2-Mont Harmon MS Slab Replacement - Bid Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- RA26-91
- Issued by
- Cache County, Utah
About this file
This is a set of bid drawings for the Mont Harmon Middle School Gymnasium Floor Replacement project issued by Carbon School District, located in Price, Utah. The project involves the demolition of an existing 5-inch wood floor system and the replacement with a 5-inch reinforced concrete slab-on-grade. The scope of work includes removal of the existing wood floor and associated blocking, disposal of materials, protection of adjacent structural elements including bleachers and basketball standards, installation of new concrete flooring with specified reinforcement (#4 rebar at 18 inches on center each way), installation of proper vapor barriers and gravel base, and restoration of thresholds and finishes. A non-mandatory pre-bid project walk is scheduled for Wednesday, February 11, 2026, at 12:30 PM on site (60 West 400 North, Price, Utah). Questions must be submitted through Bonfire no later than February 12, 2026, at 12:00 PM. Sealed physical bids or electronic submissions via Bonfire are due Friday, February 13, 2026, at 2:00 PM sharp to Carbon School District's offices (251 West 400 North, Price, Utah).
The bid documents specify detailed structural and construction requirements including concrete mix design with 4,000 PSI minimum compressive strength, structural steel connections and bolting specifications, earthwork and fill requirements, control joint spacing, and quality assurance inspections in accordance with ACI 318, AISC standards, and applicable building codes. The architect is Naylor Wentworth Lund Architects, and the civil engineer is Jones & DeMille Engineering, Inc. The drawings include demolition plans, finish floor plans, structural details, and elevations showing door openings, wall sections, and joint details. No specific pricing information, contract term, or award date is provided in the bid drawings themselves; these details would be contained in the separate bidding documents accessible through the Bonfire platform.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A naylor wentworth lund a r c h i t e c t s
NW
L
PR
OJ
EC
T
IS
SU
E
DA
TE
DR
AW
IN
G
IS
SU
E
2 3 4 5 6
B
C
D
E
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
COVER SHEET
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce, Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
PL
AC
EM
EN
T
FOR
C I T Y
M A P
V I C I N I T Y
M A P
CONSULTANTS
723 WEST PACIFIC AVENUE, SUITE 101 | SALT LAKE CITY, UT 84104
MONT HARMON SLAB REPLACEMENT
CARBON SCHOOL DISTRICT
BID SET | 27 January 2026
ARCHITECT
NAYLOR WENTWORTH LUND
ARCHITECTS
723 Pacific Avenue Suite 101 Salt Lake City, UT 84104
801.355.5959 | nwlarchitects.com
Principal | Philip Wentworth PM | Erin Youngberg
OWNER
CARBON SCHOOL DISTRICT
251 W 400 N
PRICE, UT 84501
435.637.1732
Business Admin | Darin Lancaster Facilities Manager | Jared Hansen
CIVIL
JONES & DEMILLE
ENGINEERING, INC.
1675 South Highway 10 Price, UT 84501
435.637.8266 | jonesanddemille.com
Principal | Daniel Hawley PM | Cody Peck
DATE REVISION
WALL TAG
DOOR TAG
WINDOW TAG
KEYNOTE TAG
VIEW TITLE
View Scale
A400A
##xxxsd
SIM
A101
Name Elevation
A101
SIM
A101
SIM
BUILDING SECTION
WALL SECTION
DETAIL SECTION
DETAIL CALLOUT
ELEVATION HEAD
A101A
W1
INTERIOR ELEVATION
SIM
A101
A101
A101
A101
A101
A101
A101
ALTERNATE INTERIOR
ELEVATION
EXTERIOR ELEVATION
A101
1 A101
ENLARGED EXTERIOR
ELEVATION
A101 F1 W1 C1
B1
ROOM TAG
ROOM FINISHES TAG
? MATERIAL TAG
XXXXX LIGHTING TAG
1t W
H D
Comments
CASEWORK TAG
CL0015' -10" CEILING TAG
00.00.XX
XXX
W1 GLAZING TAG
Sheet Index
Number Sheet Name
G001 COVER SHEET
A100 OVERALL FLOOR PLAN
D101 GYM DEMO PLAN
A201 DETAILS
SYMBOLS LEGEND
A101 FINISH FLOOR PLAN
G101
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
PIRATES
MONT HARMON
A naylor wentworth lund a r c h i t e c t s
NW
L P
RO
JE
CT
ISS
UE
DA
TE
DR
AW
ING
IS
SU
E
2 3 4 5 6
B
C
D
E
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce.
Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
ME
DIA
TIO
N
DATE REVISION
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
N
OVERALL FLOOR
PLAN
NTS
OVERALL FLOOR PLAN1 A100
N O
T
FO
R C
O N
ST
R
U C
TI
1. FABRICATION, ERECTION, AND MATERIALS SHALL CONFORM WITH THE AISC
SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL
STEEL FOR BUILDINGS AND THE CURRENT EDITION OF THE IBC.
2. STRUCTURAL STEEL SHAPES SHALL CONFORM TO THE FOLLOWING;
A. PLATES & BARS & MISCELLANEOUS SHAPES: ASTM A36
4. WELDING DONE BY THE ELECTRIC ARC PROCESS IN ACCORDANCE WITH "AWS"
STANDARDS: USE ONLY CERTIFIED WELDERS.
5. BUTT WELDS: COMPLETE PENETRATION, GRIND SMOOTH.
6. ERECT ALL STRUCTURAL STEEL PLUMB AND TRUE TO LINE.
7. INSTALL TEMPORARY BRACING AND LEAVE IN PLACE UNTIL OTHER MEANS ARE
PROVIDED TO ADEQUATELY BRACE STRUCTURE.
8. HOLES FOR UNFINISHED BOLTS OR RIVETS: SAME NOMINAL DIAMETER AS BOLT OR
RIVET PLUS 1/16".
9. BOLT LOCATIONS: STANDARD AISC GAUGE AND PITCH FOR UNO.
10. HIGH STRENGTH BOLTS: 3/4" DIAMETER A325-N TYP. UNO. SEE AISC SPECIFICATION
FOR STRUCTURAL JOINT USING ASTM A325 OR A490 BOLTS.
11. BOLTED CONNECTIONS: SNUG-TIGHTENED UNO.
12. SHORING IS NOT REQUIRED FOR COMPOSITE METAL DECKING, BEAMS, OR
GIRDERS UNO.
13. DO NOT PAINT TOPS OF BEAMS & GIRDERS.
STRUCTURAL STEEL
1. ENGINEER SHALL VERIFY CONDITION AND/OR ADEQUACY OF ALL
SUBGRADES, FILLS, AND BACK FILLS, ETC.
2. SHORE AND BRACE AS REQUIRED.
3. DE-WATER AS REQUIRED TO REMOVE STANDING WATER FROM
EXCAVATIONS.
4. CLEAN ALL DEBRIS FROM EXCAVATIONS.
5. NOTIFY ENGINEER 48 HOURS IN ADVANCE OF PLACING CONCRETE.
6. SCARIFY SOILS IN BOTTOM OF EXCAVATIONS 6", MOISTURE CONDITION
TO WITHIN 2% OF OPTIMUM MOISTURE, AND COMPACT TO 95% OF
MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557 PRIOR TO
PLACEMENT OF STRUCTURAL FILL.
7. EXTEND STRUCTURAL FILL LATERALLY A DISTANCE EQUAL TO 1/2 THE
STRUCTURAL FILL DEPTH BEYOND EDGE OF FOOTING ON EACH SIDE.
8. IMPORTED STRUCTURAL FILL USED FOR SUPPORT OF FOUNDATIONS AND
FLOOR SLABS:
A. WELL-GRADED
B. NON-EXPANSIVE
C. FREE OF ORGANICS AND ALL DELETERIOUS MATERIALS
D. PERCENT PASSING NO. 200 SIEVE: 30% MAX
E. LIQUID LIMIT: 30 OR LESS
F. PLASTICITY INDEX: 10 OR LESS
9. COMPACT STRUCTURAL FILL BENEATH FOOTINGS TO 95% OF MAXIMUM
DRY DENSITY DETERMINED BY ASTM D1557.
10. PLACE STRUCTURAL FILL IN MAXIMUM EIGHT-INCH THICK LOOSE LIFTS
TO ACHIEVE ADEQUATE COMPACTION.
EARTHWORK
1. NOTES AND TYPICAL DETAILS SHALL APPLY UNLESS OTHERWISE SHOWN OR NOTED
ON PLANS.
2. DETAILS OF CONSTRUCTION NOT FULLY SHOWN SHALL BE OF THE SAME NATURE
AS SHOWN FOR SIMILAR CONDITION.
3. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, PROPERTY LINES ETC.
