B09_Drawing E2_Amend3.pdf
PDF 60 KB Posted
- Attached to
- Construction Services for Sewer Line System Repair Federal contract opportunity
- Solicitation number
- 140P2020R0024
About this file
This document contains construction drawings and details for a sewer line system repair project at Mammoth Cave National Park. Key details include specifications for a modular support rack with a maximum equipment load of 200 lbs to be constructed of stainless steel strut and mounting hardware. Additional details provide trenching, conduit transition, and finish grade specifications.
The related federal contract opportunity is a solicitation issued by the Department of the Interior National Park Service seeking construction services for sewer line system repair at Mammoth Cave National Park. Services include repairs to the existing sewer line system to address deficiencies. The solicitation number is 140P2020R0024 and responses are due by May 29, 2020.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P2020R0024_Amd_0003.pdf | ||
| B09_Sol 140P2020R0024 SF30 Amd 0003.pdf | ||
| B09_Geotech Report_Amend3.pdf | ||
| E15_Deliverables_LmtOnSubconRpt.xlsx | XLSX spreadsheet | |
| B09_Q and A_Amend0003_140P2020R0024.pdf | ||
| B09_CLIN Sched_Amend3.pdf | ||
| Sol_140P2020R0024_Amd_0002.pdf | ||
| Sol 140P2020R0024 SF30 Amd 0001_0002.pdf | ||
| MACA 246490 O and M List_0002.pdf | ||
| Sol 140P2020R0024 SF30 Amd 0002_0002.pdf | ||
| MACA 246490 Submittal List_0002.pdf | ||
| Amendment 0001 Updated Drawings_0001.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
24" MINIMUM
AutoCAD SHX Text
24" MINIMUM
AutoCAD SHX Text NOTES: : 1. EQUIPMENT LOAD SHALL NOT EXCEED 200 LBS. EQUIPMENT LOAD SHALL NOT EXCEED 200 LBS. 2. RACK ASSEMBLY MATERIAL: STAINLESS STEEL STRUT AND MOUNTING HARDWARE. RACK ASSEMBLY MATERIAL: STAINLESS STEEL STRUT AND MOUNTING HARDWARE. 3. MODULAR STRUT WIDTH: 1 5/8". MODULAR STRUT WIDTH: 1 5/8". 4. PROTECT SURFACES WITH DISSIMILAR MATERIALS IN ACCORDANCE WITH SPECIFICATIONS. PROTECT SURFACES WITH DISSIMILAR MATERIALS IN ACCORDANCE WITH SPECIFICATIONS. 5. REPAIR CUT ENDS AND DAMAGED SURFACES IN ACCORDANCE WITH SPECIFICATIONS.REPAIR CUT ENDS AND DAMAGED SURFACES IN ACCORDANCE WITH SPECIFICATIONS.
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXTERIOR CONDUIT TRANSITION TO ABOVE GRADE DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TRENCHING DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MODULAR SUPPORT RACK DETAIL
AutoCAD SHX Text
FINISH GRADE
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
ELECTRICAL DETAILS
AutoCAD SHX Text
AutoCAD SHX Text 147,386
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
JBVT
AutoCAD SHX Text
JBVT
AutoCAD SHX Text
AutoCAD SHX Text 05-29-2020
AutoCAD SHX Text
MAMMOTH CAVE NATIONAL PARK
AutoCAD SHX Text 246490
AutoCAD SHX Text E2
File details come from the government source that posted it. Updated .