2-2026-ITN-0001-BL Exhibit B LaundryUnit Distribution.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- Residential Student Housing Laundry Services
- Solicitation number
- 2026-ITN-0001-BL
- Issued by
- Palm Beach County, Florida
About this file
This file is an exhibit detailing laundry unit distribution for Florida Atlantic University's residential housing facilities across its Boca Raton and Jupiter campuses. The distribution list specifies equipment placement across multiple residential communities, including community laundry rooms, student apartments, and pro-staff housing units. Community laundry rooms are distributed across 19 buildings with varying capacities ranging from single units to 18 front-load washers per location, with dryer configurations including both individual and stacked units. The document lists 371 student apartments across four buildings (IVAS, IVAN) with predominantly top-load washers and electric stackable dryers, and 19 pro-staff apartments distributed across multiple facilities with primarily single washer-dryer combinations. Total equipment inventory includes 120 front-load washers, 32 top-load washers, and 146 dryers distributed across all residential locations. Gas-powered dryers are utilized in community laundry facilities, while electric dryers are standard in student and pro-staff housing units.
The exhibit provides detailed specifications regarding dryer configurations, including notes on separate versus stacked units and facility constraints such as closet space limitations in student apartments. The file indicates that current student apartment closets support only top-loading washers with stacked dryers, establishing baseline equipment requirements for the laundry services contract. Equipment distribution reflects differentiated needs across facility types, with larger community laundry rooms featuring commercial-scale equipment and individual housing units equipped with compact stackable units. This comprehensive inventory list serves as the basis for determining lease quantities, maintenance schedules, and service call requirements for the university's laundry services procurement.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Community Laundry Rooms
| Building | Tower/Wing | Floor | Room # | Front-Load W | Top-Load W | Dryer | Dryer Gas/Elec | Notes |
| APT | N/A | 1 | 119B | 1 | 1 | 2 | Gas | |
| APT | N/A | 2 | 213 | 1 | 2 | 2 | Gas | |
| APT | N/A | 3 | 313 | 1 | 2 | 2 | Gas | |
| APT | N/A | 4 | 413 | 1 | 2 | 2 | Gas | |
| APT | N/A | 5 | 513 | 1 | 2 | 2 | Gas | |
| APT | N/A | 6 | 613 | 1 | 2 | 2 | Gas | |
| APT | N/A | 7 | 713 | 1 | 2 | 2 | Gas | |
| GPT | North | 1 | 125 | 10 | 0 | 10 | Gas | Dryers are 2 stack units |
| GPT | South | 1 | 165 | 10 | 0 | 10 | Gas | Dryers are 2 stack units |
| HPT | North | 1 | 126 | 10 | 0 | 10 | Gas | Dryers are 2 stack units |
| HPT | South | 1 | 166 | 10 | 0 | 10 | Gas | Dryers are 2 stack units |
| IRT | East | 2 | 229 | 8 | 0 | 8 | Gas | Dryers are 2 stack units |
| IRT | West | 2 | 266 | 8 | 0 | 8 | Gas | Dryers are 2 stack units |
| PAR | N/A | 1 | 116 | 18 | 0 | 18 | Gas | Separate washer and dryer |
| RH1 | Guest Housing | 1 | 110 | 1 | 0 | 1 | Elec | Separate washer and dryer |
| RH1 | N/A | 2 | 223 | 6 | 0 | 5 | Elec | 5 stacked units; one lone front load washer |
| RH2 | N/A | 2 | 223 | 6 | 0 | 6 | Elec | 6 stacked units |
| RH3 | N/A | 1 | 121 | 1 | 1 | 2 | Elec | Dryers stacked; washer alone |
| RH3 | Guest Housing | 1 | 120 | 1 | 0 | 1 | Elec | Separate washer and dryer |
| RH3 | N/A | 2 | 211 | 1 | 1 | 2 | Elec | Dryers stacked; washer alone |
| RH3 | N/A | 3 | 311 | 1 | 1 | 2 | Elec | Dryers stacked; washer alone |
| TAL | N/A | 3 | 301 | 2 | 5 | 8 | Gas | Dryers are 2 stack units |
| TAL | N/A | 5 | 501 | 2 | 5 | 8 | Gas | Dryers are 2 stack units |
| TAL | N/A | 7 | 701 | 2 | 5 | 8 | Gas | Dryers are 2 stack units |
| UVA | 57 | 1 | 121 | 3 | 0 | 2 | Elec | Separate washer and dryer, not stacked |
| UVA | 58 | 2 | 201 | 5 | 0 | 4 | Elec | Separate washer and dryer, not stacked |
| UVA | 59 | 2 | 201 | 4 | 0 | 4 | Elec | Separate washer and dryer, not stacked |
| UVA | 60 | 2 | 201 | 4 | 0 | 4 | Elec | Separate washer and dryer, not stacked |
| BPW | N/A | 1 | 123 | 0 | 1 | 1 | Elec | Single unit side-by-side |
| 120 | 32 | 146 |
Student Apartments
| Building | Apt Type | Qty | Dryer Elec/Gas | Stackable Y/N | Notes |
| IVAS | 4 BR | 148 | Elec | Yes | Current closet only supports top loading washer with stacked dryer |
| IVAS | 1 BR | 7 | Elec | Yes | Current closet only supports top loading washer with stacked dryer |
| IVAN | 4 BR | 90 | Elec | Yes | Current closet only supports top loading washer with stacked dryer |
| IVAN | 2 BR | 119 | Elec | Yes | Current closet only supports top loading washer with stacked dryer |
| IVAN | 1 BR | 7 | Elec | Yes | Current closet only supports top loading washer with stacked dryer |
| 371 |
Pro-Staff Apartments
| Building | Tower/Wing | Floor | Room # | Front-Load W | Top-Load W | Dryer | Dryer Gas/Elec | Stacked Y/N | Notes |
| Bldg 18 | N/A | 1 | N/A | 0 | 1 | 1 | Elec | No | |
| GPT | North | 1 | 129 | 0 | 1 | 1 | Elec | Yes | |
| GPT | South | 1 | 169 | 0 | 1 | 1 | Elec | Yes | |
| HPT | N/A | 1 | 113 | 0 | 1 | 1 | Elec | Yes | |
| HPT | North | 1 | 129 | 0 | 1 | 1 | Elec | Yes | |
| HPT | South | 1 | 169 | 0 | 1 | 1 | Elec | Yes | |
| IRT | East | 1 | 125 | 0 | 1 | 1 | Elec | Yes | |
| IRT | West | 1 | 163 | 0 | 1 | 1 | Elec | Yes | |
| IVAN | N/A | 1 | 126 | 0 | 1 | 1 | Elec | Yes | |
| IVAN | N/A | 1 | 128 | 0 | 1 | 1 | Elec | Yes | |
| IVAS | N/A | 1 | 128 | 0 | 1 | 1 | Elec | Yes | |
| IVAS | N/A | 1 | 130 | 0 | 1 | 1 | Elec | Yes | |
| PAR | N/A | 1 | 124 | 1 | 0 | 1 | Elec | No | |
| PAR | N/A | 1 | 134 | 1 | 0 | 1 | Elec | No | |
| PAR | N/A | 1 | 137 | 1 | 0 | 1 | Elec | No | |
| RH2 | N/A | 1 | 101 | 0 | 1 | 1 | Elec | Yes | |
| TAL | South | 1 | 141 | 0 | 1 | 1 | Elec | Yes | |
| TAL | South | 1 | 142 | 1 | 0 | 1 | Elec | No | ADA accessible |
| UVA | N/A | 1 | 57A-103 | 1 | 0 | 1 | Elec | Yes | |
| 5 | 14 | 19 |
File details come from the government source that posted it. Updated .