ON THE JOB.
5. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER WHERE CONFLICT
OCCURS ON ANY OF THE CONTRACT DRAWINGS OR DOCUMENTS. CONTRACTOR IS
NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF THE STRUCTURE THAT
IS IN CONFLICT UNTIL CONFLICT IS RESOLVED WITH AFFECTED PARTIES.
6. IF CONTRACTOR'S WORK IS NOT CONSTRUCTED ACCORDING TO APPROVED
CONSTRUCTION DOCUMENTS (INCLUDING STAMPED WRITTEN COMMUNICATIONS),
CONTRACTOR SHALL EITHER:
A. REMOVE THE NON-CONFORMING WORK AND RECONSTRUCT THE WORK
ACCORDING TO DRAWINGS, AT CONTRACTOR'S OWN EXPENSE.
B. PAY FOR AND PROVIDE AN EVALUATION AND LETTER FROM THE ENGINEER
STATING THAT THE NON-CONFORMING WORK MEETS APPLICABLE BUILDING
CODES.
C. PAY FOR AND PROVIDE AN EVALUATION AND LETTER FROM THE ENGINEER
STATING THAT THE NON-CONFORMING WORK DOES NOT MEET APPLICABLE
BUILDING CODES AND DETAILING THE UPGRADES THAT ARE REQUIRED TO BRING
THE NON-COMPLIANT WORK INTO COMPLIANCE.
7. VERBAL COMMUNICATIONS SHALL NOT BE CONSIDERED PART OF THE APPROVED
CONSTRUCTION DOCUMENTS.
GENERAL NOTES
CONCRETE SLAB-ON-GRADE
JOINTS
MAXIMUM CONTROL JOINT SPACING
SLAB THICKNESS, IN.
MAXIMUM JOINT SPACING, FT.
UNREINFORCED REINFORCED
4 8 10
5 10 12
6 12 15
8 16 20
1. PROVIDE CONTROL JOINTS IN ALL REINFORCED AND UNREINFORCED
SLABS-ON-GRADE ACCORDING TO TYPICAL CONCRETE JOINTS DETAIL.
2. WHERE TWO REINFORCED SLABS ABUT, OR WHERE ONE REINFORCED SLAB IS
DIVIDED INTO MULTIPLE PLACEMENTS, PROVIDE PLATE DOWELS AT COLD JOINT
PER TYPICAL CONCRETE JOINTS DETAIL.
3. PROVIDE EXPANSION JOINTS AT BUILDING CORNERS IN BOTH DIRECTIONS IN
SLABS TOUCHING BUILDING.
4. TOOL CONTROL JOINTS INTO FRESH CONCRETE OR SAW CUT CONTROL JOINTS
INTO HARDENED CONCRETE.
5. SAW-CUT JOINTS AS SOON AS POSSIBLE AFTER PLACEMENT, BEFORE
SHRINKAGE CRACKS CAN DEVELOP.
6. CONTROL JOINT MINIMUM DEPTH: ¼ OF SLAB THICKNESS.
7. CONTROL JOINT LAYOUT:
A. PLACE CONTROL JOINTS TO PRODUCE PANELS THAT ARE AS SQUARE AS
POSSIBLE AND NOT EXCEEDING A LENGTH-TO-WIDTH RATIO OF 1.5 TO 1.
B. PLACE CONTROL JOINTS AT ALL ABRUPT CHANGES IN GEOMETRY.
C. AVOID WEDGE-SHAPED PANELS WITH INTERIOR ANGLES LESS THAN 45 DEGREES.
D. AVOID "T" SHAPED JOINTS.
E. AVOID "L" SHAPED PANELS.
F. IF CONTROL JOINT LAYOUT VIOLATES THESE REQUIREMENTS, EVEN IF NO
CRACKING IS VISIBLE, OWNER MAY REJECT WORK.
SPLICE LENGTH (IN.) f'c = 4,000 PSI
LOCATION
REINFORCEMENT SIZE
#11
TOP
OTHER
#10
#9
#8
#7
#6
#5
#4
#3
CONCRETE REINFORCEMENT
LAP SPLICES
1. TENSION DEVELOPMENT LENGTHS AND TENSION LAP SPLICE LENGTHS ARE BASED
ON ACI 318-19, SECTIONS 25.4.2 AND 25.5.2 RESPECTIVELY. TABULATED VALUES
FOR BEAMS OR COLUMNS ARE BASED ON TRANSVERSE REINFORCEMENT AND
CONCRETE COVER MEETING MINIMUM CODE REQUIREMENTS.
2. LAP SPLICE LENGTHS SHOWN ARE FOR CLASS B AND CASE 1.
3. TOP REINFORCEMENT IS HORIZONTAL REINFORCEMENT THAT HAS MORE THAN
TWELVE INCHES OF FRESH CONCRETE CAST BELOW IT. THIS INCLUDES
HORIZONTAL REINFORCEMENT IN WALLS. ALL VERTICAL BARS ARE CONSIDERED AS
"OTHER".
4. FOR LIGHTWEIGHT CONCRETE AGGREGATE CONCRETE, MULTIPLY TABULATED
VALUES BY 1.3.
5. REINFORCEMENT IS ASSUMED TO BE UNCOATED OR GALVANIZED.
6. FOR BARS WITH COVER OF LESS THAN 1 BAR DIAMETER OR WITH CLEAR SPACING
OF LESS THAN 2 BAR DIAMETERS, MULTIPLY TABULATED VALUES BY 2.0.
1. CONSTRUCT CONCRETE ACCORDING TO ACI 318 (LATEST VERSION).
2. DETAIL, FABRICATE, AND INSTALL REINFORCING STEEL ACCORDING TO
"MANUAL OF STANDARD PRACTICE OF REINFORCED CONCRETE
CONSTRUCTION" BY CONCRETE REINFORCING STEEL INSTITUTE
(CRSI).
3. GENERAL
A. DO NOT PLACE PIPES OR DUCTS IN CONCRETE SLABS OR WALLS
UNLESS SPECIFICALLY DETAILED.
B. REFER TO ARCHITECTURAL, STRUCTURAL, CIVIL, ELECTRICAL AND
MECHANICAL DRAWINGS FOR ALL MOLDS, GROOVES, ORNAMENTS,
CLIPS AND GROUNDS TO BE CAST IN CONCRETE.
C. DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO FACE
OF MAIN BARS AND DENOTE CLEAR COVERAGE.
4. SUBMIT CONCRETE PLACEMENT PLAN TO ENGINEER 48 HOURS PRIOR
TO EACH CONCRETE PLACEMENT.
5. CONCRETE MIX DESIGN: PREPARED BY INDEPENDENT LABORATORY
AND APPROVED BY ENGINEER OF RECORD.
6. CONCRETE
A. STRUCTURAL CONCRETE
a. MINIMUM COMPRESSIVE STRENGTH: 4,000 PSI.
b. CEMENT: ASTM C-150, TYPE II.
c. MAXIMUM WATER-CEMENT RATIO: 0.45.
7. CONCRETE EXPOSED TO EXTERIOR CONDITIONS: AIR ENTRAINED TO
5%-7% AIR CONTENT.
8. CONCRETE AGGREGATES: NATURAL SAND AND ROCK AGGREGATES
CONFORMING TO ASTM C-33 (3/4" MAX).
9. REINFORCING FIBERS:
A.NOT REQUIRED UNLESS INDICATED ON DRAWINGS.
C. MACRO-SYNTHETIC FIBERS CONFORMING TO ASTM C1116.
D. DOSAGE RATE: 4 POUNDS PER CUBIC YARD.
10. REINFORCING STEEL: ASTM A615 GRADE 60 UNO.
11. WIRE FABRIC: ASTM A-185.
12. WELDING OF REINFORCING STEEL: CONFORM TO AWS D1.4 USING
PROPER LOW HYDROGEN ELECTRODES. DO NOT TACK WELD TO
REBAR. SEE REBAR WELDING NOTE.
13. CONCRETE CLEAR COVERAGE, UNO:
A. CONCRETE PLACED AGAINST FORMS (INCLUDING CONCRETE TO BE
BACKFILLED): 2"
B. CONCRETE PLACED AGAINST GROUND: 3"
C. SLABS (ON GROUND): CENTER BAR IN SLAB.
14. PROVIDE CLASS B LAP SPLICE UNO. SEE TABLE "ACI TENSION LAP
SPLICE LENGTHS".
15. LAP SPLICE WELDED WIRE FABRIC TWO SQUARES MIN. EACH
DIRECTION.
16. CONSTRUCT CONSTRUCTION JOINTS ROUGH, OR ROUGHEN
JOINTS BY CHIPPING ENTIRE SURFACE, SANDBLASTING, OR HOSING
SURFACE 4 TO 6 HOURS AFTER PLACEMENT WITH FINE SPRAY.
REMOVE ALL LAITANCE FROM SURFACE.
17. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING ANY
CONCRETE.
18. SECURELY POSITION REINFORCING DOWELS, BOLTS, ANCHORS,
SLEEVES, ETC. TO BE EMBEDDED IN CONCRETE BEFORE PLACING
CONCRETE (WET SETTING IS PROHIBITED).
19. OBTAIN APPROVAL OF ALL AFFECTED TRADES PRIOR TO PLACING
CONCRETE.
20. MAXIMUM FREE FALL OF CONCRETE: 5'-0".
21. DO NOT USE WOOD SPREADERS. DO NOT USE WOOD STAKES IN
AREAS TO BE CONCRETED.
22. DRILL THROUGH STEEL COLUMNS AND BEAMS TO PASS
CONTINUOUS REINFORCING (1" DIA. MAX).
23. FOLLOW ACI HOT OR COLD WEATHER PLACEMENT
RECOMMENDATIONS FOR CONCRETE PLACEMENT AND CURING.
24. EXERCISE SPECIFIC CARE DURING PLACEMENT AND CURING OF
CONCRETE SLABS AND EXPOSED CONCRETE FINISHES.
CONCRETE
1. ___ STRUCTURAL STEEL (1705.2.1, AISC 360)
2. ___ COLD-FORMED STEEL DECK (1705.2.2, SDI QA/QC)
3. ___ OPEN-WEB STEEL JOISTS AND JOIST GIRDERS (TABLE 1705.2.3)
4. ___ COLD-FORMED STEEL TRUSSES SPANNING 60 FEET OR GREATER
(1705.2.4)
5. ___ CONCRETE CONSTRUCTION (TABLE 1705.3)
6. ___ WELDING OF REINFORCING BARS (AWS D1.4)
7. ___ MASONRY CONSTRUCTION (TMS 402/ACI 530/ASCE 5 AND TMS 602/ACI
530.1/ASCE 6) PROVIDE LEVEL ___ QUALITY ASSURANCE
8. ___ EMPIRICALLY DESIGNED MASONRY, GLASS UNIT MASONRY AND
MASONRY VENEER IN RISK CATEGORY IV (TMS 401/ACI 530/ASCE 5, LEVEL
B QUALITY ASSURANCE)
9. ___ VERTICAL MASONRY FOUNDATION ELEMENTS (TMS401/ACI 530/ASCE
5 AND TMS 602/ACI 530/ASCE 6)
10. ___ HIGH-LOAD DIAPHRAGMS (1705.5.1)
11. ___ METAL-PLATE-CONNECTED WOOD TRUSSES (1705.5.2)
12. ___ SOILS (TABLE 1705.6)
13. ___ DRIVEN DEEP FOUNDATIONS (TABLE 1705.7)
14. ___ CAST-IN-PLACE DEEP FOUNDATIONS (TABLE 1705.8)
15. ___ HELICAL PILE FOUNDATIONS (1705.9)
16. ___ STRUCTURAL INTEGRITY OF DEEP FOUNDATION ELEMENTS
(1705.10)
17. ___ FABRICATED ITEMS (1705.11)
18. ___ SPECIAL INSPECTIONS FOR WIND RESISTANCE (1705.12)
A. ___ STRUCTURAL WOOD (1705.12.1)
B. ___ COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION (1705.12.2)
C. ___ WIND-RESISTING COMPONENTS (1705.12.3)
19. ___ SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE (1705.13)
A. ___ STRUCTURAL STEEL (1705.13.1)
B. ___ SEISMIC FORCE-RESISTING SYSTEMS (1705.13.1.1)
C. ___ STRUCTURAL STEEL ELEMENTS (1705.13.1.2)
D. ___ STRUCTURAL WOOD (1705.13.2)
E. ___ COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION (1705.13.3)
F. ___ DESIGNATED SEISMIC SYSTEMS (1705.13.4)
G.___ ARCHITECTURAL COMPONENTS (1705.13.5)
H. ___ PLUMBING, MECHANICAL AND ELECTRICAL COMPONENTS
(1705.13.6)
I. ___ STORAGE RACKS (1705.13.7)
J. ___ SEISMIC ISOLATION SYSTEMS (1705.13.8)
K. ___ COLD-FORMED STEEL SPECIAL BOLTED MOMENT FRAMES
(1705.13.9)
20. ___ TESTING FOR SEISMIC RESISTANCE (1705.14)
21. ___ SPRAYED FIRE-RESISTANT MATERIALS (1705.15)
22. ___ MASTIC AND INTUMESCENT FIRE-RESISTANT COATINGS (1705.16)
23. ___ EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS 1705.17)
24. ___ FIRE-RESISTANT PENETRATIONS AND JOINTS (1705.18)
25. ___ TESTING FOR SMOKE CONTROL (1705.19)
26. ___ SEALING OF MASS TIMBER (1705.20)
27. ___ OTHER INSPECTIONS AS REQUIRED BY THE DESIGN
PROFESSIONAL OR THE BUILDING OFFICIAL (1705.1.1).
STATEMENT OF SPECIAL
INSPECTIONS
G. ANGULAR
H. 3" MAX PARTICLE SIZE
11. FREE DRAINING GRAVEL MATERIAL SHALL MEET THE FOLLOWING REQUIREMENTS
A. CLEAN, DURABLE, CRUSHED OR NATURAL GRAVEL
B. NON-EXPANSIVE
C. FREE OF FINES, CLAYS, AND ORGANIC MATERIAL
D. NOMINCAL PARTICLE SIZE : 3/8"
E. MAXIMUM PARTICLE SIZE : 1/2"
F. FINES CONTENT : 5% MAX PASSING NO. 200 SIEVE
G. SUB-ANGULAR OR ROUNDED PARTICLES ACCEPTABLE
12. PROTECT VAPOR BARRIER PUNCTURES DURING REPLACEMENT;
REPAIR BEFORE CONCRETE IS POURED
A naylor wentworth lund a r c h i t e c t s
NW
L P
RO
JE
CT
ISS
UE
DA
TE
DR
AW
ING
IS
SU
E
2 3 4 5 6
B
C
D
E
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce.
Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
ME
DIA
TIO
N
DATE REVISION
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
STRUCTURAL NOTES
A201
N O
T
FO
R C
O N
ST
R
U C
TI
naylor wentworth lund a r c h i t e c t s
NW
L P
RO
JE
CT
ISS
UE
DA
TE
DR
AW
ING
IS
SU
E
2 3 4 5 6
B
C
D
E
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce.
Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
ME
DIA
TIO
N
DATE REVISION
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
GYMNASIUM
DEMOLITION PLAN
DEMOLITION KEY NOTES
REMOVE AND DISCARD EXISTING WOOD FLOOR,
SLEEVES. REMOVE AND DISCARD 5" SLAB ON GRADE
DEMO ALL ASSOCIATED BLOCKING, FLOOR TO
EXISTING CONCRETE SLAB. ADJACENT WALLS THAT
REMAIN SHOULD BE KEPT FREE FROM DAMAGE. IF
DAMAGED OCCURS, PATCH AND REPAIR, FINISH TO
MATCH EXISTING FINISH.
CAREFULLY REMOVE ALL EXISTING THRESHOLDS AT
DOORS, FOR REINSTALLATION. SURROUNDING FLOOR
SHOULD BE KEPT FREE FROM DAMAGE. EXISTING
DOOR JAMB AND SLAB SHOULD BE KEPT FREE FROM
DAMAGE.
EXISTING BLEACHERS TO BE PROTECTED FROM
DUST AND DEBRIS. ALL ASSOCIATED ANCHORS CAN
BE DETACHED AS NEEDED TO MOVE AROUND FOR
INSTALLATION OF NEW FLOOR.
BASKETBALL STANDARDS TO BE PROTECTED FROM
DEMOLITION.
ALL EXISTING INTERIOR SIDE OF WALLS TO BE
PROTECTED. IF DAMAGED PATCH AND REPAIR,
FINISH TO MATCH ALL EXISTING FINISHES.
PROTECT DOORS AND METAL FRAMES FROM
DEBRIS AND DUST.
Scale: 1 1/2" = 1'
EXISTING FLOOR AND SUBGRADE FOR DEMOLITION TYPICALB3
B3 D101
N
DO NOT EXCAVATE
BELOW
TOP OF EXISTING
FOOTING
Scale: 1/4" - 1'
ENLARGED GYM FLOOR PLANA1
HATCH REPRESENTS
AREA FOR INTENDED
DEMOLITION
B3 D101
B3 D101
B3 D101
D101
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
PROVIDE COVERAGE FOR MECHANICAL GRILLES
PROVIDE COVERAGE FROM MEZZANINE FLOOR +
GYM DURING CONSTRUCTION
FRAME IN DOOR DURING CONSTRUCTION
PIRATES
MONT HARMON
1'-6" DIA. MIN.
3" 1'-9
5" CONCRETE FLOOR SLAB
ON MEMBRANE VAPOR BARRIER AND 4"
FREE DRAINING GRANULAR FILL
4" O.D. GROUND SLEEVE
NON - SHRINK GROUT
FLOORING AS SPECIFIED
HAND EXCAVATED AREA BELOW
FLOOR SLAB
5" TO 6" DIA.
4" DIA.
8" DIA.
5" DIA.
4 1/4" DIA.
4" O.D. GROUND SLEEVE
5" DIA. SLEEVE LID
8" DIA. SLEEVE RIM ATTACHED
TO FLOOR WITH SCREWS
FLOORING AS SPECIFIED
5" CONCRETE FLOOR SLAB
UNDER SLAB VAPOR RETARDER
A naylor wentworth lund a r c h i t e c t s
NW
L P
RO
JE
CT
ISS
UE
DA
TE
DR
AW
ING
IS
SU
E
2 3 4 5 6
B
C
D
E
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce.
Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
ME
DIA
TIO
N
DATE REVISION
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
A101
FINISH FLOOR
PLANN
Scale: 1/4" - 1'
FINISH FLOOR PLANA1
FINISH FLOOR PLAN KEY NOTES
RETURN EXISTING BLEACHERS TO SAME LOCATION
PRIOR OF REMOVAL. FIELD VERIFY
DOOR OPENING TAKEN FROM THE EXTERIOR FACE
OF THE NORTH WALL.
COURT STRIPING/GRAPHIC LOGOS TO MATCH FINISH
FLOOR PLAN.
C2 A201
C2 A201
B1 A201
B3 A201
C2 A201
C2 A201
N O
T
FO
R C
O N
ST
R
U C
TI
O
N
Scale: N.T.S
VOLLEYBALL ANCHOR DETAILA6
SECTION A
SECTION A
PAINTED SCHOOL GRAPHIC.
HATCH REPRESENTS STAINED FINISH
ELECTRIC MOTORIZED OVERHEAD DOOR
SCHOOL DISTRICT TO PROVIDE POWER
naylor wentworth lund a r c h i t e c t s
NW
L P
RO
JE
CT
ISS
UE
DA
TE
DR
AW
ING
IS
SU
E
2 3 4 5 6
B
C
D
E
CA
RB
ON
SC
HO
OL
DI
ST
RIC
T
Pri ce.
Ut ah
.41
BID
SE
T
JA
NU
AR
Y 2
MO
NT
HA
RM
ON
SL
AB
RE
ME
DIA
TIO
N
DATE REVISION
CARBON SCHOOL DISTRICT
251 WEST 400 NORTH
PRICE, UT 84501
DETAILS
8" DIAMETER BOLT AT 32" OC MAX,
POWDER COATED
12" MAX FROM FLOOR
5" REINFORCED SLAB W #4
AT 18" OC EACH WAY
8" DIA. THROUGH
BOLT AT 32" OC MAX,
POWDER COATED
DO NOT EXCAVATE BELOW
TOP OF FOOTING
Scale: 1/2" = 1'-0" EXTERIOR ELEVATIONA3Scale: 1/2" = 1'-0"
INTERIOR ELEVATIONA2
Scale: 3/4" = 1'-0"
WALL SECTIONB1
Scale: 1 1/2" = 1'-0"
OVER HEAD HEAD DETAILC1
Scale: 1 1/2" = 1'-0"
OVER HEAD SILL DETAILB2
8" DIA. THROUGH BOLT
AT 32" OC MAX,
POWDER COATED
Scale: 3" = 1'-0"
JAMB DETAILB3
L6X6X5/16 REQ'D
EACH SIDE,
POWDER COATED
8" DIAMETER BOLT AT 32" OC MAX,
POWDER COATED
L6x6x5/16 REQ'D, POWDER COATED
L8x6x7/16 REQ'D, POWDER COATED
CUT LEG ONE SIDE
OF ANGLE FOR TIGHT
FIT AROUND WALLS2 - 12
CUT LEG ONE SIDE OF
ANGLE FOR TIGHT FIT
AROUND WALLS
2 - 12
CONTRACTOR TO VERIFY LOCATION
OF THE THROUGH BOLT DOES NOT
INTERFERE WITH REINFORCING IN
EXISTING CONCRETE BEAM.
CONTACT E.O.R IF SHOWN
DIMENSION INTERFERES WITH
EXISTING REINFORCING
Scale: 1" = 1'-0"
SLAB ON GRADE DETAIL TYPICALC2
VAPOR BARRIER
3' STRUCTURAL FILL
5" REINFORCED CONCRETE SLAB
W/ #4 18" OC EACH WAY
3" GRAVEL FILL
DO NOT EXCAVATE BELOW
TOP OF EXISTING FOOTING
VAPOR BARRIER
Scale: 1/2" = 1'-0"
ENLARGED PLAN OF OPENING A1
B1 A201
A201 B3
09.64.A -
08.33.23 -
05.12.B -
05.12.A -
03.30.A -
EXISTING
CONCRETE
BEAM
5/8" DIA. THROUGH
BOLT, POWDER COATED
L6x6x5/16 STEEL ANGLE.
PREP FOR PAINT BY
09 9123. COLOR TO BE
SELECTED BY ARCHITECT,
POWDER COATED
10'-2" INSULATED OVERHEAD
COILING DOOR
EXISTING MASONRY WALL
BEYOND. KEEP FREE FROM
DAMAGE
WOOD FLOORING SYSTEM
5" REINFORCED CAST-IN-PLACE
CONCRETE FLOOR SLAB. OVER 4"
FREE DRAINING GRAVEL ON
VAPOR BARRIER
EXISTING CONCRETE FOOTING
AND FOUNDATION WALL
05.12.A - WOOD FLOOR RUBBER
BASE WITH AIR VENTS
07.92.A - CONTINUOUS ELASTOMERIC
SELANT
08.33.A - 4" ALUMINUM THRESHOLD
EXISTING MASONRY
WALL. KEEP FREE
FROM DAMAGE
KEY VALUE NOTE
03.30.A 5" POWDER COATEDREINFORCED CONCRETE ON 4" DRAINING GRAVEL
W/ VAPOR BARRIER
05.12.A L6x6x5/16 STEEL ANGLE. POWDER COATED COLOR TO BE SELECTED BY
ARCHITECT
05.12.B 5/8" DIA. THROUGH BOLT, POWDER COATED
07.92.A CONTINUOUS ELASTOMERIC SELANT
08.33.23 10'-2" INSULATED OVERHEAD COILING DOOR
08.33.A 4" ALUMINUM THRESHOLD
A2
A201
BOTTOM OF FOOTING
96' - 8"
FINISH FLOOR LEVEL
100' - 0"
TOP OF OPENING
110' - 2"
08.33.23 08.33.23
05.12.A 05.12.A
12" MAX FROM FLOOR
A3
A201
EXISTING
MASONRY
WALL
3' STRUCTURAL FILL
3'-0"
EXISTING CONCRETE
FOUNDATION WALL
EXISTING CONCRETE FOUNDATION
WALL
1 12" MIN.
TYP.
1 12" MIN. TYP.
Scale: 1 1/2" = 1'-0"
TYPICAL JOINT DETAILSB4
JOINT SEALANT
ONE LAYER OF
#30 FELT
4" DIAMOND DOWEL AT
24" OC, OR APPROVED
EQUAL
CUT REBAR AT EACH
CONTROL JOINT
EXPANSION JOINT
EXPANSION JOINT
ISOLATION JOINT
CONSTRUCTION JOINT (CONTROL TYPE) IF SEPARATE POURS OCCUR
CONTROL JOINT
EXPANSION JOINT
EXPANSION JOINT
2" CLOSED CELL
EXPANSION JOINT
MATERIAL
FIRST POUR SECOND POUR
SAWCUT OR
PREFORMED PLASTIC
STRIP
#3 BAR AT 16" X 36"
CENTERED AT CONTROL JOINT.
LARGER BARS OR TIGHTER
SPACING NOT ALLOWED
8"
THICK (T)
6"
T/4
A201
N O
T
FO
R C
O N
ST
R
U C
TI
| Sheets and Views |
| G001 - COVER SHEET |
| A100 - OVERALL |
| D101 - GYM DEMO PLAN |
| A201 - STRUC NOTES |
| A101 - FINISH FLOOR PLAN |
| A201 - GYM DETAILS |
File details come from the government source that posted it. Updated .