16-33-ITB-26 Pond Improvements for Charles J Herbert Drive Pond 4.22.26.pdf
PDF 12 MB Posted
- Attached to
- Pond Improvements Cadillac Drive & RJ Conlan
- Solicitation number
- 33-ITB-26
- Issued by
- Brevard County, Florida
About this file
This is a construction plans document for pond improvements at Robert J. Conlan Drive in Palm Bay, Florida, prepared by CONSOR North America, Inc. for the City of Palm Bay Public Works Department. The project (Contract 12-0-2024/GB, Project 25SU09) involves comprehensive improvements to an existing pond system, including erosion control measures, site grading, drainage infrastructure, wetland enhancements, and the installation of a submersible pump system with solar panels. The work encompasses the construction of media-enhanced filtered wetlands with 4,345 square feet of shrub plantings and 5,736 square feet of herbaceous plantings at specified spacing intervals. Key infrastructure includes 18-inch and 4-inch drainage pipes, four underground drainage structures with cleanouts, a pump system designed to operate at 14.89 gallons per minute with 10.21 feet of head, and associated control mechanisms. Site access is restricted and requires background checks completed by L3Harris Technologies Inc., the adjacent property owner, with construction personnel requiring approved access badges. The project area includes portions of city-owned Parcel ID 28-37-23-00-796 and a 30-foot drainage easement through L3Harris-owned Parcel ID 28-37-23-50-*-1, which is designated as a Superfund site (EPA ID FLD000602334) under institutional controls per the April 2024 five-year review.
The contractor must comply with all City of Palm Bay standards, FDOT specifications, FDEP NPDES requirements, OSHA trench safety standards, and site-specific Superfund remediation restrictions. Construction requirements include the use of PVC piping (Schedule 40 or SDR 26), 60-mil HDPE or PVC geomembrane liners meeting FDOT APL 531 specifications, bioactivated clay-tire-sand filtration media (Bold & Gold CTS or equivalent), and engineered growth media with specific composition parameters. The contractor is responsible for notifying relevant agencies at least 48 to 72 hours prior to commencing work, including the City Engineer, Sunshine 811 for utility locates, L3Harris security for site access coordination, and the City's Right-of-Way Use Services. All disturbed areas must be stabilized with sod or seed and achieve 80 percent germination prior to final inspection. The contractor must maintain the planted areas for a one-year establishment period and replace any dead or failing plants at their own expense. Coordination with Robert Schatzman at A-OTC is required with a minimum 14-day notice prior to construction commencement, and the contractor must attend progress meetings throughout the project duration.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2025 Microsoft Corporation © 2025 TomTom
CHIPLEY
TALLAHASSEE
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA
DELAND 4
NEW PORT RICHEY
TAMPA
LAKELAND
MELBOURNE -
COCOA
ORLANDO
BARTOWST PETERSBURG
FT PIERCE
FT MYERS
FT LAUDERDALE
MIAMI
NAPLES
KEY WEST
FORT WALTON
BEACH
PENSACOLA
WEST PALM
BEACH
FLORIDA
TURNPIKE
PANAMA
CITY
LAKE
CITY
DAYTONA
BEACH
SARASOTA -
BRADENTON
BEE LINE
EXPRESSWAY
PROJECT LOCATION
4/9/2026 3:05:57 PM c:\pw_work\american-pw-01\d0984264\RJCP_KEYS01.dwgEric Nelson
N
TH
E O
F F
IC
IA
L
R E C
OR
D O
F T
H
IS
S H E E T
IS
T
H E E
LE
C
TR
ON
IC
F
IL
E D
IG
IT
AL
LY
S
IG
N E D A
N D S
E
AL
E D U
N D E R R
U
LE
1G
-2
3.
4‚ F
.A .C
PLANS PREPARED BY:
INDEX OF PLANS
CONSTRUCTION PLANS
FOR
CITY OF PALM BAY
CITY COUNCIL
MAYOR
DEPUTY MAYOR
COUNCIL MEMBER - SEAT 1
COUNCIL MEMBER - SEAT 2
COUNCIL MEMBER - SEAT 3
ROB MEDINA
MIKE JAFFE
KENNY JOHNSON
RICHARD “MIKE” HAMMER
CHANDLER LANGEVIN
COUNTY OF PALM BAY, FLORIDA
PUBLIC WORKS
CITY OF PALM BAY
POND IMPROVEMENTS
FOR ROBERT J. CONLAN DRIVE POND
CONTRACT 12-0-2024/GB
PROJECT 25SU09
CONSOR NORTH AMERICA, INC.
2818 CYPRESS RIDGE BLVD. SUITE 200
WESLEY CHAPEL, FLORIDA 33544
PHONE: (813) 435-2700
NO. DATE DESCRIPTION APPROVED
REVISIONS
PROJECT LOCATION
ROBERT J. CONLAN DRIVE
N
TOWNSHIP 28 S RANGE 37 ESECTION 23
T-28-S
T-29-S T-28-S
T-29-S
R -3
7- E
R -3
8- E
FOR THE STANDARD DETAILS FOR THE CITY OF PALM BAY
VISIT THE FOLLOWING WEB SITE:
HTTPS://WWW.PALMBAYFLORIDA.ORG/GOVERNMNET/
CITY-DEPARTMENTS-A-TO-E/CUSTOMER-SERVICE/ENGINEERING
PERMIT NO.DATE DESCRIPTION STATUS
PERMITS AND APPROVALS
CITY APPROVAL BLOCK
SHEET NUMBER SHEET NUMBER
1 KEY SHEET
2 GENERAL NOTES
3 EROSION CONTROL & DEMOLITION PLAN
4 SITE LAYOUT
5 CROSS SECTIONS
6 WETLAND PLANTING PLAN
7 SITE DETAILS
8 DRAINAGE DETAILS
9 PUMP DETAILS
ALL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD:
ERIC K. NELSON, JR. P.E. NO. 79361
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY:
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
STATE OF
No.
P R O
FESSIONAL EN
GI
NE
E R
ER
IC
K. NELSON JR.
FLORIDA
79361
LICENSE
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_GENN.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
G E N E R A L
N O T E S
24FD09
EKN
12/11/2025
JAM
12/11/2025
GENERAL NOTES (ALL DRAWINGS)
CONTROL, DATUM, AND BENCHMARKS
1. HORIZONTAL CONTROL:
ALL HORIZONTAL LOCATIONS SHOWN ON THESE PLANS ARE BASED ON THE NORTH AMERICAN DATUM OF 1983 (2011 ADJUSTMENT), FLORIDA EAST ZONE, EXPRESSED IN U.S. SURVEY FEET.
2. VERTICAL CONTROL:
ALL VERTICAL ELEVATIONS SHOWN ON THESE PLANS ARE REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD
88), EXPRESSED IN U.S. SURVEY FEET.
3. BENCHMARKS:
CONSTRUCTION SHALL BE CONTROLLED USING THE FOLLOWING ESTABLISHED BENCHMARKS:
· BENCHMARK NO. 1 (GATRAV 1): ELEV. = 18.48 FT (NAVD 88)
· BENCHMARK NO. 2 (GATRAV 2): ELEV. = 18.53 FT (NAVD 88)
· BENCHMARK NO. 3 (GATRAV 4): ELEV. = 18.53 FT (NAVD 88)
BENCHMARKS ARE LOCATED AS SHOWN ON THE SURVEY CONTROL PLAN. THE CONTRACTOR SHALL VERIFY BENCHMARK STABILITY AND FIELD-CHECK ELEVATIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED IMMEDIATELY TO
THE ENGINEER BEFORE PROCEEDING.
4. COORDINATE BASIS:
ALL PLAN COORDINATES ARE BASED ON THE FLORIDA STATE PLANE COORDINATE SYSTEM, EAST ZONE (0901), EXPRESSED IN U.S.
SURVEY FEET.
SITE ACCESS
1. INGRESS AND EGRESS TO CITY-OWNED PARCEL ID 28-37-23-00-796 SHALL BE THROUGH PARCEL ID 28-37-23-50-*-1, OWNED BY
L3HARRIS TECHNOLOGIES INC., WHICH HAS RESTRICTED SITE ACCESS.
2. ALL CONSTRUCTION PERSONNEL SHALL COMPLETE REQUIRED BACKGROUND CHECKS, REQUIRED BY L3HARRIS TECHNOLOGIES INC., TO
OBTAIN SITE ACCESS BADGES.
3. ANY PERSON WITHOUT AN APPROVED ACCESS BADGE SHALL BE ESCORTED AT ALL TIMES BY AUTHORIZED L3HARRIS SECURITY
PERSONNEL.
CONSTRUCTION / SITE PREPARATION
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADES, AND ELEVATIONS IN THE FIELD PRIOR TO CONSTRUCTION AND REPORT ANY
DISCREPANCIES TO THE ENGINEER.
2. CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES, STRUCTURES, AND VEGETATION TO REMAIN.
3. LIMITS OF CLEARING AND GRADING SHALL BE FIELD-STAKED AND APPROVED BY THE ENGINEER PRIOR TO DISTURBANCE.
4. CONTRACTOR SHALL NOTIFY SUNSHINE 811 AT LEAST 48 HOURS BEFORE ANY EXCAVATION.
5. CONTRACTOR SHALL MAINTAIN ACCESS AND DRAINAGE DURING CONSTRUCTION.
6. ALL DISTURBED AREAS NOT OTHERWISE NOTED SHALL BE STABILIZED WITH SOD OR SEED PER CITY OF PALM BAY STANDARDS.
7. CONTRACTOR SHALL BECOME FAMILIAR WITH AND COMPLY WITH ALL PERMITS AND PERMIT CONDITIONS. OBTAIN PERMISSION FROM THE CITY ENGINEER OR ALL PERMITTING AGENCIES IDENTIFIED IN THE SPECIFICATIONS PRIOR TO COMMENCING SITE WORK.
8. CONTRACTOR SHALL CLEAR AND GRUB ALL ON-SITE VEGETATION EXCEPT TREES IDENTIFIED TO REMAIN.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ROADWAYS, CURBS, SIDEWALKS, UTILITIES, OR BENCHMARKS CAUSED BY CONSTRUCTION ACTIVITIES. DAMAGED BENCHMARKS OR PROPERTY CORNERS SHALL BE REPLACED BY A FLORIDA-LICENSED LAND
SURVEYOR.
10. ALL EXCAVATIONS GREATER THAN 5 FEET SHALL COMPLY WITH OSHA TRENCH SAFETY STANDARDS (29 CFR §1926.650 SUBPART P).
EROSION & SEDIMENT CONTROL
1. INSTALL AND MAINTAIN SILT FENCE, TURBIDITY BARRIER, AND INLET PROTECTION AS SHOWN ON THE EROSION CONTROL PLAN.
2. EROSION CONTROL MEASURES SHALL BE INSTALLED PRIOR TO ANY EARTHWORK AND REMAIN IN PLACE UNTIL FULL STABILIZATION
IS ACHIEVED.
3. TURBIDITY BARRIERS SHALL REMAIN IN PLACE UNTIL WATER IS VISIBLY CLEAR AND CONSTRUCTION IS COMPLETE.
4. ANY SEDIMENT ESCAPING PROJECT LIMITS SHALL BE REMOVED IMMEDIATELY.
5. CONTRACTOR SHALL COMPLY WITH FDEP NPDES REQUIREMENTS AND CITY OF PALM BAY EROSION CONTROL STANDARDS.
MATERIALS & CONSTRUCTION REQUIREMENTS
1. ALL WORK SHALL CONFORM TO CITY OF PALM BAY STANDARDS AND FDOT STANDARD SPECIFICATIONS (LATEST EDITION) UNLESS
OTHERWISE NOTED.
2. PIPE MATERIALS: PVC SCH 40 OR SDR 26 PER ASTM D1785 / D2241, AS INDICATED.
3. UNDERDRAINS: INCLUDE CLEANOUTS PER PLAN AND WRAP IN FILTER FABRIC.
4. IMPERMEABLE LINER: 60 MIL HDPE OR PVC GEOMEMBRANE MEETING FDOT APL 531 REQUIREMENTS.
5. BIOACTIVATED MEDIA (BAM) AND GROWTH SOIL SHALL BE INSTALLED PER PLAN DETAILS.
6. CONTRACTOR SHALL PROVIDE AS-BUILT ELEVATIONS FOR ALL STRUCTURES, INVERTS, AND LINER TIE-INS.
7. PROVIDE CONSISTENT, POSITIVE SLOPE BETWEEN ALL SPOT ELEVATIONS SHOWN ON PLANS.
8. ALL SLOPES 4H:1V OR STEEPER SHALL BE SODDED. SLOPES STEEPER THAN 3H:1V SHALL BE SODDED AND STAKED.
TESTING / INSPECTION
1. THE CITY'S ENGINEER SHALL INSPECT LINER INSTALLATION PRIOR TO SOIL PLACEMENT.
2. COMPACTION TESTING SHALL BE PERFORMED FOR ALL EMBANKMENTS AND BACKFILLS AS REQUIRED BY CITY STANDARDS.
3. PRESSURE TESTS SHALL BE CONDUCTED ON ALL PUMP AND PIPING ASSEMBLIES PRIOR TO OPERATION.
4. NOTIFY THE ENGINEER PRIOR TO MAJOR DEVIATIONS FROM APPROVED PLANS, PIPE BACKFILL, BASE MATERIAL PLACEMENT, AND
ASPHALT PAVING.
5. THE ENGINEER AND CITY WILL REVIEW AND APPROVE SHOP DRAWINGS AND TEST RESULTS; COPIES SHALL BE PROVIDED TO THE
PUBLIC WORKS DEPARTMENT.
SAFETY & ENVIRONMENTAL PROTECTION
1. MAINTAIN ALL WORK IN ACCORDANCE WITH OSHA AND LOCAL SAFETY REQUIREMENTS.
2. PROTECT EXISTING WETLANDS, WATER BODIES, AND VEGETATION OUTSIDE THE WORK AREA FROM DISTURBANCE.
3. STORE ALL FUEL, OIL, AND CHEMICALS AT LEAST 50 FT FROM WETLANDS OR WATER BODIES.
4. SHORING IS REQUIRED WHEN EXCAVATIONS ARE WITHIN 5 FT OF PAVEMENT OR SIDEWALK. ANY UNDERMINING OR DAMAGE SHALL
BE RESTORED TO EQUAL OR BETTER CONDITION AND MEET ADA STANDARDS.
CITY OF PALM BAY GENERAL NOTES
1. ALL DISTURBED AREAS SHALL HAVE GRASS/VEGETATION ESTABLISHED (80% GERMINATION) PRIOR TO FINAL INSPECTION.
2. NOTIFY THE PUBLIC WORKS DEPARTMENT BY EMAIL AT PWDEVELOPMENTREVIEWTEAM@PALMBAYFL.GOV AT LEAST 72 HOURS PRIOR
TO STARTING CONSTRUCTION TO SCHEDULE A PRE-SITE MEETING.
3. SIGNAGE IN THE RIGHT-OF-WAY OR PERMITTED DRIVEWAY REMOVED SHALL BE REPLACED IN ACCORDANCE WITH CITY AND MUTCD
SPECIFICATIONS.
4. CONTRACTOR SHALL NOTIFY RIGHT-OF-WAY USE SERVICES 72 HOURS PRIOR TO ANY OFF-SITE CONSTRUCTION ACTIVITIES, INCLUDING EXCAVATION. SUBMIT ALL TEST RESULTS FROM PUBLIC RIGHT-OF-WAY WORK.
O CONTACT: PUBLIC WORKS DEPARTMENT - RIGHT-OF-WAY USE SERVICES
PHONE: (321) 952-3403 | FAX: (321) 768-6401 | EMAIL: PWPERMITTING@PALMBAYFL.GOV
MAIL: 1050 MALABAR ROAD SW, PALM BAY, FL 32907
5. NOTIFY RIGHT-OF-WAY USE SERVICES AT (321) 953-8965 AT LEAST 48 HOURS PRIOR TO ANY CONSTRUCTION WITHIN A RIGHT-OF-WAY (PAVING, PIPE, GRADING, SIDEWALK). WORK SHALL BE PERFORMED IN THE PRESENCE OF A CITY INSPECTOR.
6. NOTIFY THE LAND DEVELOPMENT DIVISION 48 HOURS PRIOR TO ANY CONSTRUCTION ACTIVITY AND PROVIDE ALL CONCRETE, COMPACTION, AND ASPHALT TESTING RESULTS.
7. ALL UTILITY DESIGN, CONSTRUCTION, MATERIALS, AND TESTING SHALL CONFORM TO THE PALM BAY UTILITIES DEPARTMENT
POLICIES, PROCEDURES, AND STANDARDS HANDBOOK.
8. NOTIFY THE PALM BAY UTILITIES INSPECTOR AT LEAST 48 HOURS PRIOR TO ANY UTILITIES WORK OR ACTIVITY NEAR EXISTING WATER/SEWER LINES. THE CONTRACTOR SHALL NOT OPERATE PUBLIC VALVES WITHOUT AUTHORIZATION.
9. COMPLETE AND SUBMIT ROAD CLOSURE NOTIFICATION FORM 6.02-2 TO THE PUBLIC WORKS DEPARTMENT AT LEAST 72 HOURS
BEFORE ANY ROAD CLOSURE. PROVIDE AN MOT PLAN SEVEN DAYS IN ADVANCE.
10. PRIOR TO HAVING COMBUSTIBLE MATERIAL ON-SITE, ENSURE FIRE HYDRANTS AND PROTECTION SYSTEMS ARE INSTALLED AND
OPERATIONAL.
11. DEWATERING PLANS SHALL BE SUBMITTED BY THE ENGINEER OF RECORD AND APPROVED BY THE CITY PRIOR TO IMPLEMENTATION.
SUPERFUND SITE NOTES:
1. PARCEL ID 28-37-23-50-*-1 (OWNER: L3HARRIS TECHNOLOGIES INC.) IS A DESIGNATED SUPERFUND SITE (EPA ID
FLD000602334). THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE EPA SUPERFUND REQUIREMENTS AND SITE-SPECIFIC RESTRICTIONS. PER EPA FIVE-YEAR REVIEW (APRIL 2024), THE SITE REMEDY IS FUNCTIONING AS
INTENDED; INSTITUTIONAL CONTROLS REMAIN IN EFFECT.
2. NO EXCAVATION IS PROPOSED WITHIN THIS PARCEL UNDER THIS PROJECT.
3. ANY SOIL INCIDENTALLY DISTURBED SHALL REMAIN WITHIN THE SAME PARCEL AND SHALL NOT BE REMOVED FROM THE
SITE, STOCKPILED OFF-SITE, OR DISPOSED OF OFF-SITE.
4. NO ACTIVITIES SHALL OCCUR OUTSIDE OF THE DESIGNATED INGRESS/EGRESS AREA SHOWN ON SHEET 3 (EROSION CONTROL & DEMOLITION PLAN) SHALL OCCUR ON THIS SITE. PROHIBITED ACTIVITIES INCLUDE, BUT ARE NOT LIMITED TO, MATERIAL STOCKPILING, VEHICLE OR EQUIPMENT PARKING, AND VEHICLE OR EQUIPMENT OPERATION.
5. THE CONTRACTOR SHALL NOTIFY ROBERT SCHATZMAN WITH A-OTC A MINIMUM OF FOURTEEN (14) DAYS PRIOR TO COMMENCEMENT OF CONSTRUCTION AND SHALL CONTINUE COORDINATION THROUGHOUT CONSTRUCTION, INCLUDING
ATTENDANCE AT PROGRESS MEETINGS.
ROBERT SCHATZMAN
A-OTC
PO BOX 236727, COCOA, FL 32923
OFFICE: (321) 445-9845 EXT. 409
FAX: (321) 989-0322
CELL: (321) 652-7401
EMAIL: RSCHATZMAN@A-OTC.COM
CITY APPROVAL BLOCK
SITE BENCHMARK GATRAV1
SET 5/8" IRON ROD & CAP
"ECHO UES TP LB 8184"
ELEV = 18.48
SITE BENCHMARK GATRAV2
SET 5/8" IRON ROD & CAP
"ECHO UES TP LB 8184"
ELEV = 18.53
SITE BENCHMARK GATRAV4
SET 5/8" IRON ROD & CAP
"ECHO UES TP LB 8184"
ELEV = 18.53
WATER
WATER
WATER
12" 14"
14" 14" 14"
WATER
WATER
WATER
14" 10" 10"
8"
(3) 10"8"
8"
10"
10" 10"
14" 14"
8"
9"
8"
RIP-RAP
RIP
-RA
PRI
P-
RA
P
TO
P
OF
B
AN
K
TO
E
TO
P
OF
B
AN
K
TO
E
TOE
TOP OF BANK
8" PVC CAP
B-4
N INV. = 8.93' (60" CMP)
N INV. = 8.90' (60" CMP)
N INV. = 8.81' (60" CMP)
SE INV. = 11.84'
24" CMP
DIRECTION ONLY
BLOWOFF VALVE
ROBERT J. CONLAN DRIVE
ROBERT J. CONLAN DRIVE
TOP OF BANK
TOP OF BANK
TOP OF BANK
TOP
OF B
ANK
TOE
TOP OF BANK
TOE
POST W/
12" WOOD
BIRD NEST
12" PVC
E INV. = 11.10'
W INV. = 10.56'
NO ID NO ID
NO ID
RIP-RAP
RIP-RAP
CONC SLAB
CONC SLAB W/
BACK FLOW PREVENTER
CONC SLAB
TOP OF BANK
TO
P
OF
B
AN
K
TO
E
TOE
TO
P O
F B
AN
K
TO
E
TOE
TOP OF BANK
TOE
TOP OF BANK
TOE
TOP OF BANK
TOE
TO
P O
F B
AN
K
RIP-RAP
BLOWOFF
VALVE
PARCEL ID: 28-37-23-00-796
CITY OF PALM BAY
ORB 7468, PAGE 46 (EXHIBIT "A")
PARCEL ID: 28-37-23-00-789
L3HARRIS TECHNOLOGIES INC
ORB 7468, PAGE 46 (EXHIBIT "B")
"LESS THE WEST 30.0 FEET FOR DRAINAGE"
ORB 7468, PAGE 46 (EXHIBIT "A")
"LESS THE WEST 30.0 FEET FOR DRAINAGE"
ORB 7468, PAGE 46 (EXHIBIT "B")
60' R/W KNOWN AS VALENCIA DRIVE
AS SHOWN ON PLAT BOOK 73, PAGE 76
30' R/W
PLAT BOOK 13, PAGE 103
30'
60'
30'
PARCEL ID: 28-37-23-00-761.1
PENIEL SDA CHURCH OF PALM BAY CORP.
ORB 10295, PAGE 1456
APPARENT/APPROXIMATE RIGHT OF WAY LINE
APPARENT/APPROXIMATE RIGHT OF WAY LINE
AP
P
AR
E N T/
AP
P R
OX
IM
AT
E P
R
OP
E R
TY
L
IN
E
AP
P
AR
E N T/
AP
P R
OX
IM
AT
E P
R
OP
E R
TY
L
IN
E
WOODLINE
WOODLINE
8 9
5 4
APPROXIMATE LOCATION OF
12" PVC WM
TH
TH1-1
TH
TH1-4
NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)
EXIST. CONC. SLAB
(TO REMAIN - SEE NOTE 1)
EXIST. CONC. SLABS AND BACK FLOW PREVENTERS
(TO REMAIN - SEE NOTE 1)
EXIST. CONC. SLABS & VALVE
(TO REMAIN - SEE NOTE 1)
EXIST. BLOWOFF VALVE
(TO BE REMOVED)
BEGIN SILT FENCE
N: 1343280.8' E: 785950.5
N: 1343287.3' E: 785985.7
N: 1343265.3' E: 786072.3
BEGIN DOUBLE SILT FENCE
N: 1343171.3' E: 786074.5
N: 1343162.8' E: 786111.7
N: 1343174.6' E: 786134.5
N: 1343198.0' E: 786159.0
N: 1343210.7' E: 786165.3
N: 1343408.0' E: 786168.4
END DOUBLE SILT FENCE
N: 1343459.8' E: 786107.6N: 1343421.8'
E: 786079.3
N: 1343329.8' E: 786072.6
N: 1343318.3' E: 786022.0
END SILT FENCE
N: 1343323.8' E: 786003.6
BEGIN TURBIDITY BARRIER
N: 1343423.6' E: 786160.0
N: 1343438.5' E: 786171.2
N: 1343450.7' E: 786156.7
END TURBIDITY BARRIER
N: 1343441.3' E: 786140.6
BEGIN TURBIDITY BARRIER
N: 1343141.3' E: 786166.3
END TURBIDITY BARRIER
N: 1343176.0' E: 786155.9
822 LF OF SILT FENCE
330 LF OF SILT FENCE
38 LF OF SILT FENCE
56 LF OF FLOATING TURBITY BARRIER
44 LF OF FLOATING TURBITY BARRIER
SOIL TRACKING PREVENTION DEVICE
PER FDEP EROSION CONTROL MANUAL
(SEE DETAIL (SHEET 7)
EXIST 12" PVC WM
(TO REMAIN - SEE NOTE 1)
N: 1343288.1' E: 786040.3
N: 1343318.5' E: 786051.1
EXIST TREE TO BE REMOVED (TYP)
EXIST. RECLAIM RPZ ASSEMBLY
(TO BE ADJUSTED TO GRADE)
30' DRAINAGE EASEMENT
30' RIGHT OF WAY
PARCEL ID: 28-37-23-50-*-1
OWNER: L3HARRIS TECHNOLOGIES INC
(SEE SHEET 2 - GENERAL NOTES
REGARDING THE SUPERFUND SITE)
PARCEL ID: 28-37-23-00-796
OWNER: CITY OF PALM BAY
NPW TO REMAIN
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_DEMO-ECP.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
E R O S I O N C
O N T R O L
D E M
O L I T I O N P
L A N
24FD09
EKN
12/11/2025
JAM
12/11/2025
CITY APPROVAL BLOCK
Feet 0 20 40
NOTES:
1. EXISTING ITEMS SHOWN TO REMAIN SHALL BE PROTECTED
IN PLACE BY THE CONTRACTOR. ANY DAMAGE SHALL BE
REPAIRED OR REPLACED AT NO COST TO THE CITY.
2. ALL SALVAGEABLE AND REUSABLE MATERIALS SHALL BE
REMOVED AND DELIVERED TO THE PUBLIC WORKS
COMPOUND PER INSPECTIONS’ DETERMINATION.
STRUCTURE TABLE
STRUCTURE
NO.
S-1
S-2
S-5
S-6
NORTHING/
EASTING
N: 1,343,161.85' E: 786,132.94'
N: 1,343,197.10' E: 786,106.34'
N: 1,343,231.78' E: 786,181.22'
N: 1,343,232.15' E: 786,146.11'
STRUCTURE DETAILS
18" MES (1:2)
FDOT INDEX 430-021
TOP = 9.21
P-1 INV OUT = 7.50 (NW)
TYPE H 4-GRATE DBI (MODFIED)
INDEX 425-052
TOP = 18.25
P-1 INV IN = 8.00 (SE)
18" MES (1:2)
FDOT INDEX 430-021
TOP = 13.71
P-2 INV IN = 12.00 (W)
DBI TYPE D
FDOT INDEX 425-052
TOP = 17.75
P-2 INV OUT = 12.50 (E)
PIPE TABLE
PIPE
NO.
P-1
P-2
UDP-1
UDP-2
UDP-3
UDP-4
DESCRIPTION
18" PIPE
18" PIPE
4" PVC
4" PVC
4" UNDERDRAIN
4" UNDERDRAIN
LENGTH
44'
35'
9'
58'
29'
30'
SLOPE
1.13%
1.42%
1.16%
0.17%
0.35%
0.34%
INVERTS
7.50' (S-1) 8.00' (S-2)
12.50' (S-6) 12.00' (S-5)
12.40' (UD-2)
12.30' (UD-1)
12.50' (UD-3)
12.40' (UD-2)
14.40' (UD-4)
14.30' (UD-3)
14.40' (UD-5)
14.30' (UD-3)
STRUCTURE TABLE
STRUCTURE
NO.
UD-1
UD-2
UD-3
UD-4
NORTHING/
EASTING
N: 1,343,146.55' E: 786,082.17'
N: 1,343,154.90' E: 786,080.19'
N: 1,343,200.13' E: 786,116.92'
N: 1,343,213.87' E: 786,143.44'
STRUCTURE DETAILS
4" MES
TOP = 12.66
UDP-1 INV IN = 12.30 (N)
4" CLEANOUT
TOP = 17.71
UDP-2 INV IN = 12.40 (NE)
UDP-1 INV OUT = 12.40 (S)
DBI TYPE D
FDOT INDEX 425-052
TOP = 18.25
UDP-3 INV IN = 14.30 (NE)
UDP-4 INV IN = 14.30 (NE)
UDP-2 INV OUT = 12.50 (SW)
4" CLEANOUT
TOP = 17.51
UDP-3 INV OUT = 14.40 (SW)
STRUCTURE TABLE
STRUCTURE
NO.
UD-5
NORTHING/
EASTING
N: 1,343,216.20' E: 786,143.51'
STRUCTURE DETAILS
4" CLEANOUT
TOP = 17.52
UDP-4 INV OUT = 14.40 (SW)
S 60° 31' 26" W 33.42
S ° 0
0' 0" E
.3
-2 .0 0%
1:
N: 1343192.7 E: 786078.6
EL 18.74
N: 1343192.6 E: 786090.6
EL 18.50
N: 1343421.1 E: 786081.3
EL 18.74
N: 1343420.9 E: 786093.3
EL 18.50
N: 1343340.6 E: 786080.4
EL 18.74
N: 1343306.0 E: 786044.9
EL 18.39
N: 1343306.4 E: 786014.4
EL 18.20
N: 1343282.6 E: 785948.1
EL 18.70
N: 1343334.9 E: 786002.3
EL 19.00
N: 1343291.9 E: 785978.6
EL 18.49
N 89° 16' 23" W 66.25
R 50.0'
R 15.0'
S 89° 16' 23" E 30.49
N 00° 40' 30" E 80.43
N 89° 19' 30" W 12.00
R 35.0' 1:
4 1:4
1:6
APPROXIMATE GRADING TIE-DOWN
N: 1343197.1' E: 786104.8'
EL 18.5'
N: 1343399.3' E: 786152.4'
EL 18.5'
N: 1343188.3' E: 786119.8'
EL 18.5'
N: 1343415.8' E: 786107.3'
EL 18.5'
N: 1343213.3' E: 786153.9'
EL 18.5'
N: 1343391.6' E: 786156.0'
EL 18.5'
N: 1343423.3' E: 786123.8'
EL 18.5'
N: 1343204.7' E: 786148.8'
EL 18.5'
R 10.0'
R 10.0'
R 10.0'
RIPRAP RUBBLE
5'X5'
N: 1343255.6 E: 786079.4
EL 18.74
N: 1343291.0 E: 786044.8
EL 18.20
EL 17.5'
EL 18.0'
1:6 1:50
1:4
SOLAR PANEL MOUNT
N: 1343193.2 E: 786094.0
R 35.0'
R 10.0'
N 00° 40' 30" E 62.93
WATER
WATER
WATER
12" 14"
14" 14" 14"
WATER
WATER
WATER
14" 10" 10"
8"
(3) 10"8"
8"
10"
10" 10"
14" 14"
8"
9"
8"
8 9
5 4
TH
TH1-1
TH
TH1-4
NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)
WATER
WATER
WATER
12" 14"
14" 14" 14"
WATER
WATER
WATER
14" 10" 10"
8"
(3) 10"8"
8"
10"
10" 10"
14" 14"
8"
9"
8"
8 9
5 4
TH
TH1-1
TH
TH1-4
NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)
A
A
B B
S-2
S-6
UD-3
S-1
C C
UD-1
UD-4
UD-5
S-5
UD-2
1-1/4" PVC ELBOW 45°
1-1/4" TO 2" PVC REDUCER
3' OF 2" PVC
P-1
P-2
UDP-4
UDP-3
UDP-2
UDP-1
2" PIPE OUTLET
W/ CONCRETE COLLAR
(SEE SHEET 8 FOR DETAIL)
MEDIA ENHANCED FILTERED WETLAND
SEE SHEET 5 - CROSS SECTIONS AND
SHEET 6 - WETLAND PLANTING PLAN FOR
ADDITIONAL DETAIL
GRADED
ACCESS
DRIVE
PARCEL ID: 28-37-23-00-796
OWNER: CITY OF PALM BAY
30' DRAINAGE EASEMENT
30' RIGHT OF WAY
PARCEL ID: 28-37-23-50-*-1
OWNER: L3HARRIS TECHNOLOGIES INC
(SEE SHEET 2 - GENERAL NOTES
REGARDING THE SUPERFUND SITE)
GRAVEL (12" DEEP)
GRAVEL (12" DEEP)
215' OF 1-1/4" PVC
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\PDPL_RJCP.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
S I T E L
A Y O U T
24FD09
EKN
12/11/2025
JAM
12/11/2025
Feet 0 20 40
SECTION A-A
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
SECTION B-B
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
SECTION C-C
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
1:
1:4
15'
S-1 TO S-2
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
1+00 2+00
S-5 TO S-6
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
UD-1 TO UD-5
HORIZONAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 4'
1+00
S-1
S-2
S-5
S-6
UD-1
UD-2
UD-4
FL 7.93'
FL 12.12'
FL 12.40'
FL 12.40' FL 12.50'
FL 14.30'
FL 14.40'
FL 7.50' FL 8.00'
FL 12.50'
FL 12.00'
UDP-2
FL 12.48'
1-1/4" PVC ELBOW 45°
1-1/4" TO 2" PVC REDUCER
EL 18.50'
EL 18.40'
EL 18.40'
EL 18.50'
EL 17.50'
EL 18.00'
Existing Grade
EL 16.00'
EL 14.00'
EL 16.50'
EL 17.00'
1:6
1:6
2.00% 2.00%
EL 18.50' 2.00%
EL 18.40'
18" DEEP GROWTH MEDIA
1:4
EL 18.50'
SOD
SOD
SOD
60 mil HDPE IMPERMEABLE LINERNON-WOVEN FILTER FABRIC
(ENCAPSULATE FILTER MEDIA)
18" PIPE"
4" PVC"4" PVC"
18" PIPE"
UD-3
EL 15.00'
EL 17.00'
UD-5
FL 14.40'
4" UNDERDRAIN
18" DEEP GROWTH MEDIA
NON-WOVEN FILTER FABRIC
GRAVEL SPEADER TRENCH
RIPRAP
GRADED ACCESS DRIVE
SHWT El.
10.60
10YR/24HR DHW
13.94
25YR/24HR DHW
14.58
100YR/24HR DHW
15.77
25YR/24HR DHW 17.87
100YR/24HR DHW 17.93
BAM
60 mil HDPE IMPERMEABLE LINER
Existing Grade
PROPOSED GRADE
Existing Grade
PROPOSED GRADE
Existing Grade
PROPOSED GRADE
EXIST. NPW
FL 14.29'
1:6 1:6
PROPOSED GRADE
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\PDPL_RJCP.dwg Apr 09, 2026 - 3:20pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M
E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
C R O S S
S E C T I O N S
24FD09
EKN
12/11/2025
JAM
12/11/2025
FILL MATERIAL SPECIFICATIONS
1. GROWTH MEDIA
· GROWTH MEDIA SHALL MEET THE FOLLOWING MINIMUM CRITERIA:
· SAND FRACTION: 60-70% (BY VOLUME)
· FINES (SILT/CLAY): 20-30%
· ORGANIC MATTER: 5-10%
· PH: 6.0-7.5
· HYDRAULIC CONDUCTIVITY: ≥ 1 × 10⁻³ CM/S
· MEDIA SHALL BE FREE OF DEBRIS, ROCKS > 2 IN, AND CONTAMINANTS.
· MEDIA SHALL BE GRADED TO MAINTAIN DESIGNED WATER FLOW PATHS AND
WETLAND DEPTH.
2. BIOSORPTION ACTIVATED MEDIA (BAM) SHALL BE BOLD & GOLD® CTS
(CLAY-TIRE-SAND) FILTRATION MEDIA OR EQUIVELENT. BOLD & GOLD® CTS
FILTRATION MEDIA IS DEVELOPED BY THE UNIVERSITY OF CENTRAL FLORIDA'S
STORMWATER MANAGEMENT ACADEMY, MANUFACTURED BY ECS, DISTRIBUTED BY
FERGUSON WATERWORKS.
3. GRADED ACCESS DRIVE
· FDOT INDEX 330-001 (PAVED & GRADED DRIVEWAYS)
· FDOT SPECIFICATIONS SECTIONS 120 & 286 (FILL & DRIVEWAY BASE)
4. NON-WOVEN FILTER FABRIC SHALL MEET FDOT SPECIFICATIONS 514 & 985 FOR
TYPE D-5 SEPARATION GEOTEXTILE
WATER
TH
TH1-1
TH
TH1-4
NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)
WATER
TH
TH1-1
TH
TH1-4
NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)NPW(B)
VARIOUS SHRUBS AT 6' SPACING
4,345 SF
SEE TABLE ABOVE
VARIOUS HERBACEOUS PLANTS AT 3' SPACING
5,736 SF
SEE TABLE ABOVE
GRAVEL (12" DEEP)
125 SF
GRAVEL (12" DEEP)
464 SF
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_PLANLD.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T
J C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
W E T L A N D
P L A N T I N G P
L A N
24FD09
EKN
12/11/2025
JAM
12/11/2025
SYMBOL COMMON NAME SCIENTIFIC NAME SIZE SPACING QUANTITY
SOFT RUSH JUNCUS EFFUSUS BARE ROOT 3' OC 170
PICKERELWEED
PONTEDERIA
CORDATA BARE ROOT 3' OC 170
GOLDEN CANNA CANNA FLACCIDA BARE ROOT 3' OC 170
SCARLET HIBISCUS HIBISCUS COCCINEUSBARE ROOT 3' OC 170
BUTTONBUSH
CEPHALANTHUS
OCCIDENTALIS 1 GALLON 6' OC 41
SALTMARSH
MALLOW
KOSTELETZKYA
PENTACARPOS 1 GALLON 6' OC 41
SALTBUSH
BACCHARIS
HALIMIFOLIA 1 GALLON 6' OC 41
Feet 0 20 40
LANDSCAPE NOTES
1. PLANT MATERIAL
· ALL PLANT MATERIALS SHALL BE FLORIDA NO. 1 GRADE, NURSERY-GROWN PER FDACS STANDARDS.
· ONLY SHRUBS AND BARE-ROOT HERBACEOUS PLANTS SHALL BE INSTALLED; NO TREES ARE SPECIFIED.
· SPECIES AND QUANTITIES ARE AS SHOWN ON THE APPROVED LANDSCAPE PLAN.
2.PLANTING ZONES
· PLANT SPECIES ARE GROUPED BY SHRUB AND HERBACEOUS ZONES.
· CONTRACTOR SHALL RANDOMLY DISTRIBUTE SPECIES WITHIN EACH ZONE, MAINTAINING EVEN COVERAGE
AND NO CLUMPING.
· SPACING SHALL FOLLOW THE PLANTING TABLE PROVIDED ON THE LANDSCAPE PLAN.
3.PLANTING MEDIA (GROWTH MEDIA)
· ALL PLANTS SHALL BE INSTALLED IN THE ENGINEERED GROWTH MEDIA SPECIFIED FOR THE ENHANCED
WETLAND.
4.PLANTING
· BARE-ROOT HERBACEOUS PLANTS: SOAK ROOTS PRIOR TO PLANTING, SPREAD EVENLY IN PREPARED HOLES.
· SHRUBS (CONTAINER OR BALLED-AND-BURLAPPED): REMOVE CONTAINERS, LOOSEN ROOTS, AND PLANT SO
THAT THE TOP OF THE ROOT BALL IS FLUSH WITH MEDIA SURFACE.
· ALL PLANTS SHALL BE INSTALLED PLUMB AND FIRMED IN MEDIA, AVOIDING AIR POCKETS.
5.MULCHING
· APPLY 2-3 INCHES OF SHREDDED HARDWOOD OR PINE BARK MULCH AROUND ALL PLANTS.
· KEEP MULCH 1-2 INCHES AWAY FROM PLANT CROWNS.
7.MAINTENANCE
· CONTRACTOR SHALL MAINTAIN THE PLANTED AREAS FOR A 1-YEAR ESTABLISHMENT PERIOD, INCLUDING:
§ REMOVAL OF DEAD, DAMAGED, OR DISEASED PLANTS.
§ WEED CONTROL TO PREVENT COMPETITION.
§ MULCH REPLENISHMENT AS NEEDED.
· DEAD OR FAILING PLANTS SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
8.EROSION AND PROTECTION
· PROTECT ALL PLANTING AREAS DURING CONSTRUCTION FROM SEDIMENT DEPOSITION AND CONSTRUCTION
DAMAGE.
· AVOID PEDESTRIAN OR VEHICLE TRAFFIC IN PLANTED ZONES UNTIL VEGETATION IS ESTABLISHED.
9.COORDINATION
· PLANTING SHALL OCCUR AFTER FINAL GRADING AND MEDIA PLACEMENT ARE COMPLETE.
· CONTRACTOR SHALL COORDINATE WITH THE ENGINEER TO VERIFY MEDIA DEPTH, GRADE, AND WATER FLOW
PATHS PRIOR TO PLANTING.
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_DRDT.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
S I T E D
E T A I L S
24FD09
EKN
12/11/2025
JAM
12/11/2025
SUMP 6.00'
WEIR/PIPE FL 8.00'
SKIMMER BOTTOM 7.50'
6" WIDE CONC.
WEIR WALL
6" WIDE CONC.
WEIR WALL
SKIMMER
SKIMMERSKIMMER TOP 13.10'
3.25' 0.5'
1' 1' 0.5' 2.5'
TOP 18.50'
FL 8.00'
18" PIPE
TO S-1
18" PIPE
TO S-1
TYPE H (MODIFIED)
FDOT INDEX 425-052
S-2
8.75'
3.
1'
4" PVC PERFORATED
WELL PIPE*
SUBMERSABLE WELL PUMP*
PIPE STRAP (TYP)**
WELL SEAL
OUTLET "T"
CUT OR MANUFACTURE GRATE
OPENINGS FOR 4" RISERS**
* TWO (2) WELL PUMP ASSEMBLIES, ASSOCIATED WELL PIPING,
ELECTRICAL CONTROLS AND SOLAR PANELS SHALL BE
INSTALLED PER THE MANUFACTURER’S RECOMMENDATIONS.
** A MINIMUM OF THREE (3) PIPE STRAPS SHALL BE INSTALLED,
WITH WALL/PIPE SPACERS AS NECESSARY TO ACCOMMODATE
THE GRATE OPENING.
1-1/4" PVC PIPE TO OUTLET
EL 17.0
4" THICK CONCRETE PAD
24"x48"x4" CONCRETE PAD
1-1/4" PVC CHECK VALVE
ELECTRICAL WIRING*
MOUNTING POST
CONTROL BOXES*
1-1/4" 90° BEND
1-1/4" PVC PIPE TO OUTLET
1-1/4" PVC CHECK VALVE
1-1/4" PVC CHECK VALVE
1-1/4" 45° BEND
1-1/4" PVC WYE
PLUMBING DETAIL
SEE PLUMBING DETAIL RIGHT
1-1/4" PVC WYE
CONTROL BOXES*
MOUNTING POST
TYPE D
FDOT INDEX 425-052
UD-3
CAP
W/ 2.0-IN HOLE
4" TEE
REMOVABLE PLUG
FL 14.25
4" PVC TO UD-2
(2) 4" UD FROM UD-4/UD-5
FL 14.3
SUMP EL 13.0
TOP EL 18.25
EL 17.5
SOLAR PANELS*
TRANSDUCER (PRESSURE
LEVEL) MONITOR
DROP PIPE*
ELECTRICAL WIRING CONDUIT
TRANSDUCER (PRESSURE
LEVEL) MONITOR
TRANSDUCER MONITOR WIRE IN
CONDUIT FROM CONTROL BOX
12" MIN
24"
6"
NON-WOVEN FILTER FABRIC
24"24"
2" PVC
3" THICK INLET PAVEMENT
24"
3" THICK INLET PAVEMENT
GRAVEL
TOP VIEW
SECTION A-A
PVC OUTLET COLLAR
NTS
A A
0" TO 1"
DO NOT CUT PIPE FLUSH WITH
CONCRETE. EXTEND PIPE 2"–4"
BEYOND CONCRETE FACE.
GRAVEL
TRANSDUCER MONITOR WIRE IN
CONDUIT FROM CONTROL BOX TO UD-3
12" DEPTH
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_DRDT.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
D R A I N A G E
D E T A I L S
24FD09
EKN
12/11/2025
JAM
12/11/2025
1:6
Inputs Calculations Pump Curve Data
Description Value Notes Description Value Notes Q (m3/h) Q (gpm) Q (cfs) Pump Head
(m) Pump Head (ft)
Pump Flow (GPM) 14.89 Design flow for 6 hr/day Flow (ft³/s) 0.033 GPM → ft³/s - - - 178.50
Pond Control Elevation 8.60 Average operating level Discharge Pipe ID (ft) 0.104 Inches → ft 0.25 1.10 0.00 174.60
Wetland Elevation 18.00 Pipe/manifold invert Velocity in Discharge Pipe (ft/s) 3.893 Average velocity 0.50 2.20 0.00 169.70
Suction Elevation (ft) 6.00 Pump inlet Friction Loss Discharge (ft) 0.821 Hazen-Williams 0.75 3.30 0.01 162.40
Suction Pipe Length (ft) - Submersable Pump Friction Loss Suction (ft) 0.000 Hazen-Williams 1.00 4.40 0.01 154.30
Discharge Pipe Length (ft) 10.00 Straight run Total Friction Loss (ft) 0.821 1.25 5.50 0.01 145.40
Pipe Diameter (in) 1.25 Nominal diameter Static Head (ft) 9.400 Discharge − suction 1.50 6.60 0.01 135.70
Hazen-Williams C 140.00 PVC pipe Total Dynamic Head (TDH, ft) 10.22 TDH 1.75 7.71 0.02 124.90
Pump Efficiency 0.50 Pump Brake Power (HP) 0.077 HP = GPMTDH/(3960η_pump) 2.00 8.81 0.02 113.20
Motor Efficiency 0.75 Motor Input Power (HP) 0.102 Include pump efficiency 2.25 9.91 0.02 101.00
Motor Service Factor 1.15 Motor Power (kW) 0.076 HP → kW 2.50 11.01 0.02 87.50
Discharge Fittings (ft equiv) 24.00 Convert elbows, tees, valves Daily Energy (kWh) 0.459 Pump run hours 2.75 12.11 0.03 73.70
Suction Fittings (ft equiv) - Operating Cost ($/day) 2.752 Electricity rate 3.00 13.21 0.03 57.70
Fluid Specific Gravity 1.00 Water = 1 Vapor Pressure Head (ft) 0.839 Convert psi → ft 3.25 14.31 0.03 42.30
Fluid Temp (°F) 70.00 Atmospheric Head (ft) 33.957 Convert psi → ft 3.50 15.41 0.03 25.50
Vapor Pressure (psi) 0.363 70°F water Velocity Head (ft) 0.236 V²/2g 3.75 16.51 0.04 8.10
Atmospheric Pressure (psi) 14.70 Sea level NPSHa (ft) 33.354 Available NPSH
Pump Run Hours / Day 6.00 For energy calc NPSH Margin (ft) 31.354 Compare to required Operating Point
Allowable NPSH Margin (ft) 2.00 Safety NPSH Check OK Pass/fail Flow Rate (gpm) = 14.89 Pump NPSHr (ft) 5.00 From manufacturer Average Daily Flow (GPM) 3.723 Average over 24 hr Head (ft) = 10.21 Pump ON Level (ft) 7.90 Pond inlet
Pump OFF Level (ft) 17.75 Wetland outlet
Discharge Fittings (ft equiv)
Fitting Type Qty Equivalent Length (ft)
90° Elbow 3.00 4
45° Elbow 3.00 2
Check Valve 1.00 6 Total equivelant length 24
Pump Logic
Condition Action
Pond ≥ 7.9 ft AND Wetland < 17.75 ft Pump ON
Pond < 7.9 ft OR Wetland ≥ 17.75 ft Pump OFF
Pond < 7.9 ft (backup float) Pump OFF
Wetland ≥ 17.75 ft Pump OFF
OPERATING POINT
14.89 gpm (Flow)
10.21 ft (Head)
PRESSURE (LEVEL)
TRANSDUCER WIRING
TO UD-3.
· HIGH WATER PRESSURE (LEVEL) TRANSDUCER SHALL BE PLACED IN STRUCTURE UD-3.
· LOW WATER LEVEL PRESSURE (LEVEL) TRANSDUCER SHALL BE PLACED IN STRUCTURE S-2
DRAWN BY:
CHECKED BY:
SHEET NO.
PROJECT NO.
APPROVED BY:
ERIC K. NELSON, JR. P.E.
LIC. No. 79361
NO. DESCRIPTION
REVISIONS
C:\pw_work\american-pw-01\d0984264\RJCP_DRDT.dwg Apr 09, 2026 - 3:06pm
C
IT
Y
OF
P
AL
M B
AY
P U B
LI
C W
OR
K S
M
AL
AB
AR
R
OA
D P
AL
M B
AY
F L
DESIGNED BY:
P O N D I
M P R O V E M E N T S F
O R
R O B E R T J
C O N L A N D
R I V E P
O N D
P R E P
AR
E D B
Y:
C
YP
R E S S R
ID
GE
B
LV
D W E S
LE
Y C H
AP
E L, F
LO
R
ID
A
P H
ON
E (8
5-
EKN
12/11/2025
P U M
P D
E T A I L S
24FD09
EKN
12/11/2025
JAM
12/11/2025
| Sheets and Views |
| 1 KEY SHEET |
| 2 GENERAL NOTES |
| 3 EROSION CONTROL & DEMOLITION PLAN |
| 4 SITE LAYOUT |
| 5 CROSS SECTIONS |
| 6 WETLAND PLANTING PLAN |
| 7 SITE DETAILS |
| 8 DRAINAGE DETAILS |
| 9 PUMP DETAILS |
PDPL_RJCP-Cross Sections
| 2026-04-09T15:21:32-0400 | |
| Eric K Nelson | |
| I agree to the terms defined by the placement of my signature on this document |
File details come from the government source that posted it. Updated .