INF-REL_pump_Flowserve_Vert_Turb_pump_data_0001.pdf
PDF 33 KB Posted
- Attached to
- EC - LEADVILLE REPLACE INFLUENT PUMP Federal contract opportunity
- Solicitation number
- 140R6024Q0100
About this file
This document is a hydraulic datasheet and construction datasheet for a vertical turbine pump manufactured by Flowserve. The pump is a 12EHL model with 2 stages, capable of 1125 USgpm at 80 ft of head. Key details include the pump construction, materials, dimensions, weights, testing requirements, and driver information.
The related federal contract opportunity is a solicitation for the replacement of Influent Pump #1 at the Leadville Mine Drainage Tunnel Water Treatment Plant, owned and operated by the Bureau of Reclamation. This is a total small business set-aside using NAICS code 333914. Responses are due by August 26, 2024 and should be submitted to Ana Fife at afife@usbr.gov.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140R6024Q0100_Amd_0003.pdf | ||
| Leadville_Pump_Q_As_-_22_August_2024_0003.pdf | ||
| Leadville_Pump_Q_As_-_19__August_2024_0002.pdf | ||
| Sol_140R6024Q0100_Amd_0002.pdf | ||
| Sol_140R6024Q0100_Amd_0001.pdf | ||
| INF-REL_Pumps_Specs_Original_1990_0001.pdf | ||
| Combined_Synopsis_Solicitation_140R6024Q0100_-_13_August_2024.pdf | ||
| Leadville_Influent_Pump_Replacement_SOW.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WinPROS+ V3.3.3
0 400 800 1200 1600
Capacity - USgpm
H ea d
- f t
E ffi ci en cy
Bowl efficiency
NPSHr
N P
S H r -ft
MCSF
9.33 in Maximum
9.21 in Rated
8.44 in Minimum
P ow er hp
Bowl power
Bowl head of 99.1 ft corresponds with 80.0 ft head at discharge flange adjusted for elevation and friction losses.
Bowl performance shown below is corrected for materials, viscosity and construction.
Customer : Canyon Systems Pump size & type : 12EHL Item number : Replacement Based on curve no. : EC-2655 Service : Number of stages : 2 Vendor reference : 2566-00055 Capacity : 1125.0 USgpm Specific gravity : 1.000 Date : November 4, 2010 Head : 80.00 ft Pump speed : 1770 rpm
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS, CAPACITY, HEAD, AND EFFICIENCY.
Hydraulic Datasheet
1.0 cSt
Hydraulic selection : No specification Construction : No specification Test tolerance : Hydraulic Institute Level A Driver Sizing : Max Power (SO to EOC) with SF
Customer : Canyon Systems Pump / Stages : 12EHL / 2 Customer reference : Based on curve no. : EC-2655 Item number : Replacement Vendor reference : 2566-00055 Service : Date : November 4, 2010
Operating Conditions Materials / Specification
Capacity : 1125.0 USgpm Material column code : B30 Water Capacity (CQ=1.00) : - Pump specification :
Normal capacity : - Other Requirements Total Developed Head : 80.00 ft Water head (CH=1.00) : - NPSH available (NPSHa) : 33.4 ft NPSHa less NPSH margin : - Maximum suction pressure : 0.0 psig
Liquid
Liquid type : Water Liquid description :
Temperature : 60 °F Specific gravity / Viscosity : 1.000 /
Performance
Hydraulic power : 27.9 hp Impeller diameter Pump speed : 1770 rpm Rated : 9.21 in Efficiency (CE=1.00) : 81.1 % Maximum : 9.33 in NPSH required (NPSHr) : 11.5 ft Minimum : 8.44 in Rated power : 34.4 hp Suction specific speed : 9660 US units Maximum power : 34.4 hp Minimum continuous flow : 630.3 USgpm Driver power : 40.0 hp / 29.8 kW Maximum head @ rated dia : 178.4 ft Casing working pressure : 77.2 psig Flow at BEP : 1069.9 USgpm (based on shut off @ cut dia) Flow as % of BEP : 105.2 % Maximum allowable : 69.4 psig Efficiency at normal flow : - Bowl & column hydrotest : 96.6 psig Impeller dia ratio (rated/max) : 98.7 % Minimum submergence : 24.00 in Head rise to shut off : 80.1 % Pump thrust at rated flow : 866.9 lbf Total head ratio (rated/max) : 95.1 %
0 400 800 1200 1600
Capacity - USgpm
H ea d
- f t
E ffi ci en cy
Bowl efficiency
NPSHr
N P
S H r -ft
MCSF
9.33 in Maximum
9.21 in Rated
8.44 in Minimum
Po w er hp
Bowl power
Bowl head of 99.1 ft corresponds with 80.0 ft head at discharge flange adjusted for elevation and friction losses.
Bowl performance shown below is corrected for materials, viscosity and construction.
CURVES ARE APPROXIMATE, PUMP IS GUARANTEED FOR ONE SET OF CONDITIONS, CAPACITY, HEAD, AND EFFICIENCY.
Customer : Canyon Systems Customer reference :
Item number : Replacement Service :
Pump / Stages : 12EHL / 2 Based on curve no. : EC-2655 Vendor reference : 2566-00055 Date : November 4, 2010
Construction
Bowl construction / lined : Flanged / Lined bowls Impeller type : Enclosed Impeller fastening : Colleted Suction strainer : Basket Column construction : Threaded Column flange spec'n : Taneytown Specification Column dia (nominal) : 8.00 in Column pipe length : 16.25 ft Column section length : 120.00 in Lineshaft brg spacing : 120.00 in Lineshaft diameter : 1.00 in Lineshaft coupling type : Threaded coupling Lineshaft bearings, qty : 2 Lineshaft construction : Open Lineshaft lubrication : Pumpage Enclosing tube diameter : N/A Disch size/rating/face : 8 inch / 125# ANSI / FF Pump/driver coupling : 3 "W" - Cast Above grade Discharge
Materials
Bowl : Cast iron (A48 CL30) Impeller : Bronze Bowl bearing : Bronze (C84400) Bowl shaft : 416SS (A582 Gr 416) Bowl wear ring : None supplied Impeller wear ring : None supplied Suction strainer Column : Steel A53 Type E GrB Lineshaft : Carbon steel Enclosing tube Bearing retainer Lineshaft bearing : Rubber (Buna-N) Lineshaft sleeve Discharge head : Cast iron (A48 CL30) Head shaft Support plate : None supplied
Weights (Approx.)
Complete pump : - Mounting plate : - Driver(nett) : 634.9 lb
Testing
Hydrostatic test : None Performance test : None NPSH test : None
Notes
Discharge flange is designed only to bolt up to an ANSI 125# flange but is not fully ANSI compliant.
Driver Information
Manufacturer : FPD choice Power / SF (Req' / Act') : 40.0 hp / 29.8 kW 1.15 / 1.15 Vertical shaft type : Hollow Hollow shaft coupling Driver Type : - Frame size / Base dia : 324 Enclosure : WP-1 Duty type Efficiency type Hazardous area class : - Explosion 'T' rating : - Volts / Phase / Hz : 230/460 /3/ 60 Amps-full load/locked rotor : - / - Motor starting : Direct on line (DOL) Insulation : - Temperature rise : - Bearings / Lubrication : - / - Motor mounted by : Customer Thrust rating down/up : - / -
Seal Information
Arrangement : Packed Box Size : - Manufacturer / Type : - / - Material code (Man'f/API) : Graphfiberglass / - Gland material : Cast iron Auxiliary seal device : - Seal flush plan : None Seal flush construction : - -
Paint and Package
Pump paint : - Support plate paint : - Shipment type : -
Additional Information
Pit / sump depth : 20.17 ft surface to brg hub/strainer) : 20.00 ft Available well diameter : 100.00 in Max dia below mtg surface : 15.50 in
Pump length (TPL)
Construction Datasheet
12.50
9.00
15.50
24.00
15.50
8.00
240.00 0.50
0.88
23.50
1.13 21.25
Top V iew
N ot to scale
D iam eter
M inim um subm ergence required
D iam eter, 4 holes at 90° on D iam eter bolt circle
" - 125# FF A
N
S I
D ischarge flange
M axim um diam eter
Customer : Canyon Systems Item number : Replacement Service :
Vendor reference : 2566-00055
Date : November 4, 2010 Pump size & type : 12EHL Pump speed / Stages : 1770 rpm 2
Drawing number
Rev. A 324 Driver power / Frame : 40.0 hp / 29.8 kW
Volts / Phase / Hz : 230/460
Full Page GA Drawing
Certified by / Date :
Customer PO # :
Flow / Head : 1125.0 USgpm 80.00 ft/
/3 60
Seal type : - Seal flush plan : None
All dimensions are in inches unless otherwise specified
WinPROS+ V3.3.3Copyright © 2004 Flowserve. All rights reserved
File details come from the government source that posted it. Updated .