146th_and_Hazel_Dell_Plans_For_Bridge_335_Plans.pdf
PDF 15 MB Posted
- Solicitation number
- PR-26-0836
- Issued by
- Hamilton County, Indiana
About this file
This document is a comprehensive set of bridge construction plans prepared by CHA Consulting, Inc. for the Indiana Department of Transportation (INDOT) and Hamilton County for the new Bridge No. 335, which carries 146th Street over Hazel Dell Parkway in Clay and Noblesville Townships. The project involves construction of a continuous composite prestressed concrete bulb-tee beam bridge with three spans (103 feet, 85 feet, and 103 feet) totaling approximately 292.5 feet. The bridge features two 32-foot clear roadways with 6-foot shoulders, a 4-foot median, and modified PF-1 type bridge railing. The structure will be supported by two interior piers (Piers 2 and 3) and two end bents (Bents 1 and 4) founded on 14-inch steel pipe piles with conical tips. The project file includes detailed specifications for nine prestressed concrete beams, reinforced concrete deck slabs, elastomeric bearing assemblies, and related appurtenances, along with complete construction details, reinforcement schedules, and material quantities across 37 sheets of technical drawings dated 07/22/2026.
The bridge design accommodates HL-93 live loading per AASHTO LRFD specifications with a design speed of 45 miles per hour for the main intersection and 20-45 miles per hour for ramps. Concrete specifications include Class A (3,500 psi), Class B (3,000 psi), and Class C (4,000 psi) materials. All reinforcing steel shall be galvanized, including approximately 156,730 pounds in the superstructure and additional quantities in substructure elements. The project includes utility coordination with multiple agencies including Duke Energy, CenterPoint Energy, Comcast, Charter Communications, Zayo Group, MCI Verizon, Bluebird Fiber, the City of Carmel, and the Town of Noblesville regarding water, sewer, gas, electric, and communications line relocations. Earthwork quantities total approximately 1,200 cubic yards of excavation and 1,050 cubic yards of borrow material, with surface seal specifications for exposed concrete surfaces. The contract documents reference coordination with a parallel KIN Project roadway construction and indicate sequenced concrete deck pours to manage dead load deflection effects.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
IM
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
:V
P ro je c ts
\A N
Y \K
\0
.0
\0
D e s ig n \D ra w in g s \0
S h e e ts
\0 S h t
T it le .d g n
T it le S h t
/2
/2
:4
:0
P
M
PROJECT
DESIGNATION
SHEETS
of
BRIDGE FILE
PHONE NUMBER
317.786.0461
INDIANA DEPARTMENT OF TRANSPORTATION
FOR LETTING:
APPROVED
CERTIFIED BY:
PREPARED BY:
PLANS
CHA Consulting, Inc.
DATE
PR-26-0836
Bridge No. 335
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107 07/22/2026
P.E.
R/W
CONST.
BRIDGE PLANS
BRIDGE FILE
PROJECT NO. PR-26-0836
PROJECT LOCATION SHOWN BY
PROJECT DESIGNATION
CONTRACT
STRUCTURE TYPE SPAN AND SKEW OVER STATION
ROUTE: 146TH ST. OVER HAZEL DELL PKWY.
FOR SPANS OVER 20 FEET
TO BE USED WITH THESE PLANS.
DATEDSTANDARD SPECIFICATIONS
INDIANA DEPARTMENT OF TRANSPORTATION
TOTAL LENGTH:
BRIDGE LENGTH:
ROADWAY LENGTH:
MAX. GRADE: %
MI.
MI.
MI.
40°00'00" N 86°04'35" WLATITUDE: LONGITUDE:
0.06
0.89
0.89
5.71
STRUCTURE INFORMATION
No. 335 Hamilton County Bridge
Concrete Bulb-Tee Beam Continuous Composite
113'-0", 85'-0", 113'-0" Three Spans
Hazel Dell Pkwy. 37+25.28 "PR-A"
PR-26-0836
Bridge No. 335
KIN PROJECT INFORMATION
PROJECT PROJECT DESCRIPTION
PR-26-0836 (Lead) Roadway and other plans for project
Township 18 North, Range 4 East, Clay Township All In Hamilton County, Indiana.
Sections 15 & 16, Township 18 North, Range 4 East, Noblesville Township & Sections 21 & 22, of a New Grade Separated Interchange. Project is Located in
New Bridge Construction carrying 146th St. Over Hazel Dell Pkwy. as part
317.786.0461 · www.chasolutions.com
Indianapolis, IN 46204
201 N. Illinois Street, Suite 800
Drawing Copyright © 2026
LOCATION MAP
Hamilton County
SCALE: 1" = 1000'
R-4-E
T -1
-N
NEW BRIDGE CONSTRUCTION
HAMILTON COUNTY BRIDGE NO. 335
O.P.O.T. Sta. 16+00.00 "A", 4.01' Rt.
P.O.T. Sta. 16+00.00 "PR-A" =
BEGIN PROJECT
O.P.O.T. Sta. 13+39.53 "B", 9.07' Rt.
P.O.T. Sta. 13+39.53 "PR-B1" =
BEGIN CONSTRUCTION
O.P.O.T. Sta. 25+77.46 "B", 0.83 Rt.
P.O.T. Sta. 25+77.46 "PR-B2" =
END CONSTRUCTION
O.P.O.T. Sta. 57+34.70 "A", 19.19' Rt.
P.O.C. Sta. 57+36.98 "PR-A" =
END PROJECT
BEGIN:
END:
LATITUDE: 40°00'00" N LONGITUDE: 86°03'54" W
Carmel Water PlansPR-26-0836 (Kin)
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
:V
P ro je c ts
\A N
Y \K
\0
.0
\0
D e s ig n \D ra w in g s \0
S h e e ts
\0 S h t
In d e x .d g n
In d e x S h t
/2
/2
:5
:3
M
FOR APPROVAL
RECOMMENDED
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
BRIDGE FILEHORIZONTAL SCALE
HIGHWAY DEPARTMENT
HAMILTON COUNTY
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
INDEX AND NOTES
INDEX
SHEET NO. SUBJECT
1 TITLE
2 INDEX
3-5 SOIL BORINGS
6 LAYOUT
7-8 GENERAL PLAN
9-11 END BENT DETAILS
12-15 PIER DETAILS
16 FRAMING PLAN
17-19 BEAM DETAILS
20-21 BEARING DETAILS
22-28 SUPERSTRUCTURE DETAILS
UTILITIES
COMMUNICATIONS:
Ph: 317-459-4769
Indianapolis, IN 46204
240 N. Meridian St.
REVISIONS
REVISEDDATESHEET NO.
Email: byron.posey@charter.com
Ph: 317-538-2016
Indianapolis, IN 46218
3030 Roosevelt Ave.
Charter Comm./Spectrum
Ph: 317-417-7322
Email: Brenden_Kline@comcast.com
Comcast
Email: frank.lenihan@zayo.com
Ph: 585-233-4761
Indianapolis, IN 46225
800 Oliver Ave., Suite 1
Crown Castle (now Zayo)
Ph: 317-213-3137
Email: mpugh@everstream.net
Bluebird Fiber
Email: chris.reed@verizon.com
Ph: 317-408-3971
Indianapolis, IN 46225
720 W. Henry St.
MCI Verizon
Email: doug.reckart@metronet.com
Ph: 317-599-1191
Indianapolis, IN 46239
8036 Cole Wood Blvd.
Metronet Inc.
Email: Waylon.higgins@zayo.com
Ph: 765-341-1199
Indianapolis, IN 46256
9209 Castlegate Dr.
Zayo Group
ELECTRIC:
Email: zach.lewis@duke-energy.com
Ph: 317-951-3265
Noblesville, IN 46062
100 S. Mill Creek Rd.
Duke Energy
WATER & SEWER:
Email: scook@carmel.in.gov
Ph: 317-733-2849
Carmel, IN 46032
30 W. Main St.
City of Carmel
Ph: 317-927-4434
Indianapolis, IN 46202
GAS:
Email: publicproject@CenterPointEnergy.com
Ph: 765-287-2119
Muncie, IN 47302
1800 W. 26th St.
CenterPoint Energy
WATER:
Email: kparker@noblesville.in.us
Ph: 317-776-6353
Noblesville, IN 46060
197 Washington St.
STORM SEWER:
N/A
N/A
TPH TPH
JPL JPL
Email: rshultz@eegosp.com
Ph: 815-741-4951
Zayo, Metronet & Bluebird)
Email: jstewart@carmel.in.gov
Carmel, IN 46032
30 W. Main St.
City of Carmel
Email: dbye@crossroadengineers.com
Beech Grove, IN 46107
3417 Sherman Dr.
Crossroads Engineers
A.A.D.T.
A.A.D.T.
D.H.V
DIRECTIONAL DISTRIBUTION
TRUCKS
DESIGN SPEED
PROJECT DESIGN CRITERIA
FUNCTIONAL CLASSIFICATION
RURAL/URBAN
TERRAIN
ACCESS CONTROL
V.P.D.
V.P.D.
V.P.H.
146th St.
DESIGN DATA
(2026)
(2046)
(2046)
TRAFFIC DATA
32,211
Hazel Dell Pky. Ramp "A-SWR" Ramp "A-SER" Ramp "A-NER" Ramp "A-NWR"
40,582
3,652
56% EB / 44% WB
2-3% D.H.V.
20,526
25,828
2,325
55% EB / 45% WB
1-3% D.H.V.
5,792
7,290
100%
1% D.H.V.
4,374
5,414
100%
3% D.H.V.
4,537
5,476
100%
2% D.H.V.
4,864
6,148
100%
2% D.H.V.
146th St. Hazel Dell Pky. Ramp "A-SWR" Ramp "A-SER" Ramp "A-NER" Ramp "A-NWR"
45 M.P.H.
Reconstruction (4R)
Principal Arterial
Urban (Built Up)
Level
Partial
45 M.P.H.
Reconstruction (4R)
Principal Arterial
Urban (Built Up)
Level
Partial
20-45 M.P.H.
Reconstruction (4R)
Ramp
Urban (Built Up)
Level
Partial
20-45 M.P.H.
Reconstruction (4R)
Ramp
Urban (Built Up)
Level
Partial
20-45 M.P.H.
Reconstruction (4R)
Ramp
Urban (Built Up)
Level
Partial
20-45 M.P.H.
Reconstruction (4R)
Ramp
Urban (Built Up)
Level
Partial
29-30 SCREEDS
31-34 RAILING DETAILS
35-36 APPROACH SLAB DETAILS
37 BRIDGE SUMMARY
before you dig. Call below.Know what's
24 HOURS A DAY 7 DAYS A WEEK
1-800-382-5544 OR CALL 811
INDIANA UNDERGROUND
36+00
37+00
38+00
39+00
35+00
S 87° 18' 05" E
TIME PLO
TTED:
DATE PL
OTTED:
MODEL N
AME:
PATH AN
D FILENA
ME:
$FILEL$
$MODELN
AME$
$DATE$
$TIME$
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
BORING PLAN
Scale: 1" = 40'-0" sampler 6 in., using a 140-lb. hammer whit a free fall height of 30-in.
Blow Counts refer to the number of blows required to drive a 2-in. O.D. split barrel
NOTE:
58.0' Rt.
STA. 37+27, "PR-A"
Boring, TB-04
15.0' Lt.
STA. 37+91, "PR-A"
Boring, TB-03
17.0' Rt.
STA. 35+94, "PR-A"
Boring, TB-02
44.0' Lt.
STA. 35+43, "PR-A"
Boring, TB-01
35+00
36+00
37+00
38+00
39+00
40+00
S 87° 18' 05" E 146th St. W.B.
146th St. E.B.
146th St. W.B.
146th St. W.B.
146th St. E.B.
146th St. E.B.
Line "PR-A"
H a z e l D e ll S .B
H a ze l D e ll
N .B
H a ze l D e ll
S .B
H a ze l D e ll N .B
SOIL BORINGS
1" = 40'
1" = 40'
JPL
SH
JPL
SH
End Bents Interior Piers
Pile Size, Type, and Grade 14” x 0.312" Pipe Pile
Factored Design Load, QF (kips) 289 270
Maximum Design Soil Resistance – RR (kips) 289 270
Resistance Factor Фdyn 1 0.70 0.70
Factored Downdrag Load – DD (kips) N/A N/A
Nominal Soil Resistance – Rn (kips) 413 386
Downdrag Friction – Rsdd (kips) N/A N/A
Scour Zone Friction – Rs scour (kips) N/A N/A
Nominal Driving Resistance – Rndr (kips) 413 386
Estimated Pile Tip Elevation 735 730
Minimum Pile Tip Elevation 762 N/A
1. Testing method Based on ISS 701.05(b)
PILE LOADING FOR GEOTECHNICAL TESTING
A
T H
A N
D F
IL
E
N A
M E
M O
D E
L N
A M
E
D A
T E
P L
O T
T E
D
T
IM
E P
L O
T T
E D
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
E
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
N/A
N/A
JPL
SHSH
JPL
A
T H
A N
D F
IL
E
N A
M E
M O
D E
L N
A M
E
D A
T E
P L
O T
T E
D
T
IM
E P
L O
T T
E D
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
N/A
N/A
JPL
SHSH
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
PVI STA. 37+10.00
ELEV. = 818.00
VC = 700.0'
K = 65.26
Structure Limits 292'-6 1/2"
MSE Wall No. 1
Along Line "PR-A"
Existing Grade
Appr. (Typ.)
R.C. Bridge
Proposed Profile Grade "PR-A"
.1
.4
.6
.8
.1
.2
.9
.6
.2
.7
.2
.9
.6
.8
.9
.3
.5
.2
.6
.5
.1
.3
.8
.5
.3
.3
-5.71%5.02%
El. 808.65
Line "PR-A"
High Point Sta. 36+87.35
MSE Wall (Typ.)
Horiz. Clr. (Typ.)
10'-0" Min.
Horiz. Clr.
" Min.119'-1
Paving Exception Limits
Type 3 (Typ.)
Structural Backfill, of B Borrow w/ 525 CYS
Unclassified
Foundation, of Excavation
675.0 CYS
of B Borrow w/ 525 CYS
Unclassified
Foundation, of Excavation
675.0 CYS
Low Str. El. 800.93
(Typ.)
B-Borrow
Limits of
(Typ.)
Slope 1:1
Horiz. Clr.
" Min.119'-1
P ro p V e rt
C le a r.
/4
M in
MSE Wall No. 2
P ro p
V e rt
C le a r.
/4
M in
Type 3 (Typ.)
Structure Backfill, Limits of
Hazel Dell
Pkwy. S.B.
Hazel Dell
Pkwy. N.B.
.0
.5
.7
.7
146th St. W.B.
146th St. W.B.
146th St. E.B.
146th St. E.B.
H a ze l D e ll P k w y . N .B
H a ze l D e ll P k w y S .B
H a z e l D e ll P k w y . S .B
146th St. E.B.
146th St. W.B.
PT Sta. 35+30.43 "PR-A"
146th St. E.B.
146th St. W.B.
(Typ.)
12°30'00'' Rt.
N 89° 39' 44" E
73°55'11"
P.O.T. Sta. 19+00.00 "B"
Δ=0°24'31" Lt. (No Curve Run) P.I. Sta. 36+83.23 "A" =
S 89° 55' 45" E
77.59' Lt.
+37.76
108.89' Lt.
+65.44
141.44' Rt.
+49.90
108.36' Rt.
+27.20
105.29' Rt.
+85.11
119.57' Rt.
+36.94
102.59' Rt.
+36.04
105.04' Lt.
+04.75
85.07' Lt.
+05.77
93.61' Lt.
+66.83
113.59' Lt.
+65.77
40+00
SITUATION PLAN
PROFILE
39+0038+0037+0036+0035+0034+00
Contour Interval = 1'-0"
1" = 10'
1" = 30'
EARTHWORK SUMMARY
See Plan & Profile Sheet for Earthwork Summary Table
HYDRAULIC DATA
and no water involved Not required as bridge is over road
CAE
JPL
CAE
JPL
LAYOUT
EXISTING STRUCTURE
No Existing Structure.
UTILITIES
See Index, Sheet 2.
HAMILTON COUNTY
146TH ST. OVER HAZEL DELL PKWY.
CLEAR ROADWAY: 32'-0" E.B. AND 32'-0" W.B.
SKEW: 12°30'00" RT.
3 SPANS @ 103'-0", 85'-0", 103'-0"
CONTINUOUS COMPOSITE PRESTRESSED CONCRETE BULB-TEE BEAM
CURVE DATA
CURVE DATA
N
° 2
' 5
" W can be found in the roadway plans.
as well as additional details for drainage, guardrail, and barriers Survey control points, Right of Way limits, construction limits, see roadway plans.
For alignment references, benchmarks and additional details, All R/W labeled from Line "PR-A" unless otherwise noted.
NOTE
these to the Contractor.
updates are needed to the Contract Documents and provide in writing to the Engineer, the Engineer shall identify what If discrepancies are noted by the Contractor and communicated in the Contract Documents.
discrepancies are observed, or if no discrepancies are observed, Contractor to submit to the Engineer a memo indicating what prior to commencing the Work.
other items shown in the Kin Projects coordinate with each other Upon NTP Contractor shall confirm that controlling geometry and additional information and coordination items.
Refer to other portions of the Plans in the Kin Project for other geometry.
& Profile, etc.) for controlling alignments, profiles, sections, and Refer to the Kin Project's Roadway Plans (Typical Sections, Plan
COORDINATION WITH KIN PROJECT
MSE Wall (Typ.)
MSE Wall (Typ.)
Proposed 4'-0" Median
Line "PR-B1"
Line "B"
Line "PR-B2"
Line "A"
S.E. =N.C.
E = 2.41' L = 439.18' T = 219.62' R = 10002.00' Δ = 02° 30' 57" Lt.
P.I. = STA. 41+54.49 "PR-2"
BLOCK B
ZRP Noble West LLC
Hamilton County Noblesville Township
Sec. 15, T. 18 N., R. 4 E.
Hamilton County Noblesville Township
Sec. 16, T. 18 N., R. 4 E.
Hamilton County Clay Township
Sec. 21, T. 18 N., R. 4 E. Hamilton County Clay Township
Sec. 22, T. 18 N., R. 4 E.
S.E. =N.C.
E = 2.53' L = 389.93' T = 195.01' R = 7500.00' Δ = 02° 58' 44" Rt.
P.I. = STA. 33+35.51 "PR-A"
LOT 1
Partners Inc.
Clarian Health
LOT 64
Camille M. Moore
Michael &
LOT 63
Jack H. Ebbeler, Jr.
PARCEL 3
LLC, Et. Al.
EQ Hazel Development, PARCEL 2
Partners, LLC Plum Creek
34+00 35+00 36+00
37+00
38+00 39+00 40+00
Line "A-NER"
Line "A"
Line "A-SWR"
Line "A-NWR"
Line "A-SER"
Line "PR-2"
Sta. 38+69.24 Monument, Type D Req'd
R/W
R/ W
R/W
T em p . R /W
R /W
ESMTESMT
H az el D el l P kw y.
