AMEND 00001 TCX.pdf

PDF 493 KB Posted

Attached to
Upgrade PLC System at FCC Tucson Federal contract opportunity
Solicitation number
15BFA023B00000036
Issued by
Department of Justice Bureau of Prisons Field Acquisition Office

About this file

This document is an amendment to a solicitation for an upgrade to the PLC system at the Federal Correctional Complex in Tucson, Arizona. The Bureau of Prisons issued solicitation number 15BFA023B00000036 to replace the existing PLCs and interface boards at the Admin Outside Building with new Omron CS1 redundant PLCs running SYSMAC CX programming, and to replace the PLCs and interface boards in all other buildings with new Omron CJ2 series PLCs also running SYSMAC CX programming. The amendment provides site visit meeting minutes and questions and answers as attachments, updates the statement of work to specify the new Omron PLC models and programming requirements, and replaces the existing construction wage determination with an updated version.

View the file

Other files for this federal contract opportunity

Other files attached to Upgrade PLC System at FCC Tucson, newest first.
File Type Posted
Bid Abstract.pdf PDF
Questions and Answer TCX.pdf PDF
Pre Bid Site Visit Meeting Minutes.pdf PDF
5 - Construction Wage Rate AZ20230040 09012023.pdf PDF
7 - Criminal History Check Form.pdf PDF
5 - Construction Wage Rate.pdf PDF
2 - Solicitation.pdf PDF
1 - Instructions to Bidders.pdf PDF
6 - Bid Bond SF24.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour a nd date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date sp ecified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or

(c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

D. OTHER (Specify type of modification and authority)

E. IMPORTANT:

Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force a nd effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

BY

(Signature of Contracting Officer)

16C. DATE SIGNED

PREVIOUS EDITION UNUSABLE

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

This form was electronically produced by Elite Federal Forms, Inc.

( ) A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.)

SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

1 2

00001 9/01/2023 15B61523PR000148 23Z6AK7

FAO

Federal Bureau of Prisons US Armed Forces Reserve Complex/FAO 346 Marine forces Drive Grand Prairie, TX 75051

FAO

Federal Bureau of Prisons US Armed Forces Reserve Complex/FAO 346 Marine forces Drive Grand Prairie, TX 75051

15BFA023B00000036

08/10/2023

FAO

See Block 14 Continuation Sheet(s)

Martin Guidry

15BFA023B00000036/00001

UPGRADE PLC SYSTEM

FCC TUCSON

The following changes are made to the Solicitation:

A. SITE VIST MEETING MINUTES (SEE ATTACHED).

B. QUESTIONS AND ANSWERS (SEE ATTACHED).

C. ADDENDUM STATEMENT OF WORK

1. ADD to Section B.1, “Contractor shall remove existing system and replace with new Omron CS1 Redundant PLC or equivalent at the Admin Outside Building, and a new Omron CJ2 series PLC or equivalent in all other buildings. Contractor will replace interface boards wired to every PLC in all buildings with a PLC.”

2. ADD to Section B.2, “The Contractor will provide a redundant PLC system which shall be an Omron CS1 Redundant PLC or equivalent in the Admin Outside building and a CJ2 series PLC or equivalent in all other buildings that have a PLC. The new PLC system will operate using SYSMAC CX programming, or approved equivalent.”

3. ADD to Section C.1, “Contractor shall disconnect and replace the existing redundant PLC with a new Bureau of Prisons approved Omron CS1 Redundant PLC running SYSMAC CX programming or approved equal and interface boards wired to PLC. Anything other than Omron CS1 and CJ2 PLC will need approval prior to the start of the project.”

4. REMOVE Section C.2.1, “J – USP Control Center (Administration): Replace all existing PLC 1/0 modules, power supplies, communication models and associated peripheral hardware located in the communication closet with new Omron CJ2 series running SYSMAC CX programming PLC 1/0 modules, chassis and interface boards wired to PLC or approved equivalent."

D. REMOVE EXISTING CONSTRUCTION WAGE RATE AZ20230032 AND REPLACE WITH AZ20230040

DATED 09/01/2023.

NO OTHER CHANGES ARE MADE AT THIS TIME.