C06__Amendment_2_SOW_Update_0002.pdf
PDF 162 KB Posted
- Attached to
- NCAO Modular Indoor Shooting Range Federal contract opportunity
- Solicitation number
- 140R2025Q0048
About this file
This document is an amended Statement of Work (SOW) for a Modular Indoor Shooting Range (MISR) solicitation by the Bureau of Reclamation's Northern California Area Office. The solicitation seeks a two-lane, .308 ball munition rated, 100-yard modular indoor shooting range for the Security Response Force (SRF) at Shasta Dam, with an option to purchase a second range. Key requirements include a containerized range system with full ballistic containment, dimmable lighting, 360-degree target retrieval, HVAC with negative air pressure, HEPA filtration, seismic anchoring, and compliance with OSHA lead exposure standards and accessibility guidelines.
The contract is a firm-fixed price purchase order, with delivery set for one year after receipt of order to the Shasta Maintenance Center in Shasta Lake, California, with an optional second unit potentially delivered to Folsom Dam. The range must support live fire with 5.56mm and .223 ammunition, withstand various weather conditions, and include a control room with software and hardware for instructor monitoring. The contractor must provide a 2-hour training session, comprehensive maintenance list, and ensure all installations meet federal accessibility standards. The solicitation includes specific technical requirements for sound levels, ventilation, and range infrastructure.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140R2025Q0048_Amd_0003.pdf | ||
| C06__Amendment_3_Q-A_Document_0003.pdf | ||
| C06__Amendment_3_SOW_Update_0003.pdf | ||
| Sol_140R2025Q0048_Amd_0002.pdf | ||
| C06__Amendment_2_Q-A_Document_0002.pdf | ||
| C06__Amendment_2_Updated_Solicitation_Document_0002.pdf | ||
| Sol_140R2025Q0048_Amd_0001.pdf | ||
| Sol_140R2025Q0048.pdf | ||
| C05__Attachment_Buy_American_Act_Certificate_140R2025Q0048.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
140R2025Q0048 NCAO Modular Indoor Shooting AMENDMENT 0002 Range (MISR)
STATEMENT OF WORK
AMENDED 6/24/2025
1.0 BACKGROUND
Shasta Dam is considered a National Critical Infrastructure (NCI), and it is imperative to ensure the dam and powerplant continue to operate without interruption. Based on a Security Effective Assessment in January of 2024, the Region and NCAO leadership have determined the need for a response capable armed guard force at Shasta Dam, specifically the Security Response Force (SRF). Shasta Dam has a requirement for an indoor range for SRF personnel to conduct firearms training and qualifications year around.
2.0 OBJECTIVE
The objective of this contract is to obtain a live fire range that eliminates SRF personnel from having to travel offsite to conduct training and the ability to conduct firearms training during inclement weather.
3.0 SCOPE
The scope of work for this requirement includes:
a) Supplying the one (1) modular indoor shooting range, in accordance with the specifications identified in Section 4.0 6.0.
b) Transporting and placing the modular indoor shooting range on-site
c) Installing the modular indoor shooting range on-site in accordance with all local, state and
Federal requirements.
d) Providing one, 2-hour training session to Reclamation personnel covering system maintenance, operations, and troubleshooting.
e) The option to purchase a second indoor range with the same salient characteristics and requirements listed on this statement of work (SOW). The option will expire on 01/01/2027.
4.0 TYPE OF CONTRACT
This will be a firm-fixed price purchase order.
5.0 LOCATION – The location of delivery for primary unit will be as follows:
Bureau of Reclamation
Shasta Maintenance Center 16349 Shasta Dam Blvd Shasta Lake, CA 96022-9019
The exact coordinates of the proposed placement are:
40°42’54.45” N 122°25’46.92” W elev. 630 ft
Optional Unit (if exercised) location:
Folsom Dam Bureau of Reclamation 7794 Folsom Dam Road-Receiving Folsom, CA 95630
6.0 REQUIREMENTS
The contractor shall provide a modular containerized build indoor shooting range that has a two
(2) lane .308 ball munition rated 100-yard modular, transportable, small arms training range. The modular range must equal a 100-yard shooting distance not to exceed 360’ in length and must be capable of supporting live fire with weapons up to (and including) 5.56mm and .223 ammunitions, hollow point and frangible ammunition for weapon training up to 3240 FPS and/or 1286 ft. lbs.
The modular range system shall be designed to retain full structural integrity to support all ballistic treatments, ventilation equipment, and accessories. The system must maintain 100% full ballistics (projectile & ricochets) containment to allow for placement at a zero-surface danger zone (SDZ) site creating a safe shooting environment. Containment integrity shall be coordinated with the design and installation of ventilation systems, environmental control systems, noise reduction controls, entry/exit controls and general construction. The modular containerized range system shall be designed and constructed with .308 caliber rated ballistic interior walls, ceiling, and must have two (2) steel vertical bullet traps to eliminate the possibility of projectiles from ricocheting toward the shooting stalls and shooters.
a) The modular containerized range system shall be pre-engineered to allow for assembly and full operation in its original design, possess the capability to be disassembled, transported and reassembled as a complete fully operational two (2) lane modular range system at different locations utilizing standard construction methods and commercial transportation.
The range system must be able to withstand numerous weather conditions to include but not limited to rain, snow, wind and prolonged exposure to sun including heat of approximately 115°F for sustained periods.
b) The modular range system shall be designed with the ability to control dimmable lighting during live fire operations to allow for simulation of nighttime firing and with a turning, self-propelled 360-degree target retrieval system able to be controlled from a master control panel and at each lane of fire. The MISR must have a 110/220v AC power connections setup for a training simulator to be installed at a later date.
c) The modular range system shall be designed and constructed in a manner that allows for the SRF firearm instructor to have access to control panels of all range operations from a single point while maintaining vision of each lane of fire. Within the modular indoor range there will be a control room and all required IT-related software and hardware, allowing the instructor to view the actions of the students on the firing line. The software and hardware will allow for control all training equipment e.g. lights, targets, temperature, ventilation, sound etc. and allow the instructor to communicate with and hear the students on the firing line. The modular indoor range will include a wireless tablet and ability to charge the tablet allowing the instructor the mobility to control the target system at the firing line. The contractor will provide one (1), training class, or up to 2hrs of training, on how to operate the control room technology and equipment and mobile tablet. This includes basic operation, creating and uploading new training courses of fire, and system/equipment troubleshooting.
d) The modular range system must be equipped with an HVAC system that is permanently fixed to the system, in an area that will not impede the moveability of the range. The HVAC must be capable of maintaining a consistent interior temperature of 72 degrees Fahrenheit regardless of the exterior temperature outside. The HVAC system must maintain constant air flow and a negative pressure to ensure that lead, smoke and airborne particulate are moved away from the shooter. All air must pass through a high efficiency particulate air (HEPA) filter rack before it is exhausted outside of the range system.
e) The flooring from the shooting stalls and everything behind will be painted black. The stalls must have a swing down shooter’s tray, and a collapsible shooting barricade.
f) Sound test results shall be submitted prior to award of contract. Standard that the contractor should meet includes using a 5.56mm and .223 rifle. The sound when using both at 25 feet shall be under 100db, 50 feet under 90db, 75 feet under 80 db and 100 feet should be under 70db. The test results submitted are required to be from a like model or design constructed with the same materials as the modular indoor shooting range specified in the SOW.
g) The contractor shall be responsible for removing all debris and surplus chemicals or liquids used during the installation.
h) The contractor will provide a comprehensive list of all maintenance that needs to be completed on the infrastructure and operating system. This includes but is not limited to routine maintenance (on a monthly and yearly basis) as well as preventative maintenance (on a monthly and yearly basis).
i) The contractor shall be responsible for all labor, parts and materials necessary for installation. No Government furnished property will be provided.
j) Desired MISR interior height: no less than 84” excluding the required equipment hanging from the ceiling.
k) Desired MISR width: no less than 8’.
7.0 DELIVERY AND SET UP
All deliverable items shall be made one-year after receipt of order (ARO)
F.O.B Delivery Terms. The contractor shall include all shipping costs in the order.
The transportation and delivery of the modular indoor shooting range shall be in accordance with the local and state requirements.
The contractor shall provide all the materials required to set up the modular indoor shooting range on site. The modular indoor shooting range is to be leveled and supported by steel piers with pressure treated wood pads. Seismic anchoring is also required in accordance with local code.
The Government shall be responsible for making connections to the modular indoor shooting range to provide power and communications. The Government will provide 150 amp/120/208 V / 3-phase / 60Hz power. The Government will provide communications for future phone use.
Contractor shall notify Reclamation no less than two weeks prior to delivery to arrange for access to site. The contractor will arrange for delivery to the Warehouse location within the working hours of 0600-1600 Monday through Friday.
8.0 ADMINISTRATIVE INFORMATION
a) Recognized Holidays – The Contractor is not required to work on the following Federal
Holidays:
New Year’s Day Birthday of Martin Luther King Jr.
President’s Day Memorial Day Juneteenth National Independence Day Independence Day Labor Day Columbus Day Veteran’s Day Thanksgiving Day Christmas Eve/Christmas Day
*If any new Federal Holiday is declared, it will be added to this list of Recognized Federal Holidays and the Contractor will not be required to perform work on that day.
9.0 APPLICABLE STANDARDS, ORGANIZATIONS, AND REFERENCES
The SRF must comply with OSHA 29 CFR 1910.1025 (Lead Standard) in protecting its employees from hazards associated with lead exposure. The range system must have a ventilation system designed to supply and exhaust air flow to ensure that lead, smoke, and airborne particles are moved away from the shooter. The ventilation system must utilize HEPA filters to prevent lead from entering the outside environment. The filtered exhaust area must be at/or behind the bullet trap.
All paints must comply with the USDA Biopreferred Program standards at:
https://www.biopreferred.gov/BioPreferred/faces/pages/ProductCategories.xhtml
All lighting must comply with Energy Star or Federal Energy Management Program (FEMP) at: https://www.energystar.gov/products
The Architectural Barriers Act (ABA) Standards, 2015 https://www.access-board.gov/files/aba/ABAstandards.pdf
The contractor shall design and manufacture the product to ensure accessibility as required by law for persons with disabilities in accordance with the Architectural Barriers Act of 1968 (82.
Stat. 718), as amended (42 U.S.C. 4151 et seq.) and Section 504 of the Rehabilitation Act of 1973, as amended (29 U.S.C. 794).
Specific requirements are set forth in the Americans with Disabilities Act/Architectural Barriers Act Accessibility Guidelines: ABA Chapter 1 (Application & Administration); Chapter 2 (Scoping Requirements); Chapters 3-10 (Technical Requirements), commonly referred to as ABAAS, and shall be used by the Contractor to ensure requirements set forth in ABAAS. It is the sole responsibility of the Contractor to determine beforehand how to address tolerances to ensure that the finished products comply with Federal standards. Should the finished product fail to comply, it shall be the responsibility of the Contractor, at its sole expense, to make any adjustments necessary to bring the deficient components into compliance.
Specifically, the technical requirements under ABAAS Chapter 3 Section 303 requires where change in level are permitted in floor or ground surfaces, they shall comply with:
a) 303.2 Vertical: Changes in level of 1/4” high maximum shall be permitted to be vertical. or
b) 303.3 Beveled: Changes in level between 1/4” high minimum and 1/2” maximum shall be beveled with a slope not steeper than 1:2 (50% bevel).
**END OF STATEMENT OF WORK**