2-Lot 12-Proposed Waterline (2026-08-07).pdf

PDF 233 KB Posted

Attached to
Highridge Business Park Project
Solicitation number
Not on record
Issued by
Somerset County, Pennsylvania

About this file

This is a proposed waterline design drawing for Lot 12 of the Highridge Business Park project developed by the Schuylkill Economic Development Corporation (SEDCO) in Foster Township, Schuylkill County, Pennsylvania. The project involves the installation of approximately 180 linear feet of 42-inch high-density polyethylene (HDPE) pipe at a 1.4% grade, along with a 12-inch water service line extending approximately 155 linear feet that includes an open cut section beneath existing gas and sewer infrastructure. The design incorporates a wet tap connection to the existing water main, a meter pit with a 12-inch water service cap, water valve installation, and a future connection stub extending 100 feet west with appropriate thrust blocks and pipe clearances. The drawing includes a cross-sectional profile (Section L-L) showing existing utility locations and depth requirements, with pipe cover depths ranging from 4 to 5 feet and 18-inch clearances maintained from other utilities. The design was prepared by WJ P Engineers of Pottsville, Pennsylvania, with revisions completed on August 5 and August 7, 2026, following review meetings with the Schuylkill County Municipal Authority (S.C.M.A.).

All work shall be performed in accordance with S.C.M.A. standards and specifications, utilizing Class 54 zinc-coated ductile iron pipe, fittings, and appurtenances. The tapping sleeve, valve, and wet tap connection must be completed by S.C.M.A., while all bends require thrust blocks and traffic control shall conform to PennDOT standards. Road restoration must match existing conditions, and all valves shall be installed as open right. The project was designed by the S.C.M.A. and is part of the larger Highridge Business Park development for which sealed proposals were due by September 7, 2026.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

FM

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

G G

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W W W W W W W W W W W W W W W W W

W

W

W W

W W

W W

W W

W W

W W

W

F:\0473\Lot 12\0473-1 - Lot 12.dwg, 8/7/2026 1:56:03 PM, DWG To PDF.pc3

AutoCAD SHX Text

180 LF 42" HDPE @ 1.4%

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PPL 39093 S 50668

AutoCAD SHX Text

12 WET" TAP

AutoCAD SHX Text

12" WATER SERVICE CAP

AutoCAD SHX Text WATER SERVICE: OPEN CUT UNDER GAS/ GRAVITY SEWER/FORCE SEWER TOTAL LENGTH: APPROX. 155 LF

AutoCAD SHX Text

METER PIT

AutoCAD SHX Text

C/L OF DRIVEWAY LANE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FUTURE

AutoCAD SHX Text 16'

AutoCAD SHX Text 8'

AutoCAD SHX Text L

AutoCAD SHX Text L

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

SECTION L-L VERTICAL SCALE: 1"=10' HORIZONTAL SCALE: 1"=10' (LOOKING WEST)

AutoCAD SHX Text

EXISTING GRADE

AutoCAD SHX Text

EXISTING FORCE MAIN

AutoCAD SHX Text

EXISTING SEWER LINE ELEV: 1581.4

AutoCAD SHX Text

EXISTING GAS LINE

AutoCAD SHX Text

EXISTING WATER LINE

AutoCAD SHX Text

PROPOSED DRIVWAY

AutoCAD SHX Text

KEYSTONE BOULEVARD

AutoCAD SHX Text

PROPOSED WATER VALVE

AutoCAD SHX Text

42" PIPEELEV: 1083.5 INSTALLED AFTER WATER LINE

AutoCAD SHX Text

EXISTING SWALE

AutoCAD SHX Text

PROPOSED 12" WATER SERVICE

AutoCAD SHX Text

EDGE OF DRIVEWAY

AutoCAD SHX Text

12" PIPE

AutoCAD SHX Text

12" CAP AT FUTURE METER PIT

AutoCAD SHX Text PROPOSED 12" WATER SERVICE w/ TEEEXTENDS 100' WEST

AutoCAD SHX Text

18" PIPE CLEARANCE

AutoCAD SHX Text

18" PIPE CLEARANCE

AutoCAD SHX Text

5' PIPE COVER

AutoCAD SHX Text

FUTURE METER PIT

AutoCAD SHX Text

RESTORE PAVEMENT SECTION

AutoCAD SHX Text

5' COVER

AutoCAD SHX Text

18" PIPE CLEARANCE

AutoCAD SHX Text

4' COVER

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

APPROVED BY

AutoCAD SHX Text

DRAWN BY

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

BY

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REVISION

AutoCAD SHX Text Engineers

AutoCAD SHX Text www.wjpengineers.com

AutoCAD SHX Text 1406 Laurel Boulevard - Pottsville, PA 17901

AutoCAD SHX Text Phone (570) 622-4550 Fax (570) 628-4445

AutoCAD SHX Text

SCHUYLKILL ECONOMIC DEVELOPMENT CORPORATION

AutoCAD SHX Text

PROPOSED COMMERCIAL/INDUSTRIAL

AutoCAD SHX Text

LOT 12

AutoCAD SHX Text

FOSTER TOWNSHIP

AutoCAD SHX Text

SCHUYLKILL COUNTY, PA

AutoCAD SHX Text 07/23/26

AutoCAD SHX Text 1"=10'

AutoCAD SHX Text

CMP

AutoCAD SHX Text

RNY

AutoCAD SHX Text

0473-WS

AutoCAD SHX Text

PROPOSED WATER SERVICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 08/05/26

AutoCAD SHX Text

REVISED PER MEETING WITH S.C.M.A.

AutoCAD SHX Text

CMP

AutoCAD SHX Text

AutoCAD SHX Text 08/07/26

AutoCAD SHX Text

REVISED PER S.C.M.A. REVIEW

AutoCAD SHX Text

CMP

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text

RICHARD N. YUTKO

AutoCAD SHX Text

ENGINEER

AutoCAD SHX Text No.038152-E

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text V

AutoCAD SHX Text L

AutoCAD SHX Text Y

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

PROFESSIONAL

AutoCAD SHX Text

REGISTERED

AutoCAD SHX Text O

AutoCAD SHX Text C

AutoCAD SHX Text O

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text A

AutoCAD SHX Text W

AutoCAD SHX Text T

AutoCAD SHX Text H

AutoCAD SHX Text

%%UGRAPHIC SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text PLAN NOTES: : WATER SERVICE DESIGN BY S.C.M.A. ALL WORK IN ACCORDANCE WITH S.C.M.A. STANDARDS. TAPPING SLEEVE AND VALVE, WET TAP TO BE COMPLETED BY S.C.M.A. ALL BENDS SHALL HAVE THRUST BLOCKS. THE STUB TO THE WEST SHALL ALSO HAVE A THRUST BLOCK. PLEASE NOTE ALL VALVES SHALL BE OPEN RIGHT. MATERIAL SHALL BE CLASS 54 ZINC COATED; DUCTILE IRON PIPE, FITTINGS & APPURTENANCES. OPEN CUT CONSTRUCTION, ALL TRAFFIC CONTROL PER PENNDOT STANDARDS. ROAD RESTORATION TO MATCH EXISTING.

AutoCAD SHX Text

PLAN VIEW SCALE: 1"=10'

AutoCAD SHX Text

PLAN VIEW SCALE: 1"=10'

File details come from the government source that posted it. Updated .