This is a Hazardous/Regulated Materials Survey & Inspection Report prepared by Environmental Testing & Consulting, Inc. for the City of Detroit Demolition Department regarding the property at 14627 Burgess Street, Detroit, Michigan (Parcel #22112391). The inspection was conducted on July 30, 2026, with the report finalized on August 14, 2026, as part of Project #2026 BPO 7.20.2026. The survey identified one asbestos-containing material (ACM): white transite siding measuring approximately 1,250 square feet located on exterior areas EA-1 through EA-4. Additionally, two smoke detectors with batteries and two paint cans containing hazardous materials were identified in functional spaces FS-5 and FS-8. An engineering survey completed on July 29, 2026, documented the single-story residential structure built in 1955 with a concrete slab foundation and total square footage of 660 square feet. The property was evaluated for structural integrity, water damage, fire damage, termite damage, and accessibility issues across five exterior areas and eight functional spaces.

The asbestos analysis conducted through polarized light microscopy (PLM) and point count (PC) methods identified chrysotile asbestos in the transite siding and related components, with the siding layer containing 5% asbestos by PLM analysis. The testing revealed that most interior materials (drywall composites, floor tiles, mastics, insulation, and adhesives) tested negative for asbestos or contained trace amounts below the 1% threshold for ACM classification. Exterior materials including cinderblock, mortar, concrete surfaces, caulks, and roofing materials also tested negative for asbestos. The laboratory analysis included 81 bulk samples collected from various locations within the property, with testing completed between August 4-5, 2026. All results were documented with chain of custody procedures and analyzed by certified laboratory personnel. The contractor is responsible for verifying the quantities of identified asbestos during the bid process, and any material containing greater than 1% asbestos content must be treated in accordance with OSHA and EPA regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Hazardous/Regulated Materials Survey & Inspection Report

14627 Burgess Street, Detroit, MI 48223 Parcel #: 22112391.

Date of Inspection: 07/30/2026 Date of Report: 08/14/2026

Prepared For:

City of Detroit Demolition Department

1301 3rd Avenue, 6th Floor

Detroit, MI 48226

Project #: 2026 BPO 7.20.2026

Fieldwork conducted by: Report Reviewed and Approved by:

Andre Richardson Mark Smith Michigan Asbestos Inspector License #: A45125 Michigan Asbestos Inspector License #: A55707 Inspector’s E-Mail: Andre.Richardson@2etc.com E-Mail: Mark.Smith@2etc.com

38900 West Huron River Drive Romulus, MI 48174

734-955-6600 www.2etc.com

Hazardous/Regulated Materials Survey & Inspection Report ETC Job #: 293120

14627 Burgess Street, Detroit, MI 48223 Parcel #: 22112391.

Asbestos Containing Materials

TABLE 1: ASBESTOS CONTAINING MATERIALS

Category Material Description Location Quantity

M Transite Siding, White EA 1-4 1250 SF TSI = Thermal System Insulation; S = Surfacing; M = Miscellaneous; SF= Square Feet; LF = Linear Feet;

CY = Cubic Yards; CF = Cubic Feet

Quantities that are listed are estimates only. It is the contractor’s responsibility to verify all amounts of asbestos identified during the bid process.

Hazardous Materials & Tires

TABLE 2: HAZARDOUS MATERIALS

Material Description Location Quantity

Smoke Detector w/Battery FS 5,8 2

Paint Cans FS 3 2

Engineering Survey

14627 Burgess Street

Reviewed 08/2025

Pre-Demolition Engineering Survey Report

Detroit, MI 48223

Prepared for City of Detroit Demolition Department

1301 Third Street, 6th Floor Detroit, Michigan 48226

Prepared by Environmental Testing & Consulting, Inc.

