This amendment modifies a solicitation for repair work at a federal correctional facility. The Federal Bureau of Prisons is seeking offers for a firm-fixed price contract to repair boiler refractory and replace six burner assemblies with ultra-low NOx models at FCC Victorville in California. Offerors must meet the $16.5 million small business size standard under NAICS code 238220. The performance period is 295 calendar days from notice to proceed. The amendment changes burner specifications and fuel requirements to allow for induced flue gas recirculation and separate secondary diesel fuel capability. It also replaces the construction wage determination.

View the file

Other files

File Type Posted
Abstract.pdf PDF
4 - Construction Wage Rate 06-12-2020.pdf PDF
Additional Question and Answer.pdf PDF
AMEND 0003 VIX.pdf PDF
7 - Additional Photos.pdf PDF
4 - Construction Wage Rate 05-29-2020.pdf PDF
Questions and Answer VIX.pdf PDF
AMEND 0002 VIX.pdf PDF
Pre-Bid Meeting Minutes Site Visit.pdf PDF
4 - Construction Wage Rate 05-15-2020.pdf PDF
AMEND 0001 VIX.pdf PDF
2 - Solicitation.pdf PDF
4 - Construction Wage Rate.pdf PDF
1 - Instructions to Bidders.pdf PDF
5 - SF24 Bid Bond.pdf PDF
6 - Criminal History Check Form.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) 9A. AMENDMENT OF SOLICITATION NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour a nd date specified for receipt of Offers is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date sp ecified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or

(c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

D. OTHER (Specify type of modification and authority)

E. IMPORTANT:

Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force a nd effect.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED 16B. UNITED STATES OF AMERICA

BY

(Signature of Contracting Officer)

16C. DATE SIGNED

PREVIOUS EDITION UNUSABLE

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

This form was electronically produced by Elite Federal Forms, Inc.

( ) A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.)

SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

1 1

00004 06/17/2020 0258-20 6D7A

FAO

Federal Bureau of Prisons US Armed Forces Reserve Complex/FAO 346 Marine forces Drive Grand Prairie, TX 75051

FAO

Federal Bureau of Prisons US Armed Forces Reserve Complex/FAO 346 Marine forces Drive Grand Prairie, TX 75051

15B61620B00000001

04/27/2020

FAO

AMENDMENT IS AS FOLLOW:

SEE PAGE 2 FOR REQUIRED CHANGES. ENSURE ALL ITEMS ARE READ AND UNDERSTOOD

THOROUGHLY.

NO OTHER CHANGES ARE MADE AT THIS TIME.

Martin Guidry

SOLICITATION: 15B61620B00000001

AMENDMENT: 00004

REPAIR BOILER REFRACTORY

FCC VICTORVILLE – PROJECT 6D7A

The following changes are made:

STATEMENT OF WORK:

Option 1: Replace Six Burner Assemblies with Ultra Low NOx Burner Assemblies - Contractor shall provide and install equipment that meets the following specifications:

3. Changed: The burner shall operate with induced flue gas recirculation (IFGR) with natural gas as the main (primary) fuel, to maintain combustion a 5.0% excess 02 at high fire. A servo motor shall control the positioning of the IFGR inlet damper. Existing IFGR lines will be used when possible. A separate secondary fuel burner/head assembly which utilizes diesel will be provided.

Current fuel pumps and compressors may be re-used if compatible.

31. Changed: A separate secondary diesel fuel burner/head assembly consisting of the following:

a. Self-Cleaning Oil Nozzle Assembly with oil and atomizing air trains.

b. Gas/Oil Selector System.

c. Main and Auxiliary Oil Solenoid Shut-off Valves.

d. 1/2” Proof of Closure Oil Valve.

e. Atomizing air compressor.

REMOVE EXISTING CONSTRUCTION WAGE RATE AND REPLACE WITH CA20200026 DATED

06/12/2020, MODIFICATION 7.

QUESTIONS AND ANSWERS: