This document contains design drawings and specifications for the replacement of the well system serving the Peck Residence in Olympic National Park. The key details are:
The project involves construction and testing of a new potable water well, as well as installation of a new pump/treatment building. Key components include a new 60 sq. ft. pump house, a 1000-gallon septic tank and 450 sq. ft. drainfield, and electrical upgrades to the existing 200-amp service panel at the Peck Residence. The drawings provide specifications for the well, pump, water treatment equipment, and building construction. The project is solicited under Solicitation Number 140P8324Q0064 by the National Park Service's Pacific West Region. No specific award date or pricing terms are provided in the document.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P8324Q0064_Amd_0001.pdf | ||
| Attachment_E_Site_Visit_Clarifications_0001.pdf | ||
| Attachment_D_Forms_to_Return_with_Quote.docx | DOCX document | |
| Attachment_A_Specifications.pdf | ||
| Attachment_C__DOL_Wage_Determination.pdf | ||
| Sol_140P8324Q0064.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET SUB SHEET TITLE OF SHEET
1 G0 COVER SHEET
2 G1 GENERAL NOTES
3 G2 PROPERTY BOUNDARY MAP
4 G3 SITE PLAN
5 C1 DEMOLITION & SALVAGE
6 C2 PUMP HOUSE PLAN
7 C3 PROCESS FLOW DIAGRAM
8 C4 WELL SCHEMATIC
9 A1 FOUNDATION PLAN & SECTION
10 A2 PUMP HOUSE SECTION DETAIL
11 E1 ELECTRICAL SERVICE DETAILS
UNITED STATES
DEPARTMENT OF THE INTERIOR
TITLE OF PROJECT
REPLACE PECK RESIDENCE
WELL SYSTEM
DRAWING NO.
_149_
193,378
NATIONAL PARK SERVICE
OLYMPIC NATIONAL PARK
LOCATION WITHIN PARK
QUINAULT
PMIS/PKG NO.
338781
REGION COUNTY STATE
PACIFIC WEST GRAYS HARBOR WASHINGTON
SHEET
_1_ OF _11_
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH NPS STANDARDS AND
THE REQUIREMENTS OF CHAPTER 173-160 WASHINGTON ADMINISTRATIVE
CODE (IN ADDITION TO OTHER STATE AND LOCAL STANDARDS).
2. CONTRACTOR SHALL CONTACT DIG ALERT AND FIELD VERIFY ALL UTILITIES
PRIOR TO EXCAVATION. DIAL 811 BEFORE YOU DIG.
3. DIMENSIONS SHOWN ON PLANS ARE TO BE USED BY CONTRACTOR TO
DETERMINE APPROXIMATE FIELD CONDITIONS. PRIOR TO CONSTRUCTION,
CONTRACTOR SHALL FIELD VERIFY EXISTING LOCATIONS, ELEVATIONS,
MATERIAL TYPES, DIAMETER OF PIPES, ETC. OF ALL UTILITIES AND FEATURES
WHERE PROPOSED IMPROVEMENTS CONNECT. NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES IN WRITING.
4. EXISTING FACILITIES, INCLUDING BUT NOT LIMITED TO ROADS, SIDEWALKS,
STRUCTURES AND UTILITIES, DAMAGED BY CONTRACTOR’S OPERATIONS
SHALL BE RESTORED TO MATCH ORIGINAL PRE-CONSTRUCTION CONDITION
AND TO THE SATISFACTION OF THE CONTRACTING OFFICER WITHOUT
ADDITIONAL COST TO THE GOVERNMENT.
5. ALL DISTURBED ASPHALT, GRASS, DRAINAGE PATTERNS, ROADSIDE DITCHES,
TRAILS AND GRADE SHALL BE RESTORED TO ITS ORIGINAL CONDITION OR AS
CALLED FOR IN THE CONTRACT DOCUMENTS, WHICHEVER IS MORE
STRINGENT.
6. CONTRACTOR SHALL FURNISH AND INSTALL EVERYTHING REQUIRED TO
PROVIDE COMPLETE AND OPERABLE FACILITIES AS SHOWN HEREIN. IF THERE
IS AN OMISSION ON THE CONSTRUCTION DOCUMENTS, SUCH OMISSION
SHALL NOT BE CONSTRUED TO MEAN THAT THE CONTRACTOR IS NOT
REQUIRED TO FURNISH OR PROVIDE EVERYTHING THAT IS NECESSARY TO
PROVIDE COMPLETE AND OPERABLE FACILITIES.
7. ALL CONTRACTORS WORKING WITH THE PROJECT BOUNDARIES ARE
RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE SAFETY LAWS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL EMPLOYEES AND/OR
SUBCONTRACTORS WITH PERSONAL PROTECTIVE EQUIPMENT AND
FOLLOWING ALL SAFETY PROTOCOLS.
8. CONTRACTOR SHALL PROVIDE DETECTABLE LOCATOR TAPE FOR ALL BURIED
PIPE AND CONDUITS. BURY DEPTH SHALL BE 24” MINIMUM, UNLESS STATED
OTHERWISE.
9. ALL COSTS INCURRED IN CORRECTION OF DEFICIENT WORK SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
10. CONSTRUCTION FENCING OR BARRIERS SHALL BE PROVIDED WHERE
NECESSARY, INCLUDING AROUND OPEN EXCAVATIONS WHEN WORK IS NOT
ACTIVELY IN PROGRESS, TO PREVENT UNAUTHORIZED ACCESS.
11. UNLESS OTHERWISE INDICATED, DEMOLISHED MATERIALS BECOME THE
PROPERTY OF THE CONTRACTOR. COMPLY WITH EPA REGULATIONS AND
DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
12. MINIMIZE CONSTRUCTION IMPACTS TO SOILS, WATER, PLANTS, AND
ANIMALS, AND OTHER NATURAL RESOURCES DURING CONSTRUCTION.
CONFINE CONSTRUCTION OPERATIONS TO MINIMUM PRACTICAL AREA. IN NO
CASE SHALL CONSTRUCTION OPERATIONS EXTEND BEYOND LIMITS OF
CONSTRUCTION INDICATED WITHOUT PRIOR APPROVAL BY THE
CONTRACTING OFFICER.
DESIGNED:
K. COOK
SUB SHEET NO. TITLE OF SHEET
GENERAL NOTES
DRAWING NO.
_149_
193,378
TECH REVIEW:
G1
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_2_ OF _11_
DESIGNED:
K. COOK
SUB SHEET NO. TITLE OF SHEET
PROPERTY BOUNDARY MAP
DRAWING NO.
_149_
193,378
TECH REVIEW:
G2
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_3_ OF _11_
NOTES:
1. PARCEL NUMBER: 230903230030
2. SITE ADDRESS: 1031 NORTH SHORE
RD., AMANDA PARK, WA 98562
SCALE 1:3,049
NORTH SHORE ROAD
SUB SHEET NO. TITLE OF SHEET
SITE PLAN
DRAWING NO.
_149_
193,378
TECH REVIEW:
G3
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_4_ OF _11_
NOTES:
1. REMOVE 6 ALDER TREES (APPROXIMATELY
10-14” DBH) OVERHANGING NEW WELL
AND PUMP HOUSE SITE.
2. RETAIN RESIDENTIAL ACCESS AT ALL TIMES,
OR COORDINATE TEMPORARY ACCESS
LIMITATIONS WITH CONTRACTING OFFICER.
EXISTING WELL INSIDE 53 FT2
PUMP HOUSE (6’-5” X 8’-3”)
NEW 60 FT2
PUMP HOUSE
1200 FT2
PECK RESIDENCE
(25’ X 48’)
KESTNER CREEK
ASSUMED
CHLORINE CONTACT
PIPING
ASSUMED
WATER & DIRECT
BURY ELECTRICAL
CORRIDOR
PROTECT & RE-USE
WATER LINE; INSTALL
NEW ELECTRICAL
CONDUIT & WIRE
NEW WELL
DEMOLISH &
DECOMMISSION
CONSTRUCT
1000-GALLON SEPTIC
TANK & 450 FT2
DRAINFIELD
DRIVEWAY /
ACCESS ROAD
LIMITS OF
CONSTRUCTION
& CONTRACTOR
STAGING AREA WOODSHED &
STORAGE SHED
INSTALL NEW
ELECTRICAL CONDUIT
& CONDUCTOR WIRE,
REPLACE 30 AMP
BREAKER IN 200 AMP
PANEL FOR NEW
PUMP HOUSE
SUB SHEET NO. TITLE OF SHEET
DEMOLITION & SALVAGE
DRAWING NO.
_149_
193,378
TECH REVIEW:
C1
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_5_ OF _11_
NOTES:
1. PROTECT & CONNECT TO CHLORINE CONTACT PIPING (LOCATED NEAR BACK LEFT CORNER OF BUILDING) FOR EXTENSION TO NEW PUMP HOUSE
BUILDING SITE. INSTALL NEW ELECTRICAL CONDUIT BETWEEN NEW PUMP HOUSE AND RESIDENCE. REPLACE 30 AMP “BARN” CIRCUIT BREAKER ON 200 AMP SERVICE PANEL WITH NEW 30 AMP BREAKER & CONDUCTOR WIRE TO NEW 100 AMP PUMP HOUSE SUBPANEL.
2. SALVAGE AND TRANSFER TO GOVERNMENT EXISTING DOOR HARDWARE, CHEMICAL FEED PUMP, SODIUM HYPOCHLORITE, AND TERMINATOR IRON FILTER WITH FLECK 2510 CONTROL VALVE WATER TREATMENT COMPONENTS PRIOR TO BUILDING DEMOLITION.
3. DEMOLISH & DISPOSE OF EXISTING PUMP HOUSE, CONCRETE PADS, AND REMAINING COMPONENTS. DECOMMISSION WELL.
EXISTING 53 FT2 PUMP HOUSE (6’-5” X 8’-3”) PECK RESIDENCE 200 AMP SERVICE PANELEXISTING WELL & TREATMENT COMPONENTS
SUB SHEET NO. TITLE OF SHEET
PUMP HOUSE PLAN
DRAWING NO.
_149_
193,378
TECH REVIEW:
C2
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_6_ OF _11_
BYPASS VALVE
& AIR INJECTOR
WITH UNIONS
PRESSURE
RELIEF VALVE
PRESSURE
TANK
PRESSURE
SWITCH &
TANK DRAIN
AIR CONTACT
TANK WITH
AIR VENT
¾” BACKWASH
LINE TO EXTERIOR
DRAIN POINT
HOSE BIB
SAMPLE TAP
& PRESSURE
GAUGE
CHECK
VALVE
BALL
VALVE
IRON FILTER
WITH BACKWASH
CONTROL VALVE
CHEMICAL
METERING
PUMP (ON
SHELF) &
INJECTION
QUILL
SCALE OF FEET
4 0 4 8
FROM
NEW WELL
3’
10’
6’
TO EXISTING
CHLORINE
CONTACT PIPING
WELL PUMP
CONTROLLER
110V
GFCI
LIGHT
SWITCH
110V
GFCI
NOTES:
1. PUMP HOUSE PLAN IS SCHEMATIC; PROVIDE
ALL COMPONENTS NECESSARY FOR A FULLY
FUNCTIONING SYSTEM.
2. ALL COMPONENTS IN CONTACT WITH
DRINKING WATER SHALL BE NSF 61
CERTIFIED.
3. ALL PLUMBING SHALL BE 1” PEX, PVC, OR
BRASS UNLESS OTHERWISE NOTED.
4. WELL PUMP & CONTROLLER SHALL BE
FRANKLIN ELECTRIC, OR APPROVED EQUAL.
5. PRESSURE TANK SHALL BE AMTROL WELL-X-
TROL 200 SERIES, OR APPROVED EQUAL.
6. IRON FILTER SHALL BE TERMINATOR WITH
FLECK CONTROL VALVE AND AIR TANK WITH
HONEYWELL AIR VENT, OR APPROVED
EQUAL.
7. SODIUM HYPOCHLORITE CHEMICAL
METERING PUMP SHALL BE WALCHEM E-
CLASS BY IWAKI, OR APPROVED EQUAL.
8. FLUSH ENTRANCE DOOR SHALL BE FACTORY
PRIMED FIBERGLASS WITH INSULATED CORE
& STAINLESS HARDWARE. INCLUDE LEVER
AND SFIC 6 OR 7 PIN CORE/LOCKSET
COMPATIBLE WITH BEST ACCESS KEY
SYSTEM, BEST 9K37AB15D53626, OR
APPROVED EQUAL.
9. FURNISH AND INSTALL PLYWOOD SHELF FOR
CHEMICAL METERING PUMP.
10. ENSURE WATER TREATMENT COMPONENTS
ARE POWERED BY A RECEPTACLE THAT IS
ONLY ENERGIZED WHEN WELL PUMP IS
RUNNING.
LED OVERHEAD LIGHT
BALL
VALVE
100 AMP
LOAD CENTER
FIBERGLASS
DOOR
5’ X 5’ CONCRETE PAD
(2% SLOPE TO DRAIN)
HOSE BIB
SAMPLE TAP
& PRESSURE
GAUGE
SUB SHEET NO. TITLE OF SHEET
PROCESS FLOW DIAGRAM
DRAWING NO.
_149_
193,378
TECH REVIEW:
C3
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_7_ OF _11_
¾”
SODIUM
HYPOCHLORITE
SODIUM
HYPOCHLORITE
SUB SHEET NO. TITLE OF SHEET
WELL SCHEMATIC
DRAWING NO.
_149_
193,378
TECH REVIEW:
C4
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_8_ OF _11_
NOTES:
1. WELL CAP SHALL BE WATER-TIGHT
REMOVABLE CAST-IRON BLANK WELL
SEAL SIZED FOR WELL CASING,
CAMPBELL MANUFACTURING OR
APPROVED EQUAL.
2. WELL PUMP SHALL BE FRANKLIN
ELECTRIC SUBMERSIBLE WELL PUMP,
OR APPROVED EQUAL.
3. PITLESS ADAPTOR AND WATER SHALL
BE 18” MINIMUM BELOW GRADE.
4. WIRE IN CONDUIT SHALL BE 18”
MINIMUM BELOW GRADE FROM
WELL TO PUMP HOUSE.
5. TORQUE ARREST SHALL BE INSTALLED
WITHIN 2 FEET OF PUMP DISCHARGE.
6. CHECK VALVE SHALL BE INSTALLED 20
FEET ABOVE PUMP DISCHARGE.
SUB SHEET NO. TITLE OF SHEET
FOUNDATION PLAN & SECTION
DRAWING NO.
_149_
193,378
TECH REVIEW:
A1
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_9_ OF _11_
10’-0”
9’-5”
3½” STEM WALL
3’-6”
4” CONCRETE SLAB
W/ 6X6 W2.1 X
W2.1 WELDED
WIRE MESH
4” CONCRETE SLAB
W/ 6X6 W2.1 X
W2.1 WELDED
WIRE MESH
NOTE: INSTALL
UFER GROUNDING
AT LOCATION OF
ELECTRICAL PANEL
SLEEVES &
STUB-UPS
FOR WATER &
ELECTRICAL
OPENING FOR
DOOR FRAME
5’-0”
6’-0”
5’-0”
#4 VERT. TYP.
SCALE OF FEET
4 0 4 8
FOUNDATION PLAN
NOTES:
1. CONCRETE AT 3,000 PSI.
SUB SHEET NO. TITLE OF SHEET
PUMP HOUSE SECTION DETAIL
DRAWING NO.
_149_
193,378
TECH REVIEW:
A1
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_10_ OF _11_
NOTES:
1. STANDING SEAM PANEL METAL
ROOFING W/ HIGH TEMP SELF-
ADHERED ICE & WATER PROTECTION
UNDERLAYMENT; 26-GA CONCEALED
FASTENER STANDING SEAM
(CHAMPION METAL “SNAP-LOC” OR
EQUAL) STYLE ROOFING PANELS AND
ASSOCIATED FLASHING/TRIM/RIDGE
CAP IN “WEATHERED COPPER”
COLOR. ALL FASTENERS TO BE 304
STAINLESS, MINIMUM. VENT VIA
SCREENED BLOCKING AND RIDGE
VENTS.
2. INSTALL ONE ANSI 359.1 D-RING
RIDGE ANCHOR AT CENTER OF RIDGE.
3. ½” CDX PLYWOOD AT WALLS AND
CEILING.
4. PAINT EXTERIOR WITH ACRYLIC
EXTERIOR PAINT, COLOR
BEECHWOOD. PAINT FASCIA AND
DOOR TRIM GREEN GOLD TO MATCH
EXISTING PUMP HOUSE AND PECK
RESIDENCE COLOR SCHEME.
5. INCLUDE TWO SCREENED WALL
VENTS ON SOUTH OR WEST WALL,
SIMILAR TO EXISTING PUMP HOUSE.
FIBER CEMENT
PANEL W/ REVERSE
BATTEN
3-½” MINERAL INSULATION
2 X 4 CONSTRUCTION
2 X 4 PRESSURE TREATED PLATE
SILL PLATE GASKET
BROWN PAINTED
ALUMINUM FLASHING
HOUSE WRAP
2 LAYERS 3-½” MINERAL INSULATION
½” CDX PLYWOOD. PAINT ONE COAT PRIMER THEN 2 TOP COATS
OF WHITE IN SATIN/EGGSHELL
BASIS OF DESIGN: RODDA UNIQUE II ACRYLIC LATEX PAINT, OR
APPROVED EQUAL (INTERIOR & EXTERIOR)
HOLDOWN AT LOCATIONS PER CODE
ANCHOR BOLT MIN. 7” IN CONCRETE
#4 HORIZONTAL
SUB SHEET NO. TITLE OF SHEET
ELECTRICAL SERVICE DETAILS
DRAWING NO.
_149_
193,378
TECH REVIEW:
E1
PECK RESIDENCE WELL SYSTEM PMIS/PKG NO.
338781
DATE:
5/2024
QUINAULT, WA
OLYMPIC NATIONAL PARK
SHEET
_11_ OF _11_
PECK RESIDENCE 200 AMP SERVICE PANEL
NOTES:
1. REPLACE EXISTING 30 AMP BREAKER
INSIDE PECK RESIDENCE 200 AMP
SERVICE PANEL.
2. REPLACE EXISTING DIRECT BURY WIRE
WITH NEW CONDUIT AND
CONDUCTOR WIRE TO FEED NEW 100
AMP SUBPANEL IN NEW PUMP
HOUSE.
PECK RESIDENCE ELECTRICAL SERVICE METER
| Slide Number 1 |
| GENERAL NOTES |
| Slide Number 3 |
| Slide Number 4 |
| Slide Number 5 |
| Slide Number 6 |
| Slide Number 7 |
| Slide Number 8 |
| Slide Number 9 |
| Slide Number 10 |
| Slide Number 11 |
File details come from the government source that posted it. Updated .