ASPHALT PACKAGE -1-2025
UPIN NO. 25103MF3MV01
PROJECT
AREA
ROAD LOGS: 3346331, 32387A0, 32387A1
PROJECT
AREA
PROJECT
AREA
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
GENERAL
PLAN AND DETAIL SHEETS
TRAFFIC CONTROL
STORM WATER POLLUTION PREVENTION PLANS
SIGNING AND PAVEMENT MARKING PLANS
PROJECT SIGN
HARRIS
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
20. CONTRACTOR SHALL NOTIFY THE KLEIN FIRE DEPARTMENT STATION 34 (16812 SQUYRES ROAD, SPRING, TEXAS) A MINIMUM 48 HOURS IN
ADVANCE OF BEGIN OF CONSTRUCTION OPERATIONS.
18. ALL INTERSECTIONS MUST BE REPAVED WITHIN 72 HOURS. NO MAIN LANES SHALL BE EXPOSED TO CROSS TRAFFIC WITHOUT A TEMPORARY TRANSITION.
6/18/25
LEGEND
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
CL PROP. PAVEMENT
E .P
MILLING/OVERLAY SURFACE WIDTH VARIES
6" MAX
ASPHALT
TACK COAT
8"-BLACK BASE
REPAIR (AS
REQUIRED)
SEE TAPER, EDGE
DETAIL, SHEET 07
VARIES VARIES
PROP 2" MILLING AND 2" HMAC
ASPHALTIC CONCRETE
SURFACE (TYPE "D")
BASE DEPTH VARIES
8"-BLACK BASE REPAIR
(AS REQUIRED)
EXIST
SUBGRADE
AREA
SUITABLE MATERIAL FOR
SUBGRADE REPAIR IF
REQUIRED.
E .P
ASPHALT
PRIME COAT
ASPHALT
PRIME COAT
ASPHALT
TACK COAT
CL EXIST. PAVEMENT
EXIST. PAVEMENT WIDTH VARIES
E .P
E .P
.EXISTING ASPHALT
PAVEMENT DEPTH VARIES
AS PER GEOTECHNICAL
REPORT
EXIST
ROADSIDE
DITCH EXIST
ROADSIDE
DITCH
PROPOSED TYPICAL SECTION (MILLING AND OVERLAY)
EXISTING TYPICAL SECTION
SCALE: 1"=1.5'
REFER TO NOTE 7 +/- 1/4"/FT+/- 1/4"/FT
SCALE: 1"=1.5'
REFER TO NOTE 7
REFER TO NOTE 7
REFER TO NOTE 7
VARIES VARIES
NOTES:
1. PROPOSED SURFACE TO MATCH EXISTING.
NO NET FILL IN FLOODPLAIN.
2. REMOVE AND DISPOSE OF UNSUITABLE
MATERIALS DISCOVERED DURING
RECONSTRUCTION PROCESS AND REPLACE
WITH SUITABLE MATERIALS.
3. CONTRACTOR TO CALL 811 AND IDENTIFY
ALL UTILITY CROSSINGS.
4. NO BASE REPAIR TO BE PERFORMED 25 FT
EITHER SIDE OF A PIPELINE.
5. REFER TO GEOTECHNICAL INVESTIGATION
FOR ASPHALT RECONSTRUCTION PROJECT.
6. ANY WORK WITHIN 200 FT. OF A SIGNALIZED
INTERSECTION REQUIRES COORDINATION
WITH HARRIS COUNTY ENGINEERING
DEPARTMENT, TRAFFIC SIGNAL
MAINTENANCE GROUP. THE CONTRACTOR
SHALL CALL TRAFFIC SIGNAL MAINTENANCE
AT (713) 881-3210 TWO WEEKS PRIOR TO
THE START OF CONSTRUCTION.
7. CONTRACTOR SHALL COMPLY WITH
PAVEMENT STRIPING DETAILS (EDGE
STRIPING ,LANE STRIPING, C/L STRIPING
REFER TO SHEETS 25 & 26).
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M
A T
C H
L
IN
E
S T
A
M A
T C
H L
IN
E
S
T A
B E
G
IN
C O
N S
T R
U C
T
IO
N W
O R
K L
IM
IT
7/8/25
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M
A T
C H
L
IN
E
S T
A
M A
T C
H L
IN
E
S
T A
M
A T
C H
L
IN
E
S T
A
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M
A T
C H
L
IN
E
S T
A
LEGEND
E N
D C
O N
S T
R U
C T
IO
N
W O
R K
L
IM
IT
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H
LIN
E
S T
A 16+
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
B E
G
IN
C O
N S
T R
U C
T
IO
N W
O R
K L
IM
IT
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M A
T C
H
LIN
E
S T
A . 40+
M A
T C
H L
IN
E
S
T A
. 4
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
M A
T C
H L
IN
E
S
T A
M
A T
C H
L
IN
E
S T
A
M A
T C
H L
IN
E
S
T A
. 6 4+
M A
T C
H L
IN
E
S
T A
.7
M A
T C
H
LIN
E
S T
A . 64+
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
S
T A
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
M A
T C
H L
IN
E
M A
T C
H L
IN
E
LEGEND
R .O
.W
© 2025 Micro soft C orporation © 2025 Maxar ©
CNES (2025) D
istr ibution Airbus D
S
HARRIS COUNTY
ENGINEERING DEPARTMENT 2107 CITYWEST BLVD, 3RD FLR I HOUSTON, TX 77042 I 713.428.2400
TEXAS ENGINEERING FIRM #470 I TEXAS SURVEYING FIRM #10028800
LEGEND
M A
T C
H L
IN
E
M A
T C
H
LIN
E
R .O
.W
28 29
ENGINEER'S CERTIFICATION
FLOOD PLAIN STATUS
DESCRIPTION OF PROPERTY
COMMERCIAL / OTHER SITE DRAINAGE WATER AND WASTEWATER
HARRIS COUNTY
ENGINEERING DEPARTMENT
REVIEW SHEET
PAVING
DRIVEWAYS (in H.C. ROW only)
TRAFFIC CONSIDERATIONS
RESIDENTIAL / SUBDIVISION DRAINAGE1. 3. 4.
5.
2.
7.
CURBING
FIRE APPARATUS ACCESS ROAD
CURB RAMPS 8.
(2001 ADJ.)
6. STORMWATER QUALITY
LANDSCAPING 9.
PERMITS REQUIRED10.
WORK IN HARRIS COUNTY R.O.W.
FOR PROJECTS LOCATED IN ANY FLOODPLAIN
Development constructed or placed in accordance with these plans will comply with all provisions of the Regulations of Harris County, Texas for Floodplain Management.
No net fill is allowed in the flood plain and no fill is allowed in the floodway.
FOUNDATION NOTES: (Applies to only buildings or building additions requiring a class II permit) All water heaters, furnaces, air conditioning units, electrical distribution panels, and any other mechanical or electrical equipment must be elevated in accordance with Section 4.05 of Harris County Floodplain regulations.
Any electrical circuit serving a light switch or outlet located below the base (100-year) flood elevation shall be dropped from above and be on a separate breaker.
All materials used below the (100-year) base flood elevation are on approved FEMA Technical Bulletin 2-08 as Class 5 water-resistant, and approved in accordance with FEMA Technical Bulletin 1-08 for foundation openings.
Critical facilities located in the 0.2% or 500yr floodplain or 1% or 100yr floodplain shall have the lowest floor elevated to 3 feet or more above the 0.2% flood elevation, or 24 inches above the crown of the adjacent road, which ever results in a higher elevation.
Floodproofing and sealing measures must be taken to ensure that toxic substances will not be displaced by or released into floodwaters.
Access routes elevated to or above the level of the base flood shall be provided to all critical facilities to the extent possible.
A completed as-built certificate must be submitted after the structure is complete and before it is occupied.
The County Engineer's Office will post a final inspection notice on the structure once all requirements have been met.
No fill may be used to elevate structures in the 1% or 100yr flood plain. Structures may be constructed on an open foundation, such as piers, or on continuous foundation walls with properly sized and located openings. All foundations are required to be designed by a registered professional engineer.
All structures shall be designed to withstand a three second gust basic wind speed of 120mph.
Completed *Elevation Certificates to be submitted: one at permitting, a second after the slab is poured or sub-floor is installed and before the framing starts, and a third is required once construction is finished. *(PER CURRENT FIRM PANEL) to the Harris County Engineering Department, 10555 Northwest Freeway, Suite 120, Houston, TX 77092
IF YES, CHECK THE BOX THAT APPLIES TO THIS PROJECT
NOTE: ALL EXISTING AND PROPOSED UTILITIES MUST BE
ACCURATELY SHOWN & LABELED ON THE SITE PLANS.
NOTE: SEPTIC SYSTEMS REQUIRE H.C. WASTE WATER REVIEW
NOTE: PUBLIC UTILITIES REQUIRE A LETTER FROM THE DISTRICT/
MUNICIPALITY AUTHORIZING SERVICE & CONNECTION.
THIS IS REQUIRED FOR PLAN APPROVAL.
NOTE: ALL ROADSIDE DITCH OUTFALLS REQUIRE EROSION CONTROL MEASURES.
RIPRAP IS NOT ALLOWED AS AN EROSION CONTROL MEASURE IN HARRIS COUNTY ROW.
ALL PUMPED DETENTION OUTFALLS TO ROADSIDE DITCHES REQUIRE MANHOLE W/ LEADS.
DOES THE PROPERTY HAVE ANY VIOLATIONS? IF SO PLEASE PROVIDE
ALL VIOLATION NUMBERS.DESIGN
THICKNESS
OF PAVING
STABILIZED
SUBGRADE
DEPTH
DESIGN
STRENGTH
OF CONCRETE
STEEL SPACING
LONG. TRANS.
(IN.) (IN.) (PSI) (IN.) (IN.)
NOTE: ALL APPROVED, FINAL PLATS AND ASSOCIATED
CPC101 FORMS MUST BE INCLUDED WITH PLAN SUBMITTAL.
OFFSITE SHEET FLOW: (100 YEAR)
OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, AND
DESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTED
IN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.
TOTAL ACREAGE = _____
TOTAL DISCHARGE = _____
NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BE
IDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNING
ENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.
NOTE: A COPY OF TCEQ APPROVAL FOR PRIVATE WATER &
WASTE WATER SYSTEMS IS REQUIRED FOR PLAN APPROVAL.
BENCHMARK REQUIREMENTS FOR
PROPOSED BRIDGES AND OR NEW RESIDENTIAL SUBIDIVSIONS
When the County Engineer has determined that a new benchmark will be required to be established for the proposed project, the developer shall be required to install a benchmark per section 8.0, part 2 of the Harris County Infrastructure Regulations.
Is a new Benchmark required for this project? (to be determined by Harris County) [__] yes [__] no
If a new Benchmark is required, the proposed benchmark information is shown on sheets ____
NOTE: DEDICATED UNDERGROUND FIRE LINES MUST BE SUBMITTED TO
THE HARRIS COUNTY FIRE PROTECTION GROUP FOR REVIEW AND
PERMITTING BY THE UNDERGROUND FIRE LINE CONTRACTOR. CIVIL
REIVEW DOES NOT REVIEW OR APPROVE UNDERGROUND FIRE LINES FOR
THE FIRE PROTECTION SYSTEMS.
(#4 MIN.)
REINFORCE
STEEL
SIZE
WASTEWATER TREATMENT PLANTS
IS THE PROPOSED PROJECT A NEW WWTP SITE OR A REHAB/EXPANSION OF AN
EXISTING WWTP SITE? YES NO
IF YES, IS A HARRIS COUNTY DOMESTIC WASTEWATER TREATMENT PLANT EXPRES
REVIEW SHEET ATTACHED AND COMPLETED ACCORDING TO INSTRUCTIONS?
YES NO
REFER TO:
WWW.ENG.HCTX.NET/PERMITS/WASTEWATER/REGULATIONS-STANDARDS-DETAILS
FOR DOMESTIC WWTP ERS FORM
HARRIS COUNTY ENGINEERING DEPARTMENT -
PERMIT OFFICE NOTE:
THE PERMIT MANAGER SIGNATURE REPRESENTS
THE FOLLOWING:
· THE COMPLETION OF REVIEW OF THESE
PLANS
· INTERPOSE NO OBJECTION TO THE PROPOSED
DESIGN ON PRIVATE PROPERTY
· APPROVAL OF WORK IN HARRIS COUNTY
MAINTAINED RIGHT OF WAY
· APPROVAL OF WORK IN PROPOSED HARRIS
COUNTY RIGHT OF WAY THAT IS TO BE
ACCEPTED BY THE COUNTY
DESIGN
SURFACE
COURSE
THICKNESS
(IN.) (IN.) (IN.)
DESIGN
SURFACE
COURSE
TYPE
DESIGN
BASE
COURSE
THICKNESS
DESIGN
BASE
COURSE
TYPE
STABILIZED
SUBGRADE
THICKNESS
(MATERIAL) (MATERIAL) (MATERIAL)
STABILIZED
SUBGRADE
TYPE
C O
N C
RE
TE
AS
PH
AL
T
2 8HMAC BLACK BASE
2504110054 2504110059
29 29
1 29
ENGINEER'S CERTIFICATION
4. FLOOD PLAIN STATUS
HARRIS COUNTY
FLOOD CONTROL DISTRICT
REVIEW SHEET
HARRIS COUNTY FLOOD CONTROL DISTRICT
2. SITE DETENTION DRAINAGE
(2001 ADJ.)
5. WORK IN HCFCD RIGHT-OF-WAY
1. PROPERTY DESCRIPTION
OFFSITE SHEET FLOW: (100 YEAR)
OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, AND
DESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTED
IN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.
TOTAL ACREAGE = _____
TOTAL DISCHARGE = _____
NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BE
IDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNING
ENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.
HCFCD SIGNATURE BLOCK
3. SWQ DISCHARGE INTO FCD FACILITY
6. REPORTS/AGREEMENTS
FOR PROJECTS LOCATED IN ANY FLOODPLAIN
Development constructed or placed in accordance with these plans will comply with all provisions of the designated Floodplain Administrator.
No net fill is allowed in the flood plain and no fill is allowed in the floodway.
2504110059