This document contains a series of product data sheets for architectural and industrial coatings from PPG Industries and Sherwin-Williams, including Break-Through! 250 Interior/Exterior Satin Water-Borne Acrylic, Pro Industrial Pre-Catalyzed Waterbased Epoxy, and Industrial Enamel Alkyd Gloss Enamel. These technical specification sheets provide comprehensive details about each product's characteristics, recommended uses, surface preparation requirements, application methods, compliance standards, performance specifications, and safety precautions. The documents are technical resources for professional painters, contractors, and industrial maintenance professionals, offering detailed guidance on product composition, application techniques, substrate compatibility, drying times, coverage rates, and recommended primers for various surfaces.
The product data sheets highlight key features such as adhesion properties, durability, chemical resistance, and specific performance metrics. Each coating is designed for different environments and substrates, with VOC compliance, various color options, and specific application temperature ranges. The sheets include technical data like volume solids, weight per gallon, coverage rates, drying times, and compliance with environmental and industry standards such as OTC, SCAQMD, CARB, and LEED. They also provide critical safety information, surface preparation guidelines, and cleanup instructions, demonstrating a comprehensive approach to product documentation that supports professional application and performance.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Architectural Coatings Break-Through! 250 Interior/Exterior Satin Water-Borne Acrylic
GENERAL DESCRIPTION
PRODUCT DATA
RECOMMENDED SUBSTRATES
A versatile, ultra-durable water-borne acrylic, Break-Through!, is formulated to bond to some of the most difficult substrates includ-ing fiberglass, ceramic tile, laminate, and many plastics. The interior/exterior satin finish offers very fast dry and outstanding early block resistance for increased productivity with less down time. Break-Through! provides hardness similar to or better than standard alkyds but maintains flexibility to endure extreme bends and deformation without cracking and peeling. Break-Through! is ideal for doors, windows, cabinets, shelving, hand rails, fixtures, trim, wood and concrete floors.
APPLICATION INFORMATION (continued)
CONFORMANCE STANDARDS
B5.2
APPLICATION INFORMATION
Break-Through!® V50-410 Series
VOC Compliant - lower than Federal AIM
Aluminum Galvanized Steel
Ceramic Tile Gypsum Wallboard-Drywall
Concrete Interior Wood
Concrete/Masonry Block Laminate
Ferrous Metal Plaster
Fiberglass Vinyl and Architectural Plastics
FEATURES / BENEFITS
Stir thoroughly before using and occasionally when in use.
Prime all necessary surfaces with an appropriate PPG primer prior to application of the product. When using more than one container of the same color, intermix to ensure color uniformity.
Do not mix with solvent-type paints or with paint solvents. USE
WITH ADEQUATE VENTILATION. KEEP OUT OF REACH OF
CHILDREN. Read all label and Material Safety Data Sheet
(MSDS) information prior to use. MSDS are available through our website or by calling 1-800-441-9695.
Application Equipment: Apply with a high quality synthetic brush, roller, paint pad, or by spray equipment. Where necessary, apply a second coat.
Airless Spray: Pressure 2000 psi, tip 0.009” - 0.013”. Best results are achieved using a fine finish tip.
Spray equipment must be handled with due care and in accordance with manufacturer’s recommendation. High-pressure injection of coatings into the skin by airless equipment may cause serious injury.
Brush: High quality polyester/nylon brush
Roller: 3/16” - 3/8” nap roller cover.
Thinning: No thinning required for airless or air-assisted airless application. Reduce 5-10% with clean water for conventional spray, HVLP and brush applications.
Features Benefits
Outstanding early block resistance Provides tack free film ideal for doors, windows, cabinets, shelving
Excellent adhesion Bonds to a wide variety of difficult substrates
Very good hardness Durability and hardness similar or better than conventional alkyds
Very quick dry Dry to touch in 15-20 minutes; results in less down time
Excellent flow & leveling Provides enamel smooth finish with less brush marks
Flexible Withstands bends with no cracking or peeling
Resistant to household chemicals Ideal for use in areas requiring frequent cleaning with mild household cleaners or light duty industrial cleaners
Permissible temperatures during application:
Material: 50 to 90ºF 10 to 32ºC
Ambient: 50 to 90ºF 10 to 32ºC
Substrate: 50 to 90ºF 10 to 32ºC
TINTING AND BASE INFORMATION
Refer to the appropriate color formula book, automatic tinting equipment, and/or computer color matching system for color formulas and tinting instructions. The bases can be tinted with 96 line or 896 colorants.
V50-410 White and Pastel Base
V50-420 Midtone*
V50-430 Deeptone*
V50-440 Ultra Deep*
V50-V Clear
V50-90 Wrought Iron Black
*Must be tinted before use.
Some colors, drastic color changes, or porous substrates may require more than one coat to achieve a uniform finish. Safety colors and high chroma colors should be tinted with 896 colorants for optimum performance.
PRODUCT TYPE: Water-borne Acrylic
SHEEN: Satin: 20 to 25 (60º Gloss Meter)
VOLUME SOLIDS*: 34% +/- 2%
WEIGHT SOLIDS*: 47% +/- 2%
VOC*: 250 g/L (2.1 lbs./gal.)
WEIGHT/GALLON*: 10.2 lbs. (4.6 kg) +/- 0.2 lbs. (91 g)
*Product data calculated on product V50-410.
COVERAGE: Approximately 400 sq. ft./gal. (37 sq. m/3.78L) depending on surface texture and porosity.
Wet Film Thickness: 4.0 mils
Wet Microns: 102 microns
Dry Film Thickness: 1.4 mils
Dry Microns: 36 microns
Coverage figures do not include loss due to surface irregularities and porosity or material loss due to application method or mixing.
DRYING TIME: Dry time @ 77ºF (25ºC); 50% relative humidity.
To Touch: 15 to 20 minutes
To Handle: 1 hour
To Recoat: After 2 hours
For Foot Traffic: 12 hours
For Forklift Traffic: 24 hours
To Full Cure: 7 days
Drying times listed may vary depending on temperature, humidity, color and air movement.
CLEANUP: Clean tools and spray equipment with warm, soapy water immediately after use.
DISPOSAL: Contact your local environmental regulatory agency for guidance on disposal of unused product. Do not pour down a drain or storm sewer.
FLASH POINT: Over 200ºF (93ºC)
Paints Attachment B
PPG V50-410 Series
GENERAL SURFACE PREPARATION
Architectural Coatings Break-Through! 250 Interior/Exterior Satin Water-Borne Acrylic
RECOMMENDED PRIMERS LIMITATIONS OF USE
Apply only when air and surface temperatures are above 50°F
(10°C) or above and when the air and surface temperatures will remain above 50°F (10°C) for the next 24 hours. Avoid exterior application late in the day when dew and condensation are likely to form or when rain is anticipated. Not recommended for exteri-or horizontal surfaces unless these surfaces can be protected from dew and rain for 7 days. Wait at least 7 days after painting before cleaning the surface with a non-abrasive, mild cleanser.
Not recommended for polypropylene or polyethylene plastics, roofs, garage floors or concrete floors subject to hot tires, continuous water immersion environments, such as bathtubs, sinks, shower basins and pools. Not recommended for very flexible substrates subject to abuse; such as canvas, nylon rope or rubber. Do not use on large wood structures or the bodies of homes. PROTECT FROM FREEZING.
Surfaces to be coated must be dry, clean, sound, and free from all contamination including loose and peeling paint, dirt, grease, oil, wax, concrete curing agents and bond breakers, chalk, efflorescence, mildew, rust, product fines, and dust. Remove loose paint, chalk, and efflorescence by wire brushing, scraping, sanding, and/or pressure washing. Putty all nail holes and caulk all cracks and open seams. Sand all glossy, rough, and patched surfaces. Feather back all rough edges to sound surface by sanding. Prime all bare and porous substrates with an appropriate primer. On exterior surfaces, remove mildew by using PPG MILDEW CHECK® Multi-Purpose Wash, 18-1; or 1 part chlorine bleach to 3 parts water. Before use, be sure to read and follow the instructions and warnings on the label. WARNING! If you scrape, sand, or remove old paint, you may release lead dust or fumes. LEAD IS TOXIC. EXPOSURE TO LEAD DUST OR FUMES CAN CAUSE
SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT WOMEN SHOULD ALSO AVOID EXPOSURE.
Wear a properly fitted NIOSH-approved respirator and prevent skin contact to control lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by contacting the USEPA National Lead
Information Hotline at 1-800-424-LEAD or log on to www.epa.gov/lead. In Canada contact a regional Health Canada office. Follow these instructions to control exposure to other hazardous substances that may be released during surface preparation.
Aluminum: A primer is required for proper adhesion. Any coating applied directly to aluminum should be spot applied, allowed to cure overnight, and then evaluated for adhesion. If adhesion is good, the application may proceed.
Ferrous Metal: The surface must be cleaned thoroughly to remove any dust, rust, oil and surface contaminants, and then primed. No primer is required for interior applications.
Galvanized Steel: A primer is required for proper adhesion. Caution must be used when selecting coatings for use on all galvanized metal surfaces. These substrates may have a factory-applied stabilizer, which is used to prevent white rusting during storage and shipping. Such stabilizers must be removed by either brush blasting, sanding or chemical treatment prior to priming.
Interior Wood: Unpainted wood or wood in poor condition should be sanded smooth, wiped clean, then primed. Any knots or resinous areas must be primed before painting. For non-bleeding or previously painted wood, no primer is required.
Concrete: New concrete should cure for at least 30 days and preferably 90 days prior to priming and painting. The pH of the substrate must be less than 10 before painting. If pH is greater than 10, prime with an alkali resistant primer.
Concrete/Masonry Block: Mortar should cure for at least 30 days and preferably 90 days prior to priming. Fill block with appropriate block filler. Surfaces previously coated with water thinned cement-based paint must be prepared with extra care. If the material appears to be adhering tightly, a masonry sealer may be applied to seal the surface.
Gypsum Wallboard/Drywall: Nails or screws should be countersunk, and they along with any indentations should be mudded flush with the surface, sanded smooth and cleaned to remove any dust, then prime prior to painting the substrate.
Plaster: Plaster or other alkaline surfaces should be allowed to cure for at least 30 days prior to priming with an alkali resistant primer.
Fiberglass: No primer needed; sanding or scuffing the surface is recommended. Primer and topcoat should be spot applied as directed, allowed to cure overnight, then evaluated for adhesion. If adhesion is good, the application may proceed.
Laminate: No primer needed; sanding or scuffing the surface is recommended. Topcoat should be spot applied as directed, allowed to cure overnight, then evaluated for adhesion. If adhesion is good, the application may proceed.
Ceramic Tile: No primer needed; sanding or etching with phosphoric acid is necessary. Topcoat should be spot applied as directed, allowed to cure overnight, then evaluated for adhesion. If adhesion is good, the application may proceed.
Vinyl & Architectural Plastics: Vinyl and similar architectural plastics may present potential adhesion problems. A primer may be required to promote proper adhesion. Consult the manufacturer’s guidelines prior to painting. Primer and Topcoat should be spot applied, allowed to cure overnight, then evaluated for adhesion. If adhesion is good, the application may proceed. Do not paint vinyl or plastic with a color dark-er than the original to prevent potential warping due to heat absorption.
PACKAGING
Aluminum 6-204, 17-921, 90-712, 90-912
Ceramic Tile Self-priming
Concrete 4-603, Self-priming
Concrete/Masonry Block 4-100, 6-7, 6-15
Ferrous Metal 6-208, 90-712, 90-912
Fiberglass Self-priming
Galvanized Steel 6-209, 17-921, 90-712, 90-912
Gypsum Wallboard/Drywall 6-2, 6-4, 9-900, 12-900
Interior Wood 6-2, 9-900, 17-921, 12-900
Laminate Self-priming
Plaster 4-603, 17-921
Vinyl & Architectural Plastics Self-priming
1-Gallon (3.78 L)
PPG Architectural Finishes, Inc. believes the technical data presented is currently accurate: however, no guarantee of accuracy, comprehensiveness, or performance is given or implied. Improvements in coatings technology may cause future techni-cal data to vary from what is in this bulletin. For complete, up-to-date technical infor-mation, visit our web site or call 1-800-441-9695.
PPG Industries, Inc.
Architectural Coatings
One PPG Place
Pittsburgh, PA 15272 www.ppgpittsburghpaints.com
Technical Services
1-800-441-9695
1-888-807-5123 fax
Architect/Specifier
1-888-PPG-IDEA
B5.2 8/2012
(Supersedes 2/2012)
PPG Canada, Inc.
Architectural Coatings
4 Kenview Blvd
Brampton, ON L6T 5E4
The PPG logo and Break-Through! are registered trademarks of PPG Industries Ohio, Inc.
MILDEW CHECK is a registered trademark of PPG Architectural Finishes, Inc.
113.40
Pro Industrial™
Pre-Catalyzed Waterbased Epoxy Eg-Shel K45-1150 Series
CHARACTERISTICS
Pro Industrial Pre-Catalyzed Waterbased Eg-Shel Epoxy is a single-component pre-catalyzed waterborne acrylic epoxy that offers the adhesion, durability and resistance to stains and most cleaning solvents usually characteristic of two-component waterborne acrylic epoxy products.
This product can be applied over a wide variety of primers on properly prepared interior metal, wood, masonry, plaster and drywall.
Features:
• Interior institutional - commercial high maintenance areas
| • | Upgrade surfaces painted with conventional coatings |
| • | High performance protection system with excellent |
adhesion
| • | Chemical resistant |
| • | Institutional dining and kitchen areas, Hospitals and |
Schools
• Suitable for use in USDA inspected facilities For use on properly prepared:
Steel, Galvanized & Aluminum, Concrete and Masonry, wood and drywall.
Finish: 15-25 units @60°
25-35 units @85° Color: Most colors Recommended Spreading Rate per coat:
Wet mils: 4.0 Dry mils: 1.4 Coverage: 400 sq.ft. per gallon Theoretical Coverage: 561 sq. ft. per gallon
@ 1 mil dry Note: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.
Drying Schedule @ 4.0 mils wet, @ 50% RH:
Drying, and recoat times are temperature, humidity, and film thickness dependent. * If this product dries 72 hours or longer it must be sanded before it is recoated
@77°F To Touch: 1 Hour
To Recoat: 8 hours Maximum recoat* 72+ hours
Full dry 5-7 days
Tinting with CCE only: Use SherColor Formulation System
Extra White K45W01151 (may vary by color)
V.O.C. (less exempt solvents):
less than 50 grams per litre; 0.42 lbs. per gallon
As per 40 CFR 59.406
Volume Solids: 35 ± 2% Weight Solids: 50 ± 2% Weight per Gallon: 10.57 lb Flash Point: N/A Vehicle Type: Acrylic Epoxy Shelf Life: 36 months, unopened
Mildew Resistant:
This coating contains agents which inhibit the growth of mildew on the surface of this coating film.
COMPLIANCE
As of 07/13/2020, Complies with:
OTC Yes OTC Phase II Yes SCAQMD Yes CARB Yes CARB SCM 2007 Yes Canada Yes LEED® v4 & v4.1 Emissions Yes LEED® v4 & v4.1 V.O.C. Yes EPD-NSF® Certified Yes MIR-Manufacturer Inventory No MPI® Yes
APPLICATION
Temperature:
minimum 50°F maximum 120°F air, surface, and material At least 5°F above dew point
Relative humidity: 85% maximum The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics.
Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: Not recommended Airless Spray:
Pressure 1800-2700 p.s.i.
Hose 1/4 inch I.D.
Tip .015 - .021 inch Filter 60 mesh Reduction Not recommended Brush Nylon-polyester Roller Cover 1/4-1/2 inch woven
If specific application equipment is listed above, equivalent equipment may be substituted.
Apply paint at the recommended film thickness and spreading rate as indicated. Application of coating above maximum or below minimum recommended spreading rate may adversely affect coating performance.
Not for use on surfaces continuously wet or under water, such as bath tubs, sinks, showers, or countertops. Not for floors.
SPECIFICATIONS
Steel:
1 coat Pro Industrial Pro-Cryl Primer or Kem Bonds HS 2 coats Pro Industrial Pre-Cat Epoxy Aluminum:
1 coat Pro Industrial Pro-Cryl Primer 2 coats Pro Industrial Pre-Cat Epoxy
Concrete Block (CMU):
1 coat Pro Industrial Heavy Duty Blockfiller or Loxon Acrylic Block Surfacer 2 coats Pro Industrial Pre-Cat Epoxy Concrete-Masonry:
1 coat Loxon Concrete & Masonry Primer or 1 coat Loxon Conditioner 2 coats Pro Industrial Pre-Cat Epoxy Drywall:
1 coat ProMar 200 Zero V.O.C. Primer 1-2 coats Pro Industrial Pre-Cat Epoxy Galvanizing:
1 coat Pro Industrial Pro-Cryl Primer 2 coats Pro Industrial Pre-Cat Epoxy Wood, interior:
1 coat Premium Wall and Wood Primer 2 coats Pro Industrial Pre-Cat Epoxy
The systems listed above are representative of the product’s use, other systems may be appropriate.
07/2020 www.sherwin-williams.com continued on back
Pro Industrial™
Pre-Catalyzed Waterbased Epoxy Eg-Shel
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Do not use hydrocarbon solvents for cleaning.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry.
Existing peeled or checked paint should be scraped and sanded to a sound surface. Glossy surfaces should be sanded dull. Stains from water, smoke, ink, pencil, grease, etc. should be sealed with the appropriate primer/sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Iron & Steel - Minimum surface preparation is Hand Tool Clean per SSPC-SP2. Remove all oil and grease from surface per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6.
Primer recommended for best performance. Prime any bare steel within 8 hours or before flash rusting occurs.
Aluminum - Remove all oil, grease, dirt, oxide and other foreign material per SSPC-SP1. Prime the area the same day as cleaned.
Galvanizing - Allow to weather a minimum of six months prior to coating. Solvent Clean per SSPC- SP1. When weathering is not possible, or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test patch. Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP16 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area the same day as cleaned.
Concrete Block - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F before filling. Use Pro Industrial Heavy Duty Block Filler or Loxon Acrylic Block Surfacer. The filler must be thoroughly dry before topcoating.
Masonry - All masonry must be free of dirt, oil, grease, loose paint, mortar, masonry dust, etc. Clean per SSPC-SP13/Nace 6/ ICRI No. 310.2R, CSP 1-3.
Poured, troweled, or tilt-up concrete, plaster, mortar, etc. must be thoroughly cured at least 30 days at 75°F.
Form release compounds and curing membranes must be removed by brush blasting. Brick must be allowed to weather for one year prior to surface preparation and painting. Prime the area the same day as cleaned. Weathered masonry and soft or porous cement board must be brush blasted or power tool cleaned to remove loosely adhering contamination and to get to a hard, firm surface. Apply one coat Loxon Conditioner, following label recommendations.
Wood - Surface must be clean, dry, and sound. Prime with recommended primer. No painting should be done immediately after a rain or during foggy weather.
Knots and pitch streaks must be scraped, sanded and spot primed before full coat of primer is applied. All nail holes or small openings must be properly caulked.
Sand to remove any loose or deteriorated surface wood and to obtain a proper surface profile.
Drywall - Fill cracks and holes with patching paste/ spackle and sand smooth. Joint compounds must be cured and sanded smooth. Remove all sanding dust.
Prime the area the same day as cleaned.
SURFACE PREPARATION
Previously Painted Surface - If in sound condition, clean the surface of all foreign material. Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary.
Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Mildew- Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water.
Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes.
Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach/water solution.
PERFORMANCE
Extra White K45W01151
System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation: SSPC-SP6 Finish: 1 coat Pro Industrial Pro-Cryl 1 coat Pro Industrial Pre-Cat Epoxy Adhesion: Darker colors require longer cure time for same level of adhesion Method: ASTM D3359 Result: 5B Pencil Hardness:
Method: ASTM D3363 Result: 2B Scrub Resistance: with Stiff Bristle Brush and Pumice Scrub Media, with shim Method: ASTM D2486 Result: 500-600 cycles Water Vapor Permeance (US):
Method: ASTM D1653 Result: 17.18 grains/(hr ft2 in Hg) Block Resistance: 7 day cure @ 3 mils D.F.T.
Method: Lab assessment Result: Excellent Chemical Resistance Rating:
(1 hour direct exposure to dry film 28 day cure) Distilled water room temperature-Excellent Ethanol-Excellent 10% Acetic Acid-Excellent 25% Sodium Hydroxide-Excellent 50% Sulfuric Acid-Excellent 5% Phosphoric Acid-Excellent 10% Hydrochloric Acid-Excellent Methanol-Excellent *Motor oil / Vegetable oil-Excellent *Mineral Spirits-Excellent *2 hour exposure
Stain Resistance Rating:
(1 hour direct exposure to dry film 4 day cure) Mustard-Excellent Grape Juice-Excellent Red Crayon-Excellent Lipstick, Red-Limited Ink-Limited Coffee-Excellent Tea-Excellent Ketchup-Excellent
SAFETY PRECAUTIONS
Before using, carefully read CAUTIONS on label.
Refer to the Safety Data Sheets (SDS) before use.
FOR PROFESSIONAL USE ONLY.
Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.
CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
HOTW 07/16/2020 K45W01151 07 40
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.
125.03
Industrial Enamel Alkyd Gloss Enamel B54-100 Series
CHARACTERISTICS
INDUSTRIAL ENAMEL is a medium oil-alkyd all-purpose enamel. Designed for interior and exterior use.
For use on properly prepared Steel, Concrete, Wood, Plaster, Previously painted, Primed Galvanized & Aluminum, Features:
| • | Good exterior durability |
| • | High Gloss |
| • | Excellent application properties |
| • | Exterior-Interior all-purpose enamel |
| • | Suitable for use in USDA inspected facilities |
Recommended for use in:
• Interior-exterior • New construction • Railings-frames • Machinery • Structural Steel • Steel doors • Steel supports • Equipment • Repaints • Storage tanks • Bar joists • Pipe marking • Fire escapes •Conveyors Color: Pure White, Deep, Ultradeep, Safety Colors and Black
Recommended Spreading Rate per coat:
Wet mils: 4.5-9.0 Dry mils: 1.9-3.9 Coverage sq. ft. per gallon: 176-362 Theoretical coverage: sq. ft.
per gallon @ 1 mil dry
Approximate spreading rates are calculated on volume solids and do not include any application loss. Note: Brush or roll application may require multiple coats to achieve maximum film thickness and uniformity of appearance.
Drying Schedule @ 4.6 mils wet, @ 50% RH:
@50°F @77°F @110°F
To touch 3 hours1-3 hours30 minutes Tack Free 8 hours4-6 hours 4 hours To recoat 12 hours 8 hours 3 hours To cure 7 days 7 days 3 days Drying, and recoat times are temperature, humidity, and film thickness dependent.
Tinting with BAC, Maxitoner or GIC:
Base oz. per gallon Strength Extra white 0-5 SherColor Deep Base 4-11 SherColor Ultradeep Base 10-11 SherColor
Check color before using. Five minutes minimum mixing on a mechanical shaker is required for complete mixing of color.
Finish: 80°+ @60° Gloss
Extra White B54W00101 (may vary by color)
V.O.C. (less exempt solvents):
441 grams per litre; 3.68 lbs. per gallon
As per 40 CFR 59.406
Volume Solids: 43 ± 2% Weight Solids: 58 ± 2% Weight per Gallon: 8.78 lb Flash Point: 101°F PMCC Shelf Life: 36 months, unopened
COMPLIANCE
As of 06/30/2021, Complies with:
OTC No OTC Phase II No S.C.A.Q.M.D. No CARB No CARB SCM 2007 No CARB SCM 2020 No Canada No LEED® v4 & v4.1 Emissions No LEED® v4 & v4.1 V.O.C. No EPD-NSF® Certified No MIR-Manufacturer Inventory No MPI® No
APPLICATION
Temperature:
minimum 40°F / 4.4°C maximum 120°F / 49°C air, surface, and material
At least 5°F above dew point Relative humidity: 85% maximum The following is a guide. Changes in pressures and tip sizes may be needed for proper spray characteristics.
Always purge spray equipment before use with listed reducer. Any reduction must be compatible with the existing environmental and application conditions.
Reducer: Not recommended
Airless Spray:
Pressure 2500 p.s.i.
Hose 1/4 inch I.D.
Tip .015 inch Filter 100 mesh Conventional Spray:
Gun Binks 95 Fluid Nozzle 66 Air Nozzle 63PB Atomization Pressure 50 p.s.i.
Fluid Pressure 20-25 p.s.i.
Brush Natural Bristle Roller Cover 3/8 inch woven with solvent resistant core If specific application equipment is listed above, equivalent equipment may be substituted.
Apply paint at the recommended film thickness and spreading rate as indicated. Application of coating above maximum or below minimum recommended spreading rate may adversely affect coating performance. Spreading rates are calculated on volume solids and do not include an application loss factor due to surface profile, roughness, or porosity of the surface, skill, and technique of the applicator, method of application, various surface irregularities, material lost during mixing, spillage, over thinning, climatic conditions, and excessive film build.
Mix paint thoroughly to a uniform consistency with slow speed power agitation prior to use.
Stripe coat crevices, welds, and sharp angles to prevent early failure in these areas.
When using spray application, use a 50% overlap with each pass of the gun to avoid holidays, bare areas, and pinholes. If necessary, cross spray at a right angle.
SPECIFICATIONS
Steel Alkyd Primer:
1 coat Kem Bond HS Primer or 1 coat Kem Kromik Universal Metal Primer 2 coats Industrial Enamel
Steel Acrylic Primer:
1 coat Pro Industrial Pro-Cryl Primer 2 coats Industrial Enamel
Aluminum:
1 coat DTM Wash Primer 2 coats Industrial Enamel
Galvanizing:
1 coat DTM Wash Primer 2 coats Industrial Enamel
Concrete Block:
1 coat Pro Industrial Heavy Duty Block Filler 2 coats Industrial Enamel
Plaster & Poured Concrete Walls, Interior:
1 coat Loxon Concrete and Masonry Primer 2 coats Industrial Enamel
Wood, Exterior:
1 coat Exterior Oil-Based Wood Primer 2 coats Industrial Enamel
Wood, Interior:
1 coat Premium Wall & Wood Primer 2 coats Industrial Enamel
Wood, floors:
2 coats Industrial Enamel
The systems listed above are representative of the product’s use, other systems may be appropriate.
Other primers may be appropriate.
06/2021 www.sherwin-williams.com continued on back
Industrial Enamel Alkyd Gloss Enamel
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Existing peeled or checked paint should be scraped and sanded to a sound surface. Glossy surfaces should be sanded dull. Stains from water, smoke, ink, pencil, grease, etc. should be sealed with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Iron & Steel - Minimum surface preparation is Hand Tool Clean per SSPC-SP2. Remove all oil and grease from surface by Solvent Cleaning per SSPC-SP1. For better performance, use Commercial Blast Cleaning per SSPC-SP6/NACE 3, blast clean all surfaces using a sharp, angular abrasive for optimum surface profile (2 mils). Prime any bare steel within 8 hours or before flash rusting occurs.
Aluminum - Remove all oil, grease, dirt, oxide and other foreign material per SSPC-SP1. Primer required.
Galvanizing - Remove all oil, grease, dirt, oxide and other foreign material by Solvent Cleaning per SSPC-SP1. When the surface has been treated with chromates or silicates, first Solvent Clean per SSPC- SP1 and apply a test patch. Allow paint to dry at least one week before testing adhesion. If adhesion is poor, brush blasting per SSPC-SP16 is necessary to remove these treatments. Rusty galvanizing requires a minimum of Hand Tool Cleaning per SSPC-SP2, prime the area the same day as cleaned. Primer required.
Concrete Block - Surface should be thoroughly clean and dry. Air, material and surface temperatures must be at least 50°F (10°C) before filling. Use Pro Industrial Heavy Duty Block Filler or Loxon Block Surfacer. The filler must be thoroughly dry before topcoating.
Masonry - All masonry must be free of dirt, oil, grease, loose paint, mortar, masonry dust, etc. Clean per SSPC-SP13/Nace 6/ ICRI No. 310.2R, CSP 1-3.
Poured, troweled, or tilt-up concrete, plaster, mortar, etc. must be thoroughly cured at least 30 days at 75°F(23.9°C). Form release compounds and curing membranes must be removed by brush blasting.
Brick must be allowed to weather for one year prior to surface preparation and painting. Weathered masonry and soft or porous cement board must be brush blasted or power tool cleaned to remove loosely adhering contamination and to get to a hard, firm surface. Apply one coat alkali resistant primer, following label recommendations. Primer required.
Drywall - Must be clean and dry. All nail heads must be set and spackled. Joints must be taped and covered with a joint compound. Spackled nail heads and tape joints must be sanded smooth and all dust removed prior to painting. Exterior surfaces must be spackled with exterior grade compounds.
Primer required.
Wood - Surface must be clean, dry, and sound.
Prime with recommended primer. No painting should be done immediately after a rain or during foggy weather. Knots and pitch streaks must be scraped, sanded and spot primed before full coat of primer is applied. All nail holes or small openings must be properly caulked. Sand to remove any loose or deteriorated surface wood and to obtain a proper surface profile. Primer required.
SURFACE PREPARATION
Previously Painted Surface - If in sound condition, clean the surface of all foreign material. Smooth, hard or glossy coatings and surfaces should be dulled by abrading the surface. Apply a test area, allowing paint to dry one week before testing adhesion. If adhesion is poor, additional abrasion of the surface and/or removal of the previous coating may be necessary.
Retest surface for adhesion. If paint is peeling or badly weathered, clean surface to sound substrate and treat as a new surface as above. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Mildew- Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised. Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach-water solution.
PERFORMANCE
Extra White B54W00101
System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation: SSPC-SP10 Primer: 1 coat Kem Bond HS @ 1.9 Mils D.F.T.
Finish: 1 coat Industrial Enamel @ 3.1 Mils D.F.T.
Abrasion Resistance:
Method: ASTM D4060 Result: 70 mg loss Adhesion:
Method: ASTM D4541 Result: 912 p.s.i.
Corrosion Weathering:
Method: ASTM D5894, 10 cycles Result: Rating 8, per ASTM D714 for Blistering. Rating 9 per ASTM D1654 for corrosion
Direct Impact Resistance:
Method: ASTM D2794 Result: 100 inch lb.
Dry Heat Resistance:
Method: ASTM D2485 Result: 200°F Flexibility:
Method: ASTM D522,1/8 inch mandrel Result: Pass Humidity Resistance:
Method: ASTM D4585, 500 hours Result: Rating 4 per ASTM D714 for blistering. Rating 10 per ASTM D1654 for corrosion
Pencil Hardness:
Method: ASTM-D3363 Result: 4H
Do not use colorants formulated for interior use only.
Deep tinted colors may exhibit burnishing characteristics.
SAFETY PRECAUTIONS
Before using, carefully read CAUTIONS on label.
Refer to the Safety Data Sheets (SDSs) before use.
FOR PROFESSIONAL USE ONLY.
Published technical data and instructions are subject to change without notice. Contact your Sherwin-Williams representative for additional technical data and instructions.
CLEANUP INFORMATION
Clean spills, spatters & tools with compliant cleanup solvent. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
DANGER: Rags, steel wool, other waste soaked with this product, and sanding residue may spontaneously catch fire if improperly discarded. Immediately place rags, steel wool, other waste soaked with this product, and sanding residue in a sealed, water-filled, metal container. Dispose of in accordance with local fire regulations.
HOTW 06/30/2021 B54W00101 51 441
| HOTW | 06/30/2021 B54W00113 15 443 | |
| HOTW | 06/30/2021 | B54T00104 35 444 |
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication. Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.
| breakthroughpdf |
| epoxy |
| industrial enemal |
File details come from the government source that posted it. Updated .