2-G3135-01 Released For Bid.pdf
PDF 37 MB Posted
- Attached to
- Station 2 Expansion Contract No. 2026-01
- Solicitation number
- Not on record
- Issued by
- Allegheny County, Claysville Borough, Pennsylvania
About this file
This file is a comprehensive set of architectural and engineering drawings and specifications for the Station 2 Expansion Contract No. 2026-01 project for the Imperial Volunteer Fire Department in Findlay Township, Allegheny County, Pennsylvania. The project involves the demolition of an existing 1,967-square-foot three-bay garage and construction of a new 4,840-square-foot pre-engineered metal building addition to the north of the existing office space, which will remain operational. The scope of work includes selective demolition of the existing garage structure, closure of pass-through openings in the common CMU block wall between the existing spaces, construction of a new metal frame building with split-face masonry block walls, installation of new mechanical systems (furnace, air conditioner, hot water heater, and ductwork), replacement of the existing roof with upgraded insulation, electrical service upgrades to support the expansion, plumbing and HVAC system installation, and site work including concrete slabs, foundations, and stormwater management. The project has an expected duration of 210 days, with a non-mandatory pre-bid conference scheduled for Wednesday, June 24, 2026, at 10:00 A.M. at the substation location (28 Matchette Road, Clinton, PA 15026), and sealed bids due electronically via PennBid by Tuesday, July 7, 2026, at 1:00 P.M. local time.
The project is subject to the Pennsylvania Prevailing Wage Act of 1961, Title VI and other applicable Civil Rights Act provisions, Department of Labor Equal Opportunity Clause requirements, Executive Orders 11625 and 12138 regarding minority and female business enterprise utilization, Section 504 of the Rehabilitation Act of 1973, Americans with Disabilities Act compliance, and the Allegheny County MBE/WBE Program with goals of 13 percent minority and 2 percent female business enterprise participation. Bidding documents are available at no cost through the PennBid program (pennbid.bonfirehub.com). All official notifications, addenda, and bidding documents will be distributed exclusively through the designated website. The drawings specify multiple building systems including 24-gauge standing seam roofing, 26-gauge wall and roof liner panels in white, split-face masonry block walls in buckskin tan, four overhead bay doors with motorized operators, mechanical systems with radiant tube heaters and ceiling-mounted exhaust fans, electrical service with a 200-amp main distribution panel and 100-amp branch circuit panel, emergency lighting and exit fixtures, and site infrastructure including bollard protection, trench drains, and concrete pavements with specified finishes and control joints.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-3135-01 2026-01 Bid Specs.pdf | ||
| 3-3135-01 2026-01 Addendum 1 06.11.26.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Drawing No.
Sheet No.
5313 Campbells Run Road, Suite 100 Pittsburgh, PA 15205
Phone: 412.494.0510 Fax: 412.494.0426 info@klhengineers.com
KLH
ENGINEERS, INC
ALLEGHENY COUNTY, PENNSYLVANIA
SCALE: 1" = 2000'
PROJECT LOCATION
G1 Copyright © 2026 KLH Engineers, Inc., All Rights Reserved Worldwide.
No part of this document may be reproduced or transmitted in any form, by any means without written permission, except for brief excerpts in reviews or analysis.
TITLE SHEET
EXISTING BUILDING DEMO PLAN
EXISTING BUILDING DEMO ELEVATIONS
BUILDING PLAN
BUILDING ELEVATIONS
BUILDING ELEVATIONS
TS.01
A.01 A.02 A.03 A.04 A.05 of 1
Order No.
IMPERIAL VOLUNTEER FIRE DEPARTMENT
DESCRIPTIONDWG. NO.SHEET NO.
DRAWING LIST
LOCATION MAP
CONTRACT NO. 2026-01
STATION 2 EXPANSION
3135-01
N
RELEASED FOR BID
MAY 2026
BUILDING SECTIONS
DETAILS
A.06 A.07
A.08
CONCRETE NOTES
FOUNDATION PLAN
FOUNDATION DETAILS
A.09
S.01 S.02 S.03 S.04
TYPICAL CMU WALL DETAILS
S.05 S.06 S.07
GENERAL
LINE SAFETY
EGRESS PLAN1 of 1 LS.01
ARCHITECTURAL
DETAILSA.10
DETAILS
STRUCTURAL
FOUNDATION DETAILS
FOUNDATION DETAILS
FOUNDATION DETAILS
MECHANICAL
MECHANICAL PLAN AND SCHEDULEM.011 of 1
ELECTRICAL
ELECTRICAL FLOOR PLANE.01
ELECTRICAL SCHEDULES AND DETAILS
E.02
E.03
PLUMBING
PLUMBING PLAN, SCHEDULES,
AND SCHEMATICS
P.011 of 1
DOOR, WINDOW, AND ROOM
FINISH SCHEDULES
ELECTRICAL SCHEMATICS AND
DIAGRAMS
DESCRIPTIONFO #SHEET NO.
DRAWING LIST
BUILDING MANUFACTURER DRAWINGS
TITLE SHEET
SPECIFICATIONS
ANCHOR BOLT PLAN
RIGID FRAME REACTIONS
ENDWALL REACTIONS, DESIGN
CRITERIA
28039
ANCHOR BOLT DETAILS
ROOF FRAMING
ROOF PANEL LAYOUT
RIGID FRAME #1
RIGID FRAME #2
RIGID FRAME #3
FRONT SIDEWALL FRAMING
BACK SIDEWALL FRAMING
LEFT ENDWALL FRAMING
RIGHT ENDWALL FRAMING
LINER PANER LAYOUT
ROOF LINER PANEL
DETAIL PAGE #1
DETAIL PAGE #2
DETAIL PAGE #3
DETAIL PAGE #4
DETAIL PAGE #5
28039 28039 28039
28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039 28039
DESCRIPTIONDWG. NO.SHEET NO.
DRAWING LIST
DEVELOPMENT PLANS
TITLE SHEET
EXISTING CONDITIONS
CONSTRUCTION PLAN
LANDSCAPE AND PHOTOMETRIC PLAN
SITE DETAILS
EROSION AND SEDIMENTATION CONTROL PLANS
EROSION AND SEDIMENTATION
CONTROL PLAN
EROSION AND SEDIMENTATION
CONTROL NOTES
EROSION AND SEDIMENTATION
CONTROL DETAILS
POST CONSTRUCTION STORMWATER
MANAGEMENT PLANS
PCSM PLAN
PCSM DETAILS
578-004-1 578-004-2 578-004-3 578-004-4
578-004-ES1
578-004-ES2
578-004-ES3
1 of 2 578-004-PCSM1
578-004-PCSM2
AutoCAD SHX Text S:\Active Clients\3135 Imperial VFD\3135-01 Imperial VFD\Dwg\G3135-01-001 - G1.dwg 5/21/2026 8:16 AM Plotted By: Elmer Danziger 5/21/2026 8:16 AM Plotted By: Elmer Danziger5/21/2026 8:16 AM Plotted By: Elmer Danziger Plotted By: Elmer DanzigerElmer Danziger
104 BROADWAY STREET
CARNEGIE, PA 15106
412.886.5000 www.redconengineering.com
JOB:
DWG:
TS.01
DATE:
REV. DATEDESCRIPTION
SEAL:
DRAWING STATUS:
BID1 05/12/26REVISED AS SHOWN
Know what's below.
before you dig.Call
R
USGS LOCATION MAP
NOT TO SCALE
REFERENCE ONLY
SITE VICINITY MAP
NOT TO SCALE
REFERENCE ONLY
(GOOGLE MAPS)
SITUATE IN:
FINDLAY TOWNSHIP
ALLEGHENY COUNTY
PENNSYLVANIA
CLIENT:
IMPERIAL VOLUNTEER FIRE DEPTARTMENT
111 PINE STREET
IMPERIAL, PA 15126
0329-001
3/11/24
SUB-STATION
BUILDING EXPANSION
28 MATCHETTE RD.
CLINTON, PA 15026
(ALLEGHENY COUNTY)
SITE LOCATION
IMPERIAL VOLUNTEER
FIRE DEPARTMENT SITE LOCATION
PAGE NO.
28039
FO#
TITLE SHEET
DESCRIPTION
1 OF 21 SPECIFICATIONS
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
28039
ANCHOR BOLT PLAN
RIGID FRAME REACTIONS
ENDWALL REACTIONS, DESIGN CRITERIA
ANCHOR BOLT DETAILS
ROOF FRAMING
ROOF PANEL LAYOUT
RIGID FRAME #1
FRONT SIDEWALL FRAMING
BACK SIDEWALL FRAMING
LEFT ENDWALL FRAMING
RIGHT ENDWALL FRAMING
LINER PANEL LAYOUT
ROOF LINER PANEL
DETAIL PAGE #1
DETAIL PAGE #2
RIGID FRAME #2
RIGID FRAME #3
DETAIL PAGE #3
DETAIL PAGE #4
DETAIL PAGE #5
TS.01
DWG. NO.
TITLE SHEET
DESCRIPTION
S.01
EXISTING BUILDING DEMO PLAN
S.02
EXISTING BUILDING DEMO ELEVATIONS
S.03
BUILDING PLAN
S.04
S.05
S.06
S.07
ELEVATIONS
ELEVATIONS
BUILDING SECTIONS
DOOR, WINDOW AND ROOM FINISH SCHEDULES
M.01
P.01
DETAILS
DETAILS
E.01
EGRESS PLAN
A.01
A.02
A.03
A.04
A.05
A.06
A.07
A.08
A.09
LS.01
CONCRETE NOTES
FOUNDATION PLAN
FOUNDATION DETAILS
FOUNDATION DETAILS
FOUNDATION DETAILS
FOUNDATION DETAILS
TYPICAL CMU WALL DETAILS
MECHANICAL PLAN AND SCHEDULE
PLUMBING PLAN, SCHEDULE AND SCHEMATICS
ELECTRICAL FLOOR PLAN
DRAWING LIST
E.02 ELECTRICAL SCHEMATICS AND DIAGRAMS
E.03 ELECTRICAL SCHEDULES AND DETAILS
GENERAL
ARCHITECTURAL
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
BUILDING MANUFACTURER DRAWINGS
REFERENCED CODES AS ADOPTED UNDER PA UCC
2018 INTERNATIONAL BUILDING CODE WITH AMENDMENTS
2018 INTERNATIONAL ENERGY CONSERVATION CODE
NATIONAL ELECTRIC CODE, NFPA 70-2017
2018 INTERNATIONAL FIRE CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL PLUMBING CODE
LIFE SAFETY
CODE ANALYSIS
OCCUPANCY CLASSIFICATION AND USE
CONSTRUCTION TYPE
ALLOWABLE HEIGHT
ACTUAL HEIGHT
ALLOWABLE AREA
ACTUAL AREA
CODE ITEM CLASSIFICATION
ALLOWABLE NUMBER OF STORIES
ACTUAL NUMBER OF STORIES
PRIMARY STRUCTURAL STEEL
EXTERIOR BEARING WALLS
INTERIOR BEARING WALLS
EXTERIOR NON-BEARING WALLS
INTERIOR NON-BEARING WALLS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
IBC SECTION 304.1, 311.3
IBC TABLE 601 & 602
IBC TABLE 504.3
IBC TABLE 506.2
CODE REFERENCE
IBC TABLE 504.4
IBC TABLE 601
IBC TABLE 602
S-2, NON-SPRINKLERED
IIB
55'-0"
28'-5"
26,000 SQUARE FEET
4,840 SQUARE FEET
NEW GARAGE ADDITION
3 STORIES
1 STORY
0 - HOURS REQUIRED
B, NON-SPRINKLERED
IIIB
40'-0"
18'-8"
9,000 SQUARE FEET
1,154 SQUARE FEET
EXISTING BUILDING
2 STORIES
1 STORY
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
IBC TABLE 601
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
2 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
0 - HOURS REQUIRED
AUTOMATIC SPRINKLER SYSTEMS IBC SECTION 903 NOT REQUIRED NOT REQUIRED
MEANS OF EGRESS
ALLOWABLE EXIT ACCESS TRAVEL DISTANCE IBC TABLE 1017.2 300'-0", NON-SPRINKLERED
ACTUAL EXIT ACCESS TRAVEL DISTANCE 102'-0"
200'-0", NON-SPRINKLERED
42'-6"
FIRE RATINGS
FIRE ALARM DETECTION SYSTEMS IBC SECTION 907 NOT REQUIRED NOT REQUIRED
NOTE: SMOKE DETECTORS, FIRE EXTINGUISHERS AND GAS DETECTORS BY OWNER.
THIS PROJECT IS AN EXPANSION OF THE EXISTING IMPERIAL VOLUNTEER FIRE DEPARTMENT SUB-STATION IN
FINDLAY TOWNSHIP, ALLEGHENY COUNTY, PENNSYLVANIA. THE EXISTING BUILDING IS COMPRISED OF TWO AREAS:
A 1,967 SQUARE FEET, THREE-BAY GARAGE AND A 1,180 SQUARE FEET OFFICE SPACE. IN THE EXISTING CONDITION, THE TWO SPACES ARE OPEN TO EACH OTHER THROUGH THREE OPENINGS IN THE CONCRETE MASONRY UNIT
(CMU) COMMON WALL. AS PART OF CONSTRUCTION, THE THREE-BAY GARAGE WILL BE DEMOLISHED, AND THE
OFFICE SPACE WILL REMAIN. THE OPENINGS WILL BE CLOSED USING A COMBINATION OF NEW CMU AND DOORS. A
NEW GARAGE ADDITION OF A 4,840 SQUARE FEET PRE-ENGINEERED METAL BUILDING WILL BE BUILT TO THE NORTH
OF THE OFFICE SPACE. PER THE 2018 EXISTING BUILDING CODE (IEBC), CHAPTER 11, AN ADDITION TO A BUILDING
SHALL COMPLY WITH THE INTERNATIONAL CODES AS ADOPTED FOR NEW CONSTRUCTION WITHOUT REQUIRING
THE EXISTING BUILDING TO COMPLY WITH ANY REQUIREMENTS OF THOSE CODES. WHERE AN ADDITION IMPACTS
THE EXISTING BUILDING, THAT PORTION SHALL COMPLY WITH THE CODE. FURTHERMORE, ANY REPAIR OR
ALTERATION WORK WITHIN AN EXISTING BUILDING TO WHICH AN ADDITION IS BEING MADE SHALL COMPLY WITH
THE APPLICABLE REQUIREMENTS FOR THE WORK AS CLASSIFIED IN CHAPTER 6 OF THE IEBC.
THE SCOPE OF WORK FOR THE EXISTING BUILDING INCLUDES A NEW ROOF WITH UPGRADED INSULATION AND NEW
MECHANICALS (HOT WATER HEATER, FURNACE, AIR CONDITIONER, NEW DUCT WORK). PER CHAPTER 6 OF THE
IEBC, REROOFING CONSTITUTES A LEVEL 1 ALTERATION OF THE EXISTING SPACE AND WILL COMPLY WITH SECTION
705. PER CHAPTER 6 OF THE IEBC, THE ADDITION OF HVAC EQUIPMENT CONSTITUTES A LEVEL 2 ALTERATION OF
THE EXISTING SPACE AND WILL COMPLY WITH SECTION 808. THE PROPOSED ALTERATIONS FALL UNDER THE
EXCEPTIONS LISTED IN SECTION 305 OF THE IEBC FOR ACCESSIBILITY FOR EXISTING BUILDINGS.
SCOPE OF WORK
2018 INTERNATIONAL EXISTING BUILDING CODE
DETAILSA.10
UTILITY PROVIDER
COLUMBIA GAS OF PENNSYLVANIA
DUQUESNE LIGHT COMPANY
COMPANY NAME
GAS
ELECTRIC
SERVICE TYPE
JUSTIN COLES,
DEVELOPMENT MANAGER
RICK JOHN
CONTACT PERSON
724-470-8341
412-216-6521
PHONE NUMBER NOTES
CONTRACTOR TO CONTACT COLUMBIA GAS
IMMEDIATELY UPON AWARD TO COORDINATE NEW
METER INSTALLATION
WORK ORDER NO. 6908630687
ENGINEERING NO. 1037685
METER NO. 75 992 609
ACCOUNT NO. 6908-630-000
AutoCAD SHX Text
MARTY J. MICKO
AutoCAD SHX Text
PROFESSIONAL
AutoCAD SHX Text
REGISTERED
AutoCAD SHX Text
PE-049845-E
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text Y
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text V
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text
NO.
WOMEN MEN
MECHANICAL
ROOM
ELECTRICAL
ROOMOFFICE
STORAGE
KITCHEN
ENTRY
'-0
N
E W
B U
IL
D
IN
G
A
E
'-0
" o E
X
IS
TI
N
G B
U
IL
D
IN
G
NEW
JANITOR
CLOSET
GARAGE
EXIT
E X
IT
TRAVEL DISTANCE
(��'-0")
TRAVEL DISTANCE
(�02'-0")
(2
-6
TRAVEL DISTANCE
(40'-0")
TR
A
V E
L D
IS
TA
N C
E
0'
-0
TR
A
V E
L D
IS
TA
N C
E
E X
IT
E
X
IT
TRAVEL DISTANCE
(40'-0")
TRAVEL
DISTANCE
(42'-6")
TRAVEL DISTANCE
(��'-6")
TRAVEL
DISTANCE
(�4'-0")
�0'-�"
NEW BUILDING
� � 2�'-4" o
EXISTING BUILDING
CONCRETE PAVEMENT
N
SCALE:
0329-001
JOB:
DWG:
LS.01
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
E
G R
E S
S P
L A
N
3/11/24
DATE:
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
DGN:
DWN:
CHK:
APP:
BKK
BKK
JRE
EAH
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
EGRESS PLAN�
LS�0� SCALE: ��4" � �'-0"
/1 2/
R
E V
IS
E
D A
S S
H O
W N
WH
MECHANICAL
ROOM
ELECTRICAL
ROOMOFFICE
STORAGE
KITCHEN
ENTRY
�0'-0" o
(FIELD VERIFY)
PORTION TO REMAIN
'-0
" o (F
IE
LD
V E
R
IF
Y
P O
R
TI
O N
T O
R E
M A
IN
EXISTING GARAGE
DEMO EXISTING CMU BLOCK WALL
AND WOOD TRUSS FRAMED GARAGE
'-0
" o (F
IE
LD
V E
R
IF
Y
G A
R A
G E
D E
M O
�0 '-0
D
E M
O
�4'-0"
(FIELD VERIFY)
GARAGE DEMO
�0'-0" o
(FIELD VERIFY)
PORTION TO REMAIN
�0'-0"
(FIELD VERIFY)
GARAGE DEMO
DEMO EXISTING CONCRETE APRON
CMU BLOCK COMMON
WALL TO REMAIN
FA
C
E O
F C
O M
M O
N W
A
LL
FA
C
E O
F C
O M
M O
N W
A
LL
EXISTING BUILDING
PORTION TO REMAIN
EXISTING BUILDING
PORTION TO REMAIN
HEATER
PLUMBER TO CAP OFF�ABANDON
EXISTING GAS LINE TO ALL
GARAGE HEATERS�
HEATER
OWNER WANTS
TO SAVE THE (�)
GARAGE DOORS
DEMO EXISTING GARAGE
SLAB AND FOUNDATIONS
SAW CUT SLAB ALONG THE LINE OF
THE COMMON CMU BLOCK WALL
BETWEEN THE EXISTING SLAB TO
BE REMOVED
AND THE EXISTING
SLAB THAT WILL REMAIN�
SCALE:
0329-001
JOB:
DWG:
A.01
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
E
X
IS
T
IN
G B
U
IL
D
IN
G D
E M
O P
L A
N
3/11/24
DATE:
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
EXISTING BUILDING DEMO PLAN�
A�0� SCALE: ��4" � �'-0" N
BKK
BKK
JRE
EAH
/1 2/
R
E V
IS
E
D A
S S
H O
W N
EXISTING GARAGE E2UIPMENT NOTE:
CAREFULLY REMOVE THE (2) CEILING HEATERS
(�) GARAGE
DOORS
AND (�) GARAGE DOOR OPENERS� DO NOT DISCARD�
ALL REMOVED ITEMS SHALL REMAIN PROPERTY OF THE FIRE
DEPARTMENT� COORDINATE WITH CLIENT FOR ON SITE
STORAGE OR HANDOVER�
30'-0" ± (FIELD VERIFY)
BUILDING PORTION TO REMAIN
50'-0" (FIELD VERIFY)
GARAGE DEMO
FACE OF COMMON
BLOCK WALL
DEMO EXISTING CMU BLOCK WALL
AND WOOD TRUSS FRAMED GARAGE
REMOVE EXISTING
ASPHALT SHINGLES AND
REPAIR ANY DAMAGED
SHEATHING AS REQUIRED
IMPERIAL VOL. FIRE DEPT. SUB-STATION
OWNER TO REMOVE LETTERING
FROM EXISTING BUILDING AND
REINSTALL ON NEW BUILDING
A
A.10
REMOVE EXISTING TRUSS AT
THIS LOCATION AND REINSTALL
TRUSS 8" BACK FROM THE FACE
OF THE COMMON BLOCK WALL
8"
CUT EXISTING ROOF SHEATHING
BACK 8" FROM THE FACE OF THE
COMMON BLOCK WALL
REINFORCE FIRST 6 TRUSSES
FROM COMMON WALL FOR
ADDITIONAL SNOW LOAD SUPPORT
REMOVE EXISTING GLASS BLOCK
WINDOWS AND REPLACE WITH NEW
WINDOWS AS SHOWN ON THE
WINDOW SCHEDULE
30'-0" ± (FIELD VERIFY)
PORTION TO REMAIN
50'-0" (FIELD VERIFY)
GARAGE DEMO
DEMO EXISTING CMU BLOCK WALL
AND WOOD TRUSS FRAMED GARAGE
REMOVE EXISTING
ASPHALT SHINGLES AND
REPAIR ANY DAMAGED
SHEATHING AS REQUIRED
A
A.10
FACE OF COMMON
BLOCK WALLREMOVE EXISTING DOOR AND
REPLACE WITH NEW DOOR AS
SHOWN IN DOOR SCHEDULE
40'-0" (FIELD VERIFY)
GARAGE DEMO
DEMO EXISTING CMU BLOCK WALL
AND WOOD TRUSS FRAMED GARAGE
REMOVE EXISTING SIDING.
WALL SHEATHING UNDERNEATH
TO REMAIN. REPAIR ANY DAMAGED
SHEATHING AS REQUIRED.
40'-0" (FIELD VERIFY)
REMOVE EXISTING
ATTIC LOUVER
REMOVE
EXISTING
GUTTER
REMOVE
EXISTING
GUTTER
SCALE:
0329-001
JOB:
DWG:
A.02
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
E
X
IS
T
IN
G B
U
IL
D
IN
G D
E M
O E
L E
V A
T
IO
N S
3/11/24
DATE:
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
EXISTING WEST ELEVATION DEMO1
A.02 SCALE: 1/4" = 1'-0"
EXISTING EAST ELEVATION DEMO2
A.02 SCALE: 1/4" = 1'-0"
EXISTING NORTH ELEVATION DEMO3
A.02 SCALE: 1/4" = 1'-0"
BKK
BKK
JRE
EAH
EXISTING SOUTH ELEVATION DEMO4
A.02 SCALE: 1/4" = 1'-0"
/1 2/
R
E V
IS
E
D A
S S
H O
W
WH
MECHANICAL
ROOM
ELECTRICAL
ROOMOFFICE
STORAGE
KITCHEN
ENTRY
�'-2"
�'-4"
2�'-�"
�0'-�"
NEW BUILDING
�4'-0" Y �4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0" Y �4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0" Y �4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0" Y �4'-0"
OVERHEAD DOOR
�'-4"
2'-0"
��'-�" ��'-�" 2�'-�"�'-0"
OVERHANG
�'-0"
OVERHANG
4' -0
'-0
'-0
N
E W
B U
IL
D
IN
G
-4
�2
'-0
'-0
-0
O
V E
R H
A N
G
2�'-�" ��'-�"�'-0"
OVERHANG
��'-�" 2�'-�"
2'-0"
4' -0
O
V E
R H
A N
G
2 � 4
A
B
C
E
� 2 � 4 � �'-0"
OVERHANG
-0
O
V E
R H
A N
G
E
2�'-4" o (FIELD VERIFY)
EXISTING BUILDING
'-0
" o (F
IE
LD
V E
R
IF
Y
E X
IS
TI
N G
B U
IL
D
IN
G
ROOF OVERHANG
EXISTING BUILDING
TO REMAIN
EXISTING BUILDING
CMU BLOCK WALL
(FACE OF COMMON WALL)
INSTALL FULL HEIGHT 26 GA
LINER SHEETING STARTING
AT 4'-0" ABOVE FINISHED FLOOR
NEW
JANITOR
CLOSET
GD1
D1
D2
GD1 GD1 GD1
CUT OUT EXISTING CMU
BLOCK PASS-THROUGH
OPENING TO CREATE JANITOR
CLOSET ENTRANCE� MATCH
EXISTING PASS-THROUGH
OPENING WIDTH�
BLOCK UP EXISTING
PASS-THROUGH OPENING�
D
'-0
-4
D3
D4
INSTALL NEW �6" DOOR
IN EXISTING BUILDING
OPENING
BLOCK UP OVERSI;ED OPENING
AS RE2UIRED� MATCH EXISTING�
�'-0"
NEW
OVERHANG
CONSTRUCT NEW �'-0"
OVERHANG WITH SOFFIT
ON ALL � SIDES OF
EXISTING BUILDING ROOF
-0
N
E W
O V
E R
H A
N G
-0
N
E W
O V
E R
H A
N G
�'-0"
NEW
OVERHANG
INTAKE LOUVER
(�'-0" SILL HEIGHT)
EXHAUST FAN ABOVE
(2�'-0" SILL HEIGHT)
0"
-0
L1
F1
�'-�"�'-4"
DOOR
�'-2"
�'-� ����6" 2'-� ���6"
WINDOW
�'-� ����6" �'-�� ����6" 2'-� ���6"
WINDOW
�'-�� ����6" �'-� ����6"2'-� ���6"
WINDOW
�'-� ����6"
�'-�� ����6" 2'-� ���6"
WINDOW
(WINDOW NOT SHOWN FOR CLARITY)
�'-�� ����6"
W1 W1 W1
W1
CONSTRUCT TWO NEW METAL
STUD-FRAMED WALLS WITH ���"
DRYWALL ON BOTH SIDES UP TO
THE EXISTING CEILING TO ENCLOSE
THE NEW JANITOR CLOSET�
6' -0
(FIELD VERIFY)
B
A�06
A
A�06
FULL HEIGHT SPLIT
FACE MASONRY
BLOCK WALL
4'-0" HEIGHT SPLIT FACE
MASONRY BLOCK WALL
WITH FULL HEIGHT 26 GA�
LINER SHEETING ABOVE
4'-0" HEIGHT SPLIT FACE
MASONRY BLOCK WALL
WITH FULL HEIGHT 26 GA�
LINER SHEETING ABOVE
4'-0" HEIGHT SPLIT FACE
MASONRY BLOCK WALL
WITH FULL HEIGHT 26 GA�
LINER SHEETING ABOVE
NOTE:
CEILING TO HAVE 26 GA�
ROOF LINER SHEETING ABOVE
INSTALL NEW �6" DOOR
IN EXISTING BUILDING
OPENING
BOLLARD (TYP�)
(SEE DETAIL ���S�06)
�'-4"
CL
W2W2
D5
REMOVE AND
REPLACE
EXISTING DOOR
REMOVE AND REPLACE
EXISTING GLASS
BLOCK WINDOWS
SCALE:
0329-001
JOB:
DWG:
A.03
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
B
U
IL
D
IN
G P
L A
N
3/11/24
DATE:
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
DGN:
DWN:
CHK:
APP:
BKK
BKK
JRE
EAH
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
BUILDING PLAN�
A�0� SCALE: ��4" � �'-0" N
BUILDING DESIGN INFORMATION
RISK CATEGORY: IV
ULTIMATE WIND SPEED: 122 MPH
COLLATERAL LOAD: 5 PSF
ROOF LIVE LOAD: 20 PSF
GROUND SNOW LOAD: 25 PSF
ROOF SNOW LOAD: 22 PSF
/1 2/
R
E V
IS
E
D A
S S
H O
W N
IMPERIAL VOL. FIRE DEPT. SUB-STATION1'-0"
OVERHANG
'-1
9/
B O
TT
O
M O
F O
V E
R H
A N
G
29'-4" ±
EXISTING BUILDING
(FIELD VERIFY)
5'-4" 14'-0" x 14'-0"
OVERHEAD DOOR
2'-4" 14'-0" x 14'-0"
OVERHEAD DOOR
14'-0" x 14'-0"
OVERHEAD DOOR
14'-0" x 14'-0"
OVERHEAD DOOR
5'-4"
24 GA. SEAM-LOK
STANDING SEAM ROOF
FULL HEIGHT
SPLIT FACE
MASONRY
BLOCK WALL
S-5 COLORGARD SNOW
RETENTION SYSTEM
2 3 4
1 5
2'-4" 2'-4" 2'-4" 2'-4" 2'-4"
21'-8"
80'-8"
NEW BUILDING
18'-8" 18'-8" 21'-8"
1'-0"
OVERHANG
EXHAUST
FAN
DOWNSPOUTS
TO CONNECT TO
UNDERGROUND
DETENTION
SYSTEM (TYP.)
BOLLARDS (TYP.)
REMOVE ASPHALT SHINGLES
FROM EXISTING ROOF AND
INSTALL NEW 24 GA. SEAM-LOK
STANDING SEAM ROOF TO
MATCH NEW BUILDING ADDITION
CONSTRUCT NEW
1'-0" OVERHANG
WITH SOFFIT ON
ALL 3 SIDES OF
EXISTING
BUILDING ROOF
GD1 GD1 GD1 GD1
GUTTER
GUTTER
'-0
E
A V
E E
IG
H
T
F1
8"
EDGE OF
EXISTING
BLOCK WALL
LETTERING
BY OWNER
C
S.07
D
S.07
E
S.07
H
S.07
B
S.07
F
S.07
A
S.07
F
S.07
TOP OF LIGHT
AT 14'-0"
SIM.
A
A.06
B
A.06
LOW PROFILE RIDGE
VENT FOR STANDING
SEAM ROOF, BY BUILDING
MANUFACTURER
NEW 26 GA. "R" PANEL
SHEETING TO MATCH NEW
BUILDING ADDITION
RV1
S-5 COLORGARD SNOW
RETENTION SYSTEM
C
A.10
E
A.10
B
A.10
4"
'-0
E
A V
E H
E
IG
H T
(F
IE
LD
V
E R
IF
Y
NATURAL GAS
GENERATOR
1'-0"
CONTROL
JOINT
CONTROL
JOINT
CONTROL
JOINT
CONTROL
JOINT
CONTROL
JOINT
CONTROL
JOINT
4'-0"
OVERHANG
40'-0" ±
EXISTING BUILDING
(FIELD VERIFY) 60'-0"
NEW BUILDING
20'-0"
1'-0"
OVERHANG
12" 4"
12" 4"
'-0
E
A V
E H
E
IG
H T
'-0
E
A V
E E
IG
H
T
EA
NEW 1'-0"
OVERHANG
'-0
E
A V
E H
E
IG
H T
(F
IE
LD
V
E R
IF
Y
'-1
9/
B O
TT
O
M O
F O
V E
R H
A N
G
INTAKE
LOUVER
CONDENSER
UNIT
26 GA. "R" PANEL
NEW 26 GA. "R" PANEL
SHEETING TO MATCH NEW
BUILDING ADDITION
L1
5' -0
S
IL
L
H E
IG
H
T
8'-10"3'-0"
LOUVER
18'-8"1'-4"
D
4' -0
S
P
LI
T
FA
C E
M A
S O
N R
Y B
LO
C
K
B
S.07
L2
FIXED
LOUVER
AC1
4"
NEW 1'-0"
OVERHANG
FURNACE COMBUSTION
AIR AND EXHAUST VENTS
ELECTRIC
METER
AUTOMATIC
TRANSFER SWITCH
GAS
METER CONTROL
JOINT
CONTROL
JOINT
J
S.07
GENERATOR
SCALE:
0329-001
JOB:
DWG:
A.04
E L
E V
A T
IO
N
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
WEST ELEVATION1
A.04 SCALE: 1/4" = 1'-0"
SOUTH ELEVATION2
A.04 SCALE: 1/4" = 1'-0"
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
BKK
BKK
JRE
EAH
/1 2/
R
E V
IS
E
D A
S S
H O
W N
1 1 1 1 1
NOTES:
1. THE CONTRACTOR SHALL DISCONNECT ANY EXISTING WIRING ON THE SOUTH WALL OF
THE BUILDING AND EITHER STORE OR TEMPORARILY SUPPORT UNTIL THE NEW SIDING
IS INSTALLED. AFTER THE NEW SIDING IS INSTALLED, REINSTALL WIRING WITH NEW
ANCHORS AND FASTENERS.
2. THE CONTRACTOR SHALL TEMPORARILY RELOCATE AND THEN REINSTALL THE
EXISTING RADIO ANTENNA IN ITS ORIGINAL LOCATION AFTER THE NEW ROOF PANELS
ARE INSTALLED. THE ANTENNA SHALL REMAIN OPERATIONAL THROUGHOUT
CONSTRUCTION. THE OWNER SHALL BE NOTIFIED IN ADVANCE AT LEAST 24 HOURS
WHEN THE ANTENNA MUST BE DISCONNECTED.
3. THE WIRING FOR THE EXTERIOR SIREN SHALL BE ROUTED THROUGH THE NEW SIDING
WITH A CONDUIT SLEEVE AND A WEATHERHEAD. FLASH AND SEAL AROUND THE
CONDUIT SLEEVE. THE SIREN SHALL REMAIN OPERATIONAL THROUGHOUT
CONSTRUCTION. THE OWNER SHALL BE NOTIFIED IN ADVANCE AT LEAST 24 HOURS
WHEN THE SIREN MUST BE DISCONNECTED.
4. GENERATOR SET CLEARANCES SHALL MEET THE FOLLOWING OR BE AS RECOMMENDED
BY THE MANUFACTURER OR NFPA 37:
a. BE AT LEAST 18 IN FROM THE FACE OF THE BUILDING BASED ON THE ORIENTATION
SHOWN (PARALLEL WITH THE BUILDING).
b. THE EXHAUST END SHALL BE AT LEAST 5 FT FROM ANY WINDOW, VENT, DOOR, OR
SIMILAR OPENING.
c. THE EXHAUST END SHALL BE AT LEAST 10 FT FROM FURNACE OR OTHER SIMILAR
INTAKES.
d. NO PLANTS, SHRUBS OR OTHER COMBUSTIBLES SHALL BE WITHIN 4 FT OF THE
EXHAUST END OR WITHIN 30 IN OF THE AIR INTAKE.
e. MAINTAIN 3 FT CLEARANCE FROM THE SERVICE DOOR ENTRANCE.
�2" 4"
�2" 4"
26 GA� "R" PANEL 4'-0"
OVERHANG
60'-0"
NEW BUILDING
�'-0"
OVERHANG
4' -0
S
P
LI
T
FA
C E
M A
S O
N R
Y B
LO
C
K
'-0
E
A V
E H
E
IG
H T
'-0
E
A V
E E
IG
H
T
�'-4" 4'-0"
20'-0"20'-0"
BC
�2'-�"
AE
20'-0"
EXHAUST FANF1
�6 " o
B O
TT
O
M O
F O
V E
R H
A N
G
D1 B
S�0�
F
S�0�
G
S�0�
A
S�0�
CONTROL
JOINT
CONTROL
JOINT
�'-0"
OVERHANG
�6
�6
B O
TT
O
M O
F O
V E
R H
A N
G
2�'-4" o
EXISTING BUILDING
(FIELD VERIFY)
24 GA� SEAM-LOK
STANDING SEAM ROOF
�'-4"
DOOR
4' -0
S
P
LI
T
FA
C E
M A
S O
N R
Y B
LO
C
K
�0'-�"
NEW BUILDING
2�4
2�'-�"��'-�"��'-�"2�'-�"
26 GA� "R" PANEL
�'-0"
OVERHANG
'-0
E
A V
E E
IG
H
T
EXHAUST
FAN
�'-� ����6" 2'-� ���6"
WINDOW
�'-� ����6"
�2
" S
IL
L H
E
IG
H T
(T Y
P
IC
A L)
�'-�� ����6" 2'-� ���6"
WINDOW
�'-�� ����6" �'-�� ����6" 2'-� ���6"
WINDOW
�'-�� ����6"
D2
REMOVE ASPHALT SHINGLES
FROM EXISTING ROOF AND
INSTALL NEW 24 GA� SEAM-LOK
STANDING SEAM ROOF TO
MATCH NEW BUILDING ADDITION
GUTTER
CONSTRUCT NEW
�'-0" OVERHANG
WITH SOFFIT ON
ALL � SIDES OF
EXISTING
BUILDING ROOF
DOWNSPOUTS
TO CONNECT TO
UNDERGROUND
DETENTION
SYSTEM (TYP�)
GUTTER
DOWNSPOUTS
TO CONNECT TO
UNDERGROUND
DETENTION
SYSTEM (TYP�)
�2 '-0
" o E
A V
E H
E
IG
H T
(F
IE
LD
V
E R
IF
Y
W1W1 W1 W1
F1
B
S�0�
�'-� ����6"2'-� ���6"
WINDOW
�'-� ����6"
A
A�06
B
A�06
W2W2
LOW PROFILE RIDGE
VENT FOR STANDING
SEAM ROOF
BY BUILDING
MANUFACTURER
RV1
NEW 26 GA� "R" PANEL
SHEETING TO MATCH NEW
BUILDING ADDITION
REMOVE EXISTING GLASS BLOCK
WINDOWS AND REPLACE WITH NEW
WINDOWS AS SHOWN ON THE
WINDOW SCHEDULE
HEATER
EXHAUST
HEATER
EXHAUST
HEATER
EXHAUST
S-� COLORGARD SNOW
RETENTION SYSTEM
S-� COLORGARD SNOW
RETENTION SYSTEM
D
A��0
4"
CONTROL
JOINT
CONTROL
JOINT
CONTROL
JOINT
D5
REMOVE AND
REPLACE
EXISTING DOOR
J
S�0�
SCALE:
0329-001
JOB:
DWG:
A.05
E L
E V
A T
IO
N
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
EAST ELEVATION�
A�0� SCALE: ��4" � �'-0"
NORTH ELEVATION2
A�0� SCALE: ��4" � �'-0"
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
BKK
BKK
JRE
EAH
1 1 1
/1 2/
R
E V
IS
E
D A
S S
H O
W
�2" 4"
�2" 4"
4' -0
S
P
LI
T
FA
C E
M A
S O
N R
Y
'-0
E
A V
E H
E
IG
H T
'-0
E
A V
E E
IG
H
T
INSTALL NEW �6" DOOR
NOTE:
FIELD MEASURE EXISTING
OPENING TO DETERMINE
IF CUSTOM DOOR SI;ING
IS RE2UIRED�
BLOCK UP OVERSI;ED
OPENING AS RE2UIRED�
MATCH EXISTING�
CUT OUT EXISTING CMU
BLOCK PASS-THROUGH
OPENING TO CREATE JANITOR
CLOSET ENTRANCE� MATCH
EXISTING PASS-THROUGH
OPENING WIDTH�
REPLACE BLOCK WITH
CORNER BLOCKS TO CREATE
SMOOTH FINISHED OPENING
BLOCK UP EXISTING
�0'-0" X 4'-0"
PASS-THROUGH
OPENING�
D3 D4
INSTALL NEW �6" DOOR
NOTE:
FIELD MEASURE EXISTING
OPENING TO DETERMINE
IF CUSTOM DOOR SI;ING
IS RE2UIRED�
EXISTING CMU BLOCK
60'-0"
NEW BUILDING
E A
40'-0" o (FIELD VERIFY)
EXISTING BUILDING
D
�'-4"
A�0�
A�0�
A�0�26 GA� ROOF LINER
SHEETING
L1
FULL HEIGHT SPLIT
FACE MASONRY
BLOCK WALL
26 GA� WALL
LINER SHEETING
26 GA� WALL
SHEETING
24 GA� SEAM-LOK
STANDING SEAM ROOF
END WALL
COLUMN
A
A�0�
26 GA� WALL LINER
SHEETING
4' -0
EXISTING
BUILDING
OUTLINE
(BEYOND)
OFFICEKITCHENMECHANICAL ROOMHALLWAYBATHROOM
EXISTING WOOD FRAMED
DRYWALL CEILING
EXISTING WOOD TRUSSES
EXISTING CMU BLOCK
PARTITION WALLS
EXISTING CMU
BLOCK WALLS
A��0
�2 '-0
" o (F
IE
LD
V E
R
IF
Y
E A
V E
H E
IG
H
T
40'-0" o (FIELD VERIFY)
EXISTING BUILDING
REMOVE ASPHALT SHINGLES
FROM EXISTING ROOF AND
INSTALL NEW 24 GA� SEAM-LOK
STANDING SEAM ROOF TO
MATCH NEW BUILDING ADDITION
A��0
CONSTRUCT NEW �'-0"
OVERHANG WITH
SOFFIT ON ALL �
SIDES OF EXISTING
BUILDING
REMOVE EXISTING BATT
INSULATION AND INSTALL NEW R��
FIBERGLASS INSULATION IN ATTIC
LOW PROFILE
RIDGE VENT
NEW 26 GA� "R" PANEL
SHEETING TO MATCH
NEW BUILDING ADDITION
4"
SCALE:
0329-001
JOB:
DWG:
A.06
B U
IL
D
IN
G
S E
C T
IO
N
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
SECTION THRU EXISTING BUILDINGB
A�06 SCALE: ���" � �'-0"
SECTION THRU NEW BUILDINGA
A�06 SCALE: ��4" � �'-0"
BKK
BKK
JRE
EAH
/1 2/
R
E V
IS
E
D A
S S
H O
W
SCALE:
0329-001
JOB:
DWG:
A.07
D O
O R
, W
IN
D O
W A
N D
R O
O M
F
IN
IS
H
S C
H E
D U
L E
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
NOTES
DOOR SWING DIAGRAMS
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
A B C D
H
W
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
AI BI CI DI
NOTE: BOTH LEAVES ACTIVE � SWINGE
DOOR TYPES
H
W
� �'-0" Y �'-0" HEAVY DUTY
TO BE
SELECTED BY
OWNER
YES
DIAMOND MAR2UIS PRE-ASSEMBLED EXTERIOR DOORS:
�� GAUGE GALVANI;ED (A40) SMOOTH DOOR
�4 GAUGE GALVANI;ED (A40) KERF
FRAME
GRADE 2 LEVER LOCK
INTERCHANGEABLE BARREL WITHOUT LOCKSET
PANIC
DEVICE
CLOSER
�6 GAUGE GALVANI;ED (A40) �Ä SUBFRAME SYSTEM
BALL BEARING
NRP ÃSILVERÄ POWDER COAT HINGES
�-��4Ä ALUMINUM THRESHOLD
FULL PERIMETER
KERF WEATHERSEAL
AND EXTERIOR MOUNTED SWEEP�DRIP�
AD1
W1 4
MARK QTY.
WINDOW SCHEDULE
�'-0" X �'-0"
ALUMINUM
THERMAL
BREAK
REMARKS
NOMINAL SIZE
(W x H) GLASS FRAME
A
TYPE
H
W
DIAMOND PRE-ASSEMBLED WINDOW WITH �" SUBFRAME SYSTEM
UNIVERSAL FIN (TRIM)CLEAR
INSULATED
MARK QTY.
MAN DOOR SCHEDULE
SIZE SWING PANIC CLOSER
KEYLESS
ENTRY
COLORMATERIAL
NOTES
CHI MODEL �2�� MICRO-GROOVE INSULATED SECTIONAL DOORS WITH RIGHT SIDE
MOUNTED LIFTMASTER MAXUM MODEL JDC�S�BMC
��2 HP E2UIVALENT
�20 VOLT
JACKSHAFT OPERATOR� DOOR TRACK TO FOLLOW THE ROOF PITCH� IN ADDITION TO
THE INDIVIDUAL DOOR CONTROLS
PROVIDE ONE MUSHROOM-BUTTON CONTROL
STATION TO ACTIVATE ALL GARAGE DOORS AT ONCE - LIFTMASTER PART � 02-40�M�
COORDINATE LOCATION WITH FIRE DEPARTMENT�
MARK QTY.
OVERHEAD DOOR SCHEDULE
OPERATOR
MANUAL ELECTRIC
COLORGAUGESIZE WINDOWSWINDLOCKS
4 �4'-0" Y �4'-0"
YES
(�RD PANEL) 26NOGD1 X
TO BE
SELECTED BY
OWNER
HOLLOW
METAL
INSULATED
� FIELD
VERIFY STANDARDNOAD3
HOLLOW
METAL
INSULATED
COLOR
� �'-0" Y �'-0" HEAVY DUTYYESBD2
HOLLOW
METAL
INSULATED
� FIELD
VERIFY STANDARDNOBD4
HOLLOW
METAL
INSULATED
DIAMOND MAR2UIS PRE-ASSEMBLED INTERIOR DOORS:
20 GAUGE GALVANI;ED (A40) SMOOTH DOOR
�6 GAUGE GALVANI;ED (A40) KERF
FRAME
GRADE 2 LEVER LOCK
CLOSER
BALL BEARING NRP ÃSILVERÄ POWDER
COAT HINGES
�-��4Ä ALUMINUM THRESHOLD
FULL PERIMETER KERF
WEATHERSEAL
INTERIOR DOOR
WITH 6"X�0 LITE
TYPE B
A
TYPE
B
A
B
BKK
BKK
JRE
EAH
2'-� ���6" X 2'-� ���6"
FRAMED
OPENING SIZE
(W x H)
NOTES:
�� THRESHOLDS AT DOORS SHALL BE NO MORE THAN ��2" (MAX�)
HEIGHT A�F�F�
2� ALL DOOR HANDLES
PULLS
LATCHES
LOCKS AND OTHER
OPERATING DEVICES SHALL BE INSTALLED �4" (MIN�) TO 4�" (MAX�)
A�F�F� AND SHALL BE SINGLE HAND OPERABLE WITHOUT USE OF KEY
OR SPECIAL KNOWLEDGE�
�� CONTROLS AND OPERATING MECHANISMS SHALL BE LEVER TYPE
(OR E2UAL) AND NOT RE2UIRE TIGHT GRASPING
PINCHING
OR
TWISTING OF THE WRIST�
4� THE FORCE RE2UIRED TO ACTIVATE CONTROLS OF INTERIOR
HINGED DOORS SHALL BE NO GREATER THAN � POUNDS�
�� ALL DOOR HARDWARE TO MEET ADA RE2UIREMENTS�
6� DOORS E2UIPPED WITH CLOSERS SHALL BE ADJUSTED TO ADHERE
TO ADA GUIDELINES�
�� ALL INTERIOR AND EXTERIOR DOORS AND DOOR FRAMES TO BE
PAINTED� SHERWIN WILLIAMS
DIRECT TO METAL
SEMI-GLOSS
COLOR SELECTED BY OWNER�
�� ALL DOORS FURNISHED WITH BUILDING SUPPLY�
CONCRETE
FLOOR
ROOM / AREA
GARAGE
ROOM FINISH SCHEDULE
NEW JANITOR CLOSET
WALLS CEILING
MATERIAL BASE NORTH EAST SOUTH WEST MATERIAL HEIGHT
EXISTING
DRYWALL� PAINT �'-6"
ROOF LINER
PANEL
VARIES:
FOLLOWS 4:�2
ROOF PITCH
NOTES:
�� NEW JANITOR CLOSET WALLS- ���" MOISTURE RESISTANT DRYWALL (GREENBOARD)
2� WALL PAINT
SHERWIN WILLIAMS
PROMAR 200
EGGSHELL- ONE (�) COAT PRIMER
TWO (2) COAT FINISH
COLORS SELECTED BY OWNER�
�� CEILING PAINT
SHERWIN WILLIAMS
PROMAR CEILING
FLAT- ONE (�) COAT PRIMER
TWO (2) COAT FINISH
COLORS SELECTED BY OWNER�
4� VERIFY ALL MATERIAL AND COLOR SELECTIONS WITH OWNER�
�� GARAGE LINER PANELS FURNISHED WITH BUILDING SUPPLY AND INSTALLED BY BUILDING ERECTOR�
REMARKS
REMOVE EXISTING COVE BASE FROM CMU
WALL AND INSTALL NEW� DRYWALL
PAINT AND
INSTALL COVE BASE ON BOTH SIDES OF EAST
AND SOUTH WALL�
EXISTING CMU�
PAINT
COVE BASE TO
MATCH
EXISTING
CONCRETE
DRYWALL�
PAINT
DRYWALL�
PAINT AND 4'-0"
HIGH FRP WALL
PANEL
EXISTING CMU�
PAINT
4'-0" HIGH
SPLIT-FACE CMU
FULL HEIGHT
SPLIT-FACE CMUN�A FULL HEIGHT
LINER PANEL
ABOVE 4'-0"
FULL HEIGHT
LINER PANEL
ABOVE 4'-0"
FULL HEIGHT
LINER PANEL
ABOVE 4'-0"
EXISTING CMU�
PAINT
RIGID FRAME COLUMNS AND RAFTERS TO BE SHIPPED AND ERECTED WITH MANUFACTURERS SHOP PRIMER GRAY�
AFTER ERECTION IS COMPLETE
TOUCH UP ANY AREAS WHERE THE FACTORY APPLIED SHOP PRIMER HAS BEEN
DAMAGED�
26 GA� "R" PANEL
MATERIALITEM
PRE-ENGINEERED METAL BUILDING COMPONENT FINISH SCHEDULE
WALL SHEETING
COLOR/FINISH
BUCKSKIN TAN
24 GA� SEAM-LOK STANDING SEAMROOF SHEETING PARCHMENT
26 GA� "R" PANELROOF LINER SHEETING WHITE
26 GA� "R" PANELWALL LINER SHEETING WHITE
26 GA� "R" PANELSOFFIT SHEETING BUCKSKIN TAN
AS PER BUILDING MANUFACTURERBASE TRIM BRIGHT RED
AS PER BUILDING MANUFACTURERCORNER TRIM BRIGHT RED
DOOR AND WINDOW TRIM BRIGHT RED
EAVE TRIM BRIGHT RED
RAKE TRIM
GUTTERS
DOWNSPOUTS
AS PER BUILDING MANUFACTURERWALL GIRTS AND PURLINS PREGALVANI;ED
AS PER BUILDING MANUFACTURERRIGID FRAME COLUMNS AND RAFTERS SHOP PRIMERED GRAY*
AS PER BUILDING MANUFACTURER
AS PER BUILDING MANUFACTURER
AS PER BUILDING MANUFACTURER
AS PER BUILDING MANUFACTURER
AS PER BUILDING MANUFACTURER
BRIGHT RED
BRIGHT RED
BUCKSKIN TAN
4'-0" HIGH
SPLIT-FACE CMU
4'-0" HIGH
SPLIT-FACE CMU
OWNER TO SELECT SPLIT-FACE CMU COLOR
TO BE
SELECTED BY
OWNER
TO BE
SELECTED BY
OWNER
TO BE
SELECTED BY
OWNER
TO BE
SELECTED BY
OWNER
H
W
EXTERIOR DOOR
WITH �0"X�0 LITE
TYPE A
FIXED WINDOW
TYPE A
H
W
DOUBLE HUNG
WINDOW
TYPE B
W2 2 �'-0" X 2'-�"
VINYL
FRAME TO
MATCH
EXISTING
A PREP MASONRY OPENING FOR NEW REPLACEMENT WINDOW� FLASH AND SEAL PER
MANUFACTURER RECOMMENDATIONS�
FROSTED
INSULATED
�'-0" X 2'-�"
(FIELD VERIFY CMU
OPENING SI;E)
TO BE
SELECTED BY
OWNER
AS PER BUILDING MANUFACTURERRIDGE CAP�VENT PARCHMENT
26 GA� PREFINISHED COLOR STRIPSNOW RETENTION SYSTEM PARCHMENT
/1 2/
R
E V
IS
E
D A
S S
H O
W N
X
� �'-0" Y �'-0" HEAVY DUTY
TO BE
SELECTED BY
OWNER
YES
DIAMOND MAR2UIS PRE-ASSEMBLED EXTERIOR DOORS:
�� GAUGE GALVANI;ED (A40) SMOOTH DOOR
�4 GAUGE GALVANI;ED (A40) KERF
FRAME
GRADE 2 LEVER LOCK
INTERCHANGEABLE BARREL WITHOUT LOCKSET
PANIC
DEVICE
CLOSER
�6 GAUGE GALVANI;ED (A40) MASONRY INSTALLATION
BALL
BEARING NRP ÃSILVERÄ POWDER COAT HINGES
�-��4Ä ALUMINUM THRESHOLD
FULL
PERIMETER KERF WEATHERSEAL
AND EXTERIOR MOUNTED SWEEP�DRIP�
AD5
HOLLOW
METAL
INSULATED
B
DOOR JAMB�FRAME
CAULK
SUBFRAME JAMB
EXTERIOR TRIM
INSULATED METAL
DOOR
EXTERIOR WALL
PANEL
CAULK
INSULATED METAL
DOOR
THRESHOLD: CAULK AND
ANCHOR TO FLOOR WITH
PROVIDED ANCHORS
HEADER
JAMB
SILL
FLOOR LEVEL
INSULATED METAL
DOOR
CAULK
DOOR HEADER�FRAME
CAULK
INTERIOR WALL PANEL
INTERIOR TRIM
INTERIOR TRIM
INTERIOR WALL PANEL
EXTERIOR TRIM
SUBFRAME HEADER
EXTERIOR WALL
PANEL
PORTAL FRAME
RAFTER IN BRACED
BAY ONLY
SILL
FLOOR LEVEL
JAMB
HEADER
�4 '-0
DOOR CLOSURE STRIP
HEADER
DOOR HEADER�LINTEL
SOFFIT
DOOR CLOSURE STRIP
DOOR CLOSURE STRIP
SPLIT FACE CMU BLOCK
DOOR TRACK
SECTIONAL DOOR
SECTIONAL DOOR
DOOR TRACK
ANCHOR DOOR TRACK PER DOOR
MANUFACTURERS SPECIFICATIONS
DOOR TRACK
SUPPORT
BRACING
ALL SPLIT FACE BLOCK AT
DOOR OPENINGS TO
HAVE SMOOTH FACE�
SPLIT FACE CMU BLOCK
DOOR TRACK
SECTIONAL DOOR
ROOF
LINER
SHEETING
TRIM
24 GA� SEAM-LOK
STANDING SEAM ROOF
�6
H E
A D
R O
O
M INCLINED
DOOR TRACK
RIGID FRAME
(BEYOND)
ANGLE CLIP IN
ACCORDANCE WITH
MANUFACTURER'S
RECOMMENDATIONS (TYP�)
LOUVER
LOUVER WITH OPERABLE
DRAINABLE BLADES
CAULK
ANGLE CLIP IN
ACCORDANCE WITH
MANUFACTURER'S
RECOMMENDATIONS (TYP�)
HEADER
JAMB
SILL
INTERIOR TRIM
EXTERIOR TRIM
SILL CHANNEL SHIM LOUVER AS RE2UIRED
ANGLE CLIP IN ACCORDANCE
WITH MANUFACTURER'S
RECOMMENDATIONS (TYP�)
EXTERIOR TRIM
EXTERIOR WALL
PANEL
GIRT CLIP AS
RE2UIRED (TYP�)
INTERIOR WALL PANEL
INTERIOR TRIM
CAULK
LOUVER WITH OPERABLE
DRAINABLE BLADES
CAULK
HEADER CHANNEL
EXTERIOR WALL
PANEL
INTERIOR TRIM
INTERIOR WALL PANEL
EXTERIOR TRIM
JAMB CHANNEL
CONTINUOUS SEALANT AT
PERIMETER
BOTH SIDES� USE
BACKER ROD IF RE2UIRED�
HEADER CHANNEL
EXTERIOR WALL PANEL
INTERIOR TRIM
INTERIOR WALL PANEL
EXTERIOR TRIM
SHIM AS RE2UIRED
EXTERIOR WALL PANEL
INTERIOR TRIM
EXTERIOR TRIM
INTERIOR WALL PANEL
SILL CHANNEL
GRAVITY
BACKDRAFT
DAMPER
EXHAUST
FAN
F1 �'
FR
A
M E
D O
P E
N
IN
G
WALL MOUNTING CURB
FIXED-GLASS WINDOW
HEADER
JAMB
SILL
INTERIOR TRIM
SUBFRAME SILL
UNIVERSAL FIN
WINDOW TRIM
EXTERIOR WALL
PANEL INTERIOR WALL PANEL
INTERIOR TRIM
EXTERIOR WALL
PANEL
INTERIOR TRIM
INTERIOR WALL PANEL
SUBFRAME JAMB
FIXED-GLASS WINDOW
UNIVERSAL FIN
WINDOW TRIM
INTERIOR WALL PANEL
UNIVERSAL FIN
WINDOW TRIM
FIXED-GLASS WINDOW
SUBFRAME HEADER
RUBBER BASE COVE
(BOTH SIDES)
���" MOISTURE RESISTANT
DRYWALL (BOTH SIDES)�
FASTEN TO METAL STUDS WITH
� ��4" TYPE 'S'
FINE-THREAD
DRYWALL SCREWS - �" O�C
EDGES
�2" O�C FIELD�
STAGGER JOINTS (TYP�)
�6" O�C MAX�
20 GA� (VERIFY)
METAL BASE
TRACK� FASTEN TO
CONCRETE W� MECH�
ANCHORS 2'-0" O�C MAX�
20 GA� METAL TOP TRACK
20 GA� METAL STUD (TYP�)
(�6 GA� ! BEARING WALLS)
SPACING� ALIGNMENT BAR
PER MFR� SPECIFICATIONS�
CLARK DIETRICH OR E2UAL�
JANITOR CLOSET (EAST AND SOUTH WALL) FRAMING DETAIL
NOT TO SCALE
A�0�
FASTEN BLOCKING
AT EACH STUD�
20 GA� TRACK PIECE W�
� ��4" (MIN�) FLANGES
NOTCHED AS RE2UIRED�
MIN� 6" WIDE�
CLARK DIETRICH OR E2UAL�
NOTE:
PROVIDE AT ALL LOCATIONS
WHERE E2UIPMENT OR FIXTURES
WILL MOUNT TO THE WALL
TYPICAL STUD
E2 �
TYPICAL BLOCKING DETAIL
NOT TO SCALE
E2 �
E2 �
E2 �
A�0�
SCALE:
0329-001
JOB:
DWG:
A.08
D E
T A
IL
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
MAN DOOR DETAIL�
A�0� NOT TO SCALE
LOUVER DETAIL�
A�0� NOT TO SCALE
OVERHEAD DOOR DETAIL4
A�0� NOT TO SCALE
EXHAUST FAN DETAIL�
A�0� NOT TO SCALE
WINDOW DETAIL6
A�0� NOT TO SCALE
BKK
BKK
JRE
EAH
24 GAUGE SEAM-LOK STANDING
SEAM ROOF SHEETING
6 MIL POLY VAPOR BARRIER
PURLIN
26 GAUGE
INTERIOR ROOF
SHEETING
TRIM
6" UNFACED R�� INSULATION
BETWEEN PURLINS
GUTTER
EAVE STRUT
26 GAUGE SOFFIT
SHEETING
SPLIT FACE
MASONRY BLOCK
���" UNFACED R�� INSULATION
OVER PURLINS
SOFFIT
SUPPORT ANGLE
EAVE
COVER TRIM
SOFFIT
COVER TRIM
"J" TRIM
4'-0"
S-� COLORGARD SNOW
RETENTION SYSTEM
STEEL
LINE
24 GAUGE STANDING
SEAM ROOF SHEETING
���" UNFACED R��
INSULATION OVER PURLINS
PURLIN
26 GAUGE
INTERIOR ROOF
SHEETINGTRIM
6" UNFACED R��INSULATION
BETWEEN PURLINS
GUTTER
EAVE STRUT
26 GAUGE SOFFIT SHEETING
26 GAUGE EXTERIOR
WALL SHEETING
26 GAUGE
INTERIOR WALL
SHEETING
� ��2" UNFACED R�0
INSULATION (COMPRESSED)
BETWEEN THE GIRTS
6 MIL POLY VAPOR BARRIER
6 MIL POLY
VAPOR BARRIER
"J" TRIM
EAVE COVER TRIM
SOFFIT COVER TRIM �'-0"
S-� COLORGARD SNOW
RETENTION SYSTEM
26 GAUGE EXTERIOR
WALL SHEETING
WALL GIRT
6 MIL VAPOR
BARRIER
STEEL
LINE
� ��2" UNFACED R�0
INSULATION
(COMPRESSED)
BETWEEN THE GIRTS
26 GAUGE
INTERIOR WALL
SHEETING
� ��2"
BASE
TRIM
4' -0
S
P
LI
TF
A
C E
B
LO
C K
BASE CHANNEL
ANCHORED TO
STEM WALL WITH
MASONRY ANCHORS
AT �'-0" ON CENTER
MAX� SPACING
J-TRIM
SILL SEAL GASKET
RAKE TRIM
RAKE SUPPORT ANGLE
SOFFIT COVER TRIM
26 GA� SOFFIT
SHEETING
24 GAUGE STANDING
SEAM ROOF SHEETING
STANDING
SEAM ROOF
CLIPS
"J" TRIM
26 GAUGE EXTERIOR WALL SHEETING
FLASHING TRIM
EXISTIG WOOD
TRUSSES
EXISTING COMMON
BLOCK WALL
���" UNFACED
R�� INSULATION
OVER PURLINS
26 GAUGE INTERIOR
ROOF SHEETING
6" UNFACED R��
INSULATION
BETWEEN PURLINS
26 GAUGE INTERIOR
WALL SHEETING
� ��2" UNFACED R�0
INSULATION BETWEEN
THE GIRTS
6 MIL POLY VAPOR BARRIER RAKE SUPPORT ANGLE
CONTINUOUS SHEETING
ANGLE FASTENED TO ROOF
HAT CHANNEL <PURLINS>
STANDING SEAM
ROOF CLIPS
WALL GIRT
LINER TRIM
CUSTOM BENT
J-TRIM
SHEETING ANGLE
RAKE COVER (OPEN CEE)
RIGID FRAME
RAFTER
�'-0"
� ��2" DEEP X �6 GA�
HAT CHANNEL ! 4�" MAX�
SPACING�
FASTEN TO CMU WALL WITH
CONCRETE FASTENERS
TOP OF EXISTING
COMMON BLOCK WALL
SHEETING ANGLE
FASTENED TO WALL GIRTS
THERMAL SPACER
4' -0
" M A
X � S
P A
C
IN
G 4'
-0
A B
O V
E F
IN
IS
H E
D F
LO
O
R
FINISHED FLOOR
ATTIC INSULATION NOT
SHOWN FOR CLARITY
RAKE CLEAT
� ��2" DEEP X �6 GA� HAT
CHANNEL <PURLINS>
(�'-0" MAX SPACING)
SCALE:
0329-001
JOB:
DWG:
A.09
D E
T A
IL
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
TYP. INSULATED WALL/ROOF DETAIL AT 1'-0" OVERHANG�
A�0� SCALE: ��4" � �'-0"
TYP. INSULATED WALL DETAIL2
A�0� SCALE: ��4" � �'-0"
TYP. INSULATED WALL/ROOF DETAIL AT 4'-0" OVERHANG�
A�0� SCALE: ��4" � �'-0"
BKK
BKK
JRE
EAH
TYP. SECTION AT COMMON BLOCK WALLA
A�0� SCALE: � ��2" � �'-0"
/1 2/
R
E V
IS
E
D A
S S
H O
W
EXISTING CMU
BLOCK WALLS
CL
CL
CL
SISTE3 NEW �X� Y����� BOA3% TO
EXISTING �
T3USSES AN% ATTAC)
WIT) CONST3UCTION A%)ESI7E AN%
��% NAILS STAGGE3E% E7E3: ��
SISTE3 NEW �X� Y 'ULL LENGT)
BOA3% TO EXISTING �
T3USSES
AN% ATTAC) WIT) CONST3UCTION
A%)ESI7E AN% ��% NAILS
STAGGE3E% E7E3: ��
3EIN'O3CE T)E 'I3ST �
T3USSES ON T)E NO3T) SI%E
O' T)E EXISTING BUIL%ING
AS S)OWN 'O3 A%%ITIONAL
SNOW %3I'T LOA% SU11O3T
����� MINIMUM O7E3LA1
�X� T3USS EXTENSION�
SISTE3 NEW �X� NEXT TO EXISTING T3USSES AN% ATTAC) WIT)
CONST3UCTION A%)ESI7E AN% ��% NAILS STAGGE3E% E7E3: ��
TO C3EATE NEW ����� 3OO' O7E3)ANG� O7E3LA1 A MINIMUM O'
����� ONTO EXISTING T3USS�
EXISTING T3USS
�+� T3IM 'ASTENE% TO
WALL S)EETING WIT)
SC3EWS AT ��� ON CENTE3
NEW �����
O7E3)ANG
�X� 'ASCIA
BOA3%
GUTTE3
�� GA�
SO''IT
1ANEL
EXISTING CMU BLOCK�B3ICK WALL
� ���� %EE1 X �� GA� )AT
C)ANNELS <1U3LINS> ATTAC)E%
TO EXISTING 3OO' %ECK
����� MAX� S1ACING
NEW �� GA� SEAM�LOK STAN%ING
SEAM 3OO' TO MATC) NEW
BUIL%ING A%%ITION
3EMO7E EXISTING 'ASCIA BOA3%
EA7E CO7E3 T3IM
SO''IT CO7E3 T3IM
EA7E 1LATE
METAL CLOSU3E
GUTTE3 ST3A1
STAN%ING SEAM
3OO' CLI1S
CUT BACK EXISTING 3OO' %ECK S)EAT)ING TO ALLOW
ACCESS TO INSTALL NEW �X� T3USS EXTENSIONS�
3E1LACE WIT) NEW S)EAT)ING O' T)E SAME T)ICKNESS�
�� GAUGE EXTE3IO3
WALL S)EETING
� ���� %EE1 X �� GA� )AT C)ANNEL ! ��� MAX� S1ACING�
'ASTEN TO CMU WALL WIT) CONC3ETE 'ASTENE3S
S�� COLO3GA3% SNOW
3ETENTION S:STEM
MAX� S1ACING
� ���� %EE1 X �� GA� )AT
C)ANNEL <1U3LINS>
����� MAX S1ACING
NEW �� GA� SEAM�LOK
STAN%ING SEAM 3OO'
TO MATC) NEW
BUIL%ING A%%ITION
STAN%ING SEAM 3OO' CLI1S
LOW 13O'ILE SS3 3I%GE 7ENT
BACKU1
1LATE
OUTSI%E CLOSU3E
EXISTING
T3USS
EXISTING
3OO' %ECK
3AKE T3IM
3AKE SU11O3T
NEW S)EAT)ING
SO''IT CO7E3 T3IM�� GA�
SO''IT
1ANEL
NEW �����
O7E3)ANG
�X� BLOCKING
! ��� O�C�
� ���� %EE1 X �� GA� )AT
C)ANNELS <1U3LINS>
ATTAC)E% TO EXISTING
3OO' %ECK
����� MAX� S1ACING
3EMO7E EXISTING 3OO' %ECK
S)EAT)ING BACK TO �N% T3USS
EXISTING T3USSES
NEW �� GA� SEAM�LOK
STAN%ING SEAM 3OO' TO
MATC) NEW BUIL%ING A%%ITION
STAN%ING
SEAM 3OO'
CLI1S
C �N% T3USSL
�+� T3IM
NEW �X� LA%%E3 '3AME%
GABLE EXTENSION WIT) �X�
BLOCKING AT ��� O�C�
'ASTENE% TO EXISTING EN%
T3USS WIT) CONST3UCTION
A%)ESI7E AN% ��% NAILS
STAGGE3E% AT E7E3: ���
NEW �� GA� �3� 1ANEL GABLE S)EETING
� ���� %EE1 X �� GA� )AT
C)ANNEL ! ��� MAX� S1ACING�
TE3MINATION T3IM
T)E3MAL S1ACE3
EXISTING CMU
BLOCK�B3ICK WALL
�� GAUGE EXTE3IO3
WALL S)EETING
� ���� %EE1 X �� GA�
)AT C)ANNEL ! ���
MAX� S1ACING�
'ASTEN TO CMU WALL
WIT) CONC3ETE
'ASTENE3S
'INIS)E%
G3A%E
CUSTOM BENT
BASE T3IM
CUSTOM BENT
+�T3IM
EXISTING CMU
BLOCK�B3ICK WALL
�� GAUGE
EXTE3IO3
WALL S)EETING
� ���� %EE1 X �� GA� ;EE
'U33ING
'ASTENE% TO
CMU WALL A3OUN%
1E3IMETE3 O' EXISTING
%OO3�WIN%OW O1ENING�
EXISTING %OO3 O3
WIN%OW O1ENING
CUSTOM BENT
+AMB CO7E3 T3IM
SILICONE SEALANT
1O1 3I7ET
OUTSI%E
CO3NE3 T3IM
�� GAUGE EXTE3IO3
WALL S)EETING
EXISTING CMU
BLOCK�B3ICK WALL
A
T C
A
N N
E L
)AT C)ANNEL
INSI%E
CO3NE3 T3IM
�� GAUGE EXTE3IO3
WALL S)EETING
EXISTING CMU
BLOCK�B3ICK WALL
)AT C)ANNEL
N E
W B
U
IL
IN
G W
A
LL
G I3
T
SCALE:
0329-001
JOB:
DWG:
A.10
D E
T A
IL
S
3/11/24
DATE:
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
EXISTING TRUSS REINFORCING DETAILA
A��� SCALE� ���� � �����
BKK
BKK
JRE
EAH
TYP. PEAK DETAIL ON EXISTING BUILDING�
A��� SCALE� �� � �����
TYP. EAVE EXTENSION DETAIL OF EXISTING BUILDING�
A��� SCALE� � ���� � �����
TYP. LADDER FRAME GABLE EXTENSION OF EXISTING BUILDING�
A��� SCALE� � ���� � �����
TYP. BASE DETAIL OF EXISTING BUILDINGB
A��� SCALE� � ���� � �����
TYP. TRIM DETAIL AT EXISTING DOOR / WINDOW OPENINGE
A��� SCALE� � ���� � �����
TYP. OUTSIDE CORNER DETAIL OF EXISTING BUILDINGC
A��� SCALE� � ���� � �����
TYP. INSIDE CORNER DETAIL OF EXISTING BUILDING%
A��� SCALE� � ���� � �����
/1 2/
R
E V
IS
E
D A
S S
H O
W N
NOTE�
BE'O3E INSTALLATION O' METAL 'U33ING AN% WALL S)EETING
ALL 13OT3U%ING B3ICK
WIN%OW SILLS MUST BE SAW�CUT BACK TO BE 'LUS) WIT) T)E A%+ACENT CMU MASON3:
WALL� A'TE3 CUTTING
T)E CONT3ACTO3 MUST INS1ECT T)E 3EMAINING B3ICK 'O3 AN:
LOOSE UNITS O3 COM13OMISE% MO3TA3� AN: LOOSE MASON3: MUST BE 3E1OINTE% O3
STABILI;E% TO MAINTAIN T)E WALL�S ST3ENGT)�
SCALE:
0329-001
JOB:
DWG:
S.01
IM
P
E R
IA
L
V O
L . F
IR
E
D E
P T
C
O N
C R
E T
E N
O T
E S
3/11/24
DATE:
S U
B -S
T A
T
IO
N B
U
IL
D
IN
G E
X P
A N
S
IO
N
M A
T C
H E
T T
E R
D
C
LI
N T
O N
, P A
DGN:
DWN:
CHK:
APP:
AS SHOWN
R E
V
D A
T E
D E
S C
R
IP
T
IO
N
SEAL:
DRAWING STATUS:
BID
B
R O
A D
W A
Y S
T R
E E
T C
A R
N E
G
IE
P
A
.8
.5 w w w .r ed co ne ng in ee rin g.
co m
BKK
BKK
JRE
EAH
HIGH EARLY STRENGTH CONCRETE:
�� THIS SECTION APPLIES TO TYPE III PORTLAND CEMENT ONLY�
2� HIGH EARLY STRENGTH CONCRETE SHOULD ONLY BE USED WHEN APPROVED BY OWNERS ENGINEER�
�� CONTRACTOR SHALL SUBMIT MIX DESIGN TO OWNERS ENGINEER FOR APPROVAL� OWNERS ENGINEER MUST APPROVE TYPE
III CONCRETE USE BEFORE BATCHING� FOR HIGH EARLY STRENGTH CONCRETE
TEST BREAKS MUST INDICATE MINIMUM �0�
OF THE MINIMUM DESIGN STRENGTH BEFORE LOADS SHALL BE APPLIED� UNDER NO CIRCUMSTANCE SHALL THE MAXIMUM
LOADING EXCEED THE COMPRESSIVE STRENGTH OF THE CONCRETE�
4� CONTRACTOR SHALL PROVIDE CONCRETE BATCH TESTING REPORTS AND OBTAIN OWNERS ENGINEER APPROVAL OF MIX AND TEST CYLINDER BREAKS PRIOR TO USING HIGH EARLY STRENGTH CONCRETE� CONTRACTOR SHALL SUBMIT TEST BREAK
RESULTS AFTER � DAYS
�4 DAYS
AND 2� DAYS OF CURING
OR AT OTHER INTERVALS AS SPECIFIED BY OWNER�
�� HIGH EARLY STRENGTH CEMENT SHALL NOT BE USED WHEN THE AMBIENT TEMPERATURE IS ABOVE
OR IS FORECASTED TO
BE ABOVE
�0n F AT TIME OF PLACEMENT�
6� HIGH EARLY STRENGTH CEMENT SHALL NOT BE USED WHEN THE AMBIENT TEMPERATURE IS BELOW
OR IS FORECASTED TO
BE BELOW
40n F DURING TIME OF PLACEMENT�
�� DETAILS AND METHODS OF PLACING AND HANDLING CONCRETE SHALL BE IN ACCORDANCE WITH THE PROCEDURES IN ACI ���
AND THE RE2UIREMENTS OF THIS SPECIFICATION�
�� WRITTEN APPROVAL FROM OWNERS ENGINEER IS RE2UIRED BEFORE USING ACCELERATING ADMIXTURES OR ADDITIONAL
CEMENT�
�� UNLESS SPECIFICALLY APPROVED BY OWNERS ENGINEER
CALCIUM CHLORIDE SHALL BE AVOIDED� HOWEVER
IF
NECESSARY
CALCIUM CHLORIDE MAY BE USED PROVIDED THAT NO MORE THE 2� OF CALCIUM CHLORIDE BY WEIGHT OF
CEMENT IS USED�
�0� THE PROPORTIONS OF CEMENT
WATER
COARSE AGGREGATE
FINE AGGREGATE
AND ADMIXTURES FOR EACH MIX DESIGN
SHALL BE FORWARDED TO OWNER FOR APPROVAL PRIOR TO DELIVERY OF ANY CONCRETE�
��� MOIST CURING SHALL CONSIST OF KEEPING THE CONCRETE CONTINUOUSLY WET FOR A PERIOD OF NOT LESS THAN � DAYS
WHEN USING HIGH EARLY STRENGTH PORTLAND CEMENT�
�2� CONCRETE FOUNDATIONS AND STRUCTURES SHALL BE ALLOWED TO CURE A MINIMUM OF � DAYS FOR TYPE III CONCRETE BEFORE ANY EXTERNAL LOADS ARE APPLIED� EXTERNAL LOADS ARE LIMITED TO ONLY ESSENTIAL E2UIPMENT WEIGHT AT THE TIME� TEST BREAKS MUST MEET OR EXCEED THE MAXIMUM LOAD CAPACITY OF THE E2UIPMENT BEFORE LOADING THE FOUNDATION� LOADING FOUNDATIONS THAT HAVE CURED LESS THAN � DAYS MUST BE APPROVED BY OWNERS ENGINEER
PRIOR TO PLACEMENT� FURTHERMORE
OWNERS ENGINEER MUST REVIEW AND APPROVE BREAKS PRIOR TO LOADING�
��� CONTRACTOR SHALL SUBMIT CONCRETE TESTING SCHEDULE WITH THE MIX DESIGN TO OWNER�
CONDITIONS
THICKNESS OF SECTIONS
LESS THAN �2" �2"-�6" �6"-�2" OVER �2"
60nF
6�nF
�0nF
MIN� TEMPERATURE
OF FRESH CONCRETE
AS MIXED FOR
WEATHER INDICATED
ABOVE �0nF
0nF TO �0nF
BELOW 0nF
��nF
60nF
6�nF
�0nF
��nF
60nF
4�nF
�0nF
��nF
MINIMUM TEMPERATURE OF FRESH
CONCRETE AS PLACED AND MAINTAINED
MAX� ALLOWABLE GRADUAL DROP IN
TEMPERATURE IN THE FIRST 24 HOURS
AFTER END OF PROTECTION
��nF �0nF 4�nF 40nF
�0nF 40nF �0nF 20nF
SERVICE
CATEGORY
NO LOAD
NOT EXPOSED
NO LOAD
EXPOSED
PARTIAL LOAD
EXPOSED
FULL LOAD
TYPE I OR II
CEMENT
2 DAYS
� DAYS
6 DAYS
CHECK IN-PLACE STRENGTH
TYPE III CEMENT� OR
ACCELERATING ADMIXTURE� OR
�00 LB�YD ADDITIONAL CEMENT
� DAY
2 DAYS
4 DAYS
COLD WEATHER CONCRETE:
�� COLD WEATHER CONCRETE WORK SHALL CONFORM TO ALL RE2UIREMENTS OF ACI �06R-�0
STANDARD SPECIFICATION FOR
COLD WEATHER CONCRETING
PUBLISHED BY THE AMERICAN CONCRETE INSTITUTE
EXCEPT AS MODIFIED BY THE
RE2UIREMENTS OF THESE DRAWINGS�
2� COLD WEATHER IS DEFINED WHEN THE AIR TEMPERATURE HAS FALLEN TO
OR IS EXPECTED TO FALL BELOW 40 DEGREES F
DURING THE PROTECTION PERIOD� THE PROTECTION PERIOD IS DEFINED AS THE TIME RE2UIRED TO PREVENT CONCRETE
FROM BEING AFFECTED BY EXPOSURE TO COLD WEATHER�
�� REMOVE ALL SNOW
ICE AND FROST FROM THE SURFACES
INCLUDING REINFORCEMENT
AGAINST WHICH THE CONCRETE IS
TO BE PLACED� BEFORE BEGINNING CONCRETE PLACEMENT
THAW THE SUBGRADE TO A MINIMUM DEPTH OF 6"�
4� CONTRACTOR SHALL MAINTAIN THE SURFACE TEMPERATURE OF THE CONCRETE THROUGHOUT THE LENGTH OF THE
PROTECTION PERIOD BASED ON THE FOLLOWING CHART:
CONTRACTOR SHALL PROTECT THE FRESH CONCRETE FROM FREE;ING UNTIL THE CONCRETE REACHES A COMPRESSIVE
STRENGTH OF �00 PSI OR BY THE NUMBER OF DAYS BASED ON THE FOLLOWING CHART:
�� DURING PERIODS NOT DEFINED AS COLD WEATHER
BUT WHEN FREE;ING TEMPERATURES MAY OCCUR
CONTRACTOR SHALL
PROTECT CONCRETE SURFACES AGAINST FREE;ING FOR THE FIRST 24 HOURS AFTER PLACEMENT�
GENERAL NOTES:
�� CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE PROJECT SITE PRIOR TO STARTING WORK AND SHALL
NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES�
2� CONTRACTOR TO VERIFY LAYOUT AND STARTING POINT OF BUILDING WITH REDCON ENGINEERING BEFORE STARTING WORK�
�� CONTRACTOR TO VERIFY TOP OF PIER ELEVATIONS IN RELATION TO FINISHED GRADE� FINISHED GRADE VARIES� REFER TO
SITE GRADING DRAWINGS BY OTHERS FOR FINISHED GRADE ELEVATIONS�
4� CONTRACTOR SHALL VERIFY THAT THE ANCHOR BOLT PLAN FROM THE BUILDING SUPPLIER MATCHES THE DIMENSIONS FOUND IN THE DRAWINGS� IF THE ANCHOR BOLT PLAN DIFFERS FROM THAT SHOWN ON THE DRAWINGS
CONTRACTOR SHALL
NOTIFY THE ENGINEER IMMEDIATELY�
�� UNLESS OTHERWISE NOTED
ALL ANCHOR BOLTS SHALL BE CAST IN PLACE�
REGULATORY REQUIREMENTS:
�� ALL CONCRETE WORK
UNLESS OTHERWISE SPECIFIED HEREIN OR CALLED FOR ON THE DRAWINGS
SHALL BE IN
ACCORDANCE WITH ALL OF THE PROVISIONS OF THE LATEST EDITION OF THE AMERICAN CONCRETE INSTITUTE (ACI)
BUILDING CODE:
A� ACI �0�: SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS�
B� ACI �0�R: RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING�
C� ACI �06R: RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING�
D� ACI ���: DETAILS AND DETAILING OF CONCRETE REINFORCEMENT�
E� ACI ���: BUILDING CODE RE2UIREMENTS FOR REINFORCED CONCRETE�
2� REINFORCING SHALL CONFORM TO AMERICAN SOCIETY FOR TESTING MATERIALS (ASTM) A6��
GRADE 60�
�� WELDED WIRE MESH OR FABRIC SHALL CONFORM TO ASTM A����
4� ANCHOR BOLTS SHALL CONFORM TO ASTM F���4
GRADE �6�
�� ALL CONCRETE SHALL BE MIXED AND DEPOSITED IN ACCORDANCE WITH THE RE2UIREMENTS SET FORTH IN "SPECIFICATIONS
FOR READY-MIXED CONCRETE" (ASTM C�4)�
CONCRETE AND FOUNDATION NOTES:
�� FOUNDATIONS ARE DESIGNED TO ALLOW FOR A SOIL BEARING CAPACITY OF 2
�00 PSF PER THE RECOMMENDATIONS IN THE
GEOTECHNICAL REPORT BY PENNSYLVANIA SOIL � ROCK
INC� DATED SEPTEMBER ��
202�� THE SOIL BENEATH THE SLAB ON
GRADE SHALL HAVE A MINIMUM MODULUS OF SUBGRADE REACTION (K) OF �2� PCI�
2� CONCRETE FOR PIERS
GRADE WALLS
AND FOOTERS SHALL HAVE A MINIMUM 2�-DAY COMPRESSIVE STRENGTH OF 4,000 PSI�
CONCRETE FOR FLOOR PADS SHALL BE 4,000 PSI. MAXIMUM ALLOWABLE SLUMP SHALL BE 4"�
�� CONTRACTOR SHALL PLACE THE CONCRETE IN ACCORDANCE WITH THE FOLLOWING:
A� THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE ON UNDISTURBED DECOMPOSED ROCK OR BEDROCK
PROPERLY
LEVELED AND CLEANED BEFORE PLACING CONCRETE�
B� ONCE THE BUILDING PAD AREA IS BROUGHT TO GRADE IT SHOULD BE THOROUGHLY COMPACTED WITH A LARGE VIBRATORY ROLLER� PROOF-ROLL THE COMPACTED SUBGRADE USING A FULLY LOADED TRI-AXLE AXLE DUMP TRUCK (WITH A MINIMUM 20 TON LOAD) TO IDENTIFY ANY SOFT AREAS� ANY SOFT AREAS THAT CAN NOT BE STABILI;ED IN-PLACE BY ADDITIONAL ROLLING SHOULD BE UNDERCUT AND REPLACED WITH SUITABLE FILL PRIOR TO SUBBASE PLACEMENT�
C� FLOOR SUBGRADE SHALL BE MOISTENED BY SPRINKLING BEFORE PLACING CONCRETE�
D� ALL CONCRETE SHALL BE PLACED IMMEDIATELY AFTER PROPER MIXING IN A MANNER SO AS TO PREVENT SEPARATION OF
INGREDIENTS� POWER VIBRATORS SHALL BE USED TO ASSURE A DENSE
SMOOTH JOB
FREE FROM VOIDS AND
HONEYCOMBS
BUT CARE MUST BE USED SO THAT THERE IS NO SEPARATION OF INGREDIENTS�
E� CONCRETE TEMPERATURE WHEN PLACED SHALL NOT EXCEED �0 DEGREES F�
F� FOG SPRAYING SHALL BE USED WHEN WIND AND TEMPERATURE CONDITIONS WOULD CAUSE RAPID SURFACE DRYING AND PLASTIC SHRINKAGE� SEE ACI �0�R FOR FURTHER RECOMMENDATIONS� CASTING OF WATER ON THE CONCRETE SURFACE
WILL BE STRICTLY PROHIBITED�
4� MINIMUM BAR LAPS SHALL BE NOT LESS THAN 40 DIAMETERS OR 24Ä
WHICHEVER IS GREATER (E�G�
�6 REBAR: 40 Y 0���" � �0")�
�� CONTRACTOR SHALL FINISH THE CONCRETE IN ACCORDANCE WITH THE FOLLOWING:
A� ALL FLOOR SLABS SHALL BE TRUE TO PLANE WITHIN ��4 INCHES IN �0 FEET AS DETERMINED BY A �0 FOOT LONG STRAIGHT EDGE PLACED ANYWHERE ON THE SLAB IN ANY DIRECTION� PITCH TO DRAIN AS SHOWN ON THE DRAWINGS�
B� ALL FLOOR SLABS SHALL BE MACHINE FLOATED AND THEN SHALL RECEIVE A STEEL TROWEL FINISH�
C� ANY HONEYCOMB OR OTHER DEFECTIVE AREAS SHALL BE CUT BACK TO SOLID CONCRETE WITH EDGES SLIGHTLY
UNDERCUT� THESE AREAS SHALL THEN BE PATCHED WITH ADHESIVE GROUT�
D� TOPS OF CONCRETE FOUNDATION PIERS SHALL BE FINISHED LEVEL AND TRUE WITH NO MORE THAN ��� INCHES
DIFFERENTIAL IN ANY DIRECTION�
E� CONCRETE CURING AND SEALING COMPOUND SHALL BE A HIGH SOLIDS
HIGH PERFORMANCE COMPOUND� "POLYSEAL-A"
BY CHEMMASTERS
INC�
OR APPROVED E2UAL�
6� ALL SUBGRADE FILL WITHIN THE PROPOSED BUILDING FOOTPRINT SHALL BE GRANULAR FILL MATERIAL PLACED IN
COMPACTION (MAXIMUM �2" LIFTS AT MINIMUM ��� COMPACTION)�
�� ALL EXTERIOR WALL BACKFILL SHALL BE APPROVED GENERAL FILL MATERIAL�
�� ALL EXTERIOR WALL AND PIER FOOTINGS SHALL BE PLACED ON UNDISTURBED SOIL� IN AREAS OF OVER-EXCAVATION �2"
GRANULAR BACKFILL SHALL BE PLACED AND COMPACTED TO A MINIMUM OF ����
HOT WEATHER CONCRETE
�� DETAILS AND METHODS OF PLACING AND HANDLING CONCRETE SHALL BE IN ACCORDANCE WITH THE PROCEDURES IN ACI
�0�R AND THE FURTHER RE2UIREMENTS OF THIS SPECIFICATION�
2� CONCRETE SHALL BE PROTECTED FROM HEAT AND DRYING BEFORE
DURING
AND AFTER PLACEMENT�
�� DURING MIXING
PLACING
AND CURING
CONCRETE TEMPERATURES SHALL BE MAINTAINED AT LESS THAN �0nF� TO REDUCE
THE CONCRETE TEMPERATURE
ICE MAY BE USED IN THE MIXING WATER IN 2UANTITIES UP TO �0� OF THE SPECIFIED WATER
PROVIDED THAT ALL OF THE ICE IS MELTED WHEN MIXING IS COMPLETE�
4� CARE SHALL BE TAKEN DURING BATCHING TO PREVENT FORMATION OF CEMENT BALLS�
�� AGGREGATE MAY BE COOLED BY SHADING
SPRAYING
OR BY OTHER OWNER-APPROVED METHODS� SPRAY WATER WILL
ALTER THE WATER-CEMENT RATIO
AND THUS MUST BE ACCOUNTED FOR IN THE WATER USED IN THE MIX DESIGN� THE
SPECIFIED WATER-CEMENT RATIO SHALL NOT BE EXCEEDED WITHOUT PRIOR APPROVAL FROM OWNER�
6� TO COUNTERACT THE ACCELERATING EFFECT OF HIGH TEMPERATURE AND TO LESSEN THE NEED FOR AN INCREASE IN
MIXING WATER
A RETARDER MAY BE USED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS
SUBJECT TO
ITS SUCCESSFUL PERFORMANCE IN A TRIAL MIX AND WRITTEN OWNER APPROVAL� USE OF RETARDERS OR OTHER
ADMIXTURES MUST BE INCLUDED IN THE MIX DESIGN (SECTION 4)�
�� HIGH EARLY STRENGTH CEMENT SHALL NOT BE USED WHEN THE AMBIENT TEMPERATURE IS ABOVE
OR IS FORECASTED TO
BE ABOVE
�0nF DURING TIME OF PLACEMENT�
�'-2"
�'-4"
2�'-�"
�4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0"
OVERHEAD DOOR
2'-4" 2'-4" �4'-0"
OVERHEAD DOOR
�'-4"
2'-0"
��'-�" ��'-�" 2�'-�"
'-0
'-0
N
E W
B U
IL
D
IN
G
'-0
'-0
�'-2"
2�'-�" ��'-�" ��'-�" 2�'-�"
2'-0"
� 2 � 4 �
A
B
C
E
2 � 4
E
FACE OF EXISTING
CMU BLOCK WALL
'-0
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .