOROUGHLY EXAMINING

ALL DRAWINGS, SPECIFICATIONS AND APPLICABLE CODES, AS WELL AS MAKING ALL ACTUAL

MEASUREMENTS AND ESTABLISHING ALL ACTUAL DIMENSIONS FOR EACH PARTICULAR TYPE

OF WORK, AND FOR CO-COORDINATING THE WORK DESCRIBED, AND ALSO RESPONSIBLE

FOR DETERMINING THE EXACT SCOPE OF WORK FOR EACH SECTION, AS WELL AS

CHECKING CROSS REFERENCES OF WORK, AND ANY WORK EXCLUDED FROM ANY SECTION.

ELECTRONIC DOCUMENTS:

1.1. GREENFIELD ARCHITECTS LTD. IS PROVIDING BY AGREEMENT, MATERIALS STORED

ELECTRONICALLY. THE PARTIES RECOGNIZE THAT DATA, PLANS, SPECIFICATIONS, REPORTS,

DOCUMENTS, OR OTHER INFORMATION RECORDED ON OR TRANSMITTED AS ELECTRONIC

MEDIA ARE SUBJECT TO UNDETECTABLE ALTERATION, EITHER INTENTIONAL OR

UNINTENTIONAL, DUE TO, AMONG OTHER CAUSES, TRANSMISSION, CONVERSION, MEDIA

DEGRADATION, SOFTWARE ERROR, OR HUMAN ALTERATION, ACCORDINGLY, ALL SUCH

DOCUMENTS ARE PROVIDED TO THE PARTIES FOR INFORMATIONAL PURPOSES ONLY AND NOT

AS AN END PRODUCT NOR AS A RECORD DOCUMENT. ANY RELIANCE THEREON IS DEEMED

TO BE UNREASONABLE AND UNENFORCEABLE. THE SIGNED AND/OR SEALED HARD COPIES OF

THE ARCHITECT'S INSTRUMENTS OF SERVICE ARE THE ONLY TRUE CONTRACT DOCUMENTS OF

RECORD.

DOCUMENTS, GENERAL:

1.1. PRIME CONTRACTORS FOR EACH TRADE ARE ADVISED THAT INFORMATION PERTINENT TO

THEIR WORK MAY OCCUR IN OTHER PORTIONS OF THE CONTRACT DOCUMENTS.

1.2. SHOULD THERE BE ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS THAT

WOULD CAUSE AN AWKWARD OR IMPROPER OR EXPOSED INSTALLATION, IT SHALL BE

BROUGHT TO THE ARCHITECT’S ATTENTION FOR CLARIFICATION PRIOR TO INSTALLATION OF

SAID WORK.

1.3. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DOCUMENTS SHALL BE

CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR’S EXPENSE, AND AT NO ADDITIONAL

COST TO THE OWNER OR ARCHITECT.

1.4. ALL NOTES ARE TO BE REVIEWED AND APPLIED TO RELATED BUILDING COMPONENTS.

NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. NOTES ON

ANY ONE SHEET ARE TO BE APPLIED TO RELATED DRAWING SHEETS AND DETAILS.

1.5. ANY DETAILS, SYSTEMS, OR MATERIALS WHICH ARE PROPOSED TO BE CHANGED MUST

FIRST BE REVIEWED BY THE OWNER, ARCHITECT, AND GENERAL CONTRACTOR PRIOR TO THE

PREPARATION OF SHOP DRAWINGS.

1.6. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AND COORDINATE

ALL TRADES AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES

ARE FOUND, THEY SHALL BE BROUGHT TO THE ARCHITECT’S ATTENTION FOR CLARIFICATION

BEFORE COMMENCING WITH THE WORK.

1.7. DIMENSIONS SHALL NOT BE SCALED FROM DRAWINGS.

1.8. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE SPECIFIC

DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE ARCHITECT

BEFORE PROCEEDING WITH THE WORK.

1.9. PROVIDE ENTIRE SETS OF DRAWINGS TO SUB-CONTRACTORS FOR COORDINATION.

1.10. THESE DRAWINGS DO NOT CONTAIN INFORMATION WITH REGARD TO CONSTRUCTION

SAFETY PROCEDURES. THE CONTRACTOR IS RESPONSIBLE FOR ALL CONSTRUCTION SAFETY

AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH STATE AND FEDERAL SAFETY GUIDE

LINES.

1.11. THE GENERAL CONTRACTOR SHALL INCLUDE IN THEIR BID THE HIGHEST QUALITY AND

GREATEST QUANTITY FOR RESOLVING ALL CONFLICTS IN THE CONSTRUCTION

DOCUMENTATION WHICH IS IMPLIED OR DEFINED.

1.12. NO CHANGES SHALL BE MADE TO THESE DOCUMENTS EITHER IN WHOLE OR IN PART

WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT.

MISCELLANEOUS NOTES:

1.1. ALL DISSIMILAR…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .