This document appears to be an Attachment to a Request for Quotation (RFQ) for the replacement of the exterior rooftop sprinkler system at the Oregon Caves National Monument and Preserve in Oregon. The project is estimated to cost between $100,000 and $250,000 and is set aside for small businesses under NAICS code 238220. The government anticipates awarding a firm-fixed-price purchase order to the responsible quoter whose quotation is most advantageous, price and other factors considered. Key details include a required site visit on September 6, 2024, and the submission of quotations via email by the date and time specified in the RFQ. The solicitation provides detailed specifications, drawings, and other attachments to describe the requirements. Prospective vendors are instructed to submit questions via email as directed in the RFQ.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P8424Q0117_Amd_0001.pdf | ||
| B11_Site_Visit_Sign_In_Sheet_ORCA_Replace_Roof_Fire_Suppression_0001.pdf | ||
| B12_Miscellanious_Correspondence_Questions_and_Answers_ORCA_Roof_Fire_System_0001.pdf | ||
| A06_Specifications_ORCA_Roof_Fire_System.pdf | ||
| B08_Attachment_5_140P8424Q0117_SF24.pdf | ||
| Sol_140P8424Q0117.pdf | ||
| B08_Solicitation_ATT_4_Tech_Info_Form_140P8424Q0117.pdf | ||
| A06_Drawings_ORCA_Roof_Fire_System.pdf | ||
| B03_Wage_Determination_ORCA_Roof_Fire_System.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS-CONTAINING MATERIALS
SURVEY REPORT
FOR
NATIONAL PARK SERVICE
UNITED STATES DEPARTMENT OF THE INTERIOR
OREGON CAVES NATIONAL MONUMENT
CAVE JUNCTION, OREGON
Prepared For:
NATIONAL PARK SERVICE
1201 Eye Street NW, 10th Floor
Washington, DC 20006
Prepared By:
MACTEC ENGINEERING AND CONSULTING, INC.
396 Plasters Avenue, Atlanta, Georgia 30324
November 17, 2011
MACTEC Project Number 6141-10-0016
National Park Service; ORCA, Cave Junction, Oregon Asbestos-Containing Materials Survey Report MACTEC Project 6141-10-0016 November17, 2011
Page i
TTAABBLLEE OOFF CCOONNTTEENNTTSS
Table of Contents ............................................................................................................................................... i
1.0 Executive Summary
2.0 Background Information
2.1 Facility Description
3.0 Summary of Review of Existing Data and Interview of On-Site Personnel
3.1 Interview of Onsite Personnel
3.2 Review of Previous Asbestos-Related Information
4.0 Survey of Suspect Asbestos-Containing Materials Scope
4.1 Visual Survey
4.2 Methodology
4.3 Existing Data
4.4 Supplemental Sample Collection and Analysis
5.0 Findings
5.1 Located ACM
6.0 Opinion of Abatement Costs of Located ACM
6.1 Previous Asbestos-Related Costs
6.2 Current Asbestos-Containing Material Cleanup and Management
6.3 Future Asbestos-Containing Material Cleanup Costs
7.0 Conclusions and Recommendations
Attachments:
Tables: 1. Summary of Suspect ACM Observed
2. Summary of ACM Located
Appendices: A. Photographs of Buildings included in this Survey B. Photographs and Supplemental Information for Non-ACM C. Photographs and Supplemental Information for Located ACM D. Laboratory Results of Bulk Samples E. Inspector and Laboratory Accreditations
11..00 EEXXEECCUUTTIIVVEE SSUUMMMMAARRYY
The National Park Service (NPS) contracted MACTEC Engineering and Consulting, Inc. (MACTEC) to provide asbestos assessment services at select Parks to assist NPS with establishing an Asbestos Assessment Program (AAP). The intent of the AAP is to evaluate and supplement existing asbestos related data to assist NPS with complying with existing applicable Federal, State and local regulations related to asbestos. The AAP will provide objective data related to the impact of asbestos-containing materials (ACM) for the planning and execution of future maintenance, renovation, construction, and demolition efforts related to Park facilities. Additionally, information obtained through the asbestos assessment and survey effort will be used by the NPS Washington Support Office to compile the necessary data to respond to the Federal Accounting Standards Advisory Board Technical Bulletin 2006-1, Recognition and Measurement of Asbestos-Related Cleanup Costs.
The site specific asbestos survey assessment of Oregon Caves National Monument, in Cave Junction, Oregon was performed between April 18 and August 31, 2011. The asbestos survey and sampling was performed by accredited asbestos inspectors from MACTEC. Asbestos surveys were performed on 17 buildings/structures at the Park.
During the interview with the NPS representative, it was learned that the building list provided to MACTEC by NPS excluded three buildings that were at the site. These three buildings were included in the survey.
Additionally, it was learned that no previous asbestos related information was available for the Park.
During the survey efforts, 224 bulk samples were collected of suspect asbestos-containing materials. These samples were analyzed by a laboratory accredited by the National Voluntary Laboratory Accreditation Program. The samples were analyzed by polarized light microscopy and reported as percent asbestos in each sample.
The survey located asbestos-containing materials in six buildings. The asbestos-containing materials were assessed as being undamaged at the time of the survey.
Due to the lack of existing data/information, no previous asbestos related expenses were identified. The current asbestos related expenses are $20,341. The opinion of cost for asbestos cleanup is estimated to be $102,700.
22..00 BBAACCKKGGRROOUUNNDD IINNFFOORRMMAATTIIOONN
The National Park Service (NPS) contracted MACTEC Engineering and Consulting, Inc. (MACTEC) to provide asbestos assessment services at select Parks to assist NPS with establishing an Asbestos Assessment Program (AAP). The intent of the AAP is to evaluate and supplement existing asbestos related data to assist NPS with complying with existing applicable Federal, State, and local regulations related to asbestos. The AAP will provide objective data related to the impact of asbestos-containing materials (ACM) for the planning and execution of future maintenance, renovation, construction, and demolition efforts related to Park facilities. Additionally, information obtained through the asbestos assessment and survey effort will be used by the NPS Washington Support Office to compile the necessary data to respond to the Federal Accounting Standards Advisory Board Technical Bulletin 2006-1, Recognition and Measurement of Asbestos-Related Cleanup Costs.
The scope of work for this project included asbestos related survey and assessment efforts to evaluate existing survey information and perform supplemental sampling as necessary to comply with established sampling guidance and protocols. The asbestos survey process included a review of existing asbestos survey information (if provided), an interview of appropriate Park site personnel, visual surveys of readily accessible interior and exterior areas of the various structures to locate suspect ACM, and the collection and laboratory analyses of bulk samples of located suspect ACM.
Following identification, delineation, and quantification of ACM within structures at the Park, an opinion of abatement cost was prepared for each structure where ACM was located and summarized for the Park as a whole. To the extent possible, the opinion of costs included asbestos-related costs incurred by the Park to date when documentation of the expenditure of funds was provided for review. However, when documentation of actual costs was not provided, these expenditures were not reported.
2.1 FACILITY DESCRIPTION
The Oregon Caves National Monument (ORCA) is located in Cave Junction, Oregon. NPS initially reported to MACTEC that 14 structures were present at the Park. During the interview with John Cavin, it was learned that three additional structures were located at the site. These three buildings not on the building list provided to MACTEC by NPS were also included in the survey. Therefore, 17 structures were surveyed for ACM. Appendix A provides a summary of the buildings included in the survey.
33..00 SSUUMMMMAARRYY OOFF RREEVVIIEEWW OOFF EEXXIISSTTIINNGG DDAATTAA AANNDD IINNTTEERRVVIIEEWW OOFF
OONN--SSIITTEE PPEERRSSOONNNNEELL
MACTEC requested and, when provided by NPS, reviewed general types of asbestos information as follows:
1. Information related to the construction of facilities and structures at the site. The intent of this review was to gain an understanding if asbestos was specified and/or installed during construction.
2. Existing asbestos survey data, asbestos Operations and Maintenance Programs, and other asbestos related information. The intent of the review was to gain an understanding of the scope and extent of previous survey efforts including locations, quantities and condition of previously located ACM and non-ACM. The purpose of reviewing this information would be to assess the need for supplemental sampling and analyses.
3. Previous asbestos abatement actions or monitoring. The purpose of reviewing previous asbestos abatement efforts and evaluation of replacement materials was to assess the need for supplemental sampling and analyses.
4. Information related to any previous expenditure of funds related to asbestos for the above referenced information. The purpose of reviewing this information was to provide NPS with a summary of past asbestos-related costs.
5. Information obtained from interviews of onsite personnel familiar with the history of the Park’s construction and operation. The purpose of the interviews was to obtain pertinent information related to building construction/materials, previous and current uses, and previous or planned renovations/modifications to the facilities.
3.1 INTERVIEW OF ONSITE PERSONNEL
MACTEC interviewed John Cavin, while onsite. During the interview, Mr. Cavin stated that there were no immediate plans for renovation or demolition at the ORCA Park.
3.2 REVIEW OF PREVIOUS ASBESTOS-RELATED INFORMATION
No asbestos related documents were provided. MACTEC was informed by NPS personnel that no previous asbestos related data or information for the Park exists.
44..00 SSUURRVVEEYY OOFF SSUUSSPPEECCTT AASSBBEESSTTOOSS--CCOONNTTAAIINNIINNGG MMAATTEERRIIAALLSS
SSCCOOPPEE
The United States Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA) have published regulations, guidelines, and recommendations regarding inspection and sampling for installed ACM. These regulations, guidelines, and recommendations were adhered to as appropriate within the scope of this survey. The State of Oregon does not have any specific Asbestos inspector licensing or survey requirements beyond those of the Federal Government.
Current EPA and OSHA guidelines allow accredited asbestos Inspectors to categorize certain materials as non-suspect asbestos-containing materials based on visual evaluation. Examples of these non-suspect ACM include fiberglass, rubber, Styrofoam©, cork, foam glass, wood, concrete, glass, and metal. MACTEC did not inventory, sample, or otherwise assess these non-suspect materials when encountered.
Current EPA and OSHA guidelines allow accredited asbestos Inspectors to assume suspect materials contain asbestos. MACTEC’s survey protocol relative to NPS facilities included sampling and analyses of composite shingled roof materials, where safe access could be obtained. However, in order to preserve the integrity of roofing systems, when roofing materials other than composite shingled materials were observed, these suspect materials were assumed to be ACM.
4.1 Visual Survey
The visual survey consisted of a walk-through of each structure included to be surveyed at the Park to locate, inventory, quantify and document the condition of suspect ACM. The survey efforts included reasonably accessible interior and exterior areas of each structure at the Park. Destructive evaluation was not performed to evaluate for concealed suspect ACM located beneath multiple layers of flooring, within wall/ceiling cavities and/or chases, or other locations that were not readily accessible. Suspect materials observed during the survey were grouped into “homogeneous materials”. A homogeneous material is one that appears to be uniform in color and texture and appears to have been applied or installed during the same general time period. Homogeneous materials can be friable or nonfriable. Friable materials are those that when dry can be crumbled, pulverized or reduced to powder by hand pressure. Nonfriable materials are those which when dry cannot be crumbled, pulverized or reduced to powder by hand pressure. Nonfriable materials can become friable when they are disturbed, become deteriorated, or are aggressively contacted.
For reference, MACTEC developed room designations during our visual survey. Each room, area, or groups of rooms were assigned a unique (arbitrary) number. For the purposes of this survey effort, a room is a discrete area within the surveyed structure that may correspond to physical rooms (e.g., doors and walls), a discrete space (e.g., mezzanine or roof), or other identifiable space such as a department, suite, or group of rooms. When drawings for a building/structure were not provided by NPS, MACTEC may have designated an entire building as a single room and referenced areas/rooms within that building/structure based on the physical lay-out of the structure (i.e., northwest office, entrance, storage, kitchen, restroom, etc.).
4.2 Methodology
When supplemental sampling and analyses were performed, representative bulk samples (some with multiple layers) were collected of homogeneous suspect asbestos-containing materials located during the visual survey. The sampling was performed in general accordance with the sampling requirements of the Asbestos Hazard Emergency Response Act (AHERA) regulation [40 CFR 763.86] for each homogeneous material. The bulk samples were sealed in airtight containers, labeled, and delivered to MACTEC’s National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory in Atlanta, Georgia.
Samples were analyzed for asbestos content by Polarized Light Microscopy (PLM) in general accordance with EPA method 600/R-93/116.
4.3 Existing Data
There was no existing data or information related to asbestos provided to MACTEC for this Park.
4.4 Supplemental Sample Collection and Analysis
Sampling and analyses of suspect asbestos-containing materials were performed. The asbestos survey and sample collection were performed by Matt Walraven and Josh Januzelli of MACTEC. Mr. Walraven and Mr. Januzelli are accredited asbestos Inspectors; evidence of accreditation is provided in Appendix E. The site evaluation services were performed between April 19 and August 31, 2011.
A total of 224 samples were collected from structures at the Park. All samples were analyzed by PLM with no additional analytical evaluation.
55..00 FFIINNDDIINNGGSS
The detailed findings of the survey are provided in the tables, appendices, and attachments following the body of this report. Each of these sections is presented by building name and NPS building identification number and is described below. Refer to these sections for detailed information associated with the materials located during the survey efforts.
Table 1.0 - Summary of Suspect ACM Observed includes the following for each material observed during our survey:
• Homogeneous material identification number;
• A physical description of each suspect ACM observed;
• The associated substrate or component and associated building system;
• The AHERA category (material type), and;
• Suspect Material Classification (previously sampled, sampled, assumed).
Table 2.0 - Summary of Identified ACM includes the following for each ACM material:
• Homogeneous material identification number;
• A physical description of the ACM located;
• The associated substrate or component and associated building system;
• The AHERA category (material type);
• Documentation of friability, and;
• Material classification.
Appendix A – Building Summary:
• Presents a picture of the building/structure (if available);
• Building number and name (as defined by NPS);
• Building use;
• Building size;
• Construction date;
• Reference to ACM;
• Asbestos related costs.
Appendix B – Non-ACM Detail and Photographs:
• Building/structure identification number;
• A representative photograph of the non-ACM homogeneous material;
• The information summarized in Table 1, and;
• Bulk sample information including sample location and sample results.
Appendix C - ACM Detail and Photographs:
• Building/structure identification number;
• A representative photograph of the ACM homogeneous material;
• The information summarized in Table 2, and;
• Bulk sample information including sample location, sample results, homogeneous material locations, quantity and condition.
Laboratory results of bulk samples are included in Appendix D. Inspector and Laboratory Accreditations and Certifications are included in Appendix E.
5.1 LOCATED ACM
Asbestos-containing materials were located in the following buildings: Chalet (43034), Chateau (43045), Guide Shack (43048), Maintenance Shop (43054), Residence #5 (43055), H20 Maintenance Shop Area
(43058). Please see Appendix C for the assessments of the asbestos-containing materials that were evaluated at the time of the survey.
66..00 OOPPIINNIIOONN OOFF AABBAATTEEMMEENNTT CCOOSSTTSS OOFF LLOOCCAATTEEDD AACCMM
6.1 PREVIOUS ASBESTOS-RELATED COSTS
Previous asbestos related data was not located or provided for the Park.
6.2 CURRENT ASBESTOS-CONTAINING MATERIAL CLEANUP AND MANAGEMENT
The cost to perform this survey at this Park, including analytical efforts, reporting, expenses, and management, is $20,341. This expense is provided in Appendix A and has been allocated proportionally by square feet per building/structure area.
6.3 FUTURE ASBESTOS-CONTAINING MATERIAL CLEANUP COSTS
The total estimated cost for the removal of ACM identified at this Park is $102,700. These expenses are provided by building in Appendix A. This total cleanup cost includes asbestos removal and disposal. The cost does not include management of the ACM prior to removal.
77..00 CCOONNCCLLUUSSIIOONNSS AANNDD RREECCOOMMMMEENNDDAATTIIOONNSS
Based on findings presented in this report, MACTEC offers the following conclusions and recommendations:
1. Avoid disturbance of ACM presented in this report. Inadvertent or improper disturbance of ACM can create exposures to asbestos at or above the permissible exposure limits established by OSHA.
MACTEC has recommended that the ACM at the site be managed in place. They should be included in an Asbestos Operations and Maintenance Program (O&M), which provides policies and work practices for the performance of work on or around asbestos-containing materials presented in Table 2. The O&M Program should contain the necessary elements to comply with and document compliance with the OSHA Asbestos General Industry Standard [29 CFR 1910.1001] and the OSHA Construction Asbestos Standard [29 CFR 1926.1101].
2. Prior to disturbing concrete masonry unit wall sections, MACTEC recommends that an accredited asbestos Inspector evaluate the wall system for the presence of vermiculite within the section of the wall to be disturbed. If vermiculite is located, representative bulk samples should be collected and appropriately analyzed to evaluate for asbestos in the vermiculite.
3. Prior to disturbing materials assumed to be ACM, MACTEC recommends that an accredited asbestos Inspector evaluate the materials and collect representative bulk samples if applicable to be appropriately analyzed to evaluate for asbestos content.
4. If any suspect materials are discovered that have not been addressed in this report, MACTEC recommends that work activities that may disturb the materials be halted and the materials be assumed to be asbestos-containing until an appropriate evaluation (which may include sampling and analysis) of the materials is performed by an accredited asbestos Inspector to confirm or rebut the presence of asbestos.
5. Due to the non-destructive nature of the survey performed by MACTEC, it may be necessary to perform additional destructive evaluations of areas of the facility prior to renovation and/or demolition activities. The additional evaluations should focus on locating materials that were concealed and not accessible during these survey activities.
6. Current Regulations require that ACM be removed and properly disposed of prior to demolition or renovation activities that disturb RACM. NESHAP Regulations also require a notification to be submitted 10 working days prior to any demolition project, regardless of the presence or absence of ACM. The OSHA Construction Standard and the EPA-NESHAP require that contractors have a “competent person” on site to identify and properly address unreported suspect asbestos that is discovered during renovation or demolition.
7. We recommend that the asbestos-containing materials be removed and disposed of prior to disturbance during the demolition/renovation efforts. The ACM removal should be performed by a qualified and licensed asbestos abatement contractor under controlled conditions. We recommend that the abatement be designed and monitored by a qualified asbestos consulting firm, not retained by the abatement contractor, to represent the builder’s interest.
TTAABBLLEESS
TABLE 1.0 - SUMMARY OF SUSPECT ACM
Oregon Caves National Monument Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 1 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43034 - BLDG Chalet (hs) QMIS- 00000001
Resilient Sheet Flooring, Off White, Small Pattern Misc.Floor TileORCA.43034.001a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.Floor TileORCA.43034.001b Floor Sampled
12" x 12" Floor Tile, Off White, Gray Streaks Misc.ConcreteORCA.43034.001c Floor Sampled
Floor Tile Mastic, Rust, Smooth Misc.ConcreteORCA.43034.001d Floor Sampled
2' x 4' Ceiling Tile (Lay-in), White, Pindot Misc.Metal GridORCA.43034.002a Ceiling Sampled
2' x 4' Ceiling Tile (Lay-in), White, Pindot/Small Fissure Misc.Metal GridORCA.43034.003a Ceiling Sampled
Resilient Sheet Flooring, Light Gray, Brick Pattern Misc.ConcreteORCA.43034.004a Floor Sampled
Sheet Flooring Adhesive, Clear, Smooth Misc.ConcreteORCA.43034.004b Floor Sampled
Covebase, Brown, Smooth Misc.WallORCA.43034.005a Wall Sampled
Covebase Mastic, Brown, Stippled Misc.WallORCA.43034.005b Wall Sampled
Plaster, White, Smooth SurfacingWallboardORCA.43034.006a Wall Sampled
Plasterboard, Gray, Drilled Holes Misc.Wall StudsORCA.43034.006b Wall Sampled
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43034.007a Roof Sampled
Carpet Mastic, Yellow, Under Existing Finishes Misc.ConcreteORCA.43034.009a Floor Sampled
Resilient Sheet Flooring, Brown/Gray, Stone Pattern Misc.WoodORCA.43034.010a Floor Sampled
Sheet Flooring Adhesive, Under Existing Finishes Misc.WoodORCA.43034.010b Floor Sampled
Covebase, Black Misc.WallboardORCA.43034.011a Wall Sampled
Covebase Mastic, Under Existing Finishes Misc.WallboardORCA.43034.011b Wall Sampled
Resilient Sheet Flooring, Brown, Stone Pattern Misc.WoodORCA.43034.012a Floor Sampled
Sheet Flooring Adhesive, Under Existing Finishes Misc.WoodORCA.43034.012b Floor Sampled
12" x 12" Floor Tile, Beige, Floral Pattern Misc.WoodORCA.43034.013a Floor Sampled
Floor Tile Mastic, Under Existing Finishes Misc.WoodORCA.43034.013b Floor Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 2 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43034 - BLDG Chalet (hs) QMIS- 00000001
Resilient Sheet Flooring, Rust, Stone Pattern Misc.WoodORCA.43034.014a Floor Sampled
Sheet Flooring Adhesive, Under Existing Finishes Misc.WoodORCA.43034.014b Floor Sampled
9" x 9" Floor Tile, Gray, Blue Streaks Misc.ConcreteORCA.43034.015a Floor Sampled
Floor Tile Mastic, Under Existing Finishes Misc.ConcreteORCA.43034.015b Floor Sampled
Resilient Sheet Flooring, Brown, Stone Chip Pattern Misc.ConcreteORCA.43034.016a Floor Sampled
Sheet Flooring Adhesive, Under Existing Finishes Misc.ConcreteORCA.43034.016b Floor Sampled
Floor Tile Mastic, Black, Residual Misc.ConcreteORCA.43034.017a Floor Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43037 - BLDG Ranger Cabin (hs)
Wallboard, White, Light Texture Misc.Wall StudsORCA.43037.001a Wall/Ceiling Sampled
Wallboard Joint Compound, White, Light Texture Misc.WallboardORCA.43037.002a Wall/Ceiling Sampled
Resilient Sheet Flooring, Light Blue, Square Pattern Misc.WoodORCA.43037.003a Floor Sampled
Sheet Flooring Adhesive, Yellow Misc.WoodORCA.43037.003b Floor Sampled
Resilient Floor Covering/Tread, Light Brown, Asphaltic Misc.WoodORCA.43037.004a Floor Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43041 - BLDG Admin Hq Building
Wallboard, Off White, Light Texture Misc.Walls/CeilingsORCA.43041.001a Wall/Ceiling Sampled
Wallboard Joint Compound, White, Light Texture Misc.Walls/CeilingsORCA.43041.001b Wall/Ceiling Sampled
Covebase, Dark Brown, Smooth Misc.WallboardORCA.43041.002a Wall Sampled
Covebase Mastic, White, Light Texture Misc.WallboardORCA.43041.002b Wall Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 3 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43041 - BLDG Admin Hq Building
Resilient Sheet Flooring, Orange, Multi-Colored Misc.Various SurfacesORCA.43041.003a Floor/Wall Sampled
Mastic/Adhesive, Yellow, Smooth Misc.Various SurfacesORCA.43041.003b Floor/Wall Sampled
2' x 2' Ceiling Tile (Lay-in), White, Light Texture Misc.Metal GridORCA.43041.004a Ceiling Sampled
12" x 12" Floor Tile, White, Black Streaks Misc.FloorORCA.43041.005a Floor Sampled
Floor Tile Mastic, Yellow, Light Texture Misc.FloorORCA.43041.005b Floor Sampled
Sink Undercoating, White, Stippled Misc.SinkORCA.43041.006a Plumbing Fixtures Sampled
Roof Shingles, Gray, Rough Misc.Roof DeckORCA.43041.007a Roof Sampled
Roofing Felt, Black, Fibrous Misc.Roof DeckORCA.43041.007b Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43045 - BLDG Chateau (hs)
Tank Insulation, White, Woven TSIStorage TankORCA.43045.001a Boiler Sampled
Flange Gasket, Concealed Misc.Pipe FlangesORCA.43045.002a Fire Suppression Assumed ACM
Wallboard, White Misc.Wall StudsORCA.43045.003a Wall/Ceiling Sampled
Wallboard Joint Compound, White Misc.WallboardORCA.43045.004a Wall/Ceiling Sampled
Plaster, White SurfacingLatheORCA.43045.005a Wall/Ceiling Sampled
12" x 12" Floor Tile, Light Brown, Mottled Misc.WoodORCA.43045.006a Floor Sampled
Floor Tile Mastic, Tan Misc.WoodORCA.43045.006b Floor Sampled
Fire Doors, Suspect Core Misc.Various ComponentsORCA.43045.007a Fire Suppression Assumed ACM
Fiberboard, White, Smooth Misc.Wall StudsORCA.43045.008a Ceiling Sampled
9" x 9" Floor Tile, Yellow, Red Streaks Misc.ConcreteORCA.43045.009a Floor Sampled
Floor Tile Mastic, Black Misc.ConcreteORCA.43045.009b Floor Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 4 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43045 - BLDG Chateau (hs)
9" x 9" Floor Tile, Tan, White Streaks Misc.ConcreteORCA.43045.010a Floor Sampled
Floor Tile Mastic, Black Misc.ConcreteORCA.43045.010b Floor Sampled
Resilient Sheet Flooring, Multi-Colored, Stone Chip Pattern Misc.Various SurfacesORCA.43045.011a Floor Sampled
Sheet Flooring Adhesive, Gray Misc.Various SurfacesORCA.43045.011b Floor Sampled
9" x 9" Floor Tile, Light Brown, Multi-Colored Streaks Misc.WoodORCA.43045.012a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.012b Floor Sampled
12" x 12" Floor Tile, Blue Misc.Various SurfacesORCA.43045.013a Floor Sampled
Floor Tile Mastic, Clear Misc.Various SurfacesORCA.43045.013b Floor Sampled
12" x 12" Floor Tile, Green, Multi-Colored Streaks Misc.WoodORCA.43045.014a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.014b Floor Sampled
12" x 12" Floor Tile, Beige, Multi-Colored Streaks Misc.WoodORCA.43045.015a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.015b Floor Sampled
1' x 1' Ceiling Tile (Splined), White, Drilled Holes Misc.WoodORCA.43045.016a Wall/Ceiling Sampled
Fiberboard, Brown Misc.Wall StudsORCA.43045.017a Wall/Ceiling Sampled
Resilient Sheet Flooring, Light Brown Misc.WoodORCA.43045.018a Floor Sampled
Sheet Flooring Adhesive, Gray Misc.WoodORCA.43045.018b Floor Sampled
Covebase, Black Misc.Various Wall SurfacesORCA.43045.019a Wall Sampled
Covebase Mastic, Brown Misc.Various Wall SurfacesORCA.43045.019b Wall Sampled
Resilient Sheet Flooring, White, Black Specks Misc.WoodORCA.43045.020a Floor Sampled
Sheet Flooring Adhesive, Tan Misc.WoodORCA.43045.020b Floor Sampled
1' x 1' Ceiling Tile (Splined), White, Small Pinhole Misc.WoodORCA.43045.021a Ceiling Sampled
Carpet Mastic, Yellow, Under Existing Finishes Misc.WoodORCA.43045.022a Floor Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 5 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43045 - BLDG Chateau (hs)
Stair Tread, Black Misc.StairsORCA.43045.023a Floor Sampled
Stair Tread Mastic, Clear Misc.StairsORCA.43045.023b Floor Sampled
9" x 9" Floor Tile, Green/White, Checkerboard Misc.WoodORCA.43045.024a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.024b Floor Sampled
9" x 9" Floor Tile, Green, Mottled Misc.WoodORCA.43045.025a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.025b Floor Sampled
12" x 12" Floor Tile, White, Gray Specks Misc.WoodORCA.43045.026a Floor Sampled
Floor Tile Mastic, Tan Misc.WoodORCA.43045.026b Floor Sampled
9" x 9" Floor Tile, White, Green Streaks Misc.WoodORCA.43045.027a Floor Sampled
Floor Tile Mastic, Black Misc.WoodORCA.43045.027b Floor Sampled
Resilient Sheet Flooring, Off White, Stone Chip Pattern Misc.WoodORCA.43045.028a Floor Sampled
Sheet Flooring Adhesive, Tan Misc.WoodORCA.43045.028b Floor Sampled
Roofing Felt, Black, Under Existing Finishes Misc.Roof DeckORCA.43045.029a Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43048 - BLDG Guide Shack(hs)
Wallboard, White, Light Texture Misc.Wall StudsORCA.43048.001a Wall Sampled
Wallboard Joint Compound, White, Smooth Misc.WallboardORCA.43048.001b Wall Sampled
9" x 9" Floor Tile, Light Brown, White Streaks Misc.FloorORCA.43048.002a Floor Sampled
Floor Tile Mastic, Black, Ridged Misc.FloorORCA.43048.002b Floor Sampled
Resilient Sheet Flooring, Light Gray, Square Pattern Misc.FloorORCA.43048.003a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.43048.003b Floor Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 6 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43048 - BLDG Guide Shack(hs)
Resilient Sheet Flooring, Off White, Tan Streaks Misc.FloorORCA.43048.004a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.43048.004b Floor Sampled
Resilient Sheet Flooring, Off White, White Misc.FloorORCA.43048.005a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.43048.005b Floor Sampled
Covebase, Brown, Smooth Misc.WallORCA.43048.006a Wall Sampled
Covebase Mastic, Brown, Smooth Misc.WallORCA.43048.006b Wall Sampled
Wall Panel Adhesive, Yellow, Ridged Misc.WallORCA.43048.007a Wall Sampled
Window Glazing, Off White, Light Texture Misc.Windows & DoorsORCA.43048.008a Windows Sampled
Felt Paper, Black, Paper Misc.WoodORCA.43048.009a Building Exterior Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43050 - BLDG Kiosk (hs)
Waterproofing, Black, Paper Misc.ConcreteORCA.43050.001a Floor Sampled
Waterproofing, Black, Paper Misc.ConcreteORCA.43050.002a Building Exterior Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43052 - BLDG Tractor Shed
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43052.001a Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43053 - BLDG Garage
Wallboard, White, Light Texture Misc.Walls/CeilingsORCA.43053.001a Wall/Ceiling Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 7 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43053 - BLDG Garage
Wallboard Joint Compound, White, Light Texture Misc.StudsORCA.43053.001b Wall/Ceiling Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43054 - BLDG Maint Shop
12" x 12" Floor Tile, Beige, Brown Streaks Misc.ConcreteORCA.43054.001a Floor Sampled
Mastic/Adhesive, Off White, Smooth Misc.ConcreteORCA.43054.001b Floor Sampled
Wallboard Joint Compound, White, Smooth Misc.Walls/CeilingsORCA.43054.002a Wall Sampled
Roofing Felt, Black, Fibrous Misc.Roof DeckORCA.43054.003a Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43055 - Residence # 5 Qmis # 00000005
Wallboard, White, Light Texture Misc.Walls/CeilingsORCA.43055.001a Wall/Ceiling Sampled
Wallboard Joint Compound, White, Light Texture Misc.Walls/CeilingsORCA.43055.001b Wall/Ceiling Sampled
Resilient Sheet Flooring, Tan, Square Pattern Misc.FloorORCA.43055.002a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.43055.002b Floor Sampled
Covebase, Beige, Smooth Misc.WallORCA.43055.003a Wall Sampled
Covebase Mastic, Brown, Light Texture Misc.WallORCA.43055.003b Wall Sampled
Resilient Sheet Flooring, Tan, Beige Streaks Misc.FloorORCA.43055.004a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.43055.004b Floor Sampled
Covebase, Off White, Smooth Misc.WallORCA.43055.005a Wall Sampled
Covebase Mastic, Brown, Light Texture Misc.WallORCA.43055.005b Wall Sampled
Resilient Sheet Flooring, Tan, Gray Misc.FloorORCA.43055.006a Floor Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 8 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43055 - Residence # 5 Qmis # 00000005
Sheet Flooring Adhesive, White, Smooth Misc.FloorORCA.43055.006b Floor Sampled
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43055.007a Roof Sampled
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43055.007b Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43056 - BLDG Visitor Center Cave Junction
Wallboard, White, Light Texture Misc.Wall StudsORCA.43056.001a Wall/Ceiling Sampled
Wallboard Joint Compound, White, Light Texture Misc.Wall StudsORCA.43056.001b Wall/Ceiling Sampled
12" x 12" Floor Tile, Beige, White Streaks Misc.FloorORCA.43056.002a Floor Sampled
Floor Tile Mastic, Yellow, Light Texture Misc.FloorORCA.43056.002b Floor Sampled
Covebase, Brown, Smooth Misc.WallORCA.43056.003a Wall Sampled
Covebase Mastic, Off White, Smooth Misc.WallORCA.43056.003b Wall Sampled
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43056.004a Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43057 - BLDG H2o Public
Resilient Sheet Flooring, Brown, Square Pattern Misc.FloorORCA.43057.001a Floor Sampled
Sheet Flooring Adhesive, Yellow, Stippled Misc.FloorORCA.43057.001b Floor Sampled
Roofing Felt, Black, Paper Misc.Roof DeckORCA.43057.002a Roof Sampled
Cave Junction, Oregon
November 17, 2011 Table 1.0 - Page 9 of 9
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43058 - BLDG H20 Maint Shop Area
Roofing Felt, Black, Concealed Misc.Roof DeckORCA.43058.001a Roof Assumed ACM
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 95025 - Duplex, Residence QMIS# 0000002 & 0000003
Resilient Sheet Flooring, Light Green, Gray Streaks Misc.FloorORCA.95025.001a Floor Sampled
Sheet Flooring Adhesive, Yellow, Smooth Misc.FloorORCA.95025.001b Floor Sampled
Wallboard, White Misc.Walls/CeilingsORCA.95025.002a Wall/Ceiling Sampled
Wallboard Joint Compound, White Misc.WallboardORCA.95025.003a Wall/Ceiling Sampled
Sink Drip Pad, Black Misc.SinkORCA.95025.004a Plumbing Fixtures Sampled
Roof Shingles, Black, Asphaltic Misc.Roof DeckORCA.95025.005a Roof Sampled
Roofing Felt, Black, Under Existing Finishes Misc.Roof DeckORCA.95025.006a Roof Sampled
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building UNKN2 - Shed-Maintenance
Roofing Felt, Black, Fibrous Misc.Roof DeckORCA.UNKN2.001a Roof Sampled
TABLE 2.0 - SUMMARY OF IDENTIFIED ACM
Cave Junction, Oregon
November 17, 2011 Table 2.0 - Page 1 of 2
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43034 - BLDG Chalet (hs) QMIS- 00000001
Friability
9" x 9" Floor Tile, Gray, Blue Streaks Misc.ConcreteORCA.43034.015a Floor SampledNon-Friable
Resilient Sheet Flooring, Brown, Stone Chip Pattern Misc.ConcreteORCA.43034.016a Floor SampledNon-Friable
Floor Tile Mastic, Black, Residual Misc.ConcreteORCA.43034.017a Floor SampledNon-Friable
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43045 - BLDG Chateau (hs)
Friability
Flange Gasket, Concealed Misc.Pipe FlangesORCA.43045.002a Fire Suppression Assumed ACMNon-Friable
Wallboard Joint Compound, White Misc.WallboardORCA.43045.004a Wall/Ceiling SampledNon-Friable
Fire Doors, Suspect Core Misc.Various ComponentsORCA.43045.007a Fire Suppression Assumed ACMNon-Friable
9" x 9" Floor Tile, Yellow, Red Streaks Misc.ConcreteORCA.43045.009a Floor SampledNon-Friable
9" x 9" Floor Tile, Light Brown, Multi-Colored Streaks
Misc.WoodORCA.43045.012a Floor SampledNon-Friable
Floor Tile Mastic, Black Misc.WoodORCA.43045.012b Floor SampledNon-Friable
12" x 12" Floor Tile, Green, Multi-Colored Streaks Misc.WoodORCA.43045.014a Floor SampledNon-Friable
12" x 12" Floor Tile, Beige, Multi-Colored Streaks Misc.WoodORCA.43045.015a Floor SampledNon-Friable
9" x 9" Floor Tile, Green/White, Checkerboard Misc.WoodORCA.43045.024a Floor SampledNon-Friable
Floor Tile Mastic, Black Misc.WoodORCA.43045.024b Floor SampledNon-Friable
9" x 9" Floor Tile, Green, Mottled Misc.WoodORCA.43045.025a Floor SampledNon-Friable
Floor Tile Mastic, Black Misc.WoodORCA.43045.025b Floor SampledNon-Friable
9" x 9" Floor Tile, White, Green Streaks Misc.WoodORCA.43045.027a Floor SampledNon-Friable
Resilient Sheet Flooring, Off White, Stone Chip Pattern
Misc.WoodORCA.43045.028a Floor SampledNon-Friable
TABLE 2.0 - SUMMARY OF IDENTIFIED ACM
Cave Junction, Oregon
November 17, 2011 Table 2.0 - Page 2 of 2
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43048 - BLDG Guide Shack(hs)
Friability
Wallboard Joint Compound, White, Smooth Misc.WallboardORCA.43048.001b Wall SampledNon-Friable
9" x 9" Floor Tile, Light Brown, White Streaks Misc.FloorORCA.43048.002a Floor SampledNon-Friable
Floor Tile Mastic, Black, Ridged Misc.FloorORCA.43048.002b Floor SampledNon-Friable
Resilient Sheet Flooring, Light Gray, Square Pattern Misc.FloorORCA.43048.003a Floor SampledNon-Friable
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43054 - BLDG Maint Shop
Friability
12" x 12" Floor Tile, Beige, Brown Streaks Misc.ConcreteORCA.43054.001a Floor SampledNon-Friable
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43055 - Residence # 5 Qmis # 00000005
Friability
Wallboard Joint Compound, White, Light Texture Misc.Walls/CeilingsORCA.43055.001b Wall/Ceiling SampledNon-Friable
Suspect Material Description Material Category
Associated Facility System
Homogeneous Material ID Substrate/Component
Suspect Material Classification
Building 43058 - BLDG H20 Maint Shop Area
Friability
Roofing Felt, Black, Concealed Misc.Roof DeckORCA.43058.001a Roof Assumed ACMNon-Friable
AAPPPPEENNDDIIXX AA
PPHHOOTTOOGGRRAAPPHHSS OOFF BBUUIILLDDIINNGGSS IINNCCLLUUDDEEDD IINN TTHHIISS SSUURRVVEEYY
APPENDIX A - BUILDING SUMMARY
Cave Junction, Oregon
November 17, 2011 Building Summary - Table of Contents
Building Building 43034 - BLDG Chalet (hs) QMIS- 00000001
Building 43037 - BLDG Ranger Cabin (hs) Building 43041 - BLDG Admin Hq Building
Building 43045 - BLDG Chateau (hs) Building 43048 - BLDG Guide Shack(hs)
Building 43050 - BLDG Kiosk (hs) Building 43052 - BLDG Tractor Shed
Building 43053 - BLDG Garage Building 43054 - BLDG Maint Shop
Building 43055 - Residence # 5 Qmis # 00000005 Building 43056 - BLDG Visitor Center Cave Junction
Building 43057 - BLDG H2o Public Building 43058 - BLDG H20 Maint Shop Area
Building 95025 - Duplex, Residence QMIS# 0000002 & 0000003 Building UNKN1 - HazMat
Building UNKN2 - Shed-Maintenance Building UNKN3 - Open Shed
Cave Junction, Oregon
November 17, 2011 Building Summary Page 1 of 9
Building Size: 10400 SF
ACM Identified
Construction Date: 1942
Building Use: BLDG Chalet (hs) QMIS- 00000001
Building 43034 - BLDG Chalet
(hs) QMIS- 00000001
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$3,952
$6,800
Building Size: 700 SF
ACM Not Identified In This Building
Construction Date: Unknown
Building Use: BLDG Ranger Cabin (hs)
Building 43037 - BLDG Ranger Cabin (hs)
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$266
$0
Cave Junction, Oregon
November 17, 2011 Building Summary Page 2 of 9
Building Size: 3800 SF
ACM Not Identified In This Building
Construction Date: 2005
Building Use: BLDG Admin Hq Building
Building 43041 - BLDG Admin Hq Building
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$1,444
$0
Building Size: 26000 SF
ACM Identified
Construction Date: 1934
Building Use: BLDG Chateau (hs)
Building 43045 - BLDG Chateau (hs)
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$9,880
$25,900
Cave Junction, Oregon
November 17, 2011 Building Summary Page 3 of 9
Building Size: 2700 SF
ACM Identified
Construction Date: 1926
Building Use: BLDG Guide Shack(hs)
Building 43048 - BLDG Guide Shack(hs)
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$1,026
$23,000
Building Size: 330 SF
ACM Not Identified In This Building
Construction Date: 1941
Building Use: BLDG Kiosk (hs)
Building 43050 - BLDG Kiosk (hs)
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$125
Cave Junction, Oregon
November 17, 2011 Building Summary Page 4 of 9
Building Size: 144 SF
ACM Not Identified In This Building
Construction Date: Unknown
Building Use: BLDG Tractor Shed
Building 43052 - BLDG Tractor Shed
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$55
$0
Building Size: 850 SF
ACM Not Identified In This Building
Construction Date: 1962
Building Use: BLDG Garage
Building 43053 - BLDG Garage
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$323
Cave Junction, Oregon
November 17, 2011 Building Summary Page 5 of 9
Building Size: 2500 SF
ACM Identified
Construction Date: Unknown
Building Use: BLDG Maint Shop
Building 43054 - BLDG Maint Shop
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$950
$1,500
Building Size: 1700 SF
ACM Identified
Construction Date: 1959
Building Use: Residence # 5 Qmis # 00000005
Building 43055 - Residence # 5 Qmis # 00000005
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$646
$44,000
Cave Junction, Oregon
November 17, 2011 Building Summary Page 6 of 9
Building Size: 1400 SF
ACM Not Identified In This Building
Construction Date: 1989
Building Use: BLDG Visitor Center Cave Junction
Building 43056 - BLDG Visitor Center Cave Junction
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$532
$0
Building Size: 165 SF
ACM Not Identified In This Building
Construction Date: Unknown
Building Use: BLDG H2o Public
Building 43057 - BLDG H2o Public
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$63
Cave Junction, Oregon
November 17, 2011 Building Summary Page 7 of 9
Building Size: 96 SF
ACM Assumed
Construction Date: Unknown
Building Use: BLDG H20 Maint Shop Area
Building 43058 - BLDG H20 Maint Shop Area
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$36
$1,500
Building Size: 2400 SF
ACM Not Identified In This Building
Construction Date: 2005
Building Use: Duplex, Residence QMIS# 0000002 & 0000003
Building 95025 - Duplex, Residence QMIS# 0000002 & 0000003
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$912
Cave Junction, Oregon
November 17, 2011 Building Summary Page 8 of 9
Building Size: 128 SF
No Suspect Materials Observed
Construction Date: Unknown
Building Use: HazMat
Building UNKN1 - HazMat
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$49
$0
Building Size: 96 SF
ACM Not Identified In This Building
Construction Date: Unknown
Building Use: Shed-Maintenance
Building UNKN2 - Shed- Maintenance
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$36
Cave Junction, Oregon
November 17, 2011 Building Summary Page 9 of 9
Building Size: 120 SF
No Suspect Materials Observed
Construction Date: Unknown
Building Use: Open Shed
Building UNKN3 - Open Shed
Previous Expense:
Current Expense:
Future Asbestos Clean-up Costs:
$0
$46
AAPPPPEENNDDIIXX BB
PPHHOOTTOOGGRRAAPPHHSS AANNDD SSUUPPPPLLEEMMEENNTTAALL IINNFFOORRMMAATTIIOONN FFOORR
NNOONN--AACCMM
APPENDIX B - NON-ACM DETAIL AND PHOTOGRAPHS
Building 43034 - Homogeneous Material ORCA-43034-001
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (001a) Resilient Sheet Flooring, Off White, Small Pattern Floor Tile Floor SampledORCA.43034.001a
(001b) Sheet Flooring Adhesive, Yellow, Smooth Floor Tile Floor SampledORCA.43034.001b (001c) 12" x 12" Floor Tile, Off White, Gray
Streaks Concrete Floor SampledORCA.43034.001c
(001d) Floor Tile Mastic, Rust, Smooth Concrete Floor SampledORCA.43034.001d
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Entry None Detected 001aB43034.047 Level 1 - Entry None Detected 001bB43034.047 Level 1 - Entry None Detected 001cB43034.047 Level 1 - Entry None Detected 001dB43034.047 Level 1 - Entry None Detected 001aB43034.048 Level 1 - Entry None Detected 001bB43034.048 Level 1 - Entry None Detected 001cB43034.048 Level 1 - Entry None Detected 001dB43034.048
Level 1 - Storage None Detected 001aB43034.049
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 1 of 84
Building 43034 - Homogeneous Material ORCA-43034-002
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (002a) 2' x 4' Ceiling Tile (Lay-in), White, Pindot Metal Grid Ceiling SampledORCA.43034.002a
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Womens Restroom None Detected 002aB43034.052 Level 1 - Womens Restroom None Detected 002aB43034.053
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 2 of 84
Building 43034 - Homogeneous Material ORCA-43034-003
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (003a) 2' x 4' Ceiling Tile (Lay-in), White, Pindot/Small Fissure Metal Grid Ceiling SampledORCA.43034.003a
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Entry None Detected 003aB43034.054 Level 1 - Entry None Detected 003aB43034.055
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 3 of 84
Building 43034 - Homogeneous Material ORCA-43034-004
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (004a) Resilient Sheet Flooring, Light Gray, Brick Pattern Concrete Floor SampledORCA.43034.004a
(004b) Sheet Flooring Adhesive, Clear, Smooth Concrete Floor SampledORCA.43034.004b
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Entry None Detected 004aB43034.050 Level 1 - Entry None Detected 004bB43034.050 Level 1 - Entry None Detected 004aB43034.051 Level 1 - Entry None Detected 004bB43034.051
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 4 of 84
Building 43034 - Homogeneous Material ORCA-43034-005
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (005a) Covebase, Brown, Smooth Wall Wall SampledORCA.43034.005a
(005b) Covebase Mastic, Brown, Stippled Wall Wall SampledORCA.43034.005b
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Entry None Detected 005aB43034.056 Level 1 - Entry None Detected 005bB43034.056 Level 1 - Entry None Detected 005aB43034.057 Level 1 - Entry None Detected 005bB43034.057
Level 1 - Storage None Detected 005aB43034.058 Level 1 - Storage None Detected 005bB43034.058
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 5 of 84
Building 43034 - Homogeneous Material ORCA-43034-006
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (006a) Plaster, White, Smooth Wallboard Wall SampledORCA.43034.006a
(006b) Plasterboard, Gray, Drilled Holes Wall Studs Wall SampledORCA.43034.006b
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Level 1 - Maintenance None Detected 006aB43034.059 Level 1 - Maintenance None Detected 006bB43034.059
Level 3 - Hallway None Detected 006aB43034.060 Level 3 - Hallway None Detected 006aB43034.061 Level 3 - Hallway None Detected 006bB43034.061 Level 2 - Bedroom None Detected 006aB43034.066
Level 2 - Mens Restroom None Detected 006aB43034.067 Level 2 - Meeting Room None Detected 006aB43034.068
Level 3 - Storage None Detected 006aB43034.069 Level 3 - Mens Restroom None Detected 006aB43034.070
Level 3 - Womens Restroom None Detected 006aB43034.071
Oregon Caves National Monument Cave Junction, Oregon
Non-ACM Detail Page 6 of 84
Building 43034 - Homogeneous Material ORCA-43034-007
Material Description Associated System Sampled/Assumed
Material Information
HM ID
Substrate/
Component (007a) Roofing Felt, Black, Paper Roof Deck Roof SampledORCA.43034.007a
HM # Sample Location Lab Results
Bulk Sample Data
Sample ID Roof None…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .