This is a photo documentation file for the Texas Department of Criminal Justice (TDCJ) Memorial Unit electrical replacement project located in Rosharon, Texas. The document consists of 83 photographs with accompanying reference sheets that visually document the existing electrical infrastructure systems, equipment locations, and spatial configurations throughout the facility. The photographs provide detailed visual evidence of current conditions including existing electrical panels, distribution systems, substations, cable trays, mechanical rooms, boiler rooms, generator systems, and various electrical equipment locations that will be affected by the proposed electrical replacement project. The documentation serves as Exhibit 7 to the project specifications (696-FD-26-P036) and cross-references multiple electrical drawing sheets (EP-203, EP-207, EP-301, EP-108, EP-103, EP-104, EP-206) to establish baseline conditions and identify areas requiring modification, relocation, or replacement.
The photo documentation identifies specific equipment requiring relocation or replacement, including unit substations, motor control centers, generator distribution systems, cable trays, panels, transfer switches, and associated infrastructure. Key facility areas documented include the boiler room mezzanine, rooftop mechanical room, future electrical room location, spline corridor access points, laundry facilities, kitchen panels, and the main transformer installation. The photographs capture existing conditions of the 5KV distribution switchgear, standby power systems, generator louvers, and manual transfer switches that will be impacted during Phase One of the electrical system modernization. The visual record establishes baseline documentation for the existing 4160V radial electrical power distribution system that TDCJ intends to replace as part of the comprehensive electrical infrastructure upgrade project.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ST-F
REFER TO SHEET EP-203
1.
EXHIBIT 7
696-FD-26-P036
CORRIDOR TO SPLINE
EP-107
2.
ST-D
REFER TO EP-207
MCC1 MCC2
CONDENSATE
EXPANSION
CABLE TRAY
3.
PG-1 PG-2
REFER TO SHEET EP-301
4.
KP3B
KP-2
REFER TO SHEET EP-108
5.
RECESSED PANEL
IN INVESTIGATION
ROOM
REFER TO SHEET EP-103
6.
TYPICAL GFI PANEL LOCATED IN
PICKETS
7.
GB GB2
REFER TO SHEET EP-301
8.
CRANE AREA
DOORS AT BACK
OF ROOF
MECHANICAL
ROOM
9.
ROOF TOP MECHANICAL ROOM
REFER TO SHEET EP-108
10.
EXISTING UNIT SUBSTATION K
11.
REFER TO EP-108
TOOL BOX TO BE
RELOACTED
RESTROOM TO BE
RELOACTED
RESTROOM TO REMAIN IN
PLACE
ROOF TOP MECHANICAL ROOM
12.
MCCM
MCCK
ATS
13.
B
IO
LE
R
R O
O M
M
E Z
Z A
N
IN
E F
U T
U R
E S
T A
N D
B Y
P O
W E
R D
IS
T
R
IB
U T
IO
N
L O
C A
T
IO
N
T O
O
LS
, M A
T E
R
IA
L, R
A C
K S
, B E
N C
H E
S T
O B
E R
E
LO
C A
T E
D
14.
PANEL KM
REFER TO SHEET EP-104
15.
B O
IL
E
R R
O O
M V
IE
W
F R
O M
N O
R T
H S
ID
E
O F
T H
E M
E Z
Z A
N
IN
E
16.
BOILER ROOM MEZZANINE
TOOLS AND BENCH TO BE
RELOCATED
17.
F U
T U
R E
E
LE
C T
R
IC
A L
R O
O M
LO
C A
T
IO
N O
F S
S -E
, S S
-F , S
S -A
S T
E E
L P
LA
T
F O
R M
T O
B E
R E
M O
V E
D
18.
19.
FUTURE ELECTRICAL ROOM:
LOCATION OF SS-E, SS-F, SS-A
TO BOILER ROOM MEZZANINE
EXISTING 5KV FEED
TO UNIT
SUBSTATIONS TO
BE REMOVED
THIS PHOTO SHOWS
ACCESS TO SPLINE
20.
STAIRS SHOW ACCESS TO SPLINE
COMES FROM BOILER ROOM AND
FUTURE ELECTRICAL ROOM
21.
SPLINE: WEST END
IT RACK TO BE RELOCATED
FUTURE DOUBLE DOOR FOR
EQUIPMENT ACCESS
22.
AVAILABLE FOR EQUIPMENT
ACCESS
23.
TYPICAL PIPING EXPANSION
JOINT
24.
E X
IS
T
IN
G
S T
A N
D B
Y P
O W
E R
IN
B
O
IL
E R
R O
O M
25.
IS
T
IN
G
K
V D
IS
T
R
IB
U T
IO
N
S W
IT
C
H G
E A
R T
O B
E R
E M
O V
E D
(L O
C A
T
IO
N : B
O
IL
E R
R O
O M
26.
S P
LI
N
E : W
E S
T E
N D
27.
IT
R
A C
K T
O B
E R
E
LO
C A
T E
D
EXAMPLE OF EXISTING POWER DISTRIBUTION
28.
S
B S
T A
T
IO
N D
T O
B E
R E
P
LA
C E
D W
IT
H
A D
IS
T
R
IB
U T
IO
N
P A
N E
L F
E D
F R
O M
F U
T U
R E
S U
B S
T A
T
IO
N B
E X
IS
T
IN
G
C A
B
LE
T R
A Y
T O
B E
R E
P
LA
C E
D
S P
LI
N
E : W
E S
T E
N D
29.
N
IT
S
U B
S T
A T
IO
N
S T
B
30.
LAUNDRY MANUAL
TRANSFER SWITCHES
(GENERATOR SIDE FUSES
HAVE BEEN REMOVED).
ONLY NORMAL POWER IS IN
SERVICE
31.
N
IT
S
U B
S T
A T
IO
N
S T
-G
32.
T Y
P
IC
A L
E X
IS
T
IN
G
G E
N E
R A
T O
R D
IS
T
R
IB
U T
IO
N
S Y
S T
E M
(L O
C A
T
IO
N : S
T -G
33.
M C
C
C O
N T
R O
LS
/IN
T E
R F
A C
E
S T
-G
34.
PANEL CA
(FOR REFERENCE)
35.
EMERGENCY POWER
PANEL FOR REFERENCE
36.
P
IC
A L
G E
N E
R A
T O
R P
O W
E R
J- B
O X
F O
R U
N
IT
S U
B S
T A
T
IO
N S
37.
A
C
IL
IT
Y
M A
IN
E
N T
R A
N C
E
38.
LD
B U
IL
D
IN
G
39.
LD
B U
IL
D
IN
G
40.
IS
T
IN
G
F E
E D
T O
T
IR
E S
H O
P
N O
T P
A R
T O
F T
H E
P R
O
JE
C T
41.
P
R
IM
E T
R A
L F
E N
C E
42.
43.
44.
M A
IN
T
R A
N S
F O
R M
E R
(1
0K V
A
45.
46.
W
S T
D O
R M
E A
S T
D O
R M
47.
48.
49.
IR
E S
H O
P
B U
S S
W A
Y C
O N
N E
C T
IO
N
B O
X
M A
IN
P
A N
E L
50.
P
IC
A L
S U
R F
A C
E M
O U
N T
E D
P A
N E
L (L
O C
A T
IO
N
: S W
IN
G
P
IC
K E
T
51.
TYPICAL REASSED
PANEL
52.
K
IT
C H
E N
P A
N E
LS
53.
LAUNDRY PANELS
54.
55.
IN
D
O O
R G
E N
E R
A T
O R
LO
U
V E
R
56.
EXISTING 5KV
SWITCHGEAR (TOP
VIEW)
57.
58.
T U
R E
L O
C A
T
IO
N O
F S
E
LE
C T
O R
S W
IT
C
H E
S
59.
MCC29
ST-G
TS-3
TS-4
REFER TO SHEET EP-206
60.
PANEL KL
61.
PANEL KPI
62.
63.
64.
65.
66.
67.
68.
22" 60"
69.
40"
62"
7'-0"
70.
26"
55"
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
File details come from the government source that posted it. Updated .