2-2- Exhibit A – Minimum Standards for Responsiveness.pdf
PDF 317 KB Posted
- Solicitation number
- SLCo ART123092 Larry H. and Gail Miller Arts Center- Stage 1 General Contractor- RFQ
- Issued by
- Salt Lake County, Utah
About this file
This document is a Minimum Standards for Responsiveness form from Salt Lake County for the Large Project involving the Larry H. and Gail Miller Arts Center Construction. The form is designed to pre-qualify potential construction contractors by requiring them to answer 11 specific performance-related questions across three categories: Contract Specific Performance, Project Specific Performance, and LEED Specific Performance. Proposers must answer all questions affirmatively or their bid will be considered non-responsive and non-responsible.
The questionnaire focuses on evaluating a contractor's past performance, including their ability to complete construction projects without issues such as surety calls, contract defaults, or liquidated damages. It also assesses the contractor's experience with projects of similar size and scope, ability to provide references, safety record, scheduling capabilities, and experience with specialty subcontractors. Additionally, the form inquires about the contractor's LEED certification experience and commitment to third-party building and envelope commissioning. The document must be included in the bid package, and the County reserves the right to investigate the responses further.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Proposer must answer, in the affirmative, to all questions below or the Proposer's bid will be deemed non-responsive and non-responsible.
Blank Page
| EXHIBIT: [EXHIBIT A] |
| STANDARD: MINIMUM STANDARDS FOR RESPONSIVENESS |
| CONST: CONSTRUCTION SERVICES FOR: |
| ID: CFA_0001SW |
| OWNER: SALT LAKE COUNTY - LARGE PROJECT |
| NO: NO |
| 01: 01 |
| 02: 02 |
| 03: 03 |
| 04: 04 |
| 05: 05 |
| Check Box 04b: Off |
| 06: 06 |
| 07: 07 |
| CONTRACTOR: |
| TITLE: |
| COMPANY: |
| COMPANY TEXT: COMPANY NAME |
| SIGNOR TEXT: SIGNER |
| TITLE TEXT: TITLE |
| PROJ TEXT: PROJ. ID. |
| QUESTION 02: Completed all construction projects without being removed from the project upon a claim by the Owner for default or breach of contract? |
| QUESTION 03: Completed all construction projects without assessment or payment of Liquidated Damages? |
| QUESTION 04: In the last five years, has your firm, acting as the General Contractor, worked on a project of similar size and scope? |
| QUESTION 05: From the last 5 years, is your firm able to provide a minimum of 3 references who will speak to your performance? |
| QUESTION 06: In the last five years has your firm, acting as General Contractor, had any recordable safety incidents? |
| QUESTION 07: In the past five years, as the General Contractor, have you successfully completed all comparable projects within the contracted schedule? |
| QUESTION 08: Does your firm have experience working with specialty subcontractors for acoustics, stage rigging, theatrical lighting, and audiovisual systems? |
| QUESTION 09: In the last five years, has your firm, acting as the General Contractor, completed a project which is LEED© certified, or is in process of completing a project registered with the USGBC anticipating LEED© certification? |
| QUESTION 10: Does one or more members of your team have LEED© certification experience or is a LEED© Accredited Professional? |
| QUESTION 11: Will your firm and your sub-contractors support third-party building and envelope commissioning, including LEED© commissioning requirements? |
| 08: 08 |
| 09: 09 |
| CHECK 09A: Off |
| CHECK 09B: Off |
| CHECK 08A: Off |
| CHECK 08B: Off |
| CHECK 07A: Off |
| CHECK 07B: Off |
| CHECK 06A: Off |
| CHECK 06B: Off |
| CHECK 05A: Off |
| CHECK 05B: Off |
| CHECK 04A: Off |
| CHECK 03A: Off |
| CHECK 03B: Off |
| CHECK 02A: Off |
| CHECK 02B: Off |
| CHECK 01A: Off |
| CHECK 01B: Off |
| 10: 10 |
| CHECK 10A: Off |
| CHECK 10B: Off |
| 11: 11 |
| CHECK 11A: Off |
| CHECK 11B: Off |
| YES: YES |
| QUESTIONS: QUESTIONS |
| CONTRACT 01: In the last five years, has your firm, acting as the General Contractor: |
| QUESTION 01: Completed all construction projects without the owner(s) calling in or involving sureties to assist in completing or assuming responsibility for completing a project? |
| CONTRACT: CONTRACT SPECIFIC PERFORMANCE: |
| PROJECT: The Larry H. and Gail Miller Arts Center Construction |
| LEED: LEED SPECIFIC PERFORMANCE: |
| PROJ PERF: PROJECT SPECIFIC PERFORMANCE: |
| Text2: This form must be included in your bid package as part of the required forms for submittal. |
The County reserves the right to investigate further, any of the responses to the above questions.
File details come from the government source that posted it. Updated .