This is a Hazardous/Regulated Materials Survey & Inspection Report prepared by Environmental Testing & Consulting, Inc. for the City of Detroit Demolition Department regarding the property at 14627 Burgess Street, Detroit, Michigan (Parcel #22112391). The inspection was conducted on July 30, 2026, with the report finalized on August 14, 2026, as part of Project #2026 BPO 7.20.2026. The survey identified one asbestos-containing material (ACM): white transite siding measuring approximately 1,250 square feet located on exterior areas EA-1 through EA-4. Additionally, two smoke detectors with batteries and two paint cans containing hazardous materials were identified in functional spaces FS-5 and FS-8. An engineering survey completed on July 29, 2026, documented the single-story residential structure built in 1955 with a concrete slab foundation and total square footage of 660 square feet. The property was evaluated for structural integrity, water damage, fire damage, termite damage, and accessibility issues across five exterior areas and eight functional spaces.
The asbestos analysis conducted through polarized light microscopy (PLM) and point count (PC) methods identified chrysotile asbestos in the transite siding and related components, with the siding layer containing 5% asbestos by PLM analysis. The testing revealed that most interior materials (drywall composites, floor tiles, mastics, insulation, and adhesives) tested negative for asbestos or contained trace amounts below the 1% threshold for ACM classification. Exterior materials including cinderblock, mortar, concrete surfaces, caulks, and roofing materials also tested negative for asbestos. The laboratory analysis included 81 bulk samples collected from various locations within the property, with testing completed between August 4-5, 2026. All results were documented with chain of custody procedures and analyzed by certified laboratory personnel. The contractor is responsible for verifying the quantities of identified asbestos during the bid process, and any material containing greater than 1% asbestos content must be treated in accordance with OSHA and EPA regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous/Regulated Materials Survey & Inspection Report
14627 Burgess Street, Detroit, MI 48223 Parcel #: 22112391.
Date of Inspection: 07/30/2026 Date of Report: 08/14/2026
Prepared For:
City of Detroit Demolition Department
1301 3rd Avenue, 6th Floor
Detroit, MI 48226
Project #: 2026 BPO 7.20.2026
Fieldwork conducted by: Report Reviewed and Approved by:
Andre Richardson Mark Smith Michigan Asbestos Inspector License #: A45125 Michigan Asbestos Inspector License #: A55707 Inspector’s E-Mail: Andre.Richardson@2etc.com E-Mail: Mark.Smith@2etc.com
38900 West Huron River Drive Romulus, MI 48174
734-955-6600 www.2etc.com
Hazardous/Regulated Materials Survey & Inspection Report ETC Job #: 293120
14627 Burgess Street, Detroit, MI 48223 Parcel #: 22112391.
Asbestos Containing Materials
TABLE 1: ASBESTOS CONTAINING MATERIALS
Category Material Description Location Quantity
M Transite Siding, White EA 1-4 1250 SF TSI = Thermal System Insulation; S = Surfacing; M = Miscellaneous; SF= Square Feet; LF = Linear Feet;
CY = Cubic Yards; CF = Cubic Feet
Quantities that are listed are estimates only. It is the contractor’s responsibility to verify all amounts of asbestos identified during the bid process.
Hazardous Materials & Tires
TABLE 2: HAZARDOUS MATERIALS
Material Description Location Quantity
Smoke Detector w/Battery FS 5,8 2
Paint Cans FS 3 2
Engineering Survey
14627 Burgess Street
Reviewed 08/2025
Pre-Demolition Engineering Survey Report
Detroit, MI 48223
Prepared for City of Detroit Demolition Department
1301 Third Street, 6th Floor Detroit, Michigan 48226
Prepared by Environmental Testing & Consulting, Inc.
38900 West Huron River Drive Romulus, MI 48174
Report Date July 29, 2026
Reviewed 08/2025
Survey Details and Site Information Date(s) of Engineering Survey: July 29, 2026
Engineering Survey Inspector name: Jeremy Westcott
Engineering Survey Inspector #: INSP01045
Engineering Survey Inspector email: Jeremy.Westcott@2etc.com
Engineering Survey Inspector phone #: 734-955-6600
Engineering Survey Inspector signature:
Reviewing PE/Architect name:
Reviewing PE/Architect license state/#:
Reviewing PE/Architect email:
Reviewing PE/Architect phone #:
Reviewing PE/Architect signature:
Property Address: 14627 Burgess Street, Detroit, MI 48223
# and types of structure(s): 1 House
Foundation type Concrete Slab
Year built: 1955
# of floors: 1
Total square footage: 660 ft2
William Earle, P.E. (WI)
WI 35407-9
William.Earle@oneatlas.com
847-971-0979
Engineering Survey Findings – Exterior Areas
Designation Inaccessible Reason Description/Notes
EA-1
EA-2
EA-3
EA-4
EA-5
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Reviewed 08/2025
Engineering Survey Findings – Functional Spaces
Designation Inaccessible Reason Description/Notes
FS-1
FS-2
FS-3
FS-4
FS-5
FS-6
FS-7
FS-8
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Site Drawings
Site Photographs
EA1 EA2
EA3
EA4
EA5 FS1
FS2
FS3
FS4 FS5
FS6
FS7
FS8
Electronic Chain of Custody
Submitting Client:
Detroit, MI - 48226
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Environmental Testing Laboratories, Inc.
City of Detroit - Demolition Department
1301 Third Street - Suite 606
Asbestos-Bulk
72 Hours
Yes
Yes, 0.00 Points
DETROIT DEMO
Sample Type:
Turn Around:
Positive Stop:
Point Counting:
P.C. Criteria:
Sample ID Client Sample ID
ETL Project :Project Location: 29312014627 Burgess, Detroit, MI 48223
Collection DateSample Location Sample Description
1914248 2026-07-301A FS1 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914249 2026-07-301B FS2 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914250 2026-07-301C FS3 Ceiling / Wall / Drywall Composite - White -
HA(1)
1914251 2026-07-302A FS1 Floor / Tile - Brown - HA(2)
1914252 2026-07-302B FS2 Floor / Tile - Brown - HA(2)
1914253 2026-07-302C FS3 Floor / Tile - Brown - HA(2)
1914254 2026-07-303A FS1 Floor / Tile Mastic - Clear - HA(3)
1914255 2026-07-303B FS2 Floor / Tile Mastic - Clear - HA(3)
1914256 2026-07-303C FS3 Floor / Tile Mastic - Clear - HA(3)
1914257 2026-07-304A FS1 Floor / Tile - Cream - HA(4)
1914258 2026-07-304B FS2 Floor / Tile - Cream - HA(4)
1914259 2026-07-304C FS3 Floor / Tile - Cream - HA(4)
1914260 2026-07-305A FS1 Floor / Tile Mastic - Clear - HA(5)
1914261 2026-07-305B FS2 Floor / Tile Mastic - Clear - HA(5)
1914262 2026-07-305C FS3 Floor / Tile Mastic - Clear - HA(5)
1914263 2026-07-306A FS1 Floor / Tile - Beige - HA(6)
1914264 2026-07-306B FS2 Floor / Tile - Beige - HA(6)
1914265 2026-07-306C FS3 Floor / Tile - Beige - HA(6)
1914266 2026-07-307A FS1 Floor / Tile Mastic - Clear - HA(7)
Sample ID Client Sample ID
ETL Project :Project Location: 29312014627 Burgess, Detroit, MI 48223
Collection DateSample Location Sample Description
1914267 2026-07-307B FS2 Floor / Tile Mastic - Clear - HA(7)
1914268 2026-07-307C FS3 Floor / Tile Mastic - Clear - HA(7)
1914269 2026-07-308A FS1 Floor / Tile - Green - HA(8)
1914270 2026-07-308B FS2 Floor / Tile - Green - HA(8)
1914271 2026-07-308C FS3 Floor / Tile - Green - HA(8)
1914272 2026-07-309A FS1 Floor / Tile Mastic - Clear - HA(9)
1914273 2026-07-309B FS2 Floor / Tile Mastic - Clear - HA(9)
1914274 2026-07-309C FS3 Floor / Tile Mastic - Clear - HA(9)
1914275 2026-07-3010A FS8 Insulation / Rolled-In - Brown - HA(10)
1914276 2026-07-3010B FS8 Insulation / Rolled-In - Brown - HA(10)
1914277 2026-07-3010C FS8 Insulation / Rolled-In - Brown - HA(10)
1914278 2026-07-3011A FS6 Adhesive / - - Brown - HA(11)
1914279 2026-07-3011B FS6 Adhesive / - - Brown - HA(11)
1914280 2026-07-3011C FS6 Adhesive / - - Brown - HA(11)
1914281 2026-07-3012A FS6 Caulk / Interior - White - HA(12)
1914282 2026-07-3012B FS6 Caulk / Interior - White - HA(12)
1914283 2026-07-3012C FS6 Caulk / Interior - White - HA(12)
1914284 2026-07-3013A EA1 Cinderblock - Grey - HA(13)
1914285 2026-07-3013B EA2 Cinderblock - Grey - HA(13)
1914286 2026-07-3013C EA3 Cinderblock - Grey - HA(13)
1914287 2026-07-3014A EA1 Mortar / Cinderblock - Grey - HA(14)
1914288 2026-07-3014B EA2 Mortar / Cinderblock - Grey - HA(14)
1914289 2026-07-3014C EA3 Mortar / Cinderblock - Grey - HA(14)
1914290 2026-07-3015A EA1 Concrete / Porch - Grey - HA(15)
1914291 2026-07-3015B EA1 Concrete / Porch - Grey - HA(15)
1914292 2026-07-3015C EA1 Concrete / Porch - Grey - HA(15)
1914293 2026-07-3016A EA1 Concrete / Walkway - Grey - HA(16)
1914294 2026-07-3016B EA2 Concrete / Walkway - Grey - HA(16)
Collection DateSample Location Sample Description
1914295 2026-07-3016C EA3 Concrete / Walkway - Grey - HA(16)
1914296 2026-07-3017A EA2 Concrete / Driveway - Grey - HA(17)
1914297 2026-07-3017B EA2 Concrete / Driveway - Grey - HA(17)
1914298 2026-07-3017C EA2 Concrete / Driveway - Grey - HA(17)
1914299 2026-07-3018A EA1 Caulk / Exterior - Grey - HA(18)
1914300 2026-07-3018B EA2 Caulk / Exterior - Grey - HA(18)
1914301 2026-07-3018C EA3 Caulk / Exterior - Grey - HA(18)
1914302 2026-07-3019A EA1 Transite / Siding - White - HA(19)
1914303 2026-07-3019B EA2 Transite / Siding - White - HA(19)
1914304 2026-07-3019C EA3 Transite / Siding - White - HA(19)
1914305 2026-07-3020A EA1 Transite Seam Tape - Black - HA(20)
1914306 2026-07-3020B EA2 Transite Seam Tape - Black - HA(20)
1914307 2026-07-3020C EA3 Transite Seam Tape - Black - HA(20)
1914308 2026-07-3021A EA1 Wall (Ext.) / Vapor Barrier - Black - HA(21)
1914309 2026-07-3021B EA2 Wall (Ext.) / Vapor Barrier - Black - HA(21)
1914310 2026-07-3021C EA3 Wall (Ext.) / Vapor Barrier - Black - HA(21)
1914311 2026-07-3022A EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)
1914312 2026-07-3022B EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)
1914313 2026-07-3022C EA5 Roofing / Asphalt (Shingles) - Grey - HA(22)
1914314 2026-07-3023A EA5 Roofing / Asphalt (Shingles) - Black and Gray -
HA(23)
1914315 2026-07-3023B EA5 Roofing / Asphalt (Shingles) - Black and Gray -
HA(23)
1914316 2026-07-3023C EA5 Roofing / Asphalt (Shingles) - Black and Gray -
HA(23)
1914317 2026-07-3024A EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914318 2026-07-3024B EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914319 2026-07-3024C EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1914320 2026-07-3025A EA5 Roofing / Tar Paper - Black - HA(25)
1914321 2026-07-3025B EA5 Roofing / Tar Paper - Black - HA(25)
Collection DateSample Location Sample Description
1914322 2026-07-3025C EA5 Roofing / Tar Paper - Black - HA(25)
1914323 2026-07-3026A EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)
1914324 2026-07-3026B EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)
1914325 2026-07-3026C EA5 Roofing / Asphalt (Shingles) - Brown - HA(26)
1914326 2026-07-3027A EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)
1914327 2026-07-3027B EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)
1914328 2026-07-3027C EA5 Roofing / Asphalt (Shingles) - Brown - HA(27)
Seal Intact:
Preservative (if required):
Containers Labled :
Yes
Yes
Analyst
Yes
Collection DateSample Location Sample Description
Received By:
Received Date:
Relinquished By:
Relinquished Date:
Bella Rossi
2026-07-31 11:48 AM
Andre Richardson
Jul 31 2026 12:00AM Asha Davidson
Ben Jones
Chris Canilao
OJ Ivey
Teagan Murphy
Material List
Client : City of Detroit - Demolition Department 1301 Third Street - Suite 606 Detroit, MI - 48226
Project Location: 14627 Burgess st. Detroit Mi. Job #:293120
Material Id Material Description Material Sub Classification Size Quantity Locations
1 Ceiling / Wall/D rywall Composite-White Drywall Composite M 5860 S F F S-01,F S-02,F S-03,F S-04,F S-05,F S-06,F S-07
2 F loor/Ti le-B rown Tile M 355 S F F S-01,F S-03,F S-02,F S-06
3 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06
4 F loor/Ti le-C ream Tile M 355 S F F S-01,F S-02,F S-03,F S-06
5 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06
6 F loor/Ti le-Beige Tile M 355 S F F S-01,F S-02,F S-03,F S-06
7 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06
8 F loor/Ti le-Green Tile M 355 S F F S-01,F S-02,F S-03,F S-06
9 F loor/Ti le Mastic-C lear Ti le Mastic M 355 S F F S-01,F S-02,F S-03,F S-06
10 Insulation/Rolled-In-Brown Rolled-In T 786 S F F S-08
11 Adhesive/--B rown - M 68 S F F S-06
12 Caulk/Interior-White Interior M 10 LF F S-06
13 C inderblock-Grey M 790 S F E A-01,E A-02,E A-03,E A-04
14 Mortar/C inderblock-Grey C inderblock M 790 S F E A-01,E A-02,E A-03,E A-04
15 Concrete/Porch-Grey Porch M 50 S F E A-01
16 Concrete/Walkway-Grey Walkway M 185 S F E A-01,E A-02,E A-03,E A-04
17 Concrete/D riveway-Grey Driveway M 650 S F E A-02
18 Caulk/Exterior-Grey Exterior M 290 LF E A-01,E A-02,E A-03,E A-04
19 Transite/S iding-White S iding M 1250 S F E A-01,E A-02,E A-03,E A-04
20 Transite Seam Tape-B lack 1250 E A-01,E A-02,E A-03,E A-04
21 Wall (Ext.)/Vapor Barrier-B lack Vapor Barrier M 1250 S F E A-01,E A-02,E A-03,E A-04
22 Roofing/Asphalt (Shingles)-Grey Asphalt (Shingles) M 980 S F E A-05
23 Roofing/Asphalt (Shingles)-B lack and Gray Asphalt (Shingles) M 980 S F E A-05
24 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 980 S F E A-05
25 Roofing/Tar Paper-B lack Tar Paper M 980 S F E A-05
26 Roofing/Asphalt (Shingles)-B rown Asphalt (Shingles) M 980 S F E A-05
27 Roofing/Asphalt (Shingles)-B rown Asphalt (Shingles) M 980 S F E A-05
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Environmental Testing And Consulting Inc.
38900 Huron River Drive
Romulus, MI 48174
Project Location: 14627 Burgess, Detroit, MI 48223
REVISED REPORT
Client Project: 293120
293120ETL Job:
Al Dyer
Report Issued: 08/05/2026
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1914248 Asbestos1A 08/05/2026 OJ Ivey07/30/2026
1914249 Asbestos1B 08/05/2026 OJ Ivey07/30/2026
1914250 Asbestos1C 08/05/2026 OJ Ivey07/30/2026
1914251 Asbestos2A 08/05/2026 OJ Ivey07/30/2026
1914252 Asbestos2B 08/05/2026 OJ Ivey07/30/2026
1914253 Asbestos2C 08/05/2026 OJ Ivey07/30/2026
1914254 Asbestos3A 08/05/2026 OJ Ivey07/30/2026
1914255 Asbestos3B 08/05/2026 OJ Ivey07/30/2026
1914256 Asbestos3C 08/05/2026 OJ Ivey07/30/2026
1914257 Asbestos4A 08/05/2026 OJ Ivey07/30/2026
1914258 Asbestos4B 08/05/2026 OJ Ivey07/30/2026
1914259 Asbestos4C 08/05/2026 OJ Ivey07/30/2026
1914260 Asbestos5A 08/05/2026 OJ Ivey07/30/2026
1914261 Asbestos5B 08/05/2026 OJ Ivey07/30/2026
1914262 Asbestos5C 08/05/2026 OJ Ivey07/30/2026
1914263 Asbestos6A 08/05/2026 OJ Ivey07/30/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1914264 Asbestos6B 08/05/2026 OJ Ivey07/30/2026
1914265 Asbestos6C 08/05/2026 OJ Ivey07/30/2026
1914266 Asbestos7A 08/05/2026 OJ Ivey07/30/2026
1914267 Asbestos7B 08/05/2026 OJ Ivey07/30/2026
1914268 Asbestos7C 08/05/2026 OJ Ivey07/30/2026
1914269 Asbestos8A 08/05/2026 OJ Ivey07/30/2026
1914270 Asbestos8B 08/05/2026 OJ Ivey07/30/2026
1914271 Asbestos8C 08/05/2026 OJ Ivey07/30/2026
1914272 Asbestos9A 08/05/2026 OJ Ivey07/30/2026
1914273 Asbestos9B 08/05/2026 OJ Ivey07/30/2026
1914274 Asbestos9C 08/05/2026 OJ Ivey07/30/2026
1914275 Asbestos10A 08/04/2026 Asha Davidson07/30/2026
1914276 Asbestos10B 08/04/2026 Asha Davidson07/30/2026
1914277 Asbestos10C 08/04/2026 Asha Davidson07/30/2026
1914278 Asbestos11A 08/04/2026 Asha Davidson07/30/2026
1914279 Asbestos11B 08/04/2026 Asha Davidson07/30/2026
1914280 Asbestos11C 08/04/2026 Asha Davidson07/30/2026
1914281 Asbestos12A 08/04/2026 Asha Davidson07/30/2026
1914282 Asbestos12B 08/04/2026 Asha Davidson07/30/2026
1914283 Asbestos12C 08/04/2026 Asha Davidson07/30/2026
1914284 Asbestos13A 08/05/2026 OJ Ivey07/30/2026
1914285 Asbestos13B 08/05/2026 OJ Ivey07/30/2026
1914286 Asbestos13C 08/05/2026 OJ Ivey07/30/2026
1914287 Asbestos14A 08/05/2026 OJ Ivey07/30/2026
1914288 Asbestos14B 08/05/2026 OJ Ivey07/30/2026
1914289 Asbestos14C 08/05/2026 OJ Ivey07/30/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1914290 Asbestos15A 08/05/2026 OJ Ivey07/30/2026
1914291 Asbestos15B 08/05/2026 OJ Ivey07/30/2026
1914292 Asbestos15C 08/05/2026 OJ Ivey07/30/2026
1914293 Asbestos16A 08/05/2026 Ben Jones07/30/2026
1914294 Asbestos16B 08/05/2026 Ben Jones07/30/2026
1914295 Asbestos16C 08/05/2026 Ben Jones07/30/2026
1914296 Asbestos17A 08/05/2026 Ben Jones07/30/2026
1914297 Asbestos17B 08/05/2026 Ben Jones07/30/2026
1914298 Asbestos17C 08/05/2026 Ben Jones07/30/2026
1914299 Asbestos18A 08/05/2026 Ben Jones07/30/2026
1914300 Asbestos18B 08/05/2026 Ben Jones07/30/2026
1914301 Asbestos18C 08/05/2026 Ben Jones07/30/2026
1914302 Asbestos19A 08/05/2026 Teagan Murphy07/30/2026
1914303 Asbestos19B 08/05/2026 Teagan Murphy07/30/2026
1914304 Asbestos19C 08/05/2026 Teagan Murphy07/30/2026
1914305 Asbestos20A 08/05/2026 Teagan Murphy07/30/2026
1914306 Asbestos20B 08/05/2026 Teagan Murphy07/30/2026
1914307 Asbestos20C 08/05/2026 Teagan Murphy07/30/2026
1914308 Asbestos21A 08/05/2026 Teagan Murphy07/30/2026
1914309 Asbestos21B 08/05/2026 Teagan Murphy07/30/2026
1914310 Asbestos21C 08/05/2026 Teagan Murphy07/30/2026
1914311 Asbestos22A 08/05/2026 Teagan Murphy07/30/2026
1914312 Asbestos22B 08/05/2026 Teagan Murphy07/30/2026
1914313 Asbestos22C 08/05/2026 Teagan Murphy07/30/2026
1914314 Asbestos23A 08/05/2026 Teagan Murphy07/30/2026
1914315 Asbestos23B 08/05/2026 Teagan Murphy07/30/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1914316 Asbestos23C 08/05/2026 Teagan Murphy07/30/2026
1914317 Asbestos24A 08/05/2026 Chris Canilao07/30/2026
1914318 Asbestos24B 08/05/2026 Chris Canilao07/30/2026
1914319 Asbestos24C 08/05/2026 Chris Canilao07/30/2026
1914320 Asbestos25A 08/05/2026 Chris Canilao07/30/2026
1914321 Asbestos25B 08/05/2026 Chris Canilao07/30/2026
1914322 Asbestos25C 08/05/2026 Chris Canilao07/30/2026
1914323 Asbestos26A 08/05/2026 Chris Canilao07/30/2026
1914324 Asbestos26B 08/05/2026 Chris Canilao07/30/2026
1914325 Asbestos26C 08/05/2026 Chris Canilao07/30/2026
1914326 Asbestos27A 08/05/2026 Chris Canilao07/30/2026
1914327 Asbestos27B 08/05/2026 Chris Canilao07/30/2026
1914328 Asbestos27C 08/05/2026 Chris Canilao07/30/2026
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 87 7
Point Count 3
Dawson Bradley
Revision History
Revision CommentRevised ByRevised Date
Eleni Kiliaris Collection Date Corrected by Client08/14/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914248
1A PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PC 0.5% Chrysotile1914248
1A PC 98.5% OtherPC 1% CelluloseGrey / TanMud
Non-Fibrous
HomogenousFS1
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914248
1A PLM 60% OtherPLM 40% CelluloseBeigeTape
Fibrous
HomogenousFS1
Layer-3 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914249
1B PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PC 0.75% Chrysotile1914249
1B PC 98.5% OtherPC 0.75% CelluloseGrey / TanMud
Non-Fibrous
HomogenousFS2
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914249
1B PLM 60% OtherPLM 40% CelluloseBeigeTape
Fibrous
HomogenousFS2
Layer-3 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914250
1C PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(1) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PC 0.5% Chrysotile1914250
1C PC 98.5% OtherPC 1% CelluloseGrey / TanMud
Non-Fibrous
HomogenousFS3
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914250
1C PLM 60% OtherPLM 40% CelluloseBeigeTape
Fibrous
HomogenousFS3
Layer-3 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914251
2A PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914251
2A PLM 99% OtherPLM 1% CelluloseBlackMastic
Non-Fibrous
HomogenousFS1
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914252
2B PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914252
2B PLM 99% OtherPLM 1% CelluloseBlackMastic
Non-Fibrous
HomogenousFS2
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914253
2C PLM 98% OtherPLM 2% CelluloseBrownFloor / Tile - Brown - HA(2)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914253
2C PLM 99% OtherPLM 1% CelluloseBlackMastic
Non-Fibrous
HomogenousFS3
Layer-2 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914254
3A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(3) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914255
3B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(3) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914256
3C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(3) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914257
4A PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914258
4B PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914259
4C PLM 98% OtherPLM 2% CelluloseCreamFloor / Tile - Cream - HA(4)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914260
5A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(5) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914261
5B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(5) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914262
5C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(5) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914263
6A PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914264
6B PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914265
6C PLM 98% OtherPLM 2% CelluloseBeigeFloor / Tile - Beige - HA(6)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914266
7A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(7) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914267
7B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(7) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914268
7C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(7) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914269
8A PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914270
8B PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914271
8C PLM 98% OtherPLM 2% CelluloseGreenFloor / Tile - Green - HA(8)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914272
9A PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(9) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914273
9B PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(9) Non-Fibrous
HomogenousFS2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914274
9C PLM 99% OtherPLM 1% CelluloseClearFloor / Tile Mastic - Clear -
HA(9) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914275
10A PLM 100% OtherBrownInsulation / Rolled-In - Brown -
HA(10) Fibrous
HomogenousFS8
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914275
10A PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing
Fibrous
HomogenousFS8
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914276
10B PLM 100% OtherBrownInsulation / Rolled-In - Brown -
HA(10) Fibrous
HomogenousFS8
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914276
10B PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing
Fibrous
HomogenousFS8
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914277
10C PLM 100% OtherBrownInsulation / Rolled-In - Brown -
HA(10) Fibrous
HomogenousFS8
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914277
10C PLM 5% OtherPLM 95% CelluloseBrown/BlackPaper Backing
Fibrous
HomogenousFS8
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914278
11A PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)
Non-Fibrous
Non-HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
With Powdery Material
PLM None Detected 1914279
11B PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)
Non-Fibrous
Non-HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
With Powdery Material
PLM None Detected 1914279
11B PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material
Non-Fibrous
HomogenousFS6
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914280
11C PLM 100% OtherPLM Trace CelluloseBrown/WhiteAdhesive / - - Brown - HA(11)
Non-Fibrous
Non-HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
With Powdery Material
PLM None Detected 1914280
11C PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material
Non-Fibrous
HomogenousFS6
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914281
12A PLM 100% OtherPLM Trace CelluloseWhite/TanCaulk / Interior - White - HA(12)
Non-Fibrous
Non-HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
With Adhesive
PLM None Detected 1914282
12B PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(12)
Non-Fibrous
HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914283
12C PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(12)
Non-Fibrous
HomogenousFS6
Layer-1 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
PLM None Detected 1914283
12C PLM 100% OtherPLM Trace CelluloseTanAdhesive
Non-Fibrous
HomogenousFS6
Layer-2 Analyst: Asha Davidson
Date Analyzed : 08/04/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914284
13A PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914285
13B PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)
Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914286
13C PLM 98% OtherPLM 2% CelluloseGreyCinderblock - Grey - HA(13)
Non-Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914287
14A PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -
HA(14) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914288
14B PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -
HA(14) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914289
14C PLM 99% OtherPLM 1% CelluloseGreyMortar / Cinderblock - Grey -
HA(14) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914290
15A PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914291
15B PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914292
15C PLM 98% OtherPLM 2% CelluloseGreyConcrete / Porch - Grey - HA(15)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/05/2026
PLM None Detected 1914293
16A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(16) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914294
16B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(16) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914295
16C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(16) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14627 Burgess, Detroit, MI 48223
ETL Job :
Client Project :
293120
293120
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
07/30/2026
07/31/2026
Date Collected :
Date Received :
PLM None Detected 1914296
17A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(17) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914297
17B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(17) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914298
17C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Driveway - Grey -
HA(17) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914299
18A PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914300
18B PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)
Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
PLM None Detected 1914301
18C PLM 100% OtherPLM Trace CelluloseGreyCaulk / Exterior - Grey - HA(18)
Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/05/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM).