B08_Attachment_2_Drawings_Amendment_2_0002.pdf

PDF 4 MB Posted

Attached to
Rehabilitate Wolf Creek Water System, NPS-REDW
Solicitation number
140P8424R0005
Issued by

About this file

This document contains drawings and plans for the rehabilitation of the Wolf Creek Water System in Redwood National and State Parks, Del Norte County, California. The project involves replacing the existing 4-inch water main from the campground to Station 13+13, as well as modifying the existing water treatment plant under the base bid. Bid Option 1 includes replacing the remaining water distribution system from Station 13+13 through the rest of the Wolf Creek area, including new service connections.

Key details include:

  • The project requires horizontal directional drilling (HDD) from Station 0+00 to 13+13
  • Staging areas and potential drilling pit locations are identified
  • Drawings provide details on the water main alignment, stream crossing, water treatment plant modifications, and water system details such as thrust blocks and valve boxes
  • The solicitation number is 140P8424R0005, issued by the Department of the Interior National Park Service Pacific West Region

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBSHEET

SHEET

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

G-001

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

TI

TL

E

SH

EE

T

SHEET INDEX

DESCRIPTIONSHEET

G-001 G-002

TITLE SHEET

GENERAL PROJECT INFORMATION

STATE PARKS

PARK HEADQUARTERS

TRAIL

UNPAVED ROAD

VISITOR CENTER

MAJOR RIVER OR CREEK

PAVED ROAD

PARK BOUNDARY

LEGEND

U.S DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

PACIFIC WEST REGION

DEL NORTE COUNTY, CALIFORNIA

C-001 PROJECT OVERVIEW

C-002 WATER MAIN PLAN

C-003 STREAM CROSSING DETAILS

C-004 WATER PLANT PLAN

C-005 WATER SYSTEM DETAILS

C-006 DETAILS

C-007-010 BID OPTION 1 PLAN & DETAILS

/1

7/

A M

E N

D M

E N

T

HUMBOLDT COUNTY, CALIFORNIA

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

G-002

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

G

EN

ER

AL

P R

O

JE

C T

IN

FO

R M

AT

IO

N

1. IN GENERAL, EXISTING STRUCTURES, EQUIPMENT, AND FACILITIES ARE SHOWN

AS LIGHT LINE WEIGHTS OR SCREENED BACKGROUND. NEW STRUCTURES,

EQUIPMENT, AND FACILITIES ARE SHOWN IN HEAVY LINE WEIGHTS. OTHER

DISCIPLINES MAY SCREEN NEW STRUCTURES TO SHOW THEIR INFORMATION.

2. ALL EXISTING TREES TO REMAIN UNLESS OTHERWISE SPECIFIED.

3. ALL DISTURBED ASPHALT, GRASS, DRAINAGE PATTERNS, ROADSIDE DITCHES,

TRAILS AND GRADE SHALL BE RESTORED TO ITS ORIGINAL CONDITION OR AS

CALLED FOR ON THE CONTRACT DOCUMENTS, WHICHEVER IS MORE STRINGENT.

4. SCHEDULE ALL EXISTING UTILITY LINE SHUTDOWNS WITH THE CONTRACTING

OFFICER.

5. ALL CONNECTIONS TO EXISTING MAINS SHALL BE MADE BY THE CONTRACTOR

ONLY AFTER THE PROPOSED CONNECTION PROCEDURE AND WORK SCHEDULE

HAS BEEN REVIEWED AND APPROVED BY THE CONTRACTING OFFICER. THE

CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST TO THE CONTRACTING

OFFICER A MINIMUM OF FIVE (5) WORKING DAYS PRIOR TO SCHEDULING ANY

CONNECTIONS. THE REQUEST SHALL OUTLINE THE FOLLOWING:

A. POINTS OF CONNECTION, FITTINGS TO BE USED, AND METHOD OF FLUSHING

AND DISINFECTION,

B. ESTIMATED CONSTRUCTION TIME FOR THE CONNECTION, AND DISINFECTION.

AFTER RECEIPT OF THE WRITTEN REQUEST THE CONTRACTING OFFICER SHALL

REVIEW THE SUBMITTAL AND GIVE AN APPROVAL OR REJECTION OF THE

REQUEST WITHIN THREE (3) WORKING DAYS. IF THE REQUEST IS REJECTED, THE

CONTRACTOR SHALL RESUBMIT THE REQUEST, MAKING MODIFICATIONS IN A

MANNER ACCEPTABLE TO THE CONTRACTING OFFICER. ALL CONNECTIONS SHALL

ONLY BE MADE ON AGREED UPON DATE AND TIME. IF THE CONTRACTOR DOES

NOT INITIATE AND COMPLETE THE CONNECTION WORK IN THE AGREED UPON

MANNER, THE CONTRACTOR SHALL BE REQUIRED TO RESCHEDULE THE

CONNECTION BY FOLLOWING THE PROCEDURE OUTLINED ABOVE. MAINS SHALL

NOT BE PLACED IN SERVICE UNTIL CLEARANCE IS GRANTED BY THE

CONTRACTING OFFICER.

6. PIPE AND JOINT DEFLECTIONS PERMITTED WITHIN RANGE OF MANUFACTURER'S

ALLOWANCES.

7. ALL COSTS ASSOCIATED WITH REPAIR AND/OR REPLACEMENT OF EXISTING

UTILITIES, DUE TO CONTRACTOR'S ACTIVITIES, SHALL BE THE RESPONSIBILITY OF

THE CONTRACTOR.

8. ANY KNOWN SEWERS, WATER MAINS, CONDUITS, ELECTRIC CABLES, AND OTHER

UNDERGROUND/OVERHEAD ITEMS ARE SHOWN ON THE DRAWINGS ONLY TO THE

EXTENT SUCH INFORMATION HAS BEEN MADE AVAILABLE OR DISCOVERED BY

THE ENGINEER. IT IS EXPECTED THAT THERE MAY BE DISCREPANCIES AND

OMISSIONS IN THE LOCATION AND QUANTITIES OF EXISTING UTILITIES AND

STRUCTURES SHOWN. THIS INFORMATION IS SHOWN FOR THE CONVENIENCE OF

THE CONTRACTOR BUT IS NOT GUARANTEED TO BE EITHER CORRECT OR

COMPLETE AND ALL RESPONSIBILITY FOR THE ACCURACY AND COMPLETENESS

THEREOF IS EXPRESSLY DISCLAIMED. THE CONTRACTOR SHALL MAKE SUCH

INVESTIGATION AS NECESSARY TO VERIFY ITS CORRECTNESS AND

COMPLETENESS.

9. FIELD LOCATE ALL EXISTING UTILITIES, BURIED PIPING, INCLUDING WATER

SERVICE CONNECTIONS, AND ALL OTHER SURFACE AND SUB-SURFACE

FEATURES PRIOR TO CONSTRUCTION. ANY FEATURES DAMAGED BY

CONTRACTOR'S ACTIVITIES SHALL BE REPLACED TO PRE-CONSTRUCTION

CONDITION AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT. ANY FIELD

LOCATED EXISTING CONDITIONS IMPACTING NEW WORK SHALL BE IMMEDIATELY

BROUGHT TO THE CONTRACTING OFFICER'S ATTENTION.

10. ALL EXISTING VALVES AND EQUIPMENT SHALL ONLY BE OPERATED BY THE THE

NATIONAL PARK SERVICE.

LEGEND AND ABBREVIATIONS

FIRE HYDRANT

EXISTING SANITARY SEWER (GRAVITY)

ABANDONED LINE (VARIOUS TYPES)

EXISTING WATER

PROPOSED WATER (SIZE)

IRRIGATION LINES

UNDERGROUND ELECTRIC

EXISTING SANITARY FARCE MAIN

OVERHEAD ELECTRIC

FENCE

POWER POLE

SANITARY MANHOLE

DRAINAGE INTAKES

LIGHT POLE

EXISTING GAS

STORM SEWER

NEW WATER MAIN

1. CONTRACTOR SHALL PROVIDE A FRAC-OUT CONTINGENCY PLAN, INCLUDING MINIMUM

REQUIREMENTS PER PROJECT SPECIFICATIONS, PRIOR TO CONSTRUCTION.

2. CONTRACTOR SHALL PROVIDE MONITORING FULL TIME DURING HORIZONTAL DIRECTION

DRILLING (HDD) OPERATIONS.

1. THE BASE BID FOR THIS PROJECT INCLUDES REPLACING THE WATER MAIN FROM

CAMPGROUND TO STA. 13+13, AND MODIFYING THE EXISTING WATER PLANT.

2. BID OPTION 1 INCLUDES REPLACING THE REMAINING WATER DISTRIBUTION SYSTEM

FROM STA. 13+13 THROUGH THE REST OF THE WOLF CREEK AREA, INCLUDING NEW

SERVICE CONNECTIONS.

3. THE EXISTING SYSTEM FEEDS THE DISTRIBUTION SYSTEM BY SENDING FLOW THROUGH

THE BOOSTER STATION. FLOW THEN FLOWS BACKWARDS TO SUPPLY THE SYSTEM.

4. THE BID OPTION WOULD ELIMINATE THE REVERSE FLOW SCENARIO AND FEED THE

WOLF CREEK BUILDINGS DIRECTLY, THEREBY ELIMINATING THE UNNECESSARY LENGTH

OF PIPE.

95 10

110105

0+00

1+00

2+00

3+00

4+00

5+00

6+00

7+00

8+00

9+00

10+00

+0

+0

+0

+1

SUBSHEET

SHEET

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-001

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

PR

O

JE

C

T O

VE

R

VI

EW

2525 0 50

HORIZ.

BASE BID

CONSTRUCT NEW 4" WATER MAIN

SEE SHEET C-002

MODIFY EXISTING WATER (BOOSTER) PLANT.

BASE BID SEE SHEET C-004.

BID OPTION 1 SEE SHEET C-009.

PRAIRIE CREEK

NPS FIRE CACHE BUILDING

WOLF CREEK EDUCATION CENTER

ACCESS ROAD

NPS STAFF HOUSING

ACCESS. (CAMPGROUND LOOP ROAD)

BEGIN BID OPTION 1

REPLACE WATER MAIN &

SERVICE CONNECTIONS

(WEST OF THIS POINT)

BID OPTION 1

SEE SHEETS C-007

THROUGH C-010

105110

0+

1+

2+

3+

4+

5+

6+

7+

8+

9+

+0

11+00

12+00

13+00

13+13

SUBSHEET

SHEET

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-002

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

4040 0 80

HORIZ.

LOCATE AND CONNECT TO EXISTING

4" WATER MAIN NEAR END OF

CAMPGROUND LOOP

REMOVE EXISTING 1" OVERHEAD

WATER MAIN CROSSING. CAP ENDS

BOTH SIDES

SEE SHEET C-003

PRAIRIE CREEK

WATER MAIN ALIGNMENT GENERALLY

FOLLOWS EXISTING TRAIL

CONNECT TO EXISTING 4" WATER MAIN

EXISTING 4" WATER MAIN

TO BE ABANDONED IN PLACE.

W

AT

ER

M

AI

N

P

LA

N

LOCATE BEND ALONG

EXISTING TRAIL

POTENTIAL DRILLING PIT

(4'X4'X4')

NOTES

1. HDD IS REQUIRED FROM STA. 0+00 TO STA. 13+13

2. VEGETATION MAY BE TRIMMED ALONG ALIGNMENT AND IN STAGING AREAS

TO IMPROVE ACCESS AND AID MONITORING. HOWEVER, ALL TREES SHALL

BE PROTECTED.

3. SEE G-002 FOR FRAC-OUT CONTINGENCY PLAN NOTES.

4. CONTRACTOR PROVIDED FIELD SOIL SAMPLING INVESTIGATION CAN

INCLUDE HAND OR HANDTOOL AUGER SAMPLE COLLECTION AT STAGING

LOCATIONS INDICATED.

WATER MAIN ALIGNMENT GENERALLY

FOLLOWS EXISTING TRAIL

POTENTIAL DRILLING PIT

(4'X4'X4')

POTENTIAL DRILLING PIT

(4'X4'X4')

POTENTIAL STAGING AREA

25'X25'

POTENTIAL STAGING AREA

(25'X50')

REFERENCE FRAC-OUT CONTINGENCY

PLAN FOR ADDITIONAL MEASURES

REQUIRED AT WATER BODIES (PRAIRIE CREEK)

POTENTIAL STAGING AREA

(40'X40')

POTENTIAL STAGING AREA

(40'X40')

POTENTIAL STAGING AREA

(40'X40')

/1

7/

A M

E N

D M

E N

T

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-003

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

PROPOSED 4" WATER MAIN

GENERAL WATER MAIN PROFILE

NTS

PROPOSED 4" GATE VALVE

(BOTH SIDES) - REF SHEET C-002

FOR LOCATIONS

' M

IN

TOP OF BANK

4' M

IN

EXISTING GRADE

MARK VALVE LOCATION

W/ PERMANENT MARKER

EXISTING GRADE

4" WATER MAIN BELIEVED

TO BE PVC

4" WATER MAIN BELIEVED

TO BE PVC

TRANSITIONS TO 1"

HDPE AT CROSSING

TRANSITIONS BACK TO 4"

DOWNSTREAM OF CROSSING

1" HDPE AT ATTACHED TO CABLE

WOODEN POST

EXISTING STREAM CROSSING

NTS

UPSTREAM WOOD POST

1" HDPE PIPE ATTACHED TO CABLE

ST

R

EA

M

C R

O

SS

IN

G

D

ET

AI

LS

NOTES

1. CONTRACTOR SHALL PERFORM DEMOLITION WORK WITH MEANS AND METHODS THAT

PREVENT MATERIAL AND CREW FROM ENTERING THE STREAM.

2. FULLY DRAIN WATER LINE PRIOR TO DEMOLITION.

3. CUT EXISTING 4" LINE AT GROUND TRANSITION TO RISER.

4. CAP AND ABANDON IN PLACE EXISTING IN-GROUND LINE.

5. REMOVE OVERHEAD 1" HDPE LINE AND CABLE.

6. CUT OFF WOOD POSTS AT GROUND LEVEL.

* CONSTRUCT 12' DEEP UNDER STREAM TO

PREVENT FRAC-OUT INTO WATER BODY. ALL

OTHER SEGMENTS ONLY NEED TO BE 4' DEEP.

/1

7/

A M

E N

D M

E N

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-004

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

TREATMENT PLAN PLAN

NTS

F&I 6" TEE

F&I HYDRANT ASSEMBLY

(PAINT PURPLE)

DISCONNECT OUTLET AND

CAP TEE END

F&I 4" TEE

F&I STATE APPROVED (HIGH HAZARD FIRE CONNECTION)

REDUCED PRESSURE BACKFLOW

ASSEMBLY. BASIS OF DESIGN AMES LMF500 (MAXIUM 500)

REMOVE 2" PIPE AND ACCESSORIES BETWEEN

GATE VALVES AND RECONNECT WITH 4" LINE.

F&I 4"x6" INCREASER

CONNECT TO EXISTING PIPE

F&I 6" 90° BEND

F&I 4" GATE VALVE

PATCH HOLE IN BUILDINGREMOVE GATE VALVE AFTER TEST

NOTES

1. WORK TO THE PLANT WILL ONLY BE ALLOWED AFTER THE WATER MAIN CONSTRUCTION.

2. PRIOR TO WORKING ON THE PLANT, THE CONTRACTOR SHALL VERIFY STATIC

PRESSURE , AND CONDUCT A FLOW TEST. THE PURPOSE OF THE FLOW TEST WILL BE

TO VERIFY THAT THE MODIFIED WATER MAIN CAN DELIVER THE AMOUNT OF FLOW

REQUIRED BASED ON A 4-INCH LINE SIZE. THE FLOW TEST WILL CONFIRM THAT THERE

ARE NO OTHER RESTRICTIONS ALONG THE LINE THAT THE NPS IS NOT AWARE OF.

3. IF THE FLOW TEST FAILS, NOTIFY THE NPS IMMEDIATELY.

4. THERE IS AN EXISTING HYDRANT ASSEMBLY NEAR THE TREATMENT BUILDING THAT

WAS DAMAGED AND IS BADLY CORRODED. REPLACE THE FULL ASSEMBLY INCLUDING

THE TEE FITTING. FULLY EXCAVATE AND REMOVE SOIL WITHIN 3' OF ALL ASSEMBLY

COMPONENTS. BACKFILL WITH COMPACTED APPROVED SOIL BROUGHT IN FROM

OUTSIDE SOURCE. THE SOIL THAT WAS USED TO BACKFILL THE EXISTING ASSEMBLY

WAS FOUND TO BE BEACH SAND WHICH LED TO THE FAILURE OF THE FITTINGS DUE TO

CORROSION.

CONDUCT FLOW TEST BY DISSEMBLING

PIPE DOWNSTREAM OF 4" GATE VALVE.

REMOVE GATE VALVE AFTER TEST

W

AT

ER

P

LA

N

T

PL

AN

REPLACE HYDRANT ASSEMBLY.

SEE NOTE 4

F&I 4" GATE VALVE

F&I 4" DI PIPE

F&I 6" DI PIP

BID OPTION VARIATION

1. IF BID OPTION 1 IS EXECUTED THE CONFIGURATION

NEAR THE EXISTING PLANT WILL VARY. IF BID

OPTION 1 IS AWARDED, CONSTRUCT AS SHOWN ON

SHEET C-009

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-005

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

TEST PRESSURES AND SOIL BEARING PRESSURES, USE THE FOLLOWING EQUATION:

PRESSURE OF 2,000 psf AND A SAFETY FACTOR OF 1.5, TO COMPUTE BEARING AREAS FOR DIFFERENT

1. BEARING AREAS (TABLE 1) BASED ON TEST PRESSURE OF 150 psi, AN ALLOWABLE SOIL BEARING

BEARING AREA = (TEST PRESSURE / 150 psi) x (2,000 / SOIL BEARING PRESSURE psf) x (TABLE 1 VALUE)

3. BEARING AREA OF THRUST BLOCK SHALL NOT BE LESS THAN 1.0 SQUARE FOOT.

(HORIZONTAL BENDS & VERTICAL UPWARD BENDS)

TABLE 1 - BEARING AREA OF THRUST BLOCKS IN SQUARE FEET

HORIZONTAL BENDS AND VERTICAL UPWARD BENDS:

TEE PLUGGED ON RUN

4. IF THE DEPTH REQUIREMENT (SEE TYPICAL CROSS SECTION) CAN NOT BE ACHIEVED,

UNDISTURBEDBEDDING

1/2 TO 1 TIMES ITS WIDTH.

BLOCK HEIGHT (h) SHALL BE

LESS THAN THE PIPE DIAMETER

OF THE BLOCK (H), BUT NOT

THE TOTAL DEPTH TO THE BOTTOM

EQUAL TO OR LESS THAN 1/2

BLOCK HEIGHT (h) SHALL BE

TYPICAL CROSS SECTION

MATERIAL

DEPTH REQUIREMENT:

A

BEND

A1

A1

PLUGGED CROSS

SOIL

1A

1A

PLUGGED CROSS

A1

3. CONCRETE THRUST BLOCKING TO BE POURED AGAINST UNDISTURBED EARTH OR STRUCTURAL BACKFILL.

UNLESS OTHERWISE NOTED.

1. ALL MECHANICAL FITTINGS SHALL BE PROVIDED WITH THRUST BLOCKS AT ALL DIRECTION CHANGES

4. KEEP CONCRETE CLEAR OF JOINT, BOLTS, NUTS, CLAMPS, AND OTHER ACCESSORIES.

6. A BOND BREAKER SHALL BE PLACED BETWEEN THE PIPE AND THRUST BLOCK.

5. THRUST BLOCKS SHALL NOT BE LOCATED OR SIZED TO ENCASE ADJACENT PIPES OR FITTINGS.

2/

O .D

PI

PE

BEARING

SURFACE

BREAKER

BOND

45° (TYP)

GENERAL:

10 8.8 12.5

THE ENGINEER SHALL BE NOTIFIED.

h

H

50.9 35.3

72.0 50.0

17.3 22.6 28.6

12.7 24.5 32.0 40.5

18.0

FITTING

SIZE

(IN)

3.2 5.7

1.4

(SF)

4.5 8.0

2.0

(SF)

PLUG OR

TEE, WYE

CAP

A1

BEND

O

VERTICAL DOWNWARD BEND

IN CONCRETE (SEE TABLE

WYE

A1

1/4" PLYWOOD OVER

PLUG OR CAP

TEE

A1

FACE OF BOLTS

V1

USED FOR 11 1/4 BENDS.

A1

2 FOR SIZES)

FITTING AND EMBEDDED

COATED RODS OVER

VALVE

FITTING AND EMBEDDED

COATED RODS OVER

IN CONCRETE

(SEE NOTE 3)

1. VERTICAL BENDS THAT REQUIRE A THRUST BLOCK VOLUME EXCEEDING 5 CUBIC YARDS REQUIRE

4050 LBS/CUBIC YARD, AND A SAFETY FACTOR OF 1.5. TO COMPUTE VOLUMES FOR DIFFERENT

THRUSTS ARE BASED ON TEST PRESSURE OF 150 PSI, THE WEIGHT OF CONCRETE =

SPECIAL BLOCKING DETAILS. SEE DRAWINGS FOR VOLUMES SHOWN TO LEFT OF HEAVY, BOLD

2. THRUST BLOCK VOLUMES (TABLE 2) FOR VERTICAL DOWNWARD BENDS HAVING UPWARD RESULTANT

3. VOLUME OF THRUST BLOCK IN CUBIC YARDS FOR VALVES SHALL BE THE SAME VOLUME

(VERTICAL DOWNWARD BENDS)

TABLE 2 - VOLUME OF THRUST BLOCK IN CUBIC YARDS

VERTICAL DOWNWARD BENDS:

TEST PRESSURES AND CONCRETE WEIGHTS, USE THE FOLLOWING EQUATION:

1.73.46.8

39.0 27.1

19.9 13.8

13.3 17.3 21.9

9.7 6.8 8.8

11.2

5.0

10.0 6.9

3.4 4.4 5.6

2.5

LINE IN TABLE 2.

17.8 12.3

7.9 10.0

4.4 6.1

O

2.4 4.3

1.1

(SF)

1.2 2.2

1.0

(SF)

BEND

O

BEND

22 1/2

A2

1.0 1.1

(SF)

1.0

BEND

11 1/4 O

(CY)(IN)

3.1 2.0

0.5 1.1

SIZE

FITTING

BEND

45O

#6

9.6 6.7

4.9 3.4

5.4 4.3 3.3 2.4

2.8 2.2 1.7 1.2

#8 #8

3.0 3.0

#8 #8

#6 #8

3.0 3.0 3.0 2.5

(CY) (CY)

1.7 1.1

0.3 0.6

0.9 0.5

0.1 0.3

22 1/2

BEND

O V1

11 1/4

BEND

O

(FT)

#6 #6

#6

2.5 2.5

2.5 2.5

EMBEDMENT

SIZE

ROD

2. UNLESS OTHERWISE NOTED ON THE GENERAL DRAWINGS IN THE GENERAL NOTES OR SPECIFICATIONS, USE SOIL BEARING PRESSURE = 2000 psf FOR THIS PROJECT.

GALVANIZED OR EPOXY GALVANIZED OR EPOXY

VOLUME = (TEST PRESSURE / 150) x (4,050 / CONCRETE WEIGHT) x (TABLE 2 VALUE)

ALL PIPE JOINTS SHALL BE MECHANICALLY RESTRAINED FOR A MINIMUM OF 40 FEET IN ALL DIRECTIONS

2. FUSED HDPE PIPE & FITTINGS DO NOT REQUIRE THRUST RESTRAINTS.

FROM MECHANICAL FITTINGS.

WATER

VALVE BOX PAD

VALVE BOX COVER

ETCH FLOW DIRECTIONAL

ARROWS, PIPE DIAMETER AND

PIPE MATERIAL INTO

CONCRETE PRIOR TO CURING

AS DIRECTED BY THE

CONTRACTING OFFICER.

2'-0" SQ.x6" THICK CAST

IN PLACE CONC. PAD W/

#4 BARS E.W., SET

FLUSH IN PAVED AREAS

A

1/4"

1/4"

SECTION A

VALVE BOX PAD

VALVE BOX

VALVE BOX TOP

SECTION W/ COVER

CENTER SECTION

(LENGTH AS REQ'D)

GATE VALVE

CONCRETE

VALVE SUPPORT

ADJUSTABLE

VALVE BOX

FINISH GRADE

SET 3" ABOVE GRADE IN YARD

AREAS

VALVE BOX PAD

12" MAX

PROVIDE VALVE STEM EXTENSION

(SEE DETAIL BELOW)

VALVE BOX WITH

WIDE OVAL BASE

GATE VALVE

INSTALLATION

CONC VALVE SUPPORT,

SEE

1/8" FLAT PL CENTERING

GUIDE (SEE SECTION A)

3/4" (TYP)

NOTE:

1. PROVIDE PROTECTIVE COATING TO

EXTERIOR SURFACES OF VALVE BODY

VALVE BOX, EXTENSION STEM AN

APPURTENANCES.

ADAPTER TO FIT AWWA

SQUARE NUT

1/8"

1-1/4" DIA STEEL

EXTENSION MACHINE TO

MATCH NUT

2" AWWA SQUARE OPERATING

NUT

BUTTERFLY VALVE OR PLUG

VALVE FOR DIRECT BURIAL

REDWOOD BLOCKS 2-2"x2"x12"

LONG

CRUSHED ROCK

ADJUSTABLE VALVE BOX

FINISH GRADE

SLOPE CONC 2" AND PROVIDE

3/4" CHAMFER ALL AROUND. 2'-0"

SQ.x6" THICK CONC. PAD W/ #4

BARS E.W.

A

NOTE:

CONCRETE PAD SHALL BE

INSTALLED IN UNPAVED

AREAS. PAVED AREAS DO NOT

REQUIRE A CONCRETE PAD.

THRUST RESTRAINTS

GATE VALVE

NTSC-005

C-005 NTS

C-005

VA

R

IE

S

W

AT

ER

S

YS

TE

M D

ET

AI

LS

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-006

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

6" MIN.

TRACER WIRE

5' MAX 5' MAX

2 TRACE WIRE BOX

5' MAX

PIPE

1 TIE IN AT FITTING

TW

2TW

TRACER WIRES SHALL HAVE

A MINIMUM 24" OF SLACK

LOOSELY COILED IN THE

BOX

TEST BOX

VALVE BOX PAD, SEE DET.

2/C11

CONCRETE

ENCASEMENT (TYP)

VALVE BOX TOP

2" DUCT TAPE @ 6' MAX.

MINIMUM 3 PER LENGTH OF

PIPE

TRACER WIRE 14 GAGE SOLID

COPPER WIRE

OUT OF ASPHALT

BACKFILL

COMPACTED

MIN. WIDTH

W -3

6" M

IN

TRENCH STABILIZATION

WHERE REQD.

UNDISTURBED

EARTH (TYP)

NOTE:

8" TO 10" DEEP

DETECTABLE UTILITY

MARKING TAPE

VA

R

IE

S

BEDDING MATERIAL

1'-0"

6" MIN.

DIA.

EXISTING ASPHALT

WITH TACK COAT

UNIFORM SAW CUT LINE

EXISTING AGGREGATE BASE

NEW AGGREGATE BASE

IN ASPHALT

1'-0"

MIN.

SURFACE

1'-0"+PIPE O.D.

1. TRENCH SHALL CONFORM TO OSHA STANDARDS.

TRACER WIRE

4" ASPHALT PAVEMENT

6" AGGREGATE BASE COURSE

6" COMPACTED SUBGRADE

GRAVEL SURFACE

6" COMPACTED AGGREGATE

BASE COURSE

6" COMPACTED SUBGRADE

ASPHALT PAVING (SEE NOTE 2)

REMOVE PAVING AND

REPLACE SURFACE

COURSE (NOTE 3)

2. TRACER WIRE DETAIL 3

C-006

S-

" M

IN

COLOR PER APWA

COLOR & LABEL PER

PER APWA

5'-0"

TYP

CROSSED

UTILITY

VERTICAL THRUST

BLOCKS,

SEE DETAIL (TYP)

2 - 45° MJ BENDS

W/ RESTRAINED

JOINT GLANDS

SUITABLE FOR

PVC PIPE (TYP

BOTH SIDES)

THRUST BLOCK SEE

HORIZONTAL THRUST

BLOCK DETAIL (TYP)

WATER LINE

C-005

M

IN

6"

6"

NOTE 3

NOTE 2

TRACER WIRE

UTILITY CROSSING

TYPICAL PIPE TRENCH

PAVEMENT & GRAVEL SURFACING

NTSC-006

NTSC-006

NTSC-006

NTSC-006

D

ET

AI

LS

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-007

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

BI

D

O

PT

IO

N

2525 0 50

HORIZ.

CONSTRUCT NEW 4" HDPE WATER

MAIN

CONNECT TO EXISTING 6" FIRE

SERVICE LATERAL. USE 4" TEE

AND 4"X6" INCREASER

CONNECT TO BUILDING

SEE SHEET C-009

NEW 4" TEE AND GATE VALE

AT SUPPLY SIDE OF TEE

NOTES

1. WATER MAIN CONSTRUCTED UNDER THE BID OPTION MAY BE CONSTRUCTED USING A

VARIETY OF TECHNIQUES, INCLUDING TRENCHED AND TRENCHLESS.

2. TRENCHLESS TECHNIQUES MAY INCLUDE HDD, OR PIPE BURSTING.

3. IT MAY BE FEASIBLE TO UTILIZE THE EXISTING 6" WATER MAIN BY SLIP LINING WITH 4"

HDPE PIPE. SLIGHT ADJUSTMENTS TO THE PLAN WILL BE REQUIRED FROM WHAT IS

SHOWN.

NEW 4"X6" INCREASER

CONNECT (E) 6" SUPPLY TO

(N) 4" HDPE WATER MAIN AT TEE

(E) SERVICE TO REMAIN AS-IS

NOT IN PROJECT SCOPE

TRENCH & EXCAVATION EXCESS SPOILS

CAN BE PILED IN DESIGNATED SPACE

FINAL SPACE LOCATION TO BE

COORDINATED W/ NPS

PRIOR TO CONSTRUCTION

/1

7/

A M

E N

D M

E N

+0

+1

SUBSHEET

SHEET

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-008

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

BI

D

O

PT

IO

N

2525 0 50

HORIZ.

LOCATE AND CONNECT NEW 4"

SUPPLY TO EXISTING HYDRANT

BEGIN BID OPTION AT ENDING OF BASE BID

WATER MAIN. RATHER THAN CONNECT TO EXISTING

CONSTRUCT NEW 4" HDPE WATER MAIN.

LOCATE & CONNECT TO EXISTING

LOCATE & CONNECT TO EXISTINGEXISTING SERVICES

TO BE ABANDONED IN PLACE

LOCATE AND

CONNECT NEW 4"

SUPPLY TO

EXISTING HYDRANT

/1

7/

A M

E N

D M

E N

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-009

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

TREATMENT PLAN PLAN

NTS

F&I 6" TEE

F&I HYDRANT ASSEMBLY

(PAINT PURPLE)

DISCONNECT OUTLET AND

CAP TEE END

F&I 4" TEE

F&I STATE APPROVED (HIGH HAZARD FIRE CONNECTION)

REDUCED PRESSURE BACKFLOW

ASSEMBLY. BASIS OF DESIGN AMES LMF500 (MAXIUM 500)

REMOVE 2" PIPE AND ACCESSORIES BETWEEN

GATE VALVES AND RECONNECT WITH 4" LINE.

PATCH HOLE IN BUILDINGREMOVE GATE VALVE AFTER TEST

NOTES

1. WORK TO THE PLANT WILL ONLY BE ALLOWED AFTER THE WATER MAIN CONSTRUCTION.

2. PRIOR TO WORKING ON THE PLANT, THE CONTRACTOR SHALL VERIFY STATIC

PRESSURE , AND CONDUCT A FLOW TEST. THE PURPOSE OF THE FLOW TEST WILL BE

TO VERIFY THAT THE MODIFIED WATER MAIN CAN DELIVER THE AMOUNT OF FLOW

REQUIRED BASED ON A 4-INCH LINE SIZE. THE FLOW TEST WILL CONFIRM THAT THERE

ARE NO OTHER RESTRICTIONS ALONG THE LINE THAT THE NPS IS NOT AWARE OF.

3. IF THE FLOW TEST FAILS, NOTIFY THE NPS IMMEDIATELY.

4. THERE IS AN EXISTING HYDRANT ASSEMBLY NEAR THE TREATMENT BUILDING THAT

WAS DAMAGED AND IS BADLY CORRODED. REPLACE THE FULL ASSEMBLY INCLUDING

THE TEE FITTING. FULLY EXCAVATE AND REMOVE SOIL WITHIN 3' OF ALL ASSEMBLY

COMPONENTS. BACKFILL WITH COMPACTED APPROVED SOIL BROUGHT IN FROM

OUTSIDE SOURCE. THE SOIL THAT WAS USED TO BACKFILL THE EXISTING ASSEMBLY

WAS FOUND TO BE BEACH SAND WHICH LED TO THE FAILURE OF THE FITTINGS DUE TO

CORROSION. IF BID OPTION 1 IS EXECUTED, THE FIRE ASSEMBLY WILL CONNECT

DIRECTLY TO THE NEW 4" MAIN.

CONDUCT FLOW TEST BY DISSEMBLING

PIPE DOWNSTREAM OF 4" GATE VALVE.

REMOVE GATE VALVE AFTER TEST

BI

D

O

PT

IO

N

REPLACE HYDRANT ASSEMBLY.

SEE NOTE 4

F&I 4" GATE VALVE

DRAWN BY:

PMIS NO.

D

ES

C R

IP

TI

O N

D

AT

E N

O

R

EV

IS

IO

N S

309710

NWA

C-010

D

EL

N O

R

TE

C O

U N

TY

C

AL

IF

O R

N

IA

W O

LF

C

R

EE

K W

AT

ER

S

YS

TE

M

R

EH

AB

IL

IT

AT

IO

N

TIC NO.

167-192197

BI

D

O

PT

IO

N

REDW 309710 DESIGN_BID OPTION-G-001
Sheets and Views
REDW 309710 DESIGN_BID OPTION-G-001
REDW 309710 DESIGN_BID OPTION-G-002
Sheets and Views
REDW 309710 DESIGN_BID OPTION-G-002
REDW 309710 DESIGN_BID OPTION-C-001
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-001
REDW 309710 DESIGN_BID OPTION-C-002
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-002
REDW 309710 DESIGN_BID OPTION-C-003
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-003
REDW 309710 DESIGN_BID OPTION-C-004
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-004
REDW 309710 DESIGN_BID OPTION-C-005
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-005
REDW 309710 DESIGN_BID OPTION-C-006
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-006
REDW 309710 DESIGN_BID OPTION-C-007
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-007
REDW 309710 DESIGN_BID OPTION-C-008
Sheets and Views
C-008
REDW 309710 DESIGN_BID OPTION-C-009
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-009
REDW 309710 DESIGN_BID OPTION-C-010
Sheets and Views
REDW 309710 DESIGN_BID OPTION-C-010

File details come from the government source that posted it. Updated .