N .B
Skew: 12°30'00" Rt.
Line "PR-A" Sta. 37+25.28
Structure�
Line "PR-A" S 87° 18' 05" E
N
° 0
' 2
" W
N
° 3
' 0
" W
2.00' Lt.
O.P.O.T. Sta. 39+34.87 "PR-A", P.O.T. Sta. 39+34.87 "PR-2"
P.O.T. Sta. 37+52.56 "PR-A" P.O.T. Sta. 19+19.59 "PR-B2" =
P.O.T. Sta. 36+84.64 "PR-A" P.O.T. Sta. 19+30.76 "B" =
Cap (Typ.)
3'-0" Bent
Ledge (Typ.)
9" Pvm't
Cap
4'-6" Pier
Cap
4'-6" Pier
146th St. W.B.
146th St. E.B.
(Typ.)
70 LFT Pre-Compressed Foam Joint
")4
3(Exp. Length: 146'-
70 LFT Terminal Joint, Type HMA
(L a n e
(L a n e
(L a n e
(L a n e
(S h ld r.
(S h ld r.
146th St. E.B.
146th St. W.B.
146th St. W.B.
146th St. W.B.
146th St. E.B.146th St. E.B.
H a ze l D e ll S .B
H a ze l D e ll
N .B
H az el D el l S .B
H a ze l D e ll N .B
36+00 37+00 38+00 39+0035+00
PT Sta. 35+30.43 "PR-A"
M in . H or iz.
C lr.
'-0
S 87° 18' 05" E Curb Line
Curb Line
(Typ., See Note 2)
Under Bridge
Wall Light locations.)
Wall Detail Plans for detail (Typ. four slab railing. See Lighting and MSE
Expansion joint in conduit in moment
(Typ., See Note 3)
Temporary Shoring
Estimated Limits of
Coping Line (Typ.)
Modified, (Typ.)
Type PF-1
Bridge Railing, C le a r
R o a d w a y
E a s tb o u n d
C le a r
R o a d w a y
W e s tb o u n d
(Typ.)
Joint
Type IA
Structure� Line "PR-A" &
Sta. 37+25.28, Line "PR-A" Structure�
Face of Railing (Typ.)
(M e d ia n
(S h ld r.
(S h ld r.
Min. Horiz. Clr.
19'-11"
Min. Horiz. Clr.
19'-11"
Mi n.
Ho riz . C lr.
'-0
Ground Line Existing
Ground Line Proposed
Pipe Piles Footing on
Pipe Piles Footing on
(Typ.)
MSE Wall
(Typ. End Bents) Min. Pile Tip El. 762.00
Estimated Pile Tip El. 735.00 Nominal Driving Resistance.
Pile Driven to 413 Kips and 2'-0" Pile Sleeves.
14in. w/Conical Pile Tips Pile, Steel Pipe, 0.312 in.
Type PF-1 Modified Bridge Railing
146th St. Bulb-Tee Beam (Typ.)
42" x 49" Prestressed
Integral Semi Fixed Semi Fixed Integral
MSE Wall (Typ.)
SPAN A SPAN B SPAN C
PIER NO. 3PIER NO. 2BENT NO. 1
BENT NO. 4
Hazel Dell Pkwy. S.B. Hazel Dell Pkwy. N.B.
ELEVATION
(Typ. Piers) Estimated Pile Tip El. 730.00 Nominal Driving Resistance.
Pile Driven to 386 Kips 14in. w/Conical Pile Tips.
Pile, Steel Pipe, 0.312 in.
Low Str. El. 800.93
P ro p V e rt
C lr
M in
P ro p V e rt
C lr
M in
146TH STREET
HAMILTON COUNTY
INDIANA
Pile Sleeve to Grade (Typ., E.E.)
T
IM
E P
L O
T T
E D
D
A T
E P
L O
T T
E D
M
O D
E L
N A
M E
P
A T
H A
N D
F
IL
E N
A M
E
F
IL
E L
M
O D
E L N
A M
E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
IN
E
R
EERSTIGE D
PE12500107
07/22/2026
HAMILTON COUNTY
146TH ST. OVER HAZEL DELL PKWY.
CLEAR ROADWAY 32'-0" E.B. AND 32'-0" W.B.
SKEW: 12°30'00" RT.
3 SPANS: 103'-0", 85'-0", 103'-0"
CONTINUOUS COMPOSITE PRESTRESSED CONCRETE BULB-TEE BEAM
GENERAL PLAN
1" = 20'
1" = 20'
JPL
CAE
JPL
CAE
PLAN
Pier� Bent to �103'-0"
292'-6 1/2 " Out to Out Bridge Floor
Pier� Pier to �85'-0"
Pier� Pier to �103'-0"
9 1/4 "
9 1/4 "
(Typ.)
12°30'00'' Rt.
40+00
S la b
T y p
M o m e n t
30'-8" Lt.
Line "PR-A" Sta. 38+38.19 Min. Vert. Clr.
30'-8" Rt.
Line "PR-A"
Sta. 36+59.03 Min. Vert. Clr.
(T y p
Light Pole
Light Pole
P.G. El. 806.08 Sta. 38+70.78, Line "PR-A"
Bent No. 4� Brg. & �
Temp. shoring pay item on KIN Roadway Plans.
Estimated limits of temporary shoring for pier foundation construction. Included with
For Lighting Details and Locations see Roadway Plans.
See the "COORDINATION WITH ROADWAY PLANS" Note on the Layout Sheet.
NOTES:
3.
2.
1.
P.G. El. 808.65 Sta. 36+82.78, Line "PR-A"
Pier No. 2�
Bridge Appr. (Typ.)
20'-6" Min. R.C.
P.G. El. 807.77 Sta. 35+79.78, Line "PR-A"
Bent No. 1� Brg. & �
P.G. El. 808.16 Sta. 37+67.78, Line "PR-A"
Pier No. 3�
O u t to
O u t C o p in g
-5.71%5.02%
Elev. = 818.00 PVI Sta. 37+10.00
STRUCTURE TO BE BUILT ON A 700' VERTICAL CURVE
El. 779.00 of Footing Bottom
El. 779.00 of Footing Bottom
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
Drip Bead (Typ.)
Typ.
6"
2'-9"
O v e rh a n g
(Typ.)
Type PF-1, Modified
Bridge Railing, (T y p
146th St. W.B.
32'-0" Clear Roadway
70'-2" Out to Out Coping
Shoulder
6'-0"
Traffic Lane
12'-0"
1'-1"
1'-0"1"
Slope: 2%
S la b
Traffic Lane
12'-0" Shoulder 2'-0"
Median
4'-0"
Profile Grade
& Line "PR-A"
Structure� Roadway�
Traffic Lane
12'-0" Shoulder 2'-0"
146th St. E.B.
32'-0" Clear Roadway
Slope: 2%
Shoulder
6'-0"
Traffic Lane
12'-0"
1'-1"
1'-0" 1"
Type "A" (Typ.)
Constr. Joint, Seal (Typ.)
Limits of Surface face, each railing) Panel (Typ. each 1" Architectural
2'-9"8 Beam Spaces @ 8'-1" = 64'-8"
Scale: 3/8" = 1'-0"
TYPICAL SECTION
42"x49" (Typ.)
Bulb-Tee Beam BT
Prestressed Concrete
F il le t
/4
M in length of Bridge (Typ.)
conduit, runs entire 2" Galvanized Steel
(Typ., E.S.)
See Note 1
Spa. @ 40' max.
Barrier Delineator
6" Curb
GENERAL PLAN
AS NOTED
AS NOTED
JPL
EDM
JPL
EDM
GENERAL NOTES LIVE LOAD DESIGN DATA
DEAD LOAD
CONSTRUCTION LOAD
removable deck forms, and 2-ft exterior walkway.
Designed for 15 lb/ft for permanent metal stay-in-place deck forms,CONCRETE
FLOOR SLAB
DECK FALSEWORK LOADS
Grade 60 f'y = 60,000 psi
CONSTRUCTION LIVE LOAD
FINISHING-MACHINELOAD
4500 lb distributed over 10 ft. along the coping.
WIND LOAD
of the deck centered with the finishing machine.
force applied at a distance of 6 in. outside the face of coping over a 30 ft. length Designed for 20 lb/ft extending 2 ft past the edge of coping and 75 lb/ft vertical
DESIGN STRENGTHS
215 lb/ft for permanent metal deck forms.
Actual weight plus 35 lb/ft for future wearing surface and
Designed with a 7 1/2" structural depth plus 1/2" sacrificial wearing surface.
Class "C" f'c = 4,000 psi Class "B" f'c = 3,000 psi Class "A" f'c = 3,500 psi
SEISMIC DESIGN DATA
Guide LRFD 3.8.1.
Designed for 70 mph horizontal wind loading in accordance with AASHTO
Class DSeismic Soil Profile Type 0.046Acceleration Coefficient Zone 1Seismic Performance Zone
0.115SD1
Specifications, 10th Edition, 2024.
Designed for HL-93 loading in accordance with AASHTO LRFD Bridge Design against the intersection of the beam bottom flange and web.
vertical coping form. The bottom overhang brackets were assumed to be braced The top overhang brackets were assumed to be located 6 in. past the edge of the machine was assumed to be supported 6 in. outside the vertical coping form.
for support of the deck overhang past the edge of the exterior beam. The finishing the construction loads shown below. Cantilever overhang brackets were assumed The exterior beam has been checked for strength, deflection, and overturning using
See the "COORDINATION WITH KIN PROJECTS" Note on the Layout Sheet.
All reinforcing steel shall be galvanized steel.
Estimated Quantity = 9389 SFT Surface seal exposed Faces of Pier, End Bents and Concrete Barrier Railing.
other parts unless noted.
bridge deck, 3" in footings except bottom steel which shall be 4", and 2" in all Reinforcing steel covering shall be 2 1/2" Min. in top and 1" Min. in bottom of
GALVANIZED REINFORCING STEEL
HAMILTON COUNTY
146TH ST. OVER HAZEL DELL PKWY.
CLEAR ROADWAY 32'-0" E.B. AND 32'-0" W.B.
SKEW: 12°30'00" RT.
3 SPANS: 103'-0", 85'-0", 103'-0"
CONTINUOUS COMPOSITE PRESTRESSED CONCRETE BULB-TEE BEAM
CONSTRUCTION LOADING
CONSTRUCTION LOADING (cont.)
NOTES:
See Roadway plans for quantities.
be AKT Corp 567-1 White or approved equal.
anchor rods. Pay Item - Barrier Delineator shall Barrier Delineators to be mounted on the 1.
the Kin Project.
All cost of this work shall be included in the pay item for wiring provided in per INDOT Standard Specification 807.12 and all related provisions thereof.
- Grounding system shall be installed Grounding Structure and Metal Railing with this work shall be included in the pay item for steel conduit.
Specifications 805.11 and all related provisions thereof. All cost associated per INDOT Standard Drawing E 807-BLIT-03 and INDOT Standard
- These shall be installed at the locations indicated Conduit Expansion Joints
BA
A B
El. 802.52 El. 802.28
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
Beam 1Beam 2Beam 3Beam 4Beam 5Beam 6Beam 7Beam 8Beam 9
El. 802.66
El. 802.79El. 802.92El. 803.06El. 802.86El. 802.67El. 802.48
2-601
32-602 33-603
2-601
69-401
69-401
Stirrup over Each Pile) 79-401 (1 Additional
4-#7x26'-3"
4-#7x26'-3"
4-#7x26'-3"
(2 Each Face) 4-#7x30'-0"
(2 Each Face) 4-#7x30'-0"
4-#4x25'-10" 6-#7x30'-0" 6-#7x30'-0"
401 (Typ. - Step)
2'-0"
(Measured along � of Bent)
9 Spa. @ 7'-6" = 67'-6" (Pile Spacing)
2'-0"
"2 19 "2
(Typ.)
6 Spa. @ 12" Max. = 5'-11"
ELEVATION
"2 19"2
(602, 603 & 401 Spa.)
PLAN - BENT NO. 1
71'-6"
� Bent, � Brg. & � Piles
Step Spacing
Beam Spacing
� Beam (Typ.)
Profile Grade& Line "PR-A"
"4 38'-0"2
18'-3"2 18'-3"2
18'-3"2 18'-3"2
18'-3"2 18'-3"2
18'-3"4 35'-4
Line "PR-A" Sta. 35+79.78
Bent No. 1�
35'-9"35'-9"
12°30'0" Rt.
"8 52'-7"4
3"± = 66'-28 38 Spa. @ 8'-3"8
52'-7
8'-1" (Typ.
S
° 1
' 0
" E
12°30'0" (Typ.)
2-601 2-601
48 - 401 Spa. w/ 602 & 603 = 49'-0" (In Step)
(Step) 4 Lines of 2-#4x25'-10"
All reinforcing bars to be galvanized.
For Galvanized Bar Bending Details, follow CRSI Manual of Standard Practice.
For Section A-A and B-B, Bar Bending Diagrams and Bill of Materials, see Sheet 11.
Min. Lap Length: #7 = 3'-9"; #4 = 2'-2"
See the "COORDINATION WITH ROADWAY PLANS" Note on the Layout Sheet.
NOTES:
1.
2.
3.
4.
5.
Tip (Typ.)
Pile w/Conical Pile (2 Each Face)
4-#7x18'-9"
6-#7x18'-9"
602, 603 & 401
El. 798.78 El. 799.02
4-#4x25'-10"
Scale: 3/8"=1'-0"
Scale: 3/8"=1'-0"
Ea. Pile) (10 Total) 1-402 (1 Req'd
Pile Sleeve (Typ.)
T
IM
E P
L O
T T
E D
D
A T
E P
L O
T T
E D
M
O D
E L
N A
M E
P
A T
H A
N D
F
IL
E N
A M
E
F
IL
E L
M
O D
E L N
A M
E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
IN
E
R
EERSTIGE D
END BENT NO.1 DETAILS
3/8" = 1'-0"
3/8" = 1'-0"
DOR
UL
DOR
UL
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
BA
A B
El. 800.91
El. 800.51
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
Beam 9Beam 8Beam 7Beam 6Beam 5Beam 4Beam 3Beam 2Beam 1
El. 801.03
El. 801.14El. 801.25El. 801.37El. 801.15El. 800.94El. 800.73
2-601
32-602 33-603
69-401
69-401
Stirrup over Each Pile) 79-401 (1 Additional
4-#7x26'-3"
4-#7x26'-3"
4-#7x26'-3"
(2 Each Face) 4-#7x30'-0"
(2 Each Face) 4-#7x30'-0"
4-#4x25'-10" 6-#7x30'-0" 6-#7x30'-0"
401 (Typ. - Step)
ELEVATION
(602, 603 & 401 Spa.)
PLAN - BENT NO. 4
� Bent, � Brg. & � Piles
Step Spacing
Beam Spacing
� Beam (Typ.)
Profile Grade& Line "PR-A"
Line "PR-A" Sta. 38+70.78
Bent No. 4�
12°30'0" Rt.
S
° 1
' 0
" E
12°30'0" (Typ.)
2-601 2-601
(Step) 4 Lines of 2-#4x25'-10"
All reinforcing bars to be galvanized.
For Galvanized Bar Bending Details, follow CRSI Manual of Standard Practice.
For Section A-A and B-B, Bar Bending Diagrams and Bill of Materials, see Sheet 11.
Min. Lap Length: #7 = 3'-9"; #4 = 2'-2"
See the "COORDINATION WITH ROADWAY PLANS" Note on the Layout Sheet.
NOTES:
1.
2.
3.
4.
5.
Tip (Typ.)
Pile w/Conical Pile (2 Each Face)
4-#7x18'-9"
6-#7x18'-9"
El. 797.01 El. 797.41
4-#4x25'-10"
Scale: 3/8"=1'-0"
Scale: 3/8"=1'-0"
71'-6"
35'-9"35'-9"
"8 52'-7"4
3"± = 66'-28 38 Spa. @ 8'-3"8
52'-7
"4 38'-0"2
18'-3"2 18'-3"2
18'-3"2 18'-3"2
18'-3"2 18'-3"2
18'-3"4 35'-4
(Typ
8'-1"
48 - 401 Spa. w/ 602 & 603 = 49'-0" (In Step)
602, 603 & 401
2-601
"2 19 "2
(Typ.)
6 Spa. @ 12" Max. = 5'-11"
"2 19 "2
2'-0"
(Measured along � of Bent)
9 Spa. @ 7'-6" = 67'-6" (Pile Spacing) 2'-0"
Ea. Pile) (10 Total) 1-402 (1 Req'd
Pile Sleeve (Typ.)
END BENT NO. 4 DETAILS
3/8" = 1'-0"
3/8" = 1'-0"
DOR
UL
L im it s o f S u rf a c e S e a l
SECTION A-A SECTION B-B
Coping
Concrete
Precast
2'-8"
2'-8"2'-8"
1'-0"
401 x 4'-0"
Front Face MSE Wall Front Face MSE Wall
603 x 15'-2"602 x 13'-1"
1'-6"
3'-0"
1'-6"
(E m b e d
P il e
V a ri e s
S te p
/1
(Typ.)
2" Cl.
Coping
Concrete
Precast
Bearing Assembly
4 3/8"
5 Eq. Spa. (#7 Top)
3 Eq. Spa. (#4 Step) 4 3/8"
2'-0" Ø Pile Sleeve (Typ.)
Constr. Joint
Pile w/Conical Pile Tip existing grade(Typ.)
installed to top of
2'-0" Ø Pile Sleeve
Pile w/Conical Pile Tip
(E m b e d
P il e
1'-6"
3'-0"
1'-6"
4 - #7
2 - #7
2 - #7
6 - #7 6 - #7
2 - #7
2 - #7
4 - #7
#4 (Step -Typ.) #4 (Step -Typ.)
401 (Step) 401 (Step)
V a ri e s
S te p
/1
S p a
M a x
M in
(Typ.)
2" Cl.
Joint Filler
Performed Expansion
Joint Filler
Performed Expansion
4'-8"Min. Min. 4'-8"
2'-9"
601 x 15'-3"
129 SFTSURFACE SEAL
10 EACHPILE SLEEVE
10 EACHCONICAL PILE TIP, 14 IN.
BENT 1 = 9 @ 66 LFT / BENT 4 = 9 @ 65 LFT
594 / 585 LFT
PILE, STEEL PIPE, 0.312 IN., 14 IN.
1 EACHTEST PILE, DYNAMIC, RESTRIKE
76 / 75 LFTTEST PILE, DYNAMIC, PRODUCTION
1 EACHDYNAMIC PILE LOAD TEST
MISCELLANEOUS
30.1 CYSCONCRETE, C, SUBSTRUCTURE
CONCRETE
5036TOTAL REINFORCING BARS
1310TOTAL #4
25'-10"8#4
69'-6"10402
4'-0"265401
1472TOTAL #6
15'-2"33603
13'-1"32602
15'-3"4601
2254TOTAL #7
26'-3"12#7
18'-9"10#7
30'-0"20#7
WEIGHT (LBS.)LENGTHNO. OF BARSSIZE & MARK
GALVANIZED REINFORCING BARS
END BENT NO. 1 OR NO. 4
BILL OF MATERIALS
All reinforcing bars to be galvanized.
For Galvanized Bar Bending Details, follow CRSI Manual of Standard Practice.
NOTES:
1.
2.
* QUANTITIES FOR 1-END BENT, 2-REQUIRED
402 402
*402 x 69'-6"
Provide 1 1/2 extra turns at top and bottom of spirals and 1 1/2 turn laps between individual spirals.
"2
1'-10
L im it s o f S u rf a c e S e a l
T
IM
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
END BENT DETAILS
3/4"=1'-0"
3/4"=1'-0"
DOR
UL
DOR
UL
S p a
M a x
M in
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
B e a m
2" Open Joint Open Joint2" 23'-6"23'-6" 23'-6"
"4 3"± = 66'-28
38 Spa. @ 8'-3"8 52'-3 "8
52'-3
7'-9" 8'-0" 7'-9" 8'-9" 6'-0" 8'-9" 7'-9" 8'-0" 7'-9"
� Brg.
� Pier
� Brg.
Construction Joint (Typ.)
Keyway1'-0"x3'-0"x3"
S
° 1
' 0
" E
Line "PR-A" Pier�
12°30'0" Rt.
(Typ.)
3'-0"
Profile Grade& Line "PR-A"
(Typ.
8'-1"
Step Spacing
Beam Spacing
Dim. C, Level (Typ.)
Dim. D
Dim. C, Level
Dim. E Dim. F Dim. G Dim. H Dim. I Dim. J Dim. K
Dim. L
(T y p
(Typ.)
R 5'-9"
PIERS 2 & 3 - CAP PLAN
Dim. B, Level
Dim. A, Level
El. 786± Proposed Ground
PIERS 2 & 3 - ELEVATION
Tip (Typ.)
Pile w/Conical Pile
5'-9" (Typ.)
(T y p
All reinforcing bars to be galvanized.
For Galvanized Bar Bending Details, follow CRSI Manual of Standard Practice.
For Bar Bending Diagrams, see Sheet 14.
For additional pier details, see Sheets 13-15.
See the "COORDINATION WITH ROADWAY PLANS" Note on the Layout Sheet.
NOTES:
1.
2.
3.
4.
5.
Joint, Type 1A (Typ.)
Optional Construction
2'-6" 2'-6"
@ 6" = 5'-6" (Typ.)
12 Sets of 2 - 631 1'-0" 1'-0"
@ 6" = 5'-6" (Typ.)
12 Sets of 2 - 631
(Place in Footing) (Typ.)
13 - 831 Ea. Face & 1 in Ea. Nose (28 Total)
3 - 832 (In Nose) (Typ.)
(Bundled) (Typ.)
5 Lines of 1 - 934 & 1 -935
4 - #9 x 23'-0" (Typ.)
#5 x 11'-10" Ea. Face (2 Total) (Typ.)
#8 x 6'-0" Ea. Face (Typ.)
#8 x 4'-10" Ea. Face (Typ.)
#8 x 4'-2" Ea. Face (Typ.)
#8 x 3'-8" Ea. Face (Typ.)
#8 x 3'-4" Ea. Face (Typ.)
3 - #8 x 3'-4" (In Nose) (Typ.)
#5 x 12'-8" Ea. Face (2 Total) (Typ.)
#5 x 13'-10" Ea. Face (2 Total) (Typ.)
#5 x 15'-9" Ea. Face (2 Total) (Typ.)
#5 x 19'-0" Ea. Face (2 Total) (Typ.)
Ea. Face (22 Total) (Typ.)
(Typ.)
6 Even Spa. = 5'-9"3" (Typ.)
12'-0" (Typ.)
24 Lines of 1 - 932 & 933
10 Lines of 1 - 932 & 933
#5 x 23'-0" Ea. Face (2 Total) (Typ.)
11 - #5 x 11'-6"
3"3"
58 - 633 Spa. w/ 631 & 632
33 - 633 Spa. w/ 631 & 632
33 - 633 Spa. w/ 631 & 632
Dim. C, Level
(Typ.)
11 Sets of 632 @ 1'-0" = 10'-0"
Ahead as Shown) (94 Total) (Typ.)
Spa. @ 2'-0" Max. (Stagger Location Alternate 6 & 5 - 331 Per Row
(34 Total) (Typ.)
Spa. w/ #5
17 - 531 Ea. Face
PIER DETAILS
3/8"=1'-0"
UL
EDM
MAR
UL
802.86803.01803.15803.29803.43803.24803.06802.88802.68799.18783.50779.00PIER 3
803.27803.44803.60803.77803.93803.77803.61803.45803.28799.77783.50779.00PIER 2
LKJIHGFEDCBADIM.
TABLE OF ELEVATIONS
3/8"=1'-0"
(Lapped w/ 831) (Typ.)
13 - #8 x 18'-9" Ea. Face & 1 in Ea. Nose (28 Total)
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
� Pier
PIERS 2 & 3 - STEM BASE
Line "PR-A" Pier�
S
° 1
' 0
" E
12°30'0" Rt.
Profile Grade& Line "PR-A"
12'-0"11'-8"12'-0"11'-8"12'-0"
(Below Optional Construction Joint)
PIERS 2 & 3 - FOOTING PLAN
2'-2"8 Spaces @ 7'-6" = 60'-0"2'-2"
All reinforcing bars to be galvanized.
For Galvanized Bar Bending Details, follow CRSI Manual of Standard Practice.
For Bar Bending Diagrams, see Sheet 14.
For additional pier details, see Sheets 12, 14, & 15.
NOTES:
1.
2.
3.
4.
Sta. 37+67.78, Line "PR-A" Pier No. 3�
Sta. 36+82.78, Line "PR-A" Pier No. 2�
Profile Grade& Line "PR-A"
5'-11"52'-6"7 Spaces @ 7'-6" = 5'-11"
#5 (Typ.)
#8 (Typ.) 331 (Typ.)
(Typ.)
531 (Ea. Face)
/2
/2
B o t.
L o n g
/2
T o p L o n g
E v e n S p a
/2
Footing� Pier & �(Stagger Laps) 10 - Lines of 932 & 933 (Bot.)
24 - Lines of 932 & 933 (Top)
(Bottom Reinforcement Shown)
3 1/2" 1'-0" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9"
= 2'-0"
@ 12" 1'-9" 1'-0" 3 1/2" Bot. Transverse
3 1/2" 42 Even Spa. = 63'-9" Top Transverse3 1/2"
(Typ.)
1 - 931 (Bot.) (52 Total) 1 - 931 (Top) (43 Total)
(Typ. Ea. Face) 1" Architectural Formliner
Ahead
64'-4"
Ahead
S p a
S p a
2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa. 2 Spa.
5'-0" Min. Lap
3/8"=1'-0"
UL
EDM
MAR
3/8"=1'-0"
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
2'-0"4'-6"4'-6"2'-0"
M in
2'-3"2'-3"
4'-6"
� Pier
E m b e d m e n t
M in
13'-0"
PIERS 2 & 3 -SECTION
Scale: 3/8"=1'-0"
S te p s V a ri e s
Joint, Type 1A (Typ.)
Optional Construction
932 & 933 Lines of
Spa. Horiz. w/ #5 Spa. Vert. w/ #8 531 (Typ.)
#5
#8 (Lapped w/ 831)
934 (Top, Bundled w/ 935)
#9 (Bot.)
C lr
3" Clr. (Typ.)
C lr
(Typ. Ea. Face) 1" Architectural Formliner
3" Clr.
9" (Typ.)
3'-0" (Stem)
5'-0" (Typ.)
S p a
M a x
935 (Top, Bundled w/ 934)
M in
L a p
12'-6"
931 x 15'-8"
38'-5"
932 x 40'-0"
30'-5"
933 x 32'-0"
1'-4"
831 x 8'-11"
531 x 5'-10"
2'-6" 331 x 3'-5"
9' -3
6"
3"
934 x 25'-6"
135° Hook 90° Hooks
23'-0"
3'-1"
631 x 14'-2"
832 x 13'-2"
4'-0"
632 x 16'-0"
633 x 6'-0"
4'-0"
935 x 23'-6"
90° Hooks
21'-0"
BUNDLING DETAIL
Wire Ties
Bundled vertically 934 and 935 Bars shall be
No Scale
AS NOTED
UL
EDM
MAR
UL
AS NOTED
BAR BENDING DETAILS
No Scale
For additional pier details, see Sheets 12, 13, & 15.
Manual of Standard Practice.
For Galvanized Bar Bending Details, follow CRSI
All reinforcing bars to be galvanized.
NOTES:
3.
2.
1.
BILL OF MATERIALS
PIER NO. 2
GALVANIZED REINFORCING BARS
SIZE & MARK NO. OF BARS LENGTH WEIGHT (LBS.)
931 95 15'-8"
932 34 40'-0"
933 34 32'-0"
934 15 25'-6"
935 15 23'-6"
#9 12 23'-0"
TOTAL #9 16821
831 84 8'-11"
832 18 13'-2"
#8 30 3'-4"
#8 12 3'-8"
#8 12 4'-2"
#8 12 4'-10"
#8 12 6'-0"
#8 84 18'-9"
TOTAL #8 7703
631 144 14'-2"
632 33 16'-0"
633 124 6'-0"
TOTAL #6 4975
531 102 5'-10"
#5 66 11'-6"
#5 6 11'-10"
#5 6 12'-8"
#5 6 13'-10"
#5 6 15'-9"
#5 6 19'-0"
#5 6 23'-0"
TOTAL #5 2014
331 282 3'-5"
TOTAL #3 362
TOTAL REINFORCING BARS 31875
CONCRETE
CONCRETE, A, SUBSTRUCTURE 118.6 CYS
CONCRETE, B, FOOTINGS 139.4 CYS
MISCELLANEOUS
DYNAMIC PILE LOAD TEST 1 EACH
TEST PILE, DYNAMIC, PRODUCTION 61 LFT
TEST PILE, DYNAMIC, RESTRIKE 1 EACH
PILE, STEEL PIPE, 0.312 IN., 14 IN.
1275 LFT
25 @ 51 LFT
CONICAL PILE TIP, 14 IN. 26 EACH
B BORROW 525 CYS
EXCAVATION, FOUNDATION, UNCLASSIFIED 675.0 CYS
SEAL COAT GRAFFITI RESISTANT 2028 SFT
SURFACE SEAL 1453 SFT
MODIFIED STAIN AND SEALER 575 SFT
BILL OF MATERIALS
PIER NO. 3
GALVANIZED REINFORCING BARS
SIZE & MARK NO. OF BARS LENGTH WEIGHT (LBS.)
931 95 15'-8"
932 34 40'-0"
933 34 32'-0"
934 15 25'-6"
935 15 23'-6"
#9 12 23'-0"
TOTAL #9 16821
831 84 8'-11"
832 18 13'-2"
#8 30 3'-4"
#8 12 3'-8"
#8 12 4'-2"
#8 12 4'-10"
#8 12 6'-0"
#8 84 18'-9"
TOTAL #8 7703
631 144 14'-2"
632 33 16'-0"
633 124 6'-0"
TOTAL #6 4975
531 102 5'-10"
#5 66 11'-6"
#5 6 11'-10"
#5 6 12'-8"
#5 6 13'-10"
#5 6 15'-9"
#5 6 19'-0"
#5 6 23'-0"
TOTAL #5 2014
331 282 3'-5"
TOTAL #3 362
TOTAL REINFORCING BARS 31875
CONCRETE
CONCRETE, A, SUBSTRUCTURE 116.8 CYS
CONCRETE, B, FOOTINGS 139.4 CYS
MISCELLANEOUS
DYNAMIC PILE LOAD TEST 1 EACH
TEST PILE, DYNAMIC, PRODUCTION 61 LFT
TEST PILE, DYNAMIC, RESTRIKE 1 EACH
PILE, STEEL PIPE, 0.312 IN., 14 IN.
1275 LFT
25 @ 51 LFT
CONICAL PILE TIP, 14 IN. 26 EACH
B BORROW 525 CYS
EXCAVATION, FOUNDATION, UNCLASSIFIED 675.0 CYS
SEAL COAT GRAFFITI RESISTANT 1981 SFT
SURFACE SEAL 1400 SFT
MODIFIED STAIN AND SEALER 581 SFT
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
23'-6" 23'-6" 23'-6"
Formliner (Typ. All Pier Stems)
V-Notches and Texture
Proposed Ground El. 786 ±
Proposed Ground El. 786 ±
Stem End Faces (Typ.)
Texture Formliner Only on
'-0
'-5
1'-11"2'-8" 1'-7" 2'-11" 3'-5" 2'-0" 2'-3" 3'-7" 3'-1"
3'-3"1'-5"
1'-1"
3'-10"2'-6"1'-11"2'-7"
1'-1"
3'-5"2'-4" 1'-11"1'-10"3'-3" 2'-3"2'-3"2'-10"1'-8"
1'-1"
3'-9"2'-0"
9"
4'-0" 3'-5"4'-1" 3'-8"
1'-0"
5'-8"
10" 11"
1'-8" 2'-1"3'-0"2'-4"2'-3" 1'-5"2'-4"2'-11"2'-11"2'-6" 2'-5" 10"
1'-0"
2'-2"3'-7"
1'-1"8"
'-3
10"
(T y p
M in
M in
1"1"
PIERS 2 & 3 - V-NOTCH REVEAL DETAIL
Face
Pier Concrete
� V-Notch
AESTHETIC PIER DETAILS
3/8"=1'-0"
JPL
AEH
JPL
ARM
3/8"=1'-0"
PIERS 2 & 3 - ARCHITECTURAL ELEVATION VIEW
NOTES:
For Additional Pier Details, See Sheets 12-14.3.
Mirror the Design About the Centerline of Piers 2 and 3 for the Opposing Faces.2.
Use this Layout for V-Notch and Formliner Application as Identified in the Special Provisions.1.
Concrete Stain and Sealer Without Formliner
LEGEND:
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
Beam No. 1A
Beam No. 2A
Beam No. 3A
Beam No. 4A
Beam No. 5A
Beam No. 6A
Beam No. 7A
Beam No. 8A
Beam No. 9A
S p a
"A"
See Detail
See Detail "B"
Brg.� Bent No. 1 & � Diaphragm� Brg.� Brg.�
Diaphragm� Diaphragm� Brg.� Bent No. 4 & � Brg.� Brg.�
Beam No. 1B
Beam No. 2B
Beam No. 3B
Beam No. 4B
Beam No. 5B
Beam No. 6B
Beam No. 7B
Beam No. 8B
Beam No. 9B
Beam No. 1C
Beam No. 2C
Beam No. 3C
Beam No. 4C
Beam No. 5C
Beam No. 6C
Beam No. 7C
Beam No. 8C
Beam No. 9C
MC18x42.7 (Typ.)
"2 151'-0
11"
11"
"2 151'-0 41'-7" 41'-7" "2
151'-0 "2 151'-0
� Brg. Brg. to �102'-1" � Brg. Brg. to �83'-2" � Brg. Brg. to �102'-1"
� Pier Span A Bent to �103'-0" � Pier Span B Pier to �85'-0" � Pier Span C Bent to �103'-0"
Structure �Line "PR-A" &
11"
11"
Brg.� Brg.�
Pier No. 2� Pier No. 3�
Sta. 38+70.78, Line "PR-A" Brg. & Bent No. 4�Sta. 37+67.78, Line "PR-A"
S 87° 18' 05" E
Sta. 36+82.78, Line "PR-A" Sta. 35+79.78, Line "PR-A"
Brg. & Bent No. 1�
Brg.� Bent & �
Ledge
Pvm't.
9"
4"
12°30'0"
3'-0" Cap
Bulb-Tee Beam (Typ.)
42" x 49" Prestressed Concrete
Top Flange
Bottom Flange
Bulb-Tee Beam (Typ.)
42" x 49" Prestressed Concrete
Top Flange
Web
Beam�
4" Min.
8"
8"
6"
12°30'00"
Skew
Right
Skew
Right
Pad TH1 (Typ.)
Elastomeric Bearing
Pier�
Brg.�
2'-3"
2'-3"
4'-6" Cap
Bottom Flange
1'-6" 1'-6"
Beam�
Back Face of Bent
Bearing Assembly and Hatch
Web
"4
"4
FRAMING PLAN
AS NOTED
AS NOTED
DDM
SH
DOR
EDM
FRAMING PLAN
Scale: 3/32" = 1'-0"
DETAIL "A"
Scale: 1/2" = 1'-0"
DETAIL "B"
Scale: 1/2" = 1'-0"
NOTES
Note on the Layout Sheet.
See the "COORDINATION WITH ROADWAY PLANS"3.
For Intermediate Diaphragm Details see Sheet 28.2.
For Bearing Details see Sheets 20 & 21.1.
/4
M in
Top of Slab
Bottom of Slab
Bottom of Fillet
Top of Beam
Bottom of Beam
/4
M in
T
IM
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
1'-5 1/2" 8"
4'-1"
/2
3" 3"
(Typ.)
3/4" Chamfer
1'-5 1/2"
4'-1"
1'-5 1/2" 3" 8" 3"
/2
16 Spaces @ 2" = 2'-8"
3'-4"
16 Spaces @ 2" = 2'-8"
3'-4" (Typ.)
3/4" Chamfer
1'-5 1/2"
/2
/2
"2
"2
"2
"2
"2
"2 "2
"2
Beam� Beam�
1'-5 1/2"3"8"3"1'-5 1/2"
4'-1"
/2
(Typ.)
3/4" Chamfer
/2
16 Spaces @ 2" = 2'-8"
3'-4"
"1'-5 1/2"3"8"3"1'-5 1/2"
4'-1"
/2
(Typ.)
3/4" Chamfer
/2
16 Spaces @ 2" = 2'-8"
3'-4"
"2
"2
"2
"2
"2
"2 "2
"2
Beam� Beam�
1'- 4"
/2
3'-1 1/2"
1'- 4"
126°
5 1/2"
/2
1/2" Ø4
6" Hook
4 1/2"
3 1/2" Ø
12" Ø
1/2" Ø4
/2
5 1/2"
6" Hook
4'-1"
1'-5 1/2"8"1'-5 1/2"3" 3"
1 1/4" Cl.
3'-4"
412 (Typ.)
411 and 501
#4 x 3'-10"1 1/2" Cl.
1 1/4" Cl.
1 1/4" Cl.
Beam�
(Typ.)
#6 Full Length
1 1/4" Cl.
8"
/4
End Bent Diaphragms Holes in all beams for for Pier Diaphragms, 1" Ø 1" Ø Holes in Interior Beam
/2
/2
/4
TYPICAL REINFORCING
Scale: 1" = 1'-0"
SECTION @ BEAM END SPANS A & C
Scale: 1" = 1'-0"
SECTION @ MIDSPAN SPAN A & C
Scale: 1" = 1'-0"
301 x 6'-5"
302 x 2'-8"
411 x 8'-9"
412 x 12'-3"
END VIEW SIDE VIEW
SECTION @ BEAM END SPAN B
Scale: 1" = 1'-0"
SECTION @ MIDSPAN SPAN B
Scale: 1" = 1'-0"
LEGEND
Debond 8'-0" from end of beam Debond 5'-0" from end of beam
BEAM DETAILS
AS NOTED
AS NOTED
DOR
EDM
DOR
EDM
FILLET DETAIL
Scale: 1/2" = 1'-0"
2 3/8"2 1/2"2 1/2"2 5/8"Residual Camber
-1"-7/8"-2 3/8"-2 1/4"Dead Load Deflection
3 3/8"3 3/8"4 7/8"4 7/8"Initial Camber
B Int. BeamB Ext. BeamA & C Int. BeamA & C Ext. BeamSpan
BEAM CAMBER @ MIDSPAN (in.)
BEAM GENERAL NOTES
and Span 2 has an elastic shortening of 0.666".
grade by the fabricator. Spans 1 & 3 have an elastic shortening of 0.848" Allowance should be made in beam length for elastic shortening and finishing machine, forms, etc.
beam, from construction loads such as the weight of the concrete deck, be provided to prevent the rotation of the beams, particularly the exterior Beams shall be maintained vertically at all times. Suitable restraint shall times during storage, transportation and lifting to resist lateral loads.
transporting to the job site. Adequate bracing must be provided at all Beams shall be supported at bearing points while stored and while tool (Maximum depth of scoring should be 1/4").
Top of beams to be scored transversely at about 3" centers with a pointed
Beams shall be cast a minimum of 28 days before the deck is poured.
5.
4.
3.
2.
1.
dead load of the beam.
forces at the time of erection minus the downward deflection from the Anticipated beam camber is the upward deflection from pre-stressing shall notify the Engineer immediately so that adjustments can be made.
If the actual camber as erected is different by 1" or more, the Contractor The camber values as shown in the above table are expected values.
NOTES:
Standard Practice.
For Galvanized Bar Bending Details, follow CRSI Manual of
For Reinforcing Bar Notes, see Standard Drawing E 703-BRST-01.
Drawings E 707-BPBF-01 through -04.
For Fabrication Tolerances of Prestressed Beams, see Standard
All reinforcing steel extended into the deck shall be galvanized.
deck slab.
top of the beam at a minimum of 3/4" below the bottom of the dead load deflection of the deck slab (residual camber) with the Bridge seat elevations were calculated using design camber and shop.
Sealer on the tops of the beams shall be done by fabricators
11.
10.
9.
8.
7.
6.
501 x 8'-9"
END VIEW SIDE VIEW
in place of Holes through the Beam.
of Exterior Beams at the Pier Diaphragms Threaded Insert shall be used on Inside1.
NOTES:
(Spaced w/Stirrups)
#4 x 3'-10"
4-#6
(2 Ea. Fa.)
8 - #6 x 2'-4"
301 & 302
4"
16 Spa. @ 6" = 8'-0" (301 and 302)
2"
1'-10" without the use of Heat.
1'-10" Projection and Shop Bend
Cut 7 Strands in Bottom Row with
501 (1 Ea. Fa.)
Bundled with
2 - #6 x 3'-3"
7"
9"
(501)
26 Spa. @ 3" = 6'-3" (Spans A & C) (Spans A & C) 14 Spa. @ 6" = 6'-6"
(501)
(Spaced w/Stirrups)
#4 x 3'-10"
4-#6
(2 Ea. Fa.)
8 - #6 x 3'-3"
301 & 302
4"
16 Spa. @ 6" = 8'-0" (301 and 302) 1'-10"
(501) without the use of Heat.
1'-10" Projection and Shop Bend
Cut 7 Strands in Bottom Row with
501 (1 Ea. Fa.)
Bundled with
2 - #6 x 3'-3"
(Spans A, B, & C) 14 Spa. @ 6" = 6'-6"
(501)
26 Spa. @ 3" = 6'-3" (Spans A, B, & C) 9"
3"
3"
T
IM
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
51'-9" 51'-9"
Top Flange
Bottom Flange
Web
Beam� or Bent No. 4 Brg. Bent No. 1� or Pier No. 3 Brg. Pier No. 2�
Beam� or Bent No. 4 Brg. Bent No. 1� or Pier No. 3 Brg. Pier No. 2�
Beam�
11 - Draped Strands
37 - Straight Strands
2 - Straight Strands 4 - #6 Full Length
14 - 501 Spa. @ 6" = 6'-6" 6"
102 - 411 Spa. @ 9" Max.=75'-6" 6"
14 - 501 Spa. @ 6" = 6'-6"
9 7/8"9 7/8"
/4
/4
9" 8"
10" @ Piers
26 - 501 Spa. @ 3" = 6'-3"
41'-4 4/5" 20'-8 2/5" 41'-4 4/5"
103'-6"
9" 26 - 501 Spa. @ 3" = 6'-3"
1'-0" @ Bents
1" Ø Hole (Typ. Ea. End)
(Typ. Ea. End) 2 - 412 x 12'-3" to Beam End) Holes for Diaphragm�( in Interior Beams for Interior Steel Diaphragms Exterior Beams or 1" Ø Plastic Pipe or Equivalent
7/8" Ø Threaded Inserts on Exterior Face of
9"
@ Bents Notch in Beam
9" 8"
Details @ Piers See Bearing Assembly
Details @ Bents See Bearing Assembly
BEAM PLAN (SPANS A & C)
Vertical Scale: 1/2" = 1'-0" Horizontal Scale: 1/4" = 1'-0"
BEAM ELEVATION (SPANS A & C)
Vertical Scale: 1" = 1'-0" Horizontal Scale: 1/4" = 1'-0"
BEAM DESIGN DATA
9. For additional Beam Details, see Sheet 17.
8. For Intermediate Diaphragm details, see Sheet 28.
details, see Sheets 20 & 21.
7. For Elastomeric bearing details or bearing plate assembly
6. Reinforcing steel, fy = 60 ksi
5. Concrete strength at 28 days, f'c = 8.0 ksi
4. Concrete strength at release, f'ci = 6.0 ksi
3. Hold down force 26.27 kips
2. Initial pull per strand 43,900 lb of 270 ksi (Area = 0.271 sq. in.)
seven-wire strands with an ultimate tensile strength
1. Prestressed strands shall be 0.6" Ø uncoated, low-relaxation, BEAM END DETAIL @ BENT
Scale: 1" = 1'-0"
AS NOTED
AS NOTED
DOR
EDM
DOR
EDM
BEAM END DETAIL @ PIER
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
84'-6"
42'-3" 42'-3"
33'-9 3/5"16'-10 4/5"33'-9 3/5"
8"8"
Brg. Pier No. 2� � Brg. Pier No. 3
� Beam
Bottom Flange
Top Flange
Web
� Beam
� Brg. Pier No. 2
� Beam
� Brg. Pier No. 3
31 - Straight Strands
11 - Draped Strands
2 - Straight Strands 4 - #6 Full Length
(Typ. Ea. End) 2 - 412 x 12'-3"
46 - 411 Spa. @ 9" Max.=56'-6" 6"
14 - 501 Spa. @ 6" = 6'-6"
84'-6"
14 - 501 Spa. @ 6" = 6'-6" 6"
8"
10" @ Piers
8"
9 7/8"9 7/8"
/4
/4
9" 26 - 501 Spa. @ 3" = 6'-3" 26 - 501 Spa. @ 3" = 6'-3"
9"
1" Ø Hole in Interior Beams for Interior Steel Diaphragms Exterior Beams or 1" Ø Plastic Pipe or Equivalent
7/8" Ø Threaded Inserts on Exterior Face of to Beam End) Holes for Diaphragm�( to Beam End) Holes for Diaphragm�(
10" @ Piers
1" Ø Hole
Details @ Piers (Typ.)
See Bearing Assembly
BEAM PLAN (SPAN B)
Vertical Scale: 1/2" = 1'-0" Horizontal Scale: 1/4" = 1'-0"
BEAM ELEVATION (SPAN B)
Vertical Scale: 1" = 1'-0" Horizontal Scale: 1/4" = 1'-0"
BEAM DESIGN DATA
For additional reinforcing at beam ends see Sheet 18.10.
For additional Beam Details, see Sheet 17.9.
For Intermediate Diaphragm details, see Sheet 28.8.
details, see sheets 20 & 21.
For Elastomeric bearing details or bearing plate assembly7.
Reinforcing steel, fy = 60 ksi6.
Concrete strength at 28 days, f'c = 8.0 ksi5.
Concrete strength at release, f'ci = 6.0 ksi4.
Hold down force 32.18 kips3.
Initial pull per strand 43,900 lb2.
of 270 ksi (Area = 0.271 sq. in.)
seven-wire strands with an ultimate tensile strength Prestressed strands shall be 0.6" Ø uncoated, low-relaxation, 1.
AS NOTED
AS NOTED
DOR
EDM
EDM
Scale: 1"=1'-0"
7"1'-1"1'-1"7"
"4
6 2'-2" "4
EMBEDDED BEARING PLATE DETAILS @ PIER
PLAN VIEW
Beam� Concrete Bulb-Tee Beam 42"x49" Prestressed
END VIEW
�1/2" x 3'-2 1/2" x 1'-4" Embedded
1'-0"
6"6"
Bearing�
Beam�
PLAN
ELASTOMERIC BEARING PAD
PIER NO. 2 & NO. 3
SECTION
Scale: 3" = 1'-0"
12 Gage Stainless coils Thickness = 0.1046 in. or
6 - Metallic Bonded Shims, (Typ. All Sides)
1/8" Min.
