This document is an Addendum No. 1 issued by The Schemmer Associates for the NPS Restroom Remodel and Door Hinge project (Project #09258.004) at Jewel Cave National Monument. The addendum modifies several architectural and mechanical drawings, including changes to door hinges, entry doors, hardware schedules, and plumbing details. Specifically, the architectural modifications include allowing bidders to size up hinges, changing both entry doors to swing out, revising the hardware schedule to remove surface closers, and changing a swing door operator to a power door operator. Mechanical changes include adding a water meter to the water service in Utility 154 and updating water service details and fixture schedules.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
July 25, 2025 Addendum No. 1 - 1 Project #09258.004
DATE: July 25, 2025
FROM: The Schemmer Associates
1044 North 115th Street, Suite 300 Omaha, Nebraska 68154 Phone: (402) 493-4800
TO: Prospective Bidders and Plan Holders
RE: Addendum No. 1 to the Bidding Documents for:
NPS Restroom Remodel and Door Hinge Schemmer Project No. 09258.004
This addendum is issued by the Architect to the Contractor. This Addendum shall be made a part of the Contract Documents. Acknowledge receipt of this Addendum shall be provided on the Bid Form. Failure to do so may subject Bidder to disqualification.
This addendum consists of two (2) pages of written addendum items and four (4) pages of supplemental drawings.
THE SCHEMMER ASSOCIATES INC.
July 25, 2025 Addendum No. 1 - 2 Project #09258.004
DRAWINGS
ARCHITECTURAL
Item No. SA-1 A 03 – Hinges section modified to include the bidder’s option to size up hinges A001 – Text modified to include the bidder’s option to size up hinges A101 – Both Entry Doors to swing out.
A301 – Hardware Schedule edited. Set 1 revised to have no Surface Closet and Swing Door Operator is changed to Power Door Operator, Set 5 eliminated Surface Closer
MECHANICAL
Item No. SM-1 P101 – Water meter was added to the water service in Utility 154.
P401 – Water service detail added, L-1 and L-2 fixture change on schedule.
END OF ADDENDUM NO. 1
1300 w 57th Street | Suite 2 Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C :\U se rs
\e lin eh an
\D oc um en ts \R ev it_ te m p\
-A
R C
H _R
_e lin eh an
BC
9A F.
rv t
RJM
EML
RTG
01/10/2025
009258.004
A 03
ARCHITECTURAL
SPECIFICATIONS
009258004- 2- A 03 ARCHITECTURAL SPECIFICATIONS
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
DATE INITIAL
07/25/2025 EML
2.02 BASIS OF DESIGN -- SWINGING DOORS
A. Medium Stile, Insulating Glazing, Thermally-Broken:
1. Basis of Design: Kawneer 360.
2. Substitutions: Approved Equal.
3. Thickness: 2-1/4 inches.
4. Substitutions: Approved Equal.
2.03 ALUMINUM-FRAMED STOREFRONT
A. Aluminum-Framed Storefront: Factory fabricated, factory finished aluminum framing members with infill, and related flashings, anchorage and attachment devices.
1. Fabrication: Joints and corners flush, hairline, and weatherproof, accurately fitted and secured; prepared to receive anchors and hardware; fasteners and attachments concealed from view; reinforced as required for imposed loads.
2. Construction: Eliminate noises caused by wind and thermal movement, prevent vibration harmonics, and prevent "stack effect" in internal spaces.
3. System Internal Drainage: Drain to the exterior by means of a weep drainage network any water entering joints, condensation occurring in glazing channel, and migrating moisture occurring within system.
4. Expansion/Contraction: Provide for expansion and contraction within system components caused by cycling temperature range of 170 degrees F over a 12 hour period without causing detrimental effect to system components, anchorages, and other building elements.
5. Movement: Allow for movement between storefront and adjacent construction, without damage to components or deterioration of seals.
6. Perimeter Clearance: Minimize space between framing members and adjacent construction while allowing expected movement.
B. Performance Requirements
1. Wind Loads: Design and size components to withstand the specified load requirements without damage or permanent set, when tested in accordance with ASTM E330/E330M, using loads 1.5 times the design wind loads and 10 second duration of maximum load.
a. Member Deflection: Limit member deflection to flexure limit of glass in any direction, with full recovery of glazing materials.
2. Water Penetration Resistance on Manufactured Assembly: No uncontrolled water on interior face, when tested in accordance with ASTM E331 at pressure differential of 8 psf.
3. Air Leakage: 0.06 cfm/sq ft maximum leakage of storefront wall area when tested in accordance with ASTM E283/E283M at 1.57 psf pressure difference.
2.04 COMPONENTS
A. Aluminum Framing Members: Tubular aluminum sections, drainage holes and internal weep drainage system.
1. Glazing Stops: Center.
B. Glazing: See Section 08-8000.
2.05 MATERIALS
A. Extruded Aluminum: ASTM B221 (ASTM B221M).
B. Fasteners: Stainless steel.
C. Sealant for Setting Thresholds: Non-curing butyl type.
D. Glazing Gaskets: Type to suit application to achieve weather, moisture, and air infiltration requirements.
2.06 FINISHES
2.07 HARDWARE
A. Overhead closers with stops.
B. Removable center mullion C. Top/bottom locking system if no center mullion, otherwise a keyed throw bolt system for the few times the doors will be locked.
D. Add thresholds (5) E. Locking cylanders shall be keyed to match Owner's designated keys. Coordinate with Section 08-7100.
F. Weatherstripping: Wool pile, continuous and replaceable; provide on all doors.
G. Sill Sweep Strips: Resilient seal type, retracting, of neoprene; provide on all doors.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify dimensions, tolerances, and method of attachment with other work.
B. Verify that storefront wall openings and adjoining water-resistive and/or air barrier seal materials are ready to receive work of this section.
3.02 INSTALLATION
A. Install wall system in accordance with manufacturer's instructions.
B. Attach to structure to permit sufficient adjustment to accommodate construction tolerances and other irregularities.
C. Provide alignment attachments and shims to permanently fasten system to building structure.
D. Align assembly plumb and level, free of warp or twist. Maintain assembly dimensional tolerances, aligning with adjacent work.
E. Provide thermal isolation where components penetrate or disrupt building insulation.
F. Install sill flashings. Turn up ends and edges; seal to adjacent work to form water tight dam.
G. Where fasteners penetrate sill flashings, make watertight by seating and sealing fastener heads to sill flashing.
H. Use non-expansive spray foam insulation in shim spaces at perimeter of assembly to maintain continuity of thermal barrier.
I. Set thresholds in bed of sealant and secure.
J. Install hardware using templates provided.
K. Install glass and infill panels using glazing method required to achieve performance criteria; see Section 08-8000.
L. Touch-up minor damage to factory applied finish; replace components that cannot be satisfactorily repaired.
M. Set exterior door thresholds with full-width bead of elastomeric sealant at each point of contact with floor providing a continuous weather seal; anchor thresholds with stainless steel countersunk screws.
3.03 TOLERANCES
A. Maximum Variation from Plumb: 0.06 inch per 3 feet non-cumulative or 0.06 inch per 10 feet, whichever is less.
B. Maximum Misalignment of Two Adjoining Members Abutting in Plane: 1/32 inch.
3.04 FIELD QUALITY CONTROL
A. Water-Spray Test: Owner may conduct a water spray quality test of installed storefront components during construction process and before installation of interior finishes.
1. Perform a minimum of two tests in each designated area as indicated on drawings.
2. Conduct tests in each area prior to 10 percent and 50 percent completion of this work.
B. Repair or replace storefront components that have failed designated field testing, and retest to verify performance complies with specified requirements.
3.05 ADJUSTING
A. Adjust operating hardware and sash for smooth operation.
3.06 CLEANING
A. Remove protective material from pre-finished aluminum surfaces.
B. Wash down surfaces with a solution of mild detergent in warm water, applied with soft, clean wiping cloths, and take care to remove dirt from corners and to wipe surfaces clean.
C. Upon completion of installation, thoroughly clean aluminum surfaces in accordance with AAMA 609 & 610.
3.07 PROTECTION
A. Protect installed products from damage until Date of Substantial Completion.
END OF SECTION
SECTION 08-7100 - DOOR HARDWARE
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Hardware forhollow metaldoors.
B. Thresholds.
C. Gasketing.
1.02 ADMINISTRATIVE REQUIREMENTS
A. Coordinate the manufacture, fabrication, and installation of products that door hardware is installed on.
B. Furnish templates for door and frame preparation to manufacturers and fabricators of products requiring internal reinforcement for door hardware.
C. Keying Requirements Meeting:
1. Attendance Required:
a. Contractor.
b. Owner.
c. May be conducted via email or other Owner approved written method.
2. Incorporate "Keying Requirements Meeting" decisions into keying submittal upon review of door hardware keying system including, but not limited to, the following:
3. Record minutes and distribute copies within two days after meeting to participants, with one copy to Architect, Owner, and those affected by decisions made.
4. Deliver established keying requirements to manufacturers.
1.03 SUBMITTALS
A. Product Data: Manufacturer's catalog literature for each type of hardware, marked to clearly show products to be furnished for this project, and includes construction details, material descriptions, finishes, and dimensions and profiles of individual components.
B. Shop Drawings - Door Hardware Schedule: Submit detailed listing that includes each item of hardware to be installed on each door. Use door numbering scheme as included in Contract Documents.
1. Prepared by or under supervision of Architectural Hardware Consultant (AHC).
2. List groups and suffixes in proper sequence.
3. Provide complete description for each door listed.
4. Provide manufacturer name, product names, and catalog numbers; include functions, types, styles, sizes and finishes of each item.
5. Include account of abbreviations and symbols used in schedule.
C. Maintenance Data: Include data on operating hardware, lubrication requirements, and inspection procedures related to preventative maintenance.
1. Submit manufacturer's parts lists and templates.
D. Maintenance Materials and Tools: Furnish the following for Owner's use in maintenance of project.
1. Lock Cylinders: Ten for each master keyed group.
2. Tools: One set of each special wrench or tool applicable for each different or special hardware component, whether supplied by hardware component manufacturer or not.
1.04 QUALITY ASSURANCE
A. Standards for Fire-Rated Doors: Maintain one copy of each referenced standard on site, for use by Architect and Contractor.
B. Installer Qualifications: Company specializing in performing work of the type specified for commercial door hardware with at least three years of documented experience.
C. Supplier Qualifications: Company with certifiedArchitectural Hardware Consultant (AHC)to assist in work of this section.
1.05 DELIVERY, STORAGE, AND HANDLING
A. Package hardware items individually; label and identify each package with door opening code to match door hardware schedule.
1.06 WARRANTY
A. Manufacturer's Warranty: Provide warranty against defects in material and workmanship for period indicated. Complete forms in Owner's name and register with manufacturer.
1. Closers: Five years, minimum.
2. Exit Devices: Three years, minimum.
3. Locksets and Cylinders: Three years, minimum.
4. Other Hardware: Two years, minimum.
PART 2 PRODUCTS
2.01 DESIGN AND PERFORMANCE CRITERIA
A. Provide specified door hardware as required to make doors fully functional, compliant with applicable codes, and secure to extent indicated.
B. Provide individual items of single type, of same model, and by same manufacturer.
C. Provide door hardware products that comply with the following requirements:
1. Applicable provisions of federal, state, and local codes.
2. Accessibility: ADA Standards and ICC A117.1.
3. Applicable provisions of NFPA 101.
4. Fire-Rated Doors: NFPA 80, listed and labeled by qualified testing agency for fire protection ratings indicated, based on testing at positive pressure in accordance with NFPA 252 or UL 10C.
5. Hardware for Smoke and Draft Control Doors: Provide door hardware that complies with local codes, and requirements of assemblies tested in accordance with
UL 1784.
a. Air Leakage Rate: Tested in accordance with UL 1784, with air leakage rate not to exceed 3.0 cfm/sf of door opening at 0.10 inch of water for both ambient and elevated temperature tests.
6. Listed and certified compliant with specified standards by BHMA (CPD).
7. Auxiliary Hardware: BHMA A156.16.
8. Hardware Preparation for Steel Doors and Steel Frames: BHMA A156.115.
9. Hardware Preparation for Wood Doors with Wood or Steel Frames: BHMA A156.115W.
D. Lock Function: Provide lock and latch function numbers and descriptions of manufacturer's series. Refer toDoor Hardware Schedule.
E. Fasteners:
1. Provide fasteners of proper type, size, quantity, and finish that comply with commercially recognized standards for proposed applications.
a. Aluminum fasteners are not permitted.
b. Provide phillips flat-head screws with heads finished to match door surface hardware unless otherwise indicated.
2.02 HINGES
A. Manufacturers:
1. BASIS OF DESIGN: Hager Companies; BB1199: www.hagerco.com
2. Bidder's Option to size up basis of design in case of stripping existing screw holes.
3. Substitutions: Approved Equal.
B. Hinges: Comply with BHMA A156.1, Grade 1.
1. Butt Hinges: Comply with BHMA A156.1 and BHMA A156.7 for templated hinges.
a. Provide hinge width required to clear surrounding trim.
2. Provide hinges on every swinging door.
3. Provide five-knuckle full mortise butt hinges unless otherwise indicated.
4. Provide ball-bearing hinges at each door with closer.
5. Provide non-removable pins on interior outswinging doors.
6. Provide following quantity of butt hinges for each door:
a. Doors From 60 inches High up to 90 inches High: Three hinges.
b. Doors 90 inches High up to 120 inches High: Four hinges.
2.03 EXIT DEVICES
A. Manufacturers:
1.Sargent; an Assa Abloy Group company; 8800 Series: www.assaabloydss.com
2. Von Duprin, an Allegion brand: www.allegion.com
3. Substitutions: Approved Equal.
2.04 MORTISE LOCKS
A. Manufacturers:
1. Best Access Systems, dormakaba Group; 45H Series: www.bestaccess.com
2. Schlage, an Allegion brand; 9456 Series: www.allegion.com
3. Sargent, an Assa Abloy Group; 8200 Series: www.sargentlock.com
4. Substitutions: Approved Equal.
B. Mortise Locks: Comply with BHMA A156.13, Grade 1, Security, 1000 Series.
1. Latchbolt Throw: 3/4 inch, minimum.
2. Deadbolt Throw: 1 inch, minimum.
3. Backset: 2-3/4 inch unless otherwise indicated.
4. Strikes: Provide manufacturer's standard strike for each latchset or lockset with strike box and curved lip extending to protect frame in compliance with indicated requirements.
a. Flat-Lip Strikes: Provide for locks with three piece antifriction latchbolts as recommended by manufacturer.
b. Extra-Long-Lip Strikes: Provide for locks used on frames with applied wood casing trim.
c. Rabbet Front and Strike: Provide on locksets for use with rabbeted meeting rails.
d. Finish: To match lock or latch.
5. Lever Style: Based on Best Access Systems #14 lever.
6. Escutcheons (Roses): Based on Best Access Systems H Rose design.
7. Occupancy Indicator on outside of door. Family Restroom Door Only.
a. Vacant/Occupied.
b. Red/Green.
8. Dummy Trim: Match lever lock trim and escutcheons.
2.05 CLOSERS
A. Manufacturers; Surface Mounted:
1. LCN, an Allegion brand; LCN 4040XP or LCN 4041 Super Smoothee: www.allegion.com
2. Norton or Sargent; an Assa Abloy Group company: www.assaabloydss.com
3. Substitutions: Approved Equal.
B. Closers: Comply with BHMA A156.4, Grade 1.
1. Type: Surface mounted to door.
a. Provide cushion (CUSH) stop feature at scheduled locations.
b. Mounting: Parallel Arm, unless indicated otherwise.
c. Back check: Adjustable, effective between 60 and 85 degrees of door opening.
d. Cover Material: Aluminum metallic paint finish to match hardware finish.
e. Closing Power Adjustment: At least 50 percent more than minimum tested value.
1) Provide separate checking valves for back check, speed and latching adjustment.
f. Drop plates: At aluminum frames provide drop plate as required to attach closure to aluminum frame. Painted finish to match closure cover.
2. Provide door closer on each exterior door.
3. Provide door closer on each fire-rated and smoke-rated door, unless otherwise indicated.
4. At corridor entry doors, mount closer on room side of door.
5. At outswinging doors, mount closer on interior side of door.
2.06 OVERHEAD STOPS AND HOLDERS
A. Manufacturers:
1. Glynn-Johnson, an Allegion brand; 550 Series heavy duty: www.allegion.com
2. Rixson or Sargent; an Assa Abloy Group company: www.assaabloydss.com
3. Substitutions: Approved Equal.
B. Overhead Stops: Comply with BHMA A156.8, Grade 1, for single-acting doors opening to 90 degrees with shock absorber.
1. Provide stop for every swinging door, unless otherwise indicated.
2. Provide without hold open function.
2.07 KICK PLATES
A. Manufacturers:
1. Hiawatha, Inc, an Activar Construction Products Group company: www.activarcpg.com
2. Ives, an Allegion brand: www.allegion.com
3. Substitutions: Approved Equal.
B. Kick Plates: Provide at the entry side of the Utility Room only.
1. BHMA Al56.6; fabricated from 0.050-inch- (1.3-mm-) thick stainless steel; with manufacturer's standard machine or self-tapping screw fasteners.
2. Size: 8 inch high by 2 inch less door width (LDW) on push side of door.
2.08 WALL STOPS
A. Manufacturers:
1. Ives, an Allegion brand; Model WS401: www.allegion.com 2.Rockwood; an Assa Abloy Group company: www.assaabloydss.com
3. Hager Companies: www.hagerco.com
4. Hiawatha, Inc: www.activarcpg.com
5. Substitutions: Approved Equal.
B. Wall Stops: Comply with BHMA A156.16, Grade 1 and Resilient Material Retention Test as described in this standard.
1. Type: Bumper, concave, wall stop.
2. Material: Aluminum housing with rubber insert.
3. Size; 2-1/2-inch diameter, minimum 3/4-inch projection from wall; with back plate for concealed fastener installation
2.09 THRESHOLDS
A. Manufacturers:
1. Dunbarton Corporation: www.dunbarton.com/#sle.
2. Pemko; an Assa Abloy Group company: www.assaabloydss.com
3. Hager Companies: www.hagerco.com
4. National Guard Products, Inc: www.ngpinc.com
5. Substitutions: Approved Equal.
B. Thresholds: Comply with BHMA A156.21.
1. Provide threshold at each exterior door, unless otherwise indicated.
2. Type: Flat surface.
3. Material: Aluminum.
4. Threshold Surface: Fluted horizontal grooves across full width.
5. Field cut threshold to profile of frame and width of door sill for tight fit.
6. Provide non-corroding fasteners at exterior locations.
2.10 WEATHERSTRIPPING AND GASKETING
A. Manufacturers:
1. Reese Enterprises, Inc; Product ID: 815: www.reeseusa.com 2.Pemko; an Assa Abloy Group company: www.assaabloydss.com
3. National Guard Products, Inc: www.ngpinc.com
4. Substitutions: Approved Equal.
B. Gasketing: Comply with BHMA A156.22.
1. Head and Jamb Type: Encased in retainer.
2. Door Sweep Type: Door shoe.
3. Material: Aluminum.
4. Provide gasketing for smoke and draft control doorsthat complies with local codes, requirements of assemblies tested in accordance with UL 1784.
2.11 DRIP CAP
A. Manufacturers:
1. National Guard Products, Inc[<>]: www.ngpinc.com
2. Substitutions: Approved Equal.
B. Product Description
1. Anodized Aluminum Drip Strip
2. Aluminum alloy 6063, T5 temper
3. 2-1/2" wide x 1-1/2" tall
4. #6 x 3/4" stainless steel SMS furnished
5. Screw holes slotted for adjustment
6. Anodized aluminum
2.12 SILENCERS
A. Manufacturers:
1. Ives, an Allegion brand: www.allegion.com
2. Rockwood; an Assa Abloy Group company: www.assaabloydss.com
3. Substitutions: Approved Equal.
B. Silencers: Provide at equal locations on door frame to mute sound of door's impact upon closing.
1. Single Door: Provide three on strike jamb of frame.
2. Pair of Doors: Provide two on head of frame, one for each door at latch side.
3. Material: Rubber, gray color.
2.13 KEY CONTROL SYSTEMS
A. Key Control Systems: Comply with guidelines of BHMA A156.28.
1. Provide keying information in compliance with DHI (KSN) standards.
2. Keying: Grand master keyed.
3. Key to existing keying system.
4. Two (2) keys for each lock.
5. Permanent Keys and Cores: Stamped with applicable key marking for identification. Do not include actual key cuts within visual key control marks or codes.
Stamp permanent keys "Do Not Duplicate."
2.14 FINISHES
A. Finishes: Provide door hardware of same finish, unless otherwise indicated.
1.Primary Finish: 626; satin chromium plated over nickel, with brass or bronze base material (former US equivalent US26D); BHMA A156.18.
2. Secondary Finish: 626; satin chromium plated over nickel, with brass or bronze base material (former US equivalent US26D); BHMA A156.18.
a. Use secondary finish in bathrooms, and other spaces containing chrome or stainless steel finished appliances, fittings, and equipment; provide primary finish on one side of door and secondary finish on other side if necessary.
3. Exceptions:
a. Where base material metal is specified to be different, provide finish that is an equivalent appearance in accordance with BHMA A156.18.
b. Door Closer Covers and Arms: Color as selected by Architect from manufacturer's standard colors unless otherwise indicated.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify that doors and frames are ready to receive this work; and frames are properly installed, and dimensions are as indicated on shop drawings.
3.02 INSTALLATION
A. Install hardware in accordance with manufacturer's instructions and applicable codes.
B. Use templates provided by hardware item manufacturer.
C. Do not install surface mounted items until application of finishes to substrate are fully completed.
D. Door Hardware Mounting Heights: Distance from finished floor to center line of hardware item. As indicated in following list; unless noted otherwise in Door Hardware Schedule or on drawings.
1. Flush Wood Doors: See Section 08-1416.
2. Mounting heights in compliance with ADA Standards:
a. Locksets: 40-5/16 inch.
b. Deadlocks (Deadbolts): 48 inch.
3.03 ADJUSTING
A. Adjust hardware for smooth operation.
B. Adjust gasketing for complete, continuous seal; replace if unable to make complete seal.
3.04 CLEANING
A. Clean finished hardware in accordance with manufacturer's written instructions after final adjustments have been made.
B. Clean adjacent surfaces soiled by hardware installation.
C. Replace items that cannot be cleaned to manufacturer's level of finish quality at no additional cost.
3.05 PROTECTION
A. Do not permit adjacent work to damage hardware or finish.
END OF SECTION
SECTION 08-7113 - POWER DOOR OPERATORS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Operators for swinging doors.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Operators for Swinging Doors:
1. ASSA ABLOY Entrance Solutions: www.besam-usa.com/#sle.
2. Substitutions: Approved Equal.
2.02 POWER DOOR OPERATORS - GENERAL
A. Electrically Operated or Controlled Hardware: Provide necessary power supplies, relays, and interfaces as required for proper operation; provide wiring between control components and to building power connection in compliance with NFPA 70.
B. Comply with ADA Standards for egress requirements.
C. Comply with NFPA 101 and requirements of authorities having jurisdiction; provide units selected for actual door weight and for light pedestrian traffic unless otherwise indicated.
2.03 OPERATORS FOR SWINGING DOORS
A. Door Operator: Electromechanical.
1. Applications: Include operators for single and double doors.
2. Electromechanical Operators: self-contained, gear driven, with release clutch.
3. Speed Control: Variable, field-adjustable opening and closing cycles.
4. Functionality: Full-power open, spring close operation.
a. Full-Power Operators: Comply with BHMA A156.10; safeties required.
1) Comply with UL 325; acceptable evidence of compliance includes UL (DIR) or ITS (DIR) listing or test report by testing agency acceptable to authorities having jurisdiction.
5. Mounting: Surface mounted overhead.
6. Power Supply Units: Self-contained, electrically operated, and independent of door operator.
7. Actuators: Manufacturer's standard.
PART 3 EXECUTION
3.01 INSTALLATION
A. Install equipment in accordance with manufacturer's instructions.
3.02 ADJUSTING
A. Adjust door equipment for correct function and smooth operation.
END OF SECTION
SECTION 08-8300 - MIRRORS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Glass mirrors.
1. Annealed float glass.
1.02 SUBMITTALS
A. Product Data on Mirror Types: Submit structural, physical and environmental characteristics, size limitations, special handling and installation requirements.
1.03 QUALITY ASSURANCE
A. Fabricate, store, transport, receive, install, and clean mirrors in accordance with manufacturer's recommendations.
1.04 FIELD CONDITIONS
A. Do not install mirrors when ambient temperature is less than 50 degrees F.
B. Maintain minimum ambient temperature before, during and 24 hours after installation of glazing compounds.
�125
OS OS
D15
D28 D3
D27
D26
D4
D23
D23D14
D18 D19
D3
D14
D14
D13D13
D3
D3
D16
D16
D16
D20
D6 D6
D24
D24
D5 D5
D7
D7
D10
D11
D5
D17 D17
D17 D17
D7
D7
D5
D11
D8 D9
D8
D25
D25
D3
D3
D3
D3
D3
D3
D11 D12 D12
D29
D29
D29 D29
D29
D30
D30
D30
D30D30
D31
D31
D31
D31
D32D29
D4
D23
D10
D2
D1
D1
D1
D1
D1D1
1300 w 57th Street | Suite 2 Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C :\U se rs
\e lin eh an
\D oc um en ts \R ev it_ te m p\
-A
R C
H _R
_e lin eh an
BC
9A F.
rv t
RJM
EML
RTG
01/10/2025
009258.004
A001
DEMOLITION FLOOR PLANS
& PHOTOS
009258004- 2- A001 DEMOLITION FLOOR PLANS & PHOTOS
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
REF. DEMO NOTES ( ):DX
D1 REMOVE EXISTING GYPSUM CEILING, GWB BACKING AND ATTIC
INSULATION, AND DEVICES ATTACHED OR INSTALLED WITH IT.
D2 REMOVE EXISTING TONGUE & GROOVE CEILING, FRAMING AND ATTIC
INSULATION AND DEVICES ATTACHED OR INSTALLED WITH IT.
D3 REMOVE EXISTING WOOD STUD WALL.
D4 REMOVE EXISTING WOOD STUD & BRICK WALL.
D5 REMOVE ALL EXISTING PLUMBING FIXTURES. REFER TO MECHANICAL.
D6 REMOVE ALL EXISTING SOAP DISPENSERS.
D7 REMOVE ALL EXISTING HAND DRYERS & SALVAGE TO OWNER.
D8 REMOVE ALL EXISTING TOILET PAPER DISPENSERS.
D9 REMOVE ALL EXISTING SANITARY DISPOSALS.
D10 REMOVE ALL EXISTING FLOOR DRAINS. REFER TO MECHANICAL.
D11 REMOVE ALL EXISTING TOILET PARTITIONS AND URINAL SCREENS IN
THEIR ENTIRETY.
D12 REMOVE EXISTING CERAMIC TILE FLOOR.
D13 REMOVE EXISTING HOLLOW METAL DOOR, FRAME, & ASSOCIATED
HARDWARE. SALVAGE AUTOMATIC OPENER HARDWARE AND REUSE.
D14 REMOVE EXISTING TONGUE & GROOVE DOOR & HARDWARE.
D15 REMOVE EXISTING ALUMINUM STOREFRONT DOOR FRAME, GLAZING &
ASSOCIATED HARDWARE. SALVAGE HARDWARE.
D16 REMOVE EXISTING VCT FLOORING & ADHESIVE.
D17 REMOVE EXISTING MIRRORS.
D18 REMOVE EXISTING MOP SINK. REFER TO MECHANICAL.
D19 REMOVE EXISTING WATER HEATER. REFER TO MECHANICAL.
D20 REMOVE EXISTING CARPET TILE & ADHESIVE.
D23 REMOVE WOOD PANELING.
D24 REMOVE EXISTING CHANGING STATION.
D25 REMOVE EXISTING GRAB BARS.
D26 REMOVE EXISTING BASE CABINETS, COUNTERTOP, & UPPER CABINETS.
SALVAGE FOR OWNER.
D27 REMOVE EXISTING CASED OPENING.
D28 REMOVE EXISTING HOLLOW METAL DOOR, FRAME, & HARDWARE
(KEYPAD). SALVAGE FOR REUSE.
D29 REMOVE ALL EXISTING DRYWALL, MOISTURE BARRIER AND INSULATION
FROM INTERIOR PERIMETER WALLS.
D30 REMOVE EXISTING CONCRETE SLAB THROUGHOUT.
D31 EXISTING WINDOW TO REMAIN.
D32 REMOVE GLAZING, THIS WINDOW ONLY.
KEY PLAN NORTH
A
B
SCALE: 1/4" = 1'-0"
FIRST FLOOR AREA 'A' - DEMOLITION
SCALE: 1/8" = 1'-0"
FIRST FLOOR AREA 'B' - DEMOLITION
SCALE: 1/4" = 1'-0"
FIRST FLOOR AREA 'A' - DEMOLITION REFLECTED CEILING PLAN
CONDITION OCCURS AT THREE FLOOR LEVELS: 6 HINGES PER PAIR OF DOORS.
REMOVE AND REPLACE A TOTAL OF 36 FAILING
AIRLOCK 5 KNUCKLE SQUARE BUTT STAINLESS
STEEL HINGES AT A TOTAL OF 4 DOORS (2 PAIRS)
WITH 3 HINGES EACH AT 3 DIFFERENT LEVELS OF
ELEVATOR DOORS. IT IS POSSIBLE THAT SOME
THREADS MAY BE STRIPPED. IN THIS CASE,
INSTALL SS TAP AND DYE THREADS OR WELDED
BACK PLATES. CONFIRM LOCATION AND
CONDITION PRIOR TO REMOVAL. BIDDER'S OPTION
TO SIZE UP HINGES IN THE CASE OF STRIPPING.
REMOVE AND REPLACE A TOTAL OF 36 FAILING
AIRLOCK 5 KNUCKLE SQUARE BUTT STAINLESS
STEEL HINGES AT A TOTAL OF 4 DOORS (2 PAIRS)
WITH 3 HINGES EACH AT 3 DIFFERENT LEVELS OF
ELEVATOR DOORS. IT IS POSSIBLE THAT SOME
THREADS MAY BE STRIPPED. IN THIS CASE,
INSTALL SS TAP AND DYE THREADS OR WELDED
BACK PLATES. CONFIRM LOCATION AND
CONDITION PRIOR TO REMOVAL. BIDDER'S OPTION
TO SIZE UP HINGES IN THE CASE OF STRIPPING.
ONLY ONE DOOR CAN BE COMPLETED AT A TIME
TO KEEP THE OTHER ELEVATOR OPERATIONAL
AND ALL WORK TO BE COORDINATED WITH THE
NPS ON SITE.
THE INTENT OF THE FOLLOWING DEMOLITON NOTES IS TO EXPRESS THE
GENERAL SCOPE REQUIRED TO ACHIEVE A COMPLETE INTERIOR DEMOLITION
WHILE RETAINING THE ROOF & EXTERIOR SYSTEMS
DATE INITIAL
07/25/2025 EML
�150-C
�1
-A
�153 15
�1
-B
FEC
OS
OS OS
OS
OS
OS
�150-C
�1
-A
�153 15
�1
-B
SL
O
PE
1"
SLOPE
1"
SLOPE
1"
SL
O
PE
1"
SL
O
PE
1"
SLOPE
1"
SLOPE
1"
SL
O
PE
1"
SLO
PE
1"
SLOPE
1"
SLOPE
1"
SLOPE1"
SL
O
PE
1"
SL
O
PE
1"
SLOPE
1"
SL
O
PE
1"
SLOPE
1"
SL
O
PE
1"
SL
O
PE
1"
SLOPE
1"
SL
O
PE
1"
SLOPE
1"
SL
O
PE
1"
SLOPE
1"
SLOPE
1"
SL
O
PE
1"
SLOPE
1"
SL
O
PE
1"
SLOPE
1"
SLOPE
1"
SL
O
PE
1" SLOPE
1"
LIGHT FIXTURES
(SEE ELECTRICAL)
GRILLES AND DIFFUSERS
(SEE MECHANICAL)
GYPSUM BOARD CEILING
LEGEND:
FOR CEILING HEIGHTS, SEE ROOM FINISH SCHEDULE
FIRE ALARM STROBE, SEE ELEC
FIRE ALARM SPEAKER, SEE ELEC
FIRE ALARM SPEAKER STROBE,
SEE ELEC
OCCUPANCY SENSOR, SEE ELEC
EXIT SIGN, SEE ELEC
FIRE ALARM HORN, SEE ELEC
FIRE ALARM HORN STROBE,
SEE ELEC
SMOKE DETECTOR, SEE ELEC
SPEAKER, SEE ELEC
F
F S
F S
OS
F
F
S
S
A501 79
A501 111
A50115
FAMILY
WOMEN
LOBBY
MEN
A5015 3
C
A
C
A
C
B
B
C
C
'-4
/2
7'
-8
3' -5
'-9
/4
3'
-1
/8
3'-6"
3'-0" 7'-0"
2'-2 1/4" 2'-9 3/4" 1'-11" 5'-4" 4'-9"
8 1/2"
7'-7 1/2"AL F1
UTILITY
154B
3 3
MECH CHASE
7' -6
/8
A301
A
A301
A
C
8 1/2"
A501
20 TA-7
ADD BACKING FOR
GRAB BAR
ADD BACKING FOR
GRAB BAR
ADD BACKING FOR
WATER HEATER
A.F.F.
5/8" GWB on Wood Stud
8' - 6"
A.F.F.
5/8" GWB on Wood Stud
8' - 6"
A.F.F.
5/8" GWB on Wood Stud
8' - 6"
WOMEN
MEN
FAMILY
LOBBY
A.F.F.
5/8" GWB on Wood Stud
8' - 6"
A.F.F.
5/8" GWB on Wood Stud
8' - 6"
A B C
CEILING
8'-6" A.F.F.
7 1/4" 4 1/4" 4 7/8"
5'- 7"
Ø
10"
ALLOWABLE OVERLAP
ADA CLEARANCES ARE CRITICAL. ONCE
MARKED ON THE FLOOR AND PRIOR TO
FRAMING, CONFIRM THAT CRITICAL
DIMENSIONS ARE ACHIEVED.
FAMILY
WOMEN
LOBBY
MEN
UTILITY
MECH CHASE
FLAT
FLAT
EXISTING STRUCTURE ABOVE
WITH NEW R-42 BLOWN-IN INSULATION
VAPOR BARRIER
GYPSUM BOARD CEILING
WOOD STUDS 16" O.C.CEILING
8'-6" A.F.F.
2X NEEDED AT BOTH SIDES OF THE CORNERS
1300 w 57th Street | Suite 2 Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C :\U se rs
\e lin eh an
\D oc um en ts \R ev it_ te m p\
-A
R C
H _R
_e lin eh an
BC
9A F.
rv t
RJM
EML
RTG
01/10/2025
009258.004
A101
FLOOR PLAN & REFLECTED
CEILING PLAN
009258004- 2- A101 FLOOR PLAN & REFLECTED CEILING PLAN
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
2 WALL-MOUNTED WATER CLOSET WITH FLUSH VALVE. REFER TO
PLUMBING.
3 WALL-MOUNTED WATER CLOSET WITH FLUSH VALVE, ACCESSIBLE
HEIGHT. REFER TO PLUMBING.
4 URINAL & FLUSH VALVE. REFER TO PLUMBING.
5 SINK. REFER TO PLUMBING.
6 HAND DRYER AND SOAP DISPENSER INTEGRATED INTO WASH BAR.
REFER TO ELECTRICAL AND PLUMBING.
8 ADULT CHANGING TABLE.
10 URINAL SCREEN WITH CONTINUOUS MOUNTING BRACKET.
11 TOILET PARTITION PANEL AND DOOR - CEILING HUNG.
13 FLOOR DRAIN. REFER TO PLUMBING.
19 CEILING ACCESS HATCH 2'-3" X 2'-3".
20 GYPSUM WALL BOARD, VAPOR BARRIER AND INSULATION TO INTERIOR
SIDE OF PERIMETER WALLS.
22 FIRE EXTINGUISHER AND CABINET.
24 SLAB JOINT.
25 30" X 22" CEILING ACCESS PANEL. FIELD VERIFY LOCATION BETWEEN
STRUCTURAL MEMBERS.
26 HEATER. REFER TO MECHANICAL. REFERENCED PLAN NOTES
27 ADA PUSH BUTTON DOOR OPENER, SEE ELECTRICAL.
A PROVIDE & MAINTAIN 2 ADA ACCESSIBLE AND 6 STANDARD PORTABLE
TOILETS WITH HAND SANITATION DURING CONSTRUCTION ONLY.
CONFIRM LOCATION WITH OWNER. SEE COVER SHEET FOR LOCATIONS
AND SPECIFICATIONS FOR DETAILS AND REQUIREMENTS.
REF. NOTES ( ):X
KEY PLAN NORTH
A
SCALE: 1/4" = 1'-0"
FIRST FLOOR AREA 'A'
SCALE: 1/4" = 1'-0"
FIRST FLOOR AREA 'A' - REFLECTED CEILING
TYPE WIDTH
A 0' - 7 1/4" 6" MET FRAME GWB BOTH SIDES
B 0' - 4 1/4" MET FRAME GWB ONE SIDE
C 0' - 4 3/4"
C 0' - 4 7/8" MET FRAME GWB BOTH SIDES
SCALE: 1/4" = 1'-0"
PARTITION TYPES
SCALE: 1/4" = 1'-0"
ADA TURNING RADIUS KEY
NOT TO SCALE
FIRST FLOOR AREA 'A' SLAB LAYOUT
DATE INITIAL
07/25/2025 EML
NOT TO SCALE
CEILING DETAIL
HM : F1
2"
SE
E
SC
H
ED
U
LE
2" 3'-0" 2"
SE
E
SC
H
ED
U
LE
SEE SCHEDULE
HM : F
7' -1
1/
2" V
.I.
F.
2 1/2"3'-0"2 1/2"3'-0"2 1/2"
IG-2 IG-2
6'-7 1/2" V.I.F.
1/
2" 7'
-8
REMOVABLE CENTER
MULLION
HOLLOW METAL
FRAME
DOOR - SEE SCHEDULE
SEALANT
EACH SIDE
METAL STUD
HEADER
HOLLOW METAL
FRAME WITH 3
ANCHORS PER JAMB
SEALANT
EACH SIDE
DOUBLE STUDS
AT JAMB
DOOR - SEE SCHEDULE
SEALANT - EACH SIDE
ALUMINUM STOREFRONT FRAME
EXISTING
SEALANT
ALUMINUM FRAME
SEALANT
5/8" GYPSUM
BATT INSULATION
EXISTING
(1 0"
M
IN
SE
E
D O
O R
T
YP
E
ALUM DOOR -
SEE SCHED.
ALUM
THRESHOLD SET
IN BED OF
SEALANT
SEALANT AT TOP AND BOTTOM
5/8" GYPSUM
5/8" GYPSUM CEILING
EXISTING BLOCKING
EXISTING BLOCKING
CAVITY FOAMED IN
PLACE INSULATION
EXISTING
EXTERIOR FINISH &
SHEATHING
EXISTING
WINDOW - SEAL
SASH TO FRAME
5/8" GYPSUM
SEALANT ON ALL 4
SIDES OF PERIMETER
OF WINDOW OPENING
5/8" GYPSUM
GYPSUM CEILING
EXISTING BLOCKING
EXISTING BLOCKING
FOAMED IN PLACE
INSULATION IN
CAVITY
EXISTING
EXTERIOR FINISH &
SHEATHING
INSTALL OPAQUE
INSULATED PANEL
IN EXISTING
WINDOW SASH
KRAFT-FACED
BATT INSULATION
EXISTING
WINDOW - SEAL
SASH TO FRAME
EXISTING SOFFIT
PANEL
HOLLOW METAL
FRAME WITH 3
ANCHORS PER JAMB
SEALANT
EACH SIDE
DOUBLE STUDS
AT JAMB
DOOR - SEE SCHEDULE
1300 w 57th Street | Suite 2 Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C :\U se rs
\e lin eh an
\D oc um en ts \R ev it_ te m p\
-A
R C
H _R
_e lin eh an
BC
9A F.
rv t
RJM
EML
RTG
01/10/2025
009258.004
A301
SCHEDULES, DOOR AND
WINDOW DETAILS
009258004- 2- A301 SCHEDULES, DOOR AND WINDOW DETAILS
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
DOOR SCHEDULE
DOOR NO.
DOOR SIZE DOOR FRAME DETAIL
SET NO LABEL REMARKSWIDTH HEIGHT MATL & TYPE FINISH GLASS MATL & TYPE FINISH HEAD JAMB JAMB SILL
005 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
006 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
015 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
016 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
123 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
126 PR 3' - 0" 7' - 0" SS : EXIST - - G-2 SS. : EXIST - - - - - - - - - - 6 - - EXISTING DOOR AND FRAME - REPLACE
HINGES.
150 -A 3' - 0" 7' - 8" AL : FG - - IG-2 AL� : F1 - - 4/A301 5/A301 5/A301 6/A301 1 - - ADA OPERATOR, REMOVABLE CENTER
MULLION
150 -B 3' - 0" 7' - 8" AL : FG - - IG-2 AL� : F1 - - 4/A301 5/A301 5/A301 6/A301 1 - - ADA OPERATOR, REMOVABLE CENTER
MULLION
150 -C 3' - 0" 7' - 0" HM : F - - - - HM� : F1 PNT-1 2/A301 3/A301 3/A301 - - 2 - - RELOCATED SALVAGE - KEYPAD
153 3' - 0" 7' - 0" HM : F - - - - HM� : F1 PNT-1 2/A301 3/A301 3/A301 - - 3 - -
154 2' - 6" 7' - 0" HM : F - - - - HM� : F1 PNT-1 2/A301 3/A301 3/A301 - - 4 - -
155 1' - 3" 7' - 0" HM : F - - - - HM� : F1 PNT-1 2/A301 1/A301 1/A301 - - 5 - -
SCALE: 1/4" = 1'-0"
DOOR FRAME TYPES
SCALE: 1/4" = 1'-0"
DOOR PANEL TYPES
SCALE: 1/4" = 1'-0"
AL F1
SCALE: 1 1/2" = 1'-0"
2 HM DOOR HEAD @ MS
SCALE: 1 1/2" = 1'-0"
3 HM DOOR JAMB @ MS
SCALE: 1 1/2" = 1'-0"
4 AL DOOR HEAD
SCALE: 1 1/2" = 1'-0"
5 AL DOOR JAMB
GLASS TYPES
G-2 1/4" CLEAR, TEMPERED FLOAT GLASS
IG-2 1" INSULATED, TINTED LOW-E GLASS, TEMPERED
SCALE: 1 1/2" = 1'-0"
6 AL DOOR SILL
SCALE: 3/4" = 1'-0"
7 EXISTING WINDOW
SCALE: 3/4" = 1'-0"
8 MAPES PANEL
Hardware Schedule
Set 1 Exit Device Entry Lockset Continuous Hinge Power Door Operator OH Stop Sweep Threshold Drip Cap Weatherstripping
Set 2 Five Knuckle Hinge Surface Closer Threshold Weatherstripping Wall Stop Silencer Salvaged Keypad
Set 3 Privacy Lockset ADA Occupancy Indicator Five Knuckle Hinge Surface Closer Wall Stop Silencer
Set 4 Storeroom Lockset Five Knuckle Hinge Kick Plate Silencer Wall Stop
Set 5 Storeroom Lockset Five Knuckle Hinge Silencer Wall Stop
Set 6 Elevator – Air Locks Hager Model BB1199
DATE INITIAL
07/25/2025 EML
SCALE: 1 1/2" = 1'-0"
1 HM DOOR JAMB @ MECH CHASE
M
(E) 4" VTR
BELOW FLOORBELOW FLOOR
BELOW FLOOR
BELOW FLOOR
BELOW FLOOR
1/
2"1 1/
4"
4 4
BELOW FLOOR
(E) WALL HYDRANT
BELOW FLOOR
BELOW FLOOR
(TYP.)
(TYP.)
WC-2 WC-2
WC-1 WC-1
EWC-1
WC-1
WC-1
UR-1
UR-1
1/
2"1 1/
4"
L-1
L-1
MEN
151 WOMEN
FAMILY
UTILITY
BELOW FLOOR
BELOW FLOOR
BELOW FLOOR
BELOW FLOOR
L-2
WC-2
2 1/2" 1 1/4"
1/
2" 2"
1 1/2" (TYP.)3/4" (TYP.)
2"
1/2"
1 1/2"
1"
1"
P101
INCOMING WATER FROM METEROUTGOING WATER TO
REST OF BUILDING
LOBBY
CORRIDOR
117A
OFFICE
HB-1
L-1
L-1
L-1 L-11"
3/4" 3/4" 1/2"
1/2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
(TYP.)
(TYP.)
(TYP.)
2 2
2"
2" 1"
1/2"
1/
2"
1/2"
1/ 2"
1/2"
1/ 2"
BELOW
FLOOR
WH-1
HB-1
HB-1
3/4"
3/4"
FD-1
FD-1
FD-1
FD-1
FD-1FD-1
UTILITY
MS-1
1-1/4" DCW BELOW FLOOR
2-1/2" DCW BELOW FLOOR
EWH-1
2-1/2" INCOMING DCW -
PROVIDE ISO VALVE IN RISE
1-1/4" OUTGOING DCW TO EXISTING SPACE -
PROVIDE ISO VALVE IN DROP
2"
TP-1
DWCP-1
DWET-1
1/ 2"
1/
2"
1/ 2"
1/ 2"
3/4"
1"
1" 1/ 2"
1/2"
3/ 4"
1"
3/ 4"
2-1/2"
FD
-1
WC-2 WC-2
WC-1 WC-1
L-1 L-1
EWC-1
FCO
CO
WC-1
WC-1
UR-1
UR-1
L-1 L-1
L-1 L-1
(E) 4" VTR
MEN
WOMEN
FAMILY
UTILITY
L-2
WC-2
P101
LOBBY
CORRIDOR
117A
OFFICE
2 2
FD-1
FD-1 FD-1
FD-1
FD-1
FD-1
1300 w 57th Street | Suite 2
Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs
\z b e n n e tt \D o c u m e n ts
\R e v it te m p \0
-M
E C
H R z b e n n e tt J T
T G
W .r v t
ZSB
ZSB
JEK
12/05/2024
009258.004
P101
FLOOR PLAN - PLUMBING
009258004- 5- P101 FLOOR PLAN - PLUMBING
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
REF. NOTES ( ):X
1 INSTALL NEW WALL MOUNTED WATER CLOSETS WC-1, WC-2 (ADA), WALL HUNG URINALS,
UR-1, AND FLOOR DRAINS, FD-1, AS SHOWN.
2 INSTALL NEW WALL HUNG THREE PERSON LAVATORY SYSTEM AND WASHBAR FAUCETS, L-1.
INSTALL SINGLE SET OF 3/4" DCW AND DHW FOR EACH THREE PERSON SYSTEM AND
CONNECT TO BRADLEY WATER SUPPLY ASSEMBLY AND PROVIDE POINT OF USE MIXING
VALVE.
3 INSTALL NEW WALL HUNG SINGLE PERSON LAVATORY SYSTEM AND WASHBAR FAUCET, L-2.
CONNECT 1/2" DCW AND DHW TO BRADLEY WATER SUPPLY ASSEMBLY AND PROVIDE POINT
OF USE MIXING VALVE.
4 INSTALL NEW ELECTRIC WATER COOLER, EWC-1
5 INSTALL NEW MOP SINK, MS-1.
6 INSTALL NEW ELECTRIC WATER HEATER, EWH-1, DOMESTIC WATER CIRCULATING PUMP,
DWCP-1, AND DOMESTIC WATER EXPANSION TANK, DWET-1, PER MANUFACTURER'S
RECOMMENDATIONS. INSTALL EWH-1 ON SHELF ABOVE MS-1, SEE DETAIL ON P401 FOR
FURTHER INFO.
7 INSTALL AUTOMATIC TRAP PRIMER, TP-1, PER MANUFACTURERS RECOMMENDATIONS.
CONNECT 1/2" DCW PIPE TO FLOOR DRAINS TRAP PRIMER CONNECTION POINT.
8 PROVIDE ISOLATION VALVE IN EACH TAP OFF HEADER.
9 TIE INTO EXISTING SANITARY MAIN BELOW THE FLOOR IN LOCATION SHOWN.
10 TIE INTO EXISTING 4" VTR IN LOCATION SHOWN.
REF. DEMO NOTES ( ):X
1 REMOVE EXISTING FLOOR MOUNTED WATER CLOSET AND ASSOCIATED PIPING AS SHOWN.
2 REMOVE EXISTING URINAL AND ASSOCIATED PIPING AS SHOWN.
3 REMOVE EXISTING WALL HUNG LAVATORY AND ASSOCIATED PIPING AS SHOWN, INCLUDING
PIPING IN THE WALL.
4 REMOVE EXISTING FLOOR DRAIN AND ASSOCIATED PIPING AS SHOWN.
5 REMOVE EXISTING MOP SINK AND ASSOCIATED PIPING AS SHOWN.
6 REMOVE EXISTING ELECTRIC WATER HEATER AND ASSOCIATED PIPING AS SHOWN.
7 REMOVE ALL BELOW GRADE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN.
8 EXISTING VTR TO REMAIN. REMOVE VENT PIPING TO A POINT JUST BELOW ROOF DECKING
AND PREPARE FOR NEW CONNECTION.
9 DEMOLITION WORK TO INCLUDE FULL REMOVAL OF PLUMBING FROM WALL TO WALL AND
BELOW ROOF ASSEMBLY TO BELOW SLAB, WITHIN AREA OF SCOPE. SEE ARCH FOR DETAILS
ON DRYWALL AND INSULATION REMOVAL IN EXTERIOR WALLS FOR FULL REMOVAL OF
PIPING.
10 COORDINATE CUTTING AND PATCHING OF ALL WALLS, FLOORS, CEILING, AND ROOF WITH GC
WHERE REQUIRED. FINAL FINISHES BY GC.
11 REMOVE EXISTING WALL HYDRANT AND ASSOCIATED PIPING AS SHOWN. COORDINATE
DOWNTIME OF THE WALL HYDRANT TO PREVENT DISRUPTION OF WATER TO THE TRAILER
RESTROOMS.
SCALE: 1/4" = 1'-0"
FIRST FLOOR DEMOLITION PLAN - PLUMBING
SCALE: 1/4" = 1'-0"
FIRST FLOOR PLAN - DOMESTIC WATER - PLUMBING
SCALE: 1/2" = 1'-0"
ENLARGED UTILITY 154 ROOM - PLUMBING
SCALE: 1/4" = 1'-0"
FIRST FLOOR PLAN - SANITARY - PLUMBING
KEY PLAN NORTH
A
DATE INITIAL
07/25/2025 ZSB
7/25/25
BRASS
PLUG COVER PLATE, SEE
SPECIFICATIONS
SLEEVE
TEST TEE
MACHINE
SCREW
FINISHED WALL
LINE
CO
FERRULE AND BRASS PLUG
CO
CO
BRASS
PLUG
TEST TEE
SLEEVE
FERRULE AND COUNTERSUNK
BRASS PLUG
FCO
EPOXY FLOOR
FLOOR DRAIN
SLAB ON-GRADE
APPLICATIONS
D H
W
D C
W
SHUT-OFF VALVE
HOSE END DRAIN VALVE
3/4" PLYWOOD
2X4 WOOD FRAMED
SUPPORT STRUCTURE
TEMP AND PRESS RELIEF
VALVE, PIPE TO SINK OR FLOOR
DRAIN BELOW
FRONT VIEW SIDE VIEW
L-1
L-2
FCO
WC-2
EWC-1
MS-1
WC-2
WC-1
WC-1
WC-1
CO
L-1
WC-1
WC-1
WC-2
WC-1
2"
2"
2"
1 1/2"
4"
4"
2"
2"
2"
2"
2"
3"
3"
(E) 4" VTR
4"
4"
4"
2"
3" 2"
3"
4"
4"
2"
2"
3" 1 1/2"
2"
4"
4"
4"
4"
2"
2"
2"
2"
4"
2"
2"
3"
2"
2"
2"
1 1/2"
2"
2"
2"
2" 1 1/2"
2"
3"
2"
2"
2"
2"
2"
2"
3"
2"
2"
2"
2" 2"
2"
2"
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
FD-1
2"
PIPING
MAIN
FIXTURE
(TYP.)
ARRESTOR
MUST BE
ACCESSIBLE
VALVE
WATER HAMMER
ARRESTOR, SEE
CHART BELOW.
WATER HAMMER ARRESTOR SIZE
FIXTURE UNITS
NOTE:
1. IF INCOMING PRESSURE IS GREATER THAN 65 PSI, ARRESTOR SIZE SHALL BE INCREASED BY 1 SIZE.
Y > 20' PROVIDE SECOND ARRESTOR
6" MAX
"Y"
A
1-11 12-32 33-60 61-113 114-154 155-330
B C D E F
ISOLATION
VALVE (TYP.)
PRESSURE
GAUGE
PUMP
SUPPORT PUMP SEPARATE
FROM PIPINGCHECK
VALVE
STRAINER
UNION
(TYP.)
2-1/2"
2-1/2" CW
PIPE TO
FLOOR
DRAIN
RPZ BACKFLOW
PREVENTER
2-1/2"" CW TO DOMESTIC
WATER SYSTEM
3" METER
GATE VALVE
(TYP.)
8" MIN.
PRV
STRAINER WITH BLOW DOWN
VALVE
1300 w 57th Street | Suite 2
Sioux Falls, SD 57108
(605) 332-7850 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
238608 / 80005
80005
C U s e rs
\z b e n n e tt \D o c u m e n ts
\R e v it te m p \0
-M
E C
H R z b e n n e tt J T
T G
W .r v t
ZSB
ZSB
JEK
12/05/2024
009258.004
P401
SCHEDULES, DETAILS, &
RISERS - PLUMBING
009258004- 5- P401 SCHEDULES, DETAILS, & RISERS - PLUMBING
RESTROOM REMODEL & DOOR HINGE
JEWEL CAVE NATIONAL MONUMENT
CUSTER, SD
6. PROVIDE WITH TEE KEY FOR KEYED OPERATION.
5. PROVIDE WITH TRAP PRIMER CONNECTION POINT.
4. PROVIDE WITH 8 OUTLET MANIFOLD.
3. PROVIDE WITH WALL CARRIER.
2. PROVIDE 1/4 TURN ANGLE STOPS AND CHROME PLATED SUPPLY LINES AT PLUMBING FIXTURE.
NOTES: 1. PROVIDE WITH BRADLEY WASHBAR WATER SUPPLY ASSEMBLY, DRAIN ASSEMBLY, AND MIXING VALVE
WH-1 WALL HYDRANT (FREEZELESS) -- 3/4" -- 36" A.F.F. --- WOODFORD MODEL B65 --- --- -- ---
WC-2 WATER CLOSET, ADA, WALL MOUNTED, FLUSH VALVE, HARD WIRED SENSOR -- 1" 4" 2" -- 17" A.F.F. 1.6 GPF SLOAN ST-2459 SLOAN ROYAL 111 ESS-1.6 BEMIS 1955SSCT -- 3
WC-1 WATER CLOSET, WALL MOUNTED, FLUSH VALVE, HARD WIRED SENSOR -- 1" 4" 2" -- 15" A.F.F. 1.6 GPF SLOAN ST-2459 SLOAN ROYAL 111 ESS-1.6 BEMIS 1955SSCT -- 3
UR-1 URINAL, ADA, HARD WIRED SENSOR --- 3/4" 2" 1-1/2" -- SEE ARCH 1.0 GPF SLOAN SU-1009 SLOAN ROYAL180 ESS-1.0 --- -- 3
TP-1 TRAP PRIMER, AUTOMATIC, HARD WIRED --- 1/2" --- --- --- 36" A.F.F. --- JAY R. SMITH 270SM --- --- --- 4
MS-1 MOP SINK, 20"X16" 1/2" 1/2" 2" 2" --- FLOOR 2.0 GPM REGENCY 600SM16206 ZURN Z843M1 --- --- ---
L-2 LAVATORY, HARD WIRED SENSOR, WALL HUNG SYSTEM 1/2" 1/2" 2" 1-1/2" -- SEE ARCH 0.5 GPM BRADLEY VERGE LVQD1 BRADLEY WASHBAR WB1 --- --- 1,2
L-1 LAVATORY, HARD WIRED SENSOR, WALL HUNG SYSTEM 1/2" 1/2" 2" 1-1/2" --- SEE ARCH 0.5 GPM BRADLEY VERGE LVQD3 BRADLEY WASHBAR WB1 --- --- 1,2
HB-1 HOSE BIBB --- 3/4" --- --- --- 12" A.F.F. --- WOODFORD MODEL 17 --- --- --- 6
FD-1 FLOOR DRAIN, ROUND -- -- 2" 2" -- FLOOR --- J.R. SMITH 2005-NB-A -- -- -- 5
EWC-1 ELECTRIC WATER COOLER, DUAL LEVEL, BOTTLE FILLER --- 1/2" 2" 1-1/2" --- SEE ARCH 8.0 GPH ELKAY LZSTL8WSLP --- --- --- ---
HOT WATER COLD... WASTE VENT OTHER FIXTURE FAUCET/FLUSH VALVE ACCESSORY #1 ACCESSORY #2 REMARKSMARK DESCRIPTION
FIXTURE CONNECTIONS
MOUNTING HEIGHT FLOW RATE
MANUFACTURER AND MODEL NUMBER
PLUMBING FIXTURE SCHEDULE
SCALE: NOT TO SCALE
TYPICAL CLEANOUT DETAIL
SCALE: NOT TO SCALE
FLOOR DRAIN DETAIL
SCALE: NOT TO SCALE
WATER HEATER ON SHELF PIPING DETAIL
NOT TO SCALE
SANITARY RISER
2. PROVIDE (2) 2,500 WATT HEATING ELEMENTS WITH SIMULATANEOUS OPERATION.
NOTES: 1. MOUNT ON SHELF ABOVE MOP SINK WITH WALL BRACKET.
EWH-1 UTILITY 154 37 40 140 20 5 208 1 BRADFORD WHITE RE240LN6 1,2
KW VOLTS PHMARK LOCATION
STORAGE
CAPACITY EWT (°F) LWT (°F)
RECOVERY
(GPH)
ELECTRICAL DATA
BASIS OF DESIGN REMARKS
ELECTRIC WATER HEATER SCHEDULE
NOTES: 1. SUPPORT EXPANSION TANK FROM STRUCTURE; DO NOT SUPPORT WITH PIPING.
DWET-1 DHW UTILITY 154 DIAPHRAGM 2 200 150 AMTROL ST-5 ---
MARK SERVES LOCATION TYPE
TANK SIZE
(GALLONS)
TEMP RANGE
(°F)
MAX OPER.
PRESSURE (PSIG) BASIS OF DESIGN REMARKS
EXPANSION TANK SCHEDULE
NOTES: 1. PROVIDE WITH AQUASTAT AND 7 DAY PROGRAMMABLE TIMER.
DWCP-1 UTILITY 154 DHWR INLINE 1 10 3250 1/8 120 1 TACO IL009 1
RPM HP VOLTS PHMARK LOCATION SERVES TYPE FLOW GPM HEAD FT WG
ELECTRICAL DATA
BASIS OF DESIGN REMARKS
PUMP SCHEDULE
SCALE: NOT TO SCALE
FLUSH VALVE WATER HAMMER ARRESTOR DETAIL
SCALE: NOT TO SCALE
IN-LINE PUMP DETAIL
DATE INITIAL
07/25/2025 ZSB
SCALE: NOT TO SCALE
DOMESTIC WATER SERVICE PIPING SCHEMATIC
7/25/25