Fire_Suppression_System_0002.pptx

PPTX presentation 9 MB Posted

Attached to
Fire suppression systems maintenance, monitoring
Solicitation number
140R3023Q0057
Issued by

About this file

This PowerPoint presentation outlines the locations and components of an existing fire suppression system across multiple buildings for a federal agency. The related solicitation seeks maintenance and monitoring services for the fire suppression systems. Key locations covered by the existing system include administrative areas on three floors, an annex building, several numbered buildings for training, security, shops, and laboratories, as well as a Colorado Street building. The solicitation was issued by the Department of the Interior Bureau of Reclamation as opportunity number 140R3023Q0057 for fire suppression system maintenance and monitoring services. Response and award dates or pricing terms are not specified in the files provided.

View the file

Other files

File Type Posted
140R3023Q0057_Q_A_2-7_0004.pdf PDF
Sol_140R3023Q0057_Amd_0004.pdf PDF
Attachment_4_LCB_Maps_0004.pdf PDF
Sol_140R3023Q0057_Amd_0003.pdf PDF
June_2023_reports_0003.pdf PDF
140R3023Q0057_Q_A_2-6_0003.pdf PDF
Attachment_4_LCB_Maps_0002.pdf PDF
140R3023Q0057_Q_A_2-5_0002.pdf PDF
Attachment_2_Price_Schedule_0002.xlsx XLSX spreadsheet
Sol_140R3023Q0057_Amd_0002.pdf PDF
Sol_140R3023Q0057_Amd_0001.pdf PDF
Attachment_2_Price_Schedule.xlsx XLSX spreadsheet
Sol_140R3023Q0057.pdf PDF
Attachment_1_Fire_Suppression_System_PWS.docx DOCX document
Attachment_3_Wage_Determination.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fire Suppression System

M – Main Panel A – Annunciator Panel P – Power System D – Dry System R - Riser

Admin First Floor (100) P

P R

Admin Second Floor (200) A

Admin Third Floor (300)

Admin Bunker Located in Comm Room D M P P

D

P

M

A

Annex BLDG

Annex Attic

BLDG 100 (Training)

R

P

A

BLDG 100 (BUNKER)

D

D

BLDG 200 First Floor Located in Security P A R

P

BLDG 200 Second Floor

BLDG 500

R A

A

BLDG 700

BLDG 1400 First Floor

D R A M P D

BLDG 1400 Second Floor

BLDG 1300 (MSCP)

D

BLDG 1100 (Fish Shop)

BLDG 900 (Boat Shop)

P

BLDG 1200 (Shop)

P R

M&P

BLDG 1000 (Lab)

Colorado St Building

P D D

M&P image1.png image2.jpeg image3.jpeg image4.png image5.jpeg image6.png image7.jpeg image8.png image9.jpeg image10.jpeg image11.jpeg image12.jpeg image13.PNG image14.jpeg image15.jpeg image16.jpeg image17.PNG image18.jpeg image19.jpeg image20.jpeg image21.jpeg image22.jpeg image23.PNG image24.jpeg image25.jpeg image26.jpeg image27.PNG image28.PNG image29.jpeg image30.jpeg image31.jpeg image32.PNG image33.jpeg image34.PNG image35.jpeg image36.jpeg image37.jpeg image38.jpeg image39.jpeg image40.jpeg image41.PNG image42.jpeg image43.PNG image44.jpeg image45.jpeg image46.PNG image47.jpeg image48.png image49.PNG image50.jpeg image51.jpeg image52.PNG image53.jpeg image54.jpeg image55.PNG image56.jpeg image57.png image58.jpeg image59.jpeg image60.jpeg

File details come from the government source that posted it. Updated .