(T y p
/2
In t.
L a y e r
(T y p
/3
E x t.
L a y e r draft all sides
Scale: 1" = 1'-0"
END VIEW
SIDE VIEW @ PIER
BEARING ASSEMBLY @ PIER
Beam�
Bearing�
1"
�Taper Vulcanized to the All bearings shall be detail�
See embedded
1"
See Table for Dimensions Taper Plate (As Required)
Steel load Plate or
� or Taper �Load Vulcanized to the Steel
All bearings shall be detail� See embedded
Type TH-1 Elastomeric Bearing Pad
6"6"
5/16"
5/16"
"c""b"LOCATION "a"
Pier 2, Span A
DIMENSIONS
TAPER PLATE DIMENSIONS
"d"
All
Beam No.
"a
"b
"c
"d"
B a c k
S ta ti o n
F o rw a rd
S ta ti o n
SIDE VIEW PLAN
Scale: 1" = 1'-0"
TAPERED PLATE DETAILS
1'-2"1"
1"
3'-6"
1'-2"1"
1 1/4" 1"
1 1/8" 1"
1"
1'-2"
1'-2"
3'-6"
3'-6"
3'-6"
Pier 2, Span B
Pier 3, Span B
Pier 3, Span C
2" 2"
T
IM
E P
L O
T T
E D
D
A T
E P
L O
T T
E D
M
O D
E L
N A
M E
P
A T
H A
N D
F
IL
E N
A M
E
F
IL
E L
M
O D
E L N
A M
E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
IN
E
R
EERSTIGE D
PE12500107
07/22/2026
NOTES
6. Embedded Bearing Plates shall be AASHTO A709 Grade 36 Steel.
5. See INDOT Standard drawing E 726-BEBP for elastomeric bearing details.
placing Bearing assembly.
4. Finish Bearing Surface shall be clean and free of loose material before in accordance with requirements of A.S.T.M. A123 or A153.
3. Plates and embedded Bearing Plates shall be Hot Dipped Galvanized
2. Structural Steel for Taper Plates shall be ASTM A709, Grade 50.
1. For Beam General Notes and Design Data, see General Plan.
BEARING DETAILS
AS NOTED
AS NOTED
JPL
SH
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
2"4"
2'-0" 2'-0" 2"2"
Detail�See Embedded
1" x 9" x 4'-4"�
S3 x 7.5 x 3'-8"
5/16" Typ
Bridge Seat
Concrete Bulb-Tee Beam 42"x49" Prestressed
9"
Detail�See Embedded
S3 x 7.5 x 3'-8"
1" x 9" x 4'-4"�
(Typ.)
Anchor Bolts
BEARING ASSEMBLY DETAILS
BENT NO. 1 AND NO. 4
1" x 9" x 4'-4"�
S3 x 7.5 x 3'-8"
2" 4"
2" 4"
2" 2"
S3 x 7.5 x 3'-8"
1" x 9" x 4'-4"�
3'-8"
4'-4"
(Flange Width)
3'-4"
S3 x 7.5 x 3'-8" 3/16"
1" x 9" x 4'-4"�
4 1/2 "4 1/2 "
3"3"
END BENT
BEARING ASSEMBLY
Scale: 1"=1'-0"
Scale: 1"=1'-0"
6" x 3'-8" �Taper
6" x 3'-8" �Taper
6" x 3'-8" �Taper 6" x 3'-8"
�Taper
6" x 3'-8" �Taper
END VIEW SIDE VIEW
Bearing�
Beam�
Bearing�
SIDE VIEW END VIEW
L BeamC
7" 1'-1" 1'-1" 7"
7" 2'-2" 7"
Scale: 1"=1'-0"
EMBEDDED BEARING PLATE DETAILS
BENT NO. 1 AND NO. 4
PLAN VIEW
END VIEW
1'-3"
1'-0"3"
Hex Nut
Plate Washer
ANCHOR BOLT DETAIL
Not to Scale
P 5/16" x 2" x 2"L
1" Dia.
PLATE WASHER
Not to Scale
"a
"b
"c"
"d
TAPER PLATE DETAILS
Not to Scale
TAPER PLATE DIMENSIONS
"c" "d""b"Location "a"
CL Brg.
CL Beam
B a c k
S ta ti o n
S ta ti o n
F o rw a rd
1/2" x 3'-2 1/2" x 1'-0" Embedded Plate
ASTM A709, Grade 36
Concrete Bulb-Tee Beam 42"x49" Prestressed
Beam No.
6" 3'-8"1"End Bent 1 1"
6" 3'-8"1"End Bent 4 1 1/8"
ALL
NOTES
6. End Bent Bearing assemblies shall be included in the cost of structural members.
5. Embedded Bearing Plates shall be AASHTO A709 Grade 36 Steel.
placing Bearing Assembly.
4. Finish Bearing Surface shall be clean and free of loose material before in accordance with requirements of A.S.T.M. A123 or A153.
3. Plates and Embedded Bearing Plates shall be Hot Dipped Galvanized
2. Structural Steel for Taper Plates shall be ASTM A709, Grade 50.
1. For Beam General Notes and Design Data, see General Plan.
BEARING DETAILS
1" = 1'-0"
1" = 1'-0"
JPL
SH
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
O u t-to -O u t
C o p in g
Structure and Line "PR-A"�
� Bearing Bent No. 1 & �
M in La p
Brg.� Brg. to �102'-1"
3'-3" Min. Lap (Typ.)
Pier� Bent to �103'-0"
Brg.� Brg. to �83'-2"
Pier� Pier to �85'-0"
292'-6 1/2" Out-to-Out Deck x
/2 (T o p
L in e s o f x x
/2 (B o tt o m
L in e s o f x
16'-0"19'-0"
16'-0" 19'-0"
Pier No. 2�
438 Spa. @ 8" Max. = 292'-0 1/2" (439 - 452 Each Curb, 878 Total) (439 - #4 x 3'-9")
Bearing�
Bearing�
445 Spa. @ 7 7/8" Max. = 292'-0 1/2" (451 Bars in Coping, Spaced w/ #5s, 892 Total in Coping)
445 Spa. @ 7 7/8" Max. = 292'-0 1/2" (446 Lines of 2 - #5 x 37'-8" Bars)
& 1 - #4 X 34'-9 1/2" (Median) 7 Lines of 7 - #4 X 40'-0"
3" (Typ.)
x
G a lv a n iz e d T h re a d e d
T ie
B a r A s s e m b ly
S p a c e s
M a x
T ie d t o B o tt o m
M a t o f D e c k S te e l
(T o p O ve r
P ie rs S ta g g e re d x
11" 11"
Light Pole Sta. 36+25.00
1 - 453 (Bottom) 1 - 453 (Top) &
3'-3" Min. Lap (Typ.)
S 87° 18' 05" E
SUPERSTRUCTURE DETAILS
1/8" = 1'-0"
1/8" = 1'-0"
DDM
SH
DDM
EDM
FLOOR PLAN
Scale: 1/8" = 1'-0" lifting during concrete placement down to the deck forms and/or the beams to prevent The top reinforcing in the deck shall be securely tied
Note on the Layout Sheet.
See the "COORDINATION WITH ROADWAY PLANS"
For Bar Bending Diagrams, See Sheet 28.
For Typical Section, See Sheet 24.
For General Notes, See Sheet 8.
For Additional Superstructure Details, See Sheet 27.
All reinforcing bars to be galvanized.
NOTES:
7.
6.
5.
4.
3.
2.
1.
E P
L O
T T
E D
D A
T E
P L
O T
T E
D
M O
D E
L N
A M
E
P A
T H
A N
D F
IL
E
N A
M E
F
IL
E
L
M
O D
E L
N A
M E
D
A T
E
T
IM
DESIGN ENGINEER DATE
DESIGNED:
CHECKED:
DRAWN:
CHECKED:
PROJECT
DESIGNATION
SHEETS
VERTICAL SCALE
Bridge No. 335
PR-26-0836
No.
G
LAON
S
P R
E F
O
S N
ANIA
I
NI D
STATE OF
E
R E
I N
E
R
EERSTIGE D
PE12500107
07/22/2026
O u t-to -O u t
C o p in g
Structure and Line "PR-A"�
� Bearing Bent No. 4 & �
Bearing�
M in La p
Bearing�
Pier No. 3�
& 1 - #4 X 34'-9 1/2" (Median) 7 Lines of 7 - #4 X 40'-0"
3'-3" Min. Lap (Typ.)
11"
292'-6 1/2" Out-to-Out Deck
Pier� Pier to �85'-0"
Brg.� Brg. to �83'-2"
11"
Pier� Bent to �103'-0"
Brg.� Brg. to �102'-1" x
G a lv a n iz e d T h re a d e d
T ie
B a r A s s e m b ly
S p a c e s
M a x
T ie d t o B o tt o m
M a t o f D e c k S te e l x
/2 (T o p
L in e s o f x x
/2 (B o tt o m
L in e s o f x
(T o p O ve r
P ie rs S ta g g e re d x
19'-0" 16'-0"
16'-0" 19'-0"
445 Spa. @ 7 7/8" Max. = 292'-0 1/2" (451 Bars in Coping, Spaced w/ #5s, 892 Total in Coping)
445 Spa. @ 7 7/8" Max. = 292'-0 1/2" (446 Lines of 2 - #5 x 37'-8" Bars)
Light Pole Sta. 38+15.00
3" (Typ.)
1 - 453 (Bottom) 1 - 453 (Top) &
S 87° 18' 05" E
3'-3" Min. Lap (Typ.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .