2-Bid26044 Plans.pdf
PDF 1 MB Posted
- Solicitation number
- BID 26044
- Issued by
- Ada County, Idaho
About this file
Ada County Civic Plaza Store Front Replacement Project 2026
This file contains architectural construction documents for the Ada County Civic Plaza Store Front Replacement Project 2026, prepared by Lombard-Conrad Architects for Ada County, Idaho. The project involves the removal and replacement of multiple storefront windows and doors located on the first floor of the Ada County Civic Plaza Complex at 252 E. Front Street, Boise, Idaho. The work includes demolition of existing aluminum storefront framing, glazing systems, and entrance doors; removal and storage of existing awnings for later reinstallation; coordination with electrical systems; and installation of new aluminum storefront framing with insulated and tempered glazing units, automated sliding entrances, and associated hardware. The construction documents are dated April 10, 2026, and include detailed floor plans, demolition plans, door and window schedules, hardware specifications, and installation details across multiple sheets (A2.00 through A3.10).
The construction documents specify aluminum storefront Type 1 framing with 4½-inch depth, insulated glazing units with tinted exterior and clear interior tempered panes, and spandrel glass where applicable. Door hardware requirements include Best 9K Series locksets, Ives hinges, Von Duprin exit devices, LCN closers, and magnetic locks with access control coordination. The project requires field verification of all dimensions prior to fabrication, protection of existing conditions that are to remain, patching and repair of any damage caused by construction, and compliance with the 2018 International Building Code. All work must conform to applicable state and local codes and regulations. The contractor is responsible for properly disposing of all demolished materials in accordance with all applicable laws and regulations, with all dumping fees paid by the contractor.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-Bid26044 Bidders Bid Form.pdf | ||
| 1-Bid26044 Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GRAPHIC AND MATERIAL SYMBOLS
(NUMBERS AND LETTERS)
GRID LINE
1i
X
ROOM NAME
A101
SIM
SHEET NUMBER
DETAIL IDENTIFICATION
DETAIL
SHEET NUMBER
WALL SECTION
SECTION IDENTIFICATION
SHEET NUMBER
BUILDING SECTION
SECTION IDENTIFICATION
ROOM NUMBER
ROOM IDENTIFICATION
ROOM NAME
(NUMBER)
KEYNOTE
(NUMBER)
REVISION
DOOR LETTER
DOOR IDENTIFICATION
ROOM REFERENCE
A
WINDOW TYPE
(LETTER OR NUMBER)
WINDOW IDENTIFICATION
NORTH ARROW
CONTROL POINT OR
WORK POINT
DATUM POINT
TYPE NUMBER
WALL TAG
MATCHLINE
EARTH FILL
GRAVEL FILL
CONCRETE
SAND OR GROUT
BRICK OR STONE
CMU
STEEL
FINISH WOOD MEMBER
WOOD FRAMING MEMBER
WOOD BLOCKING
BATT BLANKET / BLOWN-IN
INSULATION / SPRAY APPLIED
FOAM INSULATION
RIGID INSULATION
PLYWOOD
GYPSUM BOARD
GLASS
CERAMIC TILE (PROFILE ONLY)
ACOUSTICAL TILE
SHEET NUMBER
ELEVATIONS
ELEVATION IDENTIFICATION
A101 2
A101
A101
N
VICINITY MAP
BOISE, IDAHO
N
PROJECT SITE
STATE OF IDAHO
LICENSED
ARCHITECT
AR-985148
MARK W. HEAZLE
651 2 3
651 2 3
B
C
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
A
D
E
CONSULTANTS:
PHASE:
COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, INC.
is unlawful and subject to criminal prosecution.
STAMP:
4/10/2026
/1
/2
:2 :0
A
M C
U s e rs
\b e n b \D o c u m e n ts \2
.0
A d a C o u n ty
S to re fr o n t R e p la c e m e n t_ C
E N
T R
A L
R b e n b lc a rc h .c o m
.r v t
0.00
26300.01
LC TEAM
LC TEAM
ADA COUNTY -
ADA COUNTY
PROJECT #26044
COVER SHEET
4/10/2026
ADA COUNTY
CIVIC PLAZA
STORE FRONT
REPLACEMENT
PROJECT 2026
CONSTRUCTION
DOCUMENTS
A.B. ANCHOR BOLT
ACOUS. ACOUSTICAL
ADJ. ADJUSTABLE
A.F.F. ABOVE FINISH FLOOR
AGGR. AGGREGATE
AL. ALUMINUM
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BOT. BOTTOM
CAB. CABINET
C.F.O.I. CONTRACTOR-
FURNISHED/OWNER-
INSTALLED
C.L. CENTERLINE
CLG. CEILING
CLR. CLEAR
C.M.U. CONCRETE
MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
CORR. CORRIDOR
CTSK. COUNTERSUNK
CNTR. COUNTER
CTR. CENTER
DBL. DOUBLE
DEPT. DEPARTMENT
D.F. DRINKING FOUNTAIN
DET. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DN. DOWN
EA. EACH
E.I.F.S. EXTERIOR
INSULATION
AND FINISH SYSTEM
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
ELEV. ELEVATION
ELEV. ELEVATOR
ENCL. ENCLOSURE
EQ. EQUAL
EQUIP. EQUIPMENT
EXP. EXPANSION
EXST. EXISTING
EXT. EXTERIOR
F.A. FIRE ALARM
F.D. FLOOR DRAIN
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
FF FACTORY FINISH
F.H.C. FIRE HOSE CABINET
FIN. FINISH
FLR. FLOOR
F.O.B. FACE OF BUILDING
F.O.C. FACE OF CONCRETE
F.O.E. FACE OF EXISTING
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUDS
FT. FEET/FOOT
FTG. FOOTING
FURR. FURRING
GA. GAUGE
GALV. GALVANIZED
GND. GROUND
GR. GRADE
GYP. GYPSUM BOARD
H.C. HOLLOW CORE
HDWD. HARDWOOD
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HGT. HEIGHT
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
JAN. JANITOR
JT. JOINT
KIT. KITCHEN
LAB. LABORATORY
LAV. LAVATORY
MAX. MAXIMUM
MECH. MECHANICAL
MTL. METAL
MFR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MTD. MOUNTED
N/C NON-COMBUSTIBLE
N.I.C. NOT IN CONTRACT
NO. NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O.A. OVERALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F.C.I. OWNER FURNISHED/
CONTRACTOR-
INSTALLED
O.F.O.I. OWNER FURNISHED/
OWNER INSTALLED
OFF. OFFICE
OPNG. OPENING
OPP. OPPOSITE
PL. PLATE
PL PLASTIC LAMINATE
PLAS. PLASTER
PLYWD. PLYWOOD
PR. PAIR
PT. POINT
P.T.D. PAPER TOWEL
DISPENSER
P.T.R. PAPER TOWEL
RECEPTACLE
Q.T. QUARRY TILE
RAD. RADIUS
R.D. ROOF DRAIN
REF. REFERENCE
REFR. REFRIGERATOR
REINF. REINFORCED
REQ. REQUIRED
RESIL. RESILIENT
RM. ROOM
R.O. ROUGH OPENING
R.W.L. RAIN WATER
LEADER
S.C. SOLID CORE
SECT. SECTION
SHTH'G. SHEATHING
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STA. STATION
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRL. STRUCTURAL
SUSP. SUSPENDED
T.C. TOP OF CURB
TEL. TELEPHONE
T.O. TOP OF
T.O.B. TOP OF BLOCK
T.O.C. TOP OF CURB
T.O.P. TOP OF PLATE
T.O.W. TOP OF WALL
TRD. TREAD
T.V. TELEVISION
TYP. TYPICAL
U.O.N. UNLESS
OTHERWISE NOTED
UR. URINAL
VERT. VERTICAL
VEST. VESTIBULE
W/ WITH
W/O WITHOUT
W.C. WATER CLOSET
WD. WOOD
W.P. WATERPROOF
W.R. WATER RESISTANT
WT. WEIGHT
A-E F-M N-R S-Z
SHEET INDEX
ADA COUNTY CIVIC PLAZA STORE
FRONT REPLACEMENT PROJECT
252 E. FRONT STREET, BOISE, ID 83702
APRIL 14, 2026
ABBREVIATIONS
FOR ADDITIONAL MATERIAL FINISH
ABBREVIATIONS, SEE MATERIAL
LEGEND ON ROOM FINISH SHEETS.
ARCHITECTURAL
A2.00 FIRST FLOOR DEMOLITION PLAN
A2.10 FIRST FLOOR PLAN
A3.00 DOOR / ROOM SCHEDULES
A3.10 FRAME TYPES
GENERAL
0.00 COVER SHEET
ADA COUNTY PROJECT #: 26044
M R
K D
A T
E D
E S
C R
IP
T
IO
N benb Image
DEMOLITION FLOOR PLAN
A2.10
C2
A2.10C3
A2.10 C1
1 1 1 1
5 2 5 5 5 2
44444
DEMOLITION FLOOR PLAN
6 2
STATE OF IDAHO
LICENSED
ARCHITECT
AR-985148
MARK W. HEAZLE
651 2 3
651 2 3
B
C
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
A
D
E
CONSULTANTS:
PHASE:
COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, INC.
is unlawful and subject to criminal prosecution.
STAMP:
4/10/2026
/1
/2
:2 :0
A
M C
U s e rs
\b e n b \D o c u m e n ts \2
.0
A d a C o u n ty
S to re fr o n t R e p la c e m e n t_ C
E N
T R
A L
R b e n b lc a rc h .c o m
.r v t
A2.00
26300.01
Author
Checker
ADA COUNTY -
ADA COUNTY
PROJECT #26044
FIRST FLOOR
DEMOLITION PLAN
4/10/2026
ADA COUNTY
CIVIC PLAZA
STORE FRONT
REPLACEMENT
PROJECT 2026
CONSTRUCTION
DOCUMENTS
1/8" = 1'-0"E1 252 E FRONT ST DEMO PLAN
DEMOLITION NOTES
1. PRIOR TO BEGINNING DEMOLITION, A SURVEY OF THE PROPOSED
DEMOLITION AREA SHALL BE MADE BY THE CONTRACTOR TO DETERMINE
THE CONNECTIONS, FRAMING METHODS, AND CONDITIONS OF THE
AREAS TO BE DISMANTLED.
2. ALL DEMOLISHED MATERIALS SHALL BE PROPERLY DISPOSED OF IN
ACCORDANCE WITH ALL LAWS AND REGULATIONS. CONTRACTOR TO PAY
ALL DUMPING FEES. ALL ITEMS THE OWNER DESIRES TO SALVAGE SHALL
BE IDENTIFIED PRIOR TO DEMOLITION.
3. COORDINATE WITH ELECTRICAL WORK TO BE REMOVED. VERIFY ALL
ROUTING AND CONNECTIONS OF ALL LINES PRIOR TO REMOVAL.
4. DEMOLITION DRAWINGS ARE BASED ON THE LATEST FIELD
VERIFICATION, HOWEVER THE CONTRACTOR AND ITS SUBCONTRACTORS
SHALL VERIFY ALL CONDITIONS PRIOR TO THE START OF DEMOLITION.
5. VERIFY ALL EXISTING CONDITIONS AND REPORT ANY DISCREPANCIES TO
ARCHITECT PRIOR TO PROCEEDING WITH WORK.
6. TAKE NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING BUILDING
CONDITIONS AND ELEMENTS THAT ARE TO REMAIN. PATCH AND REPAIR
AS NECESSARY ALL DAMAGED CONDITIONS.
7. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO ALL
APPLICABLE STATE AND LOCAL CODES, LAWS, AND REGULATIONS AND
SHALL CONFORM TO THE 2018 I.B.C.
8. THE PUBLIC SHALL BE PROTECTED FROM DEMOLITION MATERIAL, DUST,
FUMES, ETC. BY BARRIERS AND/OR PLASTIC SHEETS AS REQUIRED.
DEMOLITION WORK SHALL CEASE IF THE PUBLIC IS ENDANGERED IN ANY
WAY.
9. CONTRACTOR SHALL SECURE THE PROJECT AREA FROM
UNAUTHORIZED ACCESS AT ALL TIMES. COORDINATE WITH OWNER.
KEYNOTES#
1. EXISTING AWNING ABOVE. AWNING TO BE REMOVED AND STORED
ON-SITE DURING STOREFRONT REPLACEMENT. TAKE CAUTION TO
PROTECT AWNING. EXISTING STRUCTURES THAT ARE DAMAGED
DURING THE COURSE OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED. SEE DETAIL E1/A3.10.
2. EXISTING STOREFRONT, GLAZING, DOOR, FRAME AND ASSOCIATED
HARDWARE TO BE REMOVED.
3. EXISTING INTERIOR FINISHES TO REMAIN. PROTECT DURING
CONSTRUCTION.
4. EXISTING FLOORING THIS AREA TO REMAIN. PROTECT EXISTING
FLOORING DURING STOREFRONT DEMOLITION.
5. EXISTING STOREFRONT FRAMING AND GLAZING TO BE REMOVED.
6. EXISTING AWNING AT THIS LOCATION CAN BE UNBOLTED FROM THE
FACADE, LOWERED AND STORED ON SITE DURING THE
STOREFRONT REPLACEMENT. FIELD VERIFY IF AWNING NEED TO BE
REMOVED TO ACCOMPLISH THE STOREFRONT REPLACEMENT.
1/8" = 1'-0"C5 190 E FRONT DEMO PLAN
M R
K D
A T
E D
E S
C R
IP
T
IO
N
LEGEND
EXISTING WALL TO REMAIN - PAINT
X WINDOW FRAME TYPE - SEE SHEET A3.10
DOOR TAG - SEE DOOR SCHEDULE SHEET A3.00101
12' - 11" 9' - 11" 10' - 11 1/2" 8' - 0" 8' - 0" 10' - 11 1/2"
/2
S1
S2
S3 S4 S5 S6 S6 S7
A2.10
C2
A2.10C3
/2
147146 A2.10
C1
111111
1. PATCH AND REPAIR ALL EXISTING INTERIOR AND EXTERIOR FINISHES
DAMAGED DURING INSTALLATION AND/OR REMOVAL OF STORE FRONT
WINDOWS.
2. FIELD VERIFY ALL DIMENSIONS PRIOR TO ORDERING OR FABRICATING
STOREFRONT SECTIONS.
3. BUILDING MUST BE SECURE AT THE END OF THE WORKDAY. ALL
OPENINGS TO BE SECURED WITH TEMPORARY WALLS OR HAVE THE
NEW STOREFRONT IN PLACE AND NOT LEFT OPEN OVERNIGHT.
4. B1 AND C5 INDICATE LOCATIONS OF EXISTING STOREFRONT TO BE
REMOVED AND REPLACED. CONTRACTOR TO DEMO EXISTING STORE
FRONT.
GENERAL NOTES
FLOOR 1
0' - 0"
6" 12' - 8"
/2
/2
S9
084113.A
088000.I
084229.23
FLOOR 1
0' - 0"
6" 4' - 0"
FIELD VERIFY
9 17/32"
S10
S10
084113.A
088000.I
084113.A
088000.I
FLOOR 1
0' - 0"
6"2' - 2 1/2"
S10
S8
084113.A
088000.F
084113.A
088000.F
088000.F
21' - 0"
S11
STATE OF IDAHO
LICENSED
ARCHITECT
AR-985148
MARK W. HEAZLE
651 2 3
651 2 3
B
C
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
A
D
E
CONSULTANTS:
PHASE:
COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, INC.
is unlawful and subject to criminal prosecution.
STAMP:
4/10/2026
/1
/2
:2 :0
A
M C
U s e rs
\b e n b \D o c u m e n ts \2
.0
A d a C o u n ty
S to re fr o n t R e p la c e m e n t_ C
E N
T R
A L
R b e n b lc a rc h .c o m
.r v t
A2.10
26300.01
Author
Checker
ADA COUNTY -
ADA COUNTY
PROJECT #26044
FIRST FLOOR PLAN
4/10/2026
ADA COUNTY
CIVIC PLAZA
STORE FRONT
REPLACEMENT
PROJECT 2026
CONSTRUCTION
DOCUMENTS
CONDOC
1/8" = 1'-0"B1 252 E FRONT PLAN
084113.A ALUMINUM STOREFRONT FRAMING.
084229.23 SLIDING AUTOMATIC ENTRANCES
088000.F COATED SPANDREL GLASS.
088000.I INSULATING-GLASS UNITS.
KEYNOTES#
1. EXISTING AWNING ABOVE. AWNING TO BE REMOVED AND STORED
ON-SITE DURING STOREFRONT REPLACEMENT. TAKE CAUTION TO
PROTECT AWNING. EXISTING STRUCTURES THAT ARE DAMAGED
DURING THE COURSE OF CONSTRUCTION SHALL BE REPAIRED OR
REPLACED. SEE DETAIL E1/A3.10.
2. BRAKE METAL.
3. SIGNAGE BY OWNER.
4. NEW FLOORING IN THIS AREA. OWNER TO SUPPLY FLOORING.
5. RE-INSTALL AWNING IF REMOVED DURING CONSTRUCTION.
1/4" = 1'-0"C2 OPS ENTRY SOUTH
1/4" = 1'-0"C3 OPS ENTRY EAST
1/4" = 1'-0"C1 OPS ENTRY WEST
1/8" = 1'-0"C5 PARTIAL 190 E FRONT PLAN
M R
K D
A T
E D
E S
C R
IP
T
IO
N
1. DOOR OPENING.
2. SEE DOOR TYPES THIS SHEET.
3. DOOR CONSTRUCTION:
AL = ALUMINUM
4. FACING AND FINISH:
AN = ANODIZED
5. GLASS: SEE GLAZING TYPES BELOW.
6. FIRE RATING IN MINUTES
7. SEE DOOR FRAME TYPES SHEET A3.10
A. SEE WINDOW FRAME TYPES FOR DOORS IN WINDOW
FRAME ASSEMBLIES.
8. FRAME CONSTRUCTION:
AL = ALUMINUM
9. REMARKS:
1. ELECTRIC STRIKE WITH ACCESS CONTROL, COORDINATE WITH
EXISTING ELECTRICAL WIRING.
10. HARDWARE REMARKS:
A. NEW DOOR HARDWARE TO MATCH EXISTING DOOR HARDWARE
FUNCTIONALITY. THE DOOR HARDWARE SCHEDULE WAS
PROVIDED AS AN EXAMPLE OF A TYPICAL INSTALLATION. FIELD
VERIFY EXISTING DOOR HARDWARE.
DOOR LEGEND
DOOR TYPES
5" 5"
FG (SINGLE)
FG2 (DOUBLE)
LOCKSET/CYLINDERS: BEST 9K SERIES (LEVER HANDLE)
L1 KEYED CONSTRUCTION CYLINDERS,
PERMANENT CORES WILL BE SUPPLIED BY
OWNER.
HINGES: IVES
H1 5BB1 4-1/2” X 4-1/2” (PROVIDE NON-REMOVABLE
PINS AT OUT-SWINGING DOORS WITH LOCKS)
EH 5BB1TW 4-1/2” X 4-1/2” (PROVIDE ONE AT EACH
LEAF AND TWO H2)
EXIT DEVICE: VON DUPRIN
ED1 98L-NL
ELECTRIC STRIKE HESS
ES1 9400
CLOSER: LCN
C1 1461 CUSH, CUSH-N-STOP HEAVY DUTY
PARALLEL ARM (PUSH SIDE MOUNTING)
(INCLUDE NECESSARY MOUNTING BRACKETS)
DOOR POSITION SWITCH: SEE SPECIFICATION SECTION 281600 -
INTRUSION DETECTION AND ALARM SYSTEMS
DP PREP DOORS AND FRAMES - PROVIDE 3/4"⌀
CORE FOR DOOR POSITION SWITCH
HARDWARE
POWER SUPPLY: SCHLAGE
PS PS900 SERIES
PUSH/PULL: ROCKWOOD
P2 BF158 (WITH THROUGH DOOR MOUNTING)
SILENCERS: ROCKWOOD
SL 608-RKW (PROVIDE THREE PER DOOR)
FLUSH BOLT: IVES
FB FB458
DUST PROOF STRIKE: IVES
DPS DP1/DP2
ASTRAGAL: ZERO
AST 383AA
DOOR HARDWARE
EDW300
4 1/2"
HEAD
11'6"
084113.A
079200.A1
SHIM
EDW310
084113.A
SHIM
(EACH SIDE)
079200.A1
EDW031
088000.A
084113.A
079200.A1
084113.G1
1" 4 1/2"
EDW010
088000.A
084413.A
084413.A
084113.D
4 1/2"
BREAK METAL
ADAPTORS BY
STOREFRONT MFG.
084113.A
EDW025
088000.A
/2
4 1/2"
084113.H
084113.H
079200.A1
(EACH SIDE, TYP.)
088000.A
084113.A
072100.A1
079200.A1
EDW030
088000.A
084113.D
084113.E
SET IN FULL BED
OF MASTIC
CYLINDERS: KAWNEER
L1 KEYED CONSTRUCTION CYLINDERS BOTH SIDES, PERMANENT CORES WILL BE SUPPLIED BY OWNER.
PIVOTS: KAWNEER
H-1 SINGLE ACTING TOP, INTERMEDIATE AND BOTTOM OFFSET PIVOTS.
ELECT. POWER TRANS: VON DUPRIN
EPT1 EPT-10
EXIT DEVICE: VON DUPRIN
ED1 98L - NL
DEADLOCK: KAWNEER
MS ADAMS RITE MS-1850 DEADLOCK
ADAMS RITE 4089 LOCK INDICATOR W/“DOOR TO REMAIN OPEN…” DECAL
CLOSER: LCN
C1 4041-SP-CUSH
4040-18PA DROP PLATE
RELAY MODULE ALTRONIX
RE RB5 RELAY (BREAKS CONTACT IN ACTUATOR WITH MAG LOCK).
SEE ELECTRICAL FOR ADDITIONAL INFORMATION.
MAGNETIC LOCK SECURITY DOOR CONTROLS
ML 1561 SURFACE-MOUNTED (INCLUDE MOUNTING & ADJUSTMENT BRACKETS)
DOOR POSITION SWITCH SEE SPECIFICATION SECTION 281600 - INTRUSION DETECTION AND ALARM SYSTEMS
DP PREP DOORS AND FRAMES - PROVIDE 3/4"⌀ CORE FOR DOOR POSITION SWITCH HARDWARE.
PULL ROCKWOOD
P1 BF158 (WITH THROUGH DOOR MOUNTING)
THRESHOLD: PEMKO
T1 MODEL 270 A
WEATHERSEAL: KAWNEER
W1 SINGLE ACTING: SEALAIR WEATHERING SYSTEM IN THE DOOR AND FRAME CONSISTING OF A DENSE, BULB
POLYMERIC MATERIAL, WHICH REMAINS RESILIENT AND RETAINS ITS WEATHERING ABILITY UNDER TEMPERATURE EXTREMES, COMPLETE WITH EPDM BLADE GASKET SWEEP STRIP APPLIED TO THE BOTTOM
DOOR RAIL WITH CONCEALED FASTENERS.
ALUMINUM FRAMED ENTRANCES AND STOREFRONTS
TYPE 1:1" INSULATED - TINTED EXTERIOR PANE CLEAR INTERIOR PANE,
TEMPERED WHERE INDICATED OR REQUIRED (088000)
INDICATES TEMPERED GLASS, SEE SPECIFICATION
SECTION (088000) (BOTH PANES WHERE APPLICABLE)
GLAZING TYPES
INDICATES SPANDREL GLASS, SEE SPECIFICATION
SECTION (088000) (BOTH PANES WHERE APPLICABLE)
STATE OF IDAHO
LICENSED
ARCHITECT
AR-985148
MARK W. HEAZLE
651 2 3
651 2 3
B
C
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
A
D
E
CONSULTANTS:
PHASE:
COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, INC.
is unlawful and subject to criminal prosecution.
STAMP:
4/10/2026
/1
/2
:2 :0
A
M C
U s e rs
\b e n b \D o c u m e n ts \2
.0
A d a C o u n ty
S to re fr o n t R e p la c e m e n t_ C
E N
T R
A L
R b e n b lc a rc h .c o m
.r v t
A3.00
26300.01
Author
Checker
ADA COUNTY -
ADA COUNTY
PROJECT #26044
DOOR / ROOM
SCHEDULES
4/10/2026
ADA COUNTY
CIVIC PLAZA
STORE FRONT
REPLACEMENT
PROJECT 2026
CONSTRUCTION
DOCUMENTS
DOOR SCHEDULE
MARK
SEE DOOR LEGEND
9. Remarks
10. HARDWARE
REMARKS
1. DOOR OPENING
. D
O O
R T
Y P
E
. D
O O
R C
O N
S T
. F
A C
IN
G
F
IN
IS
H
. G
L A
S S
. F
IR
E
R A
T
IN
G
. F
R A
M E
T Y
P E
. F
R A
M E
C O
N S
T
DETAILS - SEE THIS SHEET U.O.N.
WIDTH HEIGHT HEAD JAMB SILL
146 6' - 2 1/2" 7' - 11" FG2 AL FF 1 - - AL E1 E2 E3 1 A
147 6' - 2 1/2" 7' - 11" FG2 AL FF 1 - - AL E1 E2 E3 1 A
154 12' - 4 1/2" 7' - 10" - - - SLIDING
AUTOMATIC
A
156 3' - 6" 7' - 11" FG AL FF 1 - - AL E1 E2 E3 1 A
155 12' - 4 1/2" 7' - 10" - - - SLIDING
AUTOMATIC
A
GENERAL DOOR NOTES
1. ALL DOORS AND WINDOWS SHALL BE CONSTRUCTED AS DETAILED TO
ACTUAL OPENING DIMENSIONS, FIELD VERIFY ALL DIMENSIONS PRIOR TO
FABRICATION.
2. ALL RATED DOORS SHALL BEAR APPROVAL AGENCY RATING LABLES.
3. DOOR FRAMES AND HARDWARE ON RATED DOORS SHALL BE LISTED
FOR THOSE RATINGS.
4. ALL RATED DOORS ASSEMBLIES TO HAVE CLOSERS (SPRING HINGES
NOT ALLOWED) AND BE SELF LATCHING OR AUTOMATIC CLOSING.
5. DOORS IN 6'-0" WIDE OPENINGS ARE TYPICALLY PAIRS OF 3'-0" DOORS.
REFER TO DOOR TYPES (THIS SHEET) AND PLANS FOR FURTHER
CLARIFICATION.
6. REFER TO SHEET A3.00 FOR COMPLETE HARDWARE
REQUIREMENTS AT EACH GROUP/OPENING.
7. SEE SHEET A3.10 FOR DOORS OCCURRING IN WINDOW FRAME TYPES.
8. PROVIDE TEMPERED GLASS IN DOORS, WINDOW LIGHTS, AND ADJACENT
TO DOOR AND GLAZING WITHIN 36" FROM WALKING SURFACE AND TO
MEET ALL OTHER REQUIRMENTS OF IBC SECTION 2406.
072100.A1 EXTRUDED POLYSTYRENE BOARD INSULATION.
079200.A1 SEALANT OVER BACKER ROD.
084113.A ALUMINUM STOREFRONT FRAMING.
084113.D ENTRANCE DOOR.
084113.E ENTRANCE DOOR HARDWARE.
084113.G1 SILL FLASHING.
084113.H ALUMINUM BRAKE SHAPE
084413.A GLAZED ALUMINUM CURTAIN WALL.
088000.A GLASS, SEE LEGEND FOR TYPE.
CONDOC
3" = 1'-0"E1 HEAD DETAIL
3" = 1'-0"E2 JAMB DETAIL
3" = 1'-0"E3 SILL DETAIL
3" = 1'-0"E4 HEAD / SILL DETAIL
3" = 1'-0"E5 JAMB DETAIL
3" = 1'-0"E6 SILL DETAIL
M R
K D
A T
E D
E S
C R
IP
T
IO
N
TYPE 1:1" INSULATED - TINTED EXTERIOR PANE CLEAR INTERIOR PANE,
TEMPERED WHERE INDICATED OR REQUIRED (088000)
INDICATES TEMPERED GLASS, SEE SPECIFICATION
SECTION (088000) (BOTH PANES WHERE APPLICABLE)
GLAZING TYPES
INDICATES SPANDREL GLASS, SEE SPECIFICATION
SECTION (088000) (BOTH PANES WHERE APPLICABLE)
S1
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
18' - 7"
4' - 3 1/4" 5' - 0 1/4" 5' - 0 1/4" 4' - 3 1/4"
E1
A3.00
E2
A3.00
E3
A3.00 S2
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
11' - 2 1/2"
5' - 7 1/4" 5' - 7 1/4"
E1
A3.00
E2
A3.00
E3
A3.00
S3
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
12' - 11"
4' - 0 1/2" 4' - 10" 4' - 0 1/2"
E1
A3.00
E2
A3.00
E3
A3.00 S4
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
9' - 11"
1' - 9 9/32" 6' - 4 1/2" 1' - 9 7/32"
S C
H E
D U
L E
S E
E D
O O
R
E1
A3.00
E2
A3.00
E3
A3.00
S5
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
10' - 11 1/2"
5' - 3 11/16" 5' - 7 13/16"
E1
A3.00
E2
A3.00
E3
A3.00
S6
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
8' - 0"
4' - 0" 4' - 0"
E1
A3.00
E2
A3.00
E3
A3.00
S7
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
10' - 11 1/2"
2' - 3 17/32" 6' - 4 1/2" 2' - 3 15/32"
S C
H E
D U
L E
S E
E D
O O
R
E1
A3.00
E2
A3.00
E3
A3.00
S8
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
E2
A3.00
E1
A3.00
E4
A3.00
E3
A3.00
3' - 2" 6' - 4" 3' - 2"
S9
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
E1
A3.00
E2
A3.00
E4
A3.00
S10
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
E2
A3.00
E1
A3.00
E4
A3.00
E3
A3.00
4' - 0"
21' - 0"
S11
ALUMINUM FRAME
4 1/2" STOREFRONT
TYPE 1 GLAZING
2' - 7"3' - 2"3' - 2"3' - 2"3' - 2"3' - 2"2' - 7"
S C
H E
D U
L E
S E
E D
O O
R
E1
A3.00
E2
A3.00
E3
A3.00
ED01
REMOVAL RE-ATTACHMENT
4 6 5
9 9
10 10
13 13
STATE OF IDAHO
LICENSED
ARCHITECT
AR-985148
MARK W. HEAZLE
651 2 3
651 2 3
B
C
JOB N0.:
CHECKED BY:
SHEET NO.
DRAWN BY:
DATE:
A
D
E
CONSULTANTS:
PHASE:
COPYRIGHT All rights reserved. Reproduction or use in any form or by any means -- graphic, electronic, mechanical, etc. -- without written permission of LOMBARD - CONRAD ARCHITECTS, INC.
is unlawful and subject to criminal prosecution.
STAMP:
4/10/2026
/1
/2
:2 :0
A
M C
U s e rs
\b e n b \D o c u m e n ts \2
.0
A d a C o u n ty
S to re fr o n t R e p la c e m e n t_ C
E N
T R
A L
R b e n b lc a rc h .c o m
.r v t
A3.10
26300.01
Author
Checker
ADA COUNTY -
ADA COUNTY
PROJECT #26044
FRAME TYPES
4/10/2026
ADA COUNTY
CIVIC PLAZA
STORE FRONT
REPLACEMENT
PROJECT 2026
CONSTRUCTION
DOCUMENTS
GENERAL NOTES
1. SEE SHEET A3.00 FOR STANDARD HARDWARE.
2. ALL DOORS AND WINDOWS SHALL BE CONSTRUCTED AS DETAILED TO
ACTUAL OPENING DIMENSIONS, FIELD VERIFY.
3. SEE SPECIFICATION FOR DOOR AND FRAME ASSEMBLIES SCHEDULED
TO RECEIVE CONDUIT FOR LATCH MECHANISMS AND POSITION
INDICATORS.
4. INSTALL SEALANT BETWEEN DISSIMILAR MATERIALS.
5. ALL GLASS WITHIN A RATED ASSEMBLY SHALL MEET OR EXCEED
REQUIRED FIRE RATINGS AND SAFETY GLASS STANDARDS. GLASS
SHALL BE LABELED AS SUCH OR PROVIED WITH A CERTIFICATE FROM
THE MANUFACTURER STATING THAT EACH INDIVIDUAL PIECE OF GLASS
MEETS FIRE AND SAFETY GLASS STANDARDS.
KEYNOTES#
1. REMOVE EXISTING ROLLER SHADES, SALVAGE FOR RE-
INSTALLATION AFTER THE STOREFRONT HAS BEEN REPLACED.
AFTER STOREFRONT REPLACEMENT, RE-INSTALL WINDOW SHADES
TO SAME LOCATION THEY WERE REMOVED FROM.
2. EXISTING CONDITIONS. FIELD VERIFY LOCATION OF EXISTING STORE
FRONT FRAMING IN EXISTING WALL OPENINGS. NEW STORE FRONT
TO BE LOCATED IN THE SAME PLACE. PATCH AND REPAIR ANY
DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES TO EXISTING
ADJACENT CONDITIONS.
3. REMOVE INTERIOR GYPSUM BOARD, VAPOR BARRIER AND
INSULATION, AND EXTERIOR SHEATHING AS NECESSARY TO
PROVIDE ACCESS TO THE AWNING SUPPORT LEGS.
4. SUPPORT THE AWNING AS NECESSARY. CUT AWNING 3" DIAMETER
SUPPORT LEGS. LOWER AWNING OUT OF THE HOLES IN THE SOFFIT.
5. AFTER THE STOREFRONT HAS BEEN REPLACED, RAISE THE AWNING
INTO PLACE. WELD A TUBE STEEL SLEEVE WITH A 5/16" FILLET WELD
CONTINUOUS AROUND THE TOP AND BOTTOM OF THE SLEEVE TO
THE AWNING SUPPORT LEGS. SLEEVE INSIDE DIAMETER TO MATCH
OUTSIDE DIAMETER OF THE AWNING SUPPORT. CONTRACTORS
OPTION, THE AWNING SUPPORT LEGS CAN ALSO BE WELDED WITH A
PARTIAL PENETRATION WELD WITHOUT THE SLEEVES.
6. REPLACE GYPSUM BOARD WHERE IT WAS REMOVED TO ACCESS
THE AWNING SUPPORTS. PATCH BACK AIR BARRIER, VAPOR
BARRIER, AND INSULATION TO MATCH EXISTING REMAINING WALL
CONDITIONS.
7. EXISTING STOREFRONT FRAMING TO BE REMOVED AFTER AWNING
REMOVAL.
8. NEW STOREFRONT FRAMING.
9. EXISTING TUBE STEEL AWNINGS TO BE REMOVED, SALVAGED, AND
REPLACED.
10. EXISTING EXTERIOR BUILDING FINISH TO REMAIN. PROTECT FROM
DAMAGE.
11. EXISTING SOFFIT TO REMAIN. PROTECT FROM DAMAGE.
12. EXISTING EXTERIOR WALL FRAMING AND SHEATHING TO REMAIN.
PROTECT FORM DAMAGE.
13. EXISTING CEILING. REMOVE EXISTING CEILING TILES TO GAIN
ACCESS TO THE EXTERIOR WALL ASSEMBLY AS NECESSARY.
SALVAGE TILES. RE-INSTALL CEILING AFTER EXTERIOR WALL WORK
IS COMPLETED.
14. ASSUMED AWNING SUPPORT STRUCTURE TO REMAIN. PROTECT
FROM DAMAGE.
15. NEW FLOORING. MATCH EXISTING FLOORING OR USE FROM
OWNERS STOCK.
16. EXISTING FLOORING TO REMAIN. PROTECT FROM DAMAGE.
1 1 1 1 1
1" = 1'-0"E1 AWNING DETAIL
1 1
M R
K D
A T
E D
E S
C R
IP
T
IO
N
| Sheets |
| 0.00 - COVER SHEET |
| A2.00 - FIRST FLOOR DEMOLITION PLAN |
| A2.10 - FIRST FLOOR PLAN |
| A3.00 - DOOR / ROOM SCHEDULES |
| A3.10 - FRAME TYPES |
File details come from the government source that posted it. Updated .