This is a construction drawings document for the Dotters Corner Road, Southern End – Culvert Replacement Project being procured by Polk Township, Monroe County, Pennsylvania. The project involves the installation of an Aluminum Box Culvert with aluminum end walls, guide rails, and restoration of the stream channel and roadway. The scope of work includes excavation, culvert assembly and installation, stream bed restoration, paved roadway restoration, shoulder restoration, guide rail installation, and erosion and sediment controls. Sealed bids are being received via PennBid with a deadline of Thursday, September 3, 2026, at 2:00 PM. A pre-bid meeting is scheduled for Wednesday, August 19, 2026, at 11:00 AM at the project site along Dotters Corner Road; attendance is encouraged but not mandatory. Work is anticipated to commence upon receipt of General Permit approval from the Pennsylvania Department of Environmental Protection and procurement of the Aluminum Box Culvert through Costars. If environmental restrictions prohibit stream work between October 1st and April 1st, construction will be delayed until April 1, 2027. All work must be completed within 90 days of project commencement.
The Aluminum Box Culvert and aluminum end walls will be procured by Polk Township via Costars prior to construction start. All site construction, installation, and restoration work is included within the bid package. The contract documents and specifications, along with the construction drawings provided in this appendix, establish the requirements for project completion. All project documents are available at no cost through PennBid.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SH
EE
T:
O F
LOCATION MAP
PORTION OF POHOPOCO MOUNTAIN, PA.
QUADRANGLE MAP
SCALE 1" = 2000'
CONSTRUCTION NOTES:
1. THE CONTRACTOR SHALL FIELD VERIFY ALL ELEVATIONS AND FIELD CONDITIONS PRIOR TO ORDERING
ANY CONSTRUCTION MATERIALS FOR THIS PROJECT.
2. ALL UTILITY LINE LOCATIONS HAVE BEEN DETERMINED FROM POLK TOWNSHIP RECORD PLANS AND/OR
PAINT MARKINGS FROM THE PENNSYLVANIA ONE CALL SYSTEM DESIGN PHASE.
3. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH UNDERGROUND UTILITIES/AGENCIES, SUCH THAT UNDERGROUND INTERFERENCES ARE LOCATED AND AVOIDED PER PA ACT 187 OF 1996, AS
AMENDED.
4. THE CONTRACTOR SHALL PROPERLY MAINTAIN THE SITE DURING CONSTRUCTION SUCH THAT INJURIES
OR PROPERTY DAMAGE WILL NOT OCCUR. SHOULD ANY VEHICULAR DAMAGE, PROPERTY DAMAGE,
INJURY, OR OTHER TYPE OF MISHAP OCCUR DURING CONSTRUCTION DUE TO IMPROPERLY MAINTAINED AREAS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO AMEND THE DAMAGE AS SOON AS POSSIBLE.
5. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE RELOCATION OF ALL EXISTING ITEMS (I.E., UTILITY LINES, UTILITY POLES, SURVEY MONUMENTS, ETC.) WHICH WILL FALL WITHIN THE PROPOSED
IMPROVEMENTS AS INDICATED ON THE PLAN OR DISCOVERED IN THE FIELD.
6. ALL EXCAVATION WITHIN 3 FEET OF MARKED UTILITY LINES SHALL BE HAND DUG. MACHINE
EXCAVATION WITHIN THESE LIMITS IS STRICTLY PROHIBITED.
7. ALL PAVING AND CONSTRUCTION MATERIALS AND CONSTRUCTION THEREOF SHALL BE IN
CONFORMANCE WITH ALL APPLICABLE REQUIREMENTS OF PENN D.O.T. PUBLICATION 408/00 (OR LATEST
EDITION) SPECIFICATIONS.
8. ALL FINAL GRADES OF PROPOSED WORK SHALL EVENLY TIE INTO THE GRADES OF THE EXISTING
BRIDGE, PAVEMENT AND OTHER IMPROVEMENTS.
9. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ACTUAL SITE CONDITIONS AT THE TIME OF CONSTRUCTION ARE CONSISTENT WITH THE ASSUMED ALLOWABLE NEW SOIL BEARING PRESSURE OF 3,000 PSF AT THE BOTTOM OF THE FOUNDATION WITH A GEOTECHNICAL INVESTIGATION FROM A
QUALIFIED GEOTECHNICAL ENGINEER.
IMPROVEMENT AREA LOCATION MAP
CIVIL ENGINEERS & LAND SURVEYORS
KEYSTONE CONSULTING ENGINEERS, Inc.
CONTACTS AND UTILITIES
POLK TOWNSHIP
(ROAD MASTER)
TOWNSHIP ENGINEER
PROJECT MANAGER
ELECTRIC : PENNSYLVANIA POWER AND LIGHT GENERAL #
ERIC SNYDER
TIGHE MECKES
(610) 681-5376BRIAN AHNER
(800) 342-5775
(610) 681-5233
(610) 681-5233
POLK TOWNSHIP (610)-681-5376OFFICE
N
N
CONSTRUCTION PLANS
DOTTERS CORNER ROAD SOUTHERN END
CULVERT REPLACEMENT PROJECT
POLK TOWNSHIP
MONROE COUNTY, PENNSYLVANIA
AUGUST 13, 2026
PROJECT NOTES:
1. IT IS THE OWNER'S INTENTION TO AWARD THIS ENTIRE
PROJECT TO THE LOWEST TOTAL BID PRICE.
2. CONSTRUCTION OF THIS PROJECT IS ANTICIPATED TO START
IN SEPTEMBER OF 2026.
3. PORTIONS OF THE OVERALL PROJECT AND/OR INDIVIDUAL
BID ITEMS MAY BE ADDED, REMOVED, AND/OR REDUCED BY
THE OWNER (AS NEEDED) TO MATCH THE PROPOSED BUDGET
FOR THIS PROJECT.
4. NO PARTIAL BIDS WILL BE ACCEPTED FOR THIS PROJECT,
ONLY COMPLETE AND TOTAL BIDS WILL BE CONSIDERED.
5. ALL BID ITEMS AND UNIT PRICES MUST BE COMPLETED TO
BE CONSIDERED A COMPLETE AND TOTAL BID.
KEYSTONE CONSULTING ENGINEERS, INC.
KEYSTONE CONSULTING ENGINEERS, INC.
0 10 20 40 80
( IN FEET )
1 inch = 20 ft.
GRAPHIC SCALE
DOTTERS CORNER ROAD (S) CULVERT
ONE CALL SERIAL NUMBERS
FINAL DESIGN:
OF EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
1 - 800 - 242 - 1776
PENNSYLVANIA ACT 38 (1991) REQUIRES NOTIFICATION
O T
S
P E
N
P
A
C L L B
Y S
N A
N
VL
A I
O EN
D
ERE F O
U
YO
C N
I G
E
LAC L
ST
SY
M, I
SURFACE ANYWHERE IN THE COMMONWEALTH.
PENCOR SERVICES/BLUE RIDGE COMMUNICATIONS GENERAL # (610) 826-2555
ALUMINUM BOX CULVERT
11'8" X 5'9" X 40.5 LF (SEE DETAIL)
LINE LEGEND
K E
Y S
T O
N E
C O
N S
U L
T I
N G
E N
G I
N E
E R
S
I N
C
E n g i n e e r i n g f i r m o f c h o i c e s i n c e
RE
VI
SI
O
N S
BY
D
AT
E
PO
LK
T O
W N
SH
IP
M O
N
RO
E
CO
UN
TY
, P
EN
N
SY
LV
AN
IA
CO
N
ST
RU
CT
IO
N A
N D
E A
SE
M
EN
T
PL
A
N
D O
TT
ER
S
CO
RN
ER
R O
A D
SO
U
TH
ER
N
E N
D
CU
LV
ER
T
RE
PL
A
CE
M
EN
T
D
ES
IG
N
ED
B
Y:
D
RA
W N
B Y:
CH
EC
KE
D
B Y:
D
AT
E:
SC
AL
E:
JO
B N
UM
BE
R:
SH
EE
T:
KC
E
LL
H
ES
S
/1
3/
AS
S
H O
W N
PO
LK
-2 4-
O
F
R
O D
E N
B A
C H
L A
N E
B
R O
D H
E A
D S
V I
L L
E
P A
- 6
N N
PROJECT PURPOSE:
THE PURPOSE OF THIS PROJECTS IS TO REPLACE AN EXISTING 4' ROUND CMP
CULVERT WITH A NEW 11'-8"-"X 5'9" ALUMINUM BOX CULVERT. THE EXISTING
CULVERT IS DETERIORATING AND UNDER SIZED. THIS IS CAUSING FLOODING
ISSUES . THE NEW CULVERT WILL PROVIDE ADDITIONAL FLOW CAPACITY,
ADEQUATE COVER OVER THE CULVERT AND HAVE AN ASSOCIATED RESTORED
STREAM BED TO FACILITY AQUATIC ORGANISM PASSAGE AND STREAM BED
CONTINUITY. ASSOCIATED WITH THIS PLAN IS A CHAPTER 105 WATER
OBSTRUCTION AND ENCROACHMENT GENERAL PERMIT REGISTRATION,
SPECIFICALLY A GP#11, FOR THE REPLACEMENT OF AN EXISTING WATER
OBSTRUCTION.
The soil that will be disturbed by this project is:
· KaB - Kedron Silt Loam
General Soil Characteristics:
Soils: Erosion Potential Frost Action Potential Topsoil Road Fill KaB poorly drained/high runoff High Unsuitable Variable
CHAPTER 93 STREAM CLASSIFICATION
All storm water run-off generated from this site is currently (and will continue to be) directed to Dotters Creek. This section has a Chapter 93 Receiving Watercourse designation of Exceptional Value - Cold Water Fisheries (EV-CWF) and is classified as supporting Migratory Fishes (MF).
Wetland Statement:
Steven Hawk of Keystone Consulting Engineers, Inc. has determined, through field verification, State and Federally Regulated Wetlands exist within the project site's limit of disturbance. This inventory for wetland conditions was conducted according to Federal and State guidelines as described in the Regional Supplement to the Corps of Engineers Wetland Delineation Manual: Northcentral and Northeast Region, Version 2.0 as agreed to process for identifying and delineating wetlands in Pennsylvania. Wetland are shown in plan view.
PAVEMENT MILLING NOTES:
1. PAVEMENT MILLING SHALL OCCUR AT THE LIMIT OF THE PAVEMENT
RESTORATION WORK.
PAVEMENT MILLING TRANSITION DETAIL
EXISTING PAVEMENT
TO BE REMOVED
EXISTING PAVEMENT / LIMIT OF
PROPOSED PAVEMENT RESTORATION
PROPOSED
PAVEMENT
MILLING AREA
5' MIN.
EXISTING
PAVEMENT
TO REMAIN
SEAL ALL PAVEMENT JOINTS AND UTILITIES
WITH A PENN DOT APPROVED PAVEMENT
JOINT SEALER (INCIDENTAL TO OVERLAY
PROJECT COSTS)
BITUMINOUS TACK COAT TO BE
PLACED ON ALL EXISTING PAVEMENT
PRIOR TO OVERLAY (INCIDENTAL TO
OVERLAY PROJECT COSTS)
LIMIT OF PAVEMENT
REMOVAL AREA
NOT TO SCALE
SUPERPAVE ASPHALT MIXTURE DESIGN, HMA
WEARING COURSE, PG 64 - 22, 0.3 TO 3.0 MILLION
ESAL'S. 9.5 MM MIX. 1-1/2 IN. DEPTH
1-1/2" (TYP.)
PROPOSED PAVEMENT RESTORATION DETAIL
PROPOSED ROADWAY
& DRIVEWAY
PAVEMENT
RESTORATION AREA
(SEE PLAN FOR
LOCATIONS)
SAW CUT AND REMOVE
EXISTING PAVEMENT,
STONE BASE, AND
SUBGRADE (AS NEEDED) TO
COMPLETE THE PROPOSED
IMPROVEMENTS
PROPOSED 6" PENNDOT 2A STONE BASE
SEAL ALL PAVE
JOINTS AND
UTILITIES WITH A
PENN DOT APPROVED
PAVEMENT JOINT
SEALER
EXISTING CRUSHEDSTONE BASE TOREMAIN
EXISTINGPAVEMENT TOREMAIN
EXISTING PAVEMENT TO REMAIN
1/4" PER FT. (TYP)
EXISTING SUBGRADE TO
REMAIN UNDISTURBED
EXISTING CRUSHEDSTONE BASE TOREMAIN
EXISTINGPAVEMENT TOREMAIN
EXISTING PAVEMENT TO REMAIN
BITUMINOUS TACK COAT TO BE
PLACED ON ALL EXISTING PAVEMENT
PRIOR TO WEARING COURSE
2 FT. MIN.
PAVEMENT
MILLING
NOT TO SCALE
EXISTING PAVED
AREA TO REMAIN
2 FT. MIN.
PAVEMENT
MILLING
EXISTING PAVED
AREA TO REMAIN
PAVEMENT RESTORATION NOTES:
1) ALL PAVEMENT RESTORATION SHALL CONSIST OF SUPERPAVE ASPHALT MATERIAL
2) PAVEMENT JOINT SEALER SHALL BE PLACED AT ALL PAVEMENT JOINTS, AT ALL
STRUCTURES, AND AROUND ALL EXISTING UTILITIES
3) A BITUMINOUS TACK COAT SHALL BE PLACED ON ALL EXISTING PAVEMENT PRIOR TO
THE PROPOSED PAVEMENT RESTORATION WORK
4) PAVEMENT MILLING SHALL OCCUR AT THE LIMITS OF WORK AND AS SHOWN ON THE
PLANS TO EVENLY TIE THE PROPOSED PAVEMENT INTO THE EXISTING PAVED AREAS
SUPERPAVE ASPHALT MIXTURE DESIGN, HMA
WEARING COURSE, PG 64 - 22, 0.3 TO 3.0 MILLION
ESAL'S. 9.5 MM MIX. 1-1/2 IN. DEPTH
LAWN & DRIVEWAY RESTORATION NOTES:
1) ALL EXISTING GRASS / LAWN RESTORATION AREAS SHALL INCLUDE 4" TOPSOIL
PROPERLY SEEDED WITH CONTRACTORS MIX AND MULCHED.
2) ALL EXISTING CRUSHED STONE DRIVEWAY RESTORATION AREAS SHALL
CONSIST OF 6" PENN DOT 2A STONE BASE SLOPED TO MATCH EXISTING
CONDITIONS.
SUPERPAVE ASPHALT MIXTURE DESIGN, HMA
BASE COURSE, PG 64 - 22, 0.3 TO 3.0 MILLION
ESAL'S 25.0 MM MIX 4-1/2 IN DEPTH
K E
Y S
T O
N E
C O
N S
U L
T I
N G
E N
G I
N E
E R
S
I N
C
E n g i n e e r i n g f i r m o f c h o i c e s i n c e
RE
VI
SI
O
N S
BY
D
AT
E
PO
LK
T O
W N
SH
IP
M O
N
RO
E
CO
UN
TY
, P
EN
N
SY
LV
AN
IA
D
ET
A
IL
S H
EE
T
D O
TT
ER
S
CO
RN
ER
R O
A D
SO
U
TH
ER
N
E N
D
CU
LV
ER
T
RE
PL
A
CE
M
EN
T
D
ES
IG
N
ED
B
Y:
D
RA
W N
B Y:
CH
EC
KE
D
B Y:
D
AT
E:
SC
AL
E:
JO
B N
UM
BE
R:
SH
EE
T:
KC
E
LL
H
ES
S
/1
3/
AS
S
H O
W N
PO
LK
-2 4-
O
F
R
O D
E N
B A
C H
L A
N E
B
R O
D H
E A
D S
V I
L L
E
P A
- 6
| POLK-24-024 CONSTRUCTION-(01) Cover |
| Sheets and Views |
| (01) Cover |
| POLK-24-024 CONSTRUCTION-(02) Plan |
| Sheets and Views |
| (02) Construction |
| POLK-24-024 CONSTRUCTION-(03) Details |
| Sheets and Views |
| (03) Details |
File details come from the government source that posted it. Updated .