B08_Attachment_2__FLAGPOLES_SCHEMATIC.pdf

PDF 1 MB Posted

Attached to
REPLACE 2ND DIVISION FLAGPOLES
Solicitation number
140P8526Q0037
Issued by

About this file

This is an architectural/engineering drawing set for the National Park Service, National Capital Region, specifically depicting the 2nd Division Flagpoles feature at Presidents Park in Ellipse, Washington, D.C. The project is identified as PRPA-***** and was created by LAZENBY, dated 2026-01-29, with verification by WAGMAN.

The drawings provide detailed site and construction plans for the 2nd Division Memorial flagpole installation. Sheet 1 presents an overall site plan at a scale of 1" = 40' showing the flagpole location relative to Constitution Avenue and surrounding landscape features, including vegetation represented by green circles and utility lines in blue. Sheet 2 provides a detailed plan view at a scale of 1" = 10' showing the memorial structure, planting locations (American Holly trees marked with elevations), utility routing information, and construction notes. Key technical specifications include provisions for American Holly plantings at various elevations (ranging from 220-223 feet), steel edging, site lighting with both 1/2" PVC and W6 PVC pathway routing, and flagpole power access notes indicating that power for flagpole 1 may be pulled from a handhole using existing 1 1/2" PVC pathway to maximum extent possible, with alternative routing along existing PVC if necessary. Power for flagpole 2 may be accessed from either light fixture. The drawings indicate this is Sheet 1 of X and Sheet 2 of X, suggesting additional documentation exists for this project.

View the file

Other files

File Type Posted
Sol_140P8526Q0037_Amd_0001.pdf PDF
B08_Attachment_4_Q_As_0001.pdf PDF
B08_Attachment_1_SOW.pdf PDF
Sol_140P8526Q0037.pdf PDF
B08_Attachment_3_WD_DC20260002_Rev_2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

vlazenby Text Box

1 OF X

vlazenby Rectangle vlazenby Rectangle vlazenby

SEE SHEET 2

vlazenby

2 OF X

vlazenby Rectangle jgibbons Cloud+ jgibbons Cloud+ Power for flagpole 1 may be pulled from handhole. Utilize existing 1 1/2" PVC pathway to maximum extent possible. Otherwise route new pathway along same route as existing PVC.

jgibbons Cloud+ jgibbons Cloud+ Power for flagpole 2 may be accessed from either light.

jgibbons Cloud jgibbons Line

File details come from the government source that posted it. Updated .