This is an Exhibit A equipment inventory list for a lifting equipment inspections, maintenance, and repairs contract issued by the North Texas Municipal Water District (NTMWD). The document provides a comprehensive catalog of lifting equipment assets across multiple NTMWD facilities and partner municipalities, including overhead cranes, monorails, winch derricks, hoists, aerial lifts, and related below-the-hook devices. The inventory encompasses equipment located at wastewater treatment plants, water treatment plants, pump stations, and technical service facilities throughout the NTMWD service area in Texas. Equipment specifications documented include manufacturer details, model numbers, serial numbers, capacity ratings, drive types, motor specifications, and installation locations. The list identifies equipment status as either "In Service" or "Out of Service," along with criticality classifications ranging from Production/Super Critical (20 minutes or less downtime tolerance) to Stand By Maintenance/General Maintenance (24 hours or more tolerance). Contractors responsible for inspections and maintenance are identified by email contact information, including staff members such as Karr, Reber, Owens, and Haworth.
The inventory represents over 400 distinct pieces of lifting equipment with capacity ranges from 0 to 10 tons up to 51 to 100 tons, with the majority falling in the 0 to 10 ton category. Equipment types are distributed across bridge cranes, monorail systems, jib cranes, gantry cranes, winch derricks, small hoists, structural mechanical lifting devices, mobile equipment, slings, shackles, pallet jacks, and specialized lifting apparatus. Original data entry dates and revision dates are documented to track inventory currency, with numerous equipment entries showing recent technical service notation. The spreadsheet structure captures detailed operational parameters including bridge spans up to 120 feet, runway lengths, lifting heights, motor specifications with voltage and phase information, brake types, and limit switch configurations to support comprehensive maintenance scheduling and compliance verification.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-26-098-B Bid Pricing Form 2026-02-11.xlsx | XLSX spreadsheet | |
| 1-26-098-B Solicitation Packet 2026-02-11.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| HCSG Equipment Number | Customer Equipment # | Out of Service | Equipment Type | Area | Location | Criticality | Crane Type | Equipment Capacity Range | Select Equipment Mfg | Equipment Model No. | Equipment Serial No. | Equipment Capacity | Crane Style | Equip/CraneDriveType | Equipment/Crane Motor Mfg. | Equipment/Crane Pri Amps | Bridge Limit Switch | Number of Motors | Equipment/Crane Motor HP/RPM | Equipment/Crane Motor Voltage | Equipment/Crane Motor Phase | Equip/Crane Motor Steps | Bridge Span | Runway Length | Monorail Length | Jib Mast Height | Jib Boom Length | Number of Ropes/Chains | Hook Tram | Runway Conductor Mfg | Bridge Festoon Mfg. | Hoist Mfg. | Hoist Model No. | Hoist Serial No. | Hoist Capacity | Lifting Height | Lifting Cable Type | Hoist Drive Type | Hoist Brake Type | Load Brake Type | Hoist Pri Amps | Hoist Sec Amps | Hoist Motor HP/RPM | Hoist Motor Volts | Hoist Motor Phase | Hoist Motor Steps | Hoist Limit Switch | Trolley Mfg | Trolley Model No. |
| NTMWD001 | NTMWD001 | Out of Service | Overhead | Blower building | prosper tx blower bldg | Production/Super Critical 20 minutes or less | BRIDGE | 0 to 10 ton | - | na | na | 5 ton | UHSG | ELECTRIC | - | 1725 | 460 | THREE | 1 | 25 ft | 40 ft | 1 | DUCT-O-WIRE | DUCT-O-WIRE | BLACK BEAR | TUDH-500 | 700058 | 5 ton | 20 ft | WIRE ROPE | ELECTRIC | Disc | 460 | THREE | 1 | - | |||||||||||||
| NTMWD002 | 002 | Out of Service | Overhead | UV bldg | Uv | Production/Super Critical 20 minutes or less | BRIDGE | 0 to 10 ton | 1/2 ton | UHSG | ELECTRIC | 2 | 460 | THREE | 1 | 1 | SHAWBOX | 80l5018D18 | 07A08899 | 1/2 ton | 20 ft | WIRE ROPE | ELECTRIC | Disc | 460 | THREE | 1 | ||||||||||||||||||||||
| NTMWD003 | 003 | Out of Service | Winch Derrick | above tanks | above tanks | Production/Super Critical 20 minutes or less | WINCH/DERRICK | 0 to 10 ton | THERN | 5122SSA | 5009-50430 | 500 lbs | JIB | ||||||||||||||||||||||||||||||||||||
| NTMWD004 | 004 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | JIB | 0 to 10 ton | THERN | 5122ssa | 5009-50434 | 500 lbs | |||||||||||||||||||||||||||||||||||||
| NTMWD005 | 005 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | JIB | 0 to 10 ton | THERN | 5122ssa | 5009-50432 | 500 lbs | JIB | ||||||||||||||||||||||||||||||||||||
| NTMWS006 | 006 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | JIB | 0 to 10 ton | THERN | 5122ssa | 5009-50801 | ||||||||||||||||||||||||||||||||||||||
| NTNWD007 | 007 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | THERN | 5122ssa | 5009-50789 | 500 lbs | ||||||||||||||||||||||||||||||||||||||
| NTNWD008 | 008 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | 650083763 | 500 lbs | ||||||||||||||||||||||||||||||||||||||||
| NTMWD009 | 009 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | 500 lbs | |||||||||||||||||||||||||||||||||||||||||
| NTMWD010 | 010 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | WINCH/DERRICK | 0 to 10 ton | 500 lbs | ||||||||||||||||||||||||||||||||||||||||
| NTMWD011 | 011 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | 8650083762 | 500 lbs | ||||||||||||||||||||||||||||||||||||||||
| NTMWD012 | 012 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | 0 to 10 ton | 5122ssa | 5009-50431 | 500lbs | ||||||||||||||||||||||||||||||||||||||||
| NTMWD013 | 013 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | THERN | 5122ssa | 5009-50797 | 500lbs | ||||||||||||||||||||||||||||||||||||||
| NTMWD14 | 014 | Out of Service | Winch Derrick | sludge | sludge | Production/Super Critical 20 minutes or less | 0 to 10 ton | THERN | 5122ssa | 5009-50800 | 500 lbs | ||||||||||||||||||||||||||||||||||||||
| NTMWD015 | 015 | Out of Service | Winch Derrick | sludge tank | sludge tanks | Production/Super Critical 20 minutes or less | WINCH/DERRICK | 11 to 50 ton | 5122ssa | 5009-50802 | 500 lbs | ||||||||||||||||||||||||||||||||||||||
| NTMWD016 | 016 | Out of Service | Winch Derrick | sludge tanks | sludge tanks | Production/Super Critical 20 minutes or less | 0 to 10 ton | 5122ssa | 5009-50435 | 500lbs | |||||||||||||||||||||||||||||||||||||||
| stainless there on hill | Out of Service | Winch Derrick | top of hill | outside | Production/Critical 3 Hours or less | JIB | 0 to 10 ton | THERN | 5110M3SS-57 | 5009-51103 | JIB | MANUAL | - | ||||||||||||||||||||||||||||||||||||
| top of stairs | Out of Service | Winch Derrick | top of stairs | outside | Production/Critical 3 Hours or less | JIB | 0 to 10 ton | THERN | 572M1 | 5007-37594 | JIB | MANUAL | |||||||||||||||||||||||||||||||||||||
| NTMWD 002 | 002 | Out of Service | Winch Derrick | sub pump | outside | Production/Critical 3 Hours or less | JIB | 0 to 10 ton | THERN | 5110M3SS-57 | 5009-51103 | JIB | MANUAL | - | - | - | - | ||||||||||||||||||||||||||||||||
