2-26.04.21 WCL PVB Request For Proposal Set Drawings.pdf

PDF 3 MB Posted

Attached to
Weber County | Pleasant Valley Branch Roof Improvements
Solicitation number
26-118
Issued by
Weber County, Utah

About this file

This is a Request for Proposal (RFP) set of architectural drawings prepared by Prescott Muir & Associates for the Weber County Library Board of Directors regarding roof improvements at the Pleasant Valley Branch Library located at 5568 S Adams Avenue, Washington Terrace, Utah 84405. The project scope includes a new TPO (thermoplastic polyolefin) roof membrane overlay covering 35,136 square feet and installation of a new roof screen wall system at air handler units and condensing towers. The existing building comprises a main level gross area of 33,480 square feet and a second level gross area of 259 square feet, with total gross building area of 33,739 square feet. Existing parking and building modifications are not required. A mandatory pre-submittal meeting and site tour is scheduled for Tuesday, May 12, 2026, at 10:00 a.m. at the Pleasant Valley Branch location. The architectural drawings include detailed roof plans, exterior elevations, building sections, and specifications for construction details, with design based on the 2021 International Building Code and 2021 International Fire Code standards for a Group A-3 occupancy mixed-use facility.

The project specifications require new Class A fire-resistant roofing materials or colored metal commercial-grade roofing per Washington Terrace Municipal Code requirements, with proposed Kynar-coated metal vertical roof screen panel systems. The roof screen manufacturer is responsible for providing delegated structural design calculations, frame layout, and project-specific attachment details to the existing roof structure, with calculations subject to review by the local Authority Having Jurisdiction and design team. All existing roof-mounted equipment, access doors to air handling units, and roof drain systems are to remain in place with contractor coordination to maintain unobstructed maintenance access. The contractor must verify all field dimensions, existing roof framing locations, and coordinate screen post locations with the roof screen vendor. General notes specify that no fasteners shall penetrate exposed deck areas, and any required deck penetrations must be repaired at no expense to the owner. New continuous heat trace may be required as an alternate item, and detailed specifications are contained in the project manual available through the Bonfire Portal.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C

D

X

AX.X

X

AX.X

A1

AX.X

X

SYMBOLS

XXX

OFFICE

INDICATES FINISHED

GLAZED MASONRY WALL

INDICATES PAGE NO.

INDICATES SECTION NO.

INDICATES DETAIL NO.

INDICATES PAGE NO.

INDICATES GRID NUMBER

INDICATES ROOM NAME

INDICATES ROOM NUMBER

KEYNOTE

REVISIONS

FLOOR TYPE

A

METAL OR METAL STUDS

MASONRY WALL

WOOD WALL

FINISHED WOOD

BLOCKING

CONTINUOUS WOOD

RIGID INSULATION

BATT INSULATION

INDICATES WALL TYPE

INDICATES OBJECT

DOOR NUMBER

INDICATES ELEVATION NO.

INDICATES PAGE NO.

INDICATES ELEVATION

WINDOW NUMBER

INDICATES GLASS TYPE

GYP. BD., CONC. OR

DIMENSION TO FACE OF

DIMENSION TO CENTER

MASONRY

LINE

OBJECT

ELEVATION

CONCRETESTONE

CL

WASHINGTON

HEIGHTS

MEMORIAL

PARK

FRIENDSHIP

PARK

OGDEN

REGIONAL

MEDICAL

CENTER

LION

PARKS

WASHINGTON

TERRACE

OGDEN GOLF AND

COUNTRY CLUB

CLUB

HOUSE

PARK

W A

S H

IN

G

T O

N

T E

R R

A C

E R

D

RHOMER

PARK

W A

S H

IN

G

T B

L V

D

W

ASHINGT BLVD.

A D

A M

S A

V E

P K

W Y

W A

L L A

V E

R

IV

E R

D A

LE

R D

CHIM

ES VIEW

DR.

40TH ST

40TH ST

COUNTRY HILLS DR.

36TH ST36TH ST

W 44TH S

S

W

W RIVERDALE RD.

S W

E B

E R

D R

RIVERDALE

PARK

GOLDEN

SPIKE PARK

S

T

H W

S

W

SOUTH OGDEN

RIVERDALE

CENTRAL PARK

PROJECT SITE

TE

L:

.5

.9

S

LT

LA

K

C

IT

Y

U

TA

H

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

F

S

E R

V

IC

D

S

H A

L L

R

E M

IN

P

R O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

U T

H O

R

IZ

E D

I N

W R

IT

IN

G

Y

E S

C O

T T

M U

IR

A

R C

H

IT

E

W

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

TT

M

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

T

IT

L E

S H

E E

T

T

WEBER COUNTY LIBRARY

PLEASANT VALLEY BRANCH - ROOF

IMPROVEMENTS

5568 S ADAMS AVE.

WASHINGTON TERRACE, UT

04.21.26

RFP, REQUEST FOR PROPOSAL SET

N M

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

C H

R

O O

F I

M P

R O

V E

M E

N T

S

A1.3 ROOF PLAN

A2.1 EXTERIOR ELEVATIONS

A3.1 BUILDING SECTIONS

A5.1 DETAILS

A5.2 DETAILS

T1 TITLE SHEET

INDEX OF DRAWINGS

ABBREVIATIONS

F.O. FACE OF

M.R.

P.C.J.

SIM.

R.D.

N.I.C.

SIMILAR

ROOF DRAIN

PLASTER CONSTRUCTION

JOINT

NOT IN CONTRACT

MOISTURE RESISTANTANCHOR BOLT

CONTROL JOINT

CATCH BASIN

ADJUSTABLE

CONCRETE

A.B.

C.B.

ADJ.

C.J.

A.C.

CONC.

ASPHALTIC CONCRETE

T.W.

S. STL.

T.O.C.

U.N.O.

V.C.

TYP.

T.O.W.

T.O.S.

UNLESS NOTED OTHERWISE

VINYL COMPOSITION

TYPICAL

TOP OF WALL

TOP OF STEEL

TOP OF WALK

STAINLESS STEEL

TOP OF CONCRETE

WITHW/

EXPANSION JOINT

DIFFUSER

EQUAL

FINISH FLOOR

FLOOR DRAIN

EXTERIOR

EXISTING

ELEVATION

DIF.

E.J.

EQ.

F.F.

F.D.

EXT.

EL.

EXIST.

INTERIOR

GYPSUM BOARD

FIRE TREATEDF.T.

INT.

GYP.BD.

F.S.R. FLEXIBLE SHEET ROOFING

CONTINUOUSCONT.

STEELSTL.

