2-Asbestos Survey Reeves Co 700 W Daggett 02122026.pdf

PDF 3 MB Posted

Attached to
Asbestos Removal
Solicitation number
26-014
Issued by
Polk County, Texas

About this file

This is an Asbestos Survey Report prepared by E-Tech Environmental and Safety Solutions, Inc. for Reeves County regarding the Annex 1 building located at 700 W. Daggett Street in Pecos, Texas. The survey was conducted on February 2-3, 2026, with the report finalized on February 12, 2026. The inspection identified asbestos-containing materials (ACM) in thirteen building materials across the facility, including plaster ceiling (approximately 500 square feet), exterior window caulk and glazing (approximately 10 square feet each), six varieties of resilient floor tile with black mastic (totaling approximately 6,710 square feet), boiler insulation (approximately 200 square feet), pipe insulation (approximately 1,000 square feet), duct insulation (approximately 400 square feet), and Transite wall panels (approximately 320 square feet). A total of 68 bulk samples were collected from 20 homogeneous materials and submitted to J3 Resources in Houston, Texas for polarized light microscopy (PLM) analysis using EPA-approved methodology with a 72-hour turnaround time.

The survey results indicate that asbestos removal shall be performed by a State of Texas licensed asbestos abatement contractor employing licensed workers, with the property owner required to contract with a State of Texas licensed Asbestos Consulting Agency prior to renovation to design the abatement plan and conduct required air monitoring. A copy of the survey must be maintained on-site during all asbestos abatement and renovation activities. The report was prepared by Jimmy W. McNeil, Jr. (Texas Asbestos Inspector License #60-2130, expires 2/28/2028) and reviewed by Ronnie Matte (Texas Individual Asbestos Consultant License #10-5771, expires 2/13/2028). The analytical work was conducted by Eurofins Built Environment Testing Central, LLC, which is NVLAP accredited for bulk PLM asbestos analysis.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. Box 62228 Midland • TX • 79711 • Tel: 432-563-2200 • Fax: 432-563-2213

Environmental & Safety Solutions, Inc.

Asbestos Survey Report

Presented To:

Reeves County

31 County Road 201

Pecos, Texas 79772

Project:

Reeves County Annex 1

700 W. Daggett St.

Pecos, Texas 79772

E-Tech Project #725-23633-000

Inspection Date: 3 February 2026

Report Date: 12 February 2026

Written by, Reviewed and approved by, Jimmy W. McNeil, Jr. Ronnie Matte

Texas Asbestos Inspector Texas Individual Asbestos Consultant

License # 60-2130 License # 10-5771

Expires: 2/28/2028 Expires: 2/13/2028

Table of Contents

1.0 Executive Summary

2.0 Asbestos Bulk Sampling Methodology

3.0 Conclusions

4.0 Recommendations

5.0 Limitations

6.0 Use by Third Parties

7.0 Unidentifiable Conditions

Attachments

Attachment 1 - Asbestos Lab PLM Bulk Results

Attachment 2 - Chain of Custody

Attachment 3 - Homogenous Materials List

Attachment 4 - Site Diagrams

Attachment 5 - Copy of E-Tech License

1.0 Executive Summary

Reeves County retained E-Tech Environmental and Safety Solutions, Inc. to perform a limited asbestos survey of the materials that may be disturbed during the future demolition of the Annex 1 building located at 700 W. Daggett St. in Pecos, Texas.

On 2 and 3 February 2026, Wally McNeil of E-Tech performed a visual inspection and collected bulk samples of suspect asbestos containing materials throughout the building.

A total of sixty-eight (68) samples were collected from twenty (20) homogeneous materials.

The suspect asbestos containing materials were submitted under chain of custody for 72-hour turn around PLM analysis to J3 Resources in Houston, Texas. J3 Resources laboratory is NVLAP accredited for bulk PLM asbestos analysis. The analytical results indicate that thirteen (13) building materials contain greater than 1% asbestos. The materials reported to contain asbestos are identified as:

C01- Plaster ceiling

E01- Exterior window caulk

E02- Exterior window glazing

F01- 12”x 12” Beige, rock pattern, resilient floor tile with black mastic

F03- 9”x 9” Beige w/multi streaks, resilient floor tile with black mastic

F04- 12”x 12” Tan w/blue streaks, resilient floor tile with black mastic

F05- 12”x 12” White w/dark streaks, resilient floor tile with black mastic

F06- 9”x 9” Beige, broken rock pattern, resilient floor tile with black mastic

F07- 9”x 9” Beige w/green streaks, resilient floor tile with black mastic

I01- Boiler insulation

I02- Pipe insulation

I03- Duct insulation

W03- Transite wall panels

2.0 Asbestos Bulk Sampling Methodology

Suspect asbestos bulk samples were collected and placed in zip-lock bags for laboratory analysis. The sampling was performed to identify asbestos in specific suspect asbestos containing materials. The samples were submitted for 72-hour turn-around time analysis via polarized light microscopy (PLM).

The PLM method is the most commonly used method to analyze building materials for the presence of asbestos. The PLM method is in accordance with the EPA Interim

Method of the Determination of Asbestos in Bulk Samples. This method utilizes the optical properties of minerals to identify the selected constituent. The use of this method enables identification of the type and the percentage of asbestos in a sample.

The detection limit of the PLM method for asbestos identification is approximately one percent asbestos. At the request of the client, point count analysis may be considered for samples determined to contain less than ten percent asbestos when analyzed via PLM.

3.0 Conclusions

The following materials tested positive for asbestos:

C01- Plaster ceiling (Approx. 500 ft2).

E01- Exterior window caulk (Approx. 10 ft2).

E02- Exterior window glazing (Approx. 10 ft2).

F01- 12”x 12” Beige, rock pattern, resilient floor tile with black mastic (Approx.

680 ft2).

F03- 9”x 9” Beige w/multi streaks, resilient floor tile with black mastic (Approx.

1,545 ft2).

F04- 12”x 12” Tan w/blue streaks, resilient floor tile with black mastic (Approx.

480 ft2).

F05- 12”x 12” White w/dark streaks, resilient floor tile with black mastic

(Approx. 1,315 ft2).

F06- 9”x 9” Beige, broken rock pattern, resilient floor tile with black mastic

(Approx. 160 ft2).

F07- 9”x 9” Beige w/green streaks, resilient floor tile with black mastic (Approx.

2,530 ft2).

I01- Boiler insulation (Approx. 200 ft2).

I02- Pipe insulation (Approx. 1,000 ft2).

I03- Duct insulation (Approx. 400 ft2).

W03- Transite wall panels (Approx. 320 ft2).

4.0 Recommendations

The asbestos containing building materials may be left in place as long as they are in good condition and will not be disturbed.

Removal of ACM materials shall be performed by State of Texas licensed asbestos abatement contractor employing licensed workers.

The owner of the property shall contract with State of Texas licensed Asbestos

Consulting Agency prior to renovation to design the asbestos abatement and conduct required air monitoring.

A copy of this survey shall be kept on site during the asbestos abatement and renovation activities.

If suspect asbestos containing materials, other than those already tested, are encountered, they must be assumed to contain asbestos or tested and proven otherwise.

5.0 Limitations

The field observations, measurements and research reported herein are considered sufficient in detail and scope to determine the asbestos content of the tested materials at the subject property on the date of the inspection. The assessment, conclusions and recommendations presented herein are based upon specifically limited data. They do not represent all conditions at the subject property. E-Tech warrants the findings and conclusions contained herein have been promulgated in accordance with generally accepted industrial hygiene methodology and only for the site described in this report.

6.0 Use by Third Parties

This report was prepared pursuant to the agreement between E-Tech and Reeves County.

The agreement relationship included an exchange of information about the subject property. Reliance or any use of this report by anyone other than the client, for whom it was prepared, is prohibited and therefore not foreseeable to E Tech.

Reliance on or use by any such third party without explicit authorization of the report does not make said third party a third-party beneficiary to E-Tech’s agreement with the client. Any such unauthorized reliance on or use of this report, including any of its information or conclusions, will be at third party’s risk. For the same reasons, no warranties or representations, expressed or implied in this report, are made to any such third party.

7.0 Unidentifiable Conditions

This asbestos related environmental consulting report has been developed to provide the client with information regarding apparent conditions related to limited accessible building materials in the subject property. Although E Tech believes that the findings and conclusions provided in this report are reasonable, the assessment is necessarily limited to the conditions observed and to the information available at the time of the inspection. Due to the nature of the work, there is a possibility conditions exist that could not be identified within the scope of the assessment or which were not apparent at the time it was conducted. It is also possible that the testing methods employed at the time of the report may later be superseded by other methods. E-Tech does not accept responsibility for changes in the state of the art.

We have employed state-of-the-art practices to perform this analysis of risk and identification, but this evaluation is limited in scope to the areas listed above. Our services consist of professional opinions and recommendations made in accordance with generally accepted engineering principles and practices.

Attachments

Attachment 2 - Chain of Custody

Attachment 3 - Homogenous Materials List

Approved by:

Business Unit Manager Scott Ward

Report for:

Wally McNeil Etech Environmental & Safety Solutions, Inc.

P.O. Box 62228 Midland, TX 79711

Regarding:

Eurofins Built Environment Testing Central, LLC Project: 23633; 700 W. Daggett St., Pecos, TX

EML ID: 4402577

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing Central, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM (Layer %): 02-09-2026

Service SOPs: Asbestos PLM (Layer %) (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 200525-0

EMLab ID: 4402577, Page 1 of 12Eurofins Built Environment Testing Central, LLC

Eurofins Built Environment Testing Central, LLC 3113 Red Bluff Road, Pasadena, TX 77503 713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

01.

22080499-1

Layer 1 White Wrap Homogeneity:Good

Not Detected 90% Non-Fibrous Material 10% Cellulose

Layer 2 White Insulation Homogeneity:Good

10% Amosite 6% Crocidolite 2% Chrysotile

82% Non-Fibrous Material

02.

22080500-1

Layer 1 White Wrap Homogeneity:Good

Homogeneity:Good

10% Amosite 6% Crocidolite 2% Chrysotile

82% Non-Fibrous Material

03.

22080501-1

Layer 1 White Wrap Homogeneity:Good

Homogeneity:Good

10% Amosite 6% Crocidolite 2% Chrysotile

82% Non-Fibrous Material

04.

22080502-1

Layer 1 White Wrap Homogeneity:Good

Homogeneity:Good

12% Chrysotile 88% Non-Fibrous Material

05.

22080503-1

Layer 1 White Wrap Homogeneity:Good

Homogeneity:Good

12% Chrysotile 88% Non-Fibrous Material

06.

22080504-1

Layer 1 White Wrap Homogeneity:Good

Comments:

EMLab ID: 4402577, Page 2 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

06.

22080504-1(cont.)

Layer 2 Brown Wrap Homogeneity:Good

Not Detected 100% Cellulose

Layer 3

Homogeneity:Good

12% Chrysotile 88% Non-Fibrous Material

07.

22080505-1

Layer 1 Gray Transite Homogeneity:Good

10% Chrysotile 90% Non-Fibrous Material

08.

22080506-1

Layer 1 Gray Transite Homogeneity:Good

10% Chrysotile 90% Non-Fibrous Material

09.

22080507-1

Layer 1 Gray Transite Homogeneity:Good

10% Chrysotile 90% Non-Fibrous Material

10.

22080508-1

Layer 1 Silver Wrap with Black Mastic Homogeneity:Good

5% Chrysotile 90% Non-Fibrous Material 5% Cellulose

Black Coating Homogeneity:Good

Not Detected 95% Non-Fibrous Material 5% Glass Fibers

Yellow Insulation Homogeneity:Good

Not Detected 98% Mineral Wool 2% Non-Fibrous Material

11.

22080509-1

Layer 1 Silver Wrap with Black Mastic Homogeneity:Good

Black Coating Homogeneity:Good

Homogeneity:Good

12.

22080510-1

Layer 1 Silver Wrap with Black Mastic Homogeneity:Good

EMLab ID: 4402577, Page 3 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

12.

22080510-1(cont.)

Layer 2 Black Coating Homogeneity:Good

Homogeneity:Good

13.

22080511-1

Layer 1 White Floor Tile

3% Chrysotile 97% Non-Fibrous Material

Black Mastic Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

14.

22080512-1

Layer 1 White Floor Tile

Not Detected 100% Non-Fibrous Material

Yellow Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

15.

22080513-1

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

16.

22080514-1

Layer 1 Green Floor Tile

5% Chrysotile 95% Non-Fibrous Material

Tan Floor Tile

Layer 4

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 4 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

17.

22080515-1

Layer 1 Green Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

18.

22080516-1

Layer 1 Green Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

19.

22080517-1

Layer 1 Gray Floor Tile

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 5 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

20.

22080518-1(cont.)

Layer 1 Gray Floor Tile

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

21.

22080519-1

Layer 1 Gray Floor Tile

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

22.

22080520-1

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

23.

22080521-1

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

24.

22080522-1

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

25.

22080523-1

Layer 1 White Floor Tile

Black/Yellow Mastic Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 6 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

26.

22080524-1(cont.)

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

27.

22080525-1

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

28.

22080526-1

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

29.

22080527-1

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

30.

22080528-1

Layer 1 White Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

31.

22080529-1

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 7 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Celina Villafranco Highlight

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

32.

22080530-1(cont.)

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

33.

22080531-1

Layer 1 Beige Floor Tile

Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

34.

22080532-1

Layer 1 Gray Floor Tile Homogeneity:Good

Not Detected 100% Non-Fibrous Material

35.

22080533-1

Layer 1 Gray Floor Tile

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

36.

22080534-1

Layer 1 Gray Floor Tile

Homogeneity:Good

Not Detected 100% Non-Fibrous Material

37.

22080535-1

Layer 1 Brown Mastic Homogeneity:Good

Not Detected 98% Non-Fibrous Material 2% Cellulose

38.

22080536-1

Layer 1 Brown Mastic Homogeneity:Good

39.

22080537-1

Layer 1 Brown Mastic Homogeneity:Good

EMLab ID: 4402577, Page 8 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

40.

22080538-1(cont.)

Layer 1 Beige Cove Base

White Cove Base Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

41.

22080539-1

Layer 1 Beige Cove Base

Brown Cove Base Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

42.

22080540-1

Layer 1 Beige Cove Base

Yellow Cove Base Mastic Homogeneity:Good

Not Detected 100% Non-Fibrous Material

43.

22080541-1

Layer 1 White Popcorn Ceiling Homogeneity:Good

Not Detected 100% Non-Fibrous Material

44.

22080542-1

Layer 1 White Popcorn Ceiling Homogeneity:Good

Not Detected 100% Non-Fibrous Material

45.

22080543-1

Layer 1 White Popcorn Ceiling Homogeneity:Good

Not Detected 100% Non-Fibrous Material

46.

22080544-1

Layer 1 Gray Caulk Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

47.

22080545-1

Layer 1 Gray Caulk Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

48.

22080546-1

Layer 1 Gray Caulk Homogeneity:Good

3% Chrysotile 97% Non-Fibrous Material

49.

22080547-1

Layer 1 White Window Glazing Homogeneity:Good

2% Chrysotile 98% Non-Fibrous Material

50.

22080548-1

Layer 1 White Window Glazing Homogeneity:Good

2% Chrysotile 98% Non-Fibrous Material

51.

22080549-1

Layer 1 White Window Glazing Homogeneity:Good

2% Chrysotile 98% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 9 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

52.

22080550-1

Layer 1 Brown Plaster Homogeneity:Good

6% Chrysotile 94% Non-Fibrous Material

53.

22080551-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

54.

22080552-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

55.

22080553-1

Layer 1 White Joint Compound Homogeneity:Good

Not Detected 100% Non-Fibrous Material

56.

22080554-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

57.

22080555-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

58.

22080556-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

59.

22080557-1

Layer 1 Black Roofing Material Homogeneity:Good

Not Detected 100% Non-Fibrous Material

60.

22080558-1

Layer 1 Black Roofing Material Homogeneity:Good

5% Synthetic Fibers

61.

22080559-1

Layer 1 Black Roofing Material Homogeneity:Good

Not Detected 100% Non-Fibrous Material

62.

22080560-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

63.

22080561-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

64.

22080562-1

Layer 1 White Joint Compound

Red Brick

Gray Mortar Homogeneity:Good

Not Detected 100% Non-Fibrous Material

65.

22080563-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

EMLab ID: 4402577, Page 10 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

Sample ID # Lab-ID version Sample Description Asbestos

Constituents Non-Asbestos Constituents Comment

66.

22080564-1

Layer 1 Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

67.

22080565-1

Layer 1 White Joint Compound

Beige Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

68.

22080566-1

Layer 1 White Joint Compound

Gray Plaster Homogeneity:Good

Not Detected 100% Non-Fibrous Material

Comments:

Analyst(s): Jason Hayward

EMLab ID: 4402577, Page 11 of 12Eurofins Built Environment Testing Central, LLC

The total percentage of sample components shown may be greater than 100% when some components are detected at <1%.

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers of that type were detected.

When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

713-290-0223 www.eurofinsus.com/Built

Client: Etech Environmental & Safety Solutions, Inc.

C/O: Wally McNeil Re: 23633; 700 W. Daggett St., Pecos, TX

Date of Sampling: 02-03-2026 Date of Receipt: 02-04-2026 Date of Report: 02-09-2026

Bulk Asbestos Fiber Analysis by Polarized Light Microscopy (PLM) Appx E Sub E 40 CFR 763 / EPA 600/R-93/116

PROJECT ANALYST AND SIGNATORY REPORT

Project Analyst

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Analyst: Jason Hayward

EMLab ID: 4402577, Page 12 of 12Eurofins Built Environment Testing Central, LLC

Attachment 2 - Chain of Custody

Attachment 3 - Homogenous Materials List

Homogeneous Material List

C01- Plaster ceiling

C02- Adhered acoustical ceiling tile glue dots

C03- Popcorn ceiling texture

E01- Exterior window caulk

E02- Exterior window glazing

F01- 12”x 12” Beige, rock pattern, resilient floor tile with black mastic

F02- Grey w/multi streaks, resilient sheet flooring

F03- 9”x 9” Beige w/multi streaks, resilient floor tile with black mastic

F04- 12”x 12” Tan w/blue streaks, resilient floor tile with black mastic

F05- 12”x 12” White w/dark streaks, resilient floor tile with black mastic

F06- 9”x 9” Beige, broken rock pattern, resilient floor tile with black mastic

F07- 9”x 9” Beige w/green streaks, resilient floor tile with black mastic

F08- 12”x 12” Beige w/multi streaks, resilient floor tile

I01- Boiler insulation

I02- Pipe insulation

I03- Duct insulation

R01- Rolled roofing

W01- Plaster walls

W02- Resilient cove base glue

W03- Transite wall panels

*Positive ACMs are Bolded and Highlighted

01 Asbestos Survey Report_rm
02 Attachments
03 Attachment 1
04 Project-4402577_23633
05 Attachment 2
06 COC-4402577
07 Attachment 3
08 Homogeneous Material List
09 Attachment 4
10 Floor Plans
11 Attachment 5
12 Asb Consultant Agency 2026
13 Wally Current License and Refreshers 10 2025

File details come from the government source that posted it. Updated .