18230 ADD 4 Attachment #3 -REVISED Civil Specification Page 61.pdf

PDF 119 KB Posted

Attached to
Paulette Burdick Park
Solicitation number
IFB 410 18230 5
Issued by
Palm Beach County, Florida

About this file

This file is a civil specification document for the Paulette Burdick Park project in Palm Beach County, Florida, dated June 21, 2024, and addresses concrete mix design requirements and approval procedures. The specification details the execution requirements for concrete proportioning, requiring contractors to proportion mixes using either laboratory trial batch or field experience methods in compliance with ACI 211.1 standards. The contractor is responsible for providing all testing services and must submit a mix design for each concrete class to the Architect/Engineer for approval at least 15 days prior to work commencement. Production cannot begin until mixes receive written approval. The specification mandates compression strength requirements of 3,250 pounds per square inch.

The specification requires detailed reporting on concrete composition, including total weights of water, cement, coarse and fine aggregates, admixtures, slump, air percentage, and compression test results for six cylinders tested at 7, 14, and 28 days. When field experience methods are used for proportioning, contractors must establish proportions per ACI 301-72 standards and provide strength data from at least 30 consecutive tests or statistical averages from two groups totaling 30 or more tests representing similar materials and project conditions. The document references ACI 211.1 as the standard practice for selecting concrete proportions for normal and heavy weight concrete to achieve the specified strength requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Palm Beach County 100% Bid Set Paulette Burdick Park June 21, 2024

PART 4 - EXECUTION

4.1. GENERAL

A. Proportioning

1. Proportion mixes by either laboratory trial batch or field experience methods, using materials to be employed on the project for each class of concrete required, complying with the latest edition of ACI 211.1.

2. Contractor shall provide all testing services for approval of mixes.

3. The Contractor shall furnish the Architect/Engineer for approval a mix design for each class of concrete at least 15 days prior to start of work.

B. Report to Include

1. Total weight of water, cement, coarse aggregate fine aggregate and admixtures to be used.

2. Slump.

3. Percent of Air.

4. Results of Compression Test for 6 cylinders cast and broken 7, 14 and 28 days.

5. Grain size curves for both aggregates.

C. Do not begin production until mixes have been approved by Architect/Engineer.

D. When field experience methods are used to select concrete proportions, establish proportions as specified in ACI 301-72. Strength data for establishing standard deviation will be considered suitable if the concrete production facility has certified records consisting of at least 30 consecutive tests in one group or the statistical average for 2 groups totaling 30 or more tests, representing similar materials and project conditions.

E. The proper proportions of cement, aggregate and water to obtain the required strength shall be determined from ACI 211.1 "Recommended Practice for Selection Proportions for Normal and Heavy Weight Concrete".

1. Strength requirements shall be 3250 pounds per square inch.