18-Attachment B - Geotech.pdf
PDF 822 KB Posted
- Attached to
- North Himes Avenue at West Waters Avenue
- Solicitation number
- IFB-26-00271
- Issued by
- Hillsborough County, Florida
About this file
This is a Geotechnical Services Report prepared by Test Lab, Inc. for the Hillsborough County Engineering and Operations Department in Florida, supporting the design of intersection improvements at North Himes Avenue at West Waters Avenue. The report documents subsurface soil conditions and foundation design parameters for four proposed mast arm structures (Mast Arms 1-4) that will replace existing box span wire signal systems as part of the broader intersection improvement project. Standard Penetration Test (SPT) borings were advanced to approximately 40 feet below existing grade at each mast arm location, with field work conducted in September 2022. The study evaluated soil stratification, laboratory testing results, and provided equivalent single layer design parameters for drilled shaft foundation design at boring depths of 20, 25, and 30 feet.
The geotechnical investigation revealed general soil conditions consisting of loose to dense sand with silt (SP/SP-SM) and silty sand (SM) layers throughout the boring depths, with occasional limerock and cemented sand fragments. Design parameters provided include effective unit weights of 50 pounds per cubic foot, internal friction angles of 30 degrees, and zero cohesion values across all mast arm locations. The report recommends drilled shaft installation in accordance with Florida Department of Transportation Standard Specifications and advises that contractors anticipate temporary casing requirements due to loose soil conditions and potential concrete volume overruns during shaft installation. The contractor's dewatering equipment must be capable of handling artesian water up to elevation +30 feet NGVD, though artesian conditions were not encountered during field activities. The report was prepared by licensed professional engineers Connie A. Johnson-Gearhart and Igor (Igon) Kratser and digitally signed and sealed on September 16, 2022.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REPORT OF GEOTECHNICAL SERVICES
FOR MISCELLANEOUS STRUCTURES
NORTH HIMES AVENUE AT WEST WATERS AVENUE
INTERSECTION IMPROVEMENTS
HILLSBOROUGH COUNTY, FLORIDA
CIP NO. 69600102
TEST LAB PROJECT NO. GE-22-5276
Prepared for:
DRMP, INC.
15310 AMBERLY DRIVE, SUITE 200
TAMPA, FL 33647
Prepared by:
P.O. Box 15732 Tampa, Florida 33684
Florida Certificate of Authorization No. 1450
September 16, 2022
DRMP, Inc, 15310 Amberly Drive, Suite 200 Tampa, FL 33647
Attention: Mr. Steve Wallace, P.E.
Subject: Report of Geotechnical Services for Miscellaneous Structures North Himes Ave. at West Waters Ave. Intersection Improvements Hillsborough County, Florida CIP No: 69600102 Test Lab Project No: 22-5276
Dear Mr. Wallace:
Test Lab, Inc. (Test Lab) has performed a geotechnical study for the proposed miscellaneous structures associated with this project. This report presents the findings of our field exploration, results from laboratory testing and recommended soil parameters for use in the design of the proposed structures.
Test Lab appreciates the opportunity of providing our services to the Florida Department of Transportation (FDOT) on this project. If there are any questions concerning this report, or if we may be of any further assistance, please do not hesitate to contact us.
Respectfully submitted, Test Lab, Inc.
4112 West Osborne Avenue, Tampa, Florida 33614 Florida Certificate of Authorization No. 1450
Connie A. Johnson-Gearhart, P.E.
Geotechnical Engineer Florida License No. 69013
Igor (Igon) Kratser, P.E.
Senior Geotechnical Engineer Florida License No. 73129
Copies Submitted: (1) Client
This item has been digitally signed and sealed by Igor (Igon) Kratser, P.E. on the date adjacent to the seal.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
TABLE OF CONTENTS
PROJECT INFORMATION
STRUCTURE LOCATIONS
SOIL BORINGS AND GENERAL SOIL CONDITIONS
Soil Borings
General Soil Conditions
FOUNDATION EVALUATIONS AND RECOMMENDATIONS
Shaft Installation
Shaft Embedment/Length
Equivalent Single Layer Design Parameters
LIMITATIONS
APPENDIX A
Report of Core Borings (Sheet 1)
Report of Geotechnical Services for Miscellaneous Structures Hillsborough County, Florida North Himes Ave. at West Waters Ave. Intersection Improvements Test Lab Project No. GE-22-5276
PROJECT INFORMATION
The purpose of this study is to support the design of the proposed miscellaneous structures planned as a part of the improvements at the referenced intersection in Hillsborough County, Florida. The miscellaneous structure foundation type evaluated in this report includes mast arms at the locations summarized below.
STRUCTURE LOCATIONS
The following table summarizes the proposed miscellaneous structure, foundation type and location information.
Structure/ Foundation
Type
Approximate Structure Location (Station, Offset)*
Reference Boring No.
Mast Arm No. 1/ Drilled Shaft
46+31, 57’LT MA 1
Mast Arm No. 2/ Drilled Shaft
47+27, 64’ LT MA 2
Mast Arm No. 3/ Drilled Shaft
47+29, 61’ RT MA 4
Mast Arm No. 4/ Drilled Shaft
46+45, 71’ RT MA 3
*Referenced from B/L Survey W. Waters Ave.
SOIL BORINGS AND GENERAL SOIL CONDITIONS
Soil Borings
The subsurface conditions at the proposed structure locations were evaluated utilizing Standard
Penetration Test (SPT) borings advanced to depths of approximately 40 feet below existing grade. The borings performed were located in the field by a representative of Test Lab using handheld Global
Positioning System (GPS) devices and measuring distances from existing site features. The boring locations and elevation were determined using MicroStation design files provided by the design team in conjunction with the recorded GPS coordinates obtained by Test Lab in the field at the boring location. The boring locations are illustrated on the Report of Core Borings Sheets in Appendix A.
The SPT borings were performed with the use of a drill rig using Bentonite Mud drilling procedures. The soil sampling was performed in general accordance with American Society for Testing and Materials
(ASTM) test designation D-1586 titled “Penetration Test and Split-Barrel Sampling of Soils”. The upper 2 to 6 feet of the borings were excavated by hand to verify utility clearance. SPT N-values were then taken continuously to a depth of 10 feet and at intervals of 5 feet thereafter. Representative portions of these soil samples were sealed in glass jars, labeled, and transferred to our Tampa laboratory for classification and analysis.
General Soil Conditions
The SPT borings generally encountered layers of loose to dense sand to silty sand (SP/SP-SM) and loose to dense silty sand (SM) to the boring completion depths of 40 feet. Occasionally, limerock fragments and cemented sand fragments were encountered and when a discernable amount was observed, was noted adjacent to the sample interval on the Report of Core Borings Sheet.
Soil stratification was determined based on a review of recovered samples, laboratory test results, and interpretation of field boring logs. Stratification lines represent approximate boundaries between soil layers of different engineering properties; however, actual transitions between layers may be gradual. In some cases, small variations in properties that were not considered pertinent to our engineering evaluation may have been abbreviated or omitted for clarity. The soil profiles represent the conditions at the boring locations and variations do occur among the borings. Specific details about subsurface conditions and materials encountered at each test location can be obtained from the soil profiles presented on the Report of Core
Borings Sheet in Appendix A.
FOUNDATION EVALUATIONS AND RECOMMENDATIONS
Shaft Installation
The drilled shaft foundations should be installed in accordance with the FDOT Standard Specifications for
Road and Bridge Construction (SSRBC), latest edition.
Due to the loose/soft conditions of the soils in some areas, the contractor should anticipate the need for temporary casing to stabilize the excavation during construction. In addition, the contractor should anticipate that concrete volume overruns may occur during the shaft installation process.
Based on review of the Potentiometric Surface Maps, published by Southwest Water Management
District, September 2017, the potentiometric elevation of the upper Floridan Aquifer at the referenced intersection is reported to be between approximately +20 TO +30 NGVD29. Artesian conditions were not encountered at the time of our field activities. However, the contractor’s dewatering equipment and methods shall be adequate to handle artesian water up to head elevation of +30 feet, NGVD.
Shaft Embedment/Length
If the proposed structure foundations are to be installed within berms or embankments with side slopes steeper than 4H:1V, the foundation designer should include the portion of the shaft with less than 2.5D
(D=Shaft Diameter) horizontal soil cover (face-of-shaft to face-of slope) in the unsupported length, and design the portion of the shaft with more than 2.5D horizontal soil cover as though embedded through level ground.
Equivalent Single Layer Design Parameters
Test Lab has provided equivalent single layer design parameters to be used for design of drilled shaft foundations based on the soil strata encountered within the SPT borings. The equivalent single layer design parameters are presented below.
Boring # Boring Depth
(ft)
EQUIVALENT SINGLE LAYER DESIGN
PARAMETERS
Effective Unit
Weight (pcf)
Internal Friction Angle
(Degrees)
Cohesion/Shear Strength
(psf) Navg*
MA-1
20 50 30 0 11
25 50 30 0 15
30 50 30 0 18
MA-2
20 50 30 0 12
25 50 30 0 14
30 50 30 0 15
MA-3
20 50 30 0 10
25 50 30 0 10
30 50 30 0 10
MA-4
20 50 30 0 9
25 50 30 0 10
30 50 30 0 12
*Navg taken to sample increment at or below the shaft length.
It is our understanding that the design team will design the proposed structure foundation sizes and embedment depths using the FDOT Mathcad programs and/or FDOT Standard Indices. The designer should consider the difference in elevations between the borings (if applicable) and the proposed foundation when reviewing the recommended soil parameters.
LIMITATIONS
Our professional services have been performed, our findings obtained, and our recommendations prepared in accordance with generally accepted geotechnical engineering principles and practices at the time of this report. Test Lab is not responsible for the conclusions, opinions or recommendations made by others based on this data.
The scope of the exploration was intended to evaluate soil conditions within the influence zone of the structure foundations. The soil parameters and recommendations submitted in this report are based upon the data obtained from the soil borings performed at the locations indicated. If any subsoil variations become evident during the course of this project, a re-evaluation of the recommendations contained in this report will be necessary after we have had an opportunity to observe the characteristics of the condition encountered. The applicability of the report should also be reviewed in the event significant changes occur in the design, nature, or location of the proposed structures.
The scope of our services does not include any environmental assessment or investigation for the presence or absence of hazardous or toxic materials in the soil, groundwater, or surface water within or beyond the site studied. Any statements in this report regarding odors, staining of soils, or other unusual conditions observed are strictly for the information of our client.
APPENDIX A
Report of Core Borings (Sheet 1)
45 P R
C
S
T A .4
.7
36" RCP
36" RCP
30" RCP
18" RCP
18" RCP
36" RCP
15" PVC
18" RCP
15" PVC
DUMPSTER
42"
SWK PAD
SWK PAD
LANDSCAPE
SWK PAD
SWK PAD
SWK PAD
SWK PAD
LANDSCAPE
SWK PAD
LANDSCAPE
LANDSCAPE
3" METAL
SWK PAD
TRAFFIC DETECTOR
SWK PAD
LANDSCAPE
LANDSCAPE
TRAFFIC DETECTOR
SWK PAD
LANDSCAPE
LANDSCAPE
LANDSCAPE
SWK PAD
LANDSCAPE
LANDSCAPE
SWK PAD
TRAFFIC DETECTOR
TRAFFIC DETECTOR
ELEC
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
asphalt
OUTLET
TRAFFIC SIGNAL
DUMPSTER
TRAFFIC DETECTOR
asphalt
TRAFFIC DETECTOR
TRAFFIC DETECTORTRAFFIC DETECTORTRAFFIC DETECTOR
GAS
TRAFFIC DETECTOR
WATER
TRAFFIC DETECTOR
asphalt
UNDERGROUND CABLE
asphalt
SD
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
WATER
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
UNITI FIBER
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC SIGNAL
TRAFFIC DETECTOR
TRAFFIC SIGNAL
SAN
TRAFFIC DETECTOR
TRAFFIC DETECTOR
WATER
TRAFFIC DETECTOR
GAS
TRAFFIC DETECTOR
TRAFFIC SIGNAL
TRAFFIC DETECTOR
WATER
TRAFIC
TRAFFIC DETECTOR
TRAFIC
START VERIZON
BURIED CABLE
VERIZON
TRAFFIC DETECTOR
TRAFFIC DETECTORTRAFFIC DETECTOR
WATER
UNKN
WATER
VERIZON
CL VERIZON
WATER
1" PVC PIPE 30" TALL
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFFIC SIGNAL
WATER
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
NETWORK
TRAFFIC DETECTORTRAFFIC DETECTOR
TRAFFIC DETECTOR
THERE ARE 2 OF THEM 6"X6" CONC
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTORTRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
TRAFFIC DETECTOR
MISC PAVEMENT
C O
N C
R E
T E
S
ID
E W
A L
K
ASPHALT
PAVEMENT
TWIN
18"
6X6X6 W/LIFT STATION6X6X6 W/LIFT STATION
U
UNK
APRON
CONCRETE
PAVEMENT
ASPHALT
50"
U
CONCRETE SIDEWALK
APRON
CONCRETE
UNKNOWN
VALVE
C H
A
IN
L
IN
K
F E
N C
E
SIDEWALK
CONCRETE
42"
9/16/2022 T:\Word\documents\Ge\GE Projects\2022 Projects\22-5276 Himes at Waters Intersection\micro\SPTBSG_BoringLocations_01.dgn5:08:41 PM
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602 69600102
CIP NO. SHT. NO.
T H
E
O F
F I
C I
A L
C O
D
O
T
I
S
E E
T
T
E C
T R
O N
C
G I
T A
L
Y
G N
A N
A L
U N
D
U
L E
G
A
C
CAPITAL PROGRAMS DEPARTMENT
REPORT OF CORE BORINGS
HIMES AVENUE AT WATERS AVENUE
09/12/2022
STA.:
DRILLER:
BOR #:
ELEV.:
DATE:
OFF.:
HAMMER: AUTO
LAT.:
LONG.:
REF.:
45.8
MA-01
N
HA
HA
M. HERNANDEZ
HA
GNA
46+31
57' LT
£ SURVEY W WATERS AVE
09/14/2022
STA.:
DRILLER:
BOR #:
ELEV.:
DATE:
OFF.:
HAMMER: AUTO
LAT.:
LONG.:
28.025607°
REF.:
46.3
MA-02
-82.500617°
N
M. HERNANDEZ
47+27
64' LT
£ SURVEY W WATERS AVE
09/12/2022
STA.:
RIG:
DRILLER:
BOR #:
ELEV.:
DATE:
OFF.:
HAMMER: AUTO
LAT.:
LONG.:
28.025230°
REF.:
46.6
MA-03
-82.500856°
N
M. HERNANDEZ
46+45
71' RT
£ SURVEY W WATERS AVE
D50
09/14/2022
STA.:
RIG:
DRILLER:
BOR #:
ELEV.:
DATE:
OFF.:
HAMMER: AUTO
LAT.:
LONG.:
28.025264°
REF.:
47.7
MA-04
-82.500599°
N
M. HERNANDEZ
47+29
61' RT
£ SURVEY W WATERS AVE
28.025579°
-82.500915°
HA
HA
HA
HA
HA
HA
MC = 23.4
-200 = 2.8
MC = 28.8
-200 = 7.3
MC = 28.7
-200 = 5.9
SILTY SAND (SM)
TO DARK BROWN TO GRAY
GRAYISH BROWN TO BROWN
SILTY SAND (SM)
TO DARK BROWN TO GRAY
GRAYISH BROWN TO BROWN
WITH SILT (SP/SP-SM)
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
FRAGMENTS (SP/SP-SM)
WITH SILT WITH LIMEROCK
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
FRAGMENTS (SP/SP-SM)
WITH SILT WITH LIMEROCK
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
WITH SILT (SP/SP-SM)
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
FRAGMENTS (SM)
WITH CEMENTED SAND
TO GRAY SILTY SAND
BROWN TO DARK BROWN
GRAYISH BROWN TO
SILTY SAND (SM)
TO DARK BROWN TO GRAY
GRAYISH BROWN TO BROWN
(SP/SP-SM)
SAND WITH SILT
VERY DARK GRAY SAND TO
BROWN TO LIGHT GRAY TO
TO VERY DARK GRAYISH
BROWN TO GRAYISH BROWN
PALE BROWN TO VERY DARK
SILTY SAND (SM)
TO DARK BROWN TO GRAY
GRAYISH BROWN TO BROWN
BR 2500
2B
2B
2B
2B
MC = 32.5
-200 = 10.0
WITH SILT (SP/SP-SM)
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
WITH SILT (SP/SP-SM)
VERY DARK GRAY SAND TO SAND
GRAYISH BROWN TO LIGHT GRAY TO
TO GRAYISH BROWN TO VERY DARK
PALE BROWN TO VERY DARK BROWN
-200
MOISTURE CONTENT (%)MC
LL LIQUID LIMIT (%)
PL
PI
PLASTIC LIMIT (%)
PLASTICITY INDEX (%)
GROUNDWATER TABLE AT TIME OF DRILLING
(SP)
N
NORTH AMERICA VERTICAL DATUM OF 1988NAVD 88
STANDARD SIEVE (%)
FINES PASSING THE #200
LEGEND
£ BASELINE OF SURVEY
GNA
ELEV. 5.0
APPROXIMATE LOCATION OF SPT BORING
(NAVD 88) AT TEST LOCATION
APPROXIMATE GROUND SURFACE ELEVATION
NOTED)
FOR 12 INCHES OF PENETRATION (UNLESS OTHERWISE
NUMBER TO THE LEFT OF BORING INDICATES SPT VALUE
DARK GRAY SAND TO SAND WITH SILT (SP/SP-SM)
TO VERY DARK GRAYISH BROWN TO LIGHT GRAY TO VERY
PALE BROWN TO VERY DARK BROWN TO GRAYISH BROWN
GROUP SYMBOL AS DETERMINED BY VISUAL REVIEW
UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D 2488)
INTRODUCTION OF DRILLING FLUID AT A DEPTH OF 10 FEET
GROUNDWATER TABLE NOT APPARENT DUE TO THE
HA HAND AUGERED TO VERIFY UTILITY CLEARANCE
SILTY SAND (SM)
GRAYISH BROWN TO BROWN TO DARK BROWN TO GRAY
NOTES:
NOTE:
THE FIELD.
COORDINATES OBTAINED BY TEST LAB, INC. IN
PROJECT MICROSTATION FILES ALONG WITH GPS
AND LONGITUDE WERE DETERMINED USING
BORING ELEVATION, STATION, OFFSET, LATITUDE
ADDITION, THE CONTRACTOR SHOULD ANTICIPATE THAT CONCRETE VOLUME OVERRUNS MAY OCCUR DURING THE SHAFT INSTALLATION.
CONTRACTOR SHOULD ANTICIPATE THE NEED FOR TEMPORARY CASING TO STABILIZE THE EXCAVATION DURING CONSTRUCTION. IN
2. DUE TO THE LOOSE/SOFT CONDITIONS OF THE SOILS ENCOUNTERED WITHIN THE BORING DEPTHS IN SOME AREAS, THE
+30 FEET, NGVD.
CONTRACTOR'S DEWATERING EQUIPMENT AND METHODS SHALL BE ADEQUATE TO HANDLE ARTESIAN WATER UP TO THE ELEVATION OF
FEET NGVD 29 OR LESS. ARTESIAN CONDITIONS WERE NOT ENCOUNTERED AT THE TIME OF OUR FIELD ACTIVITIES. HOWEVER, THE
POTENTIOMETRIC ELEVATION OF THE UPPER FLORIDAN AQUIFER WITHIN PROJECT AREA IS REPORTED AT APPROXIMATELY +20 TO +30
1. BASED ON REVIEW OF THE POTENTIOMETRIC SURFACE MAPS, PUBLISHED BY SOUTHWEST WATER MANAGEMENT DISTRICT, THE
N
Feet
100200
4112 WEST OSBORNE AVENUE
TAMPA, FL 33614
IGOR (IGON) KRATSER, P.E.
P.E. LICENSE NUMBER 73129
TEST LAB, INC.
SOIL PROFILES
MA-02
MA-04
MA-03
MA-01
£ SURVEY W WATERS AVE
TEST LOCATION PLAN
RIG:
E L E
V A
T I O
N
I N
F
E E
T
(N
A V
D
D50
RIG:
E L E
V A
T I O
N
I N
F
E E
T
(N
A V
D
BR 2500
(BLOWS/FT.)
SPT N-VALUE
VERY LOOSE
LOOSE
DENSE
VERY DENSE
RELATIVE DENSITY
GRANULAR MATERIALS-
MEDIUM DENSE
24 to 40
8 to 24
LESS THAN 3
GREATER THAN 40
3 to 8
AUTOMATIC HAMMER
(BLOWS/FT.)
SPT N-VALUE
HARD
VERY STIFF
STIFF
SILTS AND CLAYS
CONSISTENCY
FIRM
SOFT
VERY SOFT
12 to 24
6 to 12
GREATER THAN 24
LESS THAN 1
3 to 6
1 to 3
| 2022-09-16T17:18:34-0400 | |
| Igor Kratser |
File details come from the government source that posted it. Updated .