This document contains plumbing fixture and equipment schedules, specifications, and drawings for a restroom renovation project at Lake Mead National Recreation Area. Key details include renovating two restrooms to include new water closets, urinals, lavatories, drinking fountains, floor drains, emergency showers, hot water heaters, and temperature mixing valves. Specific fixture models and manufacturers are listed along with notes on installation requirements. Dimensions for plumbing chases and minimum wall widths are provided. The related federal contract opportunity is for the renovation work described in the plumbing documents, to be performed at Lake Mead National Recreation Area for the Department of the Interior National Park Service Pacific West Region.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING FIXTURE SCHEDULE
MARK
FIXTURE
DESCRIPTION BASIS OF DESIGN
CONNECTIONS
FLOW
RATE
GPF OR
GPM
NOTES
S V TRAP CW HW TW
WC-1 WATER CLOSET
FLOOR MOUNTED, ELONGATED
BOWL, SIPHON JET,
1.28 GPF, ADA
BRIGGS CARLTON MODEL #7790, CENTOCO
NO. 1500STSCCSS OPEN FRONT SEAL LESS
COVER, FLUSH VALVE SLOAN MODEL #
111-1.28
4" 2" 4" 1" - - 1.1
WC-2 WATER CLOSET
FLOOR MOUNTED, ELONGATED
BOWL, SIPHON JET,
1.28 GPF
BRIGGS CARLTON MODEL #7714, CENTOCO
NO. 1500STSCCSS OPEN FRONT SEAL LESS
COVER, FLUSH VALVE SLOAN MODEL #
111-1.28
4" 2" 4" 1" - - 1.1
UR-1 URINAL
WALL HUNG, HIGH EFFICIENCY, 0.125
GPF, ADA
BRIGGS LAWTON # 7552, 3/4" TOP SPUD WITH
SLOAN MODEL # 186-0.125 FLUSH VALVE,
ZURN FLOOR CARRIER Z-1218
2" 1-1/2" 2" 3/4" - - 0.125
L-1 LAVATORY
WALL HUNG, ADA
BRIGGS MILTON # 6620 WITH MOEN FAUCET
MODEL # 8420
1-1/2" 1-1/2" 1-1/4" 1/2" - 1/2" 0.35 1
MS-1 JANITOR'S SINK
FLOOR MOUNTED, TERRAZZO, 12"
DEPTH
FIAT MODEL # TSB300 WITH CHICAGO
MODEL # 897-CP FAUCET
3" 1-1/2" 3" 1/2" - 1/2" - 2
(E) DF-1
DRINK FOUNTAIN
EXISTING TO BE RELOCATED
MODEL ELKAY EZH2O
- 1-1/2" 1-1/2" 1-1/4" 1/2" - - -
(E) ES-1
EMERGENCY SHOWER/EYE WASH
EXISTING TO BE RELOCATED
MODEL BRADLEY
- - - - - - 1-1/4" 23
NOTES:
PROVIDE FLOOR CARRIER WITH CONCEALED ARMS, 1/2 GPM FLOW RESTRICTOR, INSULATE TRAP AND SUPPLIERS WITH TRUEBRO NO. 103 LAV GUARD.
PROVIDE MSG STAINLESS STEEL WALL GUARDS, STAINLESS STEEL CAPS ON ALL CURBS, 832AA HOSE & HOSE BRACKET AND 889CC MOP HANGER.
PLUMBING ELECTRIC WATER HEATER SCHEDULE
MARK FUEL SERVICE
LOCATION/
SERVICE
ELECTRICAL CHARACTERISTICS WATER CHARACTERISTICS
MANUFACTURER
BASIS OF
DESIGN
SIZE (IN) &
WEIGHT (LBS)
NOTES
AMPS KW V PH HZ
TANK
VOLUME
GAL
RECOVERY
CAPACITY GPH
EWT
DEG F
LWT
DEG F
CW CONN
IN
EWH-1 ELECTRIC
DOMESTIC HOT
WATER
FIRST
FLOOR
19 4.5 240 1 60 120 16 45 160 1-1/4"
BRADFORD
WHITE
E32-120R-3
28 1/4 DIA X 64 H
312 LBS
1,2
NOTES:
1. FACTORY INSTALLED T&P RELIEF VALVE AND DRAIN VALVE. 2. TOTAL WEIGHT WITH COMPLETELY FILLED WATER IS APPROX. 1300 LBS.
PLUMBING DRAIN SCHEDULE
TYPE DESCRIPTION OUTLET MANUFACTURER MODEL NUMBER GRATE NOTES
FD-1 FLOOR DRAIN 3" ZURN Z415S-P
5"x5" POLISHED NICKEL
BRONZE TOP
NOTES:
1. SQUARE TOP WITH TRAP PRIMER CONNECTION.
PLUMBING TEMPERATURE MIXING VALVE SCHEDULE
EQUIPMENT NUMBER EQUIPMENT DESCRIPTION
LOCATION LEVEL
& / OR ROOM
MAX
FLOW
(GPM)
PRESS
DROP
(PSI)
MANUFACTURER & MODEL NUMBER NOTES
TMV-1
DOMESTIC HOT WATER -
MIXING VALVE -
RESTROOMS
MEZZANINE 4 15 ACORN ST70-38 1
TMV-2
DOMESTIC HOT WATER
-EMERGENCY SHOWER
MEZZANINE
34 15
GUARDIAN G3700LF 1
NOTES:
1. LISTED EQUIPMENT MANUFACTURERS ARE THE BASIS OF DESIGN.
MINIMUM PLUMBING CHASE WALL WIDTH REQUIREMENTS
FIXTURE TYPE
FIXTURE MOUNTING
DESCRIPTION
DIMENSION FROM OUTER EDGE OF STUD TO OUTER EDGE OF STUD (INCHES)
SINGLE DOUBLE BACK TO BACK
DRINKING FOUNTAINS
WALL HUNG DRINKING FOUNTAIN 6" 6"
WALL HUNG WATER COOLER 12"
12", OFFSET
FLOOR DRAIN IN FLOOR 6" 6"
LAVATORY WALL HUNG 6" 6"
SERVICE SINK FLOOR MOUNT 6" 6"
WATER CLOSET
FLOOR MOUNT, FLUSH VALVE
6" 6"
FLOOR MOUNT, FLUSH VALVE
6" 6"
URINAL
WALL HUNG, FLUSH VALVE
6" 6"
NOTES:
1. FOR CONCRETE BLOCK WALLS, ALL DIMENSIONS SHOWN IN THIS TABLE ARE THE UNITERRUPTED INSIDE DIMENSIONS (NOT OUTSIDE DIMENSIONS).
2. WALL WIDTHS ARE THE MINIMUM REQUIRED FOR FIXTURE INSTALLATION. RISERS MAY REQUIRE ADDITIONAL WALL THICKNESS.
12/31/2019
07/19/1908/16/19
SEAT#7791
#7711