This document is a laboratory asbestos analysis report from Mountain Laboratories for bulk samples submitted by the U.S. Bureau of Reclamation (USBR) - California on February 7, 2025. The analysis was performed for the Shasta Maintenance Center External Sample Project (Project #1) at 16349 Shasta Dam Boulevard, Shasta Lake, CA 96019. The testing method employed was 40 CFR, Part 763, Subpart E, Appendix E using Polarized Light Microscopy (PLM) supplemented by Dispersion Staining (PLM/DS). Mountain Laboratories holds NVLAP accreditation (Lab Code 101890-0) and is located in Spokane Valley, WA.
The report documents analysis results for 69 bulk samples (plus three sub-samples) collected from the Shasta Maintenance Center. Of the samples analyzed, asbestos was detected in 11 samples: samples 6, 7, 10, 11, 30, 32, 33, 34, 41, and 42 contained chrysotile asbestos at 3-5% concentration in gray layers, while sample 6 also showed 3-5% chrysotile. The remaining 58 samples tested negative for asbestos (N.D. - Not Detected). All samples were treated through teasing, crushing, and/or heating processes. The report includes detailed composition data for each sample, noting the presence of non-fibrous materials such as quartz, paint, aggregate, and other mineral content. Chain of custody documentation is provided, with all samples received and analyzed on February 7, 2025 by Laboratory Manager Heidi L. Porret. Mountain Laboratories disclaims responsibility for sample procurement and notes that negative or minimal PLM results should be confirmed with SEM or TEM analysis for greater certainty.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140R2026Q0010_Amd_0001.pdf | ||
| Sol_140R2026Q0010.pdf | ||
| C05_04_140R2026Q0010_-_Solicitation_SRF_Bldg_Asbestos_Abatement.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9922 East Montgomery Suite 13 TESTING
Spokane Valley, WA 99206 NVLAP LAB CODE 101890-0
(509) 922-1365 ● Fax (509) 922-1380
Polarized Light Microscopy, NVLAP Accreditation
February 7, 2025
USBR-California Project Name: Shasta Maintenance Center External Sample Project
Kelly DeLange Project #: 1
16349 Shasta Dam Boulevard
Shasta Lake, CA 96019
Dear Mr. DeLange, The enclosed report details results for the analysis of the bulk sample(s) submitted to Mountain
Laboratories on February 7, 2025. Sample analysis was performed to determine asbestos type and content using Polarized Light Microscopy, supplemented by Dispersion Staining (PLM/DS).
This report includes a summary of the analytical results and chain of custody. Analytical results are only reflective of the samples, which were tested and presented in this report. Mountain Laboratories limits warranty to proper analysis methods and takes no responsibility for sample procurement.
It has been our pleasure providing you with these analytical services. If you have any questions regarding this report, please do not hesitate to call us at (509) 922-1365.
Sincerely, Heidi L. Porret
Laboratory Manager
Mountain Laboratories
Mountain Laboratories NW, Inc.
Enclosure: 5084.4116.4184H
MOUNTAIN LABORATORIES
BULK SAMPLE ANALYSIS FOR ASBESTOS
Test Method: 40 CFR, Part 763, Subpart E, Appendix E Customer #: 5084
Laboratory No. B25-4116 B25-4117 B25-4118
Sample ID No. 1 2 3
Sample Description N/S N/S N/S
Sample Treatment Teased/Heated Teased/Heated Teased/Heated
Homogeneous Yes Yes Yes
Layered No No No
Fibrous No No No
Sample Color Gold/Off White Yellow/Gray Gray/Tan
Brown
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Non-Fibrous Material Other 100% Other 100% Other 100%
Date Analyzed: February 7, 2025 Analyzed By: Heidi L. Porret
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written approval by Mountain Laboratories. Soil/Dust samples are not covered under NVLAP Accreditation.
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4119 B25-4120 B25-4121
Sample ID No. 4 5 6
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated Teased
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No Yes Yes
Sample Color Beige/White Gray/Pale Yellow Pale Green/Brown
Gray
Asbestos Present No No Yes
Asbestos Type and
Percentage
N.D. Gray Layer N.D.
Pale Yellow Layer N.D.
Gray Layer
Chrysotile 3-5%
Total % Asbestos None None 3-5%
Other Fibrous Material
In Sample
Gray Layer:
Cellulose 35%
Synthetic 5%
Glass Fibers 3%
Non-Fibrous Material
Quartz 15%
Other 84%
Paint <1%
Gray Layer:
Other 60%
Pale Yellow Layer:
Other 100%
Other 92-94%
Paint not analyzed.
Thin Layer.
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4122 B25-4123 B25-4124
Sample ID No. 7 8 9
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated Teased/Heated
Teased/Crushed
Heated
Homogeneous No Yes No
Layered Yes No Yes
Fibrous Yes No No
Sample Color Pale Green/Brown
Gray Brown/Beige
Pale Green/Gray
Tan
Asbestos Present Yes No No
Asbestos Type and
Percentage
Gray Layer
Chrysotile 3-5%
N.D. N.D.
Total % Asbestos 3-5% None None
Other Fibrous Material
In Sample
Glass Fibers 3%
Non-Fibrous Material
Other 92-94%
Paint not analyzed.
Thin Layer.
Other 100% Quartz 15%
Other 75%
Aggregate 5%
Paint 5%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4125 B25-4126 B25-4127
Sample ID No. 10 11 12
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated Teased/Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes Yes No
Sample Color Pale Green/Brown
Gray
Pale Green/Brown
Gray
Pale Green/Beige
Brown
Asbestos Present Yes Yes No
Asbestos Type and
Percentage
Gray Layer
Chrysotile 3-5%
Gray Layer
Chrysotile 3-5%
N.D.
Total % Asbestos 3-5% 3-5% None
Other Fibrous Material
In Sample
Glass Fibers 3% Glass Fibers 3%
Non-Fibrous Material
Other 92-94%
Paint not analyzed.
Thin Layer.
Other 92-94%
Paint not analyzed.
Other 100%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4128 B25-4129 B25-4130
Sample ID No. 13 14 15
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige White/Gray/Beige
Asbestos Present No No No
Asbestos Type and
N.D. N.D. White Layer N.D.
Gray Layer N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Wood <1%
Non-Fibrous Material
Quartz 10%
Other 29%
Aggregate 55%
Paint 5%
Quartz 5%
Other 24%
Aggregate 70%
Paint <1%
White Layer:
Quartz 20%
Other 75%
Quartz 65%
Other 34%
Paint <1%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4131 B25-4132 B25-4133
Sample ID No. 16 17 18
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated Teased/Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Beige
Gray
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Non-Fibrous Material
Quartz 20%
Other 64%
Aggregate 15%
Paint <1%
Other 100% Quartz 20%
Other 75%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4134 B25-101496 B25-4135
Sample ID No. 19 19-A 20
Sample Description N/S Sub Sample of 19
Top Layer N/S
Sample Treatment Teased/Crushed
Heated Teased/Heated Teased/Crushed
Homogeneous No No Yes
Layered Yes Yes No
Fibrous No Yes No
Sample Color Pale Green/Gray
Beige Beige/Off White Brown/Tan
Asbestos Present No No No
Asbestos Type and
Percentage
Gray Layer N.D. Top Layer N.D. N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Cellulose 5%
Non-Fibrous Material
Quartz 20%
Other 75%
Paint 5%
Other 85%
Paint 10%
Aggregate 99%
Other <1%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4136 B25-4137 B25-4138
Sample ID No. 21 22 23
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated Teased/Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No Yes No
Sample Color Pale Green/Gray
Beige
Pale Green/Beige
Gray/Silver
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Synthetic 5%
Non-Fibrous Material
Quartz 20%
Other 70%
Paint 10%
Other 95% Quartz 5%
Other 90%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4139 B25-4140 B25-4141
Sample ID No. 24 25 26
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige White/Gray/Beige
Asbestos Present No No No
Asbestos Type and
Other 75%
Paint 5%
Quartz 5%
Other 65%
Aggregate 25%
Paint 5%
White Layer:
Quartz 20%
Other 75%
Quartz 40%
Other 55%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4142 B25-4143 B25-4144
Sample ID No. 27 28 29
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige White/Gray/Beige
Asbestos Present No No No
Asbestos Type and
Quartz 10%
Other 40%
Aggregate 40%
Paint 10%
Quartz 10%
Other 85%
Paint 5%
White Layer:
Quartz 25%
Other 74%
Paint <1%
Aggregate 75%
Other 25%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4145 B25-101497 B25-4146
Sample ID No. 30 30-A 31
Sample Description N/S Sub Sample of 30
Gray Layer N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes No No
Sample Color Pale Green/Brown
Gray
Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present Yes No No
Asbestos Type and
Percentage
Gray Layer
Chrysotile 3-5%
Gray Layer N.D. N.D.
Total % Asbestos 3-5% None None
Other 95-97%
Paint not analyzed.
Thin Layer.
Quartz 10%
Other 40%
Aggregate 40%
Paint 10%
Quartz 20%
Other 75%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4147 B25-101498 B25-4148
Sample ID No. 32 32-A 33
Sample Description N/S Sub Sample of 32
Gray Layer N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes No Yes
Sample Color Pale Green/Brown
Gray
Pale Green/Gray
Beige
Pale Green/Brown
Gray
Asbestos Present Yes No Yes
Asbestos Type and
Percentage
Gray Layer
Chrysotile 3-5%
Gray Layer N.D. Gray Layer
Chrysotile 3-5%
Total % Asbestos 3-5% None 3-5%
Other Fibrous Material
In Sample
Glass Fibers 3%
Non-Fibrous Material
Other 95-97%
Paint not analyzed.
Thin Layer.
Quartz 10%
Other 40%
Aggregate 40%
Paint 10%
Other 92-94%
Paint not analyzed.
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4149 B25-4150 B25-4151
Sample ID No. 34 35 36
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes Yes No
Sample Color Pale Green/Brown
Gray
Pale Green/Gray
Beige/Silver
Pale Green/Gray
Beige
Asbestos Present Yes No No
Asbestos Type and
Percentage
Gray Layer
Chrysotile 3-5%
N.D. N.D.
Total % Asbestos 3-5% None None
Other Fibrous Material
In Sample
Glass Fibers 3% Synthetic <1%
Non-Fibrous Material
Other 92-94%
Other 50%
Aggregate 20%
Paint 9%
Quartz 20%
Other 70%
Paint 10%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4152 B25-4153 B25-4154
Sample ID No. 37 38 39
Sample Description N/S N/S N/S
Sample Treatment Teased/Heated Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No Yes
Sample Color Pale Green/Beige
Gray
Pale Green/Gray
Beige
Pale Green/Gray
Beige/Silver
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Synthetic <1%
Non-Fibrous Material
Other 100% Quartz 20%
Other 70%
Paint 10%
Quartz 10%
Other 74%
Paint 15%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4155 B25-4156 B25-4157
Sample ID No. 40 41 42
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No Yes Yes
Sample Color Pale Green/Gray
Beige
Pale Green/Brown
Gray
Pale Green/Brown
Gray
Asbestos Present No Yes Yes
Asbestos Type and
Percentage
N.D. Gray Layer
Chrysotile 3-5%
Gray Layer
Chrysotile 3-5%
Total % Asbestos None 3-5% 3-5%
Other Fibrous Material
In Sample
Glass Fibers 3% Glass Fibers 5%
Non-Fibrous Material
Quartz 10%
Other 80%
Paint 10%
Other 92-94%
Other 90-92%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4158 B25-4159 B25-4160
Sample ID No. 43 44 45
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous Yes No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other 75%
Paint 15%
Quartz 20%
Other 70%
Paint 10%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4161 B25-4162 B25-4163
Sample ID No. 46 47 48
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated Teased/Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige Pale Green/Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other 70%
Paint 10%
Other 100% Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4164 B25-4165 B25-4166
Sample ID No. 49 50 51
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
Gray Layer N.D. Gray Layer N.D. N.D.
Total % Asbestos None None None
Other 15%
Aggregate 15%
Paint 60%
Quartz 10%
Other 40%
Aggregate 40%
Paint 10%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4167 B25-4168 B25-4169
Sample ID No. 52 53 54
Sample Description N/S N/S N/S
Sample Treatment Teased/Heated Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Beige Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other 100% Quartz 20%
Other 70%
Paint 10%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4170 B25-4171 B25-4172
Sample ID No. 55 56 57
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
Gray Layer N.D. N.D. N.D.
Total % Asbestos None None None
Other 40%
Aggregate 40%
Paint 10%
Quartz 20%
Other 70%
Paint 10%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4173 B25-4174 B25-4175
Sample ID No. 58 59 60
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige White/Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other 70%
Paint 10%
Quartz 20%
Other 70%
Paint 10%
Quartz 45%
Other 35%
Paint 20%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4176 B25-4177 B25-101499
Sample ID No. 61 62 62-A
Sample Description N/S N/S Sub Sample of 62
Top Layer
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No Yes No
Layered Yes No Yes
Fibrous No No Yes
Sample Color Pale Green/Gray
Beige Gray
Beige/Brown
Pale Green/Off White
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. Gray Layer N.D. Top Layer N.D.
Total % Asbestos None None None
Other Fibrous Material
In Sample
Cellulose 5%
Non-Fibrous Material
Quartz 20%
Other 70%
Paint 10%
Quartz 20%
Other 80%
Other 75%
Paint 20%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4178 B25-4179 B25-4180
Sample ID No. 63 64 65
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Gray/Beige Gray/Beige Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
Gray Layer N.D. Gray Layer N.D. N.D.
Total % Asbestos None None None
Other 64%
Aggregate 25%
Paint <1%
Quartz 10%
Other 64%
Aggregate 25%
Paint <1%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4181 B25-4182 B25-4183
Sample ID No. 66 67 68
Sample Description N/S N/S N/S
Sample Treatment Teased/Crushed
Heated
Teased/Crushed
Heated
Teased/Crushed
Heated
Homogeneous No No No
Layered Yes Yes Yes
Fibrous No No No
Sample Color Pale Green/Gray
Beige
Pale Green/Gray
Beige
Pale Green/Gray
Beige
Asbestos Present No No No
Asbestos Type and
Percentage
N.D. N.D. N.D.
Total % Asbestos None None None
Other 70%
Paint 10%
Quartz 20%
Other 70%
Paint 10%
Quartz 20%
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Laboratory No. B25-4184
Sample ID No. 69
Sample Description N/S
Sample Treatment Teased/Crushed
Heated
Homogeneous No
Layered Yes
Fibrous No
Sample Color Pale Green/Gray
Beige
Asbestos Present No
Asbestos Type and
Percentage
N.D.
Total % Asbestos None
Other 70%
Mountain Laboratories, Mountain Laboratories NW, Inc. limits warranty to proper analysis methods only and takes no responsibility for sample procurement. Mountain Laboratories, Mountain
Laboratories NW, Inc., 9922 E. Montgomery Suite #13, Spokane Washington 99206 (509) 922-1365 - Fax (509) 922-1380. PLM has been known to miss asbestos in a small percentage of samples. Thus negative or <1% PLM results should be tested with either SEM or TEM. Customer is responsible for sample separation. This report may only be reproduced in full with written
Sample results must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
File details come from the government source that posted it. Updated .