NO. SHEET TITLE

V.I.F. VERIFY IN FIELD

PROJECT SUMMARY

PRESCOTT MUIR & ASSOCIATES

171 WEST PIERPONT AVENUE

SALT LAKE CITY, UT 84101

801.521.9111 FAX 801.521.9158

WEBER COUNTY LIBRARY

2464 JEFFERSON AVENUE

OGDEN, UT, 84401

801.337.2618 FAX 801.337.2615

STRUCTURAL ENGINEER

ARCHITECT

OWNER PROJECT SCOPE OF WORK:

1. NEW ROOF MEMBRANE OVERLAY 35,136 S.F.

2. NEW ROOF SCREEN WALL AT AIR HANDLER UNITS &

CONDENSING TOWER

BUILDING AREA: EXISTING TO REMAIN, NO MODIFICATIONS

MAIN LEVEL GROSS AREA: 33,480 S.F.

SECOND LEVEL GROSS AREA: 259 S.F.

TOTAL GROSS BUILDING AREA: 33,739 S.F.

PARKING: EXISTING TO REMAIN, NO MODIFICATIONS

ARCHITECTURAL

T.O. TOP OF

BOTTOM OFB.O.

STRUCTURAL

NOTE:

THE CONTRACT DOCUMENTS ARE BASED ON PRELIMINARY REACTION STRUCTURAL LOADS

PROVIDED BY THE BASIS OF DESIGN SCREEN WALL VENDOR. ONCE THE PROJECT IS BID AND

AWARDED TO A SPECIFIC SCREEN WALL VENDOR, THE VENDOR WILL PROVIDE FINAL COMPLETE

CALCULATIONS AND LAYOUT FOR DOCUMENTATION AND REVIEW BY THE LOCAL AHJ & DESIGN

TEAM.

DEFERRED SUBMITTALS DESIGN AND CODE CRITERIA

MEMO, DATED 04.10.2026

ARW STRUCTURAL ENGINEERS

1594 PARK CIRCLE

OGDEN, UT, 84404

801.782.6008 FAX 801.782.4656

APPLICABLE CODES:

INTERNATIONAL EXISTING BUILDING CODE 2021

INTERNATIONAL BUILDING CODE 2021

INTERNATIONAL FIRE CODE 2021

A. OCCUPANCY AND GROUP: A-3

MIXED OCCUPANCY YES

B. SEISMIC & WIND CRITERIA: RE: STRUCTURAL MEMO

C. TYPE OF CONSTRUCTION: IIB

D. EXISTING ROOF ASSEMBLY FIRE RATING: 0HR

E. FIRE SPRINKLERS: YES

ZONING:

NEIGHBORHOOD COMMERCIAL C-1

WASHINGTON TERRACE MUNICIPAL CODE:

17.29.70: ARCHITECTURAL DESIGN STANDARDS

REQUIRED:

NEW BUILDING OR REMODELING OF AN EXISTING

BUILDING SHALL USE CLASS A TYPE FIRE RESISTANT

ROOFING MATERIAL OR A COLORED METAL

COMMERCIAL GRADE ROOFING MATERIAL; THE MILL

FINISH (NONCOLORED) ALUMINUM METAL ROOFING

MATERIAL UNLESS SPECIFICALLY REQUESTED BY

THE APPLICANT AND APPROVED BY THE PLANNING

COMMISSION/CITY COUNCIL SHALL NOT BE USED.

PROPOSED:

NEW TPO ROOF MEMBRANE OVERLAY AND NEW KYNAR

COATED METAL VERTICAL ROOF SCREEN PANEL SYSTEM,

RE: EXTERIOR ELEVATIONS.

1. ROOF SCREEN MANUFACTURER DELEGATED STRUCTURAL DESIGN & CALCULATIONS:

THE ROOF SCREEN VENDOR SHALL PROVIDE FRAME LAYOUT, PROJECT-SPECIFIC DETAILS OF

ATTACHMENT TO THE EXISTING ROOF STRUCTURE, AND COMPLETE STRUCTURAL

CALCULATIONS.

NOT TO SCALEVICINITY MAP

17'-4" 13'-4" 19'-8" 5" 30'-11 1/4" 17'-8 3/4" 21'-4" 5'-4" 25'-10 1/2" 26'-6" 14'-11 1/2" 11'-9" 27'-3"

8.6

8.6

5.8

5.8

2.9

2.9

AA

BB

CC

DD

EE

E.3E.3

A.1A.1

B.9B.9

5' -2

9'

-1 0"

7' -6

'-6

8' -0

'-8

'-2

/4

'-2

'-1

3/

4"

1/ 4"

'-8

'-3

/4

1' -8

FF

1.6

1.6

12 32

GG

G.6G.6

HH

H.7H.7

JJ

MECHANICAL ROOF DECK BEARING

116'-4 1/2"

LINE OF STEP

IN ROOF

LINE OF STEP

IN ROOF

A2.1

A2.1

A3.1

A3.1

HIGH DECK BEARING

121'-6 1/8"

T.O. FLASHING

122'-11 1/4"

T.O. FLASHING

130'-3 1/4"

SLOPE 1/4" : 1'-0" MIN.

LOW DECK BEARING

120'-7 1/4"

6 6

S L O

P E

/4

M

IN

HIGH DECK BEARING

128'-4 1/2"

LOW DECK BEARING

127'-4 1/8"

T.O. FLASHING

130'-3 1/4"

T.O. FLASHING

127'-9 1/2"

DECK BEARING

127'-1"

DECK BEARING @ GRID A.1

118'-1"

DECK BEARING @ GRID B

114'-8"

DECK BEARING @ COLUMN

117'-8"

STRUCTURAL VALLEY

6 6

2' -0

2'-0"2'-0"

2' -0

13 TYP.

13 TYP.

13 TYP.

13 TYP.

13 TYP.

13 TYP.

A3.1

A3.1

A5.1

13 TYP. 13 TYP.

'-0

" V .I.

F.

VALLEY

RIDGE

S L O

P E

S L O

P E

S L O

P E

TYP.

DECK BEARING @ GRID E.3

114'-8"

2' -1

/4

" V .I.

F.

169'-10"

171621

S L O

P E

A5.1

SIM

A5.1

SIM

A5.2

A5.1

LOW

A5.1

LOW

A5.1

SIM

A5.1

A5.1

A5.1

A5.1

23227

A5.2

A5.2

A5.2

A5.1

A5.1

A5.1

A5.1

A5.2

A5.1

A5.1

LOW

A5.1

MASONRY

SIM.

A5.1

SIM.

A5.1

SIM.

A5.1

SIM.

A5.1

LOW

A5.2

A5.1

A5.1

A5.1

A5.1

A5.1

LADDER

V .I.

F.

5' -4

" F R

A M

E S

P A

N

5' -4

" P O

S T

S P

A N

11 11

7 66

13 TYP.

AHU AHU

13 TYP.

TYP.

13 TYP.

TYP.

4 TYP. 20 TYP.

V.I.F.

6'-0" FRAME SPAN

TYP.

TYP.

4 TYP. 20

TYP.

V.I.F.

5'-8 3/4" POST SPAN

A5.2

A5.2

2' -0

A5.2

'-7

/4

A5.2

1' -8

SIM

NEW FULLY ADHERED

TPO ROOF MEMBRANE

OVERLAY

EXISTING ROOF

MEMBRANE, CLEAN,

CUT IN A 10'-0" X 10'-0"

GRID, AND PREPARE

PER MANUFACTURER

WARRANTY

REQUIREMENTS

EXISTING ROOF

INSULATION TO REMAIN

TE

L:

.5

.9

Y

U

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

S

E R

V

D

S

H A

L L

R

E M

O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

T

H O

R

IZ

E D

I N

W R

IT

IN

G

E S

C O

T T

M U

IR

A

R C

H

IT

E

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

R O

O F

P

LA

N R

O O

F P

LA

N

R O

O F

P

LA

N R

O O

F P

LA

N

A .3

N M

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

L E

A S

A N

T V

A L

L E

Y B

R A

N

E A

S A

N T

V A

L L

E Y

B R

A N

E

A S

A N

T V

A L

L E

Y B

R A

N C

H

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

1/8" = 1'-0"

ROOF PLAN

N

1 EXISTING COOLING TOWER TO REMAIN

2 EXISTING AIR HANDLING UNIT TO REMAIN

3 EXISTING ROOF HATCH TO REMAIN, EXTEND

NEW ROOF MEMBRANE OVERLAY UNDER ROOF

HATCH FLASHING

4 NEW TPO WALKWAY PADS

5 NEW MECHANICAL ROOF SCREEN, RE:

ELEVATIONS & DETAILS

6 EXISTING TAPERED RIGID INSULATION CRICKET

7 EXISTING PRIMARY ROOF DRAIN TO REMAIN

8 REMOVE EXISTING CAP, INSTALL NEW

MEMBRANE, AND REPLACE EXISTING CAP

OVER MEMBRANE

9 EXISTING SCUPPER TO REMAIN

10 EXISTING ROOFTOP MECHANICAL DUCTS TO

REMAIN, SHOWN DASHED

11 ACCESS GATE IN MECHANICAL ROOF SCREEN

12 NEW FULLY ADHERED ROOF MEMBRANE

OVERLAY, RE: ROOF OVERLAY TYPE 1,

COORDINATE EXACT LOCATION WITH AHU

ACCESS AND OWNER APPROVAL

13 NEW CONTINUOUS STRIP FLASHING

14 LINE OF NEW ROOF MEMBRANE OVERLAY

BELOW ROCK BALLAST

15 NEW PAINTED STEEL LADDER, RE: DETAIL

ROOF PLAN KEYED NOTES

ROOF OVERLAY TYPES

ROOF PLAN GENERAL NOTES

1. AT LOCATIONS WHERE DECK IS SCHEDULED TO BE

EXPOSED, NO FASTNERS SHALL BE ALLOWED TO

PENETRATE DECK. ANY DECK PENETRATION WILL BE

REQUIRED TO BE REPAIRED AT NO EXPENSE TO THE

OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE

TO REVIEW THE CEILING PLAN FOR LOCATIONS OF

FINISH EXPOSED DECK AND VERIFY ANY

DISCREPANCIES WITH THE ARCHITECT PRIOR TO

COMMENCEMENT OF WORK.

2. REFER TO DETAIL REGARDING TYPICAL

FLASHING DETAIL AT ROOF PENETRATIONS.

3. REMOVE ALL EXISTING TPO WALKWAY PADS, CLEAN

AND PREP EXISTING ROOF MEMBRANE TO RECEIVE

NEW ROOF MEMBRANE OVERLAY PER

MANUFACTURER'S WARRANTY REQUIREMENTS.

4. CONTRACTOR TO VERIFY LOCATIONS OF ALL

EXISTING ROOF MOUNTED EQUIPMENT AND ACCESS

DOORS TO AHU AND COORDINATE W/ ROOF SCREEN

VENDOR TO PROVIDE UNOBSTRUCTED ACCESS FOR

ALL REQUIRED MAINTENANCE.

5. VERIFY IN FIELD EXACT ROOF FRAMING LOCATIONS

AND COORDINATE WITH SCREEN VENDOR FOR NEW

SCREEN POST LOCATIONS.

6. ROOF SCREEN SYSTEM, INCLUDING FRAME AND POST

LOCATIONS ARE SHOWN BASED ON PRELIMINARY

LOAD CALCULATIONS AND ARE SUBJECT TO CHANGE

BASED ON FINAL SCREEN WALL DELEGATED DESIGN.

7. GRIDLINES AND GRID DIMENSIONS

SHOWN BASED ON RECORD DRAWINGS.CONTRACTOR

TO VERIFY ALL DIMENSIONS IN FIELD.

16 EXISTING VENT

17 EXISTING EXHAUST FAN

18 FACE OF BUILDING BELOW SHOWN DASHED

19 REMOVE AND REPLACE EXISTING TPO

WALKWAY PADS

20 NEW ROOF SCREEN FRAME SHOWN DASHED,

RE: ROOFSCREEN MFR.

21 REMOVE EXISTING METAL FLASHING AND

SEALANT JOINT, EXTEND NEW ROOF

MEMBRANE UP MASONRY AND REINSTALL

FLASHING AND SEALANT JOINT

22 EXISTING SCUPPER TO REMAIN, EXTEND

OVERLAY THROUGH OPENING, TIE INTO

EXISTING FLASHING

23 REMOVE AND REPLACE SPLASH BLOCK ONTO

NEW OVERLAY

24 NEW ROOF SCREEN POST, RE: DETAIL

1.

25 RELOCATE / ADJUST PLACEMENT OF EXISTING

ROOF VENT PIPING OR FLUE TO

ACCOMMODATE NEW ROOF SCREEN FRAME.

26 NEW CONTINUOUS HEAT TRACE SHOWN

HATCHED SURFACE MOUNTED TO T.O. SHEET

METAL KNIFE EDGE, HOLD BACK FROM EDGE

MIN. 1/2", CONCEAL FROM VIEW BELOW, REFER

TO ALTERNATES IN PROJECT MANUAL

FINISH FLOOR

100'-0"

1091 2 3 4 5 6 7 8.685.82.91.6

T.O. MASONRY (HIGH)

130'-0"

T.O. CONTROL ROOM FLASHING

/ T.O. ROOF SCREEN

127'-9 1/2"

T.O. CONTROL ROOM FLASHING

/ T.O. ROOF SCREEN

127'-9 1/2"

DECK BEARING @ GRID G

118'-0"

DECK BEARING @ GRID E.3, B

114'-8"

5 61

T.O COOLING TOWER

133'-8 5/8"

ROOF SCREEN BEYOND SHOWN DASHED

A3.1

3 5

TYP. TYP.

10 4 10 7

FINISH FLOOR

100'-0"

ABCDEE.3 A.1B.9FGG.6HH.7J

T.O. MASONRY (HIGH)

130'-0"

T.O. MASONRY (HIGH)

130'-0"

T.O. CONTROL ROOM FLASHING

/ T.O. ROOF SCREEN

127'-9 1/2"

DECK BEARING @ GRID G

118'-0"

DECK BEARING @ GRID E.3, B

114'-8"

T.O COOLING TOWER

133'-8 5/8"

3 7

A3.1

5 89

A5.1

TYP.

1'-0" MIN.

A5.1

A5.1

TE

L:

.5

.9

Y

U

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

S

E R

V

D

S

H A

L L

R

E M

O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

T

H O

R

IZ

E D

I N

W R

IT

IN

G

E S

C O

T T

M U

IR

A

R C

H

IT

E

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

E X

T E

R

IO

R E

LE

V

A T

IO

N

S E

X T

E R

IO

R

E

LE

V A

T

IO

N S

E X

T E

R

IO

R E

LE

V

A T

IO

N

S E

X T

E R

IO

R

E

LE

V A

T

IO

N S

A .1

A H

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

E

A S

A N

T V

A L

L E

Y B

R A

N

E A

S A

N T

V A

L L

E Y

B R

A N

E

A S

A N

T V

A L

L E

Y B

R A

N C

H

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

ELEVATION GENERAL NOTESELEVATION GENERAL NOTESELEVATION GENERAL NOTESELEVATION GENERAL NOTES

- ELEVATION KEYED NOTESELEVATION KEYED NOTESELEVATION KEYED NOTESELEVATION KEYED NOTES

1 NEW MECHANICAL ROOF SCREEN,

SMOOTH FLUSH 1" PROFILE,

KYNAR COATED STEEL TO MATCH

COLOR OF EXIST. SHEET METAL,

12" VERTICAL PANEL, B.O.D.,18"

ACM, 1"+ VERTICAL ALTERNATE

2 NEW ROOF SCREEN BASE

SUPPORTS ATTCHED TO EXISTING

ROOF STRUCTURE, RE: SECTIONS

& DETAILS

3 NEW ROOF SCREEN FRAME

BEYOND SHOWN DASHED,

4 NEW ROOF SCREEN HORIZONTAL

FRAME HAT SECTIONS. SHOWN

DASHED BEYOND.

5 EXISTING AIR HANDLING UNIT TO

REMAIN. SHOWN DASHED BEYOND

6 EXISTING COOLING TOWER TO

REMAIN

7 EXIST. SHEET METAL COPING TO

BE REMOVED AND REINSTALLED.

TO ACCOMODATE NEW ROOF

MEMBRANE, RE: ROOF PLAN &

DETAILS

8 NEW POWDER COATED STEEL

LADDER, RE: DETAIL

SCALE 1/8" = 1'-0"

WEST ELEVATION

SCALE 1/8" = 1'-0"

SOUTH ELEVATION

9 EXIST. MECHANICAL ROOF DUCTS

BEYOND TO REMAIN

10 GATE IN ROOF SCREEN, RE:ROOF

PLAN, COORDINATE EXACT

LOCATION WITH OWNER &

ARCHITECT

A. FIELD VERIFY ALL DIMENSIONS

INCLUDING ELEVATIONS

B. REFER TO PROJECT MANUAL FOR

ALTERNATE ROOF SCREEN OPTIONS.

FINISH FLOOR

100'-0"

A B C D E E.3A.1 B.9 F G G.6 H H.7 J

T.O. CONTROL ROOM FLASHING

/ T.O. ROOF SCREEN

127'-9 1/2"

T.O COOLING TOWER

133'-8 5/8"

STACKS READING STACKS

CIRCULATION LOBBY BOOKSTORE

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY OVER EXISTING MEMBRANE

RE: ROOF PLAN

NEW ROOF SCREEN

EXISTING COOLING TOWER BEYOND

NEW ROOF SCREEN FRAME

A3.1

EXISTING AIR HANDLING UNIT

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY OVER EXISTING MEMBRANE

A5.2

A5.2

V.I.F

V.I.F

A5.2

A5.2POST FLASHING, RE: DETAIL

FINISH FLOOR

100'-0"

1091 2 3 4 5 6 7 8.685.82.91.6

T.O. MASONRY (HIGH)

130'-0" T.O. CONTROL ROOM FLASHING

/ T.O. ROOF SCREEN

127'-9 1/2"

T.O COOLING TOWER

133'-8 5/8"

A3.1

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY OVER EXISTING MEMBRANE

NEW ROOF SCREEN

EXISTING COOLING TOWER BEYOND

NEW ROOF SCREEN FRAME

EXISTING AIR HANDLING UNIT

AUDITORIUM

CONTROL ROOM

PUBLIC MEETING CHILDREN'S ACTIVITY CENTER KITCHEN SNACK BAR CIRCULATION BOILER ROOM GARAGE

NEW POWDER COATED STEEL LADDER

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY OVER EXISTING MEMBRANE

RE: ROOF PLAN

A5.2 10 A5.1

A5.2

A5.2

V.I.F

V.I.F

A5.2

POST FLASHING, RE: DETAIL

TE

L:

.5

.9

Y

U

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

S

E R

V

D

S

H A

L L

R

E M

O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

T

H O

R

IZ

E D

I N

W R

IT

IN

G

E S

C O

T T

M U

IR

A

R C

H

IT

E

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

B U

IL

D

IN

G

S E

C T

IO

N

S B

U

IL

D

IN

G S

E C

T

IO

N S

B U

IL

D

IN

G

S E

C T

IO

N

S B

U

IL

D

IN

G S

E C

T

IO

N S

A .1

A H

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y W

E B

E R

C O

U N

T Y

L

IB

R A

R Y

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T W

A S

H

IN

G T

O N

T E

R R

A C

E

U T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

E

A S

A N

T V

A L

L E

Y B

R A

N

E A

S A

N T

V A

L L

E Y

B R

A N

E

A S

A N

T V

A L

L E

Y B

R A

N C

H

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

R O

O F

I M

P R

O V

E M

E N

T S

SCALE 1/8" = 1'-0"

BUILDING SECTION

SCALE 1/8" = 1'-0"

BUILDING SECTION

1/2" DIAM.

EXPANSION BOLT

EXIST. EXTERIOR CMU

WALL

NEW GROUT SOLID @ EA.

CELL W/ NEW ANCHOR

NEW 3/8" x 4" BENT

PLATE WELDED TO

RAILS @ 48" O.C.

MAX.

3/4" DIAM. RUNGS @ 12" O.C.

2 1/2" X 3/4"

RAIL CONTINUOUS

A

PLAN

B

ELEVATION

A

C L C L

TY

P

1' -0

LINE OF ROOF

MEMBRANE

9"

1/2" DIAM.

EXPANSION BOLT,

ATTACH TO EXIST.

CMU WALL

BEYOND, TYP.

3' -6

A5.1

C L C L

" M

A X

E .Q

. S P

A C

E

NOTES:

• RE: EXTERIOR/ELEVATIONS FOR LADDER, SIZE & PLACEMENT

• LADDER TO COMPLY WITH OSHA STANDARDS

• PROVIDE CONT. POWDER COATING

• FIELD VERIFY DIMENSIONS

2.9 3

" M

IN

2' -6

1'-0"

GROUT SOLID @ EA. CELL WITH NEW ANCHOR

CL

MIN.

7"

EXIST. RIGID

INSULATION

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE:

ROOF PLAN

A5.1

A5.1

SIM

3/8" x 4" BENT PLATE WELDED TO RAILS

@ 48" O.C. MAX.

A5.1

1A

WALK-OFF TPO MATT @

T.O. COPING BETWEEN

LADDER EXTENSIONS

SIM

1/2" DIAM.

EXPANSION BOLT

3/4" DIAM. RUNGS @ 12" O.C.

2 1/2" X 3/4"

RAIL CONTINUOUS

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE:

ROOF PLAN

EXIST. TAPERED FIRE TREATED 2X PLATE

EXIST. MASONRY AS OCCURS, RE: ELEVATIONS

REMOVE AND REINSTALL CONTINUOUS

16 GA. STAINLESS STEEL CLEAT, ANCHOR

TO BLOCKING SCREWS @ 12" O.C.

REMOVE AND REPLACE CONT. SEALANT

EXISTING FULLY ADHERED SINGLE PLY

MEMBRANE ROOFING

1/

4"

1/ 4"

1/2"

T.O MASONRY

REMOVE AND REINSTALL 0.063 CLEAR ANODIZED

ALUMINUM SHEET METAL COPING

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE: ROOF PLAN

REMOVE AND REPLACE GALV. FASTENER

EXIST. FLEXIBLE SHEET

MEMBRANE

EXIST. RIGID

INSULATION

EXIST. FLEXIBLE SHEET

MEMBRANE COUNTER

FLASHING

REMOVE AND REINSTALL

TERMINATION BAR

EXIST. MASONRY

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, EXTEND

UP WALL AND BEHIND REGLET

FLASHING, RE: ROOF PLAN

REMOVE AND REINSTALL EXIST.

SCREW ANCHOR W/ STEEL

BACKED NEOPRENE WASHER

OVER SURFACE MOUNTED

REGLET, PROVIDE NEW SEALANT

REMOVE AND REPLACE CONT.

SEALANT

REMOVE AND INSTALL FLASHING

REMOVE AND REINSTALL 0.063"

CLEAR ANODIZED ALUMINUM

SHEET METAL COPING

EXISTING 0.O63" CLEAR ANODIZED

ALUMINUM SHEET METAL PANELING

EXIST. WEATHER BARRIER

EXIST. 5/8" F.T. PLY WD. SHEATHING

EXIST. METAL STUD FRAMING W/

FULL BATT INSULATION

EXIST. 16 GA CONTINUOUS

STAINLESS STEEL CLEAT

EXIST. GALV. FASTENER

REMOVE AND REINSTALL EXIST. 16 GA

CONTINUOUS STAINLESS STEEL CLEAT

REMOVE AND REPLACE GALV.

FASTENER

EXIST. FLEXIBLE SHEET MEMBRANE

FLASHING

EXIST. 5/8" F.T. PLY WD. SHEATHING

REMOVE AND REPLACE EXIST.

SCREW ANCHOR @ 16" O.C. W/ STEEL

BACKENED NEOPRENE WASHERS TO

MEET FM I90

1/2"

REMOVE AND REPLACE

CONT. SEALANT

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY RUN UP PARAPET WALL AND

UNDER COPING, RE: ROOF PLAN

EXISTING .O63" CLEAR ANODIZED

ALUMINUM STANDING SEAM SHEET METAL

PANELING ON CMU/ 5/8" F.T. PLY WD.

SHEATHING & METAL STUD FRAMING

REMOVE AND REINSTALL

EXISTING .O63" CLEAR ANODIZED

ALUMINUM SHEET METAL COPING

EXIST. FLEXIBLE SHEET MEMBRANE

FLASHING

REMOVE AND REINSTALL

EXISTING 16 GUAGE STAINLESS

STEEL CONTINOUS CLEAT

REMOVE AND REPLACE EXIST.

SCREW ANCHOR @ 16" O.C. W/

STEEL BACKED NEOPRENE

WAHSER TO MEET FM I90

3"3 1/

4"

1"

A5.1

SIM

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RUN UP PARAPET WALL AND

UNDER COPING, RE: ROOF PLAN

REMOVE AND REPLACE EXIST.

SCREW ANCHOR

SIM

REMOVE AND REPLACE SCREW

ANCHOR @ 16" O.C. W/ STEEL BACKED

NEOPRENE WASHERS TO MEET FM I90

EXIST. FULLY ADHERED SINGLE PLY

ROOFING MEMBRANE

EXIST. GROUT SOLID

REMOVE AND REINSTALL EXISTING .063"

CLEAR ANODIZED ALUMINUM SHEET

METAL CAP FLASHING W/ FOLDED FLAT

SEAMS

EXIST. 4" ATLAS BRICK/8"

CMU, RE: ELEVATIONS

T.O. PARAPET

T.O. MASONRY

VARIES

3"

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RUN UP

PARAPET WALL & UNDERCOPING

RE: ROOF PLAN

REMOVE AND REPLACE CONT. SEALANT

JOINT

EXIST. FULLY ADHERED SINGLE PLY

ROOFING MEMBRANE EXTEND OVER TOP OF

PARAPET

REMOVE AND REINSTALL EXISTING 0.063"

CLEAR ANODIZED ALUMINUM SHEET METAL

CAP FLASHING W/ FOLDED FLAT SEAMS

EXIST. 4" ATLAS

BRICK/8" CMU, RE:

ELEVATIONS

T.O. PARAPET

T.O. MASONRY

VARIES

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

REMOVE AND REPLACE

CONT. SEALANT

NEW CONT. MEMBRANE STRIP FLASHING

EXIST. STEEL STRUCTURE

EXIST. CONTINUOUS BENT STEEL PLATE

EXIST. 0.063" PRE-FINISHED PAINTED SHEET

METAL FASCIA, W/ FLAT FOLDED SEAMS ON

VERTICAL SURFACE AND STANDING SEAMS @

10'-0" O.C. ON HORIZONTAL SURFACE AND

CONTINUOUS HOLD DOWN AT EDGE

EXIST. PRE-FINISHED PAINTED SHEET METAL

SOFFIT PANELING

EXIST. 0.063" PRE-MANUFACTURED PAINTED SHEET

METAL PANELING

EXIST. CONTINUOUS BENT STEEL PLATE

EXIST. FLEXIBLE SHEET MEMBRANE

ROOFING ON RIGID INSULATION

ON METAL DECK

EXIST. PAINTED METAL DECKING

COLUMN

5.8

CL

DECK BEARING

VARIES

NEW CONTINUOUS STRIP FLASHING,

REMOVE EXISTING STRIP FLASHING

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

1/2"

5.8

STEEL STRUCTURE

EXIST. FLEXIBLE SHEET

MEMBRANE ON RIGID INSULATION

ON METAL DECK

EXIST. MEMBRANE UP 8"

BEHIND SHEET METAL

PANELING

EXISTING 0.063" CLEAR

ANODIZED ALUM. SHEET

METAL PANELING ON

WEATHER BARRIER ON F.T.

PLY WD. SHEATHING & METAL

STUD FRAMING

EXIST. STEEL STRUCTURE

5.8

T.O. MASONRY

112'-8"

B.O. VALANCE

112'-11 1/4"

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY EXTEND UP

WALL & UNDER SHEET METAL

CLADDING, RE: ROOF PLAN

EXISTING FULLY ADHERED

FLEXIBLE SHEET MEMBRANE OVER

5/8" F.T. PLYWOOD SHEATHING

EXISTING FLEXIBLE SHEET

MEMBRANE OVER RIGID

INSULATION ON METAL DECK

EXIST. STEEL STRUCTURE

EXIST. STEEL BLOCKING

EXIST. PAINTED 5/8" GYP. BD. OVER

5/8" F.T. PLYWOOD SHEATHING ON

16 GA. 8" METAL STUD FRAMING @

16" O.C. W/ FULL BATT INSULATION

EXIST. STEEL STRUCTURE

EXIST. STEEL BLOCKING RE:

STRUCTURAL

EXIST. FLEXIBLE SHEET MEMBRANE

OVER RIGID INSULATION ON METAL

DECK RE: ROOF PLAN, EXTEND

MEMBRANE ROOFING UP GLASS

MATTE FACED GYP. BD. TO BEHIND

MASONRY REGLET

EXIST. 4" CMU VENEER OVER 5/8" GLASS MATTE

FACED GYPSUM SHEATHING

EXIST. STEEL LEDGER ANGLE,

RE: STRUCTURAL

EXIST. CAVITY DRAINAGE MESH

REMOVE AND REINSTALL

EXIST. MASONRY REGLET

OVER NEW FULLY ADHERED

TPO MEMBRANE OVERLAY

EXIST. THROUGH WALL

FLASHING

EXIST. WEEP TUBE

REMOVE AND REINSTALL EXIST. PRE-FINISHED

SHEET METAL COPING OVER F.T. 2x BLOCKING

T.O MASONRY

122'-8"

T.O. FLASHING

122'-11 1/4"

B.O. MASONRY

VARIES, RE: EXTERIOR ELEVATIONS

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RUN

MEMBRANE UP PARAPET WALL &

UNDER COPING RE: ROOF PLAN

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE: ROOF

PLAN

A5.1

SIM

EXIST. PRE-FINISHED PAINTED

SHEET METAL PANELING OVER CMU

BLOCKING

EXIST. PAINTED METAL

DECKING

EXIST. 1" F.T. PLYWOOD SHEATHING

OVER F.T. WOOD BLOCKING

EXIST. 0.063" PRE-FINISHED

PAINTED SHEET METAL

COPING

EXIST. FULLY ADHERED

MEMBRANE ROOFING OVER

RIGID INSULATION ON METAL

DECKING

EXIST. STEEL STRUCTURE

BEYOND

EXIST. STEEL STRUCTURE

DECK BEARING @ GRID 'G'

118' - 0"

G

A5.1

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE: ROOF

PLAN

NEW CONTINUOUS STRIP

FLASHING, REMOVE EXISTING

STRIP FLASHING

SIM

EXIST. SINGLE-PLY ROOF MEMBRANE OVER

RIGID INSULATION ON METAL DECK

EXIST. 0.040" ALUMINUM SHEET

METAL HEMMED OVER STEEL ANGLE

EXIST. CURTAIN WALL WINDOW HEAD

EXIST. STEEL BENT PLATE

EXIST. STEEL STRUCTURE

6"

1/2"

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

NEW CONTINUOUS STRIP FLASHING,

REMOVE EXISTING STRIP FLASHING

EXISTING FLEXIBLE SHEET MEMBRANE

ROOFING ON RIGID INSULATION ON

METAL DECK

EXISTING STEEL

STRUCTURE BEYOND

EXISTING PRE- MANUFACTURED PAINTED

SHEET METAL SOFFIT PANELING

EXISTING 0.063" PRE-FINISHED PAINTED

SHEET METAL FASCIA,

H

DECK BEARING @ GRID 'H'

116'-9"

EXISTING 0.063" PRE-MANUFACTURED

PAINTED SHEET METAL PANELING

EXISTING STEEL BENT PLATE

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, EXTEND UNDER EXISTING

SHEET METAL FLASHING RE: ROOF

PLAN NEW CONTINUOUS STRIP FLASHING; REMOVE

EXISTING STRIP FLASHING

1/2"

TE

L:

.5

.9

Y

U

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

S

E R

V

D

S

H A

L L

R

E M

O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

T

H O

R

IZ

E D

I N

W R

IT

IN

G

E S

C O

T T

M U

IR

A

R C

H

IT

E

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

D E

T A

IL

S

A .1

A H

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

C H

R

O O

F I

M P

R O

V E

M E

N T

S

VARIES

1/2" = 1'-0"

1STEEL LADDER

VERTICAL

1" = 1'-0"

6LADDER TO ROOF DETAIL

VERTICAL

12" = 1'-0"

3COPING DETAIL

VERTICAL

3" = 1'-0"

11TYP. COUNTERFLASHING DETAIL @ MASONRY

VERTICAL

3" = 1'-0"

7TYP. COPING DETAIL @ SHEET METAL

VERTICAL

3" = 1'-0"

5TYP. COPING DETAIL

VERTICAL

3" = 1'-0"

9PARAPET DETAIL

VERTICAL

3" = 1'-0"

10MASONRY COPING DETAIL

VERTICAL

1 1/2" = 1'-0"

13ROOF DETAIL

VERTICAL

1 1/2" = 1'-0"

15ROOF DETAIL

VERTICAL

1" = 1'-0"

8ROOF TRANSITION TO MASONRY

VERTICAL

1 1/2" = 1'-0"

12SLOPING ROOF DETAIL

VERTICAL

3" = 1'-0"

16WINDOW HEAD

VERTICAL

1 1/2" = 1'-0"

14ROOF EDGE DETAIL @ MASONRY

COLUMN

EXISTING ROOF MEMBRANE

EXISTING 0.063" PRE-FINISHED PAINTED SHEET METAL FASCIA,

W/ FLAT FOLDED SEAMS ON VERTICAL SURFACE AND

STANDING SEAMS @ 10'-0" O.C. ON HORIZONTAL SURFACE AND

CONTINUOUS HOLD DOWN AT EDGE

EXISTING STEEL

STRUCTURE

EXISTING PRE-MANUFACTURED PAINTED SHEET METAL SOFFIT

PANELING

DECK BEARING

VARIES, RE: ROOF PLAN

A.1

CL

A

EXISTING ROOF

MEMBRANE OVER

RIGID INSULATION ON

1/4" DENS DECK ON

METAL DECKING, RE:

ROOF PLAN

NEW FULLY ADHERED

TPO MEMBRANE

OVERLAY, RE: ROOF

PLAN

EXISTING STEEL BENT PLATE

NEW CONTINUOUS STRIP FLASHING, REMOVE EXISTING STRIP

FLASHING

SLOPE

1.71 RE: ROOF PLAN

1/2"

EXISTING CANTILEVERED STEEL

STRUCTURE BEYOND

LINE OF FACE OF VESTIBULE

STOREFRONT BELOW

SLOPE 1/4":12"

EXISTING STEEL STRUCTURE

EXISTING 0.063" PRE-FINISHED PAINTED SHEET METAL FASCIA,

W/ FLAT FOLDED SEAMS ON VERTICAL SURFACE AND

STANDING SEAMS @ 10'-0" O.C. ON HORIZONTAL

SURFACE AND CONTINUOUS HOLD DOWN AT EDGE

SLOPE 1/4":12"

DECK BEARING / B.O. STEEL PLATE

116'-7"

EXISTING STEEL BENT PLATE

EXISTING STEEL STRUCTURE

EXISTING ROOF MEMBRANE ON TAPERED RIGID

INSULATION ON METAL DECK, RE: ROOF PLAN

LINE OF METAL FLASHING BEYOND

NEW FULLY ADHERED TPO MEMBRANE OVERLAY,

RE: ROOF PLAN

NEW CONTINUOUS STRIP FLASHING, REMOVE EXISTING STRIP

FLASHING

1/2"

EXISTING STEEL

STRUCTURE BEYOND

EXISTING MEMBRANE

ROOFING OVER RIGID

INSULATION ON METAL

DECK, EXTEND OVER

CANT STRIP AND

PERIMETER BLOCKING

EXISTING 0.063" PRE-FINISHED PAINTED SHEET

METAL FASCIA, W/ FLAT FOLDED SEAMS ON

VERTICAL SURFACE AND STANDING SEAMS @ 10'-0"

O.C. ON HORIZONTAL SURFACE AND CONTINUOUS

HOLD DOWN AT EDGE

EXISTING PRE-MANUFACTURED PAINTED SHEET

METAL SOFFIT PANELING OVER WEATHER BARRIER

ON 5/8" F.T. PLYWOOD SHEATHING ON 3 5/8" 20 GA.

STUD FRAMING @ 16" O.C.

EXISTING MEMBRANE ROOFING OVER 1/2" F.T.

PLYWOOD SHEATHING

EXISTING STEEL BENT PLATE

EXISTING STEEL STRUCTURE

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE:

ROOF PLAN

NEW FULLY ADHERED TPO MEMBRANE OVERLAY,

RE: ROOF PLAN

EXISTING EXTERIOR MASONRY,

RE: EXTERIOR ELEVATIONS

1/2"

NEW CONTINUOUS STRIP FLASHING, REMOVE

EXISTING STRIP FLASHING

SLOPE 1/2"

EXISTING MEMBRANE ROOFING

EXISTING PRE-FINISHED PAINTED

SHEET METAL FLASHING, W/

CONTINUOUS 16 GA. STAINLESS STEEL

HOLD DOWN CLEAT FASTENED TO 5/8"

F.T. PLYWOOD, TYP.

EXISTING MEMBRANE ROOFING OVER

RIGID INSULATION ON 4" LIGHTWEIGHT

CONCRETE AND METAL DECK

EXISTING FULLY ADHERED SINGLE-PLY

ROOFING MEMBRANE ON 5/8" FIRE

TREATED PLYWOOD SHEATHING FULLY

ADHERED TO STEEL BENT, EXTEND

PLYWOOD AND MEMBRANE OVER TOP

OF BENT PLATE

T.O. CORNICE

130'-8"

T.O. MASONRY

130'-0"

DECK BEARING @ MASONRY

127'-4 1/8"

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

2'-0"

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, EXTEND UP PARAPET &

OVER BENT PLATE TO COPING RE:

ROOF PLAN

RELOCATE EXISTING ROCK BALLAST

FROM ROOF PERIMETER AND

REINSTALL AFTER TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

NEW FULLY ADHERED TPO MEMBRANE

OVERLAY, RE: ROOF PLAN

EXISTING STEEL BENT PLATE

KNIFE EDGE

NEW CONTINUOUS STRIP FLASHING,

REMOVE EXISTING

EXISTING STEEL BENT PLATE

1 3/8" 1/2"

EXISTING BEAM / NEW COLUMN POSTCL

EXISTING STEEL BEAM

EXISTING METAL DECK

ATTACH NEW BASE SUPPORT

TO TOP FLANGE OF EXISTING

STEEL BEAM WITH TEK

SCREWS PER ROOF SCREEN

MFR. CALCULATIONS, TYP.,

RE: ROOF SCREEN

MANUFACTURER

MIN. FLANGE WIDTH

VARIES, V.I.F

V .I.

F.

IN

S

U

LA

TI

O

N D

E P

TH

V

A R

IE

S

BASE SUPPORT EXTENSION

AS REQUIRED, RE: ROOF

SCREEN MANUFACTURER

FLASHING, RE: ROOF

SCREEN MANUFACTURER

EXISTING ROOF MEMBRANE

OVER RIGID INSULATION

NEW FULLY ADHERED TPO ROOF

MEMBRANE OVERLAY, RE: ROOF

PLAN

BASE GASKET, BY ROOF

SCREEN MANUFACTURER

BASE CAP ASSEMBLY, BY

ROOF SCREEN

MANUFACTURER

ROOF SCREEN HORIZONTAL

FRAME

ROOF SCREEN FRAME

BRACKET BEYOND

V E

R

IF

Y W

/ R O

O

FI

N G

R

O O

F S

C R

E E

N V

E N

D O

R

8" M

IN

PAINT TO MATCH ADJACENT

AT ALL EXPOSED TO VIEW

EXIST. PRE-MANUFACTURED PAINTED

SHEET METAL SOFFIT PANELING OVER

WEATHER BARRIER ON 5/8" F.T. PLYWOOD

SHEATHING ON STUD FRAMING

EXIST. STEEL STRUCTURE

EXIST. STEEL BENT PLATE

EXIST. 0.063" PREFINISHED PAINTED

SHEET METAL FASCIA W/ FLAT FOLDED

SEAMS ON VERTICAL SURFACE AND

STANDING SEAMS @ 10" O.C. ON

HORIZONTAL SURFACE AND CONTINUOUS

STAINLESS STEEL HOLD DOWN AT EDGE

EXIST. PREFINISHED PAINTED SHEET

METAL FASCIA RETURN BEYOND

EXIST. FULLY

ADHERED MEMBRANE

ROOFING OVER RIGID

INSULATION

ON METAL DECKING

EXIST. PREFINISHED PAINTED SHEET

METAL PANELING BEYOND

G

NEW FULLY ADHERED

TPO MEMBRANE

OVERLAY, RE: ROOF

PLAN

1/2"

NEW CONTINUOUS STRIP FLASHING,

REMOVE EXISTING STRIP FLASHING

EXIST. STEEL

STRUCTURE

EXIST. MEMBRANE ROOFING

OVER RIGID INSULATION ON

METAL DECK

EXIST. PRE-MANUFACTURED PAINTED

SHEET METAL SOFFIT PANELING OVER

WEATHER BARRIER ON 1" F.T. PLYWOOD

SHEATHING ON 1 5/8" 20 GA. STUD

FRAMING @ 16" O.C.

EXIST. STEEL BENT PLATE

EXIST. 0.063" PRE-FINISHED PAINTED SHEET

METAL FASCIA, W/ FLAT FOLDED SEAMS ON

VERTICAL SURFACE AND STANDING SEAMS @

10'-0" O.C. ON HORIZONTAL SURFACE AND

CONTINUOUS HOLD DOWN AT EDGEEXIST. STEEL STRUCTURE BEYOND

SLOPE

J

1/2"

NEW FULLY ADHERED TPO

MEMBRANE OVERLAY, RE:

ROOF PLAN

NEW CONTINUOUS STRIP

FLASHING, REMOVE

EXISTING STRIP FLASHING

PLUMBING VENT, PIPE

PENETRATION OR GAS PIPING

1' -0

" M

IN

ROOFING SEALANT

DRAWBAND ATTACHMENT WITH FULL

SEALANT BETWEEN PIPE & PRE-FABRICATED

MEMBRANE FLASHING BOOT

SEALED SEAM WITH SEAM CAULK PER

MANUFACTURERS STANDARD DETAIL

PRE-FABRICATED MEMBRANE

FLASHING BOOT

NOTE:

IMPLEMENT MANUFACTURER'S RECOMMENDED PIPE

FLASHING DETAILS WHERE PRE-FABRICATED MEMBRANE

BOOT FLASHING IS NOT COMPATIBLE WITH PIPE DIAMETER

ROOF ASSEMBLY, RE: STRUCTURAL

CONT. "J" TRIM TO MATCH PANEL

NOTE: VERIFY ATTACHMENTS &

CONFIGURATION W/ ROOF SCREEN MFR.

CONT. HORIZONTAL HAT CHANNEL

GIRT BY ROOF SCREEN VENDOR.

CONT. 16 GAUGE SS 4" X4" ANGLE

CONT. "J" TRIM TO MATCH PANEL

SMOOTH, FLUSH PROFILE PANEL,

RE: EXIST. ELEVATIONS

SMOOTH, FLUSH PROFILE PANEL,

RE: EXIST. ELEVATIONS

TE

L:

.5

.9

Y

U

W

E S

T P

IE

R

P O

N T

A V

E

S H

E E

T N

O

D A

TE

D R

A W

N B

Y

P R

O

JE

C T

N O

T H

E S

E D

O C

U M

E N

T S

A R

E I N

S

T R

U M

E N

S

E R

V

D

S

H A

L L

R

E M

O

P E

R T

Y

O

F

T

C

H

IT

E C

T N

O U

S E

O R

R E

U

T

H E

S E

D O

C U

M E

N

A L L B

E P

E R

M

IT

T E

D U

N L E

T

H O

R

IZ

E D

I N

W R

IT

IN

G

E S

C O

T T

M U

IR

A

R C

H

IT

E

H A

P P

R O

P R

IA

T

E C

O M

P

T

IO

N C

O P

Y R

IG

H

P R

E S

C

IR

A S

S O

C

IA

TE

S

A

P R

O

FE

S S

IO

N

A L

C O

R P

O R

A

TI

O N

D E

T A

IL

S

A .2

N M

.2

1.

.0

W E

B E

R C

O U

N T

Y L

IB

R

A R

Y

S A

D A

M S

A V

E

W A

S H

IN

G

T O

N T

E R

R A

C E

U

T

P L

E A

S A

N T

V A

L L

E Y

B R

A N

C H

R

O O

F I

M P

R O

V E

M E

N T

S

VERTICAL

1 1/2" = 1'-0"

1EAST CANOPY @ GLAZING

VERTICAL

1 1/2" = 1'-0"

3CANOPY @ NORTH ENTRY

VERTICAL

1 1/2" = 1'-0"

7SOUTH CANOPY @ MASONRY WALL

VERTICAL

1 1/2" = 1'-0"

10AUDITORIUM CAP DETAIL

VERTICAL

3" = 1'-0"

9ROOF SCREEN POST ATTACHMENT DETAIL

VERTICAL

1 1/2" = 1'-0"

11ROOF DETAIL @ KNIFE EDGE

VERTICAL

1 1/2" = 1'-0"

12ROOF CANOPY DETAIL

VERTICAL

1 1/2" = 1'-0"

13TYPICAL FLASHING @ ROOF PENETRATION

HORIZONTAL

3" = 1'-0"

14ROOF SCREEN CORNER & END DETAIL

Sheets
A1.3 - ROOF PLAN
A2.1 - EXTERIOR ELEVATIONS
A3.1 - BUILDING SECTIONS
A5.1 - DETAILS
A5.2 - DETAILS
T1 - TITLE SHEET

File details come from the government source that posted it. Updated .