This is a Request for Information (RFI) Questions and Answers document for an OSB (Office/Building) Roof Replacement project. The document does not address specific response dates, award dates, pricing terms, or federal agency details, as it functions solely as a clarification mechanism for potential bidders.
The project involves replacing the roof membrane on an entire building with both upper and lower roof areas, using white EPDM membrane at manufacturer-required thickness to achieve a 30-year Non-Deterioration Limit (NDL) warranty. The existing roof deck consists of concrete/rubber substrate in good condition, with an approximate age of 30 years. Key specifications confirmed include: manufacturer-recommended ISO board layer count and installation methods; manufacturer-recommended taper design due to drainage requirements; field-fabricated metal coping as acceptable; and a fully adhered or mechanically fastened attachment system (not ballasted). The building is historic with architectural elements requiring protection during work. Roof access is available by window. As-built drawings and roof plans are not available for reference. The document confirms that unforeseen conditions not reasonably predictable qualify for contract modifications, and bidders should review the main solicitation for project budget information. Wind speed warranty requirements and specific architectural protections are addressed but require reference to the full solicitation for complete details.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P4526R0008_Amd_0003.pdf | ||
| 8b465c8e-8aea-45bb-be8a-6fd6c824dfef_0002.jpg | JPG image | |
| Sol_140P4526R0008_Amd_0002.pdf | ||
| aa711b1b-4c9c-4695-8d9e-bbe53b2a7421_0002.jpg | JPG image | |
| b127a134-faa1-453d-b394-59e79ccaba11_0002.jpg | JPG image | |
| SOW_ROOF_OSB_0002.pdf | ||
| Sol_140P4526R0008_Amd_0001.pdf | ||
| Clauses_construction.pdf | ||
| Sol_140P4526R0008.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFI Questions & Answers OSB Roof Replacement.
1. Is there a wind speed requirement for the warranty, or is it only the base wind speed associated with the 30-year NDL warranty? Yes
2. What is the material of the roof deck/substrate? Concrete/Rubber
3. Is the existing deck in good condition, or should we anticipate that a portion may need to be replaced? Concrete should be in good condition
4. Would unforeseen conditions that could not reasonably be predicted qualify as justification for a contract modification? Yes
5. Is new coping required? If so, is field-fabricated metal acceptable, or is manufacturer-supplied coping required? Yes, and Field Fabricated is acceptable
6. The membrane thickness for the white EPDM is not specified. Should we bid the manufacturer-required thickness necessary to achieve the 30-year NDL warranty? Yes
7. Please confirm whether both the upper and lower roof areas (the entire building) are to be replaced. YES
8. Are any as-built drawings or roof plans available for reference? No
9. Is there a specific taper requirement, or should we follow the manufacturer’s recommendation/design? Yes, because of drainage
10. Has a range of magnitude or preliminary budget been established for this project? Yes, review the solicitation.
11. Is there direct roof access (e.g., a roof hatch), or how is the roof typically accessed? Yes, by window
12. Do you know the approximate age of the existing roof system?
30 years old.
13. Is this a historic building? If so, are there any architectural elements or features that must be protected during the roof replacement that could be affected by the work? Yes, and Yes.
14. Is the new system intended to be ballasted, or attached using another method such as a fully adhered or mechanically fastened system? No, and Yes.
15. Should the ISO board layer count and installation method also follow the manufacturer’s recommendation? YES.