2-2-CS27008-27056210-Approved Plans.pdf
PDF 23 MB Posted
- Solicitation number
- CS27008
- Issued by
- Utah
About this file
This document contains approved plans for a construction project issued by the Utah Division of Facilities Construction and Management (DFCM) for Bridgerland Technical College's Main Campus. The project scope encompasses painting the west facade, walls, trim, and overhead doors; adding a numbering system to all overhead doors; and an additive alternate for the northwest wall. This is a restricted invitational procurement limited to four pre-qualified contractors: Accent Painting, Brush Brothers Painting, Nicholls Brothers Painting, and Pecks Painting. A mandatory site meeting is scheduled for July 28, 2026, at 3:00 p.m., with attendance required to submit a bid. Bids are due August 11, 2026, via the U3P website. Questions must be submitted by July 30, 2026, at 3:00 p.m., with an addenda deadline of August 3, 2026, at 3:00 p.m. Subcontractor lists are due August 12, 2026, at 3:00 p.m. The construction cost estimate is $149,999.00, with substantial completion required by December 31, 2026. Liquidated damages of $100 per day apply for delays beyond the completion date.
All contractors must hold current Utah state licensure and submit a DFCM Subcontractors List Form and a bid bond of 5% with their bids on AIA Document A310-2010 form or equivalent. DFCM will award a Short Form Construction Contract to the lowest responsive and responsible bidder, with bid tabulation published within 24 hours of the deadline. The project is tax-exempt, and all bidders must certify non-debarment and non-restriction as foreign entities. Award and contract execution will follow immediately after bid tabulation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-CS27008-27056210-Approved Plans.pdf | ||
| 1-CS27008-27056210-Solicitation.pdf | ||
| 1-1-CS27008-27056210-Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BTECH - MAIN CAMPUS WEST FAÇADE AND DOORS IMPROVEMENTS
DFCM Project 27056210
June 29, 2026
Objective: Paint exterior west façade of BTECH Main Campus
Project Location: 1301 N 600 W Logan, UT 84321
Project Description
The west façade walls of the BTECH Main Campus which consist of metal, stucco, brick, and CMU shall be painted to match the beige color at the southwest corner at the Intech Campus portion of the building. The trim at the roofline and around the overhead doors shall be painted to match the black color and sheen that already exists on much of the trim. Corner trim on the walls can be painted to match the walls. The man doors are to remain painted gray as they are. The overhead doors shall be painted white and each shall be assigned a number. The numbers shall be approximately 14” in height with black numbers on a white background. Contractor has the option of removing the signs and painting the numbers on the doors, or adding new placards to the doors with numbers. There are a few locations where minor stucco repair is needed. There is prep work to be done including peeling paint on some of the overhead doors. Thoroughly sand and remove all loose paint and foreign material.
The contractor shall not paint windows, cameras, fire alarms, roof drain openings, light fixtures, exhaust fans, electrical meters, electrical gear, and signage. The contractor is responsible for cleanup and prevention of all overspray, dust, paint chips or any other damage or problems created by the preparation and painting of the project. There will be an add alternate to paint the northwest wall as shown in the photos. Please include the add alternate as a separate line item on the bid.
Paint Specifications
Corrugated metal and stucco to be painted with 2 coats of “Duration Exterior Acrylic Satin” or of equal or better quality paint matching the beige color at the southwest corner of the building (see the attached Sherwin Williams specification).
Trim at roofline to be painted with 2 coats of “Duration Exterior Acrylic” or of equal or better quality paint matching the black color and sheen existing on much of the building. (see the attached Sherwin Williams specification).
Brick and split face CMU to be painted with 1 coat of “Loxon Acrylic Block Surfacer” and then 2 coats of “Duration Exterior Acrylic” or of equal or better quality paint matching the beige color at the southwest corner of the building (see the attached Sherwin Williams specification).
Overhead Door Frames to be painted with 2 coats of “Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss” or of equal or better quality paint matching the black color and sheen existing on much of the building. (see the attached Sherwin Williams specification).
Overhead Doors to be painted with 2 coats of “Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss” or of equal or better quality paint and to be white. (see the attached Sherwin Williams specification).
Man doors and frames to remain existing gray.
102.14B
Duration® Exterior Acrylic Satin K33-Series
3/2026 www.sherwin-williams.com continued on back
CHARACTERISTICS
Duration® Exterior Latex Coating is the result of advances in acrylic technology. Duration uses PermaLast® technology to provide you with the most durable and longest lasting coating available for protecting the outside of your home.
VinylSafe™ paint colors allow you the freedom to choose from 100 color options, including a limited selection of darker colors formulated to resist warping or buckling when applied to a sound, stable vinyl substrate.
• Self-priming One Coat Protection
• Low temperature application down to 35° F.
• Easy application
• Excellent durability and hiding
• Resists Blistering and Peeling
Color: Most Colors
Coverage: 250-300 sq. ft. per gallon @ 5.3-6.4 mils wet, 2.0-2.4 mils dry, up to 7.0 mils wet: 2.7 mils dry
Drying Time, @ 50% RH:
@35-45°F @45°F+ Touch: 2 Hours 1 Hour Recoat: 24-48 Hours 4 Hours Drying and recoat times are temperature, humidity, and film thickness dependent.
Finish: 10-20 units @ 60°
Tinting with CCE only:
Base: oz. per Strength gallon Ultrawhite 0-6 SherColor Extra White 0-7 SherColor Deep Base 4-14 SherColor Ultradeep Base 10-14 SherColor Light Yellow 4-14 SherColor
Extra White K33W00251 (may vary by color)
V.O.C.(less exempt solvents):
Less than 50 grams per litre; 0.42 lbs. per gallon
As per 40 CFR 59.406 Volume Solids: 38 ±2% Weight Solids: 50 ±2% Weight per Gallon: 10.28 lbs Flash Point: N.A.
Vehicle Type: Acrylic Shelf Life: 36 months, unopened WVP Perms (US): 18.66 grains/(hr ft2 in Hg)
Mildew Resistant This coating contains agents which inhibit the growth of mildew on the surface of this coating film.
COMPLIANCE
As of 03/02/2026, Complies with :
OTC Yes OTC Phase II Yes S.C.A.Q.M.D. Yes CARB Yes CARBSCM 2007 Yes CARB SCM 2020 Yes Canada Yes LEED® v4 & v4.1 Emissions N/A LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified Yes MIR-Manufacturer Inventory Yes
MPI® #15, 315
APPLICATION
When the air temperature is at 35°F (1.7°C), substrates may be colder; prior to painting, check to be sure the air, surface, and material temperature are above 35°F (1.7°C) and at least 5° above the dew point. Avoid using if rain or snow is expected within 2-3 hours.
Do not apply at air or surface temperatures below 35°F (1.7°C) or when air or surface temperatures may drop below 35°F (1.7°C) within 48 hours.
No reduction needed.
Brush:
Use a nylon-polyester brush such as Purdy® Pro-Extra.
Roller:
Use a high quality 3/8-3/4 inch nap synthetic roller cover such as Purdy® Marathon®
For additional specific brushes and roller cover recommendations, please refer to our Brush and Roller Guide on the Sherwin-Williams website.
Spray - Airless:
Pressure 2000 p.s.i.
Tip .015-.019 inch
APPLICATION TIPS
Make sure product is completely agitated (mechanically or manually) before use.
Thoroughly follow the recommended surface preparations. Most coating failures are due to inadequate surface preparation or application.
Thorough surface preparation will help provide long term protection with Duration coating. On repaint work, apply one coat of Duration coating:
on bare surfaces, apply two coats of Duration, allowing 4 hours drying between coats.
Do not paint in direct sun. Apply at temperatures above 35°F. During application at temperatures above 80°F, Duration sets up quickly. Some adjustment in your painting approach may be required. Paint from a dry area into the adjoining wet coating area. Dries to touch in 1 hour and is ready for service overnight.
On large expanses of metal siding, the air, surface, and material temperatures must be 50°F or higher.
SPECIFICATIONS
Duration Exterior Acrylic Latex is self-priming on most surfaces. Apply 2 coats on new, bare substrates or 1 coat for repaint.
Use on these properly prepared surfaces:
Aluminum & Aluminum Siding1
Galvanized Steel1
Concrete Block Split face Block Cement Composition Siding/Panels Stucco Concrete Plywood Wood *Vinyl Siding
Surfaces with a pH greater than 9 must be primed with a high pH-resistant coating such as Loxon Concrete & Masonry Primer.
Standard latex primers cannot be used below 50°F. See specific primer label for that product’s application limitations.
Concrete masonry units (CMU) - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating.
Knots and some woods, such as redwood and cedar, contain a high amount of tannin, a colored wood extract. If applied to these bare woods, the first coat of DURATION may show some staining, but it will be trapped in the first coat. A second coat will uniform the appearance. If staining persists, spot prime severe areas with 1 coat of Exterior Oil-Based Wood Primer prior to using
DURATION.
1 On large expanses of metal siding, the air, surface, and material temperatures must be 50°F (10°C) or higher.
Duration® Exterior Acrylic Satin
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS
SURFACE PREPARATION
WARNING! If you scrape, sand or remove old paint, you may release lead dust. LEAD IS TOXIC.
EXPOSURE TO LEAD DUST CAN CAUSE
SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE,
ESPECIALLY IN CHILDREN. PREGNANT WOMEN
SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH-approved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Information Hotline at 1-800-424- LEAD or log on to www.epa.gov/lead.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Existing peeled or checked paint should be scraped and sanded to a sound surface. Glossy surfaces should be sanded dull. Stains from water, smoke, ink, pencil, grease, etc. should be sealed with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Aluminum and Galvanized Steel:
Wash to remove any oil, grease, or other surface contamination. All corrosion must be removed with sandpaper, wire brush, or other abrading method.
Cement Composition Siding/Panels:
Remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, and peeling or defective coatings. Allow the surface to dry thoroughly. If the surface is new, test it for pH, if the pH is higher than 9, prime with Loxon Concrete & Masonry Primer. After power washing, previously painted masonry may still have a powdery surface that should be sealed with Loxon Conditioner and then apply 1 coat of Duration.
Caulking:
Gaps between windows, doors, trim, and other through-wall openings can be filled with the appropriate caulk after priming the surface. Allow proper drying tine before application of the finish.
Concrete, Masonry, Cement, Block:
All new surfaces must be cured according to the supplier’s recommendations—usually about 30 days.
Remove all form release and curing agents. Rough surfaces should be filled to provide a smooth surface. If painting cannot wait 30 days, allow the surface to cure 7 days and prime the surface with Loxon Concrete & Masonry Primer. Cracks, voids, and other holes should be repaired with an elastomeric patch or sealant.
Concrete masonry units (CMU):
Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating.
Composition Board/Hardboard:
Because of the potential for wax bleeding out of the substrate, apply 1 coat of Exterior Oil-Based Wood Primer and then topcoat.
Stucco:
Remove any loose stucco, efflorescence, or laitance.
Allow new stucco to cure at least 30 days before painting. If painting cannot wait 30 days, allow the surface to dry 7 days and prime with Loxon Concrete & Masonry Primer. Repair cracks, voids, and other holes with an elastomeric patch or sealant.
SURFACE PREPARATION
Clean mildew from the Surface: Mildew is a fungus that looks like dirt but won’t wash off. Mildew must be removed before painting, or it will grow through any new coat of paint. To remove mildew or suspected mildew, scrub surface before painting with a commercial mildew remover following manufacturer’s safety instructions.
Previously Painted Surfaces:
Spot prime bare areas with Duration, wait 4 hours, and paint the entire surface. Some specific surfaces require specialized treatment.
Steel:
Rust and mill scale must be removed using sandpaper, wire brush, or other abrading method.
Bare steel must be primed with a corrosion resistant primer such as All Surface Enamel Primer the same day as cleaned.
Unpainted Surfaces:
Duration can be used as a self-priming coating on many bare surfaces. When used this way, the first coat of Duration acts like a coat of primer and the second coat provides the final appearance and performance.
*Vinyl or other PVC Building Products:
Clean the surface thoroughly by scrubbing with warm, soapy water. Rinse thoroughly. If needed prime with appropriate white primer. Do not paint vinyl with any color darker than the original color or having a Light Reflective Value (LRV) of less than 56 unless VinylSafe® Colors are used. If VinylSafe colors are not used the vinyl may warp. Follow all painting guidelines of the vinyl manufacturer when painting. Only paint properly installed vinyl siding.
Deviating from the manufacturer’s painting guidelines may cause the warranty to be voided.
Wood, Plywood, Composition Board:
Sand any exposed wood to a fresh surface. Patch all holes and imperfections with a wood filler or putty and sand smooth. All patched areas must be primed.
Knots and some woods, such as redwood and cedar, contain a high amount of tannin, a colored wood extract.
If applied to these bare woods, the first coat of Duration may show some staining, but it will be trapped in the first coat. A second coat will uniform the appearance. If staining persists, spot prime severe areas with 1 coat of Exterior Oil-Based Wood Primer prior to using Duration.
CAUTIONS
For exterior use only.
Protect from freezing.
Non-Photochemically reactive.
Not for use on floors
Before using, carefully read CAUTIONS on label.
ZINC: Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Avoid contact with eyes and skin. Wash hands after using. Keep container closed when not in use. Do not transfer contents to other containers for storage.
FIRST AID: In case of eye contact, flush thoroughly with large amounts of water. Get medical attention if irritation persists. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately.
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. DO NOT TAKE
INTERNALLY. KEEP OUT OF THE REACH OF
CHILDREN.
HOTW 03/02/2026 K33W00251 45 35
SP, FR
CLEANUP INFORMATION
Clean spills, spatters, hands, and tools immediately after use with soap and warm clean water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
http://www.paintdocs.com/
115.01
Loxon® Acrylic Block Surfacer LX01W0200 White
CHARACTERISTICS
Loxon Acrylic Block Surfacer is a lightweight technology, 100% acrylic resin surfacer for interior and exterior poured and precast concrete, concrete block, cinder block, and stucco. It is designed to smooth and uniform surfaces, helping to reduce pinholes.
Loxon Acrylic Block Surfacer’s technology solves problems:
Faster production rates Excellent filling and sealing properties Suitable for use in USDA-inspected facilities Topcoat with high performance coatings such as epoxies and urethanes Alkali resistant from 8 to 13 pH Use at temperatures down to 35°F
Color: White Coverage:
Wet mils: 16 Dry mils: 8.8 Coverage sq.ft. per gallon 50-100 Drying Schedule @ 50% RH, 16 mils wet:
temperature and humidity dependent
@35-55°F @ 55°F+ Touch: 2 hours 1 hour Recoat:
with latex: 24 hours 8 hours with alkyd: 48 hours 48 hours with high performance: 48 hours 48 hours Air and surface temperatures must not drop below 35°F for 48 hours after application.
Finish: Flat
Tinting with CCE only:
Base oz.per gallon Strength
White 0-2 SherColor
White LX01W0200 V.O.C. (less exempt solvents):
86 grams per litre; 0.72 lbs. per gallon As per 40 CFR 59.406
Volume Solids: 55 ± 2% Weight Solids: 60 ± 2% Weight per Gallon: 9.39 lb Flash Point: NA Vehicle Type: Acrylic Shelf Life: 36 months,unopened
COMPLIANCE
As of 10/28/2021, Complies with:
OTC Yes OTC Phase II Yes S.C.A.Q.M.D. Yes CARB Yes CARB SCM 2007 Yes CARB SCM 2020 Yes Canada Yes LEED® v4 & v4.1 Emissions No LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified Yes MIR-Manufacturer Inventory No MPI® Yes
APPLICATION
Temperature:
minimum 35°F The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics. Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: No reduction necessary Airless Spray:
Pressure 2000 p.s.i.
Hose Tip Filter
1/4-3/8 inch I.D.
.015-.031 inch
30 mesh Brush Use a nylon-polyester brush Roller Cover Use a 1/2 to 11/2 inch nap synthetic cover Spray and backroll on porous & rough stucco to achieve required film build and a pin-hole free surface.
For porous block a coat of Loxon Acrylic Block Surfacer is required to achieve a pinhole free surface.
Apply at temperatures above 35°F. When the air temperature is at 35°F, substrates may be colder;
prior to painting, check to be sure the air, surface, and material temperature are above 35°F and at least 5°F above the dew point. Avoid using if rain or snow is expected within 2-3 hours.
Do not apply at air or surface temperatures below 35°F or when air or surface temperatures may drop below 35°F within 48 hours.
Do not paint in direct sun or on a hot surface.
Do not reduce.
APPLICATION TIPS
Apply paint at the recommended film thickness and spreading rate as indicated on the page. Application of coating below minimum recommended spreading rate may adversely affect the coating systems performance.
Loxon Block Surfacer is ready-to-spray (airless) and does not require thinning. Mix material thoroughly to a uniform consistency with power agitation and apply by brush, roller, or spray. If applied by airless spray, follow by roller, being careful to force material into pores in order to reduce pinholes and produce a relatively smooth surface. Squeegee or trowel will provide the smoothest finish. Two coats properly applied may be required to provide the most pinhole-free, uniform surface.
RECOMMENDED SYSTEMS
Concrete, Masonry, Cement 1 coat Loxon Acrylic Block Surfacer 2 coats Appropriate topcoat
CMU, Block, Split-face Block:
1 coat Loxon Acrylic Block Surfacer 2 coats Appropriate topcoat Recommended Architectural Topcoats:
A-100 Exterior Latex Loxon Masonry Coatings SuperPaint Exterior Duration Exterior Emerald Exterior Emerald Interior Duration Home ProClassic Interior ProMar Interior SuperPaint Interior Recommended Industrial Topcoats:
Acrolon 218 Polyurethane Pro Industrial Series Epolon II Multi-Mil Epoxy Industrial Enamels Macropoxy HS Epoxy Macropoxy 646 Steel Master 9500 Silicone Alkyd Tile-Clad HS Epoxy Water Based Catalyzed Epoxy
Industrial finishes have been tested for interior use only. Loxon Acrylic Block Surfacer has not been tested in environments subject to chemical attack. Any recommendations for use in such areas must follow a thorough evaluation of the effects of the environment on the Loxon Block Surfacer and topcoat system.
For exterior use, this primer-sealer must be topcoated within 14 days to prevent degradation due to weathering.
10/2021 www.sherwin-williams.com continued on back
Loxon® Acrylic Block Surfacer
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Scrape and sand peeled or checked paint to a sound surface. Sand glossy surfaces dull. Seal stains from water, smoke, ink, pencil, grease, etc. with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Masonry, Concrete, Cement, Block:
If needed, pressure clean to remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, peeling and defective coatings, chalk, form release agents, moisture curing membranes, etc. Allow the surface to dry thoroughly. Existing peeled or checked paint should be removed to a sound surface. Do not apply to smooth, slick surfaces. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Concrete and mortar must be cured at least 7 days at 75°F. Moisture content must be 15% or lower. On tilt-up and poured-in-place concrete, commercial detergents and sandblasting may be necessary to remove sealers, release compounds, and to provide an anchor pattern.
Fill bugholes, air pockets and other voids with an elastomeric patch or sealant.
SURFACE PREPARATION
Mildew:
Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach-water solution.
PHYSICAL PROPERTIES
Do not paint on wet surfaces.
LX01W0200
Water Vapor Permeance (US) : 35.99 perms Method: ASTM D1653 grains/(hr ft2 in Hg)
Flexibility:
Method: ASTM D522, method B, 180° bend, 3/4 inch mandrel Result: Pass
CAUTIONS
For interior exterior use only.
Must be topcoated for exterior use.
Protect from freezing.
Do not apply to damp or wet surfaces.
Do not use below grade as a hydrostatic waterproofer or in immersion service.
Do not apply at temperatures below 35°F. Air and surface temperatures must not drop below 35°F for 48 hours after application.
Before using, carefully read CAUTIONS on label.
CRYSTALLINE SILICA: Use only with adequate ventilation. To avoid overexposure, open windows and doors or use other means to ensure fresh air entry during application and drying. If you experience eye watering, headaches, or dizziness, increase fresh air, or wear respiratory protection (NIOSH approved) or leave the area. Adequate ventilation required when sanding or abrading the dried film. If adequate ventilation cannot be provided wear an approved particulate respirator (NIOSH approved). Follow respirator manufacturer’s directions for respirator use.Avoid contact with eyes and skin. Wash hands after using. Keep container closed when not in use. Do not transfer contents to other containers for storage. FIRST AID: In case of eye contact, flush thoroughly with large amounts of water.
Get medical attention if irritation persists. If swallowed, call Poison Control Center, hospital emergency room, or physician immediately. DELAYED EFFECTS FROM LONG TERM OVEREXPOSURE. Abrading or sanding of the dry film may release crystalline silica which has been shown to cause lung damage and cancer under long term exposure. WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.
DO NOT TAKE INTERNALLY. KEEP OUT OF THE
REACH OF CHILDREN.
HOTW 10/28/2021 LX01W0200 41 86
FRC, SP
CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with a compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.
113.12SGA
Pro Industrial™ Waterbased Alkyd Urethane Enamel Semi-Gloss B53–5150 Series
04/2025 www.sherwin-williams.com continued on back
CHARACTERISTICS
Pro Industrial Waterbased Alkyd Urethane Enamel is a premium quality interior-exterior enamel formulated with a urethane modified alkyd resin system for high performance. It provides beauty and durability when applied to interior-exterior surfaces such as properly prepared drywall, wood, masonry, and metal. It brings together the convenience and ease of use of a waterborne coating with the performance and coating characteristics of a traditional oil-based enamel.
• Excellent washability, flow and leveling
• Excellent touch up
• Easy application & cleanup
• Resistant to yellowing compared to traditional alkyds
• Suitable for use in USDA inspected facilities
For use on properly prepared: Steel, Galvanized & Aluminum, Drywall, Concrete and Masonry, and Wood.
Finish: 50-70 units @ 60° Color: Most Colors
Recommended Spreading Rate per coat:
Wet mils: 4.0-5.0 Dry mils: 1.3-1.7 Coverage: 320-407 sq. ft. per gallon Theoretical Coverage: 529 sq. ft. per gallon @ 1 mil dry Approximate spreading rates are calculated on volume solids and do not include any application loss.
Note: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.
Drying Schedule @ 4.0 mils wet, @ 50% RH:
Drying and recoat times are temperature, humidity, and film thickness dependent.
@77°F To touch 1-2 hours To recoat 4 hours
Tinting with CCE only:
Base oz. per gallon Strength Extra White 0-6 SherColor Deep Base 4-12 SherColor Ultradeep Base 10-14 SherColor
Extra White B53W05151 (may vary by color)
V.O.C. (less exempt solvents):
less than 50 grams per litre; 0.42 lbs. per gallon
As per 40 CFR 59.406 Volume Solids: 33 ±2% Weight Solids: 48 ±2% Weight per Gallon: 10.64 lbs Flash Point: N.A.
Vehicle Type: Urethane Modified Alkyd Shelf Life: 36 months, unopened
COMPLIANCE
As of 04/01/2025, Complies with:
OTC Yes OTC Phase II Yes S.C.A.Q.M.D. Yes CARB Yes CARB SCM 2007 Yes CARB SCM 2020 Yes Canada Yes LEED® v4 & v4.1 Emissions No LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified Yes MIR-Manufacturer Inventory No
MPI® #169
APPLICATION
Temperature:
minimum 50°F / 10°C maximum 100°F / 37.8°C air, surface and material At least 5°F above dew point
Relative humidity: 85% maximum The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics.
Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: Water
Airless Spray:
Pressure 2000 p.s.i.
Hose ¼ inch I.D.
Tip .013-.017 inch Filter 60 mesh Reduction: Not recommended
Brush: Use a nylon-polyester brush such as Purdy® Syntox®.
Roller Cover: Use a 1/4-1/2 inch woven cover such as Purdy® White Dove™.
If specific application equipment is listed above, equivalent equipment may be substituted.
Apply paint at the recommended film thickness and spreading rate as indicated. Application of coating above maximum or below minimum recommended spreading rate may adversely affect coating performance.
No painting should be done immediately after a rain or during foggy weather.
When using spray equipment, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. Apply coating evenly while maintaining a wet edge to prevent lapping.
SPECIFICATIONS
Steel:
1 coat Pro Industrial Pro-Cryl Primer 2 coats Pro Industrial Waterbased Alkyd Urethane
Aluminum & Galvanizing:
1 coat Pro Industrial Pro-Cryl Primer 2 coats Pro Industrial Waterbased Alkyd Urethane
Concrete Block (CMU):
1 coat Pro Industrial Heavy Duty Block Filler or Loxon Acrylic Block Surfacer 2 coats Pro Industrial Waterbased Alkyd Urethane
Concrete-Masonry:
1 coat Loxon Concrete & Masonry Primer or 1 coat Loxon Conditioner 2 coats Pro Industrial Waterbased Alkyd Urethane
Drywall:
1 coat ProMar 200 Zero V.O.C. Primer 2 coats Pro Industrial Waterbased Alkyd Urethane
Wood, exterior:
1 coat Exterior Wood Primer 2 coats Pro Industrial Waterbased Alkyd Urethane
Wood, interior:
1 coat Premium Wall & Wood Primer 2 coats Pro Industrial Waterbased Alkyd Urethane
The systems listed above are representative of the product’s use, other systems may be appropriate.
Pro Industrial™ Waterbased Alkyd Urethane Enamel Semi-Gloss
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS
SURFACE PREPARATION
WARNING! If you scrape, sand or remove old paint, you may release lead dust. LEAD IS TOXIC.
EXPOSURE TO LEAD DUST CAN CAUSE
SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE,
ESPECIALLY IN CHILDREN. PREGNANT WOMEN
SHOULD ALSO AVOID EXPOSURE. Wear a NIOSH-approved respirator to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the National Lead Information Hotline at 1-800-424- LEAD or log on to www.epa.gov/lead.
Do not use hydrocarbon solvents for cleaning.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry.
Existing peeled or checked paint should be scraped and sanded to a sound surface. Glossy surfaces should be sanded dull. Stains from water, smoke, ink, pencil, grease, etc. should be sealed with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Iron & Steel - Minimum surface preparation is Hand Tool Clean per SSPC-SP2. Remove all oil and grease from surface per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6.
Primer recommended for best performance.
Aluminum - Remove all oil, grease, dirt, oxide, and other foreign material per SSPC-SP1. Prime the area the same day as cleaned.
Galvanizing - Allow to weather a minimum of six months prior to coating. Solvent Clean per SSPC- SP1. When weathering is not possible, or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test patch.
Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP16 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2. Prime the area the same day as cleaned.
Concrete Block - Surface should be thoroughly clean and dry. Air, material, and surface temperatures must be at least 55°F (13°C) before filling. Use Pro Industrial Heavy Duty Block Filler or Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating.
Masonry – All masonry must be free of dirt, oil, grease, loose paint, mortar, masonry dust, etc. Clean per SSPC- SP13/Nace 6/ ICRI No. 310.2R, CSP 1-3. Poured, troweled, or tilt-up concrete, plaster, mortar, etc. must be thoroughly cured at least 30 days at 75°F. Form release compounds and curing membranes must be removed by brush blasting. Brick must be allowed to weather for one year prior to surface preparation and painting. Prime the area the same day as cleaned.
Weathered masonry and soft or porous cement board must be brush blasted or power tool cleaned to remove loosely adhering contamination and to get to a hard, firm surface. Apply one coat Loxon Conditioner, following label recommendations.
Wood - Surface must be clean, dry, and sound. Prime with recommended primer. No painting should be done immediately after a rain or during foggy weather. Knots and pitch streaks must be scraped, sanded and spot primed before full coat of primer is applied. All nail holes or small openings must be properly caulked.
SURFACE PREPARATION
Previously Painted Surface - If in sound condition, clean the surface of all foreign material. Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary. Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Mildew - Clean mildew from the Surface: Mildew is a fungus that looks like dirt but won’t wash off. Mildew must be removed before painting, or it will grow through any new coat of paint. To remove mildew or suspected mildew, scrub surface before painting with a commercial mildew remover following manufacturer’s safety instructions.
PERFORMANCE
System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation SSPC-SP10 Finish: Pro Industrial Waterbased Alkyd Urethane @5.0 W.F.T.
Adhesion:
Method: ASTM D3359 method B Result: 4B
Pencil Hardness:
Method: ASTM D3363 Result: 4H
Flexibility:
Method: ASTM D522, 180° bend, 1/8 inch mandrel Result: Pass
Dry Heat Resistance:
Method: ASTM D2485 Result: 200°F
Block Resistance:
Method: Lab assessment Result: Excellent
Resistance Yellowing:
Method: Lab assessment Result: Excellent
No painting should be done immediately after a rain or during foggy weather.
Do not paint on wet surfaces.
Check adhesion by applying a test strip to determine the readiness for painting.
SAFETY PRECAUTIONS
Before using, carefully read CAUTIONS on label.
Refer to the Safety Data Sheets (SDS) before use.
FOR PROFESSIONAL USE ONLY.
Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.
CLEANUP INFORMATION
Clean spills, spatters, hands, and tools immediately after use with soap and warm clean water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
Danger: Rags, steel wool, other waste soaked with this product, and sanding residue may spontaneously catch fire if improperly discarded.
Immediately place rags, steel wool, other waste soaked with this product, and sanding residue in a sealed, water-filled, metal container. Dispose of in accordance with local fire regulation.
HOTW 04/01/2025 B53W05151 06 28
FRC, SP
http://www.paintdocs.com/
Paint CMU Surface Beige
Paint Color of All Vertical Surfaces to Match this Beige
Paint Brick Surface Beige
Trim to Remain Black
Project Southwest Corner jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
Paint Vertical Surfaces
Trim to Remain Black jcfrancis Line
Trim to Remain Black
Beige
Repair Stucco jcfrancis Line jcfrancis Line
Paint Trim Black
Paint Overhead Door White
Repair Stucco
Paint Vertical Surfaces Beige
Doors to Remain Gray jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
Beige
Paint Overhead Door White jcfrancis Line jcfrancis Line jcfrancis Line
Paint Overhead Doors White Paint Trim Black
Paint Vertical Surfaces Beige
Paint Door Trim Black jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
White
Paint Vertical Surfaces Beige
Doors to Remain Gray jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
White
Paint Vertical Surfaces Beige jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
White
Paint Vertical Surfaces Beige jcfrancis Line jcfrancis Line jcfrancis Line jcfrancis Line
Leave Trim Black
Additive Alternate Northwest Wall jcfrancis Line jcfrancis Line jcfrancis Line
Leave Trim Black
Project Northwest Corner
Additive Alternate Northwest Wall jcfrancis Line jcfrancis Line jcfrancis Line
Add a number to each Overhead Door - Black on White
File details come from the government source that posted it. Updated .