160214 -Addendum # 2 Revised.pdf Signed.pdf
PDF 4 MB Posted
- Attached to
- 160214 Dillwyn AHQ Combo Building Fuel Facility
- Solicitation number
- IFB-113890
- Issued by
- Buchanan County, Virginia
About this file
This is Addendum No. 2 issued by the Virginia Department of Transportation (VDOT) to the Invitation for Bids for the Dillwyn Area Headquarters Combo Building & Fuel Facility project, located at 147 Thomas Road, Dillwyn, Virginia. The project involves construction of a single-story, approximately 4,998 square foot structure featuring precast architectural concrete masonry exterior walls, pre-engineered wood truss roof framing, and architectural grade shingle roofing. The facility will include approximately 2,416 square feet of administrative office space with staff offices, meeting room, restrooms, locker room, utility room, and storage, plus two vehicle storage and maintenance bays totaling approximately 2,582 square feet. The original prebid conference was scheduled for March 5, 2026. Addendum No. 2, dated March 23, 2026, revises critical bidding deadlines: the bid submission deadline is extended to 2:00 P.M. EST on April 2, 2026, and the public bid opening is rescheduled to 2:00 P.M. EST on April 3, 2025. Acknowledgement of this addendum must accompany the bid submission, or the bid may be declared non-responsive. The addendum includes six pages of questions and answers addressing clarifications on project specifications and drawings, modifications to electrical site plans, panel schedules, grounding details, and site adaptive typical details.
The addendum provides technical clarifications on multiple project components, including specifications for an aluminum interior sliding service window with tempered glass glazing, exterior concrete equipment pad details, epoxy paint specifications for concrete masonry unit walls per MPI standards, solid surface countertops with Class A finish material and NSF/ANSI 51 certification, and electrical panel options. A critical clarification addresses the responsibility for existing fuel facility demolition and removal: VDOT will remove and relocate only the existing fabric canopy, while the Contractor is responsible for removing all other existing fuel facility components including dispensers, barrier walls, concrete, oil house, and underground fuel tanks with proper offsite disposal. Lightning protection system requirements are detailed to meet UL96A, NFPA 70, and NFPA-780 standards, with the Contractor required to provide a UL Master Label Certificate at project closeout. All contractors must acknowledge receipt of this addendum and any subsequent addenda prior to the bid due date and time.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF TRANSPORTATION
Stephen C. Brich, P.E. 1221 E Broad Street Tel: (804) 482-5818
Commissioner Richmond, Virginia 23219
March 23, 2026
ADDENDUM NO. 2 TO ALL BIDDERS:
Reference – Invitation For Bids:
Commodity:
Dated:
Project Code:
For Delivery To:
Bids Due:
Prebid Conference:
160214 Dillwyn AHQ Combo Building & Fuel Facility February 18, 2026 501-18130-087 Commonwealth of Virginia Department of Transportation March 26, 2026 (changed below) March 05, 2026
The above is hereby changed to read:
1. Reference 160214 Project Manual DGS 30-256, Bid Due Date: Change to read “The deadline for submitting bids is 2:00 P.M. EST, as determined by the bid officer, on April 2, 2026."
2. Reference 160214 Project Manual DGS 30-256, Bid Opening Date: Changed to read “The bids will be opened publicly and read aloud beginning at 2:00 P.M EST on April 3, 2025."
3. Reference Addendum #2 (Two) document attached: Sealed by Brian E. Goldman of Architectural Partners (6 pages) with Questions and Answers to include changes to Specifications and Drawings.
Note: Acknowledgement of this addendum or any subsequent addenda must be prior to the bid due date and time or signed and uploaded as an attachment with the electronic bid submission. Failure to acknowledge or submit the addendum may be grounds for declaring the bid non-responsive.
Sincerely, Kareem Rahman Contract Officer kareem.rahman@vdot.viginia.gov
Name of Firm
Signature Title Date
10 9th S treet , Lynchburg , Vi rginia 24504 p 434-846-8456 | f 434-846-4534 | www.archi tecturalpar tners.com
A d d e n d u m
PROJECT INFORMATION
OWNER NAME: VIRGINIA DEPT. OF TRANSPORTATION OWNER PROJECT MGR: JOHN DYER
PROJECT TITLE:
VDOT – DILLWYN AHQ – COMBO
BUILDING & FUEL FACILITY
OWNER PROJECT NO.: 501-18130-087
A/E PROJECT MGR.: BRIAN E. GOLDMAN, RA
PROJECT LOCATION: 147 THOMAS ROAD, DILLWYN, VA BIDS DUE: REFER TO VDOT ADDENDUM
IFB NO.: 160214 BID OPENED: COVER LETTER
ADDENDUM #: 2
This addendum becomes part of the Construction Documents. The following changes, additions, and deletions shall be made to the following documents; all other conditions shall remain the same. Please attach to all copies of the Construction Documents which you are holding.
All Contractors are to state in their bid the receipt of this addendum. Instructions to Bidders:
ADDENDUM TO THE DRAWINGS – DRAWINGS:
Number Drawing Detail No.
2S1.0 ALL SITE ADAPTIVE TYPICAL DETAILS
1E1.1
PANEL SCHEDULE &
GROUNDING
A DETAIL
2E1.0 ELECTRICAL SITE PLAN NOTES #4 & #12
ADDENDUM TO THE PROJECT MANUAL VOLUME 1 & 2
Number
Spec Section
Specification Change
No changes to Specification Sections
QUESTIONS/ANSWERS AND CLARIFICATIONS:
Number
A2Q1 Question Please provide specifics for interior sliding window shown on sheet A9, detail A.
Answer Provide aluminum, medium-duty interior sliding service window. Refer to Drawing
A9 for size.
• Frame shall be constructed of 6063-T5 extruded aluminum, with overhead track, side jambs, and two framed window sections.
• Each window frame rolls on bottom-mounted heavy-duty ball bearing wheels that ride on aluminum lower channels recessed into solid surface shelf. Provide manufacturer’s standard catch locks.
• Aluminum finish will be selected as part of the submittal process.
http://www.architecturalpartners.com/
• Glazing shall be 1/4" clear tempered glass.
A2Q2 Question There is no detail for exterior concrete equipment pads on sheet C501, however, there is a detail on sheet M4. Advise if this detail is to be used for all exterior concrete equipment pads.
Answer See attached Sheet #2S1.0 SITE ADAPTIVE TYPICAL DETAILS
A2Q3 Question Drawing A1 indicates epoxy paint to be used for CMU walls in Room 113. No
Specification for epoxy paint exists in project documents. Provide specification for epoxy paint.
Answer Refer to Specification Section 099123 Interior Painting for submittals, maintenance materials, mockups, delivery / storage, field conditions, and preparation information.
Part 2 PRODUCTS
2.1 BLOCK FILLERS
A. Epoxy Block Filler: Solvent-based, two-component, epoxy, high-solids coating;
formulated to bridge and fill porous surfaces of CMU substrates in preparation for specified subsequent coatings.
2.2 INTERIOR HIGH-PERFORMANCE COATING SCHEDULE, MASONRY
SUBSTRATES
A. CMU Substrates:
1. Epoxy System for Wet Environments: MPI INT 4.2G.
a. Block Filler: Epoxy block filler, MPI #116.
b. Intermediate Coat: Epoxy, matching topcoat.
c. Topcoat: Epoxy, gloss, MPI #77.
A2Q4 Question Please provide a level/class of finish for the Solid Surface Countertops. Currently finish is not specified.
Answer Refer to specification section 123661.16 2.1.
Colors and patterns are to be selected by the A/E from the manufacturer’s full range.
The solid surface material is to be Class A Finish Material and NSF/ANSI 51
Certified.
A2Q5 Question On electrical drawing E5 plan options are shown. Clarify how to deal with these options.
Answer The Contractor is directed on the inclusion of options by note 2 on sheet 2C1.0.
Therefore, Options 1, 2, 3 & 5 (as shown on E5) are not applicable to this project
A2Q6 Question It was stated in the Pre-Bid conference that the existing fuel facility, canopies, concrete and tanks would be removed by VDOT or VDOT Contractor. No addendum has been issued regarding this verbal direction.
Answer VDOT will remove and relocate the existing fabric canopy only. All other existing fuel facility components including, but not limited to the dispensers, barrier walls, concrete, oil house and underground fuel tanks will be removed and properly disposed of offsite by the Contractor. VDOT reserves the option to remove any remaining fuel from the tanks prior to demolition.
END OF ADDENDUM
03/20/2026
CANOPY ROOF
1 1
GROUND INSPECTION WELL
GROUND ROD (TYP OF 4)
COLUMN, TYPICAL
2 2
FI-1
NOTE: COLUMNS ARE SHOWN OVERSIZED FOR CLARITY AND ARE NOT TO SCALE.
7 7
6 6
A 1E1.1 1E1.1
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
_3/
/2
:5 9:
A
M
2025-06-13
BID SET
434-846-1350 Fax: 434-846-1351 904 Lakeside Drive, Lynchburg, VA 24501
423-331
PR
OJ
EC
T
NO
V D
O T
D
IL
LW
Y
N A
R
EA
H
EA
D Q
U A
R
TE
R S
CO
M
BI
NA
TI
ON
B
UI
LD
IN
G
FU
EL
C
EN
TE
R
TH
O
M A
S R
O A
D
IL
LW
Y N
, V A
PR
OJ
EC
T
CO
DE
:5
-1
-0
1E1.1
SCALE: NONE SCALE: NONE
XX
FUEL STATION CANOPY - LIGHTING & LIGHTNING PROTECTION PLAN
NORTH
A 1E1.1 1E1.1
DETAIL
NAV/MGB
NAV
MGB
ADDENDUM 2: 2026-03-19
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text Q
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text G
AutoCAD SHX Text
(TYP OF 8)
AutoCAD SHX Text H
AutoCAD SHX Text
FUEL STATION PANEL SCHEDULE AND GROUNDING
AutoCAD SHX Text
GROUND INSPECTION WELL
AutoCAD SHX Text
GROUND INSPECTION WELL
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
WELL COVER
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text
3/4" X 10' COPPERCLAD STEEL
AutoCAD SHX Text
IPC #579
AutoCAD SHX Text
ROBBINS #97-10
AutoCAD SHX Text
THOMPSON #TL3410
AutoCAD SHX Text
VFC #3410
AutoCAD SHX Text
GROUND ROD
AutoCAD SHX Text C
AutoCAD SHX Text
COPPER BRONZE FOR CONNECTING ONE OR TWO HORIZONTAL
AutoCAD SHX Text
IPC #28U
AutoCAD SHX Text
ROBBINS #99A
AutoCAD SHX Text
THOMPSON #493
AutoCAD SHX Text
VFC #305
AutoCAD SHX Text
CABLES THROUGH 2/0 TO ANY SIZE GROUND ROD THROUGH 3/4".
AutoCAD SHX Text
AND CABLE CLAMP
AutoCAD SHX Text
PERPENDICULAR GROUND ROD
AutoCAD SHX Text M
AutoCAD SHX Text 10'-0" x 3/4" DIA COPPER
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
GROUND ROD (TYPICAL)
AutoCAD SHX Text
EXOTHERMIC CONNECTION
AutoCAD SHX Text
BONDED
AutoCAD SHX Text
DETAIL-EXOTHERMIC CONNECTION WIRE TO GROUND ROD
AutoCAD SHX Text Q
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
(TYPICAL)
AutoCAD SHX Text
DETAIL-EXOTHERMIC CONNECTION WIRE TO WIRE
AutoCAD SHX Text S
AutoCAD SHX Text
LIGHTNING PROTECTION
AutoCAD SHX Text
CABLE
AutoCAD SHX Text E
AutoCAD SHX Text
17 GAUGE STRANDS, 57,400 CIRCULAR MILS CROSS-
AutoCAD SHX Text
SECTION, WEIGHT PER LENGTH 187 LB/1000 FEET.
AutoCAD SHX Text
MUST BE COPPER UNDERGROUND.
AutoCAD SHX Text
SMOOTH TWIST COPPER CABLE
AutoCAD SHX Text
1/2" X 24" LONG SOLID ALUMINUM
AutoCAD SHX Text
IPC #A331
AutoCAD SHX Text
ROBBINS #A24
AutoCAD SHX Text
THOMPSON #A55
AutoCAD SHX Text
VFC #1212ALAT
AutoCAD SHX Text
AIR TERMINAL
AutoCAD SHX Text H
AutoCAD SHX Text
24 STRAND, 14 GAUGE CABLE, 98,500 CIRCULAR MILS.
AutoCAD SHX Text
IPC #A24
AutoCAD SHX Text
ROBBINS #A3
AutoCAD SHX Text
THOMPSON #A24
AutoCAD SHX Text
VFC #A24S
AutoCAD SHX Text
SMOOTH TWIST ALUMINUM CABLE
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text D
AutoCAD SHX Text G
AutoCAD SHX Text
1. EXOTHERMIC WELD #1/0 BCSD TO COLUMN. EXOTHERMIC WELD #1/0 BCSD TO COLUMN. 2. #1/0 BCSD GROUND LOOP. #1/0 BCSD GROUND LOOP. 3. PROVIDE 3 AIR TERMINALS EACH SIDE, TOTAL OF 8. PROVIDE 3 AIR TERMINALS EACH SIDE, TOTAL OF 8. 4. PROVIDE SURFACE MOUNTED, LED LIGHT FIXTURE, WET-LOCATION LISTED PROVIDE SURFACE MOUNTED, LED LIGHT FIXTURE, WET-LOCATION LISTED IP66, SQUARE OR RECTANGULAR, MAXIMUM DEPTH (HEIGHT) OF LIGHT FIXTURE SHALL BE 4", 530 mA DRIVE CURRENT, 5000K COLOR TEMP, WIDE DISTRIBUTION, -40 DEGREES FAHRENHEIT, THERMOSET POWDER COAT. TYPICAL OF 4. SURFACE MOUNT UNDER CANOPY. 5. ROUTE ALL RACEWAY, WIRE, CONDUIT, AND LIGHTNING PROTECTION IN THE ROUTE ALL RACEWAY, WIRE, CONDUIT, AND LIGHTNING PROTECTION IN THE CANOPY COLUMNS. COORDINATE ACCESS WITH CANOPY MANUFACTURER AND INSTALLER. 6. PROVIDE 10' LONG LIGHTNING ROD CLAMPED NEAR BOTTOM AND TOP OF PROVIDE 10' LONG LIGHTNING ROD CLAMPED NEAR BOTTOM AND TOP OF BOTH FUEL STATION VENT PIPES WITH TOP OF LIGHTNING ROD A MINIMUM OF 5' ABOVE THE TOP OF EACH VENT. REFER TO DETAIL A THIS SHEET. 7. ROUTE ALUMINUM LIGHTNING PROTECTION CABLE ABOVE ROOF TO ROUTE ALUMINUM LIGHTNING PROTECTION CABLE ABOVE ROOF TO COLUMN. TRANSITION TO COPPER CABLE. ROUTE COPPER DOWN COLUMN AND CONNECT TO COUNTERPOISE LOOP. 8. COORDINATE WITH MECHANICAL CONTRACTOR FOR VENT LOCATION. COORDINATE WITH MECHANICAL CONTRACTOR FOR VENT LOCATION. 9. SEE SHEET E4 FOR LOCATION OF TMS PANEL WITHIN COMBO BUILDING SEE SHEET E4 FOR LOCATION OF TMS PANEL WITHIN COMBO BUILDING ROOM 104. 10. SEE SHEET 2E1.0 FOR LOCATION OF LOAD.SEE SHEET 2E1.0 FOR LOCATION OF LOAD.
AutoCAD SHX Text
1. ALL RACEWAY FOR LIGHTING SHALL BE CONCEALED. ALL RACEWAY FOR LIGHTING SHALL BE CONCEALED. 2. LIGHT FIXTURES SHALL BE REMOVABLE WITHOUT ACCESS INTO THE LIGHT FIXTURES SHALL BE REMOVABLE WITHOUT ACCESS INTO THE CANOPY ENCLOSURE. 3. JUNCTION BOXES FOR LIGHT FIXTURE WIRING SHALL BE ACCESSIBLE JUNCTION BOXES FOR LIGHT FIXTURE WIRING SHALL BE ACCESSIBLE WHEN LIGHT FIXTURES ARE REMOVED. PROVIDE ACCESS PANELS AS REQUIRED. 4. COORDINATE CANOPY TO ALLOW ELECTRICAL RACEWAY FOR POWER AND COORDINATE CANOPY TO ALLOW ELECTRICAL RACEWAY FOR POWER AND LIGHTNING PROTECTION TO RUN THROUGH FOUNDATION, COLUMN, AND PENETRATE ROOF. 5. THE LIGHTNING PROTECTION SYSTEM SHALL MEET REQUIREMENTS OF UL96A, THE LIGHTNING PROTECTION SYSTEM SHALL MEET REQUIREMENTS OF UL96A, NFPA 70 & NFPA-780 LIGHTNING PROTECTION SYSTEM STANDARDS. THE DESIGN LAYOUT AND INSTALLATION DETAILS SHOWN HEREON ARE DIAGRAMMATIC AND MAY NOT SHOW ALL THE COMPONENTS AND HARDWARE. THE SYSTEM INSTALLER MUST PROVIDE ADDITIONAL HARDWARE AND INSTALLATION MEANS TO MEET THESE REQUIREMENTS. CONTRACTOR SHALL PROVIDE UL MASTER LABEL CERTIFICATE FOR THE SYSTEM AT PROJECT CLOSE-OUT. 6. CONNECTIONS TO GROUND RODS OR GROUND LOOP SHALL BE MADE AT A POINT CONNECTIONS TO GROUND RODS OR GROUND LOOP SHALL BE MADE AT A POINT NOT LESS THAN 1'-6" BELOW FINISHED GRADE AND A MINIMUM OF 2'-0" AWAY FROM FOUNDATION WALL. 7. AIR TERMINALS SHALL BE PLACED AT ALL UNPROTECTED OUTSIDE EDGES OF AIR TERMINALS SHALL BE PLACED AT ALL UNPROTECTED OUTSIDE EDGES OF ROOF STRUCTURES WITHIN 2'-0" OF OUTSIDE EDGE PERIMETER. 8. ALL LIGHTNING CONDUCTORS SHALL BE FASTENED NOT MORE THAN 3-0" ALL LIGHTNING CONDUCTORS SHALL BE FASTENED NOT MORE THAN 3-0" MAXIMUM SPACING WITH FASTENERS OF APPROPRIATE TYPE BASED ON ROOF CONSTRUCTION TYPE.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NONE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
CONSTRUCTION NOTES
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text 4'
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
DETAIL - EXOTHERMIC WELD TO
AutoCAD SHX Text
COLUMN
AutoCAD SHX Text
LIGHTNING PROTECTION CABLE
AutoCAD SHX Text
2' AIR TERMINAL
AutoCAD SHX Text
10' SUPPORT
AutoCAD SHX Text
CONCRETE SLAB
O H
E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E O
H E
O H
E
U G
E U
G E
U G
E
FO
TE
L
W
W
W
W
W
W
W
W
W
W
W W
W
W W W
CO
W
W
U G
E
U G
E
U G
E
UG T UG T
UG T
UG T
UG G
UG G UG G
M
AR
K
TE
L
W V
M
W
W
W
W
CLEANOUT
SSSSCO
EV
VI
SI
TO
R
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X X
X X
X
X
U G
E
UG
E
UG
E
UG E
UG E
UG
E
U G
E U
G E
U G
E
UG E
UG E UG E UG E UG E
UG E
UG E UG E UG E UG E
U G
E U
G E
UG E UG E
UG E
UG E
U G
E U
G E
U G
E
B 2E2.12E1.0
D 2E2.12E1.0
B 2E2.12E1.0
A 2E2.12E1.0
C 2E2.12E1.0
C 2E2.12E1.0
B 2E2.12E1.0
A 2E2.22E1.0
UG
E
B 2E2.02E1.0
B 2E1.02E1.0
A 2E1.0 2E2.0
2E1.0
ELECTRICAL SITE PLAN
ELECTRICAL SITE PLAN
NORTH
SITE LIGHTING FIXTURE - SINGLE HEAD EXAMPLE
DATE:
DESIGNED:
DRAWN:
CHECKED:
REVISIONS:
WRITTEN DIMENSIONS ON THESE DRAWINGS
SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS. CONTRACTORS SHALL VERIFY
AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS ON THE JOB
AND THIS OFFICE MUST BE NOTIFIED OF
ANY VARIATION FROM THE DIMENSIONS AND
CONDITIONS SHOWN BY THESE DRAWINGS
_3/
/2
:5 9:
A
M
2025-06-13
BID SET
434-846-1350 Fax: 434-846-1351 904 Lakeside Drive, Lynchburg, VA 24501
423-331
PR
OJ
EC
T
NO
V D
O T
D
IL
LW
Y
N A
R
EA
H
EA
D Q
U A
R
TE
R S
CO
M
BI
NA
TI
ON
B
UI
LD
IN
G
FU
EL
C
EN
TE
R
TH
O
M A
S R
O A
IL
LW
Y N
, V A
PR
OJ
EC
T
CO
DE
:5
-1
-0
NAV/MGB
NAV
MGB
ANTENNA TO BE RELOCATEDA
2E1.02E1.0
ENLARGED MAIN ELECTRICAL POWER RACK OVERHEAD PLANB
2E1.02E1.0
ADDENDUM 1: 2026-03-13
ADDENDUM 2: 2026-03-19
AutoCAD SHX Text
E. CAB.
AutoCAD SHX Text
MIXED HARDWOODS
AutoCAD SHX Text
18" PINE
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
SP
AutoCAD SHX Text
PROPANE TANK
AutoCAD SHX Text
FUEL STATION
AutoCAD SHX Text
COMBO BUILDING
AutoCAD SHX Text
SPREADER BARN CANOPY
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
BLOCK GARAGE
AutoCAD SHX Text
CHEMICAL STORAGE
AutoCAD SHX Text
C.L. FENCE ON VDOT PROPERTY
AutoCAD SHX Text
GATE
AutoCAD SHX Text
ASPHALT CURB
AutoCAD SHX Text
ASPHALT CURB
AutoCAD SHX Text
GATE
AutoCAD SHX Text
GATE
AutoCAD SHX Text
PBE3
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL1
AutoCAD SHX Text
SL2
AutoCAD SHX Text
AutoCAD SHX Text
PBE2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PBE1
AutoCAD SHX Text
PBT1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PBE4
AutoCAD SHX Text
ELECTRICAL POWER RACK
AutoCAD SHX Text
PBE AHQ
AutoCAD SHX Text
PBT AHQ
AutoCAD SHX Text
PANEL "A" (ETR)
AutoCAD SHX Text
(TYP, UON)
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text
FI-2
AutoCAD SHX Text
FI-6
AutoCAD SHX Text
SEE SHEET 2E2.0 FOR POINTS OF WIRING TERMINATION
AutoCAD SHX Text
AutoCAD SHX Text
CT CABINET
AutoCAD SHX Text
METER
AutoCAD SHX Text
GENSET E-STOP
AutoCAD SHX Text
"MCCB-SE"
AutoCAD SHX Text
DISCONNECT "DS-SE"
AutoCAD SHX Text
PANEL "PP1"
AutoCAD SHX Text
PANEL "MDP"
AutoCAD SHX Text
ATS
AutoCAD SHX Text
LOAD BANK REMOTE CONTROL PANEL
AutoCAD SHX Text
"LC" SITE LGT CONTROL
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1"-30'-0"
AutoCAD SHX Text
CONSTRUCTION NOTES
AutoCAD SHX Text
1. SERVICE-ENTRANCE CONDUITS FOR COMBO BUILDING. SEE PANEL "LV" SCHEDULE FOR SIZE, TYPE, AND FILL. SERVICE-ENTRANCE CONDUITS FOR COMBO BUILDING. SEE PANEL "LV" SCHEDULE FOR SIZE, TYPE, AND FILL. 2. (2) - 1" CONDUITS UNDER GROUND TO UTILITY ROOM. TERMINATE (1) AT PANEL "LV" AND (1) AT COMMUNICATION (2) - 1" CONDUITS UNDER GROUND TO UTILITY ROOM. TERMINATE (1) AT PANEL "LV" AND (1) AT COMMUNICATION BACK BOARD FOR FUTURE POWER AND CONTROLS TO GATE FENCE. 3. (3) 5" UGT CONDUITS FROM POLE/PEDESTALS TO COMBO BUILDING (3) 5" UGT CONDUITS FROM POLE/PEDESTALS TO COMBO BUILDING 4. INSTALL EVCS EQUIPMENT FURNINSHED BY OWNER. CHARGING STATION SHALL COMPLY WITH 2010 ADA STANDARDS FOR INSTALL EVCS EQUIPMENT FURNINSHED BY OWNER. CHARGING STATION SHALL COMPLY WITH 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ASAD) INCLUDING, BUT NOT LIMITED TO SECTIONS 305, 308, AND 304. COORDINATE FINAL LOCATION WITH OWNER. SEE SHEET 2E2.2 FOR ADDITIONAL DETAILS. 5. DATA AND POWER PULL BOXES FOR FUEL STATION. PROVIDE CONDUITS PER TMS FUEL DISPENSING RISER DIAGRAM ON DATA AND POWER PULL BOXES FOR FUEL STATION. PROVIDE CONDUITS PER TMS FUEL DISPENSING RISER DIAGRAM ON FUEL STATION DRAWING 3E3 AND DETAIL H ON PROTOTYPE COMBO BUILDING E12. LOCATE NEAREST EDGE 20' MINIMUM FROM NEAREST EDGE OF DISPENSERS. 6. WIREWAYS ON EXTERIOR OF STRUCTURE, SEE COMBO BUILDING PROTOTYPE PLANS. WIREWAYS ON EXTERIOR OF STRUCTURE, SEE COMBO BUILDING PROTOTYPE PLANS. 7. SITE LIGHTING CIRCUIT TO PANEL "PP1" VIA LC SITE LIGHTING CONTROL AT POWER RACK. SEE SCHEDULES ON DRAWING SITE LIGHTING CIRCUIT TO PANEL "PP1" VIA LC SITE LIGHTING CONTROL AT POWER RACK. SEE SCHEDULES ON DRAWING 2E2.2 FOR CONDUCTORS AND CONDUITS SIZE. 8. ALARM HORN/LIGHT, NOTIFICATION ALARM MOUNTED ON COMBO BUILDING. PROVIDE "EMERGENCY FUEL SHUTOFF" SIGN ALARM HORN/LIGHT, NOTIFICATION ALARM MOUNTED ON COMBO BUILDING. PROVIDE "EMERGENCY FUEL SHUTOFF" SIGN MOUNTED TO BUILDING. 9. PROVIDE CONCRETE PAD ALONG FRONT OF EXISTING ELECTRICAL SERVICE RACK SIMILAR TO DETAIL E ON DRAWING 1E5. PROVIDE CONCRETE PAD ALONG FRONT OF EXISTING ELECTRICAL SERVICE RACK SIMILAR TO DETAIL E ON DRAWING 1E5. PAD SHALL BE THE LENGTH OF THE RACK BY THE WIDTH REQUIRED TO PROVIDE 3' OF CLEARANCE IN FRONT OF THE DEEPEST PIECE OF EQUIPMENT ON THE RACK. 10. PROVIDE E-STOP ON A BOLLARD SIMILAR TO BOLLARD DETAIL ON FUEL STATION DRAWING 3AS2. E-STOP SHALL BE A PROVIDE E-STOP ON A BOLLARD SIMILAR TO BOLLARD DETAIL ON FUEL STATION DRAWING 3AS2. E-STOP SHALL BE A MINIMUM OF 20' FROM THE NEAREST FUEL DISPENSER AND A MAXIMUM OF 100' FROM THE FARTHEST FUEL DISPENSER. CONCEAL CONDUIT WITHIN BOLLARD PRIOR TO CONCRETE PLACEMENT. FACE OF E-STOP SHALL BE A MAXIMUM OF 18" FROM THE FACE OF PAVEMENT. TOP OF E-STOP SHALL BE A MAXIMUM OF 44" ABOVE THE TOP OF PAVEMENT. PAINT BOLLARD TO MATCH PLASTIC COVERS ON FUEL STATION BOLLARDS. PROVIDE "EMERGENCY FUEL SHUTOFF" LABEL ON BOLLARD. 11. RELOCATE EXISTING ANTENNA TO BUILDING, SHOWN ON SHEET E4 AND AS DETAILED ON SHEET E8. COORDINATE WITH RELOCATE EXISTING ANTENNA TO BUILDING, SHOWN ON SHEET E4 AND AS DETAILED ON SHEET E8. COORDINATE WITH OWNER FOR CHANGEOVER TIMING. DO NOT REMOVE EXISTING ANTENNA UNTIL NEW SERVICE TO THE ANTENNA IS SET UP AT COMBO BUILDING TO ENSURE THAT DOWNTIME IS MINIMIZED. 12. CONNECT #6 BCSD GEC USED TO BOND PROPANE GAS SERVICE ENTRANCE TO GROUNDING COUNTERPOISE. SEE DETAIL CONNECT #6 BCSD GEC USED TO BOND PROPANE GAS SERVICE ENTRANCE TO GROUNDING COUNTERPOISE. SEE DETAIL ON SHEET M5.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NONE
AutoCAD SHX Text
UNDERGROUND PULL BOX SCHEDULE
AutoCAD SHX Text
PULL BOX ID
AutoCAD SHX Text
DIMENSIONS
AutoCAD SHX Text
CONSTRUCTION RATING
AutoCAD SHX Text
COVER LABEL
AutoCAD SHX Text
PBE1
AutoCAD SHX Text 24" X 36" X 24" D
AutoCAD SHX Text
AASHTO H20
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PBE2
AutoCAD SHX Text 12" X 18" X 24" D
AutoCAD SHX Text
AASHTO H20
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PBE3
AutoCAD SHX Text 12" X 18" X 24" D
AutoCAD SHX Text
AASHTO H20
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PBE4
AutoCAD SHX Text 12" X 18" X 24" D
AutoCAD SHX Text
AASHTO H20
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PBT1
AutoCAD SHX Text 24" X 36" X 24" D
AutoCAD SHX Text
AASHTO H20
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
PBE AHQ
AutoCAD SHX Text
SEE SHEET E11
AutoCAD SHX Text
SEE SHEET E11
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
PBT AHQ
AutoCAD SHX Text
SEE SHEET E11
AutoCAD SHX Text
SEE SHEET E11
AutoCAD SHX Text
TELECOM
AutoCAD SHX Text
NOTE: SEE DETAIL A ON DRAWING 2E2.1
AutoCAD SHX Text
XX
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text 2'
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text AFTER RELOCATION, CONTRACTOR TO DEMOLISH POLE AND ASSOCIATED FOUNDATION, WHERE EXTANT.
AutoCAD SHX Text
ANTENNA TO BE RELOCATED
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text 30'
AutoCAD SHX Text 1" = 30'
AutoCAD SHX Text 0'
AutoCAD SHX Text 30'
AutoCAD SHX Text 60'
| Addendum #2 (3).pdf |
| 423-331 Electrical 2026-03-19.pdf |
| Sheets and Views |
| 1E1.1 423-331-1E1.1 |
| 2E1.0 423-331-2E1.0 |
File details come from the government source that posted it. Updated .