38900 West Huron River Drive Romulus, MI 48174

Report Date July 29, 2026

Reviewed 08/2025

Survey Details and Site Information Date(s) of Engineering Survey: July 29, 2026

Engineering Survey Inspector name: Jeremy Westcott

Engineering Survey Inspector #: INSP01045

Engineering Survey Inspector email: Jeremy.Westcott@2etc.com

Engineering Survey Inspector phone #: 734-955-6600

Engineering Survey Inspector signature:

Reviewing PE/Architect name:

Reviewing PE/Architect license state/#:

Reviewing PE/Architect email:

Reviewing PE/Architect phone #:

Reviewing PE/Architect signature:

Property Address: 14627 Burgess Street, Detroit, MI 48223

# and types of structure(s): 1 House

Foundation type Concrete Slab

Year built: 1955

# of floors: 1

Total square footage: 660 ft2

William Earle, P.E. (WI)

WI 35407-9

William.Earle@oneatlas.com

847-971-0979

Engineering Survey Findings – Exterior Areas

Designation Inaccessible Reason Description/Notes

EA-1

EA-2

EA-3

EA-4

EA-5

Key:

• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible

• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage

Reviewed 08/2025

Engineering Survey Findings – Functional Spaces

Designation Inaccessible Reason Description/Notes

FS-1

FS-2

FS-3

FS-4

FS-5

FS-6

FS-7

FS-8

Key:

• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible

• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage

Site Drawings

Site Photographs

EA1 EA2

EA3

EA4

EA5 FS1

FS2

FS3

FS4 FS5

FS6

FS7

FS8

Electronic Chain of Custody

Submitting Client:

Detroit, MI - 48226

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Environmental Testing Laboratories, Inc.

City of Detroit - Demolition Department

1301 Third Street - Suite 606

Asbestos-Bulk

72 Hours

Yes

Yes, 0.00 Points

DETROIT DEMO

Sample Type:

Turn Around:

Positive Stop:

Point Counting:

P.C. Criteria:

Sample ID Client Sample ID

ETL Project :Project Location: 29312014627 Burgess, Detroit, MI 48223

Collection DateSample Location Sample Description

1914248 2026-07-301A FS1 Ceiling / Wall / Drywall Composite - White -

HA(1)

1914249 2026-07-301B FS2 Ceiling / Wall / Drywall Composite - White -

HA(1)

1914250 2026-07-301C FS3 Ceiling / Wall / Drywall Composite - White -

HA(1)

1914251 2026-07-302A FS1 Floor / Tile - Brown - HA(2)

1914252 2026-07-302B FS2 Floor / Tile - Brown - HA(2)

1914253 2026-07-302C FS3 Floor / Tile - Brown - HA(2)

1914254 2026-07-303A FS1 Floor / Tile Mastic - Clear - HA(3)

1914255 2026-07-303B FS2 Floor / Tile Mastic - Clear - HA(3)

1914256 2026-07-303C FS3 Floor / Tile Mastic - Clear - HA(3)

1914257 2026-07-304A FS1 Floor / Tile - Cream - HA(4)

1914258 2026-07-304B FS2 Floor / Tile - Cream - HA(4)

1914259 2026-07-304C FS3 Floor / Tile - Cream - HA(4)

1914260 2026-07-305A FS1 Floor / Tile Mastic - Clear - HA(5)

1914261 2026-07-305B FS2 Floor / Tile Mastic - Clear - HA(5)

1914262 2026-07-305C FS3 Floor / Tile Mastic - Clear - HA(5)

1914263 2026-07-306A FS1 Floor / Tile - Beige - HA(6)

1914264 2026-07-306B FS2 Floor / Tile - Beige - HA(6)

1914265 2026-07-306C FS3 Floor / Tile - Beige - HA(6)

1914266 2026-07-307A FS1 Floor / Tile Mastic - Clear - HA(7)

Sample ID Client Sample ID

ETL Project :Project Location: 29312014627 Burgess, Detroit, MI 48223

Collection DateSample Location Sample Description

1914267 2026-07-307B FS2 Floor / Tile Mastic - Clear - HA(7)

1914268 2026-07-307C FS3 Floor / Tile Mastic - Clear - HA(7)

1914269 2026-07-308A FS1 Floor / Tile - Green - HA(8)

1914270 2026-07-308B FS2 Floor / Tile - Green - HA(8)

1914271 2026-07-308C FS3 Floor / Tile - Green - HA(8)

1914272 2026-07-309A FS1 Floor / Tile Mastic - Clear - HA(9)

1914273 2026-07-309B FS2 Floor / Tile Mastic - Clear - HA(9)

1914274 2026-07-309C FS3 Floor / Tile Mastic - Clear - HA(9)

1914275 2026-07-3010A FS8 Insulation / Rolled-In - Brown - HA(10)

1914276 2026-07-3010B FS8 Insulation / Rolled-In - Brown - HA(10)

1914277 2026-07-3010C FS8 Insulation / Rolled-In - Brown - HA(10)

1914278 2026-07-3011A FS6 Adhesive / - - Brown - HA(11)

1914279 2026-07-3011B FS6 Adhesive / - - Brown - HA(11)

1914280 2026-07-3011C FS6 Adhesive / - - Brown - HA(11)

1914281 2026-07-3012A FS6 Caulk / Interior - White - HA(12)

1914282 2026-07-3012B FS6 Caulk / Interior - White - HA(12)

1914283 2026-07-3012C FS6 Caulk / Interior - White - HA(12)

1914284 2026-07-3013A EA1 Cinderblock - Grey - HA(13)

1914285 2026-07-3013B EA2 Cinderblock - Grey - HA(13)

1914286 2026-07-3013C EA3 Cinderblock - Grey - HA(13)

1914287 2026-07-3014A EA1 Mortar / Cinderblock - Grey - HA(14)

1914288 2026-07-3014B EA2 Mortar / Cinderblock - Grey - HA(14)

1914289 2026-07-3014C EA3 Mortar / Cinderblock - Grey - HA(14)

1914290 2026-07-3015A EA1 Concrete / Porch - Grey - HA(15)

1914291 2026-07-3015B EA1 Concrete / Porch - Grey - HA(15)

1914292 2026-07-3015C EA1 Concrete / Porch - Grey - HA(15)

1914293 2026-07-3016A EA1 Concrete / Walkway - Grey - HA(16)

1914294 2026-07-3016B EA2 Concrete / Walkway - Grey - HA(16)

Collection DateSample Location Sample Description

1914295 2026-07-3016C EA3 Concrete / Walkway - Grey - HA(16)

1914296 2026-07-3017A EA2 Concrete / Driveway - Grey - HA(17)

1914297 2026-07-3017B EA2 Concrete / Driveway - Grey - HA(17)

1914298 2026-07-3017C EA2 Concrete / Driveway - Grey - HA(17)

1914299 2026-07-3018A EA1 Caulk / Exterior - Grey - HA(18)

1914300 2026-07-3018B EA2 Caulk / Exterior - Grey - HA(18)

1914301 2026-07-3018C EA3 Caulk / Exterior - Grey - HA(18)

1914302 2026-07-3019A EA1 Transite / Siding - White - HA(19)

1914303 2026-07-3019B EA2 Transite / Siding - White - HA(19)

1914304 2026-07-3019C EA3 Transite / Siding - White - HA(19)

1914305 2026-07-3020A EA1 Transite Seam Tape - Black - HA(20)

1914306 2026-07-3020B EA2 Transite Seam Tape - Black - HA(20)

1914307 2026-07-3020C EA3 Transite Seam Tape - Black - HA(20)

1914308 2026-07-3021A EA1 Wall (Ext.) / Vapor Barrier - Black - HA(21)

1914309 2026-07-3021B EA2 Wall (Ext.) / Vapor Barrier - Black - HA(21)

1914310 2026-07-3021C EA3 Wall (Ext.) / Vapor Barrier - Black - HA(21)

1914311 2026-07-3022A EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)

1914312 2026-07-3022B EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)

1914313 2026-07-3022C EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)

1914314 2026-07-3023A EA5 Roofing / Asphalt (Shingles) - Black and Gray -

HA(23)

1914315 2026-07-3023B EA5 Roofing / Asphalt (Shingles) - Black and Gray -

HA(23)

1914316 2026-07-3023C EA5 Roofing / Asphalt (Shingles) - Black and Gray -

HA(23)

1914317 2026-07-3024A EA5 Roofing / Asphalt (Shingles) - Black - HA(24)

1914318 2026-07-3024B EA5 Roofing / Asphalt (Shingles) - Black - HA(24)

1914319 2026-07-3024C EA5 Roofing / Asphalt (Shingles) - Black - HA(24)

1914320 2026-07-3025A EA5 Roofing / Tar Paper - Black - HA(25)

1914321 2026-07-3025B EA5 Roofing / Tar Paper - Black - HA(25)

Collection DateSample Location Sample Description

1914322 2026-07-3025C EA5 Roofing / Tar Paper - Black - HA(25)

1914323 2026-07-3026A EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)

1914324 2026-07-3026B EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)

1914325 2026-07-3026C EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)

1914326 2026-07-3027A EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)

1914327 2026-07-3027B EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)

1914328 2026-07-3027C EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)

Seal Intact:

Preservative (if required):

Containers Labled :

Yes

Yes

Analyst

Yes

Collection DateSample Location Sample Description

Received By:

Received Date:

Relinquished By:

Relinquished Date:

Bella Rossi

2026-07-31 11:48 AM

Andre Richardson

Jul 31 2026 12:00AM Asha Davidson

Ben Jones

Chris Canilao

OJ Ivey

Teagan Murphy

Material List

Client : City of Detroit - Demolition Department 1301 Third Street - Suite 606 Detroit, MI - 48226

Project Location: 14627 Burgess st. Detroit Mi. Job #:293120

Material Id Material Description Material Sub Classification Size Quantity Locations

1 Ceiling / Wall/D rywall Composite-White Drywall Composite M 5860 S F F S-01,F S-02,F S-03,F S-04,F S-05,F S-06,F S-07

2 F loor/Ti le-B rown Tile M 355 S F F S-01,F S-03,F S-02,F S-06

3 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06

4 F loor/Ti le-C ream Tile M 355 S F F S-01,F S-02,F S-03,F S-06

5 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06

6 F loor/Ti le-Beige Tile M 355 S F F S-01,F S-02,F S-03,F S-06

7 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06

8 F loor/Ti le-Green Tile M 355 S F F S-01,F S-02,F S-03,F S-06

9 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06

10 Insulation/Rolled-In-Brown Rolled-In T 786 S F F S-08

11 Adhesive/--B rown - M 68 S F F S-06

12 Caulk/Interior-White Interior M 10 LF F S-06

13 C inderblock-Grey M 790 S F E A-01,E A-02,E A-03,E A-04

14 Mortar/C inderblock-Grey C inderblock M 790 S F E A-01,E A-02,E A-03,E A-04

15 Concrete/Porch-Grey Porch M 50 S F E A-01

16 Concrete/Walkway-Grey Walkway M 185 S F E A-01,E A-02,E A-03,E A-04

17 Concrete/D riveway-Grey Driveway M 650 S F E A-02

18 Caulk/Exterior-Grey Exterior M 290 LF E A-01,E A-02,E A-03,E A-04

19 Transite/S iding-White S iding M 1250 S F E A-01,E A-02,E A-03,E A-04

20 Transite Seam Tape-B lack 1250 E A-01,E A-02,E A-03,E A-04

21 Wall (Ext.)/Vapor Barrier-B lack Vapor Barrier M 1250 S F E A-01,E A-02,E A-03,E A-04

22 Roofing/Asphalt (Shingles)-Grey Asphalt (Shingles) M 980 S F E A-05

23 Roofing/Asphalt (Shingles)-B lack and Gray Asphalt (Shingles) M 980 S F E A-05

24 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 980 S F E A-05

25 Roofing/Tar Paper-B lack Tar Paper M 980 S F E A-05

26 Roofing/Asphalt (Shingles)-B rown Asphalt (Shingles) M 980 S F E A-05

27 Roofing/Asphalt (Shingles)-B rown Asphalt (Shingles) M 980 S F E A-05

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Environmental Testing And Consulting Inc.

38900 Huron River Drive

Romulus, MI 48174

Project Location: 14627 Burgess, Detroit, MI 48223

REVISED REPORT

Client Project: 293120

293120ETL Job:

Al Dyer

Report Issued: 08/05/2026

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1914248 Asbestos1A 08/05/2026 OJ Ivey07/30/2026

1914249 Asbestos1B 08/05/2026 OJ Ivey07/30/2026

1914250 Asbestos1C 08/05/2026 OJ Ivey07/30/2026

1914251 Asbestos2A 08/05/2026 OJ Ivey07/30/2026

1914252 Asbestos2B 08/05/2026 OJ Ivey07/30/2026

1914253 Asbestos2C 08/05/2026 OJ Ivey07/30/2026

1914254 Asbestos3A 08/05/2026 OJ Ivey07/30/2026

1914255 Asbestos3B 08/05/2026 OJ Ivey07/30/2026

1914256 Asbestos3C 08/05/2026 OJ Ivey07/30/2026

1914257 Asbestos4A 08/05/2026 OJ Ivey07/30/2026

1914258 Asbestos4B 08/05/2026 OJ Ivey07/30/2026

1914259 Asbestos4C 08/05/2026 OJ Ivey07/30/2026

1914260 Asbestos5A 08/05/2026 OJ Ivey07/30/2026

1914261 Asbestos5B 08/05/2026 OJ Ivey07/30/2026

1914262 Asbestos5C 08/05/2026 OJ Ivey07/30/2026

1914263 Asbestos6A 08/05/2026 OJ Ivey07/30/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1914264 Asbestos6B 08/05/2026 OJ Ivey07/30/2026

1914265 Asbestos6C 08/05/2026 OJ Ivey07/30/2026

1914266 Asbestos7A 08/05/2026 OJ Ivey07/30/2026

1914267 Asbestos7B 08/05/2026 OJ Ivey07/30/2026

1914268 Asbestos7C 08/05/2026 OJ Ivey07/30/2026

1914269 Asbestos8A 08/05/2026 OJ Ivey07/30/2026

1914270 Asbestos8B 08/05/2026 OJ Ivey07/30/2026

1914271 Asbestos8C 08/05/2026 OJ Ivey07/30/2026

1914272 Asbestos9A 08/05/2026 OJ Ivey07/30/2026

1914273 Asbestos9B 08/05/2026 OJ Ivey07/30/2026

1914274 Asbestos9C 08/05/2026 OJ Ivey07/30/2026

1914275 Asbestos10A 08/04/2026 Asha Davidson07/30/2026

1914276 Asbestos10B 08/04/2026 Asha Davidson07/30/2026

1914277 Asbestos10C 08/04/2026 Asha Davidson07/30/2026

1914278 Asbestos11A 08/04/2026 Asha Davidson07/30/2026

1914279 Asbestos11B 08/04/2026 Asha Davidson07/30/2026

1914280 Asbestos11C 08/04/2026 Asha Davidson07/30/2026

1914281 Asbestos12A 08/04/2026 Asha Davidson07/30/2026

1914282 Asbestos12B 08/04/2026 Asha Davidson07/30/2026

1914283 Asbestos12C 08/04/2026 Asha Davidson07/30/2026

1914284 Asbestos13A 08/05/2026 OJ Ivey07/30/2026

1914285 Asbestos13B 08/05/2026 OJ Ivey07/30/2026

1914286 Asbestos13C 08/05/2026 OJ Ivey07/30/2026

1914287 Asbestos14A 08/05/2026 OJ Ivey07/30/2026

1914288 Asbestos14B 08/05/2026 OJ Ivey07/30/2026

1914289 Asbestos14C 08/05/2026 OJ Ivey07/30/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

1914290 Asbestos15A 08/05/2026 OJ Ivey07/30/2026

1914291 Asbestos15B 08/05/2026 OJ Ivey07/30/2026

1914292 Asbestos15C 08/05/2026 OJ Ivey07/30/2026

1914293 Asbestos16A 08/05/2026 Ben Jones07/30/2026

1914294 Asbestos16B 08/05/2026 Ben Jones07/30/2026

1914295 Asbestos16C 08/05/2026 Ben Jones07/30/2026

1914296 Asbestos17A 08/05/2026 Ben Jones07/30/2026

1914297 Asbestos17B 08/05/2026 Ben Jones07/30/2026

1914298 Asbestos17C 08/05/2026 Ben Jones07/30/2026

1914299 Asbestos18A 08/05/2026 Ben Jones07/30/2026

1914300 Asbestos18B 08/05/2026 Ben Jones07/30/2026

1914301 Asbestos18C 08/05/2026 Ben Jones07/30/2026

1914302 Asbestos19A 08/05/2026 Teagan Murphy07/30/2026

1914303 Asbestos19B 08/05/2026 Teagan Murphy07/30/2026

1914304 Asbestos19C 08/05/2026 Teagan Murphy07/30/2026

1914305 Asbestos20A 08/05/2026 Teagan Murphy07/30/2026

1914306 Asbestos20B 08/05/2026 Teagan Murphy07/30/2026

1914307 Asbestos20C 08/05/2026 Teagan Murphy07/30/2026

1914308 Asbestos21A 08/05/2026 Teagan Murphy07/30/2026

1914309 Asbestos21B 08/05/2026 Teagan Murphy07/30/2026

1914310 Asbestos21C 08/05/2026 Teagan Murphy07/30/2026

1914311 Asbestos22A 08/05/2026 Teagan Murphy07/30/2026

1914312 Asbestos22B 08/05/2026 Teagan Murphy07/30/2026

1914313 Asbestos22C 08/05/2026 Teagan Murphy07/30/2026

1914314 Asbestos23A 08/05/2026 Teagan Murphy07/30/2026

1914315 Asbestos23B 08/05/2026 Teagan Murphy07/30/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

1914316 Asbestos23C 08/05/2026 Teagan Murphy07/30/2026

1914317 Asbestos24A 08/05/2026 Chris Canilao07/30/2026

1914318 Asbestos24B 08/05/2026 Chris Canilao07/30/2026

1914319 Asbestos24C 08/05/2026 Chris Canilao07/30/2026

1914320 Asbestos25A 08/05/2026 Chris Canilao07/30/2026

1914321 Asbestos25B 08/05/2026 Chris Canilao07/30/2026

1914322 Asbestos25C 08/05/2026 Chris Canilao07/30/2026

1914323 Asbestos26A 08/05/2026 Chris Canilao07/30/2026

1914324 Asbestos26B 08/05/2026 Chris Canilao07/30/2026

1914325 Asbestos26C 08/05/2026 Chris Canilao07/30/2026

1914326 Asbestos27A 08/05/2026 Chris Canilao07/30/2026

1914327 Asbestos27B 08/05/2026 Chris Canilao07/30/2026

1914328 Asbestos27C 08/05/2026 Chris Canilao07/30/2026

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 87 7

Point Count 3

Dawson Bradley

Revision History

Revision CommentRevised ByRevised Date

Eleni Kiliaris Collection Date Corrected by Client08/14/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914248

1A PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall

Composite - White - HA(1) Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PC 0.5% Chrysotile1914248

1A PC 98.5% OtherPC 1% CelluloseGrey / TanMud

Non-Fibrous

HomogenousFS1

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914248

1A PLM 60% OtherPLM 40% CelluloseBeigeTape

Fibrous

HomogenousFS1

Layer-3 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914249

1B PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall

Composite - White - HA(1) Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PC 0.75% Chrysotile1914249

1B PC 98.5% OtherPC 0.75% CelluloseGrey / TanMud

Non-Fibrous

HomogenousFS2

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914249

1B PLM 60% OtherPLM 40% CelluloseBeigeTape

Fibrous

HomogenousFS2

Layer-3 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914250

1C PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall

Composite - White - HA(1) Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PC 0.5% Chrysotile1914250

1C PC 98.5% OtherPC 1% CelluloseGrey / TanMud

Non-Fibrous

HomogenousFS3

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914250

1C PLM 60% OtherPLM 40% CelluloseBeigeTape

Fibrous

HomogenousFS3

Layer-3 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914251

2A PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)

Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914251

2A PLM 99% OtherPLM 1% CelluloseBlackMastic

Non-Fibrous

HomogenousFS1

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914252

2B PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)

Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914252

2B PLM 99% OtherPLM 1% CelluloseBlackMastic

Non-Fibrous

HomogenousFS2

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914253

2C PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)

Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914253

2C PLM 99% OtherPLM 1% CelluloseBlackMastic

Non-Fibrous

HomogenousFS3

Layer-2 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914254

3A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(3) Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914255

3B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(3) Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914256

3C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(3) Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914257

4A PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)

Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914258

4B PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)

Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914259

4C PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)

Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914260

5A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(5) Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914261

5B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(5) Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914262

5C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(5) Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914263

6A PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)

Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914264

6B PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)

Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914265

6C PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)

Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914266

7A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(7) Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914267

7B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(7) Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914268

7C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(7) Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914269

8A PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)

Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914270

8B PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)

Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914271

8C PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)

Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914272

9A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(9) Non-Fibrous

HomogenousFS1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914273

9B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(9) Non-Fibrous

HomogenousFS2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914274

9C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -

HA(9) Non-Fibrous

HomogenousFS3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914275

10A PLM 100% OtherBrownInsulation / Rolled-In - Brown -

HA(10) Fibrous

HomogenousFS8

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914275

10A PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing

Fibrous

HomogenousFS8

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914276

10B PLM 100% OtherBrownInsulation / Rolled-In - Brown -

HA(10) Fibrous

HomogenousFS8

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914276

10B PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing

Fibrous

HomogenousFS8

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914277

10C PLM 100% OtherBrownInsulation / Rolled-In - Brown -

HA(10) Fibrous

HomogenousFS8

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914277

10C PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing

Fibrous

HomogenousFS8

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914278

11A PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)

Non-Fibrous

Non-HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

With Powdery Material

PLM None Detected 1914279

11B PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)

Non-Fibrous

Non-HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

With Powdery Material

PLM None Detected 1914279

11B PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material

Non-Fibrous

HomogenousFS6

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914280

11C PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)

Non-Fibrous

Non-HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

With Powdery Material

PLM None Detected 1914280

11C PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material

Non-Fibrous

HomogenousFS6

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914281

12A PLM 100% OtherPLM Trace CelluloseWhite/TanCaulk / Interior - White - HA(12)

Non-Fibrous

Non-HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

With Adhesive

PLM None Detected 1914282

12B PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(12)

Non-Fibrous

HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914283

12C PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(12)

Non-Fibrous

HomogenousFS6

Layer-1 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

PLM None Detected 1914283

12C PLM 100% OtherPLM Trace CelluloseTanAdhesive

Non-Fibrous

HomogenousFS6

Layer-2 Analyst: Asha Davidson

Date Analyzed : 08/04/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914284

13A PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)

Non-Fibrous

HomogenousEA1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914285

13B PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)

Non-Fibrous

HomogenousEA2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914286

13C PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)

Non-Fibrous

HomogenousEA3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914287

14A PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -

HA(14) Non-Fibrous

HomogenousEA1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914288

14B PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -

HA(14) Non-Fibrous

HomogenousEA2

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914289

14C PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -

HA(14) Non-Fibrous

HomogenousEA3

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914290

15A PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)

Non-Fibrous

HomogenousEA1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914291

15B PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)

Non-Fibrous

HomogenousEA1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914292

15C PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)

Non-Fibrous

HomogenousEA1

Layer-1 Analyst: OJ Ivey

Date Analyzed : 08/05/2026

PLM None Detected 1914293

16A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -

HA(16) Non-Fibrous

HomogenousEA1

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914294

16B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -

HA(16) Non-Fibrous

HomogenousEA2

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914295

16C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -

HA(16) Non-Fibrous

HomogenousEA3

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Romulus,MI 48174

Environmental Testing And Consulting Inc.

38900 Huron River Drive

14627 Burgess, Detroit, MI 48223

ETL Job :

Client Project :

293120

293120

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

07/30/2026

07/31/2026

Date Collected :

Date Received :

PLM None Detected 1914296

17A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -

HA(17) Non-Fibrous

HomogenousEA2

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914297

17B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -

HA(17) Non-Fibrous

HomogenousEA2

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914298

17C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -

HA(17) Non-Fibrous

HomogenousEA2

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914299

18A PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)

Non-Fibrous

HomogenousEA1

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914300

18B PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)

Non-Fibrous

HomogenousEA2

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

PLM None Detected 1914301

18C PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)

Non-Fibrous

HomogenousEA3

Layer-1 Analyst: Ben Jones

Date Analyzed : 08/05/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM).

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .