2-03 Drawing Material Handlers.pdf
PDF 284 KB Posted
- Solicitation number
- Not on record
- Issued by
- York County, Pennsylvania
About this file
This is a technical drawing document for the York County Solid Waste and Refuse Authority (YCSWA) Blackbridge Road Transfer Station Construction Project, prepared by Providence Engineering Corp. The project involves the procurement and installation of two (2) Stationary Electric Material Handlers (SEMH). Bids for this work will be received online via PennBid until 10:00 a.m. local time on Tuesday, March 10, 2026, with public opening and reading of bids at the YCSWA Management Center located at 2700 Blackbridge Road, York, PA 17406. Bidding documents became available at no cost through the PennBid Program beginning Monday, February 16, 2026. A non-mandatory pre-bid conference is scheduled for Tuesday, February 24, 2026, at 10:00 a.m. at the Management Center, with virtual attendance available upon request to Terry Simpson at tsimpson@armgroup.net. The technical drawings provide detailed specifications for the two SEMH units, including their placement on the tipping floor, electrical and hydraulic utility requirements, access platforms, railings, ladders, and anchor bolt installation details based on the assumed BuiltRite Model 2150-SE specification.
Bid security must be furnished in the form of a certified check or bid bond in an amount not less than 10% of the bid. The SEMH vendor/installer is responsible for supplying all procurement, installation, coordination, and utility requirements to the owner and contractors under the main project package. Final shop drawings and cut sheets for the purchased units must be provided to the engineer prior to construction commencement for review and approval. The vendor must coordinate trench pathways, utility locations, and anchor bolt specifications with the general contractor and engineer, with all clear space and installation requirements to be verified prior to the start of construction. Questions regarding the bidding documents must be submitted through the PennBid Program, with no telephone inquiries accepted and an established RFI deadline provided on the platform.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J KF G H
10'-8"
ELECTRIC / IT
SPRINKLER
ROOM
20'-0" 20'-0" 20'-0"
STAIR
ST-1
OPEN
STATIONARY ELECTRIC
MATERIAL HANDLER, SEE
NOTE 1
36" HIGH CONCRETE BACK
WALL BY GC. SEE MAIN
PROJECT PACKAGE, TYP.
OPEN
OPEN
OPEN
PIT DEFLECTOR
EL. = (+0'-0")
FINISH FLOOR
'-0
'-0
'-0
DN
DN
EQUIPMENT
ROOM
STATIONARY ELECTRIC
MATERIAL HANDLER,
SEE NOTE 1
'-0
'-0
'-0
'-0
TIPPING FLOOR
APPROXIMATE PATH OF TRENCH
FOR STATIONARY ELECTRIC
MATERIAL HANDLER UTILITIES -
SEE DETAIL A/SMH01, TYP.
SEMH01
SEMH01
REMOTE POWER UNITS FOR
STATIONARY MATERIAL
HANDLER UNITS TO BE
LOCATED IN THIS ROOM
PLAN NOTES
1. PROCURE AND INSTALL STATIONARY ELECTRIC MATERIAL HANDLERS (SEMH). SEMH VENDOR/INSTALLER TO SUPPLY ALL REQUIREMENTS AND COORDINATION ITEMS TO THE OWNER AND CONTRACTORS UNDER THE MAIN
PROJECT PACKAGE. SEE SEMH SPECIFICATION SECTION FOR ADDITIONAL INFORMATION.
2. REFERENCE THE MAIN PROJECT BID PACKAGE FOR ADDITIONAL INFORMATION: BUILDING, STRUCTURAL, ELECTRICAL, ETC.
HYDRAULIC AND ELECTRIC
UTILITIES, BY STATIONARY
ELECTRIC MATERIAL
HANDLER VENDOR
6" MAX. CLEAR - VERIFY
WITH STATIONARY ELECTRIC
MATERIAL HANDLER PRIOR TO
THE START OF CONSTRUCTION
1'-5" MAX. - VERIFY WITH
STATIONARY ELECTRIC
MATERIAL HANDLER
PRIOR TO THE START OF
CONSTRUCTION
SEE MAIN PROJECT DOCUMENTS
FOR INFORMATION NOT CALLED OUT
2" 10" 10" 10" 10" 2"
3'-8"
2"
2"
3' -8
(16) 1 1/4" DIA. A193 GRADE B7
ANCHOR BOLTS WITH DOUBLE
A194 GRADE 2H HEAVY HEX
NUTS TOP AND BOTTOM,
ASSUMED, COORDINATE WITH
FINAL STATIONARY ELECTRIC
MATERIAL HANDLER SHOP
DRAWINGS
PLATE PER STATIONARY ELECTRIC
HANDLER MANUFACTURER
PLATE CENTERLINE
PLATE CENTERLINE
FINISH FLOOR
EL. = (SEE PLAN)
B O
LT
P
R O
JE
C
T
IO
N 7"
A N
C H
O R
E M
B E
D M
E N
T
2' -4
A
N C
H O
R B
O
LT
1' -6
1 1/2" HIGH STRENGTH NON-SHRINK
GROUT PER STATIONARY ELECTRIC
MATERIAL HANDLER MANUFACTURER'S
RECOMMENDATIONS
ANCHOR BOLT - SEE DETAIL F/S401
FOR ADDITIONAL INFORMATION
PLATE PER STATIONARY ELECTRIC
MATERIAL HANDLER MANUFACTURER
STATIONARY ELECTRIC MATERIAL
HANDLER
CENTERLINE OF CONCRETE BEAM AND
STATIONARY ELECTRIC MATERIAL HANDLER
SEE MAIN PROJECT DOCUMENTS
FOR INFORMATION NOT CALLED OUT
FINISH FLOOR EL.
EL. = (0'-0")
2 3 4 5 6 7
PIT FLOOR
EL. = (-18'-6")
PIT
EL. = (-22'-0")
TIPPING FLOOR
PIT
STATIONARY ELECTRIC
MATERIALHANDLER (SEMH) -
SEE PLAN, TYP. (2)
SEMH TO INCLUDE ACCESS
PLATFORM, RAILING AND
LADDER FROM FLOOR
BEHIND WALL
SEMH ELEMENTS MUST
CLEAR ADJACENT
CONCRETE WALLS, TYP.
FINISH FLOOR EL.
EL. = (0'-0")
PIT FLOOR
EL. = (-18'-6")
PIT
EL. = (-22'-0")
JF G H
EAVE
EL. = (36'-0")
PIT
STATIONARY ELECTRIC
MATERIAL HANDLER
(SEMH) - SEE PLAN, TYP. (2)
TIPPING FLOOR
SEMH TO INCLUDE ACCESS
PLATFORM, RAILING AND
LADDER FROM FLOOR
BEHIND WALL
Phone: 717-509-7000 Lancaster, PA 17603
10 Eisenhower Boulevard
DRAWN BY:
CHECKED BY:
DATE
SCALE:
JOB NO.:
SHEET:
REVISION -
C op yr ig ht
N ot ic e, P ro vi de nc e
En gi ne er in g
Al l R ig ht s
Re se rv ed
. T he se p la ns a re th e pr op er ty o f P ro vi de nc e En gi ne er in g Co rp . A ny u se o r r ep ro du ct io n of th es e pl an s, in w ho le o r i n pa rt
, w ith ou t p er m is si on o f P ro vi de nc e
En gi ne er in g
Co rp
. i s ill eg al , f or bi dd en
. F ur th er a ny pa rt y th at w ou ld d o su ch is d oi ng a t s ol e ris k.
AS NOTED
Certificate Number: 3869
02/16/26
SEMH01
231718
JAH/BIF
KDL
S T
A T
IO
N
A R
Y E
L E
C T
R
IC
M A
T E
R
IA
L H
A N
D L E
R S
S
E M
H
B L A
C K
B R
ID
G
E R
O A
D Y
O R
K T
R A
N S
F E
R S
T A
T
IO
N
B L A
C K
B R
ID
G
E R
O A
D
W E
S T
G O
V E
N O
R R
O A
D P
.O
B O
X
A R
M G
R O
U P
H E
R S
H E
Y P
A
Y O
R K
C O
U N
T Y
S O
L
ID
W A
S T
E A
N D
R E
F U
S E
A U
T H
O R
IT
Y
Y O
R K
P
A
P R
E L
IM
IN
A R
Y
IS
S
U E
D F
O R
B
ID
D
IN
G O
N L
Y
N O
T F
O R
C O
N S
T R
U C
T
IO
N R
E V
IS
IO
N D
A T
E B
Y
IS
S U
E D
F O
R S
M H
B
ID
D
IN
G
/1
/2
JA
H /B
IF
N O R
THSCALE: 1/8" = 1'-0"
PARTIAL TIPPING FLOOR PLAN
STATIONARY ELECTRIC MATERIAL HANDLER NOTES FOR DETAILS F/S401
AND G/S401
1. INFORMATION SHOWN IS ASSUMED BASED ON BUILTRITE STATIONARY
ELECTRIC MATERIAL HANDLER MODEL 2150-SE.
2. FINAL CUT SHEETS FOR THE PURCHASED UNIT TO BE PROVIDED TO
THE ENGINEER PRIOR TO THE START OF CONSTRUCTION FOR
REVIEW. FOLLOWING REVIEW, DETAILS SHOWN MAY REQUIRE
REVISION.
3. STATIONARY ELECTRIC MATERIAL HANDLER MANUFACTURER TO
PROVIDE ANCHOR BOLT SIZE, GRADE, AND PROJECTION
REQUIREMENTS TO THE G.C.
4. STATIONARY ELECTRIC MATERIAL HANDLER MANUFACTURER TO
SUPPLY ANCHOR BOLT TEMPLATE TO G.C. FOR THEIR USE.
5. STATIONARY ELECTRIC MATERIAL HANDLER TO BE SOURCED AND
INSTALLED UNDER THIS BID PACKAGE.
NO SCALESEMH01
A
STATIONARY ELECTRIC MATERIAL
HANDLER TRENCH
NO SCALESEMH01
B
STATIONARY ELECTRIC MATERIAL
HANDLER PLATE
NO SCALESEMH01
C
STATIONARY ELECTRIC MATERIAL
HANDLER
SECTION
SEMH01 SCALE: 1/8" = 1'-0"
SECTION
SEMH01 SCALE: 1/8" = 1'-0"
| Sheets |
| SEMH01 - STATIONARY ELECTRIC MATERIAL HANDLERS (SEMH) |
File details come from the government source that posted it. Updated .