B09_Amendment_0001_Atch_1_Questions_and_Answers_0001.pdf

PDF 123 KB Posted

Attached to
Fort Union Trading Post NHS Wastewater System Impr Federal contract opportunity
Solicitation number
140P6324B0004
Issued by
Department of the Interior National Park Service Midwest Region

About this file

This document contains questions and answers regarding Solicitation #140P6324B0004 for improvements to the wastewater system at Fort Union Trading Post National Historical Park. The solicitation involves connecting approximately half of existing drain field chambers that are buried at a depth of 24 inches, with the contractor responsible for carefully excavating the ends of the drain field lines to expose and connect them. The government estimates this work will require two to three days using a backhoe and trenching approximately 24 square feet at each end. Spare LED indicator lights for a pump control panel should be provided as specified, with LED lights considered an equal alternative. The opportunity is for the Department of the Interior National Park Service Midwest Region for improvements to the wastewater system at Fort Union Trading Post NHS.

View the file

Other files for this federal contract opportunity

Other files attached to Fort Union Trading Post NHS Wastewater System Impr, newest first.
File Type Posted
Sol_140P6324B0004_Amd_0004.pdf PDF
Sol_140P6324B0004_Amd_0003.pdf PDF
B09_Amd_0003_Questions-Answers_140P6324B0004_3_8_24_0003.pdf PDF
Sol_140P6324B0004_Amd_0002.pdf PDF
B09_Amendment_002_Atch_1_Site_Visit_Sign_In_Sheet_FOUS_WW_Proj_0002.pdf PDF
B09_Amendment_001_Atch_2_Site_Visit_Sign_In_Sheet_FOUS_WW_Proj_0001.pdf PDF
Sol_140P6324B0004_Amd_0001.pdf PDF
Sol_140P6324B0004.pdf PDF
B08_Atch_1_SOW.pdf PDF
B08_Atch_2_SOW_Addendum_1.pdf PDF
B08_Atch_3_Drawings_Maps.pdf PDF
B08_Atch_4_DOL_Wage_Determination_ND20240044_1_5_24.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUS Water Waste System Improvement Ques�ons for Solicita�on # 140P6324B0004

Ques�on #1: If the sewer laterals that were previously installed are not visible, is the contractor responsible for exploratory excava�on as part of the bid or would this be a T&M change order? If it is to be part of the base contract, what bid item would you like it under for the schedule of values?

Answer: Approximately half of the drain field chambers have been installed. Depth of exis�ng chambers are at 24 inches and are iden�fied on the plans. The contractor will be responsible for carefully opening the ends of the drain field lines to expose them and �e them into the overall drain field system as show on the plan set. The contractor will be required to expose the ends (eight in total) to allow connec�on to the connector piping. The government es�mates the contractor will u�lize two to three days for digging work using a backhoe bucket where approximately 24 square feet per end trench will be needed. The government will provide addi�onal measurements and GPS readings (within 1-3 feet) taken of the exis�ng work prior to onsite work commencing. This work should be included in the contractor’s firm fixed price base contract lump sum bid. Connec�ng the exis�ng drain field chambers shall be under the “Drain Field with Insulated Manhole” schedule of values item details.

Ques�on #2: It is stated under Sec�on 16420 Submersible Grinder Pumps and Controls, 2.2 Pump Control Panel, O. Panel Indicator Lights, that 4 addi�onal bulbs for each size bulb used in the panel door is required. We use LED colored lights for our panel door indicator lights that have a long lifespan, htps://new.abb.com/products/1SFA611621R1042/mlbl-04g , will you s�ll require (4) bulbs of each size and color if LED is to be used instead? The top alarm light as it is an LED fixture, spec is calling for (2) spare bulbs, but these come as whole units and last for a very long �me as well.

Answer: Please provide spare bulbs as per specifica�on. LED lights will be considered “or equal”.