| NTMWD 003 | 003 | Out of Service | Winch Derrick | screening area | outside | Production/Critical 3 Hours or less | JIB | 0 to 10 ton | THERN | 582M1 | 5007-37594 | JIB | MANUAL | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWDBUF-005 | In Service | Overhead | Blower building #2 | Buffalo Creek WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | - | - | - | 1 ton | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWD-WyliePL2-008 | HOI000043 | Out of Service | Overhead | Ozone Lower Level, Wylie PL2, South, 22‐103 | .PLANT 1 | - | MONORAIL | 0 to 10 ton | N/A | N/A | UHSG | MANUAL | - | - | - | - | 34FT | - | - | KONE | XNMS0 500 8LH | G1241572 | 1/2TON | 13.5 | CHAIN | - | - | - | - | - | - | ||||||||||||||||||
| Dummy Form | Out of Service | Overhead | .Dummy Form | .Dummy Form | - | - | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||
| NTMWDBUF-006 | In Service | Overhead | N/A | Buffalo Creek WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||
| NTMG5 | Out of Service | Overhead | #5 | City Of Garland | |||||||||||||||||||||||||||||||||||||||||||||
| NTMWDBUF-007 | In Service | Winch Derrick | Transfer pump unit 2 | Biological Treatment, Unit 2, Buffalo Creek | Production/General Maintenance 24 hours or more | JIB | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||
| TRUCK1262 | 1262 | In Service | Mobile | technical Services | Wylie Plant 1 | Production/General Maintenance 24 hours or more | OTHER- | 0 to 10 ton | PALFINGER | PSC 7229 S032-ST-A | 100486594 | 9700 lbs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||
| NTMWD-Wylie | In Service | Slings Web | ntmwd Wylie technical services | truck 1262 | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | 125629-177 | 12800 | NONE | ||||||||||||||||||||||||||||||||||||||||
| WWTPSC-001 | 19487 | In Service | Overhead | Plant 2, RAS/Was Pump Station | Sabine Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 4370635 | 5 ton | TRSG | - | - | 480 | THREE | - | 60 | 1 | DUCT-O-WIRE | - | DETROIT | 164366 | 5 ton | WIRE ROPE | ELECTRIC | - | - | THREE | - | programmable | - | |||||||||||||||||
| NTMWD-WC 018 | 20080 | In Service | Small Hoist | anoxic zone 3 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | - | 3 | 1 | - | DLB1200A | 500 | WIRE ROPE | MANUAL | Other | - | - | - | |||||||||||||||||||||
| NTMWD-WC 016 | 20081 | In Service | Small Hoist | Anoxic zone 2 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | - | 3 | 1 | - | DLB1200A | 500 | WIRE ROPE | MANUAL | Other | - | - | - | |||||||||||||||||||||
| NTMWD-WC 014 | 20083 | In Service | Small Hoist | anoxic zone 1 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | JIB | MANUAL | - | - | - | - | 3 | 1 | - | DLB1200A | 500 | WIRE ROPE | MANUAL | Other | - | - | - | ||||||||||||||||||||||
| NTMWD-WC 017 | 20083 | In Service | Small Hoist | anoxic zone 2 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | - | - | - | - | 3 | 1 | - | DLB1200A | 500 | WIRE ROPE | Other | - | - | - | |||||||||||||||||||||||
| NTMWD-WC 015 | 20084 | In Service | Small Hoist | Anoxic zone 1 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | - | - | - | - | DLB1200A | 500 | WIRE ROPE | MANUAL | - | - | - | ||||||||||||||||||||||
| NTMWD-WC 012 | 20086 | In Service | Small Hoist | Anaerobic Zone 2 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | - | 3 | - | DLB 1200A | 500 | WIRE ROPE | MANUAL | Other | - | - | - | ||||||||||||||||||||||
| NTMWD-WC 010 | 20087 | In Service | Small Hoist | Anaerobic Zone 1 mixer 2 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | JIB | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | - | 3 ft | 1 | - | 1200 a | 500 | WIRE ROPE | MANUAL | Other | ||||||||||||||||||||||||
| NTMWD-WC 011 | 20088 | In Service | Small Hoist | Anaerobic Zone 1 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | D1A | 500 | JIB | MANUAL | - | - | - | 3 | - | 1200A | 500 | WIRE ROPE | MANUAL | - | - | - | ||||||||||||||||||||||||
| NTMWD-WC 009 | 20089 | In Service | Small Hoist | 0M -345 pre anoxic | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | JIB | 0 to 10 ton | - | B 1200A | 1200 | JIB | MANUAL | - | 1 | - | 1200 | WIRE ROPE | MANUAL | Other | - | - | - | ||||||||||||||||||||||||||
| NTMWDTRMS-001 | 20753 | In Service | Overhead | underground | Trinity River Main Stem PS | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 4370585 | 30t | TRDG | ELECTRIC | 2 | 480 | THREE | 2 | 60 | 118 | 2 | - | - | DETROIT | 164753 | 30t | 42 | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | - | DETROIT | ||||||||||||||||
| NTMWD-WyliePL3-001 | 27455 | Out of Service | Overhead | BLDG H | Wylie Water Plant 3 22-096-B | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | KONE | 1000 lb | MONORAIL | MANUAL | - | - | - | - | 1 | - | - | KONE | X9MSO5008LH | G1241574 | 1000 lb | 17' 6" | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||
| NTMWD-WyliePL3-002 | CRN000038 | Out of Service | Overhead | 1230-I Ozone South | Wylie Water Plant 3 22-096-B | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | KONE | 1000 lbs | MONORAIL | MANUAL | - | - | - | - | 34 | - | - | KONE | X9MSO5008LH | G1241671 | 1000 lbs | 17' 6" | CHAIN | MANUAL | Disc | - | - | - | - | ||||||||||||||||||
| NTMWD-WyliePL3-003 | CRN000029 | Out of Service | Overhead | Plant 3 Chlorine BLDG | Wylie Water Plant 3 22-096-B | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 2000 lb | MONORAIL | - | - | - | - | - | 35' | 1 | - | - | ACC0 LIFT | 1360230 | 136-10-192107 | 2000 lb | 10' | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||
| NTMWD-WyliePL4-001 | 27462 | Out of Service | Overhead | BLDG 30 | Wylie Water Plant 4 22-096-B | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | MANUAL | - | - | - | - | 30' | 1 | - | - | BUDGIT | USA01 | 05AU049 | 2000 lb | CHAIN | MANUAL | Disc | - | - | - | - | |||||||||||||||||||
| WWTPRC-002 | 20986 | In Service | Small Hoist | ferric/ polymer | Rowlet Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | CHAIN | MANUAL | Disc | |||||||||||||||||||||||||||||||
| NTWMD-WC-025 | 21332 | In Service | Overhead | WILSON CREEK | Wilson Creek WWTP | MONORAIL | 0 to 10 ton | 1/2 TON | UHSG | MANUAL | 40ft | CYCLONE | S6608YS | 1/2 TON | 20FT | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||
| NTMWD-WC033 | 21377 | In Service | Small Hoist | Sulfur Dioxide | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | COFFING | JLC4008-3-LCX | JMB5174ZV | 2 ton | CHAIN | ELECTRIC | Disc | 480 | THREE | ||||||||||||||||||||||||||||||
| NTWMD- WC-026 | 26005 | In Service | Overhead | UV BASIN NO 605 | WILSON CREEK WWTP | MONORAIL | 0 to 10 ton | 1/2 TIN | UHSG | CYCLONE | S6607YS | 1/2 TON | 20FT | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||||
| NTMWD-WC034 | 26031 | In Service | Overhead | UV 611 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | GORBEL | 580832 | 500 lb | UHSG | MANUAL | - | COFFING | JLC4008-3-LCX | JMB1154ZT | 500 lb | 10 | CHAIN | Disc | 1 | |||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-004 | 26814 | Out of Service | Slings Web | Facilities Service 810-H | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 11 to 50 ton | UNION | 1074759-1-2 | 50,000 basket | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-005 | 26815 | Out of Service | Slings Web | Facilities Service 810-H | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 11 to 50 ton | UNION | 1074759-1-1 | 50,000 basket | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-006 | 26817 | Out of Service | Slings Web | Technical Support | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 11 to 50 ton | - | 1153385-08 | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-007 | 26819 | Out of Service | Slings Web | Technical Support 401-S | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 0 to 10 ton | - | E2802P | 12,800 lbs in basket | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-008 | 26820 | Out of Service | Slings Web | Technical Support 401-S | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 11 to 50 ton | - | 1124808-299 | 26,400 | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-007 | CRN000008 | Out of Service | Overhead | HSPS 2-3 | Wylie Water Plant 2 22-096-B | Production/General Maintenance 24 hours or more | 0 to 10 ton | - | 10 t | TRSG | ELECTRIC | 1 | 480 | THREE | 1 | SHAWBOX | 73 10026014 | 00B07757 | 20,000 lb | WIRE ROPE | ELECTRIC | Disc | wet | 480 | THREE | 2 | gear limit | SHAWBOX | |||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-009 | 26823 | Out of Service | Slings Wire Rope | Technical Support 401-S | Wylie Water Plant 2 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | - | 0 to 10 ton | - | 1055967-1 | 2000 lbs | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTWMD-WC-028 | 26041 | In Service | Overhead | UV 601 602 603 | Wilson Creek WWTP | JIB | 0 to 10 ton | ACE GAFFEY | 2497417-1 | 1/2 TON | JIB | HARRINGTON | 1/2 TON | 20FT | CHAIN | MANUAL | Disc | ||||||||||||||||||||||||||||||||
| NTMWD-PlanoPS2-001 | 26134 | In Service | Overhead | #2 | City Of Plano PS2 | - | - | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | - | - | BUDGIT | USA01 | USA3384YP | 1 ton | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||||||
| NTMWDWC-004 | 26139 | In Service | Overhead | CENTRIFUGE BLDG | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | MATERIAL HANDLING SYSTEMS | 15 ton | TRDG | ELECTRIC | 2 | 480 | THREE | 2 | 35 | 70 | DETROIT | 165429 | 15 ton | 30 | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | |||||||||||||||||||||
| NTWMD-WC-027 | 26267 | In Service | Overhead | UV 604 | Wilson Creek WWTP | BRIDGE | 0 to 10 ton | GORBEL | 580932 | 500 LBS | UHDG | COFFING | JLC0516 | JMA1502WG | 1/4 TON | 10FT | CHAIN | Disc | |||||||||||||||||||||||||||||||
| NTMWD-SC035 | 26278 | In Service | Overhead | UV612 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | GORBEL | 500 lb | UHSG | MANUAL | - | - | - | - | COFFING | JLC0516 | JMA1501WG | 500 | CHAIN | ELECTRIC | Disc | SINGLE | 1 | ||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-001 | 26810 | In Service | Slings Wire Rope | Facilities Service 810-H | Wylie Water Plant 2 | Stand By Maintenance/General Maintenance 24 hours or more | - | 0 to 10 ton | UNION | 101818-10-2 | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-002 | 26812 | In Service | Slings Wire Rope | Facilities Service 810-H | Wylie Water Plant 2 | Stand By Maintenance/General Maintenance 24 hours or more | - | 0 to 10 ton | UNION | 101818-10-1 | 16,600 | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-003 | 26813 | In Service | Slings Wire Rope | Facilities Service 810-H | Wylie Water Plant 2 | Stand By Maintenance/General Maintenance 24 hours or more | - | 0 to 10 ton | DELTA | 122332 | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||||||||
| NTWMD | 26814 | In Service | Slings Chain | WAREHOUSE | Wylie Water Plant 2 | 0 to 10 ton | |||||||||||||||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-014 | 26824 | In Service | Small Hoist | Technical Services | Wylie Water Plant 2 | Stand By Maintenance/General Maintenance 24 hours or more | OTHER- | 0 to 10 ton | - | - | - | - | - | - | - | - | - | CMS | loadstar | L3514UT | 6000 lb | CHAIN | ELECTRIC | Disc | 110 | SINGLE | 1 | - | |||||||||||||||||||||
| NTMWD-WC046 | 26827 | In Service | Structural Mechanical Lifting Device | bldg 302 outside of side door | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | 0 to 10 ton | CALDWELL GROUP | 20-7 1/2-8 | 1895545 | 7.5 ton | NONE | - | ||||||||||||||||||||||||||||||||||||
| NTMWD-WC039 | 26940 | In Service | Overhead | Sludge waste pump room downstairs | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | GANTRY | 0 to 10 ton | - | 58021 | NFJL57021211106 | 1 ton | GANTRY | NONE | - | - | 8 | ||||||||||||||||||||||||||||||||
| NTMWD-WC-023 | 26941 | In Service | Overhead | SECONDARY SLUDGE PUMP NO 3 | Wilson Creek WWTP | GANTRY | 0 to 10 ton | NF2L57021200110 | 4000LBS | GANTRY | MANUAL | ||||||||||||||||||||||||||||||||||||||
| NTMWD-WyliePL3-006 | 27451 | Out of Service | Overhead | BUILDING 1320-I OZONE LOWER LEVEL SOUTH | Wylie Water Plant 3 22-096-B | - | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWDPC-017 | 26999 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50798 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-018 | 27000 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122 SSA | 5009-50801 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-019 | 27001 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50432 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-020 | 27002 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50434 | ||||||||||||||||||||||||||||||||||||||||
| NTMWD-TRKCRN-001 | 0819 | Out of Service | Mobile | Mobile | Truck Crane | Stand By Maintenance/General Maintenance 24 hours or more | MOBILE | 0 to 10 ton | STELLAR | 7621 | BGM13C961 | 5Ton | - | HYDRAULIC | - | - | - | - | 21.6’ | 1 (3/8”, 100’ long, thimble eye end) | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||
| NTMWD-WyliePL1-001 | NTMWD001 | Out of Service | Overhead | 810-B HSPS1-1 | Wylie PL1 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | KONE | K13007 | 20000lbs | UHSG | ELECTRIC | mf06LA100-131F81001EIP55 | 2 | 4560 | 480 | - | 2 | 46'9" | 94' | n/a | 1 | - | KONE | CXT5040100P55FDLOS | 10184908 | 10Ton | 28' | WIRE ROPE | ELECTRIC | Other | 19A | 480 | THREE | 2 | geared | ||||||||||||
| NTMWDPC-015 | 27003 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | 650083763 | 300kg | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-016 | 27004 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | |||||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-021 | 27005 | In Service | Winch Derrick | AB 1 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50430 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-010 | 27006 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | THERN | 5122SSA | 5009-50797 | |||||||||||||||||||||||||||||||||||||||
| NTMWDPC-011 | 27007 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | THERN | 5122SSA | 5009-50431 | JIB | ||||||||||||||||||||||||||||||||||||||
| NTMWDPC-012 | 27008 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | THERN | 5122SSA | 5009-50800 | |||||||||||||||||||||||||||||||||||||||
| NTMWDPC-013 | 27009 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50802 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-009 | 27010 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | ||||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-008 | 27011 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | 650083762 | 300kg | JIB | |||||||||||||||||||||||||||||||||||||||
| NTMWDPC-014 | 27012 | In Service | Winch Derrick | AB 2 | Panther Creek WWTP | 0 to 10 ton | THERN | 5122SSA | 5009-50435 | ||||||||||||||||||||||||||||||||||||||||
| NTMWDPC-007 | 27014 | In Service | Winch Derrick | Primary clarifier | Panther Creek WWTP | JIB | 0 to 10 ton | THERN | 5PF5G | 5021-111960 | JIB | ||||||||||||||||||||||||||||||||||||||
| NTWMD-WC-029 | 27045 | In Service | Overhead | UV 601 602 603 | Wilson Creek WWTP | JIB | 0 to 10 ton | ACE GAFFEY | 2497417-2 | 1/2TON | JIB | HARRINGTON | 1/2 TON | 20FT | CHAIN | MANUAL | |||||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-010 | 26824 | Out of Service | Slings Web | 401-S Technical Services | Wylie Water Plant 2 22-096-B | Production/Super Critical 20 minutes or less | 0 to 10 ton | FE28061 | 12,000 lbs | ||||||||||||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-011 | 27071 | Out of Service | Slings Web | Tech Serv 401-S | Wylie Water Plant 2 22-096-B | Production/Super Critical 20 minutes or less | 0 to 10 ton | No Tag | |||||||||||||||||||||||||||||||||||||||||
| NTMWD-Wylie PL2-012 | 27072 | Out of Service | Slings Web | 401-S | Wylie Water Plant 2 22-096-B | Production/Super Critical 20 minutes or less | 11 to 50 ton | UNION | HWR-EE296X20’ | 32331-2-4 | 33,000 lbs | ||||||||||||||||||||||||||||||||||||||
| NTMWD-Wylie PL2-013 | 27073 | Out of Service | Slings Web | Facility Services | Wylie Water Plant 2 22-096-B | Production/Super Critical 20 minutes or less | 0 to 10 ton | N/A | N/A | N/A | |||||||||||||||||||||||||||||||||||||||
| NTMWD-WyliePL2-RGNG-014 | 27539 | Out of Service | Slings Web | 810-H | Wylie Water Plant 2 22-096-B | Production/Super Critical 20 minutes or less | 11 to 50 ton | ENR5PD | 1124808-293 | 26,400 lbs | |||||||||||||||||||||||||||||||||||||||
| NTMWD-WC 013 | 27069 | In Service | Small Hoist | NRCY PUMP 1 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | OZTP1200DAV | TP1200541 | 1200 | JIB | MANUAL | - | - | - | - | 4 | 1 | - | OZWINHND1 | DL120051 | 1200 | WIRE ROPE | MANUAL | Other | - | - | ||||||||||||||||||||
| NTWMD | 27073 | In Service | Slings Chain | WELD SHOP | Wylie Water Plant 2 | 0 to 10 ton | 211977-3 | ||||||||||||||||||||||||||||||||||||||||||
| NTMWDWC-003 | 27108 | In Service | Small Hoist | primary clarifier | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | JIB | 0 to 10 ton | THERN | 5PT10S316-M3 | 5018-97407 | 1200 lb | JIB | 6 | THERN | M4312PBSS-K | 1200 | WIRE ROPE | MANUAL | ||||||||||||||||||||||||||||||
| NTWMD | 27453 | In Service | Small Hoist | WAREHOUSE | Wylie Water Plant 2 | 0 to 10 ton | 1810110458 | 1 TON | CHAIN | ||||||||||||||||||||||||||||||||||||||||
| NTMWD-WyliePL1-003 | 27454 | In Service | Small Hoist | BUILDING 810-A OZONE | Wylie Water Plant 1 | - | MONORAIL | 0 to 10 ton | - | N/A | N/A | - | - | - | - | - | - | 34FT | - | - | KONE | XNMS0 500 8LH | G1241572 | 1/2 TON | 13.5 | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||
| NTMWD-WyliePL3-004 | 27456 | In Service | Overhead | BUILDING 1320-A OZONE OPPS EAST HOIST | Wylie Water Plant 3 | - | MONORAIL | 0 to 10 ton | - | N/A | N/A | 1 TON | MONORAIL | CHAIN/GEAR | - | - | - | - | 29 FT | - | - | KONE | XNMS1 000 SLH | G1241527 | 1 TON | 13.4 | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||
| NTMWD-WyliePL3-005 | 27457 | In Service | Overhead | BUILDING 1320-A OZONE WEST | Wylie Water Plant 3 | - | MONORAIL | 0 to 10 ton | - | N/A | N/A | 1 TON | MONORAIL | - | - | - | - | - | 30 FT | - | - | KONE | XNMS1 000 8LH | G1241566 | 1 TON | 9.8 FT | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||
| NTMWDCL-002 | 27465 | In Service | Overhead | Pump Station - Lower Level Far Left Side | Cooper Lake (Chapman) RWPS | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | - | - | BUDGIT | ZLG-2430 | 6 ton | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||||||
| NTMWDCL-003 | 27466 | In Service | Overhead | Pump Station - Lower Level Close Side | Cooper Lake (Chapman) RWPS | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 6 ton | MONORAIL | - | - | - | - | - | - | - | BUDGIT | ZLG-2431 | 6 ton | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||||||
| NTMWDCL-005 | 27467 | In Service | Engine Hoist Lifts | Pump station - Portable | Cooper Lake (Chapman) RWPS | Production/General Maintenance 24 hours or more | - | 0 to 10 ton | - | GW-2006 | 035689 | 300 | - | MANUAL | - | - | - | - | - | - | |||||||||||||||||||||||||||||
| NTMWD-CoLucas-001 | 27658 | In Service | Overhead | 2295 McGarity ln Lucas Tx. | City of Lucas 1 PS | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWD-CoForney-001 | 27660 | In Service | Overhead | WA3521-A | City of Forney PS2 | - | - | 0 to 10 ton | - | N/A | N/A | N/A | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||
| NTMWDKAUF. 4-1 | 27661 | In Service | Overhead | Kaufman 4in1 PS WA 3533 | Kaufman 4in1 | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | 0 | - | - | - | - | - | - | - | - | - | - | |||||||||||||||||||||||
| NTMWDCOP-001 | 27662 | In Service | Overhead | Pump station | City of Princeton PS1 22-096- B | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWDCOF-001 | 27663 | In Service | Overhead | WA-3522-A | City of frisco PS1 | - | MONORAIL | 0 to 10 ton | - | MONORAIL | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWD-Sachse-001 | 27666 | In Service | Overhead | City of Sachse 6436 Sachse rd Sachse Tx | City of Sachse PS2 | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| WWTPBEAR-001 | HO100030 | Out of Service | Winch Derrick | First | Digesters 1-3, Bear Creek, WWTP | Production/General Maintenance 24 hours or more | 0 to 10 ton | D2A | 1000# | MANUAL | |||||||||||||||||||||||||||||||||||||||
| WWTPBEAR-002 | HO100031 | Out of Service | Winch Derrick | Second | Digesters 1-3, Bear Creek, WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | D2A | 1000 | |||||||||||||||||||||||||||||||||||||||
| WWTPBEAR-003 | HO1000032 | Out of Service | Winch Derrick | Third | Digesters1-3, Bear Creek, WWTP | Production/General Maintenance 24 hours or more | JIB | 0 to 10 ton | D2A | 1000# | |||||||||||||||||||||||||||||||||||||||
| NTMWDCOG002 | 27667 | In Service | Overhead | 2 PS | City Of Garland PS2 | - | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWDCOG001 | 27668 | In Service | Overhead | Pump Station 2 | City Of Garland Pump Station 2 | MONORAIL | 0 to 10 ton | MONORAIL | NONE | - | - | - | 10 | ||||||||||||||||||||||||||||||||||||
| NTMWDRC-001 | CRN000009 | Out of Service | Overhead | Secondary Sludge PS TrainB Rowlett Creek | bldg B | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 98-2060-1 | 3 t | TRSG | - | 11ft | 39ft | i | - | - | BUDGIT | 10/98 | 3t | 10ft | MANUAL | Disc | - | ||||||||||||||||||||||||
| NTMWDRC-002 | CRN000024 | Out of Service | Overhead | Blower bldg Train B Rowlett Creek | Bldg G | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 98-2060-2 | 5 T | UHSG | MANUAL | 24 | 40 | 1 | SHAWBOX | 72L050118D13 | 98J01706 | 5 TON | 15ft | WIRE ROPE | ELECTRIC | Disc | |||||||||||||||||||||||||
| NTMWDRC-003 | MRL000001 | Out of Service | Overhead | NTMWDRC Rowlett Creek WW1000-D | bldg D | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 2t | MONORAIL | 1 | COFFING | JLCMT4008 | JMA6733WH | 2 TON | 10 ft | CHAIN | ELECTRIC | Disc | |||||||||||||||||||||||||||||
| NTMWDRC-004 | MRL000002 | Out of Service | Overhead | chlorine (cl2) Storage bldg Rowlett Creek | bldg e | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | ELECTRIC | COFFING | EC.4003.3 | EC1.C.228.JCD | 2t | CHAIN | |||||||||||||||||||||||||||||||||
| NTMWDRC-5 | MRL000002 | Out of Service | Overhead | Chlorine (CL2) Storage Bldg Rowlett Creek WW1000-E | bldg E | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 2t | COFFING | JLCUTM4008 | JMA6275VF | 2t | 10 | CHAIN | ELECTRIC | ||||||||||||||||||||||||||||||||
| ntmwd-com ps3 | 27669 | In Service | Overhead | City of Mesquite PS3 | City of Mesquite PS3 | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | unk | MONORAIL | NONE | - | - | - | - | 15 | - | - | ||||||||||||||||||||||||||||||
| NTMWDCL-004 | 27672 | In Service | Engine Hoist Lifts | Pump station - Portable | Cooper Lake (Chapman) RWPS | Production/General Maintenance 24 hours or more | - | 0 to 10 ton | GENIE | SLA-10 | SLA02-16710 | - | MANUAL | - | - | - | - | - | - | ||||||||||||||||||||||||||||||
| NTMWDLTRW-002 | 27674 | In Service | Below The Hook Devices | Ground | Lake tawakoni raw water PS | Production/General Maintenance 24 hours or more | - | 11 to 50 ton | - | 15 ton | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||||||||
| NTMWDTRMS-002 | 27675 | In Service | Engine Hoist Lifts | Electrical room | Trinity River Main Stem PS | Production/General Maintenance 24 hours or more | - | 0 to 10 ton | - | GW-2006 | 040300 | 1000lbs | - | - | - | - | - | - | - | - | |||||||||||||||||||||||||||||
| ntmwdcasaview | 27676 | In Service | Pallet Jack | Pump Station | Casa View PS (Mesquite 2) | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | - | GW-2006 | 039778 | 300 lbs | ||||||||||||||||||||||||||||||||||||||
| NTMWD-FOR2TER-001 | 27677 | In Service | Winch Derrick | WA3587-A | Forney to Terrell PS | - | WINCH/DERRICK | 0 to 10 ton | - | GE power/Vac lift truck | 1500 LBS | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||
| NTMWD-CoRockwall-001 | 27680 | In Service | Overhead | Pump Station 2 | City of Rockwall PS2 | - | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWDWC-005 | 28121 | In Service | Small Hoist | CENTRIFUGE BLDG ( up stairs) | Wilson Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | MONORAIL | - | 20 | 1 | CMS | 1 ton | 15 | CHAIN | MANUAL | Disc | - | ||||||||||||||||||||||||||||||
| WWTPFLS-001 | 28276 | In Service | Overhead | Upper level | Farmersville Lift Station WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | 0ZK200008 | OZK20000028 | 1 ton | 40 | CHAIN | ELECTRIC | - | - | - | - | - | ||||||||||||||||||||
| WWTPFLS-002 | 28277 | In Service | Overhead | Lower level | Farmersville Lift Station WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | COFFING | CB 1.226.HDA | 1 ton | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||||||
| NTMWDTWT-002 | 28684 | In Service | Overhead | Lower level | Tawakoni water treatment plant WTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | 48 | na | - | - | DETROIT | 154623 | 5 ton | WIRE ROPE | ELECTRIC | - | - | - | - | - | ||||||||||||||||||||
| NTMWD-WC044 | 29285 | In Service | Overhead | North RAS Basement | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | GANTRY | 0 to 10 ton | - | NFJL57021211204 | 1 ton | GANTRY | - | - | - | - | |||||||||||||||||||||||||||||||||
| NTMWD-WC045 | 29286 | In Service | Overhead | Building 202 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | GANTRY | 0 to 10 ton | - | 57021 | NFJL57021211204 | 1 ton | GANTRY | NONE | - | ||||||||||||||||||||||||||||||||||
| NTMWD-WC 019 | 30958 | In Service | Small Hoist | anoxic zone 3 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | JIB | MANUAL | 3 | 1 | - | DLB2500A | WIRE ROPE | MANUAL | ||||||||||||||||||||||||||||||||
| NTMWD-WC 020 | 30964 | In Service | Small Hoist | BNR BASIN NO. 12 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | THERN | 5PT10S | 5019-101122 | 1200 | JIB | MANUAL | THERN | M4312PBSS-K | WIRE ROPE | MANUAL | Other | ||||||||||||||||||||||||||||||
| NTMWD-WC-001 | 30965 | In Service | Overhead | maintenance shop/ loc. S | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | KONE | 100646722 | 15 ton | TRDG | - | yes | 2 | - | THREE | - | 34 | 60 | 1 6 falls | - | - | KONE | CXT50610150P55FDD0S | 100723990 | 15 ton | 16' | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | - | KONE | ||||||||||||||
| NTMWD-WC047 | 31516 | In Service | Structural Mechanical Lifting Device | bldg 102 red barn bldg | Wilson Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | 2 ton | - | ||||||||||||||||||||||||||||||||||||||||
| WETPMC-007 | 32451 | In Service | Overhead | N/A | MUDDY CREEK | - | GANTRY | 0 to 10 ton | - | - | - | - | - | - | - | - | - | JET | S90-200 | 20042295 | 2 TON | - | - | - | - | - | - | - | |||||||||||||||||||||
| WWTPSM-007 | WWTPSM | Out of Service | Winch Derrick | DISC FILTER | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | THERN | THERN | M4042PBSS | |||||||||||||||||||||||||||||||||||||||
| WWTPSM-008 | N/A | Out of Service | Winch Derrick | SECONDARY 4 | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | JIB | - | N/A | N/A | ||||||||||||||||||||||||||||||||||||||
| WWTPSM-009 | N/A | Out of Service | Winch Derrick | SECONDARY 3 | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
| WWTPSM-010 | N/A | Out of Service | Winch Derrick | SCUM PUMP | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | JIB | THERN | M4042PBSS | |||||||||||||||||||||||||||||||||||||||
| WWTPSM-011 | N/A | Out of Service | Winch Derrick | AERATION BASIN # 6 NRCY PUMP | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | S-K1550 | |||||||||||||||||||||||||||||||||||||||||
| WWTPSM-012 | N/A | Out of Service | Winch Derrick | AERATION BASIN # 5 NRCY PUMP | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||
| WWTPSM-013 | N/A | Out of Service | Winch Derrick | AERATION BASIN # 4 NRCY PUMP | SOUTH MESQUITE CREEK | WINCH/DERRICK | 0 to 10 ton | S-K1550 | N/A | ||||||||||||||||||||||||||||||||||||||||
| WWTPSM-014 | N/A | Out of Service | Small Hoist | MAINTENANCE SHOP | SOUTH MESQUITE CREEK | OTHER- | 0 to 10 ton | 31380086 | 3/4 TON | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||||||||
| WWTPSM- 015 | N/A | Out of Service | Small Hoist | MAINTENANCE SHOP | SOUTH MESQUITE CREEK | OTHER- | 0 to 10 ton | COFFING | LSB-B | ZX0255 | 1 1/2 TON | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||||||
| WWTPSM-016 | N/A | Out of Service | Small Hoist | MAINTENANCE SHOP | SOUTH MESQUITE CREEK | OTHER- | 0 to 10 ton | DAYTON | 5YGF5A | 550 LBS | CHAIN | MANUAL | |||||||||||||||||||||||||||||||||||||
| WWTPSM-017 | N/A | Out of Service | Small Hoist | MAINTENANCE SHOP | SOUTH MESQUITE CREEK | OTHER- | 0 to 10 ton | 31380096 | 3/4 | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||||||||
| WWTPSM-001 | Out of Service | Overhead | blower bldg | South Mesquite Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | - | 6860 | 4 t | UHSG | MANUAL | CHESTER | AG-8831 | 4t | 20 | CHAIN | MANUAL | CHESTER | ||||||||||||||||||||||||||||||
| wwtpsm-004 | Out of Service | Overhead | wwtpsm | UV | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 4370657 | 1 t | TRSG | ELECTRIC | 480 | THREE | DETROIT | 165945 | 1t | 15 | WIRE ROPE | 480 | THREE | ||||||||||||||||||||||||||||
| 1154 | Out of Service | Aerial Lift | NTMWD | yard | Production/General Maintenance 24 hours or more | 0 to 10 ton | JLG | 450AJ | 0300236201 | HYDRAULIC | |||||||||||||||||||||||||||||||||||||||
| 0540 | Out of Service | Aerial Lift | ntmwd | Willie | Production/General Maintenance 24 hours or more | 0 to 10 ton | GENIE | Z-45/25 | Z452508A-36744 | ||||||||||||||||||||||||||||||||||||||||
| 0992 | Out of Service | Aerial Lift | ntmwd | Willie | Production/General Maintenance 24 hours or more | 0 to 10 ton | JLG | 450AJ | 709264033279 | ||||||||||||||||||||||||||||||||||||||||
| 1305 | Out of Service | Aerial Lift | Technical Services | NTMWD WYLIE PL2 | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | GENIE | TZ-50 HYBRID w/Drive | TZ50J-3980 | 500lbs | - | Honda | 1 | ||||||||||||||||||||||||||||||||||||
| 1297 | Out of Service | Mobile | ntmwd Willie | technical Services | Production/General Maintenance 24 hours or more | MOBILE | 0 to 10 ton | PALFINGER | EP2025 | 1906052 | 6000 lb | - | |||||||||||||||||||||||||||||||||||||
| NTMWDPC-004 | 5516 | In Service | Overhead | Blower Bldg | Panther Creek WWTP | GANTRY | 0 to 10 ton | 57012 | NFJL57021171113 | 1 ton | GANTRY | ||||||||||||||||||||||||||||||||||||||
| 1207 | 1207 | Out of Service | Mobile | technical Services | NTMWD WYLIE | Production/General Maintenance 24 hours or more | OTHER- | 0 to 10 ton | HF 320878000 | 2200 lb | - | - | AUTO CRANE | ECH 32 | 320878000 | 2200 lb | 16 | CHAIN | |||||||||||||||||||||||||||||||
| 1307 | 1307 | Out of Service | Mobile | NTMWD WYLIE | technical Services | Production/General Maintenance 24 hours or more | MOBILE | 0 to 10 ton | PALFINGER | PCS 6025 | S038-SY-A100508664 | 4450 | - | PALFINGER | EL 2025 | 1811069 | 4450 | 20 | WIRE ROPE | HYDRAULIC | |||||||||||||||||||||||||||||
| 32884 | 32884 | Out of Service | Pallet Jack | NTMWD WYLIE | technical Services | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | GENIE | SLA 10 | SLA06-32884 | 800 | ||||||||||||||||||||||||||||||||||||||
| 1125 | 1125 | Out of Service | Aerial Lift | NTMWD WYLIE | PS 2-2 | Stand By Maintenance/General Maintenance 24 hours or more | 0 to 10 ton | GENIE | GS-1930 | GS30P465 01 | 500 | ||||||||||||||||||||||||||||||||||||||
| NTMWD-WylieRawPS1 | 8100 | In Service | Overhead | Skyview DR. Pump Station BLDG. Raw Water 1 | Wylie Raw Water PS1 | Production/General Maintenance 24 hours or more | - | 0 to 10 ton | CMS | 20000 | TRDG | ELECTRIC | 1 | 460 | THREE | - | 48' | 70' | 1 | - | - | R&M | SX60220100P64EGD0S | 10000605679 | 20000 lb | WIRE ROPE | ELECTRIC | - | 460 | THREE | - | - | |||||||||||||||||
| WWTPRC-006 | 9510 | In Service | Overhead | S02 Storage bldg | Rowlet Creek WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | MONORAIL | COFFING | JLCMC4008 | JMA6733WH | 2ton | CHAIN | ELECTRIC | 480 | THREE | |||||||||||||||||||||||||||||||
| NTMWD-ForneyTECHSERV-001 | 9992 | In Service | Overhead | BUILDING 105 | Forney Technical Service Building 22-096-B | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 4370603 | 6.5 TON | UHSG | ELECTRIC | 2 | - | THREE | - | 35 FT | 65 FT | - | - | DETROIT | N/A | 163921 | 6.5 | 18 FT | WIRE ROPE | ELECTRIC | Disc | - | - | - | - | ||||||||||||||||
| WWTPSC-005 | N/A | Out of Service | Winch Derrick | Clarifier 1 | Stewart Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | THERN | ||||||||||||||||||||||||||||||||||||||||
| WWTPFB-001 | CRN000018 | Out of Service | Overhead | UV building | UV Structure, Floyd Branch | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 429557-1 | 1 ton | TRSG | ELECTRIC | 2 | YALE | 80102034018 | SH6197NB | 1 ton | WIRE ROPE | ELECTRIC | |||||||||||||||||||||||||||||
| WWTPFB-002 | HO1000016 | Out of Service | Overhead | Small bldg by UV | Storage warehouse, Floyd branch | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | COFFING | EC-4008.3 | EC1A-200.LUD | 2 ton | CHAIN | ELECTRIC | Disc | ||||||||||||||||||||||||||||||||||
| WWTPFB-003 | N/A | Out of Service | Overhead | Biomag | Floyd branch | Production/General Maintenance 24 hours or more | GANTRY | 0 to 10 ton | SPANCO | 1A1210 | VN1131-001 | 1 ton | GANTRY | ACC0 LIFT | 2330020 | UC2106035 | 1 ton | CHAIN | ELECTRIC | ||||||||||||||||||||||||||||||
| WWTPFB-004 | N/A | Out of Service | Overhead | Biomag | Floyd branch | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | ACC0 LIFT | 2130160 | UA2109043 | 3 ton | CHAIN | ELECTRIC | ACC0 LIFT | 2130160 | |||||||||||||||||||||||||||||||||
| WWTPFB-005 | N/A | Out of Service | Overhead | Biomag | Floyd branch | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | ACC0 LIFT | 2130160 | UA2106029 | 3 ton | CHAIN | ELECTRIC | ACC0 LIFT | 2130160 | |||||||||||||||||||||||||||||||||
| WWTPSM-002 | CRN000022 | Out of Service | Overhead | Blower building #1 | Blower bldg #1,Aeration, S Mesquite Creek | BRIDGE | 0 to 10 ton | ACECO | 1109 | 2 ton | TRSG | MANUAL | ACCO WRIGHT | 06 | 106 06 20335 | 2 ton | CHAIN | MANUAL | |||||||||||||||||||||||||||||||
| WWTPSM-003 | CRN000025 | Out of Service | Overhead | Maintenance shop | Maintenance Shop, S Mesquite Creek | BRIDGE | 0 to 10 ton | ACECO | 1110 | 2 ton | UHSG | CHAIN/GEAR | ACCO WRIGHT | 06 | 106-06-20239 | 2 ton | 25 | CHAIN | CHAIN/GEAR | ||||||||||||||||||||||||||||||
| WWTPSM-005 | HO1000021 | Out of Service | Overhead | Old chlorine storage | Storage Bldg, S Mesquite Creek | MONORAIL | 0 to 10 ton | SHAWBOX | 110101-15 | K8-66535 | 2 ton | WIRE ROPE | ELECTRIC | Disc | |||||||||||||||||||||||||||||||||||
| WWTPSM-006 | N/A | Out of Service | Overhead | Test area | S. Mesquite Creek | BRIDGE | 0 to 10 ton | - | 6850 | 2 ton | UHSG | R&M | DB-2-24 | 161016AN1 | 2 tons | WIRE ROPE | |||||||||||||||||||||||||||||||||
| WWTPUR-001 | Out of Service | Overhead | Ground level | Upper Rowelette Creek Lift Station | GANTRY | 0 to 10 ton | SPANCO | 10A10-9216-VG | VI0716-001-A | 10 ton | GANTRY | MANUAL | HARRINGTON | ER2A-65SY7842 | 00213083 | 10 ton | CHAIN | ELECTRIC | Shoe | HARRINGTON | TF1C-214S | ||||||||||||||||||||||||||||
| NTMWDWC-002 | ADD | In Service | Small Hoist | North Ras bldg 009 | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 1500 lb | MONORAIL | NONE | 15 | HARRINGTON | NTH4-4008 | J218051 | 1500 lb | 11 | CHAIN | MANUAL | Disc | - | - | - | |||||||||||||||||||||||||
| WWTPUC-001 | HO1000013 | Out of Service | Overhead | Overhead | Upper Cottonwood Creek Lift Station | BRIDGE | 0 to 10 ton | ACE GAFFEY | 1360 | 7.5 ton | UHSG | BEEBE | C3H080 | 12-86-1 | 8 ton | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||
| WWTPPUWR-001 | HO100012 | Out of Service | Overhead | Underground | Plano Upper White Rock Creek Lift Station | BRIDGE | 0 to 10 ton | ANCHOR | 104996 | 5 ton | UHSG | BUDGIT | 8307 | 9-94 | 5 ton | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||
| NTMWDWC040 | CRN000001 | In Service | Overhead | Wilson Creek | Wilson Creek WWTP | - | BRIDGE | 0 to 10 ton | KRANCO | 9733 | 10 TON | TRDG | ELECTRIC | - | - | - | - | 25ft | 40ft | - | - | R&M | 150400RD1 | 10 TON | 25FT | WIRE ROPE | ELECTRIC | Disc | - | - | - | - | |||||||||||||||||
| NTMWD-WC-041 | CRN000002 | In Service | Overhead | HVLP BLOWER ROOM | Wilson Creek WWTP | BRIDGE | 0 to 10 ton | ACE GAFFEY | SHAWBOX | 327372-20 | L8-66530 | 10 TON | ELECTRIC | Disc | |||||||||||||||||||||||||||||||||||
| NTMWD-WC038 | CRN000005 | In Service | Overhead | sludge waste pump room downstairs | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | KRANCO | 9835 | 2 ton | UHSG | MANUAL | - | - | - | - | 60 | CHESTER | AO 7490 | 2 ton | 20 | CHAIN | MANUAL | - | - | |||||||||||||||||||||||
| NTMWD-WyliePL2-006 | CRN000007 | In Service | Overhead | HSPS 2-2 | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | - | C804241 | 10 t | TRDG | ELECTRIC | 1 | 480 | THREE | 2 | 45' | - | - | SHEPARD NILE | KR1L6L1 | 69707-H | 10 t | 18' | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | - | |||||||||||||||||
| NTMWDWylie-2-3 | CRN000008 | In Service | Overhead | HSPS 2-3 | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 15 ton | TRDG | ELECTRIC | - | - | - | - | 60 | 200 | - | - | YALE | T015T | LK0371Q | 15t | 30 | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | - | YALE | |||||||||||||||||
| WWTPRC-001 | CRN000009 | In Service | Overhead | Bldg B sludge pump room | Rowlet Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 98-2060-1 | 3t | UHSG | MANUAL | - | - | - | 15 | 35 | 2 | BUDGIT | ua | ua | 3 t | 12 | CHAIN | MANUAL | Disc | - | |||||||||||||||||||||
| NTMWDWC-006 | CRN000010 | In Service | Overhead | blower bldg 303 | Wilson Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 2373543 | 4.4 ton | UHSG | ELECTRIC | 2 | 480 | 2 | DETROIT | 148805 | 4.4 ton | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | ||||||||||||||||||||||||
| NTMWD-LCCLS-001 | HOI000030 | Out of Service | Overhead | Tech to Change | Lower Cotton Wood Creek Lift Station | ||||||||||||||||||||||||||||||||||||||||||||
| NTMWD-SC-002 | HOI000041 | Out of Service | Overhead | Tech to Change | Sabine Creek WWTP | ||||||||||||||||||||||||||||||||||||||||||||
| NTMWD-SC-001 | HOI000042 | Out of Service | Overhead | Tech To Change | Sabine Creek WWTP | ||||||||||||||||||||||||||||||||||||||||||||
| NTMWDCL-001 | CRN000015 | In Service | Overhead | Pump station - Main runway | Cooper Lake (Chapman) RWPS | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 1759-FC | 40 ton | TRDG | ELECTRIC | 2 | 480 | THREE | - | 43 | 120 | - | - | DETROIT | 144943 | 40 ton | WIRE ROPE | ELECTRIC | - | - | - | - | - | ||||||||||||||||||
| NTMWDPC-001 | CRN000016 | In Service | Overhead | UV Bldg. | Panther Creek WTP | - | BRIDGE | 0 to 10 ton | ACE GAFFEY | 1/2 ton | TRSG | ELECTRIC | - | - | - | - | - | - | SHAWBOX | 801 .5018D18 | 07A08899 | 1/2 ton | WIRE ROPE | ELECTRIC | - | - | - | - | - | ||||||||||||||||||||
| NTMWDPC-003 | CRN000017 | In Service | Overhead | Blower Bldg. | Panther Creek WWTP | BRIDGE | 0 to 10 ton | ACE GAFFEY | 5 ton | UHSG | ELECTRIC | BLACK BEAR | TUDH-500 | 700059 | 5 ton | WIRE ROPE | ELECTRIC | ||||||||||||||||||||||||||||||||
| NTMWDPC-005 | CRN000019 | In Service | Winch Derrick | Headworks Bldg. | Panther Creek WWTP | 0 to 10 ton | THERN | 572M1 | 5007-37594 | 2200 lbs | JIB | ||||||||||||||||||||||||||||||||||||||
| NTMWDPC-006 | CRN000020 | In Service | Winch Derrick | Primary Clarifier | Panther Creek WWTP | WINCH/DERRICK | 0 to 10 ton | THERN | 5110M3SS-S7 | 5009-51103 | JIB | ||||||||||||||||||||||||||||||||||||||
| WWTPSC-002 | CRN000021 | In Service | Overhead | Plant 1, Blower Room, Operating Bldg | Sabine Creek WWTP | - | BRIDGE | 0 to 10 ton | ACE GAFFEY | 4 ton | TRSG | MANUAL | - | - | - | - | - | - | COFFING | AT.103.KC.2 | 4 ton | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||||||
| WWTPSM-001 | CRN000023 | In Service | Overhead | Blower bldg 2 | South Mesquite Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | - | 6860 | 4 ton | UHSG | MANUAL | - | - | - | - | 20 | 75 | na | na | na | 2 | - | - | CHESTER | Zephyr | AG-8831 | 4 ton | 18' | CHAIN | MANUAL | - | - | - | - | CHESTER | ||||||||||||
| WWTPRC-003 | CRN000024 | In Service | Overhead | Blower bldg | Rowlet Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACE GAFFEY | 98-2060-2 | 5 ton | UHSG | CHAIN/GEAR | - | - | - | - | SHAWBOX | MDT06 | 98J01706M | 5 TON | WIRE ROPE | ELECTRIC | Disc | 460 | THREE | |||||||||||||||||||||||
| wwtpsm-006 | crn000025 | In Service | Overhead | maintenance shop | South Mesquite Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACECO | 1110 | 2 ton | UHSG | MANUAL | 18' | 40' | 2 | |||||||||||||||||||||||||||||||||
| NTMWDTWT-001 | CRN000030 | In Service | Overhead | Intermediate HSPS | Tawakoni water treatment plant WTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 34678805 | 15 ton | TRDG | ELECTRIC | - | 480 | THREE | - | 48 | 140 | - | - | DETROIT | 152230 | 15 ton | WIRE ROPE | - | - | 480 | THREE | 2 | - | ||||||||||||||||||
| NTMWDCPS-001 | CRN000031 | In Service | Overhead | Conveyance Pump Bldg East Fork RWS Conveyance PS | Conveyance PS East Fork RWS | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 3408631 | 50ton | TRDG | ELECTRIC | - | 480 | THREE | - | 2 | - | - | DETROIT | 151699 | 50 ton | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | DETROIT | |||||||||||||||||||
| NTMWD Diversion PS East Fork RWS 0001 | CRN000032 | In Service | Overhead | Diversion Pump bldg East Fork RWS Diversion PS | Diversion PS East Fork RWS | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | - | 20 ton | TRDG | ELECTRIC | - | - | - | - | 2. right hand left hand lay | - | - | R&M | SX50820200P54FHD0S | HHY52578 | 20ton | 25' | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | - | ||||||||||||||||||
| NTMWD-WyliePL2-002 | CRN000033 | In Service | Overhead | 401-S Technical Services Bay 2 | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | PROSERV | A5596B | 7.5 t | TRSG | ELECTRIC | lifttech | 2 | 480 | THREE | 2 | 38'8" | 80 | 1 | - | - | SHAWBOX | WC3M-25 | 06H14E774 | 7.5t | 17' | WIRE ROPE | ELECTRIC | Disc | 480 | - | 2 | SHAWBOX | ||||||||||||||
| NTMWD-WyliePL2-003 | CRN000034 | In Service | Overhead | Technical Services WeldShop | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | PROSERV | A5852 | 7.5 ton | TRSG | ELECTRIC | lifttech | 2 | 480 | THREE | 2 | 80 | 1 | - | - | SHAWBOX | WC3M-25 | 06H14F772 | 7.5 t | 17 | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | LIFT TECH | |||||||||||||||
| NTWMD-WyliePL2-004 | CRN000036 | In Service | Overhead | Technical Services Warehouse BLDG W | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | PROSERV | A5598 | 7.5 t | TRSG | ELECTRIC | lifttech | 2 | 480 | THREE | 2 | 60 | 1 12 mm 118' rope length | - | - | SHAWBOX | WC3M-25 | 06H14F773 | 7.5 ton | 17' | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | - | |||||||||||||||
| NTMWD-WyliePL2-005 | CRN000036 | In Service | Overhead | Technical Services Warehouse BLDG X | Wylie Water Plant 2 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | A. HANDLING | 22855 | 7.5 t | UHDG | ELECTRIC | 2 | 480 | THREE | - | - | - | R&M | SX50410080P56FDL0S | 58621165 | 7.5 | 16". 11mm 44m left hand rope | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | - | ||||||||||||||||||
| NTMWD-WylieRawPS3-001 | CRN000037 | In Service | Overhead | 1321-C | Wylie Raw Water PS3 | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | OSBORN | na | 30 t | TRDG | ELECTRIC | - | 460 | THREE | 2 | - | - | R&M | D11-30-29 | 1698729401 | 30t | WIRE ROPE | ELECTRIC | Disc | 480 | THREE | 2 | - | |||||||||||||||||||
| NTMWD-CoRoyse-001 | CRN000039 | In Service | Overhead | Pump Station 2 | City of Royse City PS2 | - | MONORAIL | 0 to 10 ton | COFFING | 2.114.h.vv | 2 ton | MONORAIL | - | - | - | - | - | - | - | COFFING | 2.114.H.VV | 2 ton | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||||
| NTMWDTRW-001 | CRN000040 | In Service | Overhead | Texoma raw water pump station | Texoma Raw Water PS | Production/General Maintenance 24 hours or more | BRIDGE | 51 to 100 ton | OSBORN | 87169 | 65 ton | TRDG | ELECTRIC | - | 480 | THREE | - | 64' | 100 | na | na | na | 1 | na | - | - | OSBORN | 65 ton | 60 | WIRE ROPE | ELECTRIC | Shoe | 480 | THREE | 2 | rotary | OSBORN | ||||||||||||
| NTMWD-WyliePL3-008 | CRN000041 | In Service | Overhead | . | Wylie Water Plant 3 | - | BRIDGE | 11 to 50 ton | KONE | A16979 | 8160042 | 25 ton | TRDG | ELECTRIC | - | - | - | - | - | - | KONE | XL512N40GDC420A0ES | 305141 | 25 ston | WIRE ROPE | ELECTRIC | - | - | - | - | - | ||||||||||||||||||
| NTMWDLTRW-001 | CRN000042 | In Service | Overhead | Pump station | Lake tawakoni raw water PS | Production/General Maintenance 24 hours or more | BRIDGE | 11 to 50 ton | ACE GAFFEY | 34678801 | 25 ton | TRDG | - | 4 | - | - | - | - | - | YALE | FEW25-82TR9/3D4 | 07F28K42 | 25 ton | WIRE ROPE | ELECTRIC | - | - | - | - | - | |||||||||||||||||||
| NTMWD-CoFate-001 | CRN000043 | In Service | Overhead | Pump Station | City of Fate Meter | - | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||||||||||||||||||||||||
| NTMWD-PlanoPS3-001 | CRN000044 | In Service | Overhead | #3 | City Of Plano PS3 | - | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | BUDGIT | USA01 | 12AU027 | 1 ton | CHAIN | MANUAL | - | - | - | - | - | |||||||||||||||||||||
| NTMWDPLANO-004 | CRN000045 | In Service | Overhead | WA3557 | City of Plano PS4 | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | - | - | - | - | - | - | - | - | BUDGIT | USA01 | USA1622WN | 1 ton | CHAIN | - | - | - | - | - | - | |||||||||||||||||||||
| NTMWD-WyliePL1-001 | CRN000050 | In Service | Overhead | 810-B HSPS1-1 | Wylie Water Plant 1 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | KONE | K13007 | 20000lbs | UHSG | ELECTRIC | mf06LA100-131F81001EIP55 | 2 | 4560 | 480 | - | 2 | 46'9" | 94' | n/a | 1 | - | - | KONE | CXT5040100P55FDLOS | 10184908 | 10Ton | 28' | WIRE ROPE | ELECTRIC | Other | 19A | 480 | THREE | 2 | geared | - | ||||||||||
| ntmwd 1A PS | CRN000051 | In Service | Small Hoist | WA3579-A 965 E. Brown st | City Of Wylie 1A PS | Production/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 205 | 790167 | 10000lbs | MONORAIL | MANUAL | - | - | HARRINGTON | 205 | 790167 | 5ton | 25 | CHAIN | MANUAL | ||||||||||||||||||||||||||
| ntmwdcasaview ps-001 | CRN000052 | In Service | Small Hoist | ntmwd Mesquite | casa view WA-3583 | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | No Tag | MONORAIL | NONE | - | YALE | 2 ton | CHAIN | MANUAL | - | YALE | ||||||||||||||||||||||||||||||
| NTMWD-MBPS-002 | CRN000054 | In Service | Overhead | 201 FM 544 Murphy Texas | Murphy Booster PS | Stand By Maintenance/General Maintenance 24 hours or more | MONORAIL | 0 to 10 ton | - | 3 t | MONORAIL | MANUAL | - | - | - | - | 57 | 1 | - | - | BUDGIT | 303122 | 3317 catalog number | 3t | 12' | CHAIN | MANUAL | Disc | - | - | - | BUDGIT | |||||||||||||||||
| NTMWD-WyliePL1-002 | CRN000055 | In Service | Overhead | F5, Paint/Carpentry Shop 810E | Wylie Water Plant 1 | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | PROSERV | A5600 | 5t | TRSG | MANUAL | - | - | - | - | - | - | BUDGIT | USA 05 | 06HU021 | 5t | 15 ft | CHAIN | MANUAL | Disc | - | - | - | LIFT TECH | HGC06B | |||||||||||||||||
| NTMWD-WC036 | CRN000056 | In Service | Overhead | Disk Filters (LOC 06) | Wilson Creek WWTP | Production/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | A11621 | 1.5 ton | UHSG | MANUAL | - | - | - | - | 120 | BUDGIT | USA15 | USA1583WY | 1.5 ton | CHAIN | MANUAL | - | - | ||||||||||||||||||||||||
| WWTPMC-001 | CRN00026 | In Service | Overhead | UV BUILDING | MUDDY CREEK | - | BRIDGE | 0 to 10 ton | ACE GAFFEY | 27830701 | 1 TON | UHSG | MANUAL | - | - | - | - | - | - | COFFING | C6117NZ88A | 1614100 | 1 TON | CHAIN | MANUAL | Disc | 460 | - | - | - | |||||||||||||||||||
| WWTPSM-005 | CRN22 | In Service | Overhead | Blower bldg 1 | South Mesquite Creek WWTP | Stand By Maintenance/General Maintenance 24 hours or more | BRIDGE | 0 to 10 ton | ACECO | 1109 | 2 ton | UHSG | MANUAL | - | - | - | - | WRIGHT | 08 | unk | 2 ton | 15 | CHAIN | MANUAL | |||||||||||||||||||||||||
| WWTPUR-002 | HO1000008 | In Service | Overhead | Upper Rowlette Creek Lift Station | Rowlet Creek WWTP | - | BRIDGE | 0 to 10 ton | ACE GAFFEY | 1359 | 7.5 ton | UHSG | MANUAL | - | - | - | - | - | - | BEEBE | 12-86-1 | C3H080 | CHAIN | MANUAL | - | - | - | - | - | ||||||||||||||||||||
| NTMWDPC-002 | HO1000024 | In Service | Small Hoist | RAS Bldg. | Panther Creek WWTP | MONORAIL | 0 to 10 ton | BUDGIT | USA02 | 07FU079 | 2 ton | CHAIN | MANUAL | ||||||||||||||||||||||||||||||||||||
| NTMWDPC | Out of Service | Winch Derrick | Tech to change | Tech to change | |||||||||||||||||||||||||||||||||||||||||||||
| WWTPSQUAB-002 | HO100036 | In Service | Winch Derrick | RAS Building | Squabble Creek WWTP | Production/General Maintenance 24 hours or more | WINCH/DERRICK | 0 to 10 ton | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |