Attach_2_-_Drawings_HVAC_and_Roof.pdf

PDF 8 MB Posted

Attached to
Replace Alan Bible Visitor Center HVAC and Roof
Solicitation number
140P8124B0002
Issued by

About this file

This document contains construction drawings related to the replacement of the HVAC system and roof at the Alan Bible Visitor Center at Lake Mead National Recreation Area in Boulder City, Nevada. The drawings include a roof demolition plan, roof plan, and various roof details. The key scope of work includes:

  • Replace rooftop HVAC units AC-2, AC-3, and AC-4
  • Replace exhaust fans EF-1 and RF-2
  • Replace split system fan coil/condensing units FC/CU-4, 5, 6, and 7
  • Replace ductwork and diffusers serving office and basement spaces
  • Reconfigure lobby supply and return ductwork
  • Provide supply air to restrooms from AC-2
  • Remove and replace the entire roof system including membrane, insulation, and flashing

The drawings also include structural details for patching existing roof openings and framing new openings. This appears to be part of a larger federal solicitation to replace the HVAC and roof at the Alan Bible Visitor Center.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET INDEX

04/26/2023 04/26/202304/28/2023

ENGINEER RESPONSIBLE FOR

MECHANICAL DRAWINGS:

ENGINEER RESPONSIBLE FOR

ELECTRICAL DRAWINGS:

ENGINEER RESPONSIBLE FOR

STRUCTURAL DRAWINGS:

SHEET INDEX

PAGE NO. SHEET NO. SHEET TITLE

ARCHITECTURAL

25 A0.0 LEGEND & ABBREVIATIONS

26 A0.1 GENERAL NOTES

27 A1.0 ROOF DEMOLITION PLAN

28 A1.1 ROOF PLAN

29 A5.0 ROOF DETAILS

30 A5.1 ROOF DETAILS

31 A5.2 ROOF DETAILS

32 A5.3 ROOF DETAILS

PMIS#228968 (ABVC HVAC)

PMIS#334958 (ABVC ROOF)

REPLACE ABVC HVAC AND ROOF

AutoCAD SHX Text

INDIAN

AutoCAD SHX Text

CALIFORNIA

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

AutoCAD SHX Text

COVE

AutoCAD SHX Text

SEARCHLIGHT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

COTTONWOOD

AutoCAD SHX Text

NELSON

AutoCAD SHX Text

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

BULLHEAD CITY

AutoCAD SHX Text

LAUGHLIN

AutoCAD SHX Text

DAVIS

AutoCAD SHX Text

DAM

AutoCAD SHX Text

AutoCAD SHX Text

KATHERINE

AutoCAD SHX Text

MOHAVE

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

AutoCAD SHX Text

CANYON

AutoCAD SHX Text

ELDORADO

AutoCAD SHX Text

ARIZONA

AutoCAD SHX Text

SPRINGS

AutoCAD SHX Text

DOLAN

AutoCAD SHX Text

HUALAPAI

AutoCAD SHX Text

TO ST. GEORGE, UTAH

AutoCAD SHX Text

PARK

AutoCAD SHX Text

DAM

AutoCAD SHX Text

HOOVER

AutoCAD SHX Text

FIRE STATE

AutoCAD SHX Text

VALLEY OF

AutoCAD SHX Text

BLUE POINT SPRING

AutoCAD SHX Text

ROGERS SPRING

AutoCAD SHX Text

BEACH

AutoCAD SHX Text

BOULDER

AutoCAD SHX Text

AutoCAD SHX Text

TO

AutoCAD SHX Text

CALIFORNIA

AutoCAD SHX Text

LAS VEGAS

AutoCAD SHX Text

ANGELES,

AutoCAD SHX Text

LOS

AutoCAD SHX Text

TO

AutoCAD SHX Text

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

RENO,

AutoCAD SHX Text

HENDERSON

AutoCAD SHX Text

BOULDER CITY

AutoCAD SHX Text

AutoCAD SHX Text

HQ.

AutoCAD SHX Text V.C.

AutoCAD SHX Text

LAS VEGAS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WASH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

BAY

AutoCAD SHX Text

CALLVILLE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ECHO

AutoCAD SHX Text

BAR

AutoCAD SHX Text

BEACH

AutoCAD SHX Text

WILLOW

AutoCAD SHX Text

GREGGS

AutoCAD SHX Text

HIDEOUT

AutoCAD SHX Text

MEAD

AutoCAD SHX Text

LANDING

AutoCAD SHX Text

BONELLI

AutoCAD SHX Text

REDSTONE

AutoCAD SHX Text

AutoCAD SHX Text

TEMPLE

AutoCAD SHX Text

BAY

AutoCAD SHX Text

COVE

AutoCAD SHX Text

MEADVIEW

AutoCAD SHX Text

GRAND

AutoCAD SHX Text

FERRY

AutoCAD SHX Text

PEARCE

AutoCAD SHX Text

SOUTH

AutoCAD SHX Text

OVERTON

AutoCAD SHX Text

AutoCAD SHX Text

OVERTON

AutoCAD SHX Text

BEACH

AutoCAD SHX Text

ARIZONA

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

COLORADO

AutoCAD SHX Text

CREEK

AutoCAD SHX Text

PARK

AutoCAD SHX Text

RESERVATION

AutoCAD SHX Text

DIAMOND

AutoCAD SHX Text

RIVER

AutoCAD SHX Text

TO

AutoCAD SHX Text

WHITMORE

AutoCAD SHX Text

CANYON

AutoCAD SHX Text

NATIONAL

AutoCAD SHX Text

CANYON

AutoCAD SHX Text

PLATEAU

AutoCAD SHX Text

SHIVWITS

AutoCAD SHX Text

AutoCAD SHX Text

CITY

AutoCAD SHX Text

BULLHEAD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NATIONAL

AutoCAD SHX Text

NATIONAL

AutoCAD SHX Text

PARK

AutoCAD SHX Text

AutoCAD SHX Text

PRESCOTT

AutoCAD SHX Text

CITY

AutoCAD SHX Text

HAVASU

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

AutoCAD SHX Text

KINGMAN

AutoCAD SHX Text

RECREATION

AutoCAD SHX Text

AutoCAD SHX Text

AREA

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

FLAGSTAFF

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WINSLOW

AutoCAD SHX Text

CANYON

AutoCAD SHX Text

GRAND

AutoCAD SHX Text

PAGE

AutoCAD SHX Text

AutoCAD SHX Text

CANYON

AutoCAD SHX Text

UTAH

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

AutoCAD SHX Text

LAKE MEAD

AutoCAD SHX Text

AutoCAD SHX Text

ARIZONA

AutoCAD SHX Text

UTAH

AutoCAD SHX Text

LAKE

AutoCAD SHX Text

JACOB

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N.R.A.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GLEN

AutoCAD SHX Text

AutoCAD SHX Text

LAKE MEAD

AutoCAD SHX Text

NATIONAL RECREATION AREA

AutoCAD SHX Text

PARK HEADQUARTERS

AutoCAD SHX Text

PAVED ROAD

AutoCAD SHX Text

HQ.

AutoCAD SHX Text

STATE LINE

AutoCAD SHX Text

COUNTY LINE

AutoCAD SHX Text

PARK BOUNDARY

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

LOCATION OF SITE

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

LOCATION WITHIN STATE

AutoCAD SHX Text

STATE

AutoCAD SHX Text

NATIONAL PARK SERVICE

AutoCAD SHX Text

DENVER SERVICE CENTER

AutoCAD SHX Text

REGION

AutoCAD SHX Text

COUNTY

AutoCAD SHX Text

DEPARTMENT OF THE INTERIOR

AutoCAD SHX Text

NAME OF PARK

AutoCAD SHX Text

UNITED STATES

AutoCAD SHX Text

LOCATION WITHIN PARK

AutoCAD SHX Text

TITLE OF PROJECT

AutoCAD SHX Text

PKG.

AutoCAD SHX Text

OF

AutoCAD SHX Text

NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text 22/01/2019 11:16 JENNIFER CHEEK G:\CLIENTS\NPS\LAKE\228968\DRAWINGS\GEN\1 COVER SHEET.DWG

AutoCAD SHX Text

PMIS#228968

AutoCAD SHX Text

CONSTRUCTION DRAWINGS

AutoCAD SHX Text

REPLACE ALAN BIBLE VISITOR CENTER HVAC

AutoCAD SHX Text

ALAN BIBLE VISITOR CENTER

AutoCAD SHX Text

LAKE MEAD

AutoCAD SHX Text

PACIFIC WEST

AutoCAD SHX Text

CLARK

AutoCAD SHX Text

NEVADA

AutoCAD SHX Text

AutoCAD SHX Text 25005A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text

PAGE NO.

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

GENERAL

AutoCAD SHX Text

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text G0.0

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL GENERAL NOTES AND LEGEND

AutoCAD SHX Text M0.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL BASEMENT DEMOLITION PLAN

AutoCAD SHX Text M1.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL FIRST FLOOR DEMOLITION PLAN

AutoCAD SHX Text M1.1

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL ROOF DEMOLITION PLAN

AutoCAD SHX Text M1.2

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL BASEMENT FLOOR PLAN

AutoCAD SHX Text M2.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL FIRST FLOOR PLAN

AutoCAD SHX Text M2.1

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL ROOF PLAN

AutoCAD SHX Text M2.2

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL DETAILS

AutoCAD SHX Text M5.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL DETAILS

AutoCAD SHX Text M5.1

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL SCHEDULES

AutoCAD SHX Text M6.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text M7.0

AutoCAD SHX Text

AutoCAD SHX Text

MECHANICAL CONTROLS

AutoCAD SHX Text M7.1

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL COVER SHEET

AutoCAD SHX Text E0.0

AutoCAD SHX Text

AutoCAD SHX Text

BASEMENT ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text E1.0

AutoCAD SHX Text

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text E1.1

AutoCAD SHX Text

AutoCAD SHX Text

ROOF ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text E1.2

AutoCAD SHX Text

AutoCAD SHX Text

BASEMENT ELECTRICAL PLAN

AutoCAD SHX Text E2.0

AutoCAD SHX Text

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL PLAN

AutoCAD SHX Text E2.1

AutoCAD SHX Text

AutoCAD SHX Text

ROOF ELECTRICAL PLAN

AutoCAD SHX Text E2.2

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL SINGLE LINE DIAGRAM

AutoCAD SHX Text E3.0

AutoCAD SHX Text

AutoCAD SHX Text

SCHEDULES

AutoCAD SHX Text E3.1

AutoCAD SHX Text

STRUCTURAL

AutoCAD SHX Text

AutoCAD SHX Text

STRUCTURAL NOTES

AutoCAD SHX Text S0.0

AutoCAD SHX Text

AutoCAD SHX Text

STRUCTURAL DETAILS

AutoCAD SHX Text S1.0

FIN

AL D

RAFT

PIPE SIZE

CONDENSATE DRAIN

REFRIGERANT LIQUID

REFRIGERANT SUCTION

REFRIGERANT VENT

PIPING SYSTEMS (HVAC)

2 1/2"

CWR

REF(L)

REF(S)

REF(V)

FCU

NEW WORK

EXISTING (E)

DEMO EXISTING (X)

KEY NOTE

EQUIPMENT IDENTIFICATION

WORK DEFINITION

UP

DN

BDD

M

UC

T

AIR FLOW ARROW

RECTANGULAR DUCT AND SIZE*

ROUND DUCT AND SIZE*

FLAT OVAL DUCT AND SIZE*

EXTERIOR DUCT TREATMENT*

RECTANGULAR DUCT WITH ACOUSTIC LINING*

DUCT SECTION, SUPPLY AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, RETURN AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, EXHAUST AIR. APPLIES TO RECT., ROUND AND OVAL

FLEXIBLE DUCT

ELBOW TURN, SUPPLY DOWN. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL

DUCT SECTION, OUTSIDE AIR. APPLIES TO RECT., ROUND AND OVAL

CHANGE IN DUCT ELEVATION RISING IN DIRECTION INDICATED

CHANGE IN DUCT ELEVATION DROPPING IN DIRECTION INDICATED

END CAP

ELBOW, RECTANGULAR, SMOOTH RADIUS WITH SPLITTER VANES

(0.25 R/W DEFAULT)

ELBOW, RECTANGULAR, SMOOTH RADIUS WITHOUT VANES

(1.5 R/W DEFAULT)

ELBOW, ROUND, SMOOTH RADIUS

(1.5 R/W DEFAULT)

MITERED ELBOW, RECTANGULAR, WITH TURNING VANES

RECTANGULAR TO ROUND TRANSITION

DUCT ACCESS DOOR(TOP,SIDE,BOTTOM)

FLEXIBLE CONNECTION

BACKDRAFT DAMPER

MANUAL DAMPER

MOTORIZED DAMPER

FIRE DAMPER

SMOKE DAMPER

SMOKE AND FIRE DAMPER

DUCT SILENCER

CONTROL DEVICE (REFER TO CONTROLS LEGEND)

AIR FLOW MEASURING STATION (REFER TO CONTROLS LEGEND)

QUANTITY

TYPE

AIR OUTLET OR INLET TAG (REFER TO SCHEDULE)SIZE (IN.)

VOLUME (CFM)

RECTANGULAR DIFFUSER, SUPPLY.

OPTIONAL ARROWS SHOW THE FLOW DIRECTION.

RECTANGULAR REGISTER OR GRILLE RETURN

RECTANGULAR REGISTER OR GRILLE, EXHAUST

ROUND DIFFUSER, SUPPLY

LINEAR DIFFUSER

SIDEWALL REGISTER OR GRILLE, SUPPLY

SIDEWALL GRILLE, RETURN OR EXHAUST

UNDERCUT DOOR

DOOR GRILLE OR LOUVER

TRANSFER GRILLE OR LOUVER

COIL (REFER TO CONTROLS LEGEND)

QUANTITY

TYPE

LENGTH (FT.)

RADIATION HEATING TAG (REFER TO SCHEDULE)

CAPACITY (MBH)

18"x12" 18"x12"

18"x12" 18"x12" 18"x12"

18"x12"ø 18"x12"ø 18"ø 18"ø

30"x12"

*NOTE: ALL DUCT SIZES ARE INTERIOR, FREE DIMENSIONS

ALWAYS WIDTH (HORIZONTAL DIM.) x HEIGHT (VERTICAL DIM.)

VENTILATION (HVAC)

PROJECT

NORTH

TRUE

NORTH

1. CONTRACTOR SHALL VISIT SITE TO REVIEW SCOPE OF WORK PRIOR

TO SUBMISSION OF BID

2. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND ARE

BASED ON ONE MANUFACTURER'S EQUIPMENT. THEY ARE NOT

INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE

EXACT DIMENSIONS, OR ALL OF THE DETAILS FOR THE EQUIPMENT.

THE HVAC CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS

OF THE EQUIPMENT AND ENSURE THAT IT WILL FIT IN THE AVAILABLE

SPACE AND THAT PROPER MAINTENANCE CLEARANCES ARE

ACHIEVED.

3. MECHANICAL CONTRACTOR RESPONSIBLE FOR INSTALLATION OF

COMPLETED AND OPERATIONAL SYSTEMS WITH DUE RESPECT TO

ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION.

4. IT IS THE CONTRACTOR RESPONSIBILITY TO FIELD VERIFY ALL

CONNECTION POINTS PRIOR TO INSTALL. NOT ALL CONNECTION

SIZES ARE SHOWN, BUT THOSE THAT ARE APPROXIMATE AND TAKEN

FROM EXISTING AS-BUILTS AND FIELD OBSERVATIONS.

5. COORDINATE PIPE ROUTING WITH DUCTWORK, SPRINKLER PIPING

AND ELECTRICAL POWER/LIGHTING CIRCUITING AND STRUCTURAL

MEMBERS PRIOR TO INSTALLATION

6. ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND

ORDINANCES INCLUDING NEVADA STATE RULES AND REGULATIONS.

7. CONTRACTORS TO VERIFY ALL GRADES, DIMENSIONS AND EXISTING

CONDITIONS AT THE SITE BEFORE PROCEEDING WITH WORK.

NOTIFY PRIME CONSULTANT OF ANY DISCREPANCIES BETWEEN

DRAWINGS AND ACTUAL CONDITIONS BEFORE INSTALLATION.

8. ALL MATERIALS AND INSTALLATION SHALL COMPLY WITH THE

NATIONAL PARK SERVICE CONSTRUCTION SPECIFICATIONS.

9. COORDINATE INSTALLATION OF PIPING AND DUCTWORK WITH

ELECTRICAL CONTRACTOR AND OTHER TRADES.

10. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS NEEDED TO

CONSTRUCT WORK IN THE CONSTRUCTION DOCUMENTS AND

ACCOMPANYING SPECIFICATIONS

11. IF THERE IS A CONFLICT BETWEEN THE CONSTRUCTION

DOCUMENTS AND SPECIFICATIONS, THE MOST STRINGENT WILL

APPLY.

12. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH

THE EQUIPMENT MANUFACTURERS. CONTRACTOR TO PROVIDE ALL

FITTINGS,TRANSITIONS, DAMPERS, VALVES, AND OTHER DEVICES

REQUIRED FOR A COMPLETE WORKABLE INSTALLATION.

13. PENETRATIONS OF DUCTS, PIPES, CONDUITS,ETC IN WALLS

REQUIRING PROTECTED OPENINGS SHALL BE FIRE STOPPED, FIRE

STOP MATERIAL, SHALL BE A UL-LISTED ASSEMBLY APPROPRIATE

FOR FIRE OR SMOKE PENETRATIONS AS APPLICABLE AND AS

APPROVED BY THE FIRE MARSHAL.

14. THE HVAC CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED

FIRE DAMPERS AND ACCESS PANELS IN ALL DUCTWORK THAT

PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS

OTHERWISE SHOWN ON THE DRAWINGS.

15. ALL BRANCH DUCTS HAVE VOLUME DAMPERS.

16. WHERE FLOW EXCEEDS 150 CFM, THE CONTRACTOR SHALL USE

SMOOTH RADIUS ELBOWS OR TURNING VANES.

17. ALL DUCT JOINTS SHALL BE SEALED IN ACCORDANCE WITH SMACNA

STANDARDS AND ACCEPTED GOOD PRACTICE.

18. ALL DUCT DIMENSIONS ARE NET INSIDE VALUES. DIMENSIONS MAY

BE CHANGED PROVIDED THAT THE NET FREE AREA IS MAINTAINED.

19. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1"

FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING.

20. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED AND TESTED IN

ACCORDANCE WITH THE LOCAL REGULATIONS AND PROCEDURES

DETAILED IN THE APPLICABLE STANDARDS ADOPTED BY THE SHEET

METAL AND AIR CONDITIONING CONTRACTORS NATIONAL

ASSOCIATION. (SMACNA).

21. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN

A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL

STRAPS TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF

PIPE SUPPORTS SHALL NOT EXCEED 8 FEET FOR ALL PIPING.

PLASTIC PIPING SHALL BE SUPPORTED EVERY 4 FEET.

22. THE HVAC SYSTEMS SHALL BE TESTED AND BALANCED BY AN

INDEPENDENT AGENCY, UNDER THE SUPERVISION OF A LICENSED

PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL

BE SUBMITTED TO THE ARCHITECT/ENGINEER.

23. ALL EQUIPMENT TO BE INSTALLED ON MIN 6" CURBS.

24. ALL EQUIPMENT, DUCTS PIPING, AND OTHER DEVICES AND

MATERIALS INSTALLED OUTSIDE OF THE BUILDING OR OTHERWISE

EXPOSED TO THE WEATHER SHALL BE COMPLETELY

WEATHERPROOFED.

1. THE CONTRACTOR SHALL VISIT THE SITE AND BE THOROUGHLY

FAMILIARIZED WITH THE EXISTING CONDITIONS PRIOR TO BIDDING.

INFORMATION GIVEN ON THESE DRAWINGS ABOUT THE EXISTING

INSTALLATION HAS BEEN OBTAINED FROM THE EXISTING AS-BUILT

DRAWINGS BUT CANNOT BE GUARANTEED ACCURATE IN ALL

RESPECTS. VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING

WITH ANY NEW WORK THAT MAY BE AFFECTED. INCLUDE AS PART

OF THE CONTRACT ALL WORK REQUIRED TO PRODUCE THE

INDICATED RESULT.

2. UPON SUBMITTING A BID THE CONTRACTOR SHALL BE HELD TO

HAVE MADE SUCH EXAMINATIONS OF THE SITE AND NO ALLOWANCE

FOR EXTRAS WILL BE ALLOWED FOR ANY ERROR OR OVERSIGHT

RESULTING FORM THE CONTRACTOR'S UNFAMILIARITY WITH THE

SITE OR EXISTING CONDITIONS.

3. CONTRACTOR SHALL NOT SCALE DRAWINGS. DIMENSIONS MISSING

FROM PLANS OR NEEDED FOR EXECUTION OF WORK SHALL BE

CLARIFIED OR PROVIDED BY THE FACILITY REPRESENTATIVE

BEFORE WORK IS INSTALLED.

4. INTERRUPTION OF EXISTING SERVICES: THE CONTRACTOR'S

ATTENTION IS CALLED TO THE PRESENCE OF EXISTING, CONDUIT,

PIPING, ETC. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR

THE PROPER AND APPROVED REPAIR OF ANY AND ALL DAMAGE

CAUSED BY THEM OR THEIR WORK TO EXISTING BUILDING. THE

BUILDING IS A HISTORIC STRUCTURE AND ANY DAMAGE MUST BE

REPAIRED TO MATCH COLOR AND MATERIALS OF THE EXISTING

BUILDING. ANY INTERRUPTIONS REQUIRED SHALL BE SCHEDULED

TO MINIMIZE INCONVENIENCE TO THE FACILITY, AND AT TIMES AS

APPROVED IN ADVANCE BY THE FACILITY REPRESENTATIVE. NEW

WORK AND INSTALLATIONS SHALL NOT IMPAIR THE PROPER

FUNCTIONING OF THE EXISTING FACILITY. THE COMPLETED

PROJECT SHALL BE A PROPERLY FUNCTIONING ENTITY

THROUGHOUT. FURNISH ALL LABOR AND MATERIALS REQUIRED TO

RELOCATE, REMOVE, REINSTALL, RECONNECT, REPLACE, ANY

EXISTING PIPING TO ACCOMMODATE THE WORK. CONTRACTOR

SHOULD CONSIDER IN THEIR BID ANY EXTRA WORK REQUIRED TO

MINIMIZE SHUTDOWN TIME.

5. EQUIPMENT FIXTURE, PIPING ETC. THAT ARE TO BE

REMOVED/DEMOLISHED SHALL BE THE PROPERTY OF THIS

CONTRACTOR UNLESS NOTED FOR SALVAGE BY FACILITY AND

SHALL BE REMOVED IN ITS ENTIRELY FROM THE PREMISES.

6. BEFORE DEMOLITION COMMENCES ON SITE, ALL EXISTING

EQUIPMENT TO BE RETAINED AND REUSED WILL BE SURVEYED AND

VALIDATED TO ESTABLISH CONDITION AND CAPACITIES. ANY

EXISTING DAMAGE TO EQUIPMENT IS TO BE RECORDED AT THIS

STAGE BY THE CONTRACTOR AND A FULL WRITTEN REPORT

SUBMITTED TO THE FACILITY REPRESENTATIVE FOR REVIEW. THE

REPORT WILL INCLUDE PHOTOGRAPHIC EVIDENCE OF DAMAGE.

7. CONTRACTOR TO CROSS REFERENCE DEMOLITION & NEW

CONSTRUCTION DRAWINGS TO ENSURE CONSISTENCY IN DESIGN

INTENT BEFORE PROCEEDING WITH ANY DEMOLITION WORK. ANY

PIPE, VALVE, EQUIPMENT THAT IS MISTAKENLY DEMOLISHED SHALL

BE RESTORED AT CONTRACTOR'S COST.

8. ALL POWER SUPPLIES TO EXISTING EQUIPMENT TO BE REMOVED

SHALL BE ISOLATED AND MADE SAFE PER NEC PRIOR TO

DEMOLITION STARTS. THIS PROCESS SHALL BE COORDINATED WITH

FACILITY REPRESENTATIVES.

9. CONTRACTOR TO DO PRE-DEMOLITION SURVEY AND RED TAG

UTILITIES FOR DEMOLITION. COORDINATE WITH FACILITY

REPRESENTATIVE ALL PROPOSED UTILITY SHUT DOWN AND

ISOLATION PRIOR TO DEMOLITION.

1. SYSTEMS TO BE BALANCED TO AIR QUANTITIES SHOWN ON PLANS

AND AS BUILT DRAWINGS. PROVIDE AN INDEPENDENT AIR BALANCE

REPORT CERTIFIED BY AABC.

2. DUCT INSULATION SHALL BE APPROVED AND MEET CLASS 1

REQUIREMENTS NOT TO EXCEED A FLAME SPREAD OF 25 NOR

SMOKE DEVELOPED RATING OF 50.

3. ALL REQUIRED CEILING/WALL ACCESS PANELS ARE FURNISHED

UNDER THE MECHANICAL SECTION AND INSTALLED BY THE

GENERAL CONTRACTOR. SUBMIT SHOP DRAWINGS FOR REVIEW

PRIOR TO INSTALLATION.

4. UPON COMPLETION OF THE TEST AND BALANCE OF THE HVAC

SYSTEMS AND WITH THE SYSTEM OPERATING AT DESIGN CAPACITY,

AIR-BORNE SOUND LEVEL MEASUREMENTS SHALL BE MADE TO

FIELD VERIFY NOISE EMISSIONS IN ACCORDANCE WITH

SPECIFICATIONS AND LOCAL ORDINANCES.

5. DURING CONSTRUCTION, PROTECT OPENINGS AND MECHANICAL

EQUIPMENT FROM DUST AND POLLUTANTS; SEAL PERMANENT HVAC

DUCTS/EQUIPMENT STORED ON SITE.

CONSTRUCTION NOTES

DEMO NOTESGENERAL NOTES

M0.0 MECHANICAL GENERAL NOTES & LEGENDS

M1.0 MECHANICAL BASEMENT DEMOLITION PLAN

M1.1 MECHANICAL FIRST FLOOR DEMOLITION PLAN

M1.2 MECHANICAL ROOF DEMOLITION PLAN

M2.0 MECHANICAL BASEMENT FLOOR PLAN

M2.1 MECHANICAL FIRST FLOOR PLAN

M2.2 MECHANICAL ROOF PLAN

M5.0 MECHANICAL DETAILS

M5.1 MECHANICAL DETAILS

M6.0 MECHANICAL SCHEDULES

M7.0 MECHANICAL CONTROLS

M7.1 MECHANICAL CONTROLS

MECHANICAL SHEETS LIST

MECHANICAL SCOPE OF WORK

· REPLACE ROOFTOP UNITS AC-2, AC-3, AND AC-4

· REPLACE FANS, EF-1 AND RF-2

· REPLACE SPLIT SYSTEMS FC/CU-4, 5 AND 6

· REPLACE DUCTWORK AND DIFFUSERS SERVING THE

OFFICE AND BASEMENT SPACES

· RECONFIGURE LOBBY SUPPLY AND RETURN DUCTWORK

DISTRIBUTION

· PROVIDE SUPPLY AIR TO RESTROOMS FROM AC-2

· ADD FC/CU-7 TO SERVE STORAGE ROOM

AC AIR CONDITIONING UNIT

ADJ ADJUSTABLE

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AP ACCESS PANEL

APD AIR PRESSURE DROP

AVG AVERAGE

BDD BACKDRAFT DAMPER

BHP BRAKE HORSEPOWER

BMS BUILDING MANAGEMENT SYSTEM

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

C/W COMPLETE WITH

CFM CUBIC FEET PER MINUTE

DB DRY BULB TEMPERATURE

dB DECIBEL(S)

DDC DIRECT DIGITAL CONTROL

DEG DEGREE

DIA./Ø DIAMETER

DIFF DIFFERENTIAL

DIV DIVISION

DN DOWN

DWG DRAWING

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EER ENERGY EFFICIENCY RATIO

ER EXISTING RELOCATED (NEW

CONSTRUCTION PLANS)

ESP EXTERNAL STATIC PRESSURE

EWT ENTERING WATER TEMPERATURE

EXIST/E EXISTING (DEMOLITION AND NEW

CONSTRUCTION PLANS)

FLA FULL LOAD AMPERAGE

FP FIRE PROTECTION

FPM FEET PER MINUTE

FPS FEET PER SECOND

FT FOOT/FEET

GA GAUGE

GAL GALLON

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

HEPA HIGH EFFICIENCY PARTICULATE

AIR (FILTER)

HP HORSEPOWER

HR HOUR

HVAC HEATING / VENTILATION / AIR

CONDITIONING

HZ HERTZ

IE INVERT ELEVATION

IN INCHES

IN WG INCHES WATER GAUGE

IPLV INTEGRATED PART LOAD FAILURE

kW KILOWATT kW KILOWATT HOUR

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LF LINEAR FEET

LWT LEAVING WATER TEMPERATURE

M METER

MAX MAXIMUM

MBH THOUSAND OF BTUH

MCA MINIMUM CIRCUIT AMPS

MFR MANUFACTURER

MIN MINIMUM

MOP MAXIMUM OVERCURRENT

PROTECTION

MVD MANUAL VOLUME DAMPER

N/A NOT APPLICABLE

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NPS NOMINAL PIPE SIZE

NTS NOT TO SCALE

OA OUTSIDE AIR

OFCI OWNER FURNISHED, CONTRACTOR

INSTALLED

PG PROPYLENE GLYCOL

POE POINT OF ENTRANCE

POS POINT OF SERVICE

PPM PARTS PER MILLION

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH,

ABSOLUTE

PSIG POUNDS PER SQUARE INCH, GAGE

RA RETURN AIR

RELA RELIEF AIR

REQD REQUIRED

RH RELATIVE HUMIDITY

RPM REVOLUTIONS PER MINUTE

ABBREVIATIONS ABBREVIATIONS

SA SUPPLY AIR

SP STATIC PRESSURE

TA TRANSFER AIR

TEMP TEMPERATURE

TSP TOTAL STATIC PRESSURE

TSTAT THERMOSTAT

TYP TYPICAL

UG UNDERGROUND

UP UP

VAV VARIABLE AIR VOLUME

VFD VARIABLE FREQUENCY DRIVE

VIF VERIFY IN FIELD

VTR VENT-THRU-ROOF

W/ WITH

W/O WITHOUT

WB WET BULB TEMPERATURE

WG WATER GAUGE

X EXISTING TO BE DEMOLISHED

°C CELSIUS

°F FAHRENHEIT

AC-# AIR COMPRESSOR

ACU-# AIR CONDITIONING UNIT

AHU-# AIR HANDLING UNIT

CU-# CONDENSING UNIT

E-# EXHAUST GRILLE / REGISTER /

DIFFUSER

EF-# FAN EXHAUST

RF-# FAN RETURN

F-# FAN

FC-# FAN COIL UNIT

R-# RETURN AIR GRILLE / REGISTER /

DIFFUSER

S-# SUPPLY GRILLE / REGISTER /

DIFFUSER

EH-# ELECTRIC HEATER

EQUIPMENT IDENTIFICATION

OUTDOOR DESIGN CONDITIONS

LOCATION: BOULDER CITY, NEVADA

ELEVATION: 2458 FT

SUMMER DESIGN: 115 DEG F DB / 73 DEG F WB

WINTER DESIGN: 27 DEG F

APPLICABLE CODES

THE CONTRACTOR SHALL COMPLY WITH ALL

APPLICABLE LAWS AND CODES AND INCLUDE, BUT NOT

BE LIMITED TO, THE LATEST ADOPTED EDITIONS OF:

2018 INTERNATIONAL BUILDING CODE

2018 INTERNATIONAL EXISTING BUILDING CODE

2018 UNIFORM MECHANICAL CODE

2018 UNIFORM PLUMBING CODE

2017 NATIONAL ELECTRICAL CODE

2018 INTERNATIONAL ENERGY CONSERVATION CODE

SOUTHERN NEVADA AMENDMENTS

ASHRAE STANDARDS

WHERE LAWS AND CODES ARE FOUND TO BE IN

CONFLICT WITH EACH OTHER,THE MORE STRINGENT

REQUIREMENTS WILL PREVAIL.

MATCH LINE

DRAWING REVISION

NORTH ARROW

LEVEL CALLOUT

WALL SECTION CALLOUT

BUILDING SECTION CALLOUT

INTERIOR ELEVATION CALLOUT

EXTERIOR ELEVATION CALLOUT

DETAIL CALLOUT

SHEET NUMBER

DETAIL NUMBER

GENERAL SYMBOLS

POINT OF CONNECTION (POC)

POINT OF DISCONNECT (POD)

DAT

06/30/2024

04/26/2023

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

WOOD NAILER

B

ROOF DECKING

ROOF INSULATION

ROOFING MATERIAL

ABS PLASTIC

CURB COVER

MULTIPLE PIPE

PORTAL

ROOF

ROOF RAIL

ROOF RAIL CAP

VIBRATION ISOLATION AND RAIL

MOUNTING PER SPECIFICATIONS

STAINLESS STEEL DISCHARGE DUCT. PROVIDE

BACK DRAFT DAMPER AND FRAMED BIRD SCREEN

OVER OPENING.

FLEX

DRAIN

WOOD NAILER

BLOCKING

NOTE: ALL DUCTWORK ABOVE ROOF TO BE STAINLESS

REFER TO ARCH DRAWINGS

FOR ROOFING DETAILS

EQUIPMENT MOUNTING

POINT

EQUIPMENT

CAP FLASHING

WOOD NAILER

EQUIPMENT ROOF

CURB / RAIL

ROOFING MATERIAL

ROOF DECKING / SLAB

NOTES:

1. COORDINATE THE LOCATION AND SIZE OF THE EQUIPMENT RAIL BASED

ON THE EQUIPMENT

2. THE PURPOSE OF THE EQUIPMENT RAIL IS TO SUPPORT THE WEIGHT

OF THE EQUIPMENT. IT SHALL BE RATED FOR THE OPERATING WEIGHT

OF THE EQUIPMENT. FOLLOW VIBRATION / SEISMIC REQUIREMENTS

PER THE CONTRACT DOCUMENTS.

3. THE RAIL IS TO BE MOUNTED A MINIMUM OF 18 INCHES / 46 CM ABOVE

THE TOP OF THE ROOF UNLESS NOTED OTHERWISE.

1" SPACE - PACK WITH FIBROUS PACKING

16 GAUGE TELESCOPING SHEET METAL SLEEVE

SET IN WALL

DUCT JOINTS

SEAL ALL AROUND

1" SPACE - PACK WITH FIBROUS PACKING

SEAL ALL AROUND

DUCT JOINTS

16 GAUGE TELESCOPING SHEET

METAL SLEEVE SET IN WALL

WOOD BLOCKING

ROOF DECKING

ROOF INSULATION

SECURE CAP TO CURB

COUNTERFLASHING INTEGRAL

TO DUCT

STAINLESS STEEL

CONSTRUCTION ABOVE ROOF

GASKET OR SEALANT

ROOF CURB

ROOFING MATERIAL

DUCT ROOF DECKING

ROOFING MATERIAL

WOOD BLOCKING

PIPING

ROOF INSULATION

SUPPORT TO FASTEN TO CURB

NAILER ON VERTICAL SIDE

SEE SPECIFICATION FOR

SPACING OF SUPPORTS

ROLLER

RAIL

SEAL ALL AROUND

SECURE SAFING TO PARTITION

PACK GLASS FIBER INSULATION AROUND DUCT

FULL DEPTH OF PARTITION

STUD PARTITION

SEAL ALL AROUND

SHEETMETAL SAFING ALL AROUND

DUCT

WOOD BLOCKING

ROOF DECKING

ROOF INSULATION

SUPPORT TO FASTEN TO CURB

NAILER ON VERTICAL SIDE

RAIL

ROOFING MATERIAL

SEE SPECIFICATION FOR

SPACING OF SUPPORTS

DUCT

DUCT MOUNTING PEDESTAL

AS SPECIFIED

STAINLESS STEEL DRAWBANDS

EDPM RUBBER CAP

CURB

WOOD BLOCKING

MITER (TYP)

HSS 4X4X1/4

HS

S

4X 4X

1/4

(TYP)

HSS 4X4X1/4

HS

S

4X 4X

1/4

(TYP)

4'-2" MAX.

4'-2"

3'-0"

7'-2" MAX.

1/4" STIFFENER PLATES

@ BEAM SIDES

BEAM

3/16

1/4

MAX. SPACING= 10'-0" O.C.

SEE DETAIL A

FINISHED ROOF

HSS COLUMN

3" SQUARE TUBE (TYP)

DETAIL A

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

RECTANGULAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT

ROUND

DUCT

ROUND DUCT

AIR FLOW AIR FLOW AIR FLOW

CONICAL TEE

FITTING WITH FLANGE

TYPICAL TAKEOFF FROM RECTANGULAR

TO ROUND DUCT - SHOE TAP

TYPICAL TAKEOFF FROM RECTANGULAR

TO ROUND DUCT - BELL MOUTH

TYPICAL TAKEOFF FROM RECTANGULAR

TO ROUND DUCT - SHOE TAP

NOTES:

1. HOLE IN RECTANGULAR DUCT SHALL BE CUT LARGE ENOUGH SO THAT ROUGH METAL EDGE SHALL NOT PROJECT INTO

AIR STREAM.

2" R

45°

45°

1-1/2"

1-1/2"

TURNING VANES

(SEE DETAIL THIS SHEET)

RECTANGULAR

DUCT ROUND DUCT

SLOPE NOT TO EXCEED 1" IN 3"SLOPE NOT TO EXCEED 1" IN 3"

DETAIL OF TURNING VANES

TYPICAL RECTANGULAR TO ROUND TRANSITIONTYPICAL RECTANGULAR TRANSITIONFULL RADIUS 45° ELBOWCONSTRUCTION OF 90° ELBOW

USE THIS DESIGN

WHERE 45° ROUND OR

RECTANGULAR RADIUS

ELS ARE SHOWN ON

PLANS

USE THIS DESIGN

WHERE SQUARE 90° ELS

ARE SHOWN ON PLANS

OR IF SPACE

CONDITIONS DO NOT

PERMIT INSTALLATION

OF RADIUS 90° ELS

SQUARE 90° ELBOWFULL RADIUS 90° ELBOW

USE THIS DESIGN

WHERE 90° ROUND

OR RECTANGULAR

RADIUS ELS ARE

SHOWN ON PLANS

1 1/2 W

1 1/2 WW W

W

WW

W

CL

CL

CL

CL

TRANSITION AS REQ'D.

(TYPICAL)

MAIN

TRANSITION AS REQ'D.

(TYPICAL)

EQUAL SIDE

(TYPICAL)

DUCT SPLIT RATIO

(SIZE FOR EQUAL

VELOCITIES)

OPPOSED ACTING BLADESCONNECTING LINKAGE

HINGE POINTOPERATING SHAFT

FOR QUADRANT LOCK

VANES

(TYPICAL)

TURN VANES

DUCT SPLIT RATIO

(SIZE FOR EQUAL

VELOCITIES)

R=W MIN. AIR

FLOW

TYPICAL VOLUME DAMPERSQUARE DIVERGING MAINSQUARE BRANCH TAKEOFFSPLIT MAIN

DISCHARGE AT NEAREST EQUIPMENT

DRAIN. REFER TO PLANS FOR

LOCATIONS. ROUTE THE PIPING SO

AS NOT TO OBSTRUCT WALKING

PATHWAYS. PROVIDE THE CODE

REQUIRED AIR GAP WHERE THE

PIPING TERMINATES AT THE

EQUIPMENT DRAIN.

CLEANOUT PLUG

DRAIN PAN

SLOPE PIPE AT 2%

H1 H2

H 1 : BLOW-THRU = 1 INCH (25MM)

H 1 : DRAW-THRU = FAN INLET PRESSURE (IN WC) + 1 INCH OR FAN INLET PRESSURE IN MM + 25MM H 2 : BLOW-THRU = FAN OUTLET PRESSURE (IN WC) + 1 INCH OR FAN OUTLET PRESSURE IN MM + 25MM H 2 : DRAW-THRU = 1/2 OF THE FAN INLET PRESSURE (IN WC) + 1/2 INCH OR 1/2 OF THE FAN INLET PRESSURE IN MM + 13MM

NOTES:

1. INCREASE UNIT PAD / STRUCTURE / CURB HEIGHT FOR FLOOR MOUNTED EQUIPMENT TO ACHIEVE THE HEIGHT

REQUIRED TO INSTALL THE TRAP DEPTH. THE PRESSURES SHALL BE BASED ON 1.25 TIMES THE SCHEDULED AHU

STATIC PRESSURE

2. IF THE TRAP IS LOCATED OUTDOOR OR IN AN UN-HEATED SPACE, PROVIDE A DRAIN W/ BALL VALVE IN THE LOW POINT

OF THE TRAP WITH A CAP. THIS WILL ALLOW THE TAP TO BE DRAINED IF REQUIRED.

3. REFER TO THE CONTRACT DOCUMENTS FOR PIPE MATERIAL AND INSULATION REQUIREMENTS.

4. THE TRAP PIPE SIZE SHALL BE A MINIMUM OF 1-1/2" / 40MM. REFER TO THE CHART ABOVE FOR THE CONDENSATE DRAIN

SIZE (UNLESS NOTED ELSEWHERE IN THE CONTRACT DOCUMENTS THAT THE PIPE SIZE SHOULD BE LARGER THAN NOTED IN THE CHART). THE DRAIN LINE SHALL NEVER BE SMALLER THAN THE DRAIN PAN CONNECTION.

DUCT SIZE AS SHOWN ON

DRAWING

VERTICAL DUCT EQUAL TO THE

GRILLE NECK SIZE (AS NOTED ON

THE GRILLE SCHEDULE) OWN AND

CONNECT DIRECTLY TO THE

GRILLE.

GRILLE FACE SIZE SHALL BE AS

NOTED IN THE CONTRACT

DOCUMENTS

SHOE TAP

NOTES:

1. APPLIES TO ALL DUCTED RETURN AND EXHAUST GRILLES EXCEPT FOR WHEN THE CONTRACTOR ELECTS TO USE

ANOTHER APPROVED DETAIL

WOOD NAILER VIBRATION ISOLATION

AND FAN BASE

ROOFING MATERIAL

REFER TO ARCH DRAWINGS

FOR ROOFING DETAILS

EQUIPMENT ROOF CURB/RAIL

CAP FLASHING

EQUIPMENT MOUNTING

POINT

FAN DISCHARGE

ATTACHMENT POINTS TO

STRUCTURAL SUPPORT

STEEL (TYP)

STACK

FLEX

STRAIGHT LENGTH

OF DUCTWORK AT

FAN INLET SIZE

DUCT SIZE

MOTORIZED

DAMPER

DRAIN

TRAP

FAN

'0"

/30 5C

M

MI

NI

MU

M

NOTES:

1. COORDINATE THE LOCATION AND SIZE OF THE EQUIPMENT RAIL

BASED ON THE EQUIPMENT

2. THE PURPOSE OF THE EQUIPMENT RAIL IS TO SUPPORT THE

WEIGHT OF THE EQUIPMENT. IT SHALL BE RATED FOR THE

OPERATING WEIGHT OF THE EQUIPMENT. FOLLOW VIBRATION /

SEISMIC REQUIREMENTS PER THE CONTRACT DOCUMENTS.

3. THE TOP OF THE RAIL/CURB IS TO BE MOUNTED A MINIMUM OF 18

INCHES / 46 CM ABOVE THE TOP OF THE ROOF UNLESS NOTED

OTHERWISE.

4. REFER TO THE CONTRACT DOCUMENTS FOR DUCT MATERIAL AND

INSULATION REQUIREMENTS.

5. THE STRAIGHT DUCT BEFORE THE FAN INLET SHALL BE A MINIMUM

OF 3 DUCT DIAMETERS.

6. FILL THE TRAP PRIOR TO START-UP. FOLLOW THE MFRS

REQUIREMENTS FOR DEPTH OF TRAP BASED ON THE FAN STATIC

PRESSURE. PROVIDE A CAP FOR THE TRAP IN A PLASTIC BAG THAT

IS FASTENED TO THE TRAP.

7. SET STACK FLANGE AND VIBRATION ISOLATION BASES IN SILICONE

CAULKING.

8. ENCAPSULATE ALL STACK AND FAN FASTENERS IN SILICONE

CALKING.

9. FLANGES AND GUSSETS ARE WELDED TO THE STACK.

10. EXIT CONE OUTLET SHALL BE CONSTRUCTED TO ACHIEVE A

MINIMUM EXIT VELOCITY OF 3000 FPM.

11. COORDINATE SCOPE OF WORK WITH ROOFING CONTRACTOR /

OWNER TO NOT VOID ANY WARRANTIES.

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

ROOF TOP UNIT SCHEDULE - PART A

UNIT IDENTIFICATION AIRFLOW PHYSICAL CHARACTERISTICS COMPONENTS

MARK NUMBER LOCATION AREA SERVED

SUPPLY AIR

(CFM)

MIN

OUTSIDE

AIR

(CFM)

UNIT

OPERATING

WEIGHT

(LBS)

MAXIMUM UNIT DIMENSIONS FILTER HEATING SECTION DX COOLING COIL

HEIGHT

(IN)

WIDTH

(IN)

LENGTH

(IN) FILTER TYPE MERV

RATING

MAX APD

(IN-WG)

HEATING

AIRFLOW

(CFM)

EAT

(F)

LAT

(F)

OUTPUT

RATING

(MBH)

TOTAL

CAPACITY

(MBH)

SENSIBLE

CAPACITY

(MBH)

EDB

(F)

EWB

(F)

LDB

(F)

LWB

(F)

MAX APD

(IN-WG)

AC 2 EAST ROOF RESTROOM, OFFICE, BASEMENT 4,450 1,400 1,435 58 64 116 2 13 0.14 4,450 56 75.8 87.9 117.0 117.0 87.6 65.5 61.2 56.8 - AC 3 SOUTH ROOF AUDITORIUM 3,850 750 1,375 49 60 89 2 13 0.21 3,850 61 81.9 80.4 99.3 94.5 82.8 64.2 58.2 55.4 - AC 4 LOW ROOF LOBBY 1,600 250 850 34 47 75 2 13 0.17 1,600 61 83 38.1 38.1 34.9 80.0 67.0 57.9 54.9 -

ROOF TOP UNIT SCHEDULE - PART B

UNIT IDENTIFICATION CONDENSER SECTION FANS CAPACITY AND PERFORMANCE ELECTRICAL

MANUFACTURER MODEL

NUMBER NOTES

MARK NUMBER

COMPRESSORS EVAP FAN COND. FANS SUPPLY (2 SPEED 66% AND 100%)

NOMINAL

CAPACITY

(TONS)

EER IEER REFRIG

TYPE

REFRIG

CHARGE VOLTS PHASE MCA MOCP

NOTE 3

CONV

OUTLET

115 V/20a

NOTE 5

FUSED

DISCONNECTNO. OF

COMP.

NO. OF

STAGES

NO. OF

CIRCUIT

TYPE OF

COMP.

NO. OF FANS

ECM

NO. OF FANS

ECM

ESP

(IN-WG) BHP HP

SPEED

(RPM)

AC 2 2 2 1 VANE AXIAL 1 3 1.8 2.9 5 1,819 12.5 10.6 15.0 410 24 LBS 14 OZ 460 3 24.0 30 YES YES CARRIER 50FCQM14A ALL

AC 3 2 2 1 VANE AXIAL 1 1 1.3 2.3 3 1,913 10.0 11.0 15.0 410 21 LBS 5 OZ 460 3 28.0 30 YES YES CARRIER 50FCQM12A ALL

AC 4 1 1 1 VANE AXIAL 1 1 1.3 1.0 1.5 2,141 4.0 14.3 ARI SEER N/A 410 11 LB 13 OZ 460 3 11.0 15 YES YES CARRIER 50FCQA05A ALL

NOTES:

1. FILTERS ARE TO BE PROVIDED WITH PRE-FILTER. MAXIMUM PRESSURE DROP SHALL BE BASED ON TOTAL PRESSURE DROP ACROSS THE FILTER BANK WITH DIRTY FILTERS. EXTERNAL STATIC ALSO INCLUDES DUCT MOUNTED ELECTRIC HEATING COILS

2. PROVIDE UNIT WITH 14" CURB. REFER TO MECHANICAL DETAILS FOR CURB FILLING MATERIAL REQUIREMENTS.

3. PROVIDE WITH POWERED EXHAUST FANS WHICH REQUIRE FIELD SUPPLIED DISCONNECTS BY DIV. 26

4. PROVIDE UNIT WITH ECONOMIZER

5. FUSED DISCONNECT BY DIV 26

6. SUMMER OUTDOOR TEMP IS 115 AND WINTER IS 27 DEGREES F. PROVIDE WITH LOW AMBIENT KIT WITH HEAD PRESSURE CONTROL. UNIT SELECTED AT ELEVATION 2200

7. PROVIE WITH MANUFACTURER'S STANDALONE CONTROLS

GRILLE, REGISTER, DIFFUSER SCHEDULE

UNIT IDENTIFICATION DIFFUSER

FACE SIZE

(IN)

DIFFUSER

NECK SIZE

(IN)

MOUNTING

TYPE COLOR MATERIAL ACCESSORY MANUFACTURER MODEL NUMBER NOTES

MARK NUMBER

SG 1 SEE PLANS SEE PLANS WALL/DUCT NOTE 3 STEEL - TITUS 272FL ALL

SG 2 36x4 SEE PLANS FLOOR NOTE 3 STEEL AG-35 OBD TITUS CT--580 1,3

RG 1 24X24 SEE PLANS CEILING NOTE 3 STEEL - TITUS PAR ALL

RG 2 SEE PLANS SEE PLANS WALL/DUCT NOTE 3 STEEL - TITUS 272FL ALL

EG 1 SEE PLANS SEE PLANS CEILING NOTE 3 STEEL - TITUS 3FL ALL

NOTES:

1. REFER TO REFLECTED CEILING PLANS EXACT LOCATION. PROVIDE ALL FRAMES AND ACCESSORIES AS REQUIRED FOR PROPER INSTALLATION.

2. FLEXIBLE DUCTWORK SHALL BE THE SAME SIZE AS THE DIFFUSER NECK OR AN EQUIVALENT ROUND DUCT. FLEXIBLE DUCTWORK SHALL BE SUPPORTED TO PREVENT KINKS OR BENDS.

3. COLORS TO BE SELECTED TO MATCH EXISITNG BUILDING FINISHES.

4. PROVIDE OPPOSED BLADE DAMPERS FOR ALL GRILLES ON PLANS, UNLESS SHOWN WITH VOLUME DAMPER.

SPLIT SYSTEM AIR CONDITIONING UNIT SCHEDULE

UNIT IDENTIFICATION INDOOR UNIT

MANUFACTU

RER NOTES

MARK NUMBER ROOM(S) SERVED

COOLING

CAPACITY

(BTU/H)

HEATING

CAPACITY

(BTU/H)

AIRFLOW

(CFM)

FILTER

RATING

(MERV)

MOUNTING

CONDENSA

TE PUMP

REQUIRED

OPERATING

WEIGHT

(LBS.)

MODEL

NUMBER TAG

AMBIENT

DESIGN

TEMP (F)

ELECTRICAL OPERATING

WEIGHT

(LBS.)

MODEL

NUMBERVOLTS PHASE MOP

FC 4 ELEV. MACHINE ROOM 18.0 21.0 450 WASHABLE WALL YES - INTEGRAL 28 MSZ-GL18NA CU-4 115.0 208 1 14 15 121 MUZ-GL18NA MITSUBISHI ALL

FC 5 ELECTRICAL ROOM 18.0 21.0 450 WASHABLE WALL YES - INTEGRAL 28 MSZ-GL18NA CU-5 115.0 208 1 14 15 121 MUZ-GL18NA MITSUBISHI ALL

FC 6 PROJECTOR ROOM 18.0 21.0 450 WASHABLE WALL YES - INTEGRAL 28 MSZ-GL18NA CU-6 115.0 208 1 14 15 121 MUZ-GL18NA MITSUBISHI ALL

FC 7 STORAGE ROOM 18.0 21.0 450 WASHABLE WALL YES - INTEGRAL 28 MSZ-GL18NA CU-7 115.0 208 1 14 15 121 MUZ-GL18NA MITSUBISHI ALL

NOTES:

1. OUTDOOR UNIT POWERS INDOOR UNIT. PROVIDE ALL INTERCONNECTING WIRING BETWEEN THE INDOOR AND OUTDOOR UNITS. OUTDOOR UNIT POWERS CONDENSATE PUMP WITH SHUTOFF CAPIBLIITY. SINGLE POINT POWER FOR OUTDOOR, INDOOR, & CONDENSATE PUMP.

2. PROVIDE PIPE PORTAL AT ALL ROOF PENETRATIONS.

3. OUTDOOR UNIT TO BE MOUNTED ON ROOF CURB RAILS.

4. SPEED BASED ON [HIGH] SPEED. PROVIDE WIRED TEMPERATURE CONTROL

5. DISCONNECT BY DIV 26

6. CONDENSATE PUMP MAXIBLUE ADVANCED BLUE DIAMOND MINI CONDENSATE PUMP WITH RESERVOIR AND SENSOR. MODEL 110v - X87-771. CONNECT TO EXISTING CONDENSATE PIPING; CLEAN EXISTING DRAIN PIPE PRIOR TO INSTALLATION OF NEW PUMP.

7. SYSTEM SIZED FOR 2200 FT ELEVATION

ELECTRIC DUCT HEATER SCHEDULE

UNIT IDENTIFICATION ELEMENT ELECTRICAL

MANUFACTURER NOTES

MARK NUMBER SYSTEM ROOM(S) SERVED KW NO OF

STAGES VOLTS PHASE

(E) EH 2 AC-3 AUDITORIUM 30.0 4 480 3 INDEECO 1

(E) EH 3 AC-2 OFFICE/BASEMENT/RESTROOMS 20.0 4 480 3 INDEECO 1

(X) EH 4 AC-3 STORAGE 5.0 4 480 3 INDEECO 1,2

(N) EH 5 AC-2 RESTROOMS 12.0 1 480 3 INDEECO 1,3

NOTES:

1. ELECTRIC DUCT HEATERS SHOWN FOR REFERENCE ONLY. SCHEDULED INFORMATION IS TAKEN FROM AS-BUILTS.

2. ELECTRIC DUCT HEATER SHALL BE DEMOLISHED.

3. NEW ELECTRIC DUCT HEATER INSTALLED IN DUCTWORK. SEE DRAWINGS.

FAN SCHEDULE

UNIT IDENTIFICATION MAX

AIRFLOW

(CFM)

ESP

(IN-WG)

FAN WHEEL FAN MOTOR ELECTRICAL OPERATING

WEIGHT

(LBS.)

MANUFACTURER MODEL NUMBER NOTES

MARK NUMBER UNIT/AREA SERVED TYPE

SPEED

(RPM) BHP HP DRIVE TYPE VOLTS PHASE

EF 1 RESTROOMS 820 0.8 BLOWER 1,628 0.3 1/2 BELT 115 1 155 GREENHECK USF-10-B2 1,2,3,4

RF 2 AC-2 RETURN 4,050 1.0 INLINE 1,750 1.6 2 DIRECT 460 3 175 GREENHECK SQ-16-M2 1,2

PE 2 AC-2 POWERED EXHAUST 4,450 0.5 - - - 2 - 460 3 313 MICROMETL PECE-SRT05CB-D0DB-4L2-4 4

PE 3 AC-3 POWERED EXHAUST 4,450 0.5 - - - 2 - 460 3 313 MICROMETL PECE-SRT05CB-D0DB-4L2-4 4

PE 4 AC-4 POWERED EXHAUST 1,850 0.5 - - - 1/2 - 460 3 225 MICROMETL PECH-SRT12CB-D0DB-4LH-4 4

NOTES:

1. PROVIDE UNIT WITH BACKDRAFT DAMPER

2. PROVIDE UNIT WITH VFD WITH INTEGRAL DISCONNECT.

3. UPBLAST DISCHARGE POSITION

4. PROVIDE WITH MANUFACTURER'S CURB.

5. POWERED EXHAUST REQUIRES SEPARATE FIELD SUPPLIED DISCONNECTS BY DIV. 26.

DAT

WITH WIRELESS THERMOSTAT

ON ROOF CURB RAILS.

PROVIDE WIRED TEMPERATURE CONTROLWITH WIRELESS THERMOSTAT.

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

SEQUENCE OF OPERATION:

APPLICABLE FOR AC-2, 3, AND 4

UNIT TO BE PROVIDED WITH MANUFACTURER'S STANDALONE CONTROL AND SHALL BE ABLE TO, AT A MINIIMUM, PERFORM THE FOLLOWING:

OCCUPIED/UNOCCUPIED DESIGNATION:

THE EQUIPMENT FACTORY CONTROLLER SHALL INITIATE OCCUPIED AND UNOCCUPIED MODES PER SCHEDULES FURNISHED BY THE OWNER.

WARM-UP/PRE-COOL MODE:

EQUIPMENT FACTORY CONTROLS SHALL PERFORM WARM-UP/PRE-COOL SEQUENCE BASED ON PROGRAMMED BUILDING OCCUPIED/UNOCCUPIED SCHEDULE. IF OCCUPIED SETPOINT IS MET PRIOR TO THE SCHEDULED OCCUPIED CHANGEOVER TIME BY MORE THAN THE OCCUPIED ENGAGEMENT ALLOWANCE SETPOINT, THE WARM-UP/PRE-COOL RUN-TIME SETPOINT SHALL BE ADJUSTED 5 MINUTES LATER. IF OCCUPIED SETPOINT IS NOT MET BY THE OCCUPIED MODE START TIME, THE WARM-UP/PRE-COOL RUN-TIME SETPOINT SHALL BE ADJUSTED BY 5 MINUTES EARLIER.

OCCUPIED MODE - SUPPLY FAN SPEED CONTROL:

EQUIPMENT FACTORY CONTROLS SHALL MODULATE SUPPLY FANS AS REQUIRED TO MAINTAIN THE SPACE TEMEPERATURE SETPOINT.

OCCUPIED MODE - RELIEF FAN SPEED CONTROL:

WHEN ECONOMIZER COOLING IS ENABLED, EQUIPMENT FACTORY CONTROLS SHALL MODULATE RELIEF FANS IN CONJUNCTION WITH OSA DAMPER POSITION.

OCCUPIED MODE - DISCHARGE TEMPERATURE CONTROL:

EQUIPMENT FACTORY CONTROLS SHALL CONTROL ECONOMIZER FUNCTION AND MECHANICAL COOLING/HEATING TO MAINTAIN DISCHARGE TEMPERATURE SETPOINT. IF SPACE SUPPLY FAN SPEED IS AT THE TEMPERATURE RESET HIGH LIMIT FOR A PERIOD GREATER THAN THE TEMPERATURE RESET TIME DELAY, THE DISCHARGE AIR TEMPERATURE SETPOINT SHALL BE LOWERED BY THE SUPPLY AIR RESET INCREMENT SET POINT. IF SUPPLY FAN SPEED IS AT OR BELOW THE TEMPERATURE RESET LOW LIMIT FOR A PERIOD GREATER THAN THE TEMPERATURE RESET TIME DELAY, DISCHARGE AIR TEMPERATURE SETPOINT SHALL BE INCREASED BY THE SUPPLY AIR RESET INCREMENT SET POINT. ONCE TEMPERATURE IS RESET, IT SHALL NOT RESET AGAIN UNTIL THE TEMPERATURE RESET TIME DELAY HAS BEEN

ACHIEVED.

ECONOMIZER/OUTSIDE AIR CONTROL:

EQUIPMENT FACTORY CONTROLS SHALL MODULATE OUTSIDE/RETURN AIR DAMPERS BETWEEN THE SCHEDULED MINIMUM OSA POSITION AND THE MIN OSA DCV RESET POSITION TO MAINTAIN CO2 SETPOINT, AND SHALL INCREASE OUTSIDE AIR FOR ECONOMIZER COOLING VIA DRY BULB TEMPERATURE CONTROL. CONTROL SHALL BE FULLY MODULATING. UPON DETECTION OF A CO2 SENSOR FAILURE, OUTSIDE AIR DAMPER POSITION SHALL BE SET TO THE MIN OSA DCV INCREASE POSITION, OR HIGHER AS INDICATED BY ECONOMIZER CONTROLS.

UNOCCUPIED MODE:

EQUIPMENT FACTORY CONTROLS SHALL START EQUIPMENT IN FULL RECIRCULATION MODE (UNLESS ECONOMIZER COOLING IS REQUIRED), AND MAINTAIN UNOCCUPIED SPACE TEMPERATURE SETPOINT.

PROVIDE ALL POINTS AS REQUIRED FOR A COMPLETE OPERATING SYSTEM, INCLUDING AT A MINIMUM,THE FOLLOWING:

• RETURN AIR TEMPERATURE SENSOR

• DISCHARGE AIR TEMPERATURE SENSOR

• OUTSIDE AIR TEMPERATURE SENSOR

• DIRTY FILTER ON/OFF SWITCH

• SUPPLY FAN STATUS

• SUPPLY FAN ON/OFF

• LEAVING COIL TEMPERATURE

• OUTDOOR AIRFLOW MONITORING STATION

• OUTDOOR AIR DAMPER CONTROL

• RETURN AIR DAMPER CONTROL

• ECONOMIZER CONTROL

• SPACE TEMPERATURE SETPOINT

• SPACE TEMPERATURE

• RETURN AIR CO2 SENSOR

ROOF

SUPPLY AIR MAIN

AC-X

SETPOINTS

DESIGNATION MINIMUM RANGE INITIAL SETPOINT

SUPPLY AIR RESET INCREMENT 0-5° F 1.0° F

SUPPLY AIR RESET TIME DELAY 1-10 MINUTES 5 MINUTES

SUPPLY AIR TEMPERATURE 0-80°F 55°F

WARM-UP/PRE-COOL RUN-TIME 0-180 MINUTES 60 MINUTES

TEMPERATURE RESET HIGH LIMIT 0-100% 95%

TEMPERATURE RESET LOW LIMIT 0-100% 70%

TEMPERATURE RESET TIME DELAY 0-120 MINUTES 5 MINUTES

CO2 LEVEL SETPOINT 0-2000 PPM 1000 PPM

T

STANDALONE

FACTORY MOUNTED

CONTROLLER

PROVIDE THERMOSTAT

DESIGNED TO WORK WITH THE

MANUFACTURER'S CONTROL

DAT

06/30/2022

FIN

AL D

RAFT

DAT

RAFT

T

FC CU

THERMOSTAT SETPOINTS

EA EA

MOTOR

EXHAUST

FAN

HOA

CONTROLLER

STANDALONE, 7-DAY PROGRAMMABLE CONTROLLER

WITH MANUAL OVERRIDE, AND A MINIMUM OF 3

PASSCODE PROTECTED SECURITY LEVELS

OUTDOOR UNITDUCTLESS FAN COIL

SPACE TEMPERATURE

SENSOR

NOTES:

1. APPLIES TO ALL SINGLE ZONE DUCTLESS SPLIT SYSTEMS

2. EQUIPMENT OPERATION BY LOCAL CONTROLLER

INITIAL SETPOINT

75° F55-80° F

MINIMUM RANGEDESIGNATION

SPACE TEMPERATURE

DAT

06/30/2022

FIN

AL D

RAFT

DAT

GENERAL ELECTRICAL NOTESABBREVIATIONS & DESCRIPTIONS

(RE: ALL ELECTRICAL SHEETS)

1. COLOR CODE WIRES AS FOLLOWS:

CONDUCTORS 120/208V 277/480V

PHASE A BLACK BROWN

PHASE B RED ORANGE

PHASE C BLUE YELLOW

NEUTRAL WHITE WHITE

GROUND GREEN GREEN

2. ALL SWITCHES TO BE 20 AMP 120 VOLT SPECIFICATION GRADE.

3. ALL POWER JUNCTION BOXES TO BE MARKED WITH PANEL NAME AND CIRCUIT

NUMBER WITH PERMANENT BLACK INK MARKER.

4. ALL WIRE SHALL BE STRANDED TYPE THHN/THWN, WIRE SIZE SHALL BE A MINIMUM

OF #12 AWG Cu UNLESS NOTED OTHERWISE ON PLANS. FOR LENGTHS OF 100' OR MORE, WIRE SIZE SHALL BE A MINIMUM OF #10 AWG Cu UNLESS NOTED OTHERWISE

ON PLANS.

5. ALL ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE

WITH THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE, AND ALL

OTHER STATE AND LOCAL CODES. CONTRACTOR SHALL IMMEDIATELY NOTIFY NPS

COR IN WRITING IF PORTIONS OF THE DESIGN SET OR FIELD CONDITIONS DO NOT

MEET REQUIRED CODES.

6. ELECTRICAL DEVICES ARE SHOWN BOLD FOR NEW, BOLD/DASHED FOR DEMO &

RELOCATED AND MEDIUM/DASHED FOR EXISTING.

7. DIMENSIONED LENGTHS SHALL TAKE PRECEDENCE OVER SCALED LENGTHS.

8. COORDINATE WORK WITH ALL TRADES PRIOR TO INSTALLATION.

9. PROVIDE ACCURATE RED-LINED AS BUILT DRAWINGS TO THE GOVERNMENT UPON

PROJECT COMPLETION.

10. FURNISH AND INSTALL A COMPLETE ELECTRICAL SYSTEM AS DEPICTED FROM THE

PLANS AND SPECIFICATIONS. WORK IS TO BE COMPLETE AS NOTED OR IMPLIED,

NOT LIMITED TO WHAT IS SHOWN.

11. ALL DRAWINGS ARE SCHEMATIC IN NATURE AND ALL APPURTENANCES NOT

INDICATED TO MAKE A WORKING SYSTEM MUST BE INCLUDED IN THE

CONTRACTORS BID.

12. THE CONTRACTOR IS RESPONSIBLE TO IDENTIFY CONFLICTS, INCONSISTENCIES, OR

ITEMS WHERE DESIGN INTENT IS NOT CLEAR, IN WRITING TO THE NPS COR PRIOR

TO BID. BY SUBMITTING A BID ON THIS PROJECT, THE CONTRACTOR ACCEPTS THAT

ALL ITEMS ARE UNDERSTOOD AND ACCURATELY DEPICT DESIGN INTENT. NO

ADDITIONAL COST CAN BE RECOVERED (FOR DESIGN INTENT QUESTIONS/ISSUES)

BY THIS CONTRACTOR ONCE BIDS ARE ACCEPTED.

13. ALL MOUNTING HEIGHTS OF EQUIPMENT SHALL MEET ADA REQUIREMENTS UNLESS

OTHERWISE INDICATED.

14. MAINTAIN THE SAME WIRE SIZE FROM PANEL THROUGHOUT THE ENTIRE CIRCUIT

UNO.

15. COORDINATE ALL DEVICE/FIXTURE LOCATIONS AND SPECIFIC REQUIREMENTS WITH

THE GOVERNMENT PRIOR TO ROUGH-IN.

16. CONTRACTOR IS RESPONSIBLE TO REPAIR ANY DAMAGE CAUSED BY THIS

CONTRACTOR TO NEW/EXISTING BUILDING SYSTEMS AT NO ADDITIONAL COST TO

THE GOVERNMENT.

A AMPERES

AC ABOVE COUNTER; REFER

TO ARCHITECTURAL

ELEVATIONS FOR REQUIRED

HEIGHT.

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AF AMPERE FRAME

AHJ AUTHORITY HAVING

JURISDICTION

AT AMP TRIP

AWG AMERICAN WIRE GAUGE

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

CL CRITICAL LOAD

CO CONDUIT ONLY, PROVIDE

PULL-LINE

DC DIRECT CURRENT

DET DETAIL

(E) EXISTING

EF EXHAUST FAN

F FUSE

FVNR FULL VOLTAGE NON-REVERSING

G/GND GROUND

GFI GROUND FAULT INTERRUPTION

GFP GROUND FAULT PROTECTION

HH HANDHOLE

HID HIGH INTENSITY DISCHARGE

HOA HAND OFF AUTO

HP HOUSE PHONE

IC INTERRUPTING CAPACITY

IG ISOLATED GROUND

J/JB JUNCTION BOX

KW KILOWATT

KWH KILOWATT HOUR

M MAGNETIC CONTACTOR COIL

MB MAIN BREAKER

MCC MOTOR CONTROL CENTER

MLO MAIN LUGS ONLY

MS MOTOR STARTER

(N) NEW

N NEUTRAL

NC NORMALLY CLOSED

NCL NON CRITICAL LOAD

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

OL OVERLOAD

OS OCCUPANCY SENSOR

OFCI OWNER FURNISHED

CONTRACTOR INSTALLED

P PHASE

PC PHOTOCELL

PVC POLYVINYL CHLORIDE

PWTS PUBLIC WATER

TREATMENT SYSTEM

RCPT RECEPTACLE

(R) RELOCATED

RE: REFER TO

SER SERVICE ENTRANCE RATED

SPST SINGLE POLE SINGLE THROW

TC TIME CLOCK

TDR TIME DELAY RELAY

TJB TERMINAL JUNCTION BOX

TSP TWISTED SHIELDED PAIR

TTB TELEPHONE TERMINAL BOARD

TVSS TRANSIENT VOLTAGE SURGE

SUPPRESSER

TYP TYPICAL

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

V VOLT

VA VOLT AMPERE

VFD VARIABLE FREQUENCY DRIVE

WG PROVIDE PROTECTIVE WIRE

GUARD

WP WEATHER PROOF/NEMA 3R

XFMR TRANSFORMER

CIRCUIT CONCEALED IN

CEILING OR WALL.

3/4"C-2#12,1#12G UNO.

CIRCUIT CONCEALED IN

FLOOR OR UNDERGROUND.

3/4"C-2#10,1#10G UNO.

CONDUIT STUBBED OR SLEEVE,

CAPPED, AND MARKED WITH PULL CORD

BRANCH PANEL.

CIRCUIT BREAKER. SIZE

AND TYPE AS SPECIFIED.

A

JUNCTION BOX.

FLUSH MOUNTED

PANELBOARD/ENCLOSURE. SEE

E5.0 PANEL SCHEDULE FOR TYPE.

NON-FUSED DISCONNECT

SWITCH. SIZE AS INDICATED,

NEMA 1 UNO, 3 POLE UNO.

PANEL

J

MOTOR CONNECTION.

TRANSFORMER.

DUPLEX OUTLET. +18" AFF UNO.

3/4"C 2#12:C-1

1#12:GND

CONDUCTOR

QUANTITY

GROUNDING

CONDUCTOR

SIZE

RACEWAY

SIZE

CONDUCTOR SIZE

CIRCUIT NUMBER

PANEL

FOURPLEX OUTLET. +18" AFF UNO.

SMOKE DETECTOR

COMBINATION STARTER - SEE DRAWINGS

FOR SIZE AND ENCLOSURE RATINGS.

M METER AND BASE.

ELECTRICAL LEGEND

FUSED DISCONNECT SWITCH.

SIZE AS INDICATED, NEMA 1

UNO, 3 POLE UNO.

F

POWER SYSTEM DEVICE SYMBOLS

GFI OUTLET. +18" AFF UNO.

GFI OUTLET. ABOVE COUNTER

FOURPLEX GFI OUTLET. +18" AFF

UNO.

EQUIPMENT CONNECTION

CIRCUIT WIRING SYMBOLS

ONE-LINE DIAGRAM SYMBOLS

LOW VOLTAGE AND CONTROL SYMBOLS

M

SD

DUCT SMOKE DETECTORD

CONDUIT AND WIRE SIZE CALLOUT. SEE

SHEET E3.1 FOR CONDUIT/WIRE SCHEDULE.####

VFD VARIABLE FREQUENCY DRIVE.

04/28/2023

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REPLACE ALAN BIBLE VISITOR CENTER HVAC

AutoCAD SHX Text

LAKE MEAD NATIONAL RECREATION AREA

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

M. SMITH

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

APR 2023

AutoCAD SHX Text

AutoCAD SHX Text 25005A

AutoCAD SHX Text 228968

AutoCAD SHX Text 27/04/2023 16:49 JENNIFER CHEEK G:\CLIENTS\NPS\LAKE\228968\DRAWINGS\ELEC\E0.0 COVER SHEET.DWG

AutoCAD SHX Text

ELECTRICAL COVER SHEET

AutoCAD SHX Text E0.0

AutoCAD SHX Text

04/28/2023

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

STAIR

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

MECH.

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

(E)DDC CONTROLLER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text

(E)DISTRIBUTION PANEL 'MDB' 800A, 480/277V 3 4W3 4W

AutoCAD SHX Text

(E)PANEL 'RA' 225A 208/120V 3 4W3 4W

AutoCAD SHX Text

(E)PANEL 'R' 225A 208/120V 3 4W3 4W

AutoCAD SHX Text (E)75kVA STEP DOWN TRANSFORMER, 480:208Y/120V 3 3

AutoCAD SHX Text

(E)MAIN SWITCHBOARD 1200A, 480Y/277V 3 3

AutoCAD SHX Text

(E)PV SYSTEM DISCONNECT

AutoCAD SHX Text

(E)PV REC METER

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text

1. COORDINATE DISCONNECTION OF THE HVAC EQUIPMENT WITH THE COORDINATE DISCONNECTION OF THE HVAC EQUIPMENT WITH THE NPS COR AND THE HVAC CONTRACTOR. DISCONNECT EQUIPMENT AND MAKE SAFE FOLLOWING PROPER LOCK OUT/TAG OUT PROCEDURES. 2. RETAIN AND PROTECT EXISTING DEVICE/EQUIPMENT THROUGHOUT RETAIN AND PROTECT EXISTING DEVICE/EQUIPMENT THROUGHOUT CONSTRUCTION. 3. EXISTING DDC CONTROLLER TO BE DEMOLISHED. EXISTING DDC CONTROLLER TO BE DEMOLISHED. 4. DEMO EXISTING T-STAT LOCATION TO INCLUDE DEVICE, CABLING, DEMO EXISTING T-STAT LOCATION TO INCLUDE DEVICE, CABLING, J-BOX AND ASSOCIATED CONDUIT.

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

PLAN VIEW - ELECTRICAL BASEMENT DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REPLACE ALAN BIBLE VISITOR CENTER HVAC

AutoCAD SHX Text

LAKE MEAD NATIONAL RECREATION AREA

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

M. SMITH

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

APR 2023

AutoCAD SHX Text

AutoCAD SHX Text 25005A

AutoCAD SHX Text 228968

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 27/04/2023 16:50 JENNIFER CHEEK G:\CLIENTS\NPS\LAKE\228968\DRAWINGS\ELEC\E1.0 BSMT DEMOLITION PLAN.DWG

AutoCAD SHX Text

BASEMENT ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text E1.0

AutoCAD SHX Text

CU

EH

04/28/2023

AutoCAD SHX Text

FIXT_CODE

AutoCAD SHX Text

FU_TOTAL

AutoCAD SHX Text

FU_WASTE

AutoCAD SHX Text

FU_HOT

AutoCAD SHX Text

FU_COLD

AutoCAD SHX Text

FIXT_CODE

AutoCAD SHX Text

FU_TOTAL

AutoCAD SHX Text

FU_WASTE

AutoCAD SHX Text

FU_HOT

AutoCAD SHX Text

FU_COLD

AutoCAD SHX Text

PROJECTOR

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

ACCESS

AutoCAD SHX Text

AutoCAD SHX Text

PATIO

AutoCAD SHX Text

AutoCAD SHX Text

EXHIBIT

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

LOBBY

AutoCAD SHX Text

AutoCAD SHX Text

HALL

AutoCAD SHX Text

AutoCAD SHX Text

AUDITORIUM

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

WORK

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

ROOM

AutoCAD SHX Text

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

AutoCAD SHX Text

ARCADE

AutoCAD SHX Text

AutoCAD SHX Text

PATIO

AutoCAD SHX Text

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

AutoCAD SHX Text

MEN

AutoCAD SHX Text

AutoCAD SHX Text

JANITOR

AutoCAD SHX Text

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

LIBRARY

AutoCAD SHX Text

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

UNISEX

AutoCAD SHX Text

RESTROOM

AutoCAD SHX Text

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

PRODUCT

AutoCAD SHX Text

TRADENAME

AutoCAD SHX Text

MODELNUMBER

AutoCAD SHX Text

(E)PANEL 'RB' 225A, 120/208V 3 4W

AutoCAD SHX Text

(E)SUB-PANEL TO PANEL 'RB'

AutoCAD SHX Text M

AutoCAD SHX Text

(E)CU-4 DISCONNECT

AutoCAD SHX Text (E)

AutoCAD SHX Text T

AutoCAD SHX Text F

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text T

AutoCAD SHX Text (E)

AutoCAD SHX Text

1. COORDINATE DISCONNECTION OF THE HVAC EQUIPMENT WITH THE COORDINATE DISCONNECTION OF THE HVAC EQUIPMENT WITH THE NPS COR AND THE HVAC CONTRACTOR. DISCONNECT EQUIPMENT AND MAKE SAFE FOLLOWING PROPER LOCK OUT/TAG OUT PROCEDURES. 2. RETAIN AND PROTECT EXISTING DEVICE/EQUIPMENT THROUGHOUT RETAIN AND PROTECT EXISTING DEVICE/EQUIPMENT THROUGHOUT CONSTRUCTION. 3. DEMO EXISTING T-STAT LOCATION TO INCLUDE DEVICE, CABLING, DEMO EXISTING T-STAT LOCATION TO INCLUDE DEVICE, CABLING, J-BOX AND ASSOCIATED CONDUIT.

AutoCAD SHX Text

KEY NOTES:

AutoCAD SHX Text

PLAN VIEW - ELECTRICAL FIRST FLOOR DEMOLITION PLAN

AutoCAD SHX Text

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

AutoCAD SHX Text 16'

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

REPLACE ALAN BIBLE VISITOR CENTER HVAC

AutoCAD SHX Text

LAKE MEAD NATIONAL RECREATION AREA

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

M. SMITH

AutoCAD SHX Text

B. ANDERSON

AutoCAD SHX Text

APR 2023

AutoCAD SHX Text

AutoCAD SHX Text 25005A

AutoCAD SHX Text 228968

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text 27/04/2023 16:50 JENNIFER CHEEK G:\CLIENTS\NPS\LAKE\228968\DRAWINGS\ELEC\E1.1 FIRST FLOOR DEMO PLAN.DWG

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL DEMOLITION PLAN

AutoCAD SHX Text E1.1

AutoCAD SHX Text

AC

AC 5

CU

RF

EF

AC

CU

AC

04/28/2023

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text J

AutoCAD SHX Text

(E)AC-3 DISCONNECT

AutoCAD SHX Text

(E)EH-2 DISCONNECT

AutoCAD SHX Text

(E)EH-4 DISCONNECT

AutoCAD SHX Text J

AutoCAD SHX Text

(E)CU-6 DISCONNECT

AutoCAD SHX Text

(E)RTU-1 DISCONNECT

AutoCAD SHX Text M

AutoCAD SHX Text

(E)RTU-4 DISCONNECT

AutoCAD SHX Text

(E)RTU-2 DISCONNECT

AutoCAD SHX Text

(E) EH-1 DISCONNECT 30A/3P TRS20R

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text (E)

AutoCAD SHX Text

(E)EH-3 DISCONNECT

AutoCAD SHX Text

(E)BOOSTER FAN (STARTER)

AutoCAD SHX Text

(E)CU-5 DISCONNECT

AutoCAD SHX Text (E)

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

GFCI

AutoCAD SHX Text

(E)EH-4

AutoCAD SHX Text

(E)EH-3

AutoCAD SHX Text J

AutoCAD SHX Text M

AutoCAD SHX Text…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .