Attachment_D-2_Drawings.pdf

PDF 261 KB Posted

Attached to
Lab Renovation, Building 26, Room B114 Federal contract opportunity
Solicitation number
18-223-SOL-00027
Issued by
Department of Health and Human Services Food and Drug Administration

About this file

Attachment D-2 Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Lab Renovation, Building 26, Room B114, newest first.
File Type Posted
Amendment_0001.pdf PDF
Solicitation_18-223-SOL-00027.pdf PDF
Attachment_D-3_U.S._Department_of_Labor_General_Decision_Number_AR180036,_dated_01052018_AR36.pdf PDF
Attachment_D-1_Scope_of_Work.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment D-2 – Drawings

ES/EW

ES ES ES ES

ES ES ES

DN

UP

SKYLIGHT

EWC

FE

TYP.

EL.274'-2 1/8"

AP

AP

AP

AP

AP

AP

24"x24"

ACCESS

PANEL

AT FLR

(TYP)

TYP.

ACCESS GRATE

FEFEFEFE FEFEFEFE

FEFEFE FEFEFE

FEFEFE FEFEFEFE

FEC

FD

3'-0"

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

GEN CHEM

MICRO LAB

FREEZER

ELECT

SHOP OFFICE

AARL741

AARL741

AARL741

1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1

3 3 3 3 3 3 3 3 3 3 3 33 3 33 3 3

3 3 3 3 3 3 3 3 3 3 3 33 33 3 3

S1

S1S1S1S1S1S1S1S1

S1 S1 S1 S1 S1 S1 S1

SEE DETAILS 2 AND 3/A-ARL-631

FOR SERVICE CORRIDOR SECTIONS

VAV CONTROL PANEL

LOCATION,TYPICAL

VAV CONTROL PANEL

LOCATION, TYP.

MA

TC

HL

IN

E

SE

E

DR

AW

IN

G A

AR

L 7

S1

FE

S1S1

S1S1

FE

S1S1

S1

S1S1S1S1S1S1

S1 S1 S1 S1 S1 S1S1

FE

S1S1

S1S1

FE

S1S1

S1

S1S1

FE

A-ARL-811

COPIER (NIC)

B152 B148 B144 B140

B128 B122

B152B152

B118 B114B134

B129 B123 B121

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N

W

T

EWEWEWEWEWEWEWEW

D I

PB

PB

PB PB PB PB

PB

PB PB

WT

W T

D I

D I

D I

CW

(C

S)

V N CW

(C S)

V N CW

(C

S)

V N CW

(C S)

V N CW

(C

S)

V N CW

(C S)

V N CW

(C

S)

V N CW

(C S)

V N

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N

EWEW

PB

PB

PB

D I

CW

(C

S)

V N CW

(C S)

V N

6' FH6' FH

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

A V N

EWEW

PB

PB

PB

WT

D I

CW

(C

S)

V N CW

(C S)

V N

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

A V N

EWEWEWEWEWEW

D I

PB PB PB

PB

PB PB

WT

W T

D I

D I

CW

(C

S)

V N CW

(C S)

V N CW

(C

S)

V N CW

(C S)

V N CW

(C

S)

V N CW

(C S)

V N

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N

EWEW

PB

PB

PB

D I

CW

(C

S)

V N CW

(C S)

V N

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

CW

CS

A V N

A V N

CW

CS

C/T

C/T

A V N

EWEW

PB

PB

PB

WT

D I

CW

(C

S)

V N CW

(C S)

V N

C/T

C/T

A V N

EWEW

PB D

I

B

C

D

E

A.7

2 3 4 5 6

E.3

A

F

ES

ESES

ES

W

T

ESES

ESESES

ESESES

AREA OF WORK - ROOM B114

REFER TO SHEET A-102

Scale

Date

Drawn By

Checked By

Project Number

National Center for Toxicological Research

Food and Drug Administration

3900 NCTR Road Jefferson, AR 72079

3/16" = 1'-0"

3/

/2

:1 6:

A

M

A101

BUILDING 26

FIRST FLOOR "B"

Checker Author

Issue Date Project Number

3/16" = 1'-0"

1 BUILDING 26 FIRST FLOOR "B" PLAN

NORTH

No. Description Date

FEFE

ES

3 3 3

S1S1

S1 S1

BH

J3

BH

A4

BH

H3

BH

J4

BH

A3

AH

B3

W

CF

W

CF

W

CF

BH

H3

AH

B3

SH

B4

SH

B4

BH

J3

BH

J3

BH

H4

BH

H4

SS

C3

SS

C3

SS

C3

SS

C3

BH

H4

BH

H4

W

CF

W

CC

W

CC

W

CC

W

CC

W

CC

W

CC

SHA60

1 1

B114

GEN CHEM

MICRO LAB

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

A V N

A V N

C/T

C/T

A V N

EWEW

D I

PB

CW

(C

S)

V N CW

(C S)

V N

ES

RACEWAY TO REMAIN.

RACEWAY TO BE

REMOVED.

CONTRACTOR SHALL

VALVE AND CAP

GASES UNDER

COUNTER.

ELECTRICAL RACEWAY TO REMAIN (BOTH

MODULES)

CONTRACTOR SHALL

REMOVE SINK,

CABINETRY AND

COUNTER.

CONTRACTOR SHALL FURNISH AND INSTALL NEW

COUNTER WITH BACKSPLASH. COUNTER SHALL BE

INSTALLED WITH LIP. BACKSPLASH SHALL EXTEND TO

BOTTOM OF EXISTING RACEWAY.

RETAIN CABINETS

CONTRACTOR SHALL

REMOVE BOTTLE

DRYING RACK AND

REINSTALL ABOVE

NEW COUNTER.

YELLOW BOXES

INDICATE NEW

DOUBLE SINK, WITH

GARBAGE DISPOSAL

UNDERNEATH. EACH

SINK SHALL BE

INSTALLED WITH A

FAUCET AND

SPRAYER.

CONTRACTOR SHALL REMOVE SINK AND

EYE WASH. DOMESTIC WATER SYSTEMS

AND SANITARY SYSTEMS SHALL BE REUSED.

COUNTER TOP TO BE STAINLESS STEEL

WITH LIP.

DI WATER SHALL BE

RETAINED.

NEW BACKSLASH SHALL BE

INSTALLED FOR UTILITY

DROP.

YELLOW BOX INDICATE

NEW SINK, WITH

GARBAGE DISPOSAL

UNDERNEATH. SINK

SHALL BE INSTALLED

WITH A FAUCET AND

SPRAYER. EXISTING

EYEWASH SHALL BE

REMOVED AND REPLACE

WITH NEW OF SAME

STYLE EQUAL TO

GUARDIAN, OR APPROVED

EQUAL.

THREE NEW GFCI

DUPLEX OUTLETS

SHALL BE

INSTALLED ON

OTHER SIDE OF

CHASE, TYPICAL

BOTH CHASES.

CONTRACTOR

SHALL REMOVE

LOWER

CABINETRY UNIT.

ELECTRICAL RACEWAY TO REMAIN.

CONTRACTOR SHALL REMOVE

UPPER AND LOWER CABINETRY

MODULES. CONTRACTOR SHALL

REMOVE COUNTER.

CONTRACTOR SHALL

VALVE AND CAP GASES

IN CHASE.

CONTRACTOR SHALL REMOVE CABINETS. REMOVE

SYSTEM IN ENTIRETY, INCLUDING SUPPORTS FROM

STRUCTURE ABOVE, BELOW AS WELL AS METAL

CLOSURES HORIZONTAL CHASES.

CONTRACTOR SHALL DEMOLISH

ELECTRICAL RACEWAY, REMOVE

WIRING TO PANEL AND PROVED

SPARES.

METAL FRAMED

ELECTRICAL RACEWAY

TO REMAIN. OPPOSITE

TO REMAIN.

NEW BACKSPLASH

SHALL WRAP UTILITY

DROP. (TYPICAL EACH

CHASE)

CONTRACTOR SHALL

FURNISH AND INSTALL

THREE DUPLEX

OUTLETS, GFCI

PROTECTED FOR EACH

UTILITY DROP.

OUTLETS FACING

TOWARD CENTER OF

ISLAND, ABOVE NEW

BACKSPLASH (EACH

UTILITY CHASE)

EXISTING UTILITY CHASES SHALL BE PATCHED

WITH METAL, EXTENDING EDGE TO EDGE, AND

PAINTED WHERE CENTER CABINETS ARE TO BE

REMOVED (BOTH UTILITY CHASES). EACH

CHASE SHALL BE PAINTED.

CONTRACTOR SHALL

FURNISH AND INSTALL

THREE DUPLEX

OUTLETS, GFCI

PROTECTED FOR EACH

UTILITY DROP.

OUTLETS FACING

TOWARD CENTER OF

ISLAND, ABOVE NEW

BACKSPLASH (EACH

UTILITY CHASE)

CONTRACTOR SHALL REMOVE

CABINETRY, SHELVING AND

COUNTER. CONTRACTOR

SHALL LEVEL FLOOR AND

PATCH FLOORING SYSTEM.

(THIS MODULE ONLY)

CONTRACTOR SHALL

VALVE AND CAP

GASES IN WALL

CABINETRY, SHELVING AND COUNTER TO

REMAIN (THIS MODULE ONLY). ELECTRICAL

RACEWAY TO REMAIN (BOTH MODULES)

EXISTING FUME

HOOD TO REMAIN.

EXISTING FUME

HOOD TO REMAIN.

CONTRACTOR SHALL REMOVE SINK. EXISTING WATER AND SANITARY LINES FEEDING SINK

SHALL BE CAPPED UNDER COUNTER. HOLE WHERE EXISTING SINK WAS SHALL BE PATCHED

AND BRACED UNDER COUNTER. NEW STAINLESS STEEL COUNTER WITH LIP SHALL BE

FURNISHED AND INSTALLED. BACKSPLASH SHALL EXTEND TO EXISTING RACEWAY. EXISTING

DRYING RACK SHALL BE REINSTALLED ABOVE.

CONTRACTOR SHALL FURNISH AND INSTALL STAINLESS STEEL COUNTER TOP WITH LIP.

BACKSPLASH SHALL EXTEND TO EXISTING ELECTRICAL RACEWAY.

ELECTRICAL

RACEWAY TO

REMAIN. SHELVING

TO REMAIN.

LOWER SHELVING

UNIT TO REMAIN.

IMAGE SHOWN IS TO ILLUSTRATE TYPICAL UNDER SINK EXISTING CONDITION AND

PRESENCE OF WATER AND MEDICAL GAS IN CHASE UNDER EXISTING LOWER COUNTER

SHELVING UNITS. WATER AND MEDICAL GASES ARE COPPER. SINK DRAIN LINE IS ACID

RESISTANT EQUAL TO ORION, MECHANICALLY FASTENED. MODIFICATIONS TO MEDICAL

GASES SHALL BE MADE WITH MEDICAL GRADE PIPE, VALUES AND METHODS. WHEN ANY

LOWER CABINET MODULE IS DEMOLISHED, PIPING IN CHASE SHALL BE PROTECTED.

CONTRACTOR SHALL FURNISH AND INSTALL STAINLESS STEEL PLATE ENVELOPING

CHASE. PLATE SHALL BE REMOVABLE.

Scale

Date

Drawn By

Checked By

Project Number

National Center for Toxicological Research

Food and Drug Administration

3900 NCTR Road Jefferson, AR 72079

As indicated

3/

/2

:1 6:

A

M

A102

ROOM B114

DEMOLITION

Checker Author

Issue Date Project Number

1/4" = 1'-0"

1 EXISTING ROOM B114

N.T.S.

5 PHOTO 3

N.T.S.

7 PHOTO 5

N.T.S.

2 PHOTO 1

N.T.S.

6 PHOTO 4

N.T.S.

10 PHOTO 8

N.T.S.

3 PHOTO 2

N.T.S.

9 PHOTO 7

N.T.S.

8 PHOTO 6

KEYED NOTES:

1. PHOTO 1

2. PHOTO 2

3. PHOTO 3

4. PHOTO 4

5. PHOTO 5

6. PHOTO 6

7. PHOTO 7

8. PHOTO 8

NORTH

N.T.S.

4 TYPICAL EXISTING PLUMBING CHASE

GENERAL NOTES:

1. CONTRACTOR SHALL PATCH AREAS DAMAGED FROM THE REMOVAL

OF SHELVING UNITS.

2. CONTRACTOR SHALL REPAINT LAB. COLOR TO BE EQUAL TO

SHERMAN WILLIAMS 1102 CHENILLE WHITE PRO MAR 200 SEMI-GLOSS.

3. WHERE UNDER COUNTER UNITS ARE REMOVED, CONTRACTOR SHALL

FURNISH AND INSTALL STAINLESS STEEL PROTECTIVE COVER OVER

MEDICAL GAS AND WATER CHASE.

4. WHERE UNDER COUNTER UNITS ARE REMOVED, CONTRACTOR SHALL

TURN VINYL FLOORING DOWN AND SEAL IT TO CONCRETE FLOOR.

SEAL SHALL BE COMPLETE AND WATERTIGHT.

5. WATER AND MEDICAL GASES TO LAB SHALL BE SHUT OFF BEFORE

WORK BEGINS, CONTRACTOR SHALL COORDINATE WITH FACILITY TO

ESTABLISH DATE. FACILITY WILL EXECUTE SHUT OFF.

6. CONTRACTOR SHALL COORDINATE WITH FACILITY ENSURE NEGATIVE

PRESSURE IN LAB DURING WORK. NEGATIVE PRESSURE WILL BE

MAINTAINED THROUGH EXISTING BUILDING SYSTEMS. CONTRACTOR

SHALL MAINTAIN FILTERS ON EXTERIOR OF EXHAUST GRILLES.

7. ALL COUNTERTOPS SHALL BE MINIMUM 18 GAUGE.

8. ALL NEW SINKS SHALL BE FURNISHED AND INSTALLED WITH NEW

FAUCETS AND SPRAYERS (WITH SPRAYER HOLDER) AS WELL AS

DRAIN AND DRAIN COVER.

9. ALL NEW GARBAGE DISPOSALS SHALL BE FURNISHED AND INSTALLED

WITH DISCONNECT AND CLEANOUT AT CONNECTION TO MAIN.

10. CONTRACTOR'S SHALL BE RESPONSIBLE FOR FURNISHING

PORTAPOTTY FOR WORKER'S USE, COORDINATE WITH GOVERNMENT

FOR PLACEMENT.

11. CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE OF MATERIAL

OFFSITE, ON ONSITE IN STORAGE CONTAINER, COORDINATE WITH

GOVERNMENT FOR PLACEMENT.

12. ALL FAUCETS, GARBAGE DISPOSALS, SPRAYERS, EYE WASHES,

PIPING, VALVES AND COUNTERTOP SPECIFICS SHALL BE SUBMITTED

TO GOVERNMENT FOR APPROVAL.

13. ALL BACKSLASHES SHALL BE SEAMLESS AND SEALED TO

ACCOMMODATE PREPARATION OF FOOD.

14. ALL BACKSLASHES SHALL BE SEALED WATERTIGHT TO ADJACENT

MATERIAL INCLUDING WALL, CABINET OR FUME HOOD.

15. CONTRACTOR SHALL REPAINT SURFACES OF EXPOSED SHELVING

UNITS INCLUDING THOSE SURFACES TO BE EXPOSED WHEN

DESIGNATED CABINET MODULES ARE REMOVED.

ES

3 3 3

S1S1

S1 S1

BH

J3

BH

A4

BH

H3

BH

J4

BH

A3

AH

B3

W

CF

W

CF

W

CF

BH

H3

AH

B3

SH

B4

SH

B4

BH

J3

BH

J3

BH

H4

BH

H4

SS

C3

SS

C3

SS

C3

SS

C3

BH

H4

BH

H4

W

CF

W

CC

W

CC

W

CC

W

CC

W

CC

W

CC

SHA60

1 1

B114

GEN CHEM

MICRO LAB

6' FH6' FH

N

V

A

C/T

N

V

A

C/T

A V N

A V N

C/T

C/T

A V N

EWEW

D I

PB

CW

(C

S)

V N CW

(C S)

V N

ES

1 5

KEYED NOTES:

1. AREA FOR FUTURE FREEZE DRYER. (UPPER SHELVING AND

LOWER CABINETRY SHALL BE REMOVED).

2. EXISTING SINGLE SINK TO BE REPLACED WITH DOUBLE SINK

WITH DISPOSAL AND SPRAYER (ONE FAUCET AND SPRAYER

FOR EACH SINK, TWO TOTAL). COUNTER TO BE REPLACED

WITH NEW STAINLESS COUNTER WITH LIP AND

BACKSPLASH. BACKSPLASH SHALL EXTEND AROUND

NORTH SIDE OF COUNTER AND PROTECT THE SIDE OF THE

FUME HOOD. BACKSPLASH SHALL ETEND TO BOTTOM OF

EXISTING ELETRICAL RACEWAY. SEE REFERENCE PHOTO 2

THIS SHEET.

3. COUNTER TO BE REPLACED WITH NEW STAINLESS

COUNTER WITH LIP AND BACKSPLASH. REFER TO PHOTO 2

THIS SHEET.

4. EXISTING SINK TO BE REMOVED. ALL DOMESTIC AND

SANITARY LINES TO BE CAPPED BELOW COUNTER.

COUNTER TO BE REPLACED WITH NEW STAINLESS

COUNTER WITH LIP AND BACKSPLASH. BACKSPLASH SHALL

ETEND TO BOTTOM OF EXISTING ELETRICAL RACEWAY.

5. AREA FOR FUTURE USE. COUNTER SHALL BE REPLACED

WITH NEW STAINLESS COUNTER TOP AND BACKSPLASH.

6. EXISTING SINGLE SINK TO BE REPLACED WITH SINGLE SINK

WITH DISPOSAL, SPRAYER AND EYEWASH. COUNTER TO BE

REPLACED WITH NEW STAINLESS COUNTER WITH LIP AND

BACKSPLASH AROUND UTILITY DROPS. COUNTER FOR

ENTIRE ISLAND AREA SHALL BE REPLACED WITH NEW

STAINLESS COUNTER WITH LIP. SEE REFERENCE PHOTO 1

AND 3 THIS SHEET.

7. AREA FOR FUTURE FREEZER. (UPPER SHELVING AND

LOWER CABINETRY SHALL BE REMOVED).

8. CONTRACTOR SHALL PROVIDE NEW EYEWASH, THIS

LOCATION.

GENERAL NOTES:

1. ALL NEW ELECTRICAL OUTLETS SHALL BE PERMANENTLY

LABELED WILL CIRCUIT NUMBER AND VOLTAGE. ALL NEW

OUTLETS SHALL BE GFCI PROTECTED.

2. NEW SINKS SHALL BE MINIMUM 20" BY 18" BY 12" DEEP.

3. NEW FAUCETS SHALL BE LAB QUALITY, WRIST OPERATED

AND MANUFACTURED BY CHICAGO OR EQUIVALENT.

4. ALL BACKSPLASHES SHALL BE SEAMLESS, TO

ACCOMMODATE THE PREPARATION OF FOOD.

5. ALL COUNTERS AND SINKS SHALL BE 18 GAUGE STAINLESS,

MINIMUM.

DI WATER SHALL BE RETAINED.

BOTTLE DRYING

RACK ABOVE SINK

SHALL BE

RETAINED.

BOTH UTILITY DROPS ON CENTER

ISLAND SHALL BE FURNISHED AND

INSTALLED WITH BACKSPLASHES WITH

THREE DUPLEX OUTLETS ABOVE

BACKSPLASH. BACKSPLASH SHALL BE

SEAMLESS, SEALED TO

ACCOMMODATE PREPARATION OF

FOOD.

CONTRACTOR SHALL REPLACE COUNTER OF

EXISTING ISLAND WITH NEW STAINLESS

COUTER TOP WITH LIP. PHOTO OF EXSTING

COUNTER IN ROOM A350. SHOWN AS

REFERENCE.

EXISTING DISPOSAL CONTROL. SHOWN

AS REFERENCE. NEW SHALL INSTALLED

IN SIMILAR MANNER. EACH NEW

DISPOSAL SHALL BE INSTALLED ON

NEW, DEDICATED CIRCUIT, PROPERLY

LABELED AT THE PANEL.

NOTE: NEW DISCONNECT SHALL BE

FURNISHED AND INSTALLED ON

UNISTRUT FRAME SUPPORTED

FROM THE FLOOR. TYPICAL BOTH

DISPOSALS.

CONTRACTOR SHALL REPLACE EXISTING SINK WITH NEW

DOUBLE SINK IN NEW STAINLESS COUNTER. COUNTER SHALL

HAVE LIP AND BACKSPLASH. PHOTO OF EXISTING DOUBLE

SINK IN ROOM A350. SHOWN AS REFERENCE. SINK SHALL BE

INSTALLED WITH FAUCET AND SPRAYER FOR EACH SINK.

CABINETRY BELOW EXISTING SINK SHALL BE REMOVED, AND

FLOOR MOUNTED GARBAGE DISPOSAL SHALL BE INSTALLED.

CONTRACTOR SHALL INSTALL NEW SINK WITH

SPRAYER, EQUAL TO EXISTING SHOWN.

EXISTING FLOOR

MOUNTED DISPOSAL.

SHOWN AS

REFERENCE.

ALL NEW PIPING SHALL BE

PROVIDED IN COPPER AND WITH

FULLY ACCESSIBLE BALL TYPE

VALVE.

NOTE: NEW CLEANOUT SHALL BE

FURNISHED AND INSTALLED IN WALL IN

ACCESSIBLE SPACE DOWNSTREAM OF

GARBAGE DISPOSAL CONNECTION.

EXISTING DISPOSAL MODEL. SHOWN AS REFERENCE.

CONTRACTOR SHALL REPLACE EXISTING SINK WITH NEW

OVERSIZED SINGLE SINK IN NEW STAINLESS COUNTER.

COUNTER SHALL HAVE LIP AND BACKSPLASH. PHOTO OF

EXISTING OVERSIZED SINK IN ROOM A350. SHOWN AS

REFERENCE. SINK SHALL BE INSTALLED WITH SPRAYER.

CABINETRY BELOW EXISTING SINK SHALL BE REMOVED,

AND FLOOR MOUNTED GARBAGE DISPOSAL SHALL BE

INSTALLED.

CONTRACTOR SHALL INSTALL NEW SINK WITH

SPRAYER, EQUAL TO EXISTING SHOWN.

NOTE: NEW CLEANOUT SHALL BE

FURNISHED AND INSTALLED IN WALL IN

ACCESSIBLE SPACE DOWNSTREAM OF

GARBAGE DISPOSAL CONNECTION.

Scale

Date

Drawn By

Checked By

Project Number

National Center for Toxicological Research

Food and Drug Administration

3900 NCTR Road Jefferson, AR 72079

As indicated

3/

/2

:1 7:

A

M

A103

ROOM B114

RENOVATION

Checker Author

Issue Date Project Number

1/4" = 1'-0"

1 ROOM B114 RENOVATION

N.T.S.

2 REFERENCE PHOTO 1

N.T.S.

6 REFERENCE PHOTO 5

N.T.S.

3 REFERENCE PHOTO 2

N.T.S.

5 REFERENCE PHOTO 4

N.T.S.

7 REFERENCE PHOTO 6

NORTH

N.T.S.

4 REFERENCE PHOTO 3