RPM SPECIFICATIONS OF THE CENTRIFUGAL WATER PUMPS FOR EXISTING BOILERS.docx
DOCX document 13 KB Posted
- Attached to
- CENTRIFUGAL WATER PUMPS FOR EXISTING BOILERS
- Solicitation number
- 15B21626Q00000003
About this file
This document is a specifications list for centrifugal water pumps required for the Federal Bureau of Prisons Federal Correctional Institution in Elkton, Ohio. The file details 16 replacement pumps divided into two categories: nine hot loop pumps (models 8P-4 through 10-P10) operating at RPM ranges of 1465-1760, and seven chilled water pumps (models 8P-13 through 10-P6) operating at RPM ranges of 1760-1775. All pumps must be Variable Frequency Drive (VFD) compatible to meet the facility's operational requirements for the boiler system that delivers heated water throughout the institution.
The accompanying solicitation 15B21626Q00000003 is a firm-fixed-price procurement restricted to 100% Small Business Concerns, with FOB Destination terms and award to be made to the responsible offeror offering the most advantageous proposal to the Government, with price weighted higher than past performance. The solicitation was made available on or after March 17, 2026, through sam.gov exclusively, with quotes due by March 24, 2026, at 10:00 a.m. Eastern Time via email only to zbowers@bop.gov. Contractors must be registered in the System for Award Management (SAM) database, and payment will be made through Electronic Funds Transfer (EFT).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF1449 BF Project 26Z2AR7 Replace Powerhouse and FSL Pumps.pdf | ||
| 26Z2AR7 Statement of Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hot loop pumps
8P-4 - 1470 RPM - (Needs to be VFD compatible) 8P-5 1470 RPM - (Needs to be VFD compatible) 8P-6 1470 RPM - (Needs to be VFD compatible) 8P-7 1745 RPM - (Needs to be VFD compatible) 8P-8 1745 RPM - (Needs to be VFD compatible) 10-P7 1760 RPM - (Needs to be VFD compatible) 10-P8 1760 RPM - (Needs to be VFD compatible) 10-P9 1760 RPM - (Needs to be VFD compatible) 10-P10 1465 RPM - (Needs to be VFD compatible)
Chilled water pumps
8P-13 1770 RPM - (Needs to be VFD compatible) 8P-14 1770 RPM - (Needs to be VFD compatible) 8P-15 1775 RPM - (Needs to be VFD compatible) 8P-16 1775 RPM - (Needs to be VFD compatible) 10-P5 1760 RPM - (Needs to be VFD compatible) 10-P6 1760 RPM - (Needs to be VFD compatible)
File details come from the government source that posted